cree engineering services testing laboratory (cestl...

12
NVLAP Lab Code 500077-0 Test Report Number: PL08677-001B CESTL-R009 Rev F This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that was produced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0. Cree, Inc | 4600 Silicon Drive | Durham, NC 27703 Page 1 of 12 Report Number: PL08677-001B Model: S-WR4-40L-40K-10V Date: 8/5/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jon Vollers Cree, Inc 4600 Silicon Drive Durham, NC 27703 Prepared By: Approved By: April Gressel, Photometric Technician Christopher McLaurin, Photometric Specialist

Upload: dinhngoc

Post on 11-May-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

This report contains data that are not covered by the NVLAP accreditation. This report also contains goniometric data that wasproduced under subcontract by Cree Durham Technology Center, NVLAP Lab Code 500070-0.

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 1 of 12

Report Number: PL08677-001B

Model: S-WR4-40L-40K-10V

Date: 8/5/2016

Cree Engineering Services Testing Laboratory

(CESTL) Photometric Testing and Evaluation

Report

Prepared For:

Jon Vollers

Cree, Inc

4600 Silicon Drive

Durham, NC 27703

Prepared By: Approved By:

April Gressel, Photometric Technician Christopher McLaurin, Photometric Specialist

Page 2: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 2 of 12

Product Information

Manufacturer Cree Inc

Model Number (SKU) S-WR4-40L-40K-10V

Serial Number PL08677-001

LED Type Lextar 3030

Product Description

4’ linear wrap light with a curved diffusion lens

Driver Information (Where Applicable)

ZR 40W Class 2

Length Width Height

48” 5” 3”

Sample

The following sample was submitted for evaluation

Page 3: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 3 of 12

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 4470.0 4348.0 lm

Efficacy 124.65 122.90 lm/W

Correlated Color Temperature (CCT) 3984 K

Color Rendering Index (CRI) 82

R9 7

Duv 0.001088

S/P Ratio* 1.67

Sphere Goniophotometer

Electrical Measurements 120V 120V

Input Wattage 35.86 35.83 W

Input Current 0.30 .30 A

Input Voltage 120.07 120.01 V

Power Factor 0.994 0.993

Off-State Power 0 0 W

Total Harmonic Distortion (Voltage) 0.05 .07 %

Total Harmonic Distortion (Amperage) 6.78 6.71 %

Luminous Intensity Distribution Goniophotometer

Max Candela 1342.5 Cd

Horizontal Angle of Max Candela 247.5 ˚

Vertical Angle of Max Candela 2.5 ˚

Zonal Lumens (0˚ – 30˚) 1034.6 (23.8) lm (%)

Zonal Lumens (0˚ – 40˚) 1700.7 (39.1) lm (%)

Zonal Lumens (0˚ – 60˚) 3048.4 (70.1) lm (%)

Zonal Lumens (60˚ – 90˚) 1095.7 (25.2) lm (%)

Color Angular Uniformity NA

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 58 42 min

Total Operating Time (Stabilization + Test) 58 62 min

Ambient Temperature 25.4 24.7 ˚C

Page 4: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 4 of 12

Chromaticity Coordinates

x y u v u’ v’ Duv

0.3818 0.3799 0.2247 0.3355 0.2247 0.5032 0.001088

Color Rendering Index Details

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

82 81 88 94 82 81 84 86 64 7 72 81 62 82 97

Chromaticity Diagram

Page 5: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 5 of 12

Spectral Distribution

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.000222 530 0.055236 700 0.009961

370 0.000214 540 0.058694 710 0.007336

380 0.000149 550 0.062435 720 0.005412

390 0.000166 560 0.066464 730 0.003938

400 0.000149 570 0.070964 740 0.002868

410 0.000544 580 0.074481 750 0.002061

420 0.002824 590 0.076943 760 0.001559

430 0.011859 600 0.076994 770 0.001150

440 0.044289 610 0.073057 780 0.000871

450 0.084378 620 0.066523 790 0.000672

460 0.045849 630 0.057991 800 0.000491

470 0.025245 640 0.048945 810 0.000380

480 0.021620 650 0.039854 820 0.000326

490 0.027125 660 0.031592 830 0.000290

500 0.037532 670 0.023971

510 0.045690 680 0.017987

520 0.051545 690 0.013495

Dominant Wavelength 578 nm

Peak Wavelength: 448 nm

Spectral Power Distribution (W/nm)

Page 6: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 6 of 12

Zonal Lumen Summary **

Zone Lumens % of Total Zone Lumens % of Total

0-5 31.6 0.7% 90-95 60.5 1.4%

5-10 93.9 2.2% 95-100 43.0 1%

10-15 153.1 3.5% 100-105 30.2 0.7%

15-20 207.3 4.8% 105-110 21.1 0.5%

20-25 254.7 5.9% 110-115 14.7 0.3%

25-30 293.9 6.8% 115-120 10.3 0.2%

30-35 323.5 7.4% 120-125 7.3 0.2%

35-40 342.6 7.9% 125-130 5.3 0.1%

40-45 350.8 8.1% 130-135 3.9 0.1%

45-50 348.4 8.0% 135-140 2.9 0.1%

50-55 335.5 7.7% 140-145 2.0 0%

55-60 313.0 7.2% 145-150 1.2 0%

60-65 282.3 6.5% 150-155 0.8 0%

65-70 244.6 5.6% 155-160 0.5 0%

70-75 202.7 4.7% 160-165 0.3 0%

75-80 160.1 3.7% 165-170 0.1 0%

80-85 120.1 2.8% 170-175 0.0 0%

85-90 85.8 2.0% 175-180 0.0 0%

Total 4348.0 lm 100%

Spacing Criteria **

Spacing Criterion (0 - 180) 1.24

Spacing Criterion (90 - 270) 1.28

Spacing Criterion (Diagonal) 1.40

Page 7: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

Test Report Number:

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7

NVLAP Lab Code 500077

Test Report Number: PL08677-001B

| 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3

Candela Plots **

Isofootcandle Plot **

NVLAP Lab Code 500077-0

CESTL-R009 Rev F

Page 7 of 12

Page 8: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 8 of 12

Candela Tabulations **

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324 1324

2.5 1297 1319 1326 1339 1327 1339 1326 1319 1297 1323 1328 1342 1331 1342 1328 1323 1297

5 1293 1313 1319 1333 1321 1333 1319 1313 1293 1320 1326 1340 1330 1340 1326 1320 1293

7.5 1285 1305 1310 1323 1311 1323 1310 1305 1285 1314 1322 1336 1325 1336 1322 1314 1285

10 1275 1294 1298 1311 1300 1311 1298 1294 1275 1304 1314 1330 1317 1330 1314 1304 1275

12.5 1262 1280 1284 1297 1286 1297 1284 1280 1262 1292 1304 1320 1308 1320 1304 1292 1262

15 1245 1264 1268 1280 1267 1280 1268 1264 1245 1277 1290 1308 1298 1308 1290 1277 1245

17.5 1226 1244 1249 1261 1248 1261 1249 1244 1226 1260 1273 1293 1285 1293 1273 1260 1226

20 1204 1223 1228 1239 1228 1239 1228 1223 1204 1239 1254 1276 1268 1276 1254 1239 1204

22.5 1180 1199 1204 1215 1204 1215 1204 1199 1180 1215 1232 1256 1248 1256 1232 1215 1180

25 1153 1172 1178 1190 1179 1190 1178 1172 1153 1189 1208 1232 1226 1232 1208 1189 1153

27.5 1124 1143 1149 1162 1153 1162 1149 1143 1124 1160 1181 1206 1200 1206 1181 1160 1124

30 1093 1111 1118 1133 1124 1133 1118 1111 1093 1129 1152 1178 1172 1178 1152 1129 1093

32.5 1059 1076 1085 1101 1093 1101 1085 1076 1059 1095 1119 1147 1142 1147 1119 1095 1059

35 1024 1040 1050 1066 1058 1066 1050 1040 1024 1059 1085 1114 1110 1114 1085 1059 1024

37.5 985 1002 1013 1029 1023 1029 1013 1002 985 1020 1048 1078 1075 1078 1048 1020 985

40 946 961 974 991 985 991 974 961 946 980 1009 1039 1038 1039 1009 980 946

42.5 905 919 933 950 946 950 933 919 905 937 969 1000 1000 1000 969 937 905

45 864 876 891 909 906 909 891 876 864 894 927 958 961 958 927 894 864

47.5 821 830 848 866 866 866 848 830 821 848 883 916 920 916 883 848 821

50 776 783 803 823 823 823 803 783 776 802 838 872 878 872 838 802 776

52.5 729 735 756 778 780 778 756 735 729 754 791 827 835 827 791 754 729

55 680 686 708 732 736 732 708 686 680 704 744 782 792 782 744 704 680

57.5 630 636 660 687 693 687 660 636 630 654 696 736 748 736 696 654 630

60 579 585 612 643 651 643 612 585 579 603 647 690 704 690 647 603 579

62.5 527 534 564 598 608 598 564 534 527 551 598 644 660 644 598 551 527

65 473 481 516 554 566 554 516 481 473 497 549 597 615 597 549 497 473

67.5 418 428 469 510 523 510 469 428 418 443 500 551 570 551 500 443 418

70 362 375 422 466 482 466 422 375 362 390 452 506 527 506 452 390 362

72.5 306 324 378 425 442 425 378 324 306 338 406 462 485 462 406 338 306

75 251 274 335 385 404 385 335 274 251 287 360 420 443 420 360 287 251

77.5 199 228 295 348 367 348 295 228 199 240 318 380 403 380 318 240 199

80 149 184 256 312 333 312 256 184 149 195 277 340 364 340 277 195 149

82.5 104 146 221 279 300 279 221 146 104 155 239 304 328 304 239 155 104

85 63 112 189 247 269 247 189 112 63 120 205 270 295 270 205 120 63

87.5 27 84 162 219 240 219 162 84 27 89 174 238 263 238 174 89 27

90 1 62 136 192 214 192 136 62 1 65 147 209 233 209 147 65 1

Page 9: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 9 of 12

Candela Tabulations (Continued) **

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

92.5 0 44 115 169 189 169 115 44 0 47 123 183 206 183 123 47 0

95 0 32 96 147 167 147 96 32 0 33 102 159 181 159 102 33 0

97.5 0 23 80 128 147 128 80 23 0 23 85 137 158 137 85 23 0

100 0 16 66 111 128 111 66 16 0 16 69 118 138 118 69 16 0

102.5 0 12 55 96 112 96 55 12 0 12 56 101 119 101 56 12 0

105 0 9 46 82 97 82 46 9 0 9 46 85 102 85 46 9 0

107.5 0 8 38 70 84 70 38 8 0 8 38 72 88 72 38 8 0

110 0 7 31 60 72 60 31 7 0 6 32 62 75 62 32 6 0

112.5 0 6 26 51 62 51 26 6 0 6 26 52 64 52 26 6 0

115 0 5 22 44 53 44 22 5 0 5 22 44 55 44 22 5 0

117.5 0 4 19 38 46 38 19 4 0 4 19 38 47 38 19 4 0

120 0 4 17 32 39 32 17 4 0 4 17 32 40 32 17 4 0

122.5 0 3 15 28 34 28 15 3 0 3 14 28 34 28 14 3 0

125 0 2 13 24 29 24 13 2 0 2 13 24 30 24 13 2 0

127.5 0 2 12 22 25 22 12 2 0 2 12 22 26 22 12 2 0

130 0 2 11 19 22 19 11 2 0 2 11 19 23 19 11 2 0

132.5 0 2 10 18 20 18 10 2 0 1 10 17 20 17 10 1 0

135 0 1 9 16 18 16 9 1 0 1 8 16 18 16 8 1 0

137.5 0 1 7 15 17 15 7 1 0 1 6 14 17 14 6 1 0

140 0 1 5 13 16 13 5 1 0 1 5 13 15 13 5 1 0

142.5 0 1 5 12 14 12 5 1 0 1 5 11 14 11 5 1 0

145 0 1 4 10 13 10 4 1 0 1 4 8 12 8 4 1 0

147.5 0 1 4 7 10 7 4 1 0 1 4 6 8 6 4 1 0

150 0 1 4 7 8 7 4 1 0 1 3 6 7 6 3 1 0

152.5 0 1 3 5 8 5 3 1 0 1 3 5 7 5 3 1 0

155 0 1 3 4 6 4 3 1 0 0 3 4 6 4 3 0 0

157.5 0 1 3 4 5 4 3 1 0 0 3 3 5 3 3 0 0

160 0 1 2 4 5 4 2 1 0 0 2 3 4 3 2 0 0

162.5 0 1 2 3 4 3 2 1 0 0 2 2 4 2 2 0 0

165 0 1 2 2 3 2 2 1 0 0 1 2 3 2 1 0 0

167.5 0 0 1 1 2 1 1 0 0 0 1 1 2 1 1 0 0

170 0 0 1 1 2 1 1 0 0 0 1 1 1 1 1 0 0

172.5 0 0 0 1 1 1 0 0 0 0 0 1 1 1 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 10: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 10 of 12

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456

CCD Array Spectrometer Otsuka MC-9801 98010165

Programmable AC Source Chroma 61603 616030000761

Single Channel Power Analyzer Xitron 2801 28011110008

Aux Lamp Power Supply Labsphere LPS-100-0833 1002104538

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Adaptive FC210 2300229

AC Power Source Elgar CW1251 1126A06399

Type C Goniophotometer LSI / UL 6440T 6440TE0192T

Spectroradiometer Gooch & Housego 770VIS/NIR 11414155

Power Meter Yokogawa WT210 91L220953

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number G141

Type C Goniophotometer Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Number 97A

Page 11: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 11 of 12

Disclaimers:

This report must not be used by the customer to claim product certification, approval or endorsement byNVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the CESTL.

* Items marked with a single asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as

“Goniophotometer”, were performed by the subcontracted laboratory identified in the footer on the first page of

this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an

integrating sphere.

The goniophotometer information in the equipment list, report items marked with **, or results specifically

identified as “Goniophotometer”, are the actual equipment used, and test results produced, by the

subcontracted laboratory.

Additional Comments: This luminaire was tested in the base up orientation.

Sphere Picture Goniophotometer Picture

Page 12: Cree Engineering Services Testing Laboratory (CESTL ...creecanada.com/wp-content/uploads/2016/10/S-WR4-40L-40K-10V_PL... · 5-10 93.9 2.2% 95-100 43 ... 5 1293 1313 1319 1333 1321

NVLAP Lab Code 500077-0

Test Report Number: PL08677-001B CESTL-R009 Rev F

C r e e , I n c | 4 6 0 0 S i l i c o n D r i v e | D u r h a m , N C 2 7 7 0 3 Page 12 of 12

Document Revision History:

Each subsequent revision of this report replaces the preceding report.

Date Rev DCN # Change at the time of this test By Approval

8/5/16 A DMS Origination A. Gressel C. McLaurin

8/23/16 B DMS Updated Part Number A. Gressel C. McLaurin