datalogger considerations presented by: glenn gehring technology specialist iii institute for tribal...
TRANSCRIPT
Datalogger Considerations
Presented by: Glenn Gehring
Technology Specialist III
Institute for Tribal Environmental Professionals (ITEP)
Tribal Air Monitoring Support (TAMS) Center
1
Dataloggers and Met
• An overview—not comprehensive
• Focused on the practical
• Detailed training is available from datalogger manufacturers
2
Common Types of Communication• Analog
• Instrument outputs a voltage• Datalogger senses voltage• Both must know what the voltage represents
• Range of voltage used concentration range of instrument must be coordinated between datalogger and instrument
• Digital• Direct communication – data streams
• Compatibility and connection/communication parameters
• Current• Instrument outputs current• Current is passed through a close-tolerance resistor• Datalogger senses voltage drop across resistor
3
Electricity
• Voltage is electrical potential• Provides driving force for current flow
• Current• Movement of electrons through a conductor
• Resistance• resistance to current flow
• OHM’s Law – there is a relationship
4
Voltage = Current X Resistance (E=IR)
5
Some Rules Help
Current is constant throughout circuitVoltages are different at points 1,2,3,4
Current can vary through R1,R2,R3Voltage is similar at Points 1,2,3,4Voltage is similar at points 8,7,6,5
See www.allaboutcircuits.com to learn more about basic circuits
7
• Some sensor manufactures provide jumpers on their units so you can change outputs.
• Example: some RM Young wind speed sensors can be set to either a 1- or 5-volt output by moving jumpers on the sensor
10
Voltage Temperature Depending on whether the datalogger uses volts or millivolts the multiplier will be either 20 or 0.02
What is the offset?
-50°C
Example of analog datalogger concepts: let’s look at configuring an analog temperature sensor to a datalogger. We will determine the multiplier and the offset to enter into the datalogger.
Assume the temperature sensor senses a range of temperatures from -50°C to +50°C. That means the sensor can measure a total range of 100°C. Also, let’s assume the sensor has a 5-volt maximum
output. What is the multiplier and what is the offset?
+50°C
0 Volts
5 VoltsFull range of sensor
Full range of voltage= Multiplier
=100°C
5 Volts20
=100°C
5000 Millivolts0.02
Note: If I wanted to also log °F or Kelvin I could create additional channels and use unit conversions to get multipliers. In this example, the 100°Crange would be 180 °F (-50°C = -58 °F) (+50 °C = +122 °F)(122 + 58 = 180)
2.5 Volts 0°C
Offset examplesWhere is the low end of the instrument range in relation to 0?
11
0
0
Temperature ºC
-50 ºC +50 ºC Range = 100 ºCLow end of range = -50
Offset = -50
223 K 323 K
Temperature ºF
-58 ºF +122 ºF Range = 180 ºFLow end of range = -58
Offset = -58
Temperature in Kelvin
Offset is +223
Datalogger Configuration Differences• Some dataloggers need a multiplier and an
offset for configuration• ESC asks for
• Volts High Input• Volts Low Input• High Output E.U.s• Low Output E.U.s
And then calculates multiplier and offset
12
15
Analog ExamplesCampbell
Where is the wire connected?
Volt rangePPB Range 500Volts 5000 mV
500
5000= 0.1
UNITS !!!
Multiplier
18
Note that Ch1 has a “–” and a “+”A differential connection on Ch1 would just say 1A single ended connection would say “1-”, or “1+”
Single-Ended & Differential Voltage(Campbell Scientific – SE & DIFF)
19
2.5 VoltsDatalogger
2.4 VoltsDatalogger
Ground
.1 Volt(L)
2.5 Volts(H)
Differentialmeasures between
two voltages
2.5 Volts
Single-Endedmeasures between
SE terminal and ground
Sensor Sensor
1
H L
Diff
SE 1 2
(Differential Channel 1)
(Screw-on datalogger)
(Single-ended channel 2)
Wind Speed Sensors• Wind Speed
Sine wave
Pulsed frequency
23
Time
+
+
-
Hz (Hertz) is cycles per second
Use sensor unit specs for range
Also, varying voltage, for example0 volts = 0 mph
5 volts = 112 mph
http://www.epa.gov/ttn/amtic/qalist.html
EPA’s Technology Transfer Networkhttp://www.epa.gov/ttn/
Some videos
What about wind direction averaging?
Met site
North
South
Winds 2:00pm to 2:30pm
Winds 2:30pm to 3:00pm(slower wind speed)
Consider this. The datalogger is typically set to average winds every hour. If winds blow from the north for ½ hour and then
shift to the south for the next ½ hour, what is the 1-hour average direction the
winds came from during that hour?
(0 degrees + 180 degrees) ÷ 2 = 90 degrees(scalar averaging)
But, the winds never blew from the east!
Looking at the wind speed differences we intuitively see that the net impact on the
movement of pollutants would be movement toward the south since the
wind speeds were higher from the north.Vector averaging looks at both wind
speed and direction.
As if that isn’t enough, 360 and 0 degrees represent the same thing.
And, what do we do when averaging during an hour that has both calm
winds and winds? Also, what about vertical movement?
More about Wind-Direction Averaging• Some dataloggers have math packs that configure several
channels for wind automatically. You can use both scalar and vector averaging at same time from same wind sensors
• Some dataloggers have ability for more complex programming to suite your specific needs (you must understand basic computer programming to do this, but some dataloggers allow for a high degree of customization)
• So how do we interpret winds from our sensors? That can be complex.
• In simple terms when you see a vector average you are looking at both wind speed and wind direction combined into vectors. The 1-hour averaging provides the net result (resultant) on air movement for the hour
28
Wind-Direction Averaging (cont.)
• Sometimes winds are mostly from one direction during the hour. Sometimes they vary a lot
• Sigma Theta (term used in hourly data): standard deviation of winds during hour
• “High sigma theta” means highly variable winds where “low sigma theta” indicates winds are more consistent
• Important when interpreting wind data• Sometimes it is good to know maximum gust each
hour in addition to hourly average.• I recommended you configure datalogger to log
maximum gusts
Declination calculatorhttp://www.ngdc.noaa.gov/geomagmodels/Declination.jsp
TrueNorth Magnetic
NorthMagnetic
declination is the difference
between magnetic and true north
Wind direction must be
properly aligned to north, usually
true north
South mark on sensor
Graphic from USGS
31
Sensor grounds
Power grounds & Power outs
Or can use a ground terminal for power grounds
As a side note, what is warmup all about and how does that relate to power out?
32
• Option to add heaters on some sensors (eg. wind sensor)
• Used so ice/snow won’t stop measurements • Or, in case of precipitation gauge, to melt snow/ice
for total precipitation measurements • You can NOT power heater with power from datalogger
• Power supplies limited • You can typically power sensor from datalogger, or from
separate power supply • But heater wires must use separate power supply
capable of supplying electrical demands of heater
Datalogger Power
Compatibility!!!
• Meteorological sensors have variety of output signals datalogger must interpret and log
• Wind speed sensors can output signals as varying voltage, an alternating current, direct current pulse, etc.
• Datalogger must have capability to accept this type of signal at range of frequencies your wind speed sensor outputs.
• Not all dataloggers can accept frequency signals or have limited frequency ranges they can accept.
• A tipping bucket rain gauge outputs a signal when enough rain has entered to cause it to tip
34
• Datalogger must count number of tips in a period of time. Sensors with analog outputs (voltage outputs) have ranges such as 0 - 1 volt, 0 - 5 volts, or higher
• Sometimes analog output signal depends on voltage you supply to sensor
• If datalogger can only accept 2500 millivolts (2.5 volts), 0 - 5 volt sensor would be more difficult to connect
• Put on your electrical engineer hat & it can be done, but do you own an electrical engineer hat? Why make it hard? Think it through and triple check everything for compatibility with different sources before you purchase
Compatibility (cont.)
35
InternetOr
IntranetLocal Network
Router
ESC 8832 Ethernet connection
ESC cable
Computer cable (laptop, for example)
ESC 8832 Ethernet connectionMust set IP addresses
Do I need a crossover cable to connect???- not likely when connecting through a router.
36
USB to serial adapter connects to computer. Or you may have a serial port on the
computer
If you notice both serial
connections are male
pinsA gender
changer doesn’t change the wire orientation. It is
a “straight through”
connection to adapt male and
female pinsIn general, although
individual adapters can be different, the null modem switches the receive and transmit wires on the cable. If one instrument sends
on a wire the other must be able to receive on that same wire. If they
both try to send or receive on the same
wire it won’t work.
You may need a null
modem adapter or
cable
Rx
Tx Tx
RxInst. 1 Inst. 2
Won’t work
Tx
Rx Tx
RxInst. 1 Inst. 2
Will work
Wires Wires
Null Modems
37
From ESC 8832 manual:
HyperTerminal
(XP, or XP Mode in Windows 7, built in terminal communications software)
For serial communications these settings MUST match
your datalogger
38
SiteDatalogger
Serial to Ethernet adapter
Notice null
modem
Office Radio
2 antennas
Site Radio
Router
To computer, LAN, Internet, etc.
Basic telemetry (one of many methods)
39
In truth, dataloggers could be an entire course! Oh yeah, it IS! It just hasn’t been offered in a while. This course touches on dataloggers, but I’m still learning and I imagine I will still
be learning a decade from now. That’s the fun and that’s the challenge. Each of us needs to develop our own
understanding. We each need to trudge through until we get a working knowledge, and then if we are of the curious sort, we keep trying to improve our understanding. The exercises in this course are designed to introduce concepts rather than just focusing on procedures. If you understand the system,
the concepts, you can do anything. A step-by-step procedure only teaches a procedure. We do have procedures built in,
but hopefully you can take some time to explore the equipment. How does it work? Why am I doing this
procedure? Where IS that coffee pot? Happy learning!