cree engineering services testing laboratory (cestl...
TRANSCRIPT
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R009 Rev D This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was
produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0.
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 1 of 15
Report Number: PL10405-001A
Model: OSQ-HO-A-xx-5ME-40L-50K-UL
Date: 03/25/17
Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation
Report
Prepared For:
Chris Strom
Cree, Inc
9201 Washington Avenue
Racine, WI 53406
Prepared By: Approved By:
April Gressel, Photometric Technician Becky Kuebler, Manager Test Engineering
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 2 of 15
Product Information
Manufacturer Cree Inc Model Number (SKU) OSQ-HO-A-xx-5ME-40L-50K-UL Serial Number KL081J59994 LED Type XHP70
Product Description
Brown finned metal housing. Two LED boards each with 13 LEDs. Two white plastic optical carriers. One clear plastic lens below each LED. One black plastic uplight shield attached to each carrier.
Driver Information (Where Applicable)
PHILIPS XI220C105V210CNA1
Length Width Height
30” 22” 4”
Sample
The following sample was submitted for evaluation
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 3 of 15
Key Photometric Data Sphere Output Goniophotometer
Luminous Flux 31754.0 30955.8 lm
Efficacy 90.86 88.34 lm/W
Correlated Color Temperature (CCT) 4881 K
Color Rendering Index (CRI) 94
R9 73
Duv 0.000578
S/P Ratio* 2.06 Sphere Goniophotometer
Electrical Measurements 120V 277V 120V 277V
Input Wattage 349.50 344.3 351.03 343.76 W
Input Current 2.92 1.26 2.95 1.26 A
Input Voltage 119.98 277.09 119.05 277.06 V
Power Factor 0.998 .984 0.998 .983
Off-State Power 0 0 0 0 W
Total Harmonic Distortion (Voltage) 0.16 .10 0.13 0.11 %
Total Harmonic Distortion (Amperage) 5.45 12.70 5.48 12.67 %
Note: All photometric measurements taken at 120 VAC.
Luminous Intensity Distribution Goniophotometer
Max Candela 13103.7 Cd
Horizontal Angle of Max Candela 135 ˚
Vertical Angle of Max Candela 70 ˚
Key Test Parameters Sphere Output Goniophotometer
Stabilization Time 120 94 min
Total Operating Time (Stabilization + Test) 120 114 min
Ambient Temperature 24.5 24.1 ˚C
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 4 of 15
Chromaticity Coordinates
x y u v u’ v’ Duv
0.3486 0.3555 0.2123 0.3247 0.2123 0.4871 0.000578
Color Rendering Index Details
Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14
94 94 98 98 92 92 94 94 89 73 93 92 69 96 99
Chromaticity Diagram
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 5 of 15
Spectral Distribution
λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm
360 0.001105 530 0.434051 700 0.140299 370 0.001467 540 0.449234 710 0.108773 380 0.001177 550 0.458003 720 0.083298 390 0.001317 560 0.458594 730 0.062002 400 0.001778 570 0.454847 740 0.046395 410 0.005833 580 0.454081 750 0.035145 420 0.028645 590 0.454021 760 0.026297 430 0.099049 600 0.457441 770 0.019651 440 0.259405 610 0.460089 780 0.014668 450 0.649339 620 0.452546 790 0.010739 460 0.581246 630 0.436656 800 0.008087 470 0.404413 640 0.407618 810 0.006026 480 0.299112 650 0.367712 820 0.004820 490 0.306060 660 0.320761 830 0.003698 500 0.349690 670 0.269800 510 0.389059 680 0.222425 520 0.412577 690 0.178177
Dominant Wavelength 573 nm Peak Wavelength: 454 nm
Spectral Power Distribution (W/nm)
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 6 of 15
Zonal Lumen Summary **
Zone Lumens % of Total Zone Lumens % of Total 0-5 66.9 0.2% 90-95 0 0%
5-10 193.5 0.6% 95-100 0 0% 10-15 308.0 1.0% 100-105 0 0% 15-20 415.6 1.3% 105-110 0 0% 20-25 517.6 1.7% 110-115 0 0% 25-30 627.2 2.0% 115-120 0 0% 30-35 828.6 2.7% 120-125 0 0% 35-40 1,067.4 3.4% 125-130 0 0% 40-45 1,219.8 3.9% 130-135 0 0% 45-50 1,518.6 4.9% 135-140 0 0% 50-55 1,995.0 6.4% 140-145 0 0% 55-60 2,607.1 8.4% 145-150 0 0% 60-65 3,334.0 10.8% 150-155 0 0% 65-70 4,165.3 13.5% 155-160 0 0% 70-75 4,639.1 15.0% 160-165 0 0% 75-80 4,063.6 13.1% 165-170 0 0% 80-85 2,609.2 8.4% 170-175 0 0% 85-90 779.3 2.5% 175-180 0 0%
Total 30955.8 lm 100%
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 7 of 15
Candela Plot ** Illuminance Plot **
Roadway Utilization ** Roadway Summary ** Lumens % Lamp
Distribution Type VS Downward Street Side 15199.3 49.1% Downward House Side 15755.5 50.9% Downward Total 30954.8 100% Upward Street Side 0 0% Upward House Side 0 0% Upward Total 0 0% Total Lumens 30954.8 100%
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 8 of 15
Luminaire Classification System **
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 9 of 15
Candela Tabulations **
0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5
0 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825
2.5 2804 2795 2800 2804 2811 2816 2822 2825 2826 2827 2828 2829 2830 2831 2831
5 2774 2762 2769 2777 2784 2787 2790 2791 2790 2790 2789 2789 2789 2788 2788
7.5 2713 2697 2710 2722 2736 2741 2737 2735 2734 2732 2729 2726 2725 2724 2723
10 2634 2620 2638 2658 2677 2684 2677 2672 2669 2667 2663 2659 2657 2655 2654
12.5 2567 2558 2578 2601 2625 2636 2625 2618 2615 2612 2608 2605 2602 2600 2597
15 2516 2512 2533 2556 2587 2602 2583 2575 2572 2569 2566 2564 2561 2558 2555
17.5 2481 2478 2496 2517 2556 2576 2547 2536 2533 2531 2529 2527 2525 2523 2520
20 2452 2447 2464 2484 2534 2562 2522 2502 2498 2494 2493 2492 2490 2489 2486
22.5 2416 2406 2424 2457 2510 2545 2502 2480 2472 2464 2459 2454 2452 2451 2449
25 2369 2368 2392 2446 2493 2535 2490 2474 2463 2452 2442 2432 2430 2427 2424
27.5 2351 2363 2390 2442 2508 2548 2506 2482 2470 2459 2449 2438 2435 2431 2426
30 2362 2396 2443 2492 2574 2610 2571 2555 2549 2543 2535 2527 2523 2519 2505
32.5 2428 2572 2704 2751 2749 2800 2769 2803 2810 2818 2823 2827 2825 2823 2791
35 2657 2912 3120 3152 3006 3085 3064 3126 3144 3162 3166 3170 3171 3172 3120
37.5 2844 2991 3211 3198 3188 3331 3176 3210 3217 3224 3221 3218 3218 3218 3170
40 2806 2826 3030 3054 3220 3522 3172 3114 3104 3095 3082 3069 3056 3044 3011
42.5 2740 2735 2891 2982 3297 3805 3249 3099 3076 3053 3030 3007 2976 2945 2912
45 2765 2755 2897 3042 3490 4240 3428 3222 3184 3146 3120 3095 3051 3007 2965
47.5 2890 2890 3031 3220 3793 4844 3727 3472 3420 3368 3345 3322 3275 3228 3189
50 3072 3143 3283 3495 4170 5547 4125 3818 3758 3697 3672 3647 3607 3567 3534
52.5 3437 3508 3639 3906 4653 6328 4633 4280 4204 4128 4091 4054 4003 3952 3903
55 3899 3909 4045 4403 5311 7204 5269 4845 4730 4615 4539 4464 4396 4328 4272
57.5 4186 4272 4470 4956 6097 8182 6007 5466 5297 5128 5013 4899 4802 4705 4627
60 4412 4476 4867 5521 6985 9243 6813 6094 5867 5640 5487 5334 5191 5048 4936
62.5 4649 4728 5206 6155 8066 10422 7813 6830 6520 6210 5994 5778 5605 5432 5277
65 4952 5164 5725 6861 9106 11550 8836 7651 7269 6888 6626 6364 6169 5975 5805
67.5 5535 5782 6411 7612 10052 12400 9760 8418 8008 7597 7312 7027 6821 6615 6434
70 6264 6541 7101 8254 10751 12920 10433 9037 8607 8177 7877 7578 7373 7168 6995
72.5 7239 7262 7607 8608 10920 12777 10542 9248 8849 8449 8176 7902 7719 7536 7388
75 7471 7182 7559 8454 10515 12060 10144 8932 8582 8231 7988 7745 7554 7364 7207
77.5 6918 6510 6865 7690 9466 10792 9006 7903 7618 7334 7129 6924 6772 6620 6473
80 6031 5520 5916 6547 7914 8972 7396 6548 6342 6136 5959 5781 5705 5629 5504
82.5 4159 3672 4793 5256 6195 6936 5708 5179 5012 4845 4684 4523 4448 4372 4293
85 1863 1587 3279 3634 4398 4734 3895 3470 3341 3212 3063 2914 2822 2731 2658
87.5 620 452 1626 1703 2194 1607 1761 1477 1420 1364 1313 1261 1157 1052 976
90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 10 of 15
Candela Tabulations (Continued) **
80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180
0 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825 2825
2.5 2831 2832 2832 2832 2831 2832 2830 2825 2820 2812 2804 2795 2787 2783 2775
5 2787 2787 2787 2787 2787 2789 2789 2789 2786 2776 2763 2747 2735 2729 2710
7.5 2721 2721 2720 2720 2721 2724 2728 2733 2732 2720 2699 2676 2659 2650 2634
10 2652 2651 2649 2651 2652 2655 2663 2672 2674 2664 2639 2611 2592 2581 2573
12.5 2595 2593 2591 2593 2595 2600 2610 2617 2625 2621 2592 2564 2546 2535 2530
15 2551 2550 2548 2550 2551 2557 2567 2571 2589 2590 2555 2526 2509 2497 2495
17.5 2517 2515 2514 2515 2516 2521 2529 2533 2562 2567 2522 2487 2475 2462 2459
20 2484 2482 2479 2480 2482 2486 2492 2502 2545 2557 2503 2458 2439 2424 2422
22.5 2447 2444 2442 2443 2444 2449 2457 2483 2526 2546 2487 2445 2401 2387 2386
25 2422 2420 2418 2417 2416 2424 2437 2480 2523 2551 2492 2430 2378 2363 2367
27.5 2422 2417 2412 2412 2411 2424 2449 2494 2556 2591 2526 2441 2395 2372 2381
30 2491 2471 2451 2451 2452 2476 2542 2585 2645 2702 2598 2562 2517 2429 2438
32.5 2759 2683 2608 2597 2587 2681 2834 2891 2869 2976 2846 2937 2896 2660 2671
35 3068 2942 2816 2796 2775 2954 3192 3256 3185 3380 3215 3292 3267 2929 2899
37.5 3122 3011 2900 2886 2873 3014 3274 3334 3404 3763 3379 3345 3323 2997 2968
40 2978 2910 2841 2845 2849 2892 3157 3262 3550 4129 3464 3267 3196 2995 3023
42.5 2880 2837 2794 2819 2844 2850 3094 3280 3768 4587 3666 3362 3241 3093 3163
45 2924 2894 2863 2906 2950 2934 3195 3442 4078 5136 3966 3586 3415 3235 3351
47.5 3150 3121 3093 3138 3183 3168 3456 3722 4470 5752 4334 3884 3673 3486 3604
50 3501 3472 3443 3478 3513 3495 3792 4081 4905 6409 4773 4244 3979 3803 3968
52.5 3854 3832 3811 3871 3931 3891 4174 4530 5436 7172 5309 4643 4322 4158 4411
55 4215 4190 4165 4235 4305 4253 4561 5009 6114 8061 5968 5081 4668 4478 4599
57.5 4549 4508 4468 4507 4545 4535 4950 5536 6959 9076 6728 5590 5048 4683 4790
60 4825 4766 4707 4730 4754 4768 5285 6099 7908 10209 7601 6140 5362 4881 5014
62.5 5122 5053 4984 5005 5027 5034 5674 6711 8957 11334 8636 6723 5767 5241 5410
65 5635 5558 5482 5501 5520 5546 6253 7389 9988 12242 9625 7406 6294 5721 5837
67.5 6254 6179 6104 6118 6133 6160 6892 8074 10777 12890 10417 8090 6930 6269 6432
70 6822 6764 6705 6715 6725 6708 7411 8610 11148 13104 10850 8618 7580 6992 7224
72.5 7239 7228 7217 7236 7255 7159 7646 8720 10960 12558 10664 8672 7815 7460 7584
75 7050 7018 6987 7014 7041 6906 7324 8313 10201 11480 9905 8217 7412 7168 7140
77.5 6326 6310 6295 6306 6317 6130 6501 7393 8896 10034 8698 7302 6587 6310 6171
80 5379 5241 5103 5088 5073 5044 5526 6198 7113 8172 7204 6153 5614 5025 4465
82.5 4214 3757 3300 3232 3164 3298 4287 4765 5356 6098 5520 4919 4614 3307 2729
85 2584 2062 1540 1517 1494 1510 2690 2911 3448 3738 3912 3647 3504 1904 1613
87.5 900 683 466 473 481 444 1027 1073 1310 990 1816 1650 1726 778 449
90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 11 of 15
Candela Tabulations (Continued) **
0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5
92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 12 of 15
Candela Tabulations (Continued) **
80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180
92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 13 of 15
Integrating Sphere Equipment List
Description Manufacturer Model Serial Number
3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456
CCD Array Spectrometer Otsuka MC-9801 98010165
Programmable AC Source Chroma 61603 616030000761
Single Channel Power Analyzer Xitron 2801 28011110008
Aux Lamp Power Supply Labsphere LPS-100-0833 1002104538
Goniophotometer Equipment List
Description Manufacturer Model Serial Number
AC Power Source Adaptive FC210 2300229
AC Power Source Elgar CW1251 1126A06399
Type C Goniophotometer LSI / UL 6440T 6440TE0192T
Spectroradiometer Gooch & Housego 770VIS/NIR 11414155
Power Meter Yokogawa WT210 91L220953
Test Methods Used:
Title Description
ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004 Colorimetry
IES LM-58:1994 Spectroradiometric Measurements
IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used:
Equipment Description
3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number G141
Type C Goniophotometer Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Number 97A
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 14 of 15
Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.
The results contained in this report pertain only to the tested sample.
This report shall not be reproduced, except in full, without written approval of the CESTL.
* Items marked with a single asterisk are not covered by the NVLAP accreditation.
In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.
** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Goniophotometer”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an integrating sphere.
The goniophotometer information in the equipment list, report items marked with **, or results specifically identified as “Goniophotometer”, are the actual equipment used, and test results produced, by the subcontracted laboratory.
Additional Comments:
The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test.
Sphere Picture Goniophotometer Picture
NVLAP Lab Code 500077-0
Test Report Number: PL10405-001A CESTL-R017 Rev D
C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3
Page 15 of 15
Document Revision History:
Each subsequent revision of this report replaces the preceding report.
Date Rev DCN # Change Details By Approval
03/25/17 A DMS Origination A. Gressel B. Kuebler