Dr Fathi Tarada

Managing Director

Mosen Ltd

MoJet Tunnel Ventilation – Testing and CFD Analysis

Page 3: Date and City - .GLOBAL

Introduction to Mosen Ltd www.mosen.global

3

Mosen Ltd is an engineering consultancy with expertise in

• tunnel ventilation

• fire safety engineering

• risk management

• tunnel safety

• Computational Fluid Dynamics

We have worked on >100 tunnels worldwide.

Page 4: Date and City - .GLOBAL

mosen mosen

Motivation

• Cost and power consumption for tunnel ventilation can be very high

• The MoJet was invented as a sustainable, energy-efficient device, using ANSYS CFX

• Measurements were undertaken to check the real performance

Page 5: Date and City - .GLOBAL

mosen mosen

Agenda

1. What is the MoJet?

2. Model scale tests

3. Full-scale tests

4. Conclusions and outlook

Page 6: Date and City - .GLOBAL

mosen mosen

MoJet• Energy-efficient jetfan

• Uses shaped nozzles

• Reduces the Coanda effect, hence increasing the in-tunnel thrust

• Reduces the in-fan pressure drop, hence reducing the power consumption

Page 7: Date and City - .GLOBAL

mosen mosen

Model Scale Testing

Page 8: Date and City - .GLOBAL

mosen mosen

Model Scale Testing

• Undertaken at the Institute of Aerodynamics, RWTH University in Aachen

• History of previous research in tunnel aerodynamics with jetfans

Page 9: Date and City - .GLOBAL

mosen mosen

1:18 Model Scale Tests

Jetfan diameter = 7 cm

Page 10: Date and City - .GLOBAL

mosen mosen

Model-Scale Tunnel

• 10 m long

• Jetfans installed at 2 m from inlet portal

• PIV air velocity measurements undertaken near outlet portal

Page 11: Date and City - .GLOBAL

mosen mosen

1:18 Model Scale Tests

Page 12: Date and City - .GLOBAL

mosen mosen

MoJet Installation

Page 13: Date and City - .GLOBAL

mosen mosen

Flow Discharge from MoJet

Page 14: Date and City - .GLOBAL

mosen mosen

Results from Model Scale Tests

Value

Reynolds Number (Real to Model Scale) x 18

Tunnel friction drag (MoJet to conventional) -20%

Jetfan thrust/power ratio (MoJet to conventional)

+10%

Page 15: Date and City - .GLOBAL

mosen mosen

Full-Scale Testing

Page 16: Date and City - .GLOBAL

mosen mosen

Montgomery Tunnel, Brussels

Jetfan installed in tunnel corner

Page 17: Date and City - .GLOBAL

mosen mosen

Full-Scale Jetfan Testing

• 500 m long tunnel

• 10 jetfans in each tunnel bore; mixture of 550 mm and 630 mm internal diameter

• 3 jetfans to be replaced for test

• Conventional jetfan and MoJet comparison (in-tunnel thrust and power consumption)

• Test scheduled in 2019

Page 18: Date and City - .GLOBAL

mosen mosen

Tunnel Geometry

Southern portal

Northern portal

Fan 20

Fan 18

Traffic and flow direction

Fan 16

Page 19: Date and City - .GLOBAL

mosen mosen

Case configuration

• The simulations were run in CFX 19.2 with the following conditions:

– Fan rotational speed of 2900rpm

– Non-buoyant model

– 1 atm Reference Pressure

– Total Energy with Viscous Work Term

– Turbulence Model SST

Page 20: Date and City - .GLOBAL

mosen mosen

CASE SET-UP

Page 21: Date and City - .GLOBAL

mosen mosen

Case Set-Up

• The conventional jetfan and MoJet (exhaust silencer only) were compared in the following CFD simulations:

– Bench thrust (jetfans in isolation).

– Three fans running in the Southernmost locations (16, 18, 20) of the Northbound tunnel (flow direction going from South to North).

Page 22: Date and City - .GLOBAL

mosen mosen

BENCH THRUST SIMULATIONS

Case configuration

Page 23: Date and City - .GLOBAL

mosen mosen

Case configuration

• Motor mesh

Page 24: Date and City - .GLOBAL

mosen mosen

Case configuration

• Blade mesh

Page 25: Date and City - .GLOBAL

mosen mosen

Case configuration

• Silencer mesh

Page 26: Date and City - .GLOBAL

mosen mosen

Case configuration

• Conventional jetfan volume mesh23 million cells

Page 27: Date and City - .GLOBAL

mosen mosen

Case configuration

• MoJet volume mesh29 million cells

Page 28: Date and City - .GLOBAL

mosen mosen

BENCH THRUST SIMULATIONS

Case results

Page 29: Date and City - .GLOBAL

mosen mosen

Case results

• Experimental results:

– Ux 30.5 m/s (21° pitch angle)

• Conventional jetfan

– Ux 27.5 m/s (mass flow average)

– VFR 8.21 m³/s

• MoJet

– Ux 30.8 m/s (mass flow average)

– VFR 8.27 m³/s

Page 30: Date and City - .GLOBAL

mosen mosen

Velocity Contours

Page 31: Date and City - .GLOBAL

mosen mosen

Velocity Contours

Page 32: Date and City - .GLOBAL

mosen mosen

Flow Deflection

• The MoJet achieved a deflection angle of 11° from the horizontal axis.

Page 33: Date and City - .GLOBAL

mosen mosen

TUNNEL SIMULATIONS

Case configuration

Page 34: Date and City - .GLOBAL

mosen mosen

Case configuration

• Tunnel volume mesh

Page 35: Date and City - .GLOBAL

mosen mosen

Case configuration

• Conventional jetfan volume mesh

50 million cells

Page 36: Date and City - .GLOBAL

mosen mosen

Case configuration

• MoJet volume mesh

51 million cells

Page 37: Date and City - .GLOBAL

mosen mosen

TUNNEL SIMULATIONS

Case results

Page 38: Date and City - .GLOBAL

mosen mosen

Case results

• Contour plot of velocity at the Northern portal outlet.

Conventional MoJet

Page 39: Date and City - .GLOBAL

mosen mosen

Case results

• The volumetric flow rate (m³/s) is shown below :

• Conventional MoJet

– Location 20 8.30 8.36

– Location 18 8.32 8.35

– Location 16 8.32 8.35

Page 40: Date and City - .GLOBAL

mosen mosen

Case results

• Applying the volumetric flow rates from the tunnel simulations to 1D CFD (using IDA RTV) produces the following installation factors :

– Conventional 0.25

– MoJet 0.53 (+112%)

Page 41: Date and City - .GLOBAL

mosen mosen

Velocity Streamline ComparisonLocation 20 streamlinesConventionalMoJet

Downstream clipping plane (X130m) active to show distribution within tunnel

Page 42: Date and City - .GLOBAL

mosen mosen

Velocity Streamline ComparisonLocation 18 streamlinesConventionalMoJet

Downstream clipping plane (X130m) active to show distribution

Page 43: Date and City - .GLOBAL

mosen mosen

Velocity Iso-surface ComparisonU 10m/s iso-surfacesConventionalMoJet

Page 44: Date and City - .GLOBAL

mosen mosen

Case results

• As expected a decrease in shear stress on the tunnel walls is noted with the MoJet.

Conventional MoJetConventional

Page 45: Date and City - .GLOBAL

mosen mosen

Flow Distribution

• A comparison of the flow leaving the first fan (location 20) shows the MoJet having better distribution within the tunnel.

• The flow from the conventional fan remains attached to the tunnel ceiling and walls, thereby reducing efficiency.

• The flow from the conventional jetfan (at location 20) also gets re-ingested by the downstream fan (location 18).

Page 46: Date and City - .GLOBAL

mosen mosen

Velocity & Thrust Comparison

• The average velocity at the Northern portal (outlet) was:

– Conventional

• Flow speed 1.59 m/s

– MoJet

• Flow speed 2.28 m/s (+44%)

• Thrust increase above conventional jetfan +106%

Page 47: Date and City - .GLOBAL

mosen mosen

Conclusions and Outlook

• ANSYS CFX has been used to develop a patented new product for tunnel ventilation –the MoJet

• Significant reduction in the number of jetfans required in a tunnel

• Model-scale tests have confirmed the potential benefits of the MoJet

• Full-scale tests planned for 2019

Page 48: Date and City - .GLOBAL

mosen mosen

www.mosen.global

Page 49: Date and City - .GLOBAL

Presentation Title (required) [28pt, bold]

Thank You and Questions

49