Counter Sub Counter RRC.FailConnEstab.Cong VS.RRC.Rej.Power.Cong VS.RRC.Rej.UL.CE.Cong VS.RRC.Rej.DL.CE.Cong VS.RRC.Rej.Code.Cong VS.RRC.Rej.ULIUBBandCong VS.RRC.Rej.DLIUBBandCong VS.RRC.FailConnEstab VS.RRC.Rej.RL.Fail RRC.FailConnEstab.Cong VS.RRC.Rej.AAL2.Fail CS RAB Setup Counter Level1 Sub Counter Level2 VS.RAB.FailEstabCS.RNL VS.RAB.FailEstCS.Unsp VS.RAB.FailEstCS.RIPFail VS.RAB.FailEstCS.Relo VS.RAB.FailEstabCS.RNL.Other VS.RAB.FailEstabCS.TNL VS.RAB.FailEstabCS.other.CELL PS RAB Setup Counter Level1 Sub Counter Level2 VS.RAB.FailEstPS.RNL VS.RAB.FailEstPS.Unsp VS.RAB.FailEstPS.RIPFail VS.RAB.FailEstPS.Par VS.RAB.FailEstPS.Relo VS.RAB.FlEstPS.RNL.Other VS.RAB.FailEstPS.TNL VS.RAB.FailEstPS.NResAvail RRC Setup RRC.FailConnEstab.NoRep ly

Upload: ronnydaya

Post on 31-Jan-2016

178 views

Category:

Documents


23 download

DESCRIPTION

Cdr Guideline

TRANSCRIPT

Page 1: Cssr Cdr Guideline v1.1

Counter Sub Counter

RRC.FailConnEstab.Cong VS.RRC.Rej.Power.Cong

VS.RRC.Rej.UL.CE.Cong

VS.RRC.Rej.DL.CE.Cong

VS.RRC.Rej.Code.Cong

VS.RRC.Rej.ULIUBBandCong

VS.RRC.Rej.DLIUBBandCong

VS.RRC.FailConnEstab VS.RRC.Rej.RL.Fail

RRC.FailConnEstab.Cong

VS.RRC.Rej.AAL2.Fail

RRC.FailConnEstab.NoReply

CS RAB SetupCounter Level1 Sub Counter Level2

VS.RAB.FailEstabCS.RNL VS.RAB.FailEstCS.Unsp

VS.RAB.FailEstCS.RIPFail

VS.RAB.FailEstCS.Relo

VS.RAB.FailEstabCS.RNL.Other

VS.RAB.FailEstabCS.TNL

VS.RAB.FailEstabCS.other.CELL

PS RAB SetupCounter Level1 Sub Counter Level2

VS.RAB.FailEstPS.RNL VS.RAB.FailEstPS.Unsp

VS.RAB.FailEstPS.RIPFail

VS.RAB.FailEstPS.Par

VS.RAB.FailEstPS.Relo

VS.RAB.FlEstPS.RNL.Other

VS.RAB.FailEstPS.TNL

VS.RAB.FailEstPS.NResAvail

RRC Setup

Page 2: Cssr Cdr Guideline v1.1

VS.RAB.FailEstabPS.Other.Cell

CS Call DropCounter Level1 Sub Counter Level2

VS.RAB.Loss.CS.RF VS.RAB.Loss.CS.RF.RLCRst

VS.RAB.Loss.CS.RF.ULSync

VS.RAB.Loss.CS.RF.UuNoReply

VS.RAB.Loss.CS.RF.Oth

VS.RAB.Loss.CS.Abnorm VS.RAB.RelReqCS.OM

VS.RAB.RelReqCS.UTRANgen

VS.RAB.RelReqCS.RABPreempt

VS.RAB.Loss.CS.Aal2Loss

VS.RAB.Loss.CS.Congstion.CELL

VS.Call.Drop.CS.Other

Counter Level1 Sub Counter Level2

VS.RAB.Loss.PS.Abnorm VS.RAB.RelReqPS.OM

VS.RAB.RelReqPS.RABPreempt

VS.RAB.Loss.PS.GTPULoss

VS.RAB.Loss.PS.Congstion.CELL

VS.Call.Drop.PS.Other

VS.RAB.Loss.PS.RF VS.RAB.Loss.PS.RF.RLCRst

VS.RAB.Loss.PS.RF.ULSync

VS.RAB.Loss.PS.RF.UuNoReply

VS.RAB.Loss.PS.RF.Oth

Counter Level1 Sub Counter Level2

VS.SRELOC.FailPrep.IRATCSOut VS.SRELOC.Fail.IRATCSOutNRpl

VS.SRELOC.Fail.IRATCSOutCanc

VS.SRELOC.Fail.IRATCSOutTexp

VS.SRELOC.Fail.IRATCSOutTfai

VS.SRELOC.Fail.IRATCSOutTOve

VS.IRATHO.PrepFailCSOut.UkwnRNC

VS.IRATHO.PrepFailCSOut.NoRsrc

VS.IRATHO.PrepFaiCSInTgtOveL

VS.IRATHO.FailCSOut.RNC VS.IRATHO.FailCSOut.CfgUnRNC

VS.IRATHO.FailCSOut.PhyFaRNC

PS IRAT Handover FailCounter Level1 Sub Counter Level2

PS Call Drop

CS IRAT Handover Fail

VS.IRATHO.PrepFailCSOutReqinfnotavai

Page 3: Cssr Cdr Guideline v1.1

VS.IRATHO.PSOut.FailPS VS.IRATHO.PSOut.CfgUnsup

VS.IRATHO.PSOut.PhyCHFail

VS.IRATHO.PSOut.Unpec

VS.IRATHO.PSOut.NoReply

Page 4: Cssr Cdr Guideline v1.1

Sub CounterLevel3 Sub CounterLevel4

VS.RAB.FailEstabCS.Cong VS.RAB.FailEstCs.Power.Cong

VS.RAB.FailEstCs.Code.Cong

VS.RAB.FailEstab.CS.DLIUBBand.Cong

VS.RAB.FailEstab.CS.ULIUBBand.Cong

VS.RAB.FailEstCs.ULCE.Cong

VS.RAB.FailEstCs.DLCE.Cong

VS.RAB.FailEstabCS.Unsp.Other

VS.RAB.FailEstCS.RIPFail

VS.RAB.FailEstCS.Relo

VS.RAB.FailEstabCS.RNL.Other

VS.RAB.FailEstabCS.TNL

VS.RAB.FailEstabCS.other.CELL

Sub Counter Level3

VS.RAB.FailEstPs.Power.Cong

VS.RAB.FailEstPs.Code.Cong

VS.RAB.FailEstab.PS.DLIUBBand.Cong

VS.RAB.FailEstab.PS.ULIUBBand.Cong

VS.RAB.FailEstPs.ULCE.Cong

VS.RAB.FailEstPs.DLCE.Cong

VS.RAB.FailEstabPS.Unsp.Other

VS.RAB.FailEstPS.RIPFail

VS.RAB.FailEstPS.Par

VS.RAB.FailEstPS.Relo

VS.RAB.FlEstPS.RNL.Other

VS.RAB.FailEstPS.TNL

VS.RAB.FailEstPS.NResAvail

Page 5: Cssr Cdr Guideline v1.1

VS.RAB.FailEstabPS.Other.Cell

Sub Counter Level3

VS.RAB.RelReqPS.OM

VS.RAB.RelReqPS.RABPreempt

VS.RAB.Loss.PS.GTPULoss

VS.RAB.Loss.PS.Congstion.CELL

VS.Call.Drop.PS.Other

VS.RAB.Loss.PS.SRBReset

VS.RAB.Loss.PS.TRBReset

VS.RAB.Loss.PS.RF.ULSync

VS.RAB.Loss.PS.RF.UuNoReply

VS.RAB.Loss.PS.RF.Oth

Page 6: Cssr Cdr Guideline v1.1

Analysis Ac Input Tools

Counter Analysis

Abnormal

Cluster MeasuResult

TOP Cell

M2000/LMT

MeasuResult PRS

LMT

Analysis Sub Action

Cluster MeasuResult,CFGMML

M2000/PRS/Nastar

Subsystem exception

M2000/PRS/Nastar

TOP N CellID

TOP N Cell ID,RNC MML

RNC MM,check Iu-CS,Iub,Iur interface configuration

Page 7: Cssr Cdr Guideline v1.1

Counter Analysis

TOP Cell

LMT

Cell LMT

Cell PRS

RNC MM,check Iu-CS,Iub,Iur interface configuration

PRS,RNC/NodeB LMT、

M2000

Page 8: Cssr Cdr Guideline v1.1

Counter Analysis

TOP Cell

TOP Cell PRS

MeasuResult

PRS,RNC/NodeB LMT、

M2000

PRS,RNC LMT

Page 9: Cssr Cdr Guideline v1.1

Counter Analysis

TOP Cell

MeasuResult

MR NASTARV6R8

Top Cell

PCHR Analysis

CHR

CHR

PRS,RNC LMT

M2000,UMAT

TOP User Analysis

PCHR Analyzer

TOP Terminal Analyis

PCHR Analyzer

Page 10: Cssr Cdr Guideline v1.1

PCHR Analysis

CHR

CHR

CM Analysis

PCHR Analyzer

Special HO Fail Analysis

PCHR Analyzer,M2

000,LMT

Page 11: Cssr Cdr Guideline v1.1

if VS.RAB.Loss.CS.RF.Oth>10%

TOP Cell Alarm Check

Analysis Action(Level 1)

IF ClusterVS.RAB.Loss.CS.Abnorm>10%

if subsystem CDR > 3%,and denominator >10000 ; (VS.RAB.Rel.Abnorm.AMR.SPU/(VS.RAB.Rel.Abnorm.AMR.SPU+VS.RAB.Rel.Norm.AMR.SPU)))

Check TOP cell neighbor handover radius

Check if RC.AttConnEstab.EmgCall/( RRC.AttConnEstab.OrgConvCall + RRC.AttConnEstab.TmConvCall + RRC.AttConnEstab.EmgCall)>50%[Option]TOP cell transmission configuration

Page 12: Cssr Cdr Guideline v1.1

[Option]TOP cell clock check

TOP cell interference

TOP cell 3G/2G HO Check

[Option]TOP cell transmission configuration

Page 13: Cssr Cdr Guideline v1.1

TOP cell 3G/2G HO Check

ClusterVS.RAB.Loss.CS.Abnorm>20%

Top cell at border of RNCs

Page 14: Cssr Cdr Guideline v1.1

Top cell at border of RNCs

MR Coverage Analysis

IOS Aanalyis

filter if Top 10 IMSI CallDrop >10%(Total Call Drop)

[option] check if Top N IMSI drop have same signalling procedure

filter if Top 5 IMEI CallDrop >10%(Total Call Drop)

Page 15: Cssr Cdr Guideline v1.1

按文档统计与压模相关的掉话占总的语音掉话的比例,如果超过30%

统计原因为no_active_set_cmp的掉话话单中出现频度最高的TOP10小区,查看TOP10小区中是否有小区90%的软切换失败都是向特定小区切换失败的,如果是,进入下一级动作

Page 16: Cssr Cdr Guideline v1.1

VS.Call.Drop.CS.OtherEscalate to TSEscalate to TS

RNC Alarm

check coverage scene

DSP AAL2PATH/IPPATH check path if available

check if AAL2RT or IPRT is configured

Analysis Action(Level 2)

VS.RAB.RelReqCS.OM

VS.RAB.RelReqCS.UTRANgen VS.RAB.RelReqCS.RABPreempt VS.RAB.Loss.CS.Aal2Loss VS.RAB.Loss.CS.Congstion.CELL

NodeB Alarm:i. Cell unavailable ii. Transmission Alarmiii. DSP or CPU alarm,iv. Clock alarm or RF alarm;

change to MOD LOCELL: RADIUS=29000, HORAD=0;

Page 17: Cssr Cdr Guideline v1.1

NodeB LMT DSP CLKSTAT or LST CLKRECORD

if TOP Cell CS HO Prep SR<99%

a)For ATM:E1Test:if AAL2PATH Down or BER>1%,Check transmission qualityb)For IP:PingTest: if PacketLoss>1%Check transmission quality

if clock status (FREE),escalate to RAN/BSS if RTWP (>-96dBm),check according to Interference guidelinei check traffic if highii check if have RF module alarmiii trace RTWP in LMT,compare primary and secondary RTWP to check if interneliiii using LMT frequency scan Functionto check if external interference

Check HO_MC_MEAS_BEYOND_UE_CAP_SWITCH (CORRMALOGSWITCH)

Check HO_MC_SIGNAL_SWITCH (CORRMALOGSWITCH)

if CS HO relocation <98%,and IRATHO.FailOutCS.PhyChFail >50%

Page 18: Cssr Cdr Guideline v1.1

Escalate to TS

Check if miss inter RNC cell neighborcheck CS HO inter RNC

if CS HO relocation <98%,and IRATHO.FailOutCS.PhyChFail >50%

if CS HO relocation <98%, and if IRATHO.FailOutCS.CfgUnsupp >20%

Check if enable 2G->3G HO,should close SET RRCTRLSWITCH: RSVDPARA1= RsvdBit1_BIT17=0;

Check if configure Iur between RNCs,propose configure Iur

Page 19: Cssr Cdr Guideline v1.1

check CS HO inter RNC

check CS Relocation inter RNC

Escalated to TS

Escalated to TS

In Nastar “Topic Fuction”->”UMTS Coverage data task”caculate TOP cell EcNo,RSCP,Tp chart;

Escalated to TS

Page 20: Cssr Cdr Guideline v1.1

说明掉话跟压模有关,需要优化连续覆盖区域小区的压模参数,降低小区异频/异系统起压模门限,减少起压模次

a) 通过M2000查看这两个小区所在NodeB是否有异常告警(例如时钟、通道、DSP和射频告警),如果有需要先处理异常告警。

b) (可选)对两个小区所在站点进行时钟核查。c) (可选)利用RNC维护台小区性能监测中的节点同步功能(如下图)检查这两个小区的Iub时延,如果时延相差超过SET DPUCFGDATA中 FPMDCCOMBINEDELAYVALUE设置值(基线为20ms),修改上行FP合并时延等于两小区Iub时延差+20ms。

d) 如果这两个小区没有异常告警,Iub时延也正常,可以尝试修改源小区相对目标小区的CIO(ADD/MOD INTRAFREQNCELL: CIOOffset=10),如果修改后有效,说明切换失败是信号突变引起的;反之,需要把CIO改回0。

Page 21: Cssr Cdr Guideline v1.1

Check SOP Alarm infoCheck Iu Transmission.

Escalate to TS

check if the CDR related to alarm time

Analysis Action(Level 3) Analysis Action(Level 4)

[Option]Chenk if CS_IUUP_V2_SUPPORT_SWITCH(CORRMALOGSWITCH) matach with CN side TFO/TrFO

[Option]Check if security mode is matched between CN and RNC CS&PS.(RNC,SET UEA)

Check if CFG_DL_BLIND_DETECTION_SWITCH (CORRMALOGSWITCH) open, and close to monitor

Alarm Check SOP,

Page 22: Cssr Cdr Guideline v1.1

change to close (0)

change to close (0)

check if 2G TCH/SD block rate >1%

ii. Check if 3G to 2G CIO is 0

IF IRATHO.FailRelocPrepOutCS.UKnowRNC

i. check if RNC and 2GBSC :PLMN,LAC、BSIC are matched

ii. Check if RNC,3G MSC and 2G BSC: PLMN、LAC are matced

iii. If 2G/3G don't have same MSC,check if 2G side CN configure 3G LAC

IF IRATHO.FailRelocPrepOutCS.ReloNoSup or IRATHO.FailRelocPrepOutCS.TgtFail

i. check 2G BSC and CN if enable 3G HO in(Inter-RAT In BSC Handover Enable)

ii. Check if CNs direction enable

check if miss 2G Neighbor(better coverage)

check if cell-cell neighbor; VS.IRATHO.FailOutCS.UEF.N

i. check if RNC side 2G cell info is matched with BSC side

Page 23: Cssr Cdr Guideline v1.1

iii. Check 2GBTS alarm(Clock)

Iur interface configuration check

check if cell-cell neighbor; VS.IRATHO.FailOutCS.UEF.N

iv. Check 3GNodeB Clock status, if CS HO relocation <50%, but prepare OK, mostly due to this reason

v. check if 2G cell have interference,if interference impact performance (RMV GSMNCELL)vi. ADD CELLINTERRATHOCOV: TargetRatCsThd=16, Try to improve the TargetRatCsThd.

check if cell-cell neighbor; VS.IRATHO.FailOutCS.UEF.N

a) check if 3G RNC,2G BSC cell security mode is matched.(if 2G no security,SET RRCTRLSWITCH: PROCESSSWITCH=SYS_HO_OUT_CIPHER_SWITCH-1&SYS_HO_CIPHER_CONFIG-0)

[Option]Check 2G cellFrequencyList if correct

Check ifVS.SHO.SuccRLSetupIur.Rx/VS.SHO.AttRLSetupIur.Tx<99.5%VS.SHO.SuccRLAddIur.Rx/VS.SHO.AttRLAddIur.Tx<99.5%

a) SET CORRMALGOSWITCH: CmpSwitch=CMP_IUR_SHO_DIVCTRL_SWITCH-1 if NRNC is NSN

Page 24: Cssr Cdr Guideline v1.1

a) Porpose configure Iur

Check ifVS.SHO.SuccRLSetupIur.Rx/VS.SHO.AttRLSetupIur.Tx<99.5%VS.SHO.SuccRLAddIur.Rx/VS.SHO.AttRLAddIur.Tx<99.5%

b) if VS.SHO.FailRLSetupIur.TransCongRx or VS.SHO.FailRLRecfgIur.CongTx >20%, check Iur configuration

c) if VS.SHO.FailRLSetupIur.HW.Rx or VS.SHO.FailRLSetupIur.CfgURx >20% ,escalated to TS

if VS.SRELOC.SuccExec.UENonInvCS.RNC/VS.SRELOC.AttExec.UENonInvCS.RNC <60%, then SET SRNSR: SrnsRabCnDomainType=NRT

(RELOC.SuccPrepUEInvolCS/RELOC.AttPrepUEInvolCS)*(VS.SRELOC.SuccExec.UEInvCS.RNC/VS.SRELOC.AttExec.UEInvCS.RNC)<80

b) if can't configure Iur ,Escalate to TS

if TOP Cell,MR count(EcNo<-14dB or RSCP<-110dBm)>20%,need RF optimization

if TOP Cell (RSCP>-85dBm and EcNo<-14dB)>20%,perhapes pilot pollution,need RF optimization

Page 25: Cssr Cdr Guideline v1.1

a) 对异频异系统共存的小区,检查SET HOCOMM: CoexistMeasThdChoice参数配置,在异频、异系统共存时哪个2D/2F参数有效并修改之(例如共存时异系统的2D/2F有效,则修改小区异系统2D/2F参数)

b) 对只有异频邻区或异系统邻区的小区,修改这些小区的异频或异系统压模参数

Page 26: Cssr Cdr Guideline v1.1

Output Action

Alarm handle result

Alarm handle result

Page 27: Cssr Cdr Guideline v1.1
Page 28: Cssr Cdr Guideline v1.1
Page 29: Cssr Cdr Guideline v1.1

PCHR过滤后的数据,语音掉话TOP10 IMSI信息

Page 30: Cssr Cdr Guideline v1.1

压模掉话占总掉话的比例,参数优化建议

Page 31: Cssr Cdr Guideline v1.1

Analysis Ac Input Tools

MeasResult,CFGMML

Analysis Sub Action

Subsystem abnormal

MeasResult PRS,OMStar

Top cell

PRS,OMStar

Page 32: Cssr Cdr Guideline v1.1

MeasResult

Top cell

PRS,OMStar单机版

Page 33: Cssr Cdr Guideline v1.1

MeasResult

MeasResult

PRS

CHR PCHRAnalyzer

Top cell

PRS,OMStar单机版

PRS,OMStar,NodeB LMT

MeasResult、RNC MML

PCHR Analysis

统计失败的TMSI分布(暂不执行)

Page 34: Cssr Cdr Guideline v1.1

CHR PCHRAnalyzer

PCHR Analysis

从过滤出的数据中统计失败的Tp

分布

从过滤出的数据中统计EcNo

Page 35: Cssr Cdr Guideline v1.1

Analysis Action(Level 1)

If Subsystem RRC SR <97%,denominator> 10000,then Subsystem abnormal

if VS.RRC.FailConnEstab.Cong >10%

Page 36: Cssr Cdr Guideline v1.1

if VS.RRC.Rej.RL.Fail>10%

if VS.RRC.Rej.TNL.Fail占RRC>10%

if VS.RRC.FailConnEstab.NoReply>10%

Page 37: Cssr Cdr Guideline v1.1

以上措施都未解决问题

if VS.RRC.FailConnEstab.NoReply>10%

如果有TMSI的接入失败较多(例如占总失败0.05%以上)

Page 38: Cssr Cdr Guideline v1.1

如果有20%以上的接入失败是Tp>20,这些小区或者是超远覆盖(在郊区),或者存在直放站。

统计失败时接入小区信令EcIo<-14dB(也即消息里的上报值小于21)的比例,如果超过30%,说明弱覆盖是接入失败主因

Page 39: Cssr Cdr Guideline v1.1

Analysis Action(Level 2)

Escalated to TS

Top cell capacity check

Page 40: Cssr Cdr Guideline v1.1

a) Check missing neighbor

TOP5 CellRL Fail

TOP5 Cell TNL Fail Check

b)Get VS.RRC.FailConnEstab.NoReply TOP5 Cell

Page 41: Cssr Cdr Guideline v1.1

提单

b)Get VS.RRC.FailConnEstab.NoReply TOP5 Cell

a) 首先与客户确认TMSI是否本网络的用户还是漫游用户,如果失败的TMSI非本网用户,也非MOCN和有效的漫游用户,统计所有这类TMSI的比例,跟客户交流澄清

b) 如果有TMSI一段时间内在某几个小区连续每隔1分钟或更短时间左右就RRC失败一次

Page 42: Cssr Cdr Guideline v1.1

a) 如果是超远覆盖,需要跟客户澄清

b) 如果确认接入失败小区下有直放站

a) 修改非RNC边界小区的同频重选启动门限IdleSintrasearch为127(MOD CELLSELRESEL: CellId=*****, IdleSintrasearch=127)

b) 修改TOP10小区信令FACH最大发射功率(提升2dB,MOD SCCPCH:CellID=*****, FACH1Id=4, FACH1MaxPower=30;)

Page 43: Cssr Cdr Guideline v1.1

Output

d)Expansion, PIC BSS

Analysis Action(Level 3) Analysis Action(Level 4)

VS.RRC.Rej.ULIUBBandCong

VS.RRC.Rej.DLIUBBandCong

a)check NCP/CCP if congestion, expansion

b)check if configure match with phsical BW;optimize active factor

c)change user GBR

VS.RRC.Rej.UL.CE.Cong

VS.RRC.Rej.DL.CE.Cong

a) if NodeB dynamic CE enable, try decrease GBR(SET USERGBR : UlGBR=D32, DlGBR=D32)

b) else expand CE

VS.RRC.Rej.Power.Cong, a)Check if CELLALGOSWITCH: NBMCacAlgoSwitch=HSDPA_UU_ADCTRL-0&HSUPA_UU_ADCTRL-b)1) if ul congestion :MOD CELLCAC: UlTotalEqUserNum=140 or more2) if dl congestion :MOD CELLALGOSWITCH: NBMDlCacAlgoSelSwitch=ALGORITHM_THIRD)3) then, expansion

VS.RRC.Rej.Code.Cong, if NodeB Dynamic Code,MOD CELLHSDPA set mannual,1 code.Else if RNC Dynamic Code,Mod CELLHSDPA auto,Max 15,Min 1

else expansion

Page 44: Cssr Cdr Guideline v1.1

RNC Alarm

TOP Cell Alarm Check RNC Alarm

Check IuB packet loss a)ATM,Check BERb)IP: Check Packet Loss Rate

TOP Cell Alarm Check RNC Alarm

TOP Cell Alarm CheckNodeB Alarm:

[Option]Check IuB packet loss a)ATM,Check BERb)IP: Check Packet Loss Rate

Else Escalate

NodeB Alarm:Check IUB AAL2PATH or IPPATH configruation

NodeB Alarm:i. Cell unavailable ii. Transmission Alarmiii. DSP or CPU alarm,iv. Clock alarm or RF alarm;

SPU/PIU Load Check if Subsystem VS.SPU.CPULOAD.MEAN >60%check if (RRC.AttConnEstab.IRATCelRes/ VS.RRC.AttConnEstab.Cell) or (IRATHO.AttIncCS/VS.RAB.AttEstabCS.Conv) too high,optimize Reselection or HOelse: Expansion

Page 45: Cssr Cdr Guideline v1.1

其它参数的核查和优化 按文档排查

FACH channel congestion: FACHch utl = (VS.MAC.CRNCIubBytesFACH.Tx-VS.MAC.CRNCIubBytes.PS.CCH.TX)*8/((60*<SP>*168*1/0.01)* VS.PCH.Bandwidth.UsageRate + (60*<SP>*168*2/0.01)*(1- VS.PCH.Bandwidth.UsageRate))

if FACHch utl >70% a)if (RRC.AttConnEstab.IRATCelRes/ VS.RRC.AttConnEstab.Cel)>20%,check 2G site downb) add SCCPCH

Interference check

i. 查询接入原因是否10,也即INTER_RAT_CELL_RESELECT,如果是,可能是频繁的2G/3G重选导致的,需要优化3G侧重选启动门限SsearchRat,减少乒乓

ii. 查询接入失败的小区是否是RNC边界的小区,如果是可以修改该小区同频重选门限

iii. 失败原因是否有资源拥塞,如果资源资源拥塞,可以参照TOP小区资源拥塞核查子动作进行相关检查

Page 46: Cssr Cdr Guideline v1.1

关闭直放站后在观察一下小区RRC接入指标,如果有改善,说明接入失败与直放站确有关系,需要关闭直放站如果直放站关闭前后,小区RRC接入指标变化较小,说明RRC接入失败与直放站没有关系

Page 47: Cssr Cdr Guideline v1.1

Action

Page 48: Cssr Cdr Guideline v1.1
Page 49: Cssr Cdr Guideline v1.1
Page 50: Cssr Cdr Guideline v1.1
Page 51: Cssr Cdr Guideline v1.1

Analysis Ac Input Tools

话统分析

MeasResult

Analysis Sub Action

[Option] Security mode check

CS_IUUP_V2_SUPPORT_SWITCH check

(可选)拆线消息悬置功能检查

PS+PS Combine License check

Subsystem abnormal

MeasResult PRS,OMStar

Top Cell Analysis

PRS,OMStar

Page 52: Cssr Cdr Guideline v1.1

话统分析

MeasResult

Top Cell Analysis

PRS,OMStar

Page 53: Cssr Cdr Guideline v1.1

话统分析

MeasResult

Top Cell Analysis

PRS,OMStar

Page 54: Cssr Cdr Guideline v1.1

话统分析

MeasResult

MeasResult

MeasResult

Top cell M2000/LMT

PCHRAnalyzer

Top Cell Analysis

PRS,OMStar

OMStar,M2000

PRS,OMStar,NodeB LMT

PCHR分析

TOP用户分析

最近一周2~3天工作日CHR

TOP终端分析

Page 55: Cssr Cdr Guideline v1.1

Analysis Action(Level 1)

Check CS VS PS, CN VS RNC Security mode:(MSC SET MapConfig,SGSN SET PMM ,RNC SET UEA) if matched

check CS_IUUP_V2_SUPPORT_SWITCH(SET CORRMALGOSWITCH)

向CN侧工程师了解MSC是否打开拆线消息悬置功能

If Subsystem RRC SR <97%,denominator> 10000,then Subsystem abnormal

if VS.RAB.FailEstabCS.Unsp>10%

Page 56: Cssr Cdr Guideline v1.1

if VS.RAB.FailEstabCS.Unsp>10%

if VS.RAB.FailEstabCS.IubFail>10%,(RAN12)

Page 57: Cssr Cdr Guideline v1.1

if VS.RAB.FailEstabCS.IubFail>10%,(RAN12)

IfVS.RAB.FailEstabCS.TNL

Page 58: Cssr Cdr Guideline v1.1

TOP IOS Analysis

IfVS.RAB.FailEstabCS.TNL

If VS.RAB.FailEstCS.RIPFail(R12: VS.RAB.FailEstabCS.UuFail)>10%

如果有TOP10的IMSI的接入失败较多(例如占总失败10%以上)

如果某类型号终端接入失败占总接入失败的10%以上

Page 59: Cssr Cdr Guideline v1.1

check PS+PS License

Escalated

Analysis Action(Level 2)

if open ,support Iuup ver2,Check CN side if open TFO/TrFO fuction,should be matched with RNC

如果打开,要求CN工程师关闭该功能

Top5 cell capacity check

Page 60: Cssr Cdr Guideline v1.1

Top5 cell capacity check

执行TOP5小区Iub Fail核查

Page 61: Cssr Cdr Guideline v1.1

Check Top Cell TNL Fail

执行TOP5小区Iub Fail核查

Page 62: Cssr Cdr Guideline v1.1

Check Top Cell TNL Fail

a) Check Missing Neighbor

b) VS.RAB.FailEstCS.RIPFail TOP5 Cell

参见文档进行

提单

提单

b) (R12 Support ) VS.RAB.FailEstabCS.RBIncCfg or VS.RAB.FailEstabCS.RBCfgUnsup>5%

(可选)检查TOP10 IMSI的接入流程是否一致,如果一致,在提单中说明

Page 63: Cssr Cdr Guideline v1.1

Output

ii. Else, add new pathDisable 2G->3G handover

Analysis Action(Level 3) Analysis Action(Level 4)

if (VS.RAB.FailEstabCS.Unsp –VS.RAB.FailEstabCS.Cong)>5%, Check AAL2 CID Congestion : if ANIQAAL2.Est.RLC.NoCID.Tx

or VS.QAAL2.Est.RLC.NoCID.Rx>1

0

i.LST ADJNODE,check adj Node Numii.LST AAL2PATH,check if local and peer between 2 side.

ii. If path configure correct,add new aal2path

i. if PATH bandwidth<1.5M,change to actural

if (IRATHO.AttIncCS/ VS.RAB.AttEstabCS.Conv)>10%if VS.RAB.FailEstab.PS.DLIUBBand.Cong VS.RAB.FailEstab.PS.ULIUBBand.Cong

a)check NCP/CCP if congestion, expansion

b)check if configure match with phsical BW;optimize active factor

c)change user GBR

Page 64: Cssr Cdr Guideline v1.1

d)Expansion, PIC BSS

c)Else,expansion

b)Expansion

if VS.RAB.FailEstab.PS.DLIUBBand.Cong VS.RAB.FailEstab.PS.ULIUBBand.Cong

VS.RAB.FailEstPs.ULCE.Cong VS.RAB.FailEstPs.DLCE.Cong

a) if NodeB dynamic CE enable, try decrease GBR(SET USERGBR : UlGBR=D32, DlGBR=D32)b) else expand CE

VS.RAB.FailEstPs.Power.Cong a)Check if CELLALGOSWITCH: NBMCacAlgoSwitch=HSDPA_UU_ADCTRL-0&HSUPA_UU_ADCTRL-0&HSDPA_GBP_MEAS-0)

b)1) if ul congestion :MOD CELLCAC: UlTotalEqUserNum=140 or more2) if dl congestion :MOD CELLALGOSWITCH: NBMDlCacAlgoSelSwitch=ALGORITHM_THIRD)

VS.RAB.FailEstPs.Code.Cong a)SET MACHSPARA: DYNCODESW=OPEN;ADD CELLHSDPA: AllocCodeMode=Manual, HsPdschCodeNum=1

TOP小区告警核查(特别是传输告警)

RNC侧告警:参考日常核查SOP,如有异常,进行处理

Page 65: Cssr Cdr Guideline v1.1

如果传输没有问题 提单Check Iu interface Alarm

RNC Alarm

TOP小区告警核查(特别是传输告警)

NodeB侧告警(i. 小区不可用告警(例如FP失败导致的小区不可用),ii. 传输告警(例如闪断,丢包),iii. DSP或CPU告警,iv. 射频告警;):对比话统和告警(以小时为粒度),查看告警出现后是否RRC接入失败次数有上升,告警消失后(如果消失的话),RRC接入失败次数也下降,如果是,说明RRC接入失败跟异常告警可能有关联,要处理告警信息

(可选)检查Iub是否存在丢包 a) 对ATM传输,检测E1的误码率(参看文档)

b) 对IP传输,检测IP网络的丢包率(参看文档)

Check Iu-CS AAL2PATH or IPPATH configuration

Check Iu-CS if have packet Loss

Top cell Alarm Check ,transmission alarm NodeB Alarm:

i. Cell unavailable ii. Transmission Alarmiii. DSP or CPU alarm,alarm;

Check Iub AAL2PATH or IPPATH configuration

Page 66: Cssr Cdr Guideline v1.1

Check IuB if have packet Loss

Excalated

TOP cell Alarm Check RNC Alarm

Interference Check RTWP>-90dBm

i.ATM,Check BERii.IP: Check Packet Loss Rate

NodeB Alarm:i. Cell unavailable ii. Transmission Alarmiii. DSP or CPU alarm,iv. Clock alarm or RF alarm;

Page 67: Cssr Cdr Guideline v1.1

Action

Page 68: Cssr Cdr Guideline v1.1
Page 69: Cssr Cdr Guideline v1.1
Page 70: Cssr Cdr Guideline v1.1