damage occurring in fcc hexmesh systems · 17 citgo’s 2015 investigation of hexmesh damage in a...

27
© 2010 CITGO Petroleum Corporation. Damage Occurring in FCC Hexmesh Systems Jerry Wilks Senior Corrosion & Materials Engineer Lemont Refinery

Upload: others

Post on 24-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

© 2010 CITGO Petroleum Corporation.

Damage Occurring in FCC Hexmesh Systems

Jerry Wilks

Senior Corrosion & Materials Engineer

Lemont Refinery

Page 2: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

2

Damage Occurring in FCC Hexmesh Systems

• Reactor Hexmesh Damage

o Hexmesh that separated from the vessel wall

o Brittle fracture of the welds

o Corrosion and cracking of the hexmesh steel at the attachment welds

• Regenerator Hexmesh Damage

o Examples of failures

o Sigma embrittlement of FCC Regenerator welds

o Carburization of hexmesh steel and welds

o Test sample cut from FCC cyclone crossover piping

o Damage found at the interface

Page 3: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

3

Hexmesh that Separated from the Reactor Wall

Welds that Held Hexmesh to the

Vessel Wall

Reactor Operating Temperature960-990°°°°F 510F 510F 510F 510----530530530530°°°°C C C C

Page 4: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Why the Welds Holding the Hexmesh Failed

4

E309 Weld

Something happened along the weld metal to 1Cr-½Mo interface.

Extra E309 Weld Metal?

Corrosion of Sensitized Hexmeshwith minor cracking

1Cr-½Mo½Mo½Mo½Mo

Vessel Wall Vessel Wall Vessel Wall Vessel Wall

Was Here

Bakelite

Page 5: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Weld Metal at the Vessel-to-Weld Interface

5

Carbon from the 1Cr-½Mo diffused into the stainless steel forming chromium carbides and lowering the fracture toughness of the weld metal. Refer to NACE Paper 626 from NACE Corrosion 1993 for examples of this phenomenon.

1Cr-½Mo Vessel Wall ½Mo Vessel Wall ½Mo Vessel Wall ½Mo Vessel Wall Was Here

E309 Weld Metal

Brittle Fractures Chromium Carbides

Along the Interface

Cold wall designprevents these failures by preventing carbon diffusion into the stainless.

Page 6: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Example of Regenerator Hexmesh FailuresInside of a cyclone

6

Black Sulfide Deposits

Behind the Hexmesh

Pushed the Hexmesh Out

Page 7: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Hexmesh Metal Completely Corroded Away

7

Hexmesh Metal Corroded Away

Leaving Deposits Mixture of Sulfides

and Oxides

Page 8: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Results of Corrosion Deposit Analysis

8

Metal sulfides convert to oxides when exposed to air, so while in-service the deposits contained more sulfur.

Table A1-2: Results of the Analysis of the Corrosion Product from Hexmesh Steel

Element Atomic % Weight %

Oxygen 35.6 16.6

Iron 23.0 37.3

Chromium 14.4 21.8

Sulfur 10.9 10.2

Carbon 8.3 2.9

Nickel 4.2 7.2

Manganese 1.6 1.3

Others Elements 2.62 1.54

Corrosion Product from the Hexmesh

Other Elements

Page 9: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Areas Where Welds Fractured and Hex Corroded

9

Red arrows point to fractured welds. White arrows point to corrosion damage.

Page 10: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Close-up of the Weld Fracture and Corroded Hex

10

Fractured Weld

Corroded 304H Hexmesh

Page 11: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

What’s Happening to the Stainless Steel?

11

Carburized Stainless

Fractured Weld

Page 12: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Carburization of 304H Stainless Steel

12

Failed Weld

Hexmesh304H

Carburized Stainless - Brittle

Page 13: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

13

Carburized Stainless at Higher MagnificationsCorrosion occurred around the chromium carbides.

ChromiumCarbides

Oxides &Sulfides

Page 14: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Composition of the Chromium Carbide in Hexmesh

14

The exact formula for pure chromium carbide is Cr23C6, but the composition of

metal carbides typically varies with some Fe, Mn, and Ni in place of Cr atoms.

When chromium carbides form, the surrounding stainless becomes non-stainless.

Table A1-1: Results of the Analysis of the Corroding Phase in the Cyclone Hexmesh

Elements Present in Order of Decending

Atomic % Atomic % Weight %

Chromium 47.94 61.03 Carbon 27.00 7.94 Iron 17.58 24.04 Nickel 2.02 2.90 Oxygen 2.00 0.79 Sulfur 1.39 1.09 Manganese 1.06 1.42 Silicon 0.82 0.57 Other 0.17 0.22

Analysis of Chromium Carbides in 304H

Elements Present inOrder of Descending

Atomic %

Page 15: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Sigma Formation in Weld Metal Causing Brittle Weld Fractures

15

The dark phase is sigma in E309 weld metal – it creates aligned weak interfaces.

Page 16: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Regenerator Cyclone Welds vs. Wall Test Results

16

0

5

10

15

20

25

30

35

40

25 30 35 40 45 50 55 60 65 70 75

Weld

Cyclone Wall

Results of Charpy Impact Testing of Regenerator Cyclones

Temperature (°F)

Imp

ac

t E

ne

rgy

(Fo

ot-

Po

un

ds

)

0

5

10

15

20

25

30

35

40

25 30 35 40 45 50 55 60 65 70 75

Weld

Cyclone Wall

0

5

10

15

20

25

30

35

40

25 30 35 40 45 50 55 60 65 70 75

Weld

Cyclone Wall

Results of Charpy Impact Testing of Regenerator Cyclones

Temperature (°F)

Imp

ac

t E

ne

rgy

(Fo

ot-

Po

un

ds

)

Fracture toughness this low could cause brittle fracture while in-service or during shut-downs.

10 Imp

act

En

erg

y –

Jo

ule

s

0

0-5 5 1510 20 25

Temperature (°°°°F)F)F)F)

Temperature (°°°°C)C)C)C)

20

30

40

50

Page 17: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

17

CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service

o Test sample cut from FCC Regen crossover duct

o Early in the degradation so mechanisms can be seen

o Specimens dry cut from the sample to avoid contamination

o The interface between refractory and steel was inspected and damage was found at the interface

o Analysis of corrosion deposits and phases present to identify the corrosion mechanism

Page 18: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Process Temperature During the 5 Year Run

18

1350

1300

1400

Process Pressure: 25-33 psig 172-228 kPa

Regenerator Was Running Partial Burn

1200

1150

1250

1100

2010 T

urn

aro

un

d

700

750

650

Tem

pera

ture

°° °°FTem

pera

ture

°° °°C

600

Page 19: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

2015 Sample Cut from the Lemont Regenerator

19

Page 20: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Specimens Cut from the Sample

20

Page 21: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Close-up of the Refractory-Steel Interface

21

Typical Interface - Tight Some Areas Not Tight

AA-22 Refractory

Page 22: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Damage Found at the Refractory-Steel Interface

22

Metal

Oxides

Bakelite

Corrosion Penetrating the 304H Beneath the Surface Pit.

Page 23: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

23

Sulfides inGrain Boundaries

Oxides in Grain Boundaries

with Some Sulfur

Mixture of Oxides and Sulfides with Steel Fragments

A Closer Look at the Corrosion Damage

Page 24: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

X-Ray Analysis Results for Light Grey Deposits

24

No Oxygen

Peak

Page 25: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Electron Microscope View of the Damage

25

BakeliteSteel

Oxides

Oxides and Sulfides

Sulfides

Page 26: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Chromium Oxide Prevents Stainless Corrosion

26

Etched with Oxalic Acid Original - 100X

Chromium Oxide Protective Layer

Page 27: Damage Occurring in FCC Hexmesh Systems · 17 CITGO’s 2015 Investigation of Hexmesh Damage in a Regenerator after 5 Years of Service oTest sample cut from FCC Regen crossover duct

Conclusions• Hexmesh failures in FCC Reactors at the vessel wall can be

significantly reduced or eliminated with cold wall reactor design.

• Cold wall design prevents diffusion of carbon into the weld metal and avoids brittle fracture of welds.

• Polythionic stress corrosion cracking occurs in the hexmesh steel due to sensitization at the welds holding the hexmesh to the wall.

• Hexmesh failures in FCC regenerators are caused by carburization of the 304H hexmesh and carburization of E308 or E309 weld metal.

• Corrosion in FCC regenerators occurs due to both oxidation and sulfidation. Carburization of the stainless promotes the corrosion.

• Going to full burn operation in the Regenerator should reduce the sulfidation corrosion and that could also reduce oxidation.

• Sigma formation in FCC Regenerator welds causes the weld metal to become brittle, and easily fracture in service or during turnarounds.

• The chromium oxide protective layer on the stainless is very thin and damage of that thin layer by refractory movement could occur

27