c:usersjeffdocumentshawthorne elementary - … · 2019. 1. 28. · ansi/tia -526 -14 -c,...

8
PRINCIPAL 407 LOUNGE 412 COUNSELOR 411 NURSE 409 MAIL / WORK 408 RECEPTION 406 ENTRANCE 404 1ST GRADE 403 K2 EXTENDED 402 MUSIC / ORCH 204 3RD GRADE 423 MUSIC / ORCH 211 SERVING 200 MULTIPURPOSE 414 I.T. 416 SPECIAL ED 122 2ND GRADE 112 BREAKOUT 219A BREAKOUT 231 2ND GRADE 110 2ND GRADE 111 ELEVATOR 417-1 KITCHEN PREP 203 KINDERGARTEN 118 KINDERGARTEN 120 KINDERGARTEN 121 1ST GRADE 116 1ST GRADE 115 1ST GRADE 108 2ND GRADE 109 3/5 EXTENDED 221 5TH GRADE 234 3RD GRADE 232 3RD GRADE 219 CORRIDOR 5 15 CORRIDOR 1 11 CORRIDOR 3 13 TITLE 1 233 JANITOR 205 HALL 12 HALL 18 CLOSET 230 STAIR 1 20 CHASE/DATA 205A STORAGE 218 BREAKOUT 426 BREAKOUT 425 OPEN OFFICE 410 ART/KILN 415 CONFERENCE ROOM 413 LIBRARY 427 CSCT 422 SENSORY 402B OT 402C PT 221.1 CORRIDOR 4 14 BOILER 214 GYM 223 3/5 COATS 221D 3/5 BREAKOUT 221A 3/5 STORAGE 221C TECHNOLOGY 114 FRC 424 LIBRARY 113 FLAGSHIP 424A PRINTING 406B BICYCLE STORAGE 228 24 23 22 21 20 19 6 6 5 4 3 13 15 16 17 18 T3-6 1 T3-4 1 T3-5 1 T3-3 1 RR J 402A PRACTICE 2 211A PRACTICE 1 211B JANITOR 437 T7-1 1 1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF: ANSI/TIA - 526 - 7 - A, Measurement of Optical Power Loss of Installed Single - Mode Fiber Cable Plant, and its published addenda. ANSI/TIA - 526 - 14 - C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda. ANSI/TIA - 568.0 - D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA - 568.1 - D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda. ANSI/TIA - 568.2 - D, Balanced Twisted - Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA - 568.3 - D, Optical Fiber Cabling and Components Standard, and its published addenda. ANSI/TIA - 569 - D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598 - D Optical Fiber Cable Color Coding ANSI/TIA - 606 - C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA - 607 - C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA - 758 - B, Customer Owned Outside - Plant Telecommunications Infrastructure Standard, and its published addenda. 2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS. 3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J - HOOKS OR BY CABLE TRAY. 4. ALL CABLING, J - HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR. 5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O. 6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O. 7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS. 8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR. PLAN NOTES: DSA, P.C. COPYRIGHT DRAWN BY: PROJECT: REVISIONS: JG 2300 REGENT ST., Suite 207 Missoula, MT 59801 ph: 406.327.0629 fax: 406.541.9881 access-consulting.net 1/22/201 9 10:53:10 AM Y:\2018\ MCPS\Hawthorn e Elementary\Dr awings\Revit\Tel ecomm\Hawthorn e Element ary - Telecommu nications - Cabli ng v18.rvt T3-1 01 22 19 TELECOMM PLAN - FIRST FLOOR - OVERALL HAWTHORNE SCHOOL 2835 S 3rd St W Missoula, MT 59804 100% CONSTRUCTION DOCUMENT SET 17-533 1/16" = 1'-0" 1 TELECOMM PLAN - FIRST FLOOR - OVERALL 1979 2008 1951 2018 2018 2018 2018 N

Upload: others

Post on 20-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

PRINCIPAL

407

LOUNGE

412

COUNSELOR

411

NURSE

409

MAIL / WORK

408

RECEPTION

406

ENTRANCE

404

1ST GRADE

403

K2

EXTENDED

402

MUSIC /

ORCH

204

3RD GRADE

423

MUSIC /

ORCH

211

SERVING

200

MULTIPURPOSE

414

I.T.

416

SPECIAL ED

122

2ND GRADE

112

BREAKOUT

219A

BREAKOUT

231

2ND GRADE

110

2ND GRADE

111

ELEVATOR

417-1

KITCHEN

PREP

203

KINDERGARTEN

118

KINDERGARTEN

120

KINDERGARTEN

121

1ST GRADE

116

1ST GRADE

115

1ST GRADE

108

2ND GRADE

109

3/5

EXTENDED

221

5TH GRADE

234

3RD GRADE

232

3RD GRADE

219

CO

RR

IDO

R 5

15

CO

RR

IDO

R 1

11

CORRIDOR 3

13

TITLE 1

233

JANITOR

205

HALL

12

HALL

18

CLOSET

230STAIR 1

20

CHASE/DATA

205A

STORAGE

218

BR

EA

KO

UT

426

BREAKOUT

425

OPEN

OFFICE

410

ART/KILN

415

CONFERENCE

ROOM

413

LIBRARY

427

CSCT

422

SENSORY

402B

OT

402C

PT

221.1

CORRIDOR 4

14

BOILER

214

GYM

223

3/5 COATS

221D3/5

BREAKOUT

221A

3/5

STORAGE

221C

TECHNOLOGY

114

FRC

424

LIBRARY

113

FLAGSHIP

424A

PRINTING

406B

BICYCLE

STORAGE

228

24

23

22

21

20

19

66

5

4

3

13 15 16 17 18

T3-61

T3-41

T3-51

T3-31

RR J

402A

PRACTICE 2

211APRACTICE 1

211B

JANITOR

437

T7-11

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:1

0 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-1

01 22 19

TELECOMM

PLAN - FIRST

FLOOR -

OVERALL

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/16" = 1'-0"1

TELECOMM PLAN - FIRST FLOOR -OVERALL

1979

2008

1951

2018

20182018

2018

N

Page 2: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

CORRIDOR 6

16

4TH GRADE

430

BREAKOUT

306

JANITOR

432

BOYS

433

GIRLS

434

5TH GRADE

302

5TH GRADE

309

4TH GRADE

307

4TH GRADE

304

HVAC 1972

183

TITLE 1

308

BREAKOUT

304A

BREAKOUT

302A

ELEV HALL

431

ELEVATOR

417-2

SPEECH

435

CORRIDOR 7

17

24

23

22

21

20

19

6

5

4

3

13 15 16 17 18

T3-71

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:1

4 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-2

01 22 19

TELECOMM

PLAN -

SECOND

FLOOR -

OVERALL

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/16" = 1'-0"1

TELECOMM PLAN - SECOND FLOOR -OVERALL

1979 1951

N

Page 3: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

24

23

22

21

20

19

6

5

13 18

2

POS

2

FOR ELEVATOR CONTROL PANEL,COORDINATE LOCATION w/ ELEVATOR CONTRACTOR. TERMINATE CABLE IN DEMARC IN CHASE/DATA 205A.

MUSIC /

ORCH

204

MUSIC /

ORCH

211

SERVING

200

MULTIPURPOSE

414

GIRLS

210

BOYS

208

I.T.

416

ELEVATOR

417-1

HALL

436

GIRLS

206

BOYS

207

KITCHEN

PREP

203

CORRIDOR 3

13

JANITOR

205

HALL

12

HALL

18

CHASE/DATA

205A

ART/KILN

415

GYM

STORAGE

215

HALL

216

PE OFFICE

217A

CSCT

217B

CSCT

217C

BOILER

214

HALL

217

GYM

223

2

2

2

1

1

2

COORDINATE LOCATION w/ MECHANICAL

4

21

(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3, BY CABLING CONTRACTOR.

9

(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211.LOCATED @ ±9'-0" A.F.F. , BY CABLING CONTRACTOR.

7

(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.

LOCATED @ ±9'-8" A.F.F.

CA

M

120"

AF

F

LB

1

42" AFF

CAM

120" AFF

CAM

120" AFF

(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACES IN IT 416. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.

6

6

6

2

48" AFF

2

4

4

1

2

2

4

4

2222

2

2

4

4

4 4 4 4

PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE

PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE

1" EMT CONDUIT SLEEVE STUBBED 3" INTO CEILING SPACE ABOVE HALL 12 AND STUBBED 3" INTO HVAC 183A.

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

X

X

X

INDICATES WALL MOUNTED WORK AREA OUTLET.

INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.

INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.

X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS

LEGEND:

LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.

INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.

CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.

KEYED NOTES:

1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.

4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.

5. NOT USED

6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.

7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

X

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:2

5 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-3

01 22 19

TELECOMM

PLAN -

KITCHEN/MUSIC/

CORE

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/8" = 1'-0"1

TELECOMM PLAN - ENLARGED -MUSIC/DINING

1951

2018

N

Page 4: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

6

2

222

2

2AC2AC

2

2

2

2

2

4

4

4

4

2

4

4

2

AC

2

AC

2

4

(E)

2

(E)

2(E)

(E)

2

2(E)

2(E)

2

(E)

(E)

(4)-2" EMT CONDUIT SLEEVES BETWEEN CEILING SPACE ABOVE CORRIDOR 11 AND CEILING SPACE ABOVE HALL 12, BY CABLING CONTRACTOR.

ENTRANCE

404

1ST GRADE

403

K2

EXTENDED

402

SPECIAL ED

122

2ND GRADE

110

2ND GRADE

111

1ST GRADE

116

1ST GRADE

115

1ST GRADE

108

2ND GRADE

109

CORRIDOR 5

15

CORRIDOR 1

11

HALL

12

WOMENS

202

BREAKOUT

426

BREAKOUT

425

LIBRARY

427

SENSORY

402B

OT

402C

TECHNOLOGY

114

FRC

424

LIBRARY

113

FLAGSHIP

424A

22

(E)

2

(E)

2

2

(E)

4

4

4

4

1

1

1

11

1

1

1

1

44

4

4

4

4

4

4

4

4

4

4

2

4

2 1

2 1

2 1

2(E)

2(E)

(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.

9

(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN 2ND GRADE 111 AND ACCESSIBLE CEILING SPACE IN CORRIDOR 5, BY CABLING CONTRACTOR.

77

7

7

(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN CORRIDOR 5 AND ACCESSIBLE CEILING SPACE IN FIRST GRADE 115, BY CABLING CONTRACTOR.

(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN FIRST GRADE 116 AND ACCESSIBLE CEILING SPACE IN FIRST GRADE 115, BY CABLING CONTRACTOR.

9

9

(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN 2ND GRADE 111 AND CEILING SPACE IN CORRIDOR 5, BY CABLING CONTRACTOR.

LB

LB

LB

4

1

1

CONDUIT FED THROUGH NEW WALL FRAMING INTO ACCESSIBLE CEILING SPACE IN SPECIAL ED 122.

JANITOR

205

RR J

ENTRANCE

CONDUIT FED THROUGH NEW WALL FRAMING INTO ACCESSIBLE CEILING SPACE IN SECOND GRADE 112.

2ND GRADE

112

CAM

6

2AC

4

2AC

4

10

10

10

120" AFF

(E)

X

X

X

INDICATES WALL MOUNTED WORK AREA OUTLET.

INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.

INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.

X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS

LEGEND:

LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.

INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.

CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:KEYED NOTES:

1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.

4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.

5. NOT USED

6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.

7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

10. IN AREAS INDICATED, RELOCATE PATCH PANEL TERMINATIONS IN EXISTING DATA 205A TO IT 416. RETERMINATE ONTO NEW PATCH PANELS.

X

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:3

2 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-4

01 22 19

TELECOMM

PLAN -

NORTHWEST

AREA/LIBRARY

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/8" = 1'-0"1

TELECOMM PLAN - ENLARGED -NORTHWEST

1979

2018

N

Page 5: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

2

2

AC

2

AC

2

AC

2

AC4AC6AC2

2(E)

2

(E)

(E)

2

4

2

(E)

PRINCIPAL

407

LOUNGE

412

COUNSELOR

411

NURSE

409

RR M

406A

MAIL / WORK

408

RECEPTION

406

ENTRANCE

404

KINDERGARTEN

118KINDERGARTEN

119

KINDERGARTEN

120

KINDERGARTEN

121

OPEN

OFFICE

410

CONFERENCE

ROOM

413

PRINTING

406B

2(E)LB

2

2

2

2(E)

2

2

(E)

AC

2

2(E)

2

(E)

2

4

4

4

4

4 4

4

4

2

9

(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN CORRIDOR 1 AND ACCESSIBLE CEILING SPACE IN KINDERGARTEN 121, BY CABLING CONTRACTOR.

EXISTING (1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN KINDERGARTEN 118 AND ACCESSIBLE CEILING SPACE IN PRINTING 406B

7

7

8

7

7

77

CAM

CAM120" AFF

2(E)FOR FIRE ALARM CONTROL PANEL.COORDINATE LOCATION w/ ELECTRICAL AND FIRE ALARM CONTRACTOR.

(E)

120" AFF

(E)

10

10

10

10

10

10

10

10

10

(E)

(E)

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

X

X

X

INDICATES WALL MOUNTED WORK AREA OUTLET.

INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.

INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.

X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS

LEGEND:

LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.

INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.

CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.

KEYED NOTES:

1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.

4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.

5. NOT USED

6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.

7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

10. IN AREAS INDICATED, RELOCATE PATCH PANEL TERMINATIONS IN EXISTING DATA 205A TO IT 416. RETERMINATE ONTO NEW PATCH PANELS.

X

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:3

3 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-5

01 22 19

TELECOMM

PLAN - ADMIN

AREA

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/8" = 1'-0"1

TELECOMM PLAN - ENLARGEDADMIN/KINDERGARTEN

1979

2018

N

Page 6: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

5

4

3

13 15 16 17 18

2

2

(1)-4" EMT CONDUIT BETWEEN FIRST FLOOR AND SECOND FLOOR, BY CABLING CONTRACTOR.

2

2

(N) 2"x6" CABLE TRAY, BY CABLING CONTRACTOR.

2

2

2

2

2

2

3

2

2

1

1

2

2

3RD GRADE

423

BREAKOUT

219A

BREAKOUT

231

3/5

EXTENDED

221

5TH GRADE

234

3RD GRADE

232

3RD GRADE

219

CORRIDOR 3

13

TITLE 1

233

CLOSET

230STAIR 1

20

STORAGE

218

CSCT

422

PT

221.1

CORRIDOR 4

14

3/5 COATS

221D

3/5

BREAKOUT

221A

3/5

STORAGE

221C

RR G

221B

4

1

1

11

1

1

4

4

4

4

4

(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3, BY CABLING CONTRACTOR.

7

7

7

77

9

7 7

LB

4

CAM

MOUNT CAMERA TO BOTTOM OF CONCRETE CANOPY

CA

M

66

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

X

X

X

INDICATES WALL MOUNTED WORK AREA OUTLET.

INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.

INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.

X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS

LEGEND:

LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.

INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.

CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.

KEYED NOTES:

1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.

4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.

5. NOT USED

6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.

7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

X

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:3

9 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-6

01 22 19

TELECOMM

PLAN -

NORTHEAST

AREA

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/8" = 1'-0"1

TELECOMM PLAN - ENLARGED -NORTHEAST

1951

2018

N

Page 7: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

20

19

6

55

4

3

13 15 16 17 18

(1)-4" EMT CONDUIT BETWEEN FIRST FLOOR AND SECOND FLOOR, BY CABLING CONTRACTOR.

22

2 2

2

2

2

2

2

3

CORRIDOR 6

16

4TH GRADE

430

BREAKOUT

306

JANITOR

432

5TH GRADE

302

5TH GRADE

309

4TH GRADE

307

4TH GRADE

304

HVAC 1972

183

TITLE 1

308

STAIR 2

21

BREAKOUT

304A

BREAKOUT

302A

ELEV HALL

431

ELEVATOR

417-2

SPEECH

435

CORRIDOR 7

17

2

2

1

1

1" EMT CONDUIT SLEEVE STUBBED 3" INTO CEILING SPACE ABOVE HALL 12 AND STUBBED 3" INTO HVAC 183A.

11

11

1

1

2

2

2

2

2

COORDINATE LOCATION w/ MECHANICAL

6

5

5

5

5

LB

4

22

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

X

X

X

INDICATES WALL MOUNTED WORK AREA OUTLET.

INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.

INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.

X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS

LEGEND:

LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.

INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.

CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.

KEYED NOTES:

1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.

2. PROVIDE WIREMOLD RACEWAY FROM NEAREST CORRIDOR TO OUTLETS.

3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.

4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.

5. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

6. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.

X

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:4

4 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T3-7

01 22 19

TELECOMM

PLAN -

SECOND

FLOOR -

NORTHEAST

AREA

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

1/8" = 1'-0"1

TELECOMM PLAN - SECOND FLOOR -NORTHEAST/IT CLOSET 183A

1951

2018

N

Page 8: C:UsersJeffDocumentsHawthorne Elementary - … · 2019. 1. 28. · ANSI/TIA -526 -14 -C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published

19

5

I.T.

416

CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.

CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)

(2)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3

(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.

(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACES IN IT 416. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.

(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.

CORNING 2U FIBER OPTIC PATCH PANEL,PART# CCH-02U

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

ETHERNET SWITCH, BY OWNER

CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.

APC, SMT2200RM2UNCUNITERRUPABLE POWER SUPPLY (UPS)

CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

ETHERNET SWITCH, BY OWNER

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

ETHERNET SWITCH, BY OWNER

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

ETHERNET SWITCH, BY OWNER

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

ETHERNET SWITCH, BY OWNER

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.

(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211.LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

ETHERNET SWITCH, BY OWNER

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

ETHERNET SWITCH, BY OWNER

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2

ETHERNET SWITCH, BY OWNER

COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1

APC, SMT2200RM2UNCUNITERRUPABLE POWER SUPPLY (UPS)

1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:

ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.

2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.

3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.

4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.

5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.

6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.

7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.

8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.

PLAN NOTES:

DS

A,

P.C

.

CO

PY

RIG

HT

DRAWN BY:

PROJECT:

REVISIONS:

JG

2300 R

EG

EN

T S

T.,

Suite 2

07

Mis

soula

, M

T

59801

ph:

406.3

27.0

62

9fa

x:

406.5

41.9

881

access-c

onsultin

g.n

et

1/2

2/2

019 1

0:5

3:4

5 A

MY

:\2

018\ M

CP

S\H

aw

tho

rne E

lem

enta

ry\D

r aw

ings\R

evit\T

el e

com

m\H

aw

thorn

eE

lem

ent a

ry -

Tele

com

munic

ations -

Cabli n

g v

18.r

vt

T7-1

01 22 19

TELECOMM

ELEVATION -

IT 416

HA

WT

HO

RN

E S

CH

OO

L

2835 S

3rd

St

WM

issoula

, M

T 5

9804

10

0%

CO

NS

TR

UC

TIO

N D

OC

UM

EN

T S

ET

17-533

N

1/4" = 1'-0"1

TELECOMM PLAN - IT 4162

TELECOMM ELEVATION - IT 416