Learning objective
• At the end of this lesson student should be able to:
–Measure physical quantities using appropriate instrument
– Explain accuracy and consistency
– Explain sensitivity
![Page 2: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/2.jpg)
Differentiate the distribution of gunshot below
Figure (a) Figure (b)
![Page 3: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/3.jpg)
ExplanationFigure (a)• Shots are closer to the target but scattered
from each other.• In other word, we can say all shot are
accurateFigure(b)• All shots are close to each other but far from
the target• In other word, we can say that all shots are
consistent
![Page 4: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/4.jpg)
What exactly means of consistency and accuracy???
![Page 5: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/5.jpg)
Introduction• Every measurement of a physical
quantity is an estimation only.
• No measurement is exactly accurate and consistent
• For example, 500 g of rice bought from a retail shop maybe 500.1 g or 499.9 g
![Page 6: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/6.jpg)
Consistency• If all the reading are the same or if the
variations are small, then the measurements are consistent
• Consistency of the measuring instrument is the ability of the instrument to produce reading that are consistent with little or no variations.
• Precise electronic measuring instruments such as the electronic balance usually produce consistent reading.
![Page 7: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/7.jpg)
Electronics balances
![Page 8: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/8.jpg)
Accuracy • The accuracy of measuring instrument is the
ability of the instrument to give measurements of a physical quantity which are close to the actual value.
• How to increase accuracy during take a reading? To increase accuracy during take a reading is take a reading many time (at least 3 times)
![Page 9: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/9.jpg)
According to the picture beside, interpret the distribution of gun shots.
• From the picture above we can say that the distribution of gun shots is accurate and consistent.
• This because all gun shots closest each other and closest to the target.
![Page 10: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/10.jpg)
Which of the following picture show us not accuracy but consistent?
BA
C D
![Page 11: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/11.jpg)
Which of the following picture show usaccuracy and consistent?
A B
C D
![Page 12: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/12.jpg)
Which of the following picture show us accuracy but not consistent?
A B
C D
![Page 13: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/13.jpg)
Example :• The actual height of the table is 56.2cm.
Two students, Ahmad and Bakri measure the height of the table and obtain the following data:
Ahmad (x)
56.3cm 56.2cm 56.1cm 56.4cm
Bakri(.)
57.0cm 57.0cm 57.1cm 57.1cm
![Page 14: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/14.jpg)
Solution
For Ahmad,
• His reading are considered accurate because they are very close to the actual reading
• His reading are considered not consistent because there are variations between the readings
For Bakri,
• His reading are considered inaccurate because they are far from the actual reading
• His readings are considered more consistent because they are concentrated on two values only
![Page 15: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/15.jpg)
1. If a group of students from your class leave for Japan by plane, how are the readings on their watches when they arrive in Japan?
A. Accurate but not consistentB. Consistent but not accurateC. Not consistent and not accurateD. Accurate and consistent
Answer: B
Quiz
![Page 16: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/16.jpg)
![Page 17: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/17.jpg)
Screw clamp to ensure that reading does not change while the scale is being read
Part of Vernier Callipers with their functions
![Page 18: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/18.jpg)
Method of Reading Vernier Calipers
![Page 19: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/19.jpg)
1. Determine the reading on the main scale, which is the value on the main scale just before the zero mark on the Vernier scale
The reading on main scale = 2.3cm
![Page 20: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/20.jpg)
2. Determine the reading on the Vernier scale, which is the marking on the Vernier scale which coincides with a marking on the main scale.
Vernier scale reading = 0.4 mm= 0.04 cm
![Page 21: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/21.jpg)
3. The total reading is obtained by adding the reading on the main scale with the reading on the Vernier scale.
![Page 22: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/22.jpg)
Will a measurement taken using this Verniercalipers be accurate? Why?
![Page 23: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/23.jpg)
• No, because this Vernier calipers has zero error. The ‘0’ mark on the main scale is not in line with the ‘0’ mark on the vernier scale when jaws of the vernier calipers is closed
![Page 24: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/24.jpg)
Zero Error on the Vernier Calipers
• There are two type of zero error on the Verniercalipers :
– Positive Zero Error
– Negative Zero Error
![Page 25: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/25.jpg)
Positive zero error
![Page 26: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/26.jpg)
Negative zero error In case you get the negative zero error, the value you obtain from Verniercaliper must be subtract with 0.1
![Page 27: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/27.jpg)
Micrometer screw Gauge
![Page 28: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/28.jpg)
How reading Micrometer Screw Gauge
Main scale ade dua scale:• Atas : yg mane setiap scale ni bermula dgn
0,1,2………• Bawah: yg bwh pula setiap satu bernilai 0.5
0.5
1
![Page 29: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/29.jpg)
• Semasa mengambil bacaan di ‘main scale’ pastikan scale ygkat bawah tu nampak atau tidak. Klau nampak, nilai yg katbawah kena tmbh dgn nilai yg kat atas.
• So, skrg bacaan di ‘main scale’ ialah 1.5
![Page 30: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/30.jpg)
• Then take a reading on thimble scale. Bacaan yg kitaambil adalah line on thimble scale yang coinside dgngaris tengah on the main scale.
• Berdsarkn gmbr diatas, 37 adalah garis yg coinsides…• Then, 37 X 0.01 = 0.37 , ini kerana setiap scale line
bernilai O.O1 mm
![Page 31: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/31.jpg)
• Reading on main scale + Reading on thimble scale
• 1.5 + 0.37 = 1.87 mm
![Page 32: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/32.jpg)
Positive zero error
If ‘0’ mark on main scale is locate above than ‘0’ mark on thimble scale, you will get positive zero error
![Page 33: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/33.jpg)
Negative zero errorIf ‘0’ mark on main scale is locate below than ‘0’ mark on thimble scale, you will get negative zero error
![Page 34: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/34.jpg)
1. Students measure the same book. But why they get different reading?• Because use the different type of instruments.
2. Which instruments is sensitive? Why?• Micrometer screw gauge because can read up
to 3 decimal place.
![Page 35: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/35.jpg)
Question:
![Page 36: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/36.jpg)
Question:
![Page 37: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/37.jpg)
Question:
![Page 38: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/38.jpg)
Answer:
![Page 39: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/39.jpg)
Question:
![Page 40: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/40.jpg)
Answer:
![Page 41: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/41.jpg)
Question:
![Page 42: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/42.jpg)
Answer:
![Page 43: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/43.jpg)
Question:
![Page 44: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/44.jpg)
Answer:
![Page 45: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/45.jpg)
Question:
![Page 46: Consistency, Accuracy and Sensitivity](https://reader033.vdocuments.us/reader033/viewer/2022042501/546a7601b4af9f86648b4764/html5/thumbnails/46.jpg)
Answers: