Upload: mary-garrison

Post on 21-Jan-2016

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

D. Dąbrowski, M. Peryt, K. Rosłon

Gas system for MPD Time-of-Flight detector

3-7 November 2015 NICA DaysD. Dąbrowski

Page 2: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

Tracking: TPC, IT, ECT

T0, Triggering: FFD

Centrality, Event plane: ZDC

Particle ID: TOF, ECAL, TPCFFD

MultiPurpose Detector (MPD)

3-7 November 2015 NICA DaysD. Dąbrowski

Page 3: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

Time-Of-Flight (TOF) detector

MPD TOF TDR 2015

MPD TOF TDR 2015

MPD TOF TDR 2015

3-7 November 2015 NICA DaysD. Dąbrowski

Page 4: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

4

Particle IDentification (PID):

How does it work ?

MPD TOF TDR 2015

0.5<p<1 GeV/c

3-7 November 2015 NICA DaysD. Dąbrowski

Page 5: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

5

Gas mixture requirements:

- Low threshold of avalanches

- Fast (high electrons drift velocity)

- No secondary effects, like photon feedback

- Cheap, Eco-friendly, safe, not ageing 3-7 November 2015 NICA Days

D. Dąbrowski

Page 6: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

6

Gas Mixture

90% C2H2F4 + 5% i-C4H10 + 5% SF6

3-7 November 2015 NICA DaysD. Dąbrowski

Page 7: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

7

Purity

O2 content: < 1000 ppm

H2O content: < 100 ppm

Two effects: - modification of transport parameters- electron loss by capture due to

electro-negative pollutants

3-7 November 2015 NICA DaysD. Dąbrowski

Page 8: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

8

Gas system

3-7 November 2015 NICA DaysD. Dąbrowski

Page 9: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

3-7 November 2015 NICA DaysD. Dąbrowski

Gas supply system

Page 10: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

Mixer

3-7 November 2015 NICA DaysD. Dąbrowski

Page 11: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

Purification

3-7 November 2015 NICA DaysD. Dąbrowski

Page 12: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

Control system

3-7 November 2015 NICA DaysD. Dąbrowski

Page 13: D. Dąbrowski, M. Peryt, K. Rosłon Gas system for MPD Time-of-Flight detector 3-7 November 2015NICA DaysD. Dąbrowski

3-7 November 2015 NICA DaysD. Dąbrowski

Thank you for your attention !