cts-temperature-/climatic- stress-screening-chambers · the latest generation with innovative...

4
The latest generation with innovative technique and future-oriented design. CTS-Temperature-/Climatic- Stress-Screening-Chambers Basic Equipment: capacitive Multi-Touch-Display in the front service-friendly capacitive humidity measurement system defined keys for elementary functions of the installation such as start/stop, fixed-value/automatic operation, interruption, light, etc. USB -Connection to save measuring data on USB Stick Ethernet – Interface/RS 232 – Interface 2 digital Out, to switch test specimen ON/OFF adjustable software-temperature-limiter min./max. shelf, stainless steel entry port Ø 50 mm on the right side single-hand operated door handle, lockable Your benefits: low consumption data minimum noise level extremely high temperature change rates user-friendly operation and programming uniform operation due to identical Multi-Touch-Display for all chamber sizes demineralized water system with level indicator temperature measuring with Pt 100 in air inlet and air outlet Service-friendly construction international standards are fulfilled (CE-Conformity) Screening Chambers with 5 K/min, 10 K/min and 15 K/min Test space capacity in Litres: 100 / 200 / 350 / 600 / 1000 / 1500 / 2000 Temperature range: -40° C / +180° C; -70° C / +180° C

Upload: others

Post on 12-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CTS-Temperature-/Climatic- Stress-Screening-Chambers · The latest generation with innovative technique and future-oriented design. CTS-Temperature-/Climatic-Stress-Screening-Chambers

The latest generation with innovative technique and future-oriented design.

CTS-Temperature-/Climatic-Stress-Screening-Chambers

Basic Equipment:

capacitive Multi-Touch-Display in the front

service-friendly capacitive humidity

measurement system

defined keys for elementary functions

of the installation such as start/stop,

fixed-value/automatic operation,

interruption, light, etc.

USB -Connection to save measuring data

on USB Stick

Ethernet – Interface/RS 232 – Interface

2 digital Out, to switch test specimen

ON/OFF

adjustable software-temperature-limiter

min./max.

shelf, stainless steel

entry port Ø 50 mm on the right side

single-hand operated door handle, lockable

Your benefits:

low consumption data

minimum noise level

extremely high temperature change rates

user-friendly operation and programming

uniform operation due to identical

Multi-Touch-Display for all chamber sizes

demineralized water system with level

indicator

temperature measuring with Pt 100 in air

inlet and air outlet

Service-friendly construction

international standards are fulfilled

(CE-Conformity)

Screening Chambers with 5 K/min, 10 K/min and 15 K/min

Test space capacity in Litres: 100 / 200 / 350 / 600 / 1000 / 1500 / 2000

Temperature range: -40° C / +180° C; -70° C / +180° C

Page 2: CTS-Temperature-/Climatic- Stress-Screening-Chambers · The latest generation with innovative technique and future-oriented design. CTS-Temperature-/Climatic-Stress-Screening-Chambers

Temperature-/Climatic-Stress-Screening-Chambers

Type TS -40/..., CS-40/...

TS -70/..., CS-70/...

Test space litres

Test space dimensions height mm, approx.

width mm, approx.

depth mm, approx.

Overall dimensions height mm, approx.

width mm, approx.

depth mm, approx.

Temperature Tests

Temperature range TS-40 /... CS-40 /... °C

TS-70 /... CS-70 /... °C

Temp. Change rate cooling TS-40 /... CS-40 /... K / min

acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min

Temp. Chang rate heating TS-40 /... CS-40 /... K / min

acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min

max. thermal load TS-40 /... CS-40 /... W

at +20°C TS-70 /... CS-70 /... W

Temperature fluctuation K

Climatic Test

Temperature range CS-40 /... CS-70 /... °C

Humidity range CS-40 /... CS-70 /... % r. F.

Dew point range I CS-40 /... CS-70 /... °C

Dew point range II CS-40 /... CS-70 /... °C

Humidity fluctuation I CS-40 /... CS-70 /... % r. F.

Humidity fluctuation II CS-40 /... CS-70 /... % r. F.

Temperature fluctuation CS-40 /... CS-70 /... K

Nominal voltage

Nominal power TS-40 /... kW, approx.

CS-40 /... kW, approx.

TS-70 /... kW, approx.

CS-70 /... kW, approx.

Refrigeration unit

Weight TS-40 /... CS-40 /... kg, approx.

TS-70 /... CS-70 /... kg, approx.

Noise level dB(A)

-70/100-5

100

500

500

400

1630

770

860

-70/+180

8

6

1200

6,5

300<60

-70/100-10

100

500

500

400

1630

770

860

-70/+180

10

10

2000

7,5

air cooled

350<60

-70/200-15

200

750

650

400

1800

920

1345

-70/+180

15

15

5000

10 bis 98

17

650<62

-40/200-5

-70/200-5

200

750

650

400

1800

920

1345

-40/+180

-70/+180

5

6

8

8

3500

3500

9,3

10,4

12

12

air cooled

500

550<58

-40/200-10

-70/200-10

200

750

650

400

1800

920

1345

-40/+180

-70/+180

10

11

12

12

5000

4000

13,4

14,5

16,6

16,6

600

650<62

-40/280-15

280

720

650

615

2080

920

2165

-40/+180

19

16

5000

10 bis 95

15,1

15,1

800

<63

-40/350-5

-70/350-5

350

750

650

720

1800

920

1665

-40/+180

-70/+180

5

5

8

8

3500

3500

9,3

10,4

11,8

11,8

600

650<58

-40/350-10

-70/350-10

350

750

650

720

1800

920

1665

-40/+180

-70/+180

10

10

10

10

5000

5000

13,4

13,4

16,6

16,6

700

750<62

-70/350-15

350

750

650

720

1800

920

1665

-70/+180

15

15

6000

10 bis 98

20,4

18,3

750<62

-40/600-5

-70/600-5

600

850

850

830

1900

1120

1875

-40/+180

-70/+180

6

7

6

6

4500

5000

11

12,1

14,2

14,2

700750

<62

-40/600-10

-70/600-10

600

850

850

830

1900

1120

1875

-40/+180

-70/+180

10

10

10

10

7000

5000

15,5

15,5

13

13

water cooled

800900

<62

-40/500-15

-70/500-15

500

820

850

725

2170

1120

2375

-40/+180

-70/+180

15

15

15

15

7000

8000

24,4

24,4

25,6

25,6

8001000

<68

-40/1000-5

-70/1000-5

1000

900

1000

1100

1950

1270

2245

-40/+180

-70/+180

5

5

6

6

5200

5500

13,3

13,2

16,4

16,4

water cooled

850

900<62

-40/1000-10

-70/1000-10

1000

900

1000

1100

1950

1270

2245

-40/+180

-70/+180

10

10

10

10

8000

7500

20,9

20,9

15,4

15,4

1000

1000<65

-40/810-15

-70/810-15

810

870

1000

900

2230

1270

2645

-40/+180

-70/+180

15

15

15

15

8000

8000

23,7

23,7

27,3

27,3

1100

1800<73

-40/1500-5

-70/1500-5

1500

900

1000

1600

1950

1270

2745

-40/+180

-70/+180

5

5

5

5

5000

5500

13,2

13,2

16,1

16,1

1000

1100<64

-40/1500-10

-70/1500-10

1500

900

1000

1600

1950

1270

2745

-40/+180

-70/+180

10

10

10

10

8000

8000

20,9

20,9

20,2

20,2

1150

1300<70

-40/1250-15

-70/1250-15

1250

870

1000

1400

2230

1270

3142

-40/+180

-70/+180

15

15

15

15

8000

8000

30,8

30,8

38,1

38,1

1350

1500<73

All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options.

Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.

Options:

add. Entry ports Ø 50 mm,

80 mm und 125 mm

add. Shleves

panoramic window, multiple glazed, sized

570 x 710 mm, < 200 ltr., incl. LED-light

hand-holes in the door

add. Pt 100 for temperature measuring

on test specimen reversible to controller

function

air dryer system

mobile design

air/water cooled refrigeration unit

temperature protection for test specimen

CID software for programming and

documentation

variable air speed in the test space

RS 232 interface changeable to USB

notch

Control: Multi-Touch-Display with

integrated program controller

Test Space:: Stainless steel grade 1.4301

Refrigerants: environmental friendly refrigerants

Humidity system: (only type CS) capacitive measuring

5 K/min. 10 K/min. 15 K/min.

<± 0,3 <± 0,3 <± 0,3

400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz

water cooled

+10 bis +95

10 bis 98

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

+10 bis +95

10 bis 98

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

+10 bis +95

10 bis 95

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

Page 3: CTS-Temperature-/Climatic- Stress-Screening-Chambers · The latest generation with innovative technique and future-oriented design. CTS-Temperature-/Climatic-Stress-Screening-Chambers

Temperature-/Climatic-Stress-Screening-Chambers

Type TS -40/..., CS-40/...

TS -70/..., CS-70/...

Test space litres

Test space dimensions height mm, approx.

width mm, approx.

depth mm, approx.

Overall dimensions height mm, approx.

width mm, approx.

depth mm, approx.

Temperature Tests

Temperature range TS-40 /... CS-40 /... °C

TS-70 /... CS-70 /... °C

Temp. Change rate cooling TS-40 /... CS-40 /... K / min

acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min

Temp. Chang rate heating TS-40 /... CS-40 /... K / min

acc. IEC 60068-3-5 TS-70 /... CS-70 /... K / min

max. thermal load TS-40 /... CS-40 /... W

at +20°C TS-70 /... CS-70 /... W

Temperature fluctuation K

Climatic Test

Temperature range CS-40 /... CS-70 /... °C

Humidity range CS-40 /... CS-70 /... % r. F.

Dew point range I CS-40 /... CS-70 /... °C

Dew point range II CS-40 /... CS-70 /... °C

Humidity fluctuation I CS-40 /... CS-70 /... % r. F.

Humidity fluctuation II CS-40 /... CS-70 /... % r. F.

Temperature fluctuation CS-40 /... CS-70 /... K

Nominal voltage

Nominal power TS-40 /... kW, approx.

CS-40 /... kW, approx.

TS-70 /... kW, approx.

CS-70 /... kW, approx.

Refrigeration unit

Weight TS-40 /... CS-40 /... kg, approx.

TS-70 /... CS-70 /... kg, approx.

Noise level dB(A)

-70/100-5

100

500

500

400

1630

770

860

-70/+180

8

6

1200

6,5

300<60

-70/100-10

100

500

500

400

1630

770

860

-70/+180

10

10

2000

7,5

air cooled

350<60

-70/200-15

200

750

650

400

1800

920

1345

-70/+180

15

15

5000

10 bis 98

17

650<62

-40/200-5

-70/200-5

200

750

650

400

1800

920

1345

-40/+180

-70/+180

5

6

8

8

3500

3500

9,3

10,4

12

12

air cooled

500

550<58

-40/200-10

-70/200-10

200

750

650

400

1800

920

1345

-40/+180

-70/+180

10

11

12

12

5000

4000

13,4

14,5

16,6

16,6

600

650<62

-40/280-15

280

720

650

615

2080

920

2165

-40/+180

19

16

5000

10 bis 95

15,1

15,1

800

<63

-40/350-5

-70/350-5

350

750

650

720

1800

920

1665

-40/+180

-70/+180

5

5

8

8

3500

3500

9,3

10,4

11,8

11,8

600

650<58

-40/350-10

-70/350-10

350

750

650

720

1800

920

1665

-40/+180

-70/+180

10

10

10

10

5000

5000

13,4

13,4

16,6

16,6

700

750<62

-70/350-15

350

750

650

720

1800

920

1665

-70/+180

15

15

6000

10 bis 98

20,4

18,3

750<62

-40/600-5

-70/600-5

600

850

850

830

1900

1120

1875

-40/+180

-70/+180

6

7

6

6

4500

5000

11

12,1

14,2

14,2

700750

<62

-40/600-10

-70/600-10

600

850

850

830

1900

1120

1875

-40/+180

-70/+180

10

10

10

10

7000

5000

15,5

15,5

13

13

water cooled

800900

<62

-40/500-15

-70/500-15

500

820

850

725

2170

1120

2375

-40/+180

-70/+180

15

15

15

15

7000

8000

24,4

24,4

25,6

25,6

8001000

<68

-40/1000-5

-70/1000-5

1000

900

1000

1100

1950

1270

2245

-40/+180

-70/+180

5

5

6

6

5200

5500

13,3

13,2

16,4

16,4

water cooled

850

900<62

-40/1000-10

-70/1000-10

1000

900

1000

1100

1950

1270

2245

-40/+180

-70/+180

10

10

10

10

8000

7500

20,9

20,9

15,4

15,4

1000

1000<65

-40/810-15

-70/810-15

810

870

1000

900

2230

1270

2645

-40/+180

-70/+180

15

15

15

15

8000

8000

23,7

23,7

27,3

27,3

1100

1800<73

-40/1500-5

-70/1500-5

1500

900

1000

1600

1950

1270

2745

-40/+180

-70/+180

5

5

5

5

5000

5500

13,2

13,2

16,1

16,1

1000

1100<64

-40/1500-10

-70/1500-10

1500

900

1000

1600

1950

1270

2745

-40/+180

-70/+180

10

10

10

10

8000

8000

20,9

20,9

20,2

20,2

1150

1300<70

-40/1250-15

-70/1250-15

1250

870

1000

1400

2230

1270

3142

-40/+180

-70/+180

15

15

15

15

8000

8000

30,8

30,8

38,1

38,1

1350

1500<73

All figures are average values which have been obtained at a temperature of +25°C, without test specimen, without thermal load and without options.

Other chamber sizes and options on request. We reserve the right to make modifications due to technical development.

Options:

add. Entry ports Ø 50 mm,

80 mm und 125 mm

add. Shleves

panoramic window, multiple glazed, sized

570 x 710 mm, < 200 ltr., incl. LED-light

hand-holes in the door

add. Pt 100 for temperature measuring

on test specimen reversible to controller

function

air dryer system

mobile design

air/water cooled refrigeration unit

temperature protection for test specimen

CID software for programming and

documentation

variable air speed in the test space

RS 232 interface changeable to USB

notch

Control: Multi-Touch-Display with

integrated program controller

Test Space:: Stainless steel grade 1.4301

Refrigerants: environmental friendly refrigerants

Humidity system: (only type CS) capacitive measuring

5 K/min. 10 K/min. 15 K/min.

<± 0,3 <± 0,3 <± 0,3

400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz 400 V +6% –10%, 3/N, 50 Hz

water cooled

+10 bis +95

10 bis 98

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

+10 bis +95

10 bis 98

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

+10 bis +95

10 bis 95

+7 bis +94

–10 bis +7

<± 1,5

<± 3

<± 0,3

Page 4: CTS-Temperature-/Climatic- Stress-Screening-Chambers · The latest generation with innovative technique and future-oriented design. CTS-Temperature-/Climatic-Stress-Screening-Chambers

CTS GmbH | Lotzenäcker 21 | D-72379 Hechingen | GermanyTel.: +49 (0) 74 71/98 50-0 | Fax: +49 (0) 74 71/98 [email protected] | www.cts-umweltsimulation.de

How to find us:

Exit

Exit