Components
Tower
Water Vacuum Supply Center
Air / Water Flow
Water / Descale Inlet
V1-Water inlet valve • Water inlet to unit V13-Descale • Only used for descale Both protected by
check valves
Water Pump
M1-Water Pump • Set at 90 PSI at the factory. • Adjustments may be
required during calibrations.
Flow Meter
FM-Flow Meter • Measures the volume of water
flowing through the unit
Thermoblock 1
TB1-Thermoblock 1-cold water • Heats the water to 45°C (113°F) • NTC Probe monitors the
temperature • Hi-limit trips at 75°C (167°F)
Thermoblock 2 & 3
TB2-Thermoblock 2 & TB3-Thermoblock 3-hot water • Heat the water to 120°C (248°F) • NTC Probe monitors the
temperature • Hi-limits trip at 150°C (302°F)
Proportional / Mixing Valve
V5-Mixing Valve • Regulates the flow of cold
water
Brewing Valve
V11-Brewing valve • Activates during the brew
cycle
Safety Overpressure Valve
UV1-Safety Valve • Set at 12 bar
Air Sanitizing Valve
V2-Air Sanitizing Valve • “Clean in Place” Cycle • “Descale” Cycle
Overpressure Relief Valve
UV3-Overpressure Relief Valve • Opens at 3 bar • Prevents steam in the lines
Flow Direction
Overpressure Valve
UV2-Overpressure Relief Valve • Opens at 3 bar • Prevents steam in the lines
Flow Direction
Temperature Sensor
T-mix-Temperature Sensor • Measures the temperature of
the combined cold and hot water
Fill Valve
V3-Fill Valve • Energized to fill brew
chamber • Located on the top of the
tower
Rinse Valve
V4-Rinse Valve • Energized to rinse brew
chamber • Located on the top of the
tower
Flow Regulator-Water
FR1-Flow Regulator • Located on the top of the
tower • **Currently not being used**
Brew Chamber
BC-Brew Chamber • Water and ingredients mix • Vacuum and purge occur
Flow Regulator-Vacuum Leak
FR2-Flow Regulator • Regulates the volume of
air entering the unit.
FR2 Flow Regulator
PS Pressure Sensor
V6 Atmosphere Valve
BC Brew chamber
M2 Vacuum Pump
Atmosphere
Pressure Sensor
PS-Pressure Sensor • Measures the air pressure in
the vacuum and purge lines
FR2 Flow Regulator
PS Pressure Sensor
V6 Atmosphere Valve
BC Brew chamber
M2 Vacuum Pump
Atmosphere
Atmosphere Valve
V6-Atmosphere Valve • Allows air to escape brew
chamber • Energized for vacuum and purge • Located on the top of the tower
FR2 Flow Regulator
PS Pressure Sensor
V6 Atmosphere Valve
BC Brew chamber
M2 Vacuum Pump
Atmosphere
Water Separator
WS-Air-Water Separator • Prevents water from
reaching the vacuum pump
Blowout Valve
V8-Blowout Valve • Energized to clear and drain
the Air-water separator
Vacuum Valve
V10-Vacuum valve • Energized to create vacuum
Vacuum Pump
M2-Vacuum Pump • Used for creating a vacuum • Used for purging brew
chamber • Used for flushing WS & V8
Flush Valve
V9-Flush Valve • Energized to flush brew
chamber
Purge Valve
Purge Valve • Located on the brew handle • Opens at 3 PSI
Components