Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources
![Page 2: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/2.jpg)
Objective of Stand-Alone Systems:A stand-alone power system (SAPS), also known as remote area
power supply (RAPS), is an off-the-grid electricity system for
locations that are not fitted with an electricity distribution system
There are several types of wind energy systems.There are stand-alone
systems which provide reliable power solely from the wind. A stand-
alone system may have a method for storing energy when wind
conditions are not good. Usually, batteries are used for storage.
These are applicable for micro systems(100watts or less) and can be
used for remote area lighting, portable and emergency lighting etc.
![Page 3: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/3.jpg)
Wind Energy Systems
![Page 4: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/4.jpg)
How much Energy is in Wind?
A wind energy system usually needs an
average annual wind speed of atleast
15km/hr.
Wind speed is measured by an instrument
called an anemometer which turns faster
as the wind blows harder on it. A data
logger can be used to record
instantaneous observations of wind
speed, or to store a long term record for
later analysis.
![Page 5: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/5.jpg)
Stand-Alone Wind Turbine Configuration
![Page 6: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/6.jpg)
Control Structure for Boost Converter
![Page 7: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/7.jpg)
MPPT CONTROL BLOCK
![Page 8: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/8.jpg)
STORAGE SYSTEM CONFIGURATION
![Page 9: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/9.jpg)
Advantages
A simple control strategy for generator side converter to extract maximum power is implemented using simulation software.
The controller is capable of maximizing output of variable speed wind turbine under fluctuating wind.
Controller can regulate the load voltage and frequency at constant or under varying load conditions.
Regulation of output is done without battery overcharging.So power can be effectively used.This contributes battery life extension and reliability.
![Page 10: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/10.jpg)
APPLICATIONS
These are useful for Portable system for lighting and
communication systems. Remote area lighting. Educational programs and displays. Electric fences.
![Page 11: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/11.jpg)
SIMULATION DIAGRAM FOR CONTROL STRUCTURE FOR SINGLE-PHASE STAND-ALONE WIND-BASED ENERGY SOURCES :
![Page 12: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/12.jpg)
SIMULATION RESULT WERE CARRIED BY:
1. variation of the wind speed, while the load is constant(two case studies).
Case 1) Decreasing variation of the wind speed, while the load is constant (P = 1 kW).
Case 2) Random wind speed variation with variable load.
2. load switching, with a fixed wind speed (two case studies).
Case 1) 2-kW load switching at 9 m/s
Case 2) 1-kW load switching at 0 m/s.
![Page 13: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/13.jpg)
CASE 1A) DECREASING VARIATION OF THE WIND SPEED, WHILE THE LOAD IS CONSTANT (P = 1 KW):
![Page 14: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/14.jpg)
CASE 2A) RANDOM WIND SPEED VARIATION WITH VARIABLE LOAD:
![Page 15: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/15.jpg)
CASE 1) 2-KW LOAD SWITCHING AT 9 M/S:
TIME(S)
![Page 16: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/16.jpg)
CASE 2B) 1-KW LOAD SWITCHING AT 0 M/S:
![Page 17: Control Structure for Single-Phase Stand -Alone Wind Based Energy Sources](https://reader033.vdocuments.us/reader033/viewer/2022061222/54bf9b6f4a7959d1158b461e/html5/thumbnails/17.jpg)
Thank you ..!!