date: job number: sheet number · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens...
TRANSCRIPT
![Page 1: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/1.jpg)
LABEL
W2CF
RJ-45 SNAP-IN JACK
RJ-45 SNAP-IN JACK
LABEL
LABEL
RJ-45 SNAP-IN JACK
LABEL
LABEL
RJ-45 SNAP-IN JACK
RJ-45 SNAP-IN JACK
SINGLE GANG, 4 PORT
LABEL
RJ-45 SNAP-IN JACKRJ-45 SNAP-IN JACK
LABEL
LABEL
LABEL
LABEL
LABEL
RJ-45 SNAP-IN JACK
SINGLE GANG, 4 PORT
LABEL
LABEL
LABEL
RJ-45 SNAP-IN JACKRJ-45 SNAP-IN JACK
RJ-45 SNAP-IN JACK
RJ-45 SNAP-IN JACK
LABEL LABEL
LABEL LABEL
ANGLED JACK
ANGLED JACK
MUD RING
1 1/4" CONDUIT
5 SQ BOX
SIEMENS (BB 55B-03)
SERVICE LOOP
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS003
DATA PLAN DIAGRAMS
SCALE:ITS001
A
POS LOCATION
(ETHERSEAL FOR WET LOCATIONS)
NTS
(STAINLESS STEEL)
SCALE:ITS001
BWALL PHONE FACEPLATE
NTS SCALE:ITS001
C1 PORT FACEPLATE OUTLET
NTS SCALE:ITS001
D2 PORT ANGLED FACEPLATE OUTLET
NTS
SCALE:ITS001
E3 PORT ANGLED FACEPLATE OUTLET
NTS SCALE:ITS001
F4 PORT ANGLED FACEPLATE OUTLET
NTS SCALE:ITS001
G5 SQ BOX DETAIL
NTS
5 SQ DEEP J-BOX
W/ SINGLE GANG
PLASTER RING (18"
AFF UON), INSTALL
SOUND BARRIER
PADS BEHIND
BOXES
FINISHED FLOOR
FINISHED FLOOR
TELECOM OUTLET COVER PLATE
AND STANDARD WALL OUTLET.
1/4" (UON) EMT CONDUIT
CEILING
STUB CONDUIT INTO ACCESSIBLE
CEILING SPACE W/ NYLON
BUSHING. INSTALL J-HOOKS @
4'-0" OC FROM THIS POINT TO
ER/TR ROUGH-IN FOR FLOOR
OUTLETS AND MODULAR
FURNITURE OUTLETS SIMILAR.
SCALE:ITS001
HI.T.S. OUTLET BOX ROUGH-IN
NTS
4"x4" EX-PATH FIRE STOP
PATHWAY (UL CLASSIFIED
PER ASTM E814). PROVIDE
QTY OF PATHWAYS TO
ACCOMMODATE ALL
TELECOM CABLES PLUS
20% SPARE CAPACITY.
FIRE RATED,
SMOKE OR
ACOUSTICAL
WALL
SCALE:ITS001
JEZ-PATH FIRE STOP PATHWAY
NTS
WALL PLATE
TELECOM CABLE.
DO NOT EXCEED QTY (60)
CABLES PER 4"x4" PATHWAY
TELECOM CABLE
101-1-1 101-1-2 101-1-3
1 2 3
101-1-4
4
101-1-1
5
101-1-2
6
101-1-1 101-1-2 101-1-3
25 26 27
101-1-4
28
101-1-1
29
101-1-2
30
101-1-1 101-1-2
7 8
101-1-1 101-1-2
31 32
A
LASER PRINTED PATCH
PANEL PORT LABELS.
SEE TELECOMMUNICATIONS
LABELING AND SPECS FOR
REQUIREMENTS
SCALE:ITS001
K48 PORT PATCH PANEL
NTS
6"
3"
3"
3"
6"
6"
6"
3"
SCALE:ITS001
LTELECOM DUCT BANK DETAILS
NTS
YELLOW METALLIC
WARNIG TAPE (TYP
OF 2 - FULL LENGTH)
4" SCHED 40 PVC CONDUIT.
SEE SITE PLAN FOR SIZE
AND QTY
HARD-TAMPED SAND
SELECTED BACKFILL
COMPACTED TO 95%
DENSITY
UNDISTURBED SOIL
36"
UNDISTURBED SOIL
BACKFILL AND FINISH TO MATCH
EXISTING GRADE/SURFACE
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 2: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/2.jpg)
RACK LAYOUT IS FOR
DIAGRAMMATIC
PURPOSES ONLY
AV FIBER PATCH
PANEL IN DATA RACK
(LOCATION TBD)
3/4" AV CONDUIT
FOR FIBER
3/4" AV CONDUIT
FOR FIBER
OUTDOOR FIBER
TERMINATION FOR TV
TRUCK (LOCATION TBD)
AV WALL PLATE
FIBER CONNECTIVITY
3/4" AV CONDUIT
FOR FIBER
AV WALL PLATE
FIBER CONNECTIVITY
FLOOR BOX
1-1/2" AV CONDUIT
STUB TO ABOVE
ACCESSIBLE CEILING
(3) 4" ELECTRICAL PVC CONDUITS
WITH SWEEPING 90° BENDS
(3) 4" ELECTRICAL PVC CONDUITS
WITH SWEEPING 90° BENDS
( 2 ) 4 " E L E C T R I C A L P V C
CONDUITS STUB INTO RAISED
F L O O R I N G A M I N G A R E A
( 2 ) 4 " E L E C T R I C A L P V C
CONDUITS STUB INTO RAISED
F L O O R I N G A M I N G A R E A
(1) 1" ELECTRICAL PVC CONDUIT
TYPICAL OF EACH FLOOR BOX
LOCATIONS
TYPICAL FLOOR BOX
(LOCATION TBD)
( 3 ) 4 " EL ECTRI CAL PVC
C O N D U I T S E X T E N D T O
NEAREST GRASS AREA FOR
FUTURE HOTEL EXPANSION
(2) 4" CONDUITS UNDER SLAB RACEWAY
VESTIBULE
00
CU
LT
UR
E
00
A
CU
LT
UR
E
00
B
LOBBY
01
STORAGE
08
MARKETING
06
IDF
05
IDF OFFICE
04
VE
ST
IB
UL
E
03
PLAYERS
CLUB
07
VESTIBULE
103
CU
LT
UR
E
10
3B
CU
LT
UR
E
10
3A
MENS
90
WOMENS
92
BALLROOM
96
BANQUET
CORRIDOR
97
BREAK OUT
93
BREAK OUT
94
BREAK OUT
95
CONFERENCE
28
MENS
24
WOMENS
22
MENS VEST
23
WOMENS VEST
20
EVS
21
BEVERAGE
STATION
19
SUPERVISOR
OFFICE
37
TRAP
38
CART
39
CAGE
MANAGER
44
OPERATION
MANAGER
30
STO
29
GENERAL
MANAGER
31
MOD
32
EVS
STORAGE
33
FIRE RISER
34
EMERGENCY
ELECTRICAL
35
ELECTRICAL
CO
RR
ID
OR
26
CORRIDOR
26
FJP
25
BANQUET
STORAGE
99
BANQUET
FOOD
PREPARATION
98
PREFUNCTION
89
EV
S
90
A
EV
S
92
A
OFFICE
98A
EVS
98B
WALKIN
C01
COOLER
C02
COOLER
C02
GAMING
02
ELEC.
97A
IDF
27
AREA-1 AREA-2
MA
TC
H LIN
EM
AT
CH
LIN
E
1/16" = 1'-0"
LOW VOLTAGE CONDUIT PLAN
CONDUIT IN FLOOR OR BELOW GRADE
CONDUIT IN WALL OR ABOVE CEILING
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02
(100% SET)
03/27/18 17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
ITS004A
LOW VOLTAGE
CONDUIT PLAN
AREA 1
1 4/5/2018 UNDER SLAB CONDUIT
2 5/22/2018 ADDENDUM #10
1
1
2
2
2
![Page 3: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/3.jpg)
RACK LAYOUT IS FOR
DIAGRAMMATIC
PURPOSES ONLY
AV FIBER PATCH
PANEL IN DATA RACK
(LOCATION TBD)
3/4" AV CONDUIT
FOR FIBER
2" AV CONDUIT
UNDER SLAB
4x4 JUNCTION BOX
RACK LAYOUT IS FOR
DIAGRAMMATIC
PURPOSES ONLY
3/4" AV CONDUIT
UNDER SLAB
STUB CONDUIT ABOVE
ACCESSIBLE CEILING
( 4 ) 4 " E L E C T R I C A L P V C
CONDUITS WITH SWEEPING
90° BENDS STUB INTO RAISED
F L O O R I N G A M I N G A R E A
( 4 ) 4 " EL EC T RI CA L
PVC CONDUITS WITH
SWEEPING 90° BENDS
( 2 ) 4 " E L E C T R I C A L P V C
CONDUITS STUB INTO RAISED
F L O O R I N G A M I N G A R E A
4x4 JUNCTION
BOX
1" CONDUIT
UNDER SLAB
FLOOR BOX
1-1/2" AV CONDUIT STUB TO
ABOVE ACCESSIBLE CEILING
FLOOR BOX
1-1/2" AV CONDUIT STUB TO
ABOVE ACCESSIBLE CEILING
VESTIBULE
00
CU
LT
UR
E
00
A
CU
LT
UR
E
00
B
LOBBY
01
MENS VEST
10
WOMENS
VEST
14
EVS
STORAGE
12
MENS
11
WOMENS
13
BEVERAGE
STATION
19
SUPERVISOR
OFFICE
37
TRAP
38
CART
39
CAGE
MANAGER
44
VAULT
40
MAIN CAGE
41
DROP AND
ISSUE
42
SHIFT
SUPERVISOR
47
CASHIER
OFFICE
48
STO
42A
FIRE RISER
34
EMERGENCY
ELECTRICAL
35
ELECTRICAL
36
REVENUE
AUDIT
46
AUDIT
45
SU
RV
EIL
LA
NC
E
MA
NA
GE
R
55
STO
58
L&F
57
SECURITY
OFFICE
56
SECURITY
SUPERVISOR
59
OFFICE
62
WAITING
61
KEY
65
OFFICE
63
OFFICE
64
HOLDING
66
SLOT
MAINTENANCE
67
TRASH
68
RECIEVING
69
EVS
79B
IDF
70
TOILET
82
OFFICE
80
GAMING
COMMISSION
71
SECURED
STORAGE
69A
EDR
72
CORRIDOR
26
GREEN
54
STAIR
53
MDF
52
VIEWING
49
CSA
50
SURVEILLANCE
51
CORRIDOR
26
BEVERAGE
STATION
09
WAITING
86
BAR
85
PRIVATE
DINING
83
GRAB AND
GO
15
LOUNGE
16
BAR
17
SERVING
STATION
18
BOH
VESTIBULE
60
MENS
73
WOMENS
74
KITCHEN
75
VIP EVENT
76
KITCHEN
79
OFFICE
78
DRY
STORAGE
77
TOILET
87
TOILET
88
CONNECTION
VESTIBULE
102
CU
LT
UR
E
10
2A
CU
LT
UR
E
10
2B
DINING
84A
DRY
STORAGE
79A
COOLER
C04
COOLER
C04
ELECTRICAL
97C
COOLER
C03
CASHIER
43
COOLER
C05
COOLER
C05
GAMING
02
OPEN AREA
61A
FILE
61B
DINING
84
ICE
17A
BAR
STORAGE
100
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02
(100% SET)
03/27/18 17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
ITS004B
LOW VOLTAGE
CONDUIT PLAN
AREA 2
1 4/5/2018 UNDER SLAB CONDUIT
2 5/22/2018 ADDENDUM #10
AREA-1 AREA-2
MA
TC
H LIN
EM
AT
CH
LIN
E
1/16" = 1'-0"
LOW VOLTAGE CONDUIT PLAN
CONDUIT IN FLOOR OR BELOW GRADE
CONDUIT IN WALL OR ABOVE CEILING
1
1
1
2
![Page 4: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/4.jpg)
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS200A
OVERVIEW PLAN
RAISED FLOOR
PATHWAYS
52
MDF
27
IDF
05
IDF
70
IDF
(2) 4" CONDUITS
UNDER SLAB
RACEWAY
GENERAL NOTES
1. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
2. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
3. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
4. ALL CABLING PATHWAYS SHALL BE INSTALLED AS RECOMMENDED BY THE
MANUFACTURER AND BEST INDUSTRY STANDARDS AND PRACTICES TO PROPERLY
SUPPORT THE CABLE DENSITY, ENSURE THE CABLE BEND RADIUS IS NOT EXCEEDED,
AND TO PREVENT COMPROMISING THE INTEGRITY OF EVERY CABLE IN SUCH
PATHWAY.
5. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
6. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
7. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNER'S REPRESENTATIVE
AT THE CONCLUSION OF THE PROJECT.
8. PROVIDE FIRE STOPPING AS REQUIRED BY CODE FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM PROVIDE DRAWINGS
AND PERMITS AS REQUIRED.
9. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
10. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TR
LOCATIONS. UTILIZE STI RADIUS DROPS INTO TR PATHWAYS.
11. ALL FIBER BETWEEN ER AND TR SHALL BE TERMINATED WITH PANDUIT LC
CONNECTORS AND LANDED IN 12 PORT LC MODULES.
KEYED NOTES
PROVIDE AND INSTALL 2"x18" BASKET TRAY (#WBT2x18S) BETWEEN SUPPORTS IN THERAISED FLOOR AREA. USE WBT CONNECTORS, SUPPORTS, ETC. AS RECOMMENDED BYMANUFACTURE.
FLOOR DUCT PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, REFERELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.
PROVIDE AND INSTALL HILTI SLEEVE TO PENETRATE ER / TR WALL IN RAISED FLOOR.
PROVIDE AND INSTALL 1" INNER DUCT WITH TWO (2) TYPE 13 FIBER AND ONE (1) TYPE14 FIBER BETWEEN MDF 52 AND IDF 05,27,70. RUN IN BASKET TRAY.
PROVIDE AND INSTALL TWO (2) TYPE 15 CABLE BETWEEN MDF 52 AND IDF 05,27,70.LAND ON RACK MOUNTED PUNCH BLOCK AS SHOWN ON ITS-300 AND ITS302.
1
2
3
4
5
1113
1
1
1
3
22
6"
2"x4" WBT TRAY
(SURVEILLANCE / AV)
2"x8" WBT TRAY
(DATA)
CONDUIT
BRACKET
WALL SUPPORT OR ALL
THREAD SUPPORT
SCALE:ITS200A
AOVERVIEW PLAN - RAISED FLOOR PATHWAYS
1"-20'-0"
SCALE:ITS200A
BWBT BASKET TRAY
NTS
4
5
4 5
4 5
4
5
1 1
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 5: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/5.jpg)
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS200B
OVERVIEW PLAN
CEILING PATHWAYS
SCALE:
OVERVIEW PLAN - CEILING PATHWAYS
1"=20"-0"
1
GENERAL NOTES
1. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT,CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
2. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
3. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
4. ALL CABLING PATHWAYS SHALL BE INSTALLED AS RECOMMENDED BY THE
MANUFACTURER AND BEST INDUSTRY STANDARDS AND PRACTICES TO PROPERLY
SUPPORT THE CABLE DENSITY, ENSURE THE CABLE BEND RADIUS IS NOT EXCEEDED,
AND TO PREVENT COMPROMISING THE INTEGRITY OF EVERY CABLE IN SUCH
PATHWAY.
5. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
6. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
7. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNER'S REPRESENTATIVE
AT THE CONCLUSION OF THE PROJECT.
8. PROVIDE FIRE STOPPING AS REQUIRED BY CODE FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM PROVIDE DRAWINGS
AND PERMITS AS REQUIRED.
9. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
10. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TR
LOCATIONS. UTILIZE STI RADIUS DROPS INTO TR PATHWAYS.
11. USE WBT SUPPORTS, CONNECTORS, DIVIDER TRAY INSERTS, TEES, RADIUS' EXITS &
DOWNS, DROP OUTS AS REQUIRED BY DESIGN.
KEYED NOTES
PROVIDE AND INSTALL 2"x8" BASKET TRAY (#WBT2x8S) ABOVE CEILING FOR ROUTINGOF WIFI AND SURVEILLANCE DATA CABLES AS SHOWN. ALL PATHWAYS TO BEPROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
ALL CEILING MOUNTED BASKET TRAY TO HAVE TRAY INSERT 4(BL) INSTALLED INBOTTOM OFF ALL BASKET TRAY PATHWAYS. USE WBT CONNECTORS, MOUNTINGBRACKETS, RADIUS, TEE, SUPPORTS, RADIUS EXIT, BLIND ENDS.
1
2
52
MDF
27
IDF
05
IDF
70
IDF
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 6: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/6.jpg)
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAPWAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP WAP
WAP
WAP
WAP
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS200C
WAP OVERVIEW PLAN
SCALE:
WAP OVERVIEW PLAN
1"=20"-0"
1
GENERAL NOTES
1. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
2. WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE PATCH PANELS IN
ER/TR/TC ROOMS.
3. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT. LOOP SHALL BE THE PROPER SIZE FOR THE AMOUNT OF CABLES
WITHIN. NO BUNDLE SHALL HAVE MORE THAN 24 CABLES.
4. PROVIDE ALL SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHING PRIOR TO
PULLING CABLE.
5. LABEL ALL WAP CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
6. CONTRACTOR SHALL ROUTE WIRELESS, DATA AND CCTV CABLES IN THE SAME BASKET
TRAY, SLEEVES OR CONDUIT BACK TO THE APPROPRIATE ER/TR/TC ROOM.
7. COIL 10' OF SPATE CAT 6 DATA CABLING AT EVERY WAP LOCATION USING ARLINGTON
LOOPS FOR FINAL WAP INSTALLATION.
8. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNER'S REPRESENTATIVE
AT THE CONCLUSION OF THE PROJECT.
9. PROVIDE FIRE STOPPING AS REQUIRED BY CODE FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM PROVIDE DRAWINGS
AND PERMITS AS REQUIRED.
10. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT IN BACKET TRAY LOCATIONS. NO SPACING BETWEEN LOOPS SHALL
EXCEED 4'. NO CABLE SHALL DROOP MORE THAN 6” OR TOUCH OTHER SYSTEM
CABLES, PIPES, DUCTS, OR CEILING SUPPORTS. THERE SHALL BE A MINIMUM
SEPARATION OF 6” BETWEEN LIGHT FIXTURES AND ELECTRICAL SOURCES.
11. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
12. NO CABLES SHALL BE INSTALLED PRIOR TO ANY CEILING PAINTING. DATA CABLES ARE
NOT TO BE PAINTED. ANY PAINT, OVER SPRAY OR BRUSH MARKS ARE TO BE REMOVED
PRIOR TO TESTING AND CERTIFICATION.
13. ALL HORIZONTAL CABLE SYSTEMS SHALL COME WITH AN EXTENDED MANUFACTURERS
WARRANTY. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL
HORIZONTAL COPPER CABLES USING PERMANENT LINK METHOD. TEST TO BE
PERFORMED WITH A MANUFACTURE APPROVED TESTER TO THEIR SPECIFICATIONS
AND STANDARDS. NOTE: FLUKE *DTX-1800 IS THE PREFERRED TESTER. PROVIDE
OWNERS REPRESENTATIVE COPIES OF ALL TEST RESULTS SUBMITTED TO
MANUFACTURER IN RAW TESTER FORMAT.
14. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
52
MDF
27
IDF
05
IDF
70
IDF
KEYED NOTES
PROVIDE AND INSTALL TWO (2) TYPE 2 CABLES, BLACK IN COLOR, TO EACH WIRELESSACCESS POINT OUTLET BOX IN CEILING. TERMINATE INTO A 2-PORT SURFACE MOUNTBOX WITH CAT6A MODULE JACKS.
1
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 7: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/7.jpg)
BANQUET
CORRIDOR
97
IDF
27
BREAK OUT
95
CONFERENCE
28
MENS
24
WOMENS
22
OPERATION
MANAGER
30
STO
29
GENERAL
MANAGER
31
MOD
32
EVS
STORAGE
33
26
CORRIDOR
26
FJP
25
BANQUET
STORAGE
99
BANQUET
FOOD
PREPERATION
98
OFFICE
98A
EVS
98B
WALKIN
C01
COOLER
C02
COOLER
C02
TV
1D
+84"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
C
C
C
C
C
C C
C
C
C
C
C
C
C
C
C
C
C
C
WAP
WAP
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
F
F
2D
2
ES
+54"
2D
1D/1AV 1D/1AV
1D/1AV1D/1AV
TV
1D/1AV
+72"
PS
PS
PS
PS
3D/1AV 3D/1AV3D/1AV
3D/1AV
3D/1AV
3D/1AV
3D/1AV
3D/1AV
2D
2D
2D
4D
4D
2D2D
2D
2D 2D
2D
2D
2D
2D
2D
2D
4D
4D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS201
DATA PLAN - AREA 1
MATCH LINE MATCH LINE
MA
TC
H LIN
EM
AT
CH
LIN
E
AREA-5
AREA-4
AREA-3
AREA-1
AREA-2
SCALE:
DATA PLAN - AREA 1
1/8" = 1'-0"
1
GENERAL NOTES
1. REFER TO THE ITS DIAGRAM SHEETS FOR COVER PLATE LAYOUTS AND ADDITIONAL
INFORMATION.
2. SEE CABLE MATRIX ON ITS COVER SHEET FOR CABLE TYPES AND PART NUMBERS.
3. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
PROVIDE AN INSTALL DYMO #18055 SHRINK TUBE LABELS, 2” FROM MODULAR PLUG ON
BOTH ENDS.
4. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
5. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
6. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT. LOOP SHALL BE OF PROPER SIZE FOR THE AMOUNT OF CABLE
WITHIN. NO BUNDLE SHALL HAVE MORE THAN 24 CABLES.
7. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
8. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT IN BACKET TRAY LOCATIONS. NO SPACING BETWEEN LOOPS SHALL
EXCEED 4'. NO CABLE SHALL DROOP MORE THAN 6” OR TOUCH OTHER SYSTEM
CABLES, PIPES, DUCTS, OR CEILING SUPPORTS. THERE SHALL BE A MINIMUM
SEPARATION OF 6” BETWEEN LIGHT FIXTURES AND ELECTRICAL SOURCES.
9. NO MORE THAN 6” SERVICE LOOP MAY BE STORED IN OUTLET BOX LOCATION. A 10'
SERVICE LOOP SHALL BE ROLLED, COILED AND STORED IN THE CEILING CAVITY ABOVE
EACH DROP LOCATION. UTILIZE PROPER CABLE SUPPORT WITH VELCRO WRAP TO
HOLD IN PLACE.
10. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
11. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION OF ALL OUTLETS MOUNTED
ADJACENT TO ELECTRICAL OUTLETS IN WALLS OR CASEWORK PRIOR TO ROUGH-IN.
12. PROVIDE A SIEMON 5 SQUARE, EXTRA DEEP, JUNCTION BOX WITH (1) 1” KNOCKOUT
AND (1) 1/4" KNOCKOUT WITH MUD RING TO REDUCE TO A SINGLE GANG FACEPLATE.
INSTALL EITHER A 1” OR 1-1/4” CONDUIT AS REQUIRED TO CEILING SPACE WITH
SMOOTH THROAT CONNECTOR AND NYLON BUSHING FOR ALL DATA/VOICE CAT 6
OUTLETS. REFER TO THE ITS DIAGRAM SHEETS FOR FACEPLATE CONFIGURATIONS
AND ADDITIONAL INFORMATION.
13. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
14. NO CABLES SHALL BE INSTALLED PRIOR TO ANY CEILING PAINTING. DATA CABLES ARE
NOT TO BE PAINTED. ANY PAINT, OVER SPRAY OR BRUSH MARKS ARE TO BE REMOVED
PRIOR TO TESTING AND CERTIFICATION.
15. ALL HORIZONTAL CABLE SYSTEMS SHALL COME WITH AN EXTENDED MANUFACTURERS
WARRANTY. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL
HORIZONTAL COPPER CABLES USING PERMANENT LINK METHOD. TEST TO BE
PERFORMED WITH A MANUFACTURE APPROVED TESTER TO THEIR SPECIFICATIONS
AND STANDARDS. NOTE: FLUKE *DTX-1800 IS THE PREFERRED TESTER. PROVIDE
OWNERS REPRESENTATIVE COPIES OF ALL TEST RESULTS SUBMITTED TO
MANUFACTURER IN RAW TESTER FORMAT.
16. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
17. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ATIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
18. FIBER CABLING SHALL BE INSTALLED IN ACCORDANCE WITH 2008 NEC ARTICLE 770.
KEYED NOTES
GAMING FLOOR DATA: PROVIDE TYPE 3 PLENUM RATED UTP BLUE CABLES WITH RJ45JACKS. LAND RJ45 MODULAR JACK IN SURFACE MOUNT BOX. PROVIDE NUMBER OFCABLES AS INDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS AS NEEDEDTO ACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
GAMING FLOOR BOX DATA LOCATIONS: PROVIDE TYPE 3 PLENUM RATED UTP BLUECABLES WITH RJ45 JACKS, FACEPLATES, RECESSED FLOOR BOX PROVIDED BYELECTRICAL CONTRACTOR, 1" PVC/CONDUIT STUB ABOVE CEILING. PROVIDE NUMBEROF CABLES AS INDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS ASNEEDED TO ACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
WALL PHONE LOCATIONS: PROVIDE ONE (1) TYPE 1 PLENUM RATED UTP BLUE CABLEWITH ONE (1) RJ45 JACK, BLANK MODULE, 2-PORT FACEPLATE MOUNTED AT +42" AFF,UON.
DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLE WITH RJ45 JACKS,FACEPLATES, MOUNTED AT +18" AFF, UON. 4S J-BOX WITH SINGLE GANG MUD RING,3/4" CONDUIT STUB ABOVE CEILING, ROUTE OVER J-HOOKS TO NEAREST MDF/IDF.PROVIDE NUMBER OF CABLES AS INDICATED ON THE PLAN. PROVIDE FACEPLATES ANDBLANKS AS NEEDED TO ACCOMMODATE NUMBER OF CABLE DROPS AT EACHLOCATION.
TV DATA LOCATIONS: PROVIDE ONE (1) TYPE 3 PLENUM RATED UTP BLUE CABLE WITHONE (1) RJ45 JACK, 2-PORT FACEPLATE, BLANK MODULE, MOUNTED AT +60" AFF, UON.4S J-BOX WITH SINGLE GANG MUD RING, 3/4" CONDUIT STUB ABOVE CEILING, ROUTEOVER J-HOOKS TO NEAREST MDF/IDF.
ATM DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLES WITH RJ45JACKS, FACEPLATES, BLANK MODULE, MOUNTED AT +18" AFF, UON. PROVIDE NUMBEROF CABLES AS INDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS ASNEEDED TO ACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
POS DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLES WITH RJ45JACKS, FACEPLATES, BLANK MODULE. COORDINATE WITH MILLWORK CONTRACTORFOR PLACEMENT. PROVIDE NUMBER OF CABLES AS INDICATED ON THE PLAN.PROVIDE FACEPLATES AND BLANKS AS NEEDED TO ACCOMMODATE NUMBER OF CABLEDROPS AT EACH LOCATION.
FLOOR BOX DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLE WITHRJ45 JACKS, FACEPLATES, RECESSED FLOOR BOX PROVIDED BY ELECTRICALCONTRACTOR, 1" PVC/CONDUIT STUB ABOVE CEILING. PROVIDE NUMBER OF CABLESAS INDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS AS NEEDED TOACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
IN COUNTER DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLESWITH RJ45 JACKS, FACEPLATES. COORDINATE WITH MILLWORK CONTRACTOR FORPLACEMENT. PROVIDE NUMBER OF CABLES AS INDICATED ON THE PLAN. PROVIDEFACEPLATES AND BLANKS AS NEEDED TO ACCOMMODATE NUMBER OF CABLE DROPSAT EACH LOCATION.
ABOVE COUNTER DATA LOCATIONS: PROVIDE TYPE 1 PLENUM RATED UTP BLUECALBES WITH RJ45 JACKS, FACEPLATES. COORDINATE WITH MILLWORK CONTRACTORFOR PLACEMENT. WALL MOUNT AT +42" AFF, UON. PROVIDE NUMBER OF CABLES ASINDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS AS NEEDED TOACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
CAMERA DATA LOCATIONS: PROVIDE ONE (1) TYPE 4 CABLE TO ALL CAMERALOCATIONS. OWNER TO INSTALL ALL CAMERAS. LEAVE 10' SERVICE LOOP, COILED ANDVELCRO'D ABOVE CAMERA LOCATION AND CABLE TRAY.
FLOOR BOX DATA AND AV LOCATIONS: PROVIDE TYPE 1 (DATA) PLENUM RATED UTPBLUE CABLE AND TYPE 2 (AV) SHIELDED PLENUM RATED UTP BLACK CABLE WITH RJ45JACKS, FACEPLATES, RECESSED FLOOR BOX PROVIDED BY ELECTRICAL CONTRACTOR, 1"PVC/CONDUIT STUB ABOVE CEILING. PROVIDE NUMBER OF CABLES AS INDICATED ONTHE PLAN. PROVIDE FACEPLATES AND BLANKS AS NEEDED TO ACCOMMODATENUMBER OF CABLE DROPS AT EACH LOCATION.
TOUCH PANEL DATA LOCATIONS: PROVIDE ONE (1) TYPE 1 PLENUM RATED UTP BLUECABLE WITH ONE (1) RJ45 JACK, BLANK MODULE, 2-PORT FACEPLATE MOUNTED AT+42" AFF, UON.
ELECTRONIC MEETING SIGN DATA LOCATIONS: PROVIDE TWO (2) TYPE 1 PLENUMRATED UTP BLUE CABLE WITH TWO (2) RJ45 JACK, BLANK MODULE, 2-PORT FACEPLATEMOUNTED AT +42" AFF, UON.
PROJECTOR DATA AND AV LOCATIONS: PROVIDE ONE (1) TYPE 1 (DATA) PLENUMRATED UTP BLUE CABLE AND ONE (1) TYPE 2 (AV) SHIELDED PLENUM RATED UTP BLACKCABLE WITH RJ45 JACKS, FACEPLATES.
LED DATA LOCATIONS: PROVIDE ONE (1) TYPE 1 PLENUM RATED UTP BLUE CABLE WITHONE (1) RJ45 JACK, BLANK MODULE, 2-PORT FACEPLATE.
TV DATA AND AV LOCATIONS: PROVIDE ONE (1) TYPE 1 (DATA) PLENUM RATED UTPBLUE CABLE AND ONE (1) TYPE 2 (AV) SHIELDED PLENUM RATED UTP BLACK CABLEWITH RJ45 JACKS, FACEPLATES.
VIDEO WALL DATA LOCATION: PROVIDE TYPE 1 PLENUM RATED UTP BLUE CABLE WITHRJ45 JACKS, FACEPLATES. 4S J-BOX WITH SINGLE GANG MUD RING, 3/4" CONDUITSTUB ABOVE CEILING, ROUTE OVER J-HOOKS TO NEAREST MDF/IDF. PROVIDE NUMBEROF CABLES AS INDICATED ON THE PLAN. PROVIDE FACEPLATES AND BLANKS ASNEEDED TO ACCOMMODATE NUMBER OF CABLE DROPS AT EACH LOCATION.
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
12
3
1212
13
15
14
11
8
4
15
13
12
4
14
11
11
4
8
5
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 8: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/8.jpg)
STORAGE
08
MARKETING
06
IDF
05
IDF OFFICE
04
TRAP
03
PLAYERS
CLUB
07
VESTIBULE
103
CU
LT
UR
E
88B
CU
LT
UR
E
88A
MENS
90
WOMENS
92
BALLROOM
96
BREAK OUT
93
BREAK OUT
94
BREAK OUT
95
MENS
24
WOMENS
22
MENS VEST
23
WOMENS
VEST
20
EV
S
21
CORRIDOR
26
FJP
25
PREFUNCTION
89
EVS
91
EVS
93
TP
1D
+54"
TP
1D
+54"
TP
1D
TP
1D
+54"
TV
1D
+120"
TV
1D
+120"
TV
1D
+120"
TV
1D
+120"
TV
1D
+84"
TV
1D
+84"
TV
1D
TV
1D
TV
1D
+84"
TV
1D
+84"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
TV
1D
EC
TV
1D
EC
TV
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
4D
5D5D4D
4D5D
4D
5D4D4D
4D4D
4D
4D
5D
6D
5D
4D
4D
4D
4D
4D
5D
5D
4D
5D
5D
4D4D
4D
4D 4D
4D
WAP
WAP
WAP
WAP
WAPWAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
4D
C
C C
C
C
C
C
C
C
CC
C
C
C
C
C
C C
C
C
C
C
C
CC
CC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
2D
4D
4D
4D
3D
2D
F
1D
EC
POS
2D 2D
2D 2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
1D/1AV 1D/1AV
1D/1AV1D/1AV
TV
1D/1AV
+72"
4D4D
PS
PS PS
PS
3D/1AV
3D/1AV
3D/1AV 3D/1AV 3D/1AV 3D/1AV
3D/1AV
3D/1AV
3D/1AV
3D/1AV
3D/1AV
1D
LED
1D
LED
1D
LED
1D
LED
1AV
2D
TV
1D/1AV
+72"
1AV
2D
1AV
2D
4D
4D
2D
2D2D
TP
1D
+54"
2D
2D
2D
2D 2D
2D
2D
2D
2D
2D 2D
2D 2D
2D
2D
4D4D
4D
4D
4D
4D
4D
4D
4D
4D
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
ES
+54"
2D
TV
1D/1AV
+72"
TV
1D
+120"
MATCH LINE MATCH LINE
MA
TC
H LIN
EM
AT
CH
LIN
E
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS202
DATA PLAN - AREA 2
AREA-5
AREA-4
AREA-3
AREA-1
AREA-2
SCALE:
DATA PLAN - AREA 2
1/8" = 1'-0"
1
REFER TO SHEET ITS201 FOR KEYED NOTES.
10
5
11
5
104
7
1
2
5
11
1
13
5
1
2
17
4
12
11
13
12
17
14
5
16
4
14
13
15
12
8
15
13
4
1212
5
11
14
16
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 9: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/9.jpg)
VESTIBULE
00
CU
LT
UR
E
00
A
CU
LT
UR
E
00
B
LOBBY
01
STORAGE
08
MARKETING
PLAYERS
MENS VEST
10
WOMENS
VEST
14
EVS
STORAGE
12
MENS
11
WOMENS
13
WOMENS
22
WOMENS
VEST
20
BEVERAGE
STATION
19
SUPERVISOR
OFFICE
37
TRAP
38
CART
39
CAGE
MANAGER
44
VAULT
40
MAIN CAGE
41
DROP AND
ISSUE
42
SHIFT
SUPERVISOR
47
CASHIER
OFFICE
48
STO
42A
EVS
STORAGE
33
FIRE RISER
34
EMERGENCY
ELECTRICAL
35
ELECTRICAL
36
REVENUE
AUDIT
46
AUDIT
45
SURVEILLANCE
MANAGER
55
STO
58
L&F
57
SECURITY
OFFICE
56
BAR
STORAGE
100
GREEN
54
STAIR
53
MDF
52
VIEWING
49
CSA
50
SURVEILLANCE
51
CORRIDOR
26
CORRIDOR
26
BEVERAGE
STATION
09
GRAB AND
GO
15
LOUNGE
16
BAR
17
SERVING
STATION
18
CASHIER
43
STORAGE
GAMING
02
(BELOW STAGE)
TP
1D
+54"
TV
1D
+120"
TV
1D
+120"
TV
1D
TV
COAX
TV
1D
+120"
TV
1D
+120"
TV
1D
+84"
TV
1D
+84"
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
EC
TV
1D
+120"
TV
1D
+120"
4D
4D
4D
5D4D5D
4D
4D
4D
4D
4D5D4D
4D
6D 6D
4D
4D4D5D
5D
5D
4D
4D5D 5D4D 4D
4D5D 4D4D 4D
6D
4D
4D
4D
5D
4D 4D
5D
4D4D
4D 4D
WAP
WAP
WAP
WAP
WAP
WAP
WAP
4D
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CCC
C
CCCC C C
CCCC
C
C
C
C
C
C
C C
C
C
C
C
C
C
C
WAP
1D
2D
2D
ATM
2D
2D
POS
2D
POS
2D
POS
3D
2D
2D
2D
2D 2D
2D
4D
2D2D2D2D
2D
2D
2D 2D 2D
2D 2D 2D 2D
2D
2D
2D
2D
2D
2D
2D2D
2D
2D
2D
2D2D
2D2D2D
2D
2D2D
2D 1D
2D
2D
2D
2D
2D
2D
2D
2D
4D
4D
3D
2D
2D
2D
3D
3D
2D
3D 2D
1D
EC
POS
4D
VW
+120"
EC
POS
4D
VW
+120"
2D
2D
KRONOS CLOCK
4D
4D
65"
42" 42"
42" 42"
1D
LED
1D
LED
1D
LED
1D
LED
4D4D
4D4D
4D
4D4D
4D
TV
1D
+120"
TV
1D
+120"
MA
TC
H LIN
E
MA
TC
H LIN
E
MA
TC
H LIN
E
MA
TC
H LIN
E
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS203
DATA PLAN - AREA 3
AREA-5
AREA-4
AREA-3
AREA-1
AREA-2
SCALE:
DATA PLAN - AREA 3
1/8" = 1'-0"
1
GENERAL NOTES
1. REFER TO THE ITS DIAGRAM SHEETS FOR COVER PLATE LAYOUTS AND ADDITIONAL
INFORMATION.
2. SEE CABLE MATRIX ON ITS COVER SHEET FOR CABLE TYPES AND PART NUMBERS.
3. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
PROVIDE AN INSTALL DYMO #18055 SHRINK TUBE LABELS, 2” FROM MODULAR PLUG ON
BOTH ENDS.
4. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
5. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
6. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT. LOOP SHALL BE OF PROPER SIZE FOR THE AMOUNT OF CABLE
WITHIN. NO BUNDLE SHALL HAVE MORE THAN 24 CABLES.
7. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
8. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT IN BACKET TRAY LOCATIONS. NO SPACING BETWEEN LOOPS SHALL
EXCEED 4'. NO CABLE SHALL DROOP MORE THAN 6” OR TOUCH OTHER SYSTEM
CABLES, PIPES, DUCTS, OR CEILING SUPPORTS. THERE SHALL BE A MINIMUM
SEPARATION OF 6” BETWEEN LIGHT FIXTURES AND ELECTRICAL SOURCES.
9. NO MORE THAN 6” SERVICE LOOP MAY BE STORED IN OUTLET BOX LOCATION. A 10'
SERVICE LOOP SHALL BE ROLLED, COILED AND STORED IN THE CEILING CAVITY ABOVE
EACH DROP LOCATION. UTILIZE PROPER CABLE SUPPORT WITH VELCRO WRAP TO
HOLD IN PLACE.
10. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
11. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION OF ALL OUTLETS MOUNTED
ADJACENT TO ELECTRICAL OUTLETS IN WALLS OR CASEWORK PRIOR TO ROUGH-IN.
12. PROVIDE A SIEMON 5 SQUARE, EXTRA DEEP, JUNCTION BOX WITH (1) 1” KNOCKOUT
AND (1) 1/4" KNOCKOUT WITH MUD RING TO REDUCE TO A SINGLE GANG FACEPLATE.
INSTALL EITHER A 1” OR 1-1/4” CONDUIT AS REQUIRED TO CEILING SPACE WITH
SMOOTH THROAT CONNECTOR AND NYLON BUSHING FOR ALL DATA/VOICE CAT 6
OUTLETS. REFER TO THE ITS DIAGRAM SHEETS FOR FACEPLATE CONFIGURATIONS
AND ADDITIONAL INFORMATION.
13. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
14. NO CABLES SHALL BE INSTALLED PRIOR TO ANY CEILING PAINTING. DATA CABLES ARE
NOT TO BE PAINTED. ANY PAINT, OVER SPRAY OR BRUSH MARKS ARE TO BE REMOVED
PRIOR TO TESTING AND CERTIFICATION.
15. ALL HORIZONTAL CABLE SYSTEMS SHALL COME WITH AN EXTENDED MANUFACTURERS
WARRANTY. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL
HORIZONTAL COPPER CABLES USING PERMANENT LINK METHOD. TEST TO BE
PERFORMED WITH A MANUFACTURE APPROVED TESTER TO THEIR SPECIFICATIONS
AND STANDARDS. NOTE: FLUKE *DTX-1800 IS THE PREFERRED TESTER. PROVIDE
OWNERS REPRESENTATIVE COPIES OF ALL TEST RESULTS SUBMITTED TO
MANUFACTURER IN RAW TESTER FORMAT.
16. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
17. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ATIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
18. FIBER CABLING SHALL BE INSTALLED IN ACCORDANCE WITH 2008 NEC ARTICLE 770.
REFER TO SHEET ITS201 FOR KEYED NOTES.
3
5
1
3
10
1010
11
10 10 10
10
4
1010
5
5
11
18
18
1
17
UNDER COUNTER
11
6
1
2
5
1616
5
16
1
5
1
2
11
1
2
5
4
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 10: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/10.jpg)
SURVEILLANCE
MANAGER
55
STO
58
L&F
57
SECURITY
OFFICE
56
SECURITY
SUPERVISOR
59
WAITING
61
KEY
65
OFFICE
64
HOLDING
66
SLOT
MAINTENANCE
67
TRASH
68
RECIEVING
69
EVS
79B
IDF
70
TOILET
82
OFFICE
80
SECURED
STORAGE
69A
EDR
72
CORRIDOR
26
BAR
STORAGE
100
GREEN
54
STAIR
53
PRIVATE
DINING
83
BOH
VESTIBULE
60
MENS
73
WOMENS
74
KITCHEN
79
OFFICE
78
DRY
STORAGE
77
DRY
STORAGE
79A
COOLER
C04
COOLER
C04
ELECTRICAL
97B
COOLER
C03
BAR
STORAGE
100
(BELOW STAGE)
63
OFFICE
62
OFFICE
OPEN AREA
61A
TV
1D
+84"
TV
1D
+84"
TV
1D
TV
COAX
+84"
TV
1D
+84"
TV
1D
+84"
TV
1D
+84"
TP
1D
+54"
TP
1D
+54"
WAP
WAP
WAP
WAP
C
C
C
C
C
C
C
C
C
C
C
C
C
C C
C
C
C
C
C
C
C
CC
C
C
C
C
C
C
C
C
C
C C
C
1D
2D
2D
2D
2D
2D 2D
2D
2D 2D
2D4D2D
4D2D
2D
POS
2D
2D
2D
2D
2D
2D
2D
2D 2D
1D 1D
1D
2D
2D
2D
2D
2D 2D
2D
2D
2D
ATM
2D
POS
2D
POS
2D
2D
2D
2D
2D
2D
2D
4D
VW
+120"
2D
KRONOS CLOCK
1D
AIPHONE
2D
2D
1D
2D
2D
FILE
61B
2D
GAMING
COMMISSION
71
MA
TC
H LIN
EM
AT
CH
LIN
E
MATCH LINE MATCH LINE
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS204
DATA PLAN - AREA 4
AREA-5
AREA-4
AREA-3
AREA-1
AREA-2
SCALE:
DATA PLAN - AREA 4
1/8" = 1'-0"
1
GENERAL NOTES
1. REFER TO THE ITS DIAGRAM SHEETS FOR COVER PLATE LAYOUTS AND ADDITIONAL
INFORMATION.
2. SEE CABLE MATRIX ON ITS COVER SHEET FOR CABLE TYPES AND PART NUMBERS.
3. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
PROVIDE AN INSTALL DYMO #18055 SHRINK TUBE LABELS, 2” FROM MODULAR PLUG ON
BOTH ENDS.
4. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
5. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
6. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT. LOOP SHALL BE OF PROPER SIZE FOR THE AMOUNT OF CABLE
WITHIN. NO BUNDLE SHALL HAVE MORE THAN 24 CABLES.
7. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
8. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT IN BACKET TRAY LOCATIONS. NO SPACING BETWEEN LOOPS SHALL
EXCEED 4'. NO CABLE SHALL DROOP MORE THAN 6” OR TOUCH OTHER SYSTEM
CABLES, PIPES, DUCTS, OR CEILING SUPPORTS. THERE SHALL BE A MINIMUM
SEPARATION OF 6” BETWEEN LIGHT FIXTURES AND ELECTRICAL SOURCES.
9. NO MORE THAN 6” SERVICE LOOP MAY BE STORED IN OUTLET BOX LOCATION. A 10'
SERVICE LOOP SHALL BE ROLLED, COILED AND STORED IN THE CEILING CAVITY ABOVE
EACH DROP LOCATION. UTILIZE PROPER CABLE SUPPORT WITH VELCRO WRAP TO
HOLD IN PLACE.
10. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
11. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION OF ALL OUTLETS MOUNTED
ADJACENT TO ELECTRICAL OUTLETS IN WALLS OR CASEWORK PRIOR TO ROUGH-IN.
12. PROVIDE A SIEMON 5 SQUARE, EXTRA DEEP, JUNCTION BOX WITH (1) 1” KNOCKOUT
AND (1) 1/4" KNOCKOUT WITH MUD RING TO REDUCE TO A SINGLE GANG FACEPLATE.
INSTALL EITHER A 1” OR 1-1/4” CONDUIT AS REQUIRED TO CEILING SPACE WITH
SMOOTH THROAT CONNECTOR AND NYLON BUSHING FOR ALL DATA/VOICE CAT 6
OUTLETS. REFER TO THE ITS DIAGRAM SHEETS FOR FACEPLATE CONFIGURATIONS
AND ADDITIONAL INFORMATION.
13. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
14. NO CABLES SHALL BE INSTALLED PRIOR TO ANY CEILING PAINTING. DATA CABLES ARE
NOT TO BE PAINTED. ANY PAINT, OVER SPRAY OR BRUSH MARKS ARE TO BE REMOVED
PRIOR TO TESTING AND CERTIFICATION.
15. ALL HORIZONTAL CABLE SYSTEMS SHALL COME WITH AN EXTENDED MANUFACTURERS
WARRANTY. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL
HORIZONTAL COPPER CABLES USING PERMANENT LINK METHOD. TEST TO BE
PERFORMED WITH A MANUFACTURE APPROVED TESTER TO THEIR SPECIFICATIONS
AND STANDARDS. NOTE: FLUKE *DTX-1800 IS THE PREFERRED TESTER. PROVIDE
OWNERS REPRESENTATIVE COPIES OF ALL TEST RESULTS SUBMITTED TO
MANUFACTURER IN RAW TESTER FORMAT.
16. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
17. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ATIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
18. FIBER CABLING SHALL BE INSTALLED IN ACCORDANCE WITH 2008 NEC ARTICLE 770.
REFER TO SHEET ITS201 FOR KEYED NOTES.
4
11
4
11
5
4
4
1
1010
5
11
7
6
18
13
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 11: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/11.jpg)
OFFICE
80
WAITING
86
DINING
84
Bar
85
PRIVATE
DINING
83
GRAB AND
GO
15
KITCHEN
75
VIP EVENT
76
OFFICE
78
DRY
STORAGE
77
TOILET
87
TOILET
88
CONNECTION
VESTIBULE
CU
LT
UR
E
87
A
CU
LT
UR
E
87
B
DINING
84A
COOLER
C05
COOLER
C05
TV
1D
+84"
TV
1D
+84"
TV
1D
TV
1D
+84"
TV
1D
+84"
TV
1D
+84"
TV
1D
+84"
TV
1D
+84"
TP
1D
+54"
TV
1D
+84"
TV
1D/A1V
+84"
TP
1D
+54"
TP
1D
+54"
TP
1D
+54"
TV
1D
+84"
102
WAP
WAP
WAP
WAP
C C
C
C
C
C
C C C
C
C
C
C
C
C
C C
C
C
C
C
C
C
C C
4D2D
2D
POS
2D
POS
4D
2D
2D
2D
2D
2D
ATM
2D
POS
2D
2D
F F
4D
VW
+120"
2D1D
2D
POS
1D
4D
4D
3D/1AV
TV
1D
+84"
MA
TC
H LIN
EM
AT
CH
LIN
E
MATCH LINE MATCH LINE
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS205
DATA PLAN - AREA 5
AREA-5
AREA-4
AREA-3
AREA-1
AREA-2
SCALE:
DATA PLAN - AREA 5
1/8" = 1'-0"
1
GENERAL NOTES
1. REFER TO THE ITS DIAGRAM SHEETS FOR COVER PLATE LAYOUTS AND ADDITIONAL
INFORMATION.
2. SEE CABLE MATRIX ON ITS COVER SHEET FOR CABLE TYPES AND PART NUMBERS.
3. LABEL ALL DATA CABLES AT BOTH ENDS INDICATING PATCH PORT NUMBER AND
OUTLET NUMBER. SEE THE ITS DIAGRAM SHEETS FOR ADDITIONAL INFORMATION.
PROVIDE AN INSTALL DYMO #18055 SHRINK TUBE LABELS, 2” FROM MODULAR PLUG ON
BOTH ENDS.
4. ALL CABLES SHALL ROUTE BACK TO THE APPROPRIATE ER/TR/TC ROOM. THE
CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY CONDUIT, CONDUIT
FITTINGS, JUNCTION BOXES, J-HOOKS, AND WIRE BASKET TO CREATE A COMPLETE
PATHWAY.
5. DATA, VOICE, AND WIRELESS ACCESS POINTS TO BE TERMINATED ON SEPARATE
PATCH PANELS IN ER/TR/TC ROOMS.
6. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT. LOOP SHALL BE OF PROPER SIZE FOR THE AMOUNT OF CABLE
WITHIN. NO BUNDLE SHALL HAVE MORE THAN 24 CABLES.
7. PROVIDE ALL CONDUIT SLEEVES AND CONDUIT STUB-UPS WITH NYLON BUSHINGS
PRIOR TO PULLING CABLE.
8. THE CONTRACTOR SHALL UTILIZE ARLINGTON LOOPS (SADDLES) OR EQUAL FOR
CABLE SUPPORT IN BACKET TRAY LOCATIONS. NO SPACING BETWEEN LOOPS SHALL
EXCEED 4'. NO CABLE SHALL DROOP MORE THAN 6” OR TOUCH OTHER SYSTEM
CABLES, PIPES, DUCTS, OR CEILING SUPPORTS. THERE SHALL BE A MINIMUM
SEPARATION OF 6” BETWEEN LIGHT FIXTURES AND ELECTRICAL SOURCES.
9. NO MORE THAN 6” SERVICE LOOP MAY BE STORED IN OUTLET BOX LOCATION. A 10'
SERVICE LOOP SHALL BE ROLLED, COILED AND STORED IN THE CEILING CAVITY ABOVE
EACH DROP LOCATION. UTILIZE PROPER CABLE SUPPORT WITH VELCRO WRAP TO
HOLD IN PLACE.
10. ALL PENETRATIONS THROUGH FIRE RATED BUILDING STRUCTURES (WALLS AND
FLOORS) SHALL BE SEALED WITH AN APPROPRIATE UL LISTED FIRE STOP SYSTEM.
ANY PENETRATING ITEMS SUCH AS CABLES, CONDUIT, CABLE TRAY, AND RACEWAYS
SHALL BE PROPERLY FIRE STOPPED. FIRE STOP SYSTEM SHALL BE UL LISTED TO
ASTM E814 AND SHALL BE APPROVED BY THE PROFESSIONAL ENGINEER (P.E.) OF
RECORD.
11. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION OF ALL OUTLETS MOUNTED
ADJACENT TO ELECTRICAL OUTLETS IN WALLS OR CASEWORK PRIOR TO ROUGH-IN.
12. PROVIDE A SIEMON 5 SQUARE, EXTRA DEEP, JUNCTION BOX WITH (1) 1” KNOCKOUT
AND (1) 1/4" KNOCKOUT WITH MUD RING TO REDUCE TO A SINGLE GANG FACEPLATE.
INSTALL EITHER A 1” OR 1-1/4” CONDUIT AS REQUIRED TO CEILING SPACE WITH
SMOOTH THROAT CONNECTOR AND NYLON BUSHING FOR ALL DATA/VOICE CAT 6
OUTLETS. REFER TO THE ITS DIAGRAM SHEETS FOR FACEPLATE CONFIGURATIONS
AND ADDITIONAL INFORMATION.
13. THERE SHALL BE NO CABLES BUNDLED IN GROUPS GREATER THAN 24 NO CABLE TIES
SHALL BE USED ON HORIZONTAL CABLE. VELCRO IS THE ONLY ACCEPTED CABLE
BUNDLING WRAP/TIE.
14. NO CABLES SHALL BE INSTALLED PRIOR TO ANY CEILING PAINTING. DATA CABLES ARE
NOT TO BE PAINTED. ANY PAINT, OVER SPRAY OR BRUSH MARKS ARE TO BE REMOVED
PRIOR TO TESTING AND CERTIFICATION.
15. ALL HORIZONTAL CABLE SYSTEMS SHALL COME WITH AN EXTENDED MANUFACTURERS
WARRANTY. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL
HORIZONTAL COPPER CABLES USING PERMANENT LINK METHOD. TEST TO BE
PERFORMED WITH A MANUFACTURE APPROVED TESTER TO THEIR SPECIFICATIONS
AND STANDARDS. NOTE: FLUKE *DTX-1800 IS THE PREFERRED TESTER. PROVIDE
OWNERS REPRESENTATIVE COPIES OF ALL TEST RESULTS SUBMITTED TO
MANUFACTURER IN RAW TESTER FORMAT.
16. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
17. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ATIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
18. FIBER CABLING SHALL BE INSTALLED IN ACCORDANCE WITH 2008 NEC ARTICLE 770.
REFER TO SHEET ITS201 FOR KEYED NOTES.
5
4
11
4
11
13
4
7
5
13
5
17
12
7
13
11
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 12: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/12.jpg)
CISCO CISCO
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS300
ENLARGE ER 52
ELEVATIONS
145714
TYP.
11
TYP.
8
TYP.
5
TYP.
11
TYP.
3
1234 ABC
5D
3333333
2
41
41
41
41
41
27
27
35
40
23
39
38
38
38
38
38
38
37
30
32
30
33
44
44
35
35
35
35
36
34
36
27
27
2
18
29 29
18
18
18
18
47474747
28
28
16
47
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
21
18
22
22
22
22
22
20
22
22
22
22
22
22
22
22
22
22
20
OWNER
PROVIDED
CISCO
EQUIPMENT
OWNER
PROVIDED
CISCO
EQUIPMENT
17
25
CD B A
23
CABLE RUNS BETWEEN ROW 1 & ROW 2
ROW 1 CABLEROW 2
A
B
C
D
1
2
3
4
A
B
C
D
1
2
3
4
12 STRAND MM / 12 STRAND SM
24 MM
24 MM
12 STRAND MM / 12 STRAND SM
24 CAT 6A
24 CAT 6A
48 CAT 6A
48 CAT 6A
RACK #9 RACK #8 RACK #7 RACK #6 RACK #5 RACK #4 RACK #3 RACK #2 RACK #1
RACK #10RACK #11RACK #12RACK #14 RACK #13 FUTURE FUTURE
SCALE:
ENLARGED ER 52 ELEVATIONS - ROW 1
1/2"=1"-0"
A
SCALE:
ENLARGED ER 52 ELEVATIONS - ROW 2
1/2"=1"-0"
B
SCALE:
ENLARGED ER 52 ELEVATIONS - REAR RACK VIEW (ALL RACKS)
1/2"=1"-0"
C
SCALE:
ROW 1 AND ROW 2 CONNECTON KEY
NTS
D
221111
1
KEYED NOTES
INSTALL CONTRACTOR PROVIDED 2 POST RACK, #NFR84-WMPVHC45E.
INSTALL CONTRACTOR PROVIDED 4 POST RACK, MID ATLANTIC *BGR-4138.
INSTALL CONTRACTOR PROVIDED DATA CABINET, APC #AR3300.
INSTALL CONTRACTOR PROVIDED VERTICAL WIRE MANAGER, CPI #30162-703.
PROVIDE AND INSTALL 12" LADDER TRAY BLACK, CPI #10250-712.
PROVIDE AND INSTALL 18" LADDER TRAY BLACK, CPI #10250-718.
PROVIDE AND INSTALL JUNCTION SPLICE KIT BLACK, CPI #11302-701.
PROVIDE AND INSTALL BUTT SPLICE KIT BLACK, CPI #11301-701.
PROVIDE AND INSTALL 12" WALL ANGLE BLACK, CPI #11421-712.
PROVIDE AND INSTALL 18" WALL ANGLE BLACK, CPI #11421-718.
PROVIDE AND INSTALL 12" RUNWAY DROP BLACK, CPI #12100-712.
PROVIDE AND INSTALL 18" RUNWAY DROP OUT BLACK, CPI #12100-718.
PROVIDE AND INSTALL 8" SIDE DROP BLACK, CPI #12101-712.
PROVIDE AND INSTALL TOP PLATE 12" RUNWAY BLACK, CPI #10595-712.
PROVIDE AND INSTALL TOP PLATE 18" RUNWAY BLACK, CPI #10595-718.
PROVIDE AND INSTALL TELCOM GROUNDING BAR KIT, B-LINE #SBTGBK.
PROVIDE AND INSTALL 4 RMU FIBER HOUSING, PANDUIT #FRME4.
PROVIDE AND INSTALL 2 RMU HORIZONAL WIRE MANAGER, PANDUIT #WMPFIE.
PROVIDE AND INSTALL RM 110 BLACK, LEVITON #49013-P24.
PROVIDE AND INSTALL RACK MOUNT SHELF, B-LINE #SB747S1915SFB.
PROVIDE AND INSTALL 24 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP24BLY.
PROVIDE AND INSTALL 48 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP48BLY.
PROVIDE AND INSTALL RACK DRAWER, MIDDLE ATLANTIC #D3.
PROVIDE AND INSTALL HILTI SLEEVE.
PROVIDE AND INSTALL SIEMON FIBER STORAGE BOX #FSC3.
PROVIDE AND INSTALL 4" CONDUIT TO BUILDING ENTRANCE.
PROVIDE AND INSTALL APC SMART 3000VA LCD RM2U.
PROVIDE AND INSTALL RACK PDU, APC #AP7901.
PROVIDE AND INSTALL 2RMU FIBER BOX, PANDUIT #FRME2.
PROVIDE AND INSTALL 48 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL 24 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-RLY8.
PROVIDE AND INSTALL CONTROLLER, AMX #NX-4200.
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-IRS4.
PROVIDE AND INSTALL SVSI #N9206.
PROVIDE AND INSTALL DIGITAL VIDEO MATRIX SWITCH, #DTV-HR24.
PROVIDE AND INSTALL QUAD CHANNEL DIGITAL WIRELESS RECEIVER, SHURE#ULXD4Q.
PROVIDE AND INSTALL AMPLIFIER, CROWN #DCI-4-1250N.
PROVIDE AND INSTALL SIGNAL PROCESSOR, SOUNDWEB LONDON #BLU-806.
OWNER PROVIDED LANNER CONTROL PLAY.
OWNER PROVIDED LANNER PLAYER.
PROVIDE AND INSTALL CONTROLLER FOR DAKTRONICS PYLON SIGN.
PROVIDE AND INSTALL PRECISION RACK, DELL #7910.
PROVIDE AND INSTALL GREEN COUNTRY LED VIDEO WALL CONTROLLER.
PROVIDE AND INSTALL COMPLETE GE SLIMLINE POWER SYSTEM WITH RECTIFIER FORPOE POWER DISTRIBUTION.
PROVIDE AND INSTALL FIBER MODULE PANELS IN SURVEILLANCE FIBER BOX 'A' FOREXTERIOR POE FIBER CAMERAS.
PROVIDE AND INSTALL 24 PORT FLAT PATCH PANEL, PANDUIT #CPPL24WBLY.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP7830. INSTALL REAR CABINET BACKRAILS.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP8841. INSTALL REAR CABINET BACKRAILS.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
GENERAL NOTES
1. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNERSHIP AT CONCLUSION
OF JOB.
2. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
3. TEST AND SUBMIT REQUIRED WARRANTY INFORMATION FOR ALL PANDUIT FIBER
OPTIC CABLES. PROVIDE OWNERSHIP I.T. COPIES OF ALL TEST RESULTS SUBMITTED
TO PANDUIT IN THE RAW TESTER FORMAT.
4. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ACTIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
5. PROVIDE FIRE STOPPING AS REQUIRED BY CODE, FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM ROOM. PROVIDE
DRAWINGS AND PERMITS AS REQUIRED.
6. ALL CONDUITS ENTERING OR LEAVING THE TELECOM ROOM SHALL BE LABELED ON
BOTH ENDS, SHALL HAVE NYLON BUSHING BRACKET AND PULL STRING.
7. ALL RACKS AND CABINETS SHALL HAVE A LABEL ATTACHED TO THE TOP OF EACH
LOCATION. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION.
8. STRAIN RELIEF: UTILIZE VELCRO TYPE RE-ENTERABLE CABLE TIES FOR ALL MULTI PAIR
COPPER CABLES.
9. EVERY RACK AND CABINET INSTALLED SHALL HAVE A HORIZONTAL GROUNDING BUS
BAR KIT, B-LINE-#SBHBl19K, INSTALLED ON THE BACK OF A RACK OF CABINET IN THE
TOP RMU LOCATION. THE HORIZONTAL BUS BAR SHALL BE CONNECTED DIRECTLY TO
THE ROOMS GROUNDING BUS BAR.
10. ALL EMPTY OUTLETS ON EITHER THE 24 OR 48 PORT UNLOADED PATCH PANEL SHALL
HAVE BLACK BLANKS INSTALLED INTO EACH OUTLET OPENING.
11. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TELECOM
LOCATIONS.
13. COORDINATE EXACT CABINET / RACK POSITIONING WITH OWNER'S REPRESENTATIVE
TO ENSURE FLOOR TILE ALIGNMENT.
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
57 14
TYP.
11
TYP.
8
TYP.
5
TYP.
5
19
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 13: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/13.jpg)
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS301
ENLARGE ER 52
DIAGRAMS
2424
7
TYP.
9
TYP.
9
TYP.
7
TYP.
11
TYP.
5
TYP.
5
TYP.
5
TYP.
11
TYP.
11
TYP.
14
TYP.
14
TYP.
11
TYP.
14
TYP.
8
TYP.
8
TYP.
8
TYP.
13 13
9
TYP.
2626
DeMARC
11111
3 3 3 3 3 3 322
SURVEILLANCE GAMING AUDIO / VISUAL
FUTURE FUTURE RACK #10 RACK #11 RACK #12 RACK #13 RACK #14
RACK #9 RACK #8 RACK #7 RACK #6 RACK #5 RACK #4 RACK #3 RACK #2 RACK #1
16
3'-0"
3'-0"
9'-2"
11'-2"
SCALE:
ENLARGED ER 52 DIAGRAMS - LAYOUT
1/2"=1"-0"
A
SCALE:
ENLARGED ER 52 DIAGRAMS - LADDER TRAY
1/2"=1"-0"
B
FRONT
AC
CE
SS
C
ON
TR
OL
ACCESS CONTROL
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 14: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/14.jpg)
CISCO
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS302
ENLARGE TR 05
DIAGRAMS
KEYED NOTES
INSTALL CONTRACTOR PROVIDED 2 POST RACK, #NFR84-WMPVHC45E.
INSTALL CONTRACTOR PROVIDED 4 POST RACK, MID ATLANTIC *BGR-4138.
INSTALL CONTRACTOR PROVIDED DATA CABINET, APC #AR3300.
INSTALL CONTRACTOR PROVIDED VERTICAL WIRE MANAGER, CPI #30162-703.
PROVIDE AND INSTALL 12" LADDER TRAY BLACK, CPI #10250-712.
PROVIDE AND INSTALL 18" LADDER TRAY BLACK, CPI #10250-718.
PROVIDE AND INSTALL JUNCTION SPLICE KIT BLACK, CPI #11302-701.
PROVIDE AND INSTALL BUTT SPLICE KIT BLACK, CPI #11301-701.
PROVIDE AND INSTALL 12" WALL ANGLE BLACK, CPI #11421-712.
PROVIDE AND INSTALL 18" WALL ANGLE BLACK, CPI #11421-718.
PROVIDE AND INSTALL 12" RUNWAY DROP BLACK, CPI #12100-712.
PROVIDE AND INSTALL 18" RUNWAY DROP OUT BLACK, CPI #12100-718.
PROVIDE AND INSTALL 8" SIDE DROP BLACK, CPI #12101-712.
PROVIDE AND INSTALL TOP PLATE 12" RUNWAY BLACK, CPI #10595-712.
PROVIDE AND INSTALL TOP PLATE 18" RUNWAY BLACK, CPI #10595-718.
PROVIDE AND INSTALL TELCOM GROUNDING BAR KIT, B-LINE #SBTGBK.
PROVIDE AND INSTALL 4 RMU FIBER HOUSING, PANDUIT #FRME4.
PROVIDE AND INSTALL 2 RMU HORIZONAL WIRE MANAGER, PANDUIT #WMPFIE.
PROVIDE AND INSTALL RM 110 BLACK, LEVITON #49013-P24.
PROVIDE AND INSTALL RACK MOUNT SHELF, B-LINE #SB747S1915SFB.
PROVIDE AND INSTALL 24 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP24BLY.
PROVIDE AND INSTALL 48 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP48BLY.
PROVIDE AND INSTALL RACK DRAWER, MIDDLE ATLANTIC #D3.
PROVIDE AND INSTALL HILTI SLEEVE.
PROVIDE AND INSTALL SIEMON FIBER STORAGE BOX #FSC3.
PROVIDE AND INSTALL 4" CONDUIT TO BUILDING ENTRANCE.
PROVIDE AND INSTALL APC SMART 3000VA LCD RM2U.
PROVIDE AND INSTALL RACK PDU, APC #AP7901.
PROVIDE AND INSTALL 2RMU FIBER BOX, PANDUIT #FRME2.
PROVIDE AND INSTALL 48 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL 24 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-RLY8.
PROVIDE AND INSTALL CONTROLLER, AMX #NX-4200.
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-IRS4.
PROVIDE AND INSTALL SVSI #N9206.
PROVIDE AND INSTALL DIGITAL VIDEO MATRIX SWITCH, #DTV-HR24.
PROVIDE AND INSTALL QUAD CHANNEL DIGITAL WIRELESS RECEIVER, SHURE#ULXD4Q.
PROVIDE AND INSTALL AMPLIFIER, CROWN #DCI-4-1250N.
PROVIDE AND INSTALL SIGNAL PROCESSOR, SOUNDWEB LONDON #BLU-806.
OWNER PROVIDED LANNER CONTROL PLAY.
OWNER PROVIDED LANNER PLAYER.
PROVIDE AND INSTALL CONTROLLER FOR DAKTRONICS PYLON SIGN.
PROVIDE AND INSTALL PRECISION RACK, DELL #7910.
PROVIDE AND INSTALL GREEN COUNTRY LED VIDEO WALL CONTROLLER.
PROVIDE AND INSTALL COMPLETE GE SLIMLINE POWER SYSTEM WITH RECTIFIER FORPOE POWER DISTRIBUTION.
PROVIDE AND INSTALL FIBER MODULE PANELS IN SURVEILLANCE FIBER BOX 'A' FOREXTERIOR POE FIBER CAMERAS.
PROVIDE AND INSTALL 24 PORT FLAT PATCH PANEL, PANDUIT #CPPL24WBLY.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP7830. INSTALL REAR CABINET BACKRAILS.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP8841. INSTALL REAR CABINET BACKRAILS.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
GENERAL NOTES
1. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNERSHIP AT CONCLUSION
OF JOB.
2. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
3. TEST AND SUBMIT REQUIRED WARRANTY INFORMATION FOR ALL PANDUIT FIBER
OPTIC CABLES. PROVIDE OWNERSHIP I.T. COPIES OF ALL TEST RESULTS SUBMITTED
TO PANDUIT IN THE RAW TESTER FORMAT.
4. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ACTIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
5. PROVIDE FIRE STOPPING AS REQUIRED BY CODE, FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM ROOM. PROVIDE
DRAWINGS AND PERMITS AS REQUIRED.
6. ALL CONDUITS ENTERING OR LEAVING THE TELECOM ROOM SHALL BE LABELED ON
BOTH ENDS, SHALL HAVE NYLON BUSHING BRACKET AND PULL STRING.
7. ALL RACKS AND CABINETS SHALL HAVE A LABEL ATTACHED TO THE TOP OF EACH
LOCATION. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION.
8. STRAIN RELIEF: UTILIZE VELCRO TYPE RE-ENTERABLE CABLE TIES FOR ALL MULTI PAIR
COPPER CABLES.
9. EVERY RACK AND CABINET INSTALLED SHALL HAVE A HORIZONTAL GROUNDING BUS
BAR KIT, B-LINE-#SBHBl19K, INSTALLED ON THE BACK OF A RACK OF CABINET IN THE
TOP RMU LOCATION. THE HORIZONTAL BUS BAR SHALL BE CONNECTED DIRECTLY TO
THE ROOMS GROUNDING BUS BAR.
10. ALL EMPTY OUTLETS ON EITHER THE 24 OR 48 PORT UNLOADED PATCH PANEL SHALL
HAVE BLACK BLANKS INSTALLED INTO EACH OUTLET OPENING.
11. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TELECOM
LOCATIONS.
13. COORDINATE EXACT CABINET / RACK POSITIONING WITH OWNER'S REPRESENTATIVE
TO ENSURE FLOOR TILE ALIGNMENT.
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
AC
CE
SS
C
ON
TR
OL
FRONT
RACK #2
RACK #1
3'-9"
3'-11"
RACK #3
RACK #4
1
14
TYP.
5 11
TYP.
3
7
24
7
TYP.
14
TYP.
5
TYP.
11
TYP.
9
TYP.
16
1
2
2
21
2
1
8 5
8
TYP.
SCALE:
ENLARGED TR 05 DIAGRAMS - LADDER TRAY
1/2"=1"-0"
B
SCALE:
ENLARGED TR 05 DIAGRAMS - LAYOUT
1/2"=1"-0"
A
SCALE:
ENLARGED TR 05 RACK ELEVATIONS
1/2"=1"-0"
C
22
18
22
18
22
18
22
18
29
22
18
25
17
19
19
19
21
18
27
27
23
35
44
44
23
41
43
42
41
42
31
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 15: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/15.jpg)
1
14
TYP.
5
TYP.
11
TYP.
3
7
29 22
18
22
18
22
18
22
18
1 1
16
7
TYP.
9
TYP.
8
TYP.
5
TYP.
9
TYP.
SCALE:
ENLARGED TR 27 DIAGRAMS - LADDER TRAY
1/2"=1"-0"
B
SCALE:
ENLARGED TR 27 DIAGRAMS - LAYOUT
1/2"=1"-0"
A
SCALE:
ENLARGED TR 27 RACK ELEVATIONS
1/2"=1"-0"
C
24
KEYED NOTES
INSTALL CONTRACTOR PROVIDED 2 POST RACK, #NFR84-WMPVHC45E.
INSTALL CONTRACTOR PROVIDED 4 POST RACK, MID ATLANTIC *BGR-4138.
INSTALL CONTRACTOR PROVIDED DATA CABINET, APC #AR3300.
INSTALL CONTRACTOR PROVIDED VERTICAL WIRE MANAGER, CPI #30162-703.
PROVIDE AND INSTALL 12" LADDER TRAY BLACK, CPI #10250-712.
PROVIDE AND INSTALL 18" LADDER TRAY BLACK, CPI #10250-718.
PROVIDE AND INSTALL JUNCTION SPLICE KIT BLACK, CPI #11302-701.
PROVIDE AND INSTALL BUTT SPLICE KIT BLACK, CPI #11301-701.
PROVIDE AND INSTALL 12" WALL ANGLE BLACK, CPI #11421-712.
PROVIDE AND INSTALL 18" WALL ANGLE BLACK, CPI #11421-718.
PROVIDE AND INSTALL 12" RUNWAY DROP BLACK, CPI #12100-712.
PROVIDE AND INSTALL 18" RUNWAY DROP OUT BLACK, CPI #12100-718.
PROVIDE AND INSTALL 8" SIDE DROP BLACK, CPI #12101-712.
PROVIDE AND INSTALL TOP PLATE 12" RUNWAY BLACK, CPI #10595-712.
PROVIDE AND INSTALL TOP PLATE 18" RUNWAY BLACK, CPI #10595-718.
PROVIDE AND INSTALL TELCOM GROUNDING BAR KIT, B-LINE #SBTGBK.
PROVIDE AND INSTALL 4 RMU FIBER HOUSING, PANDUIT #FRME4.
PROVIDE AND INSTALL 2 RMU HORIZONAL WIRE MANAGER, PANDUIT #WMPFIE.
PROVIDE AND INSTALL RM 110 BLACK, LEVITON #49013-P24.
PROVIDE AND INSTALL RACK MOUNT SHELF, B-LINE #SB747S1915SFB.
PROVIDE AND INSTALL 24 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP24BLY.
PROVIDE AND INSTALL 48 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP48BLY.
PROVIDE AND INSTALL RACK DRAWER, MIDDLE ATLANTIC #D3.
PROVIDE AND INSTALL HILTI SLEEVE.
PROVIDE AND INSTALL SIEMON FIBER STORAGE BOX #FSC3.
PROVIDE AND INSTALL 4" CONDUIT TO BUILDING ENTRANCE.
PROVIDE AND INSTALL APC SMART 3000VA LCD RM2U.
PROVIDE AND INSTALL RACK PDU, APC #AP7901.
PROVIDE AND INSTALL 2RMU FIBER BOX, PANDUIT #FRME2.
PROVIDE AND INSTALL 48 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL 24 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-RLY8.
PROVIDE AND INSTALL CONTROLLER, AMX #NX-4200.
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-IRS4.
PROVIDE AND INSTALL SVSI #N9206.
PROVIDE AND INSTALL DIGITAL VIDEO MATRIX SWITCH, #DTV-HR24.
PROVIDE AND INSTALL QUAD CHANNEL DIGITAL WIRELESS RECEIVER, SHURE#ULXD4Q.
PROVIDE AND INSTALL AMPLIFIER, CROWN #DCI-4-1250N.
PROVIDE AND INSTALL SIGNAL PROCESSOR, SOUNDWEB LONDON #BLU-806.
OWNER PROVIDED LANNER CONTROL PLAY.
OWNER PROVIDED LANNER PLAYER.
PROVIDE AND INSTALL CONTROLLER FOR DAKTRONICS PYLON SIGN.
PROVIDE AND INSTALL PRECISION RACK, DELL #7910.
PROVIDE AND INSTALL GREEN COUNTRY LED VIDEO WALL CONTROLLER.
PROVIDE AND INSTALL COMPLETE GE SLIMLINE POWER SYSTEM WITH RECTIFIER FORPOE POWER DISTRIBUTION.
PROVIDE AND INSTALL FIBER MODULE PANELS IN SURVEILLANCE FIBER BOX 'A' FOREXTERIOR POE FIBER CAMERAS.
PROVIDE AND INSTALL 24 PORT FLAT PATCH PANEL, PANDUIT #CPPL24WBLY.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP7830. INSTALL REAR CABINET BACKRAILS.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP8841. INSTALL REAR CABINET BACKRAILS.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
GENERAL NOTES
1. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNERSHIP AT CONCLUSION
OF JOB.
2. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
3. TEST AND SUBMIT REQUIRED WARRANTY INFORMATION FOR ALL PANDUIT FIBER
OPTIC CABLES. PROVIDE OWNERSHIP I.T. COPIES OF ALL TEST RESULTS SUBMITTED
TO PANDUIT IN THE RAW TESTER FORMAT.
4. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ACTIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
5. PROVIDE FIRE STOPPING AS REQUIRED BY CODE, FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM ROOM. PROVIDE
DRAWINGS AND PERMITS AS REQUIRED.
6. ALL CONDUITS ENTERING OR LEAVING THE TELECOM ROOM SHALL BE LABELED ON
BOTH ENDS, SHALL HAVE NYLON BUSHING BRACKET AND PULL STRING.
7. ALL RACKS AND CABINETS SHALL HAVE A LABEL ATTACHED TO THE TOP OF EACH
LOCATION. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION.
8. STRAIN RELIEF: UTILIZE VELCRO TYPE RE-ENTERABLE CABLE TIES FOR ALL MULTI PAIR
COPPER CABLES.
9. EVERY RACK AND CABINET INSTALLED SHALL HAVE A HORIZONTAL GROUNDING BUS
BAR KIT, B-LINE-#SBHBl19K, INSTALLED ON THE BACK OF A RACK OF CABINET IN THE
TOP RMU LOCATION. THE HORIZONTAL BUS BAR SHALL BE CONNECTED DIRECTLY TO
THE ROOMS GROUNDING BUS BAR.
10. ALL EMPTY OUTLETS ON EITHER THE 24 OR 48 PORT UNLOADED PATCH PANEL SHALL
HAVE BLACK BLANKS INSTALLED INTO EACH OUTLET OPENING.
11. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TELECOM
LOCATIONS.
13. COORDINATE EXACT CABINET / RACK POSITIONING WITH OWNER'S REPRESENTATIVE
TO ENSURE FLOOR TILE ALIGNMENT.
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS303
ENLARGE TR 27
DIAGRAMS
ACCESS CONTROL
RACK #2 RACK #1
FRONT
3'-0"
5'-1"
1
14
TYP.
11
TYP.
20
NOT FOR CONSTRUCTION
FOR ROUGH-IN ONLY
![Page 16: DATE: JOB NUMBER: SHEET NUMBER · 2018-06-08 · 01 mens vest 10 womens vest 14 evs storage 12 mens 11 womens 13 beverage station supervisor office 37 trap 38 cart 39 cage manager](https://reader035.vdocuments.us/reader035/viewer/2022070806/5f050b807e708231d410fbd6/html5/thumbnails/16.jpg)
3'-0"
1'-8"
1
1RACK #2
RACK #1
FRONT
22
18
22
18
14
TYP.
5
TYP.
11
TYP.
3
7
1 1
24
7
TYP.
9
TYP.
14
TYP.
5
TYP.
11
TYP.
9
TYP.
16
SCALE:
ENLARGED TR 70 DIAGRAMS - LADDER TRAY
1/2"=1"-0"
B
SCALE:
ENLARGED TR 70 DIAGRAMS - LAYOUT
1/2"=1"-0"
A
SCALE:
ENLARGED TR 70 RACK ELEVATIONS
1/2"=1"-0"
A
KEYED NOTES
INSTALL CONTRACTOR PROVIDED 2 POST RACK, #NFR84-WMPVHC45E.
INSTALL CONTRACTOR PROVIDED 4 POST RACK, MID ATLANTIC *BGR-4138.
INSTALL CONTRACTOR PROVIDED DATA CABINET, APC #AR3300.
INSTALL CONTRACTOR PROVIDED VERTICAL WIRE MANAGER, CPI #30162-703.
PROVIDE AND INSTALL 12" LADDER TRAY BLACK, CPI #10250-712.
PROVIDE AND INSTALL 18" LADDER TRAY BLACK, CPI #10250-718.
PROVIDE AND INSTALL JUNCTION SPLICE KIT BLACK, CPI #11302-701.
PROVIDE AND INSTALL BUTT SPLICE KIT BLACK, CPI #11301-701.
PROVIDE AND INSTALL 12" WALL ANGLE BLACK, CPI #11421-712.
PROVIDE AND INSTALL 18" WALL ANGLE BLACK, CPI #11421-718.
PROVIDE AND INSTALL 12" RUNWAY DROP BLACK, CPI #12100-712.
PROVIDE AND INSTALL 18" RUNWAY DROP OUT BLACK, CPI #12100-718.
PROVIDE AND INSTALL 8" SIDE DROP BLACK, CPI #12101-712.
PROVIDE AND INSTALL TOP PLATE 12" RUNWAY BLACK, CPI #10595-712.
PROVIDE AND INSTALL TOP PLATE 18" RUNWAY BLACK, CPI #10595-718.
PROVIDE AND INSTALL TELCOM GROUNDING BAR KIT, B-LINE #SBTGBK.
PROVIDE AND INSTALL 4 RMU FIBER HOUSING, PANDUIT #FRME4.
PROVIDE AND INSTALL 2 RMU HORIZONAL WIRE MANAGER, PANDUIT #WMPFIE.
PROVIDE AND INSTALL RM 110 BLACK, LEVITON #49013-P24.
PROVIDE AND INSTALL RACK MOUNT SHELF, B-LINE #SB747S1915SFB.
PROVIDE AND INSTALL 24 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP24BLY.
PROVIDE AND INSTALL 48 PORT PATCH PANEL UNLOADED, PANDUIT #JICMPP48BLY.
PROVIDE AND INSTALL RACK DRAWER, MIDDLE ATLANTIC #D3.
PROVIDE AND INSTALL HILTI SLEEVE.
PROVIDE AND INSTALL SIEMON FIBER STORAGE BOX #FSC3.
PROVIDE AND INSTALL 4" CONDUIT TO BUILDING ENTRANCE.
PROVIDE AND INSTALL APC SMART 3000VA LCD RM2U.
PROVIDE AND INSTALL RACK PDU, APC #AP7901.
PROVIDE AND INSTALL 2RMU FIBER BOX, PANDUIT #FRME2.
PROVIDE AND INSTALL 48 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL 24 PORT SWITCH, CISCO #?
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-RLY8.
PROVIDE AND INSTALL CONTROLLER, AMX #NX-4200.
PROVIDE AND INSTALL CONTROLLER, AMX #EXB-IRS4.
PROVIDE AND INSTALL SVSI #N9206.
PROVIDE AND INSTALL DIGITAL VIDEO MATRIX SWITCH, #DTV-HR24.
PROVIDE AND INSTALL QUAD CHANNEL DIGITAL WIRELESS RECEIVER, SHURE#ULXD4Q.
PROVIDE AND INSTALL AMPLIFIER, CROWN #DCI-4-1250N.
PROVIDE AND INSTALL SIGNAL PROCESSOR, SOUNDWEB LONDON #BLU-806.
OWNER PROVIDED LANNER CONTROL PLAY.
OWNER PROVIDED LANNER PLAYER.
PROVIDE AND INSTALL CONTROLLER FOR DAKTRONICS PYLON SIGN.
PROVIDE AND INSTALL PRECISION RACK, DELL #7910.
PROVIDE AND INSTALL GREEN COUNTRY LED VIDEO WALL CONTROLLER.
PROVIDE AND INSTALL COMPLETE GE SLIMLINE POWER SYSTEM WITH RECTIFIER FORPOE POWER DISTRIBUTION.
PROVIDE AND INSTALL FIBER MODULE PANELS IN SURVEILLANCE FIBER BOX 'A' FOREXTERIOR POE FIBER CAMERAS.
PROVIDE AND INSTALL 24 PORT FLAT PATCH PANEL, PANDUIT #CPPL24WBLY.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP7830. INSTALL REAR CABINET BACKRAILS.
PROVIDE AND INSTALL VERTICAL PDU, APC #AP8841. INSTALL REAR CABINET BACKRAILS.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
GENERAL NOTES
1. PROVIDE ALL AS-BUILT DRAWINGS IN (DWG) FORMAT TO OWNERSHIP AT CONCLUSION
OF JOB.
2. ALL PANDUIT PRODUCTS MUST BE INSTALLED BY A PANDUIT CERTIFIED INSTALLER.
3. TEST AND SUBMIT REQUIRED WARRANTY INFORMATION FOR ALL PANDUIT FIBER
OPTIC CABLES. PROVIDE OWNERSHIP I.T. COPIES OF ALL TEST RESULTS SUBMITTED
TO PANDUIT IN THE RAW TESTER FORMAT.
4. TEST, CERTIFY AND SUBMIT WARRANTY INFORMATION FOR ALL HORIZONTAL COPPER
CABLES USING PERMANENT LINK METHOD. TESTS ARE TO BE PERFORMED WITH A
SIEMON APPROVED TESTER TO THEIR SPECIFIC ACTIONS AND STANDARDS. NOTE,
FLUKE DTX-1800 IS THE PREFERRED TESTER. PROVIDE OWNER'S I.T. COPIES OF ALL
TEST RESULTS SUBMITTED TO PANDUIT IN THE RAW TESTER FORMAT.
5. PROVIDE FIRE STOPPING AS REQUIRED BY CODE, FOR ALL FLOOR AND WALL
PENETRATIONS AND FOR ALL CONDUITS ENTERING THE TELECOM ROOM. PROVIDE
DRAWINGS AND PERMITS AS REQUIRED.
6. ALL CONDUITS ENTERING OR LEAVING THE TELECOM ROOM SHALL BE LABELED ON
BOTH ENDS, SHALL HAVE NYLON BUSHING BRACKET AND PULL STRING.
7. ALL RACKS AND CABINETS SHALL HAVE A LABEL ATTACHED TO THE TOP OF EACH
LOCATION. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION.
8. STRAIN RELIEF: UTILIZE VELCRO TYPE RE-ENTERABLE CABLE TIES FOR ALL MULTI PAIR
COPPER CABLES.
9. EVERY RACK AND CABINET INSTALLED SHALL HAVE A HORIZONTAL GROUNDING BUS
BAR KIT, B-LINE-#SBHBl19K, INSTALLED ON THE BACK OF A RACK OF CABINET IN THE
TOP RMU LOCATION. THE HORIZONTAL BUS BAR SHALL BE CONNECTED DIRECTLY TO
THE ROOMS GROUNDING BUS BAR.
10. ALL EMPTY OUTLETS ON EITHER THE 24 OR 48 PORT UNLOADED PATCH PANEL SHALL
HAVE BLACK BLANKS INSTALLED INTO EACH OUTLET OPENING.
11. PROVIDE HILTI SLEEVE PENETRATIONS FOR ALL POINTS OF ENTRY INTO TELECOM
LOCATIONS.
13. COORDINATE EXACT CABINET / RACK POSITIONING WITH OWNER'S REPRESENTATIVE
TO ENSURE FLOOR TILE ALIGNMENT.
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
CHILDERSJAMES R.
2118
S
EGISTERED ARC
HI
TECT
TA
TEOF OKLAHOM
A
R
PROFESSIONAL SEAL:
45 South 4th Street
Fort Smith, AR 72901
479-783-2480
www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8
" =
1'-0
"
04
1/4
" =
1'-0
"
04
3/8
" =
1'-0
"
04
1/2
" =
1'-0
"
6"
2
3/4
" =
1'-0
"
06
"1
1" =
1'-0
"
06
"1
1 1
/2
" =
1'-0
"
01
3" =
1'-0
"
6"
16
8
CLIENT:
CONSULTANT LOGO:
17-06
TA
HL
EQ
UA
H C
AS
IN
O
CH
ER
OK
EE
N
AT
IO
N E
NT
ER
TA
IN
ME
NT
TA
HLE
QU
AH
, O
KLA
HO
MA
# DATE DESCRIPTION
BID PACKAGE 5
(ADDENDUM #10)
05/22/2018
ITS304
ENLARGE TR 70
DIAGRAMS
29
22
18
22
18
20
NOT FOR CONSTRUCTION