clean air catalog

94
CLEAN AIR ENGINEERING 2009 CATALOG cleanair.com 1.800.223.3977 A ir Pollution Sampling Equipment For Environmental Professionals Worldwide

Upload: ryan-redel

Post on 15-Nov-2014

114 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Clean Air Catalog

C L E A N A I R E N G I N E E R I N G

2 0 0 9 C ATA L O Gcleanair.com

1.800.223.3977

Air Pollution Sampling Equipment For Environmental Professionals

Worldwide

®

Page 2: Clean Air Catalog

OUR GUARANTEECleanAir Express products are guaranteed to give you 100% satisfaction in every way. Return any CleanAir Manufactured products to us at any time if it proves otherwise. We will repair it, re-place it, or refund the original purchase price. We do not want you to own any Clean Air Express product unless you are completely satisfi ed.

TERMS & CONDITIONSPrices and TermsOur prices are subject to change without notice. The price in ef-fect when we receive your order will apply. All prices are F.O.B. Palatine, Illinois. We will be pleased to furnish quotations by phone, fax, e-mail or mail. Terms of payment are Net 30 days with established credit, or by Visa/Master Card at time of order. Invoices over 30 days past due are subject to a 1.5% fi nance charge per month.Confi rming OrdersPlease make sure that all confi rming orders are clearly marked to avoid duplicate orders.Shipments and DeliveryUnless otherwise instructed, shipments are made as soon as possible after receipt of order by the method of transportation, which in our judgment will be most satisfactory. Freight charges are prepaid and added to the invoice. The right is reserved to make partial shipments where delays beyond our control may delay a portion of the order.Export Processing and PricingThe prices in the Domestic price list are for delivery in the USA. Orders for delivery to other countries will be based on Export price list.Returned ItemsAuthorization must be obtained from us before returning any goods. When requesting return authorization, please advise reason for return, date of purchase, your P.O. number and our invoice number. Equipment produced to special specifi cations is not returnable. All returns must be shipped freight prepaid at the purchase’s expense.WarrantyClean Air Engineering warrants products to be free from defects and workmanship for a period of one year after delivery date. The sole and exclusive remedy for defective goods shall be re-pair or replacement of defective parts or payment price of the goods for which damages are claimed, at Clean Air Engineer-ing’s option.Design ChangesDesign changes are made from time to time. Some items may differ slightly from catalog illustrations or descriptions. Changes are made in the interest of better performance and quicker de-livery.Acceptance of Terms and ConditionsClean Air Engineering sells products only under the foregoing terms and conditions and will not be bound by terms or condi-tions stated by any purchaser in any offer, acceptance, or other contractual document. Placing an order or accepting delivery of products constitutes acceptance of terms and conditions.

OUR FIELD EMERGENCY SERVICECleanAir Express will ship, overnight and at our expense, any CleanAir Express component to complete your testing in the event of equipment failure. We will do this for any location in the U.S. via Fed Ex Priority Overnight ®. In addition we will also provide a replacement for any competing Method 5 equipment that is compatible with Clean Air components. This service is provided free of charge to any past or future Clean Air customers. We only request that you return the equipment as soon as possible with a brief explanation of the problem you encountered and any ideas you have on how it can be prevented.

Page 3: Clean Air Catalog

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

AIR POLLUTION SAMPLING EQUIPMENT

Clean Air Engineering Headquarters500 West Wood StreetPalatine, Illinois 60067Tel: 800-627-0033 847-991-3300Fax: 847-991-3385

Clean Air Engineering Express212 Woodwork Lane

Palatine, Illinois 60067Tel: 800-223-3977Fax: 847-991-8924

• Calibration Services • Technical Services• Engineering and Custom Fabrication

Services• Repair Services

Contact UsFor Your Convenience we Accept:

Page 4: Clean Air Catalog

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

Table of ContentsSOURCE SAMPLING EQUIPMENT

AIR POLLUTION SAMPLING EQUIPMENT

SOURCE SAMPLING EQUIPMENT CONTINUEDPage

Method 2 ................................................................ 1-3 Air Velocity Kit ..................................................... 1-3 Pitot Assemblies .................................................. 1-3 Replacement Pitot for Pitot Assemblies .............. 1-3 Traverse Umbilical Cable .................................... 1-3 Solid Thermocouples .......................................... 1-4Method 3 ................................................................ 1-5 Flue Gas Analyzer ............................................... 1-5 Tedlar Bags ......................................................... 1-6 Sample Pump ..................................................... 1-6Method 5 ................................................................ 1-7 Method 5 Sampling Train .................................... 1-7 Cateco Method 5 Sampling Train ........................ 1-9 Isokinetic Control Console ................................ 1-13 Control Console Shipping Case ........................ 1-15 Critical Orifi ce Set .............................................. 1-15 Impinger Outlet .................................................. 1-15 TI 86 Programmed Calculator ........................... 1-16 Replacement Dry Gas Meter ............................. 1-16 Calibration Dry Gas Meter ................................. 1-16 Sample Unit Oven Compartment ...................... 1-17 Cateco Heated Filter Unit ................................. 1-17 Modular Sample Unit ........................................ 1-18 Impinger Compartments .................................... 1-18 Heated Sample Probe ...................................... 1-19 Water-Cooled Sampling Probe ......................... 1-21 Heated Probe Liners ......................................... 1-23 Unheated Probe Liners ..................................... 1-24 Stainless Steel Ball Joint and Socket ................ 1-24 Replacement Pitot for Probe Assemblies .......... 1-25 Method 5 Probe Rewrap Kits ............................ 1-25 Stainless Steel Port Adapter Seal Assembly ..... 1-25 Sample Recovery Kit ......................................... 1-26 Probe Rod Kits and Probe Wash Bottles .......... 1-26 Sample Containers ............................................ 1-26 Method 5 Umbilical Cable ................................. 1-27 Isokinetic Sampling Nozzles ............................. 1-27

PageMethod 5 ................................................................ 1-7 Isokinetic Sampling Nozzles Accessories ......... 1-28 Method 5 Ball Joint (O-ring) Glassware Sets .. 1-29 Glassware Shipping Case ................................ 1-29 Individual Ball Joint Glassware and Clamps ..... 1-31 Tefl on® Impingers/Connectors/Filter Holders .... 1-31 Filter Holders, Frits and Clamp Rings ............... 1-32 Tared Filter Media ............................................. 1-33 Filters - Glass, Quartz and Tefl on® .................... 1-34Method 6 .............................................................. 1-35 Method 6 / Vost Control Console ...................... 1-35 Vost Control Console Shipping Case ................ 1-35 Method 6 Midget Sample Unit ........................... 1-36 Method 6 Umbilical Cable ................................. 1-36 Method 6 Individual Glassware ......................... 1-37 Method 6 Glassware Accessories ..................... 1-37 Method 6 Impinger Set ...................................... 1-38 Method 6 Heated Sampling Probe .................... 1-38Method 8A & SO3 ................................................. 1-39 8A & SO3 Controlled Condensation System ..... 1-39 8A & SO3 Probe ................................................ 1-41 8A & SO3 Glassware ......................................... 1-42Method 17 ............................................................ 1-43 Method 17 Probes ............................................. 1-43 Method 17 Umbilical Cables ............................. 1-43 Nozzles, Filter Holders & Associated Items ...... 1-43 Method 17 Train ................................................ 1-44Method 23 ............................................................ 1-45 Method 23 Sampling Train ................................ 1-45Method 29 ............................................................ 1-47 Method 29 Sampling Train ................................ 1-47Method 30B .......................................................... 1-49 Method 30B Control Console ............................ 1-49 Method 30B Gas Conditioner ............................ 1-51 Method 30B Probe ............................................ 1-51Method 201A ........................................................ 1-54 PM10 Cyclone Package .................................... 1-54

Page 5: Clean Air Catalog

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

Table of Contents

AIR POLLUTION SAMPLING EQUIPMENT

CEM EQUIPMENT PARTS & ACCESSORIES

PORTABLE ANALYZERS

PageNOX Analyzers ...................................................... 2-3 ECO Physics NOX Analyzer................................. 2-3CEM Probes .......................................................... 2-4 JCT Heated Filter Probe ..................................... 2-4 CEM Heated Filter Probe .................................... 2-5 Heated CEM Probes ........................................... 2-6CEM Equipment ................................................... 2-7 Cateco CEM Heated Filter Unit ........................... 2-7 Large Cateco CEM Heated Filter Unit ................ 2-8RATA & CEM Equipment ...................................... 2-8 CEM Heated 3 Point Probe ................................. 2-8 Heated Sample Line ........................................... 2-9Temperature Controllers ..................................... 2-10 Universal Temperature Controller ....................... 2-10 Multiple Zone Temperature Controller ................. 2-10 Rack Mount Temperature Controller ................... 2-10Sample Gas Conditioners ................................. 2-11 MAK 10 Gas Conditioner .................................. 2-11 SGC4000 Gas Conditioner ............................... 2-12 Stainless Steel Coil Condenser ........................ 2-12CEM Control Panels ........................................... 2-13 Dilution Control Panel ....................................... 2-13 FLW6 Flow Panel .............................................. 2-13 5 Channel Calibrator ......................................... 2-14 Sample Gas Distribution Module ...................... 2-14

PagePortable Gas Analyzers ....................................... 3-3 ECOM-AC Plus ................................................... 3-3 Testo 350 ............................................................ 3-4 Testo 330 ............................................................ 3-5 Testo 335 ............................................................ 3-5Portable Analyzers .............................................. 3-6 Testo 880 ............................................................ 3-6

PageFilter Holders & Frits ........................................... 4-3 47 mm Stainless Steel Filter Holder ................... 4-3 47 mm Tefl on Filter Holder .................................. 4-3 Cartridge Style Stainless Steel Filter Holder ....... 4-3 Fritted Holder ...................................................... 4-3 Disposable In line Filter ........................................ 4-3Peristaltic Pumps and Sample Pumps ............... 4-4 ADI Pumps .......................................................... 4-4 Gast Pumps ........................................................ 4-4 KNF Pumps ......................................................... 4-4 Masterfl ex Pumps ............................................... 4-4 Thomas Pumps ................................................... 4-4 Clean Air Pumps ................................................. 4-4Regulators ............................................................ 4-5 Brass Regulators ................................................ 4-5 Stainless Steel Regulators .................................. 4-5Heating Element ................................................... 4-6 Silicone Heaters .................................................. 4-6 High Temperature Glass Heaters ........................ 4-7 High Temperature Cable Heaters ........................ 4-7 Cartridge, Strip & Tubular Heaters ...................... 4-7Temperature Controllers ..................................... 4-8 Fuji Controllers .................................................... 4-8 Watlow Controllers .............................................. 4-8 Clean Air Controllers ........................................... 4-8Tubing and Pipe ................................................... 4-9 Stainless Steel Tubing and Pipe ......................... 4-9 Inconel Tubing and Pipe ..................................... 4-9 Titanium Tubing and Pipe ................................... 4-9 Flexible Tubing .................................................. 4-10 Tefl on® Tubing .................................................... 4-10Accessories ........................................................ 4-11 Tube Compression Fittings ............................... 4-11 Amphenol Connector Parts ..................................4-8 Flowmeters, Solenoids & Solid State Relays .... 4-12 Manometers and Replacement Parts ............... 4-12 Quick Wire Connectors & Equipment Fans ...... 4-14

Page 6: Clean Air Catalog

Sour

ce S

ampli

ng E

quipm

ent

Sour

ce S

ampli

ng E

quipm

ent

Sour

ce S

ampli

ng E

quipm

ent

1-11-11-1Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

All Clean Air Engineering sampling trains con-tain components that are compatible with and comparable to systems currently used in the industry today.

Let the account teams at Clean Air Engineer-ing Express help you assemble these sampling train components required to perform EPA par-ticulate and gaseous sampling. We have all the equipment you need, when you need it.

PageMethod 2 ................................................................ 1-3 Air Velocity Kit ..................................................... 1-3 Pitot Assemblies .................................................. 1-3 Replacement Pitot for Pitot Assemblies .............. 1-3 Traverse Umbilical Cable .................................... 1-3 Solid Thermocouples .......................................... 1-4Method 3 ................................................................ 1-5 Flue Gas Analyzer ............................................... 1-5 Tedlar Bags ......................................................... 1-6 Sample Pump ..................................................... 1-6Method 5 ................................................................ 1-7 Method 5 Sampling Train .................................... 1-7 Cateco Method 5 Sampling Train ........................ 1-9 Isokinetic Control Console ................................ 1-13 Control Console Shipping Case ........................ 1-15 Critical Orifi ce Set .............................................. 1-15 Impinger Outlet .................................................. 1-15 TI 86 Programmed Calculator ........................... 1-16 Replacement Dry Gas Meter ............................. 1-16 Calibration Dry Gas Meter ................................. 1-16 Sample Unit Oven Compartment ...................... 1-17 Cateco Heated Filter Unit ................................. 1-17 Modular Sample Unit ........................................ 1-18 Impinger Compartments .................................... 1-18 Heated Sample Probe ...................................... 1-19 Water-Cooled Sampling Probe ......................... 1-21 Heated Probe Liners ......................................... 1-23 Unheated Probe Liners ..................................... 1-24 Stainless Steel Ball Joint and Socket ................ 1-24 Replacement Pitot for Probe Assemblies .......... 1-25 Method 5 Probe Rewrap Kits ............................ 1-25 Stainless Steel Port Adapter Seal Assembly ..... 1-25 Sample Recovery Kit ......................................... 1-26 Probe Rod Kits and Probe Wash Bottles .......... 1-26 Sample Containers ............................................ 1-26 Method 5 Umbilical Cable ................................. 1-27 Isokinetic Sampling Nozzles ............................. 1-27

SOURCE SAMPLING EQUIPMENT

0032

051621

Page 7: Clean Air Catalog

Source Sampling EquipmentSource Sampling EquipmentSource Sampling Equipment

1-21-21-2

SOURCE SAMPLING EQUIPMENT

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

PageMethod 5 ................................................................ 1-7 Isokinetic Sampling Nozzles Accessories ......... 1-28 Method 5 Ball Joint (O-ring) Glassware Sets .. 1-29 Glassware Shipping Case ................................ 1-29 Individual Ball Joint Glassware and Clamps ..... 1-31 Tefl on® Impingers/Connectors/Filter Holders .... 1-31 Filter Holders, Frits and Clamp Rings ............... 1-32 Tared Filter Media ............................................. 1-33 Filters - Glass, Quartz and Tefl on® .................... 1-34Method 6 .............................................................. 1-35 Method 6 / Vost Control Console ...................... 1-35 Vost Control Console Shipping Case ................ 1-35 Method 6 Midget Sample Unit ........................... 1-36 Method 6 Umbilical Cable ................................. 1-36 Method 6 Individual Glassware ......................... 1-37 Method 6 Glassware Accessories ..................... 1-37 Method 6 Impinger Set ...................................... 1-38 Method 6 Heated Sampling Probe .................... 1-38Method 8A & SO3 ................................................. 1-39 8A & SO3 Controlled Condensation System ..... 1-39 8A & SO3 Probe ................................................ 1-41 8A & SO3 Glassware ......................................... 1-42Method 17 ............................................................ 1-43 Method 17 Probes ............................................. 1-43 Method 17 Umbilical Cables ............................. 1-43 Nozzles, Filter Holders & Associated Items ...... 1-43 Method 17 Train ................................................ 1-44Method 23 ............................................................ 1-45 Method 23 Sampling Train ................................ 1-45Method 29 ............................................................ 1-47 Method 29 Sampling Train ................................ 1-47Method 30B .......................................................... 1-49 Method 30B Control Console ............................ 1-49 Method 30B Gas Conditioner ............................ 1-51 Method 30B Probe ............................................ 1-51Method 201A ........................................................ 1-54 PM10 Cyclone Package .................................... 1-54

SOURCE SAMPLING EQUIPMENT CONTINUED

®

0028

Page 8: Clean Air Catalog

Metho

d 2Me

thod 2

Metho

d 2Me

thod 2

Metho

d 2Me

thod 2

Metho

d 2Me

thod 2

Metho

d 2 SOURCE SAMPLING EQUIPMENT Air Velocity Kit

Pitot Assemblies Pitot Assemblies

Replacement Pitot for Pitot Assemblies Replacement Pitot for Pitot Assemblies

Traverse Umbilical Traverse Umbilical

1-31-31-3Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0051-5 0-5” Air Velocity Kit (8” pitot)0051-5L 0-5” Air Velocity Kit (18” pitot)0051-10 0-10” Air Velocity Kit (18” pitot)

0051-10S 0051-10 with “S” type pitot

Each kit includes: • Stainless steel standard pitot tube• Inclined-vertical manometer• Two (2) 9’ lengths of rubber tubing• Air velocity calculator slide rule• Magnetic mounting clips• Additional gauge oil • Steel carrying case.

Part Number03 - Length (0306 = 6 Ft. Pitot Assembly)

*Custom order lengths always available

Pitot assemblies include: • “S” type pitot• Grounded Stack Thermocouple• Pitot and Thermocouple are shrouded

into a 1” stainless steel sheath• Geometric pitot calibration is included.

Wind tunnel calibration optional• For Overall length add 6” to effective

Part Number03 - Length - E (0306E = 6 Ft. Replacement Pitot)

*Lengths indicate effective length. Overall length add 6”

Geometric calibration is included with re-placement pitot. 1/4” O. D. stainless steel tube construction.

Lightweight umbilical constructed of two polyethylene pitot lines and one polyvi-nyl-coated thermocouple extension wire, wrapped in nylon mesh material.

Part Number0350 - Length (0350 - 25 = 25 Ft. Umbilical)

Page 9: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 2Method 2Method 2

Method 2Method 2Method 2

Method 2Method 2Method 2

Solid Thermocouples

Thermocouples Accessories

1-41-41-4Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0315.5 6” solid thermocouple .250 O. D.03152 27” solid thermocouple .125 O. D. for 2’ effective instrument03153 39” solid thermocouple .125 O. D. for 3’ effective instrument03154 51” solid thermocouple .125 O. D. for 4’ effective instrument03155 63” solid thermocouple .125 O. D. for 5’ effective instrument03156 75” solid thermocouple .125 O. D. for 6’ effective instrument03157 87” solid thermocouple .125 O. D. for 7’ effective instrument03158 99” solid thermocouple .125 O. D. for 8’ effective instrument03159 111” solid thermocouple .125 O. D. for 9’ effective instrument

031510 123” solid thermocouple .125 O. D. for 10’ effective instrument031511 135” solid thermocouple .125 O. D. for 11’ effective instrument031512 147” solid thermocouple .125 O. D. for 12’ effective instrument031513 159” solid thermocouple .125 O. D. for 13’ effective instrument031514 171” solid thermocouple .125 O. D. for 14’ effective instrument

Part Number Item0315-G Type K wire, glass braid insulation, 20 AWG, (900 Deg. F) 0315-P Type K wire, polyvinyl insulation, (stranded) 20 AWG0315-T Type K wire, Tefl on® insulation, 22 AWG, (450 Deg. F)0316-M Plug, type K, standard male0316-F Plug, type K, standard female

0316-MM Plug, type K, mini male0316-FM Plug, type K, mini female

0316-PMSI Type K, standard female, panel mount snap in (1.2”x 0.64” cutout)0316-SM Type K, standard female, panel mount in ½” conduit hole

0316PMMINI Type K, mini female, panel mount snap in (0.66”x 0.32” cutout)

0315G 0315P 0315T

0316M 0316F 0316MM

0316FM 0316SM0316PMSI

0316PMMINI

Clean Air Express has a huge selection of Thermocouples and Thermocouples ac-cessories. Custom Lengths are available.

Type “K” thermocouple, grounded, stainless steel sheath, 1/8”O. D. with standard K-Type male plug. Custom Thermocouple available in as few as three days.

Specifi cation: • Sheath- Stainless steel• Style- Quick Disconnect Stan-

dard Male Plug• Calibration- Type K• Diameter- 0.125 (1/8)”• Junction- Grounded• Continuous Temperature Limit-

1600°F

Page 10: Clean Air Catalog

Metho

d 3Me

thod 3

Metho

d 3Me

thod 3

Metho

d 3Me

thod 3

Metho

d 3Me

thod 3

Metho

d 3 SOURCE SAMPLING EQUIPMENT Flue Gas Analyzer Flue Gas Analyzer Flue Gas Analyzer

1-51-51-5Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0650 Allied cabinet model (A)

06501 Same as 0650 with three contact bubblers06502 Industro model B

06502A Industro model B without solutions

Clean Air Express Flue gas Analyzer rapidly analyzes gas mixtures, specifi cally to determine carbon dioxide, oxygen and carbon monoxide.

Burrell Allied Cabinet Model Gas Analyzer:Graduated 100-ml gas measuring burette, one contact and two auto bubbler absorption pipettes for determining carbon dioxide, oxygen and carbon monoxide levels.

Burrell Industro Model B Gas Analysis System:Graduated 0-21% gas measuring burette, one contact and two auto bubbler absorption pipettes for determining carbon dioxide, oxygen and carbon monoxide levels. Solutions in-cluded.

Features: • The Method 3 INDUSTRO-B is a simplifi ed instrument for the rapid and accurate fi eld analysis of gas mixtures.• For the determination of carbon dioxide, oxygen and carbon monoxide in gas mixtures.• Commonly used in the analysis of chimney gases for the regulation of combustion in coal-, oil-, and gas-fi red

furnaces.• It can also be used for combustion control, furnace atmosphere analysis, air-leak detection, research and plant

control, calibration of control instruments, and EPA testing.• Minimum number of glass parts combined with metal components for rugged fi eld applications.• Two auto-bubbler pipettes and one contact pipette.• Bulb type burette, 50 ml. graduated 0 to 21% in 0.2%.• Carrying case• Operating instructions• Price also includes one 3 ounce bottle of each Reagent.• Reagents are: Oxsorbent, Di-Sorbent, Cosorbent and Burette Solution.• DIMENSIONS: 15 inches high x 9 inches wide x 4 inches deep.• WEIGHT: 10 pounds

Page 11: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 3Method 3Method 3

Method 3Method 3Method 3

Method 3Method 3Method 3

Tedlar® Tedlar® Tedlar Bags® Bags®

Sample Pump

1-61-61-6Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0728 Sample Pump

Sample Bag Size Part NumberHose Barb Fitting Septum Fitting

7” x 7” (1 liter) 0604T 0604SEP12”x 12” (4 liter) 0607 0607SEP

15”x 15” (8.5 liter) 0605 0605SEP24”x 24” (40 liter) 0608 0608SEP 24”x 36” (50 liter) 0606 0606SEP

30”x 36” (100 liter) 0609 0609SEP

Unlike other sample bag materials, Tedlar® fi lm resists gas permeation - both into and out of the bag, assuring sample integrity for all applications. Tedlar® is rated for continuous use from -98 to 225 F. This wide range of operation allows for use in very cold or very hot environments including stacks, vents, and fl ues. Tedlar® fi lm is inert to a wide range of chemicals. Tedlar® Bags are referenced for many EPA methods, including Methods 3, 18 and 40. *Note: We recommend shipping fi lled Tedlar® bags in a rigid carton to prevent damage/discharge during shipping. Do not ship sample bags by air unless the cargo cabin is pressurized. Do not overfi ll sample bags - avoid fi lling the bag to more than 80% of its maximum volume. At the end of the sampling period, turn the pump off and close the valve on the bag.

Single head, Tefl on® lined sample pump mounted in a rugged metal enclosure. Includes 0.5 - 5.0 LPM fl ow meter with stainless steel valve, Replaceable in-line fi lter, Front panel mounted on/off switch and circuit breaker, Inlet and outlet have ¼” SS compression fi ttings.

Standard RobertsBarbed Valve

Optional Twist Valve w/ Septum

Page 12: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT Method 5 Sampling Train

1-71-71-7Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0028 Isokinetic Control Console with Pump0032 Sample Oven Compartment0033 Impinger Compartment

05003B 3” Glassware Kit Ball Joint or Ball Joint O-Ring0034 Stainless Steel Impinger Outlet

036050QC 50’ Umbilical Cable with Stainless Steel Quick Connects0106BS 6’ Stainless Steel Heated Method 5 Probe with Liner and Geometric Calibration Report

0140 Stainless Steel Probe Port Adaptor Seal Assembly0400NS Complete Set of Stainless Steel Nozzles (1/8”, 3/16”, 1/4", 5/16”, 3/8”, and 1/2") with nuts and ferrules

0156 Sample Recovery Kit0621 8.5 cm Glass Fiber Filters (Box of 100)

• Power Requirement: 120V and 220V confi gurations in stock• Thermocouple connections: Type K• Cabinets: Welded Aluminum Detachable/Stackable Meter and Pump• Temperature Controllers: Solid State with 6 Channel Selector • *Method 5 Train Components Also Available Separately.

The Clean Air Method 5 Train is the benchmark of the industry. It is suited to perform isokinetic particulate testing Referencing Federal EPA 40 CFR 60, Appendix A, Method 5 -“Determination of Particulate Emissions From Stationary Sources.” Other pollutants can be col-lected in the impinger portion of the system providing the proper reagent is utilized. A Method 5 Train is the ba-sic equipment for several EPA Reference Methods. Ask your Clean Air Express customer Service Representa-tive for details on the accessories needed to perform Methods 4, 5, 6, 8, 8A, 5I, 17, 23, 26, and 29.

Part Number 0100-5

Page 13: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

Method 5 Sampling Train Diagram

1-81-81-8

4 Impinger Compartment#0033

Standard Impinger Assembly(Greenburg Smith) #05755

Modified Impinger Assembly#05750

Method 5 Sampling Train

Isokinetic Control Console#0028

3" M5 Filter Assembly28\12 #0509BTFE

Cyclone Bypass 28 \12#0504

M5 Probe, Liner and Nozzle

Stack Wall

Port Seal Adapter#0140

M5 Sample Oven#0032

Monorail Support

Method 5 Umbilical

UX

AVACUUM

P

MU

P

250

250

250

F LOW CONT ROL

+

-

1

8

32

76

45

910

8888

Double "L" Connector 28\12 #0506L

180 Deg.Connector28\12 #0505

Impinger Outlet 28 \12#0034

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 14: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-91-91-9

Cateco Method 5 Sampling Train

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The Method 5 Cateco Sampling Train is similar to the Method 5 train except that it replaces the Modular Sample Unit with a more versatile Cateco Heated Fil-ter Unit. Separating the probe and heated fi lter from the glassware makes this train ideal for testing vertical and hard to access locations. The Clean Air Cateco Method 5 Train is suited to perform isokinetic particulate test-ing Referencing Federal EPA 40 CFR 60, Appendix A, Method 5 -“Determination of Particulate Emissions From Stationary Sources.” Other pollutants can be col-lected in the impinger portion of the system providing the proper reagent is utilized. Many components of the Cateco Method 5 Train are also basic equipment for several other EPA Reference Methods. Ask your Clean Air Express customer Service Representative for details about the accessories needed to perform Methods 4, 5, 6, 8, 8A, 5I, 17, 23, 26, and 29.

Part Number Item0028 Isokinetic Control Console with Pump0035 Cateco Heated Sample Oven Compartment0033 Impinger Compartment

0500C 3” Cateco Ball Joint or Ball Joint O-Ring Glassware Set00368 8.5 cm stainless steel fi lter assembly0034 Stainless Steel Impinger Outlet

036050QC 50’ Umbilical Cable with Stainless Steel Quick Connects0361EXT 10’ Cateco Extension0106BS 6’ Stainless Steel Heated Method 5 Probe with Liner and Geometric Calibration Report

0140 Stainless Steel Probe Port Adaptor Seal Assembly0400NS Complete Set of Stainless Steel Nozzles (1/8”, 3/16”, 1/4", 5/16”, 3/8”, and 1/2") with nuts and ferrules

0156 Sample Recovery Kit0621 8.5 cm Glass Fiber Filters (Box of 100)

• Power Requirement: 120V and 220V confi gurations in stock• Thermocouple connections: Type K• Cabinets: Welded Aluminum Detachable/Stackable Meter and Pump• Temperature Controllers: Solid State with 6 Channel Selector • *Method 5 Train Components Also Available Separately.

Part Number 0100-C5

Page 15: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

Cateco Method 5 Sampling Train Diagram

1-101-101-10

4 Impinger Compartment#0033

Standard Impinger Assembly(Greenburg Smith) #05755

Isokinetic Control Console#0028

Cateco Method 5 Sampling Train

Cateco Umbilical ExtensionStack Wall

Port Seal Adapter#0140

M5 Probe, Liner and Nozzle

Cateco Heated Filter Oven#0035

3" M5 Cateco Filter Assembly28/12 #0037

-

+

Modified Impinger Assembly#05750

250

250

250

8888

Method 5 Umbilical

FLO W CONTROL

Impinger Outlet 28/12#0034

180 Deg.Connector28/12 #0505

Socket to Hose BarbConnector 28/12#0508

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 16: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-111-111-11

Method 5 CE Sampling Train

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 0100-5-220VCE

Part Number Item0028220MCE Isokinetic Control Console with Pump – CE Marked0032220CE Sample Oven Compartment – CE Marked

0033 Impinger Compartment05003B 3” Glassware Kit Ball Joint or Ball Joint O-Ring

0034 Stainless Steel Impinger Outlet036050QCCE 50’ Umbilical Cable with Stainless Steel Quick Connects – CE Marked0106BS220CE 6’ Stainless Steel Heated Method 5 Probe with Liner and Geometric Calibration Report – CE Marked

0140 Stainless Steel Probe Port Adaptor Seal Assembly0400NS Complete Set of Stainless Steel Nozzles (1/8”, 3/16”, 1/4", 5/16”, 3/8”, and 1/2") with nuts and ferrules

0156 Sample Recovery Kit0621.26 8.26 cm Glass Fiber Filters (Box of 100)

• Power Requirement: 220V confi gurations in stock• Thermocouple connections: Type K• Cabinets: Welded Aluminum Detachable/Stackable Meter and Pump• Temperature Controllers: Solid State with 6 Channel Selector • *Method 5 Train Components Also Available Separately.

The Clean Air Method 5 Train is suited to perform isokinetic particulate testing referencing US EPA 40 CFR 60, European prEN 13284-1. It is also compatible with Standard ISO 9096 for sampling particulates emissions from chimneys or smoke stacks. Condensable pollutants can be collected in the impingers per EPA Method 202.

Page 17: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

Method 5 CE Sampling Train Diagram

1-121-121-121-121-121-12

4 Impinger Compartment#0033

Standard Impinger Assembly(Greenburg Smith) #05755

Modified Impinger Assembly#05750

Method 5 Sampling Train

Isokinetic Control Console#0028

3" M5 Filter Assembly28\12 #0509BTFE

Cyclone Bypass 28 \12#0504

M5 Probe, Liner and Nozzle

Stack Wall

Port Seal Adapter#0140

M5 Sample Oven#0032

Monorail Support

Method 5 Umbilical

UX

AVACUUM

P

MU

P

250

250

250

F LOW CONT ROL

+

-

1

8

32

76

45

910

8888

Double "L" Connector 28\12 #0506L

180 Deg.Connector28\12 #0505

Impinger Outlet 28 \12#0034

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 18: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-131-131-13

Isokinetic Control Console

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0028 Control Console and Pump

0028-220M Control Console and Pump(220 V Metric)0028-110M Control Console and Pump(110 V Metric)0028-PMP Pump Assembly US 120V0028-P220 Pump Assembly Metric 220V

Specifi cations• Sample Pump: Pulsation Free 1/3 HP Rotary Vane Vacuum

Pump (26” Hg Vac, 2 cfm @ 15” Hg) 120 V / 230 V, 50 /60 Hz • Dry Gas Meter: S-275 (L/rev., Ft./rev., & m3/rev. options)• Manometer: 8” Dual Incline with Stainless Steel Quick-Con-

nects Solenoid Valves Provide Zeroing Ability at any Time• Timer: Digital LCD w/ Battery Backup (Displays h, m, s)• Umbilical Power Output Connection: Amphenol 4-pin Fused• Auxiliary Power Output Connection: 3 pin 120 V Receptacle• Pitot Inlet Connections: 3/8” Stainless Steel Quick Connects• Sample Inlet Connection: 1/2”” Stainless Steel Quick Connect

w/ Stainless Steel Valves• Pumpless: Integrated Gas Sample System• Temperature Controllers: Solid State for Probe, Filter, and 6

Channel Selector • Thermocouple Connections: K-Type Panel Mount• Cabinets: Welded Aluminum, Detachable/Stackable Meter and

Pump• Quick-Release: Access Doors for Both Meter and Pump• External Dimensions (h x w x d): 17.5” x 12” x 27” (445 mm x

305 mm x 686 mm)• Weight: 70 lbs. (32 kg)

The Clean Air Express Method 5 Isokinetic Control Console is de-signed to allow monitoring and control of temperatures, pressures, gas velocities and sample fl ow rates to maintain Isokinetic sam-pling conditions. Top quality components and fi eld proven durabil-ity make this the most dependable control console you can buy. Compatible with most systems currently in use. Suitable for EPA methods: 4, 5, 5I, 6, 8, 8A, 13, 17, 23, 26, 29, and many more (with proper accessories).

Page 19: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-141-141-14

Isokinetic Control Console Diagram

3

1

I .G.S.

SAMPLEINLET

PITOT

+

-

2

P

MU

VACUUM

P

LOOSEN

PUMP

UX

A

PRESSURE

VACUUM

89

10

76

45

FINE

CLOSE

COARSE

OPEN

FLOW CONTROL

250 FILTER

5AUXILIARY

IMP.

43FILTER

2PROBE OUTLETSTACK

1

+ LEAK CHECKVALVESPUMP

S TACK

250DGM. INLETIMP. OUTLET

DGM. OUTLETAUX IL IARYAMBIE NT T EMP.

POWER

PROBE 250

START

STOP

R ESETMIN. SEC.

8888

9922

91301

91301

91301

9135913591369134

9133K 9103

91031

91031 00588

0419SNV

99381

00170316PMSI

9141A 9141A

0757

0418SBU9501

95189507

9418

9110SR

9444DBL6

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

0028-PMP

Page 20: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-151-151-15

Control Console Shipping Case

Critical Orifi ce Set

Impinger Outlet

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0028MC Meter Box Shipping Case0028PC Pump Box Shipping Case

Part Number Item0020 Critical orifi ce set

0020-S Individual critical orifi ce

Part Number Item0034 Impinger Outlet 3/8” tube outlet connection

0034QC Impinger Outlet 1/2" Quick Connect outlet *Optional quick connect fi ttings available

ATA rated durable fi berglass and wood shipping case. Protects meter and pump from shipping damage.

To be used as a dry gas meter calibration reference, the Clean Air Engineering Ex-press Critical orifi ce offers 1/2” stainless steel quick connects with an internal stain-less steel orifi ce plate. A set contains six orifi ces ranging from 10- 34 LPM, as pre-scribed in EPA Method 5. Each set comes complete with a dust-proof/moisture proof lifetime guaranteed carrying case. Individual calibration sheets are also included.

The impinger outlet is connected to the last impinger in the sample train and provides a rigid mount for the sample umbilical. Designed to fi t the quick release clamp on the Clean Air Express impinger compartments. Stainless steel construction, 28/12 ball joint socket inlet connection, Brass check valve, 3/8” tube or 1/2” quick connect outlet connection and 1/4” type K thermocouple.

Page 21: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-161-161-16

TI 86 Programmed Calculator

Calibration Dry Gas Meters

Replacement Dry Gas Meters

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

S275 dry gas meter calibrated specifi cally for use as a secondary standard when calibrating other dry gas meters or metering consoles. Includes: stainless steel fi ttings and dial thermometer.

Part Number Item0390 U.S. Secondary Standard0392 Metric Secondary Standard

Part Number Item0028D S 275 Replacement Dry Gas Meter Assembly

0028DM S 275 Metric Replacement Dry Gas Meter Assembly for M-5 Meter9922 S 275 .1 CU. FT./rev. Dry Gas Meter 99221 S 275 m3/rev. Dry Gas Meter 0393 S 275 Liter/rev. Dry Gas Meter

Replacement dry gas meters are available for use in many of today’s systems. Clean Air Express can also rebuild and calibrate your present meter control console.

Part Number Item0004 Calculator with Programs

Pre-programmed with Isokinetic stack sampling calculations. Programmed in English and metric units.

Programs Included:• Traverse Points• Stack Gas Moisture Content• Stack Gas Velocity and Volumetric Flow Rate• Nozzle Size and K-Factor• Stack Gas Saturation Moisture Content• Critical Orifi ce Field Calibration• Post-Test Isokinetic

Page 22: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-171-171-17

Sample Unit Oven Compartment

Cateco Heated Filter Unit

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0032 120V Sample Unit Oven Compartment

0032-220 220V Sample Unit Oven Compartment

Part Number Item0035 120V Cateco Heated Filter Unit

0035-220 220V Cateco Heated Filter Unit

The double-wall aluminum constructed heated fi lter unit is an excellent alternative to the much larger Modular Sample Unit. It is ideally suited for applications that require vertical sampling. The case is extremely lightweight and durable, and heats quickly with its small heating area. The probe is mounted through an aluminum arm identical to those used on the Modular Sample Unit. Electrical connections are compatible with those used in the industry. It is designed for use with Clean Air Express stainless steel or glass fi lter holders.

The light-weight aluminum sample unit oven compartment is used for testing methods that require an out-of-stack heated fi lter. This unit features a rugged cast aluminum probe support arm, monorail support hanger, Impinger compartment slide rails, and two access doors. Compatible with industry standard umbilicals, probes, and Impinger compartments.

Specifi cations• Voltage Requirement: 120 V / 220V• Power Requirement: 300 W• Umbilical Power Input Connection: Amphenol 4-pin• Auxiliary Power Output Connection: 3 pin 120 V receptacle• Thermal Couple Connection: K-Type panel mount• External Dimensions (h x w x d): 7.5” x 9.25” x 16.25” • Internal Dimensions (h x w x d): 6.25” x 7.25” x 7.25” • Weight: 7 lbs. (3.2 kg)

Specifi cations• Voltage Requirement: 120 V / 220V• Power Requirement: 500 W• Auxiliary Power Output Connection: 3 pin 120 V receptacle• Probe Power Output Connection: 3 pin 120 V receptacle• Thermal Couple Connection: K-Type panel mount• External Dimensions (h x w x d): 23.5” x 10.75” x 17.5”(597 mm x 273

mm x 444 mm)• Internal Dimensions (h x w x d): 19.5” x 8.5” x 8.25” (495 mm x 216

mm x 210 mm)• Weight: 18 lbs. (8.2 kg)

Page 23: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-181-181-18

Modular Sample Unit Diagram

Impinger Compartments

Modular Sample Unit

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0033 4 Impinger Compartment0030 8 Impinger Compartment

Part Number Item0031 120V Modular Sample Unit

0031-220 220V Modular Sample Unit

The Modular Sample Unit consist of a Sample Unit Oven Compartment and a 4 or 8 Impinger Compartment. Includes quick release system.

Page 24: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-191-191-19

Method 5 Heated Sampling Probe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

With 28/12 Ball Joint / 5/8” Chamfered End LinerPart Number Liner Material Item

0104-B- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106-B- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108-B- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110-B- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint / 14/35 Male Tapered End LinerPart Number Liner Material Item

0104-BT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106-BT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108-BT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110-BT- (P), (Q), (S), (I),(Titanium) 10’ M-5 ProbeWith 28/12 Ball Joint O-ring / 5/8” Chamfered End Liner

Part Number Liner Material Item0104-BO- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106-BO- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108-BO- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110-BO- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint O-ring / 14/35 Male Tapered End LinerPart Number Liner Material Item0104-BOT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106-BOT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108-BOT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110-BOT- (P), (Q), (S), (I),(Titanium) 10’ M-5 ProbeWith 5/8” Chamfered End / 14/35 Male Tapered End Liner

Part Number Liner Material Item0104-T- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106-T- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108-T- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110-T- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

Clean Air Express Method 5 Heated Sampling Probes feature a unique sheathed design that allows quick and easy re-placement of pitot, stack thermocouple, and liner. Geometric calibration of pitot is included: wind tunnel calibration is also an option. *Note: Standard probes use a fl exible silicone heater (Max temp. 500 deg. F). Optional high temperature heaters are available. *Note: Lengths below indicate effective length. To determine overall length, add 12”. Custom probe lengths and materials are available. Please specify liner material when ordering.

Heated Sampling Probe Includes:• Heated Liner - 28/12 ball joint, 28/12

ball joint o-ring, 14/35 male taper or 5/8” chamfered end.

• Type K probe liner thermocouple with standard male plug

• Type K stack thermocouple with stan-dard male plug

• Type “S” pitot

Liner material: (P) Pyrex (Q) Quartz (S) 316 stainless steel (I) Inconel (Titanium) Titanium

Power Requirement:120V AC or 220V confi gurations are avail-able.

Page 25: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-201-201-20

Method 5 Heated Sampling Probe Diagram

Prob

e en

d co

mpl

etel

y w

elde

d sh

utto

pre

vent

any

pos

itive

or n

egat

ive

pres

sure

loss

5/8"

tube

nut

sec

urel

yw

elde

d to

line

r she

ath

Easi

ly re

plac

ed s

ampl

e lin

er

Inte

rnal

hea

ting

elem

ent n

ot a

ttach

ed to

line

r

1" L

iner

she

ath

fits

mos

t mod

ular

sam

ple

case

pro

be s

uppo

rt ar

ms

Type

K p

robe

line

rth

erm

ocou

ple

with

stan

dard

mal

e pl

ug

Ther

moc

oupl

e se

aled

with

tube

uni

onto

pre

vent

inac

cura

te th

erm

ocou

ple

resp

onse

1-1/

4" S

ch. 5

out

er s

heat

h pr

ovid

es a

n ex

celle

ntsu

rface

for s

ealin

g pr

obe

to p

ort w

hile

als

oad

ding

sup

erio

r pro

tect

ion

and

stab

ility

2" p

ort a

dapt

er s

eal a

ssem

bly

help

s to

sec

ure

and

seal

pro

be

Gro

unde

d, re

plac

eabl

e,Ty

pe K

sta

ck th

erm

ocou

ple

with

sta

ndar

d m

ale

plug

All s

tain

less

ste

el c

onst

ruct

ion

"S" t

ype,

repl

acea

ble,

adj

usta

ble,

one-

piec

e pi

tot t

ube

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 26: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-211-211-21

Method 5 Water-Cooled Sampling Probe

With 28/12 Ball Joint / 5/8” Chamfered End LinerPart Number Liner Material Item

0104W-B- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106W-B- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108W-B- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110W-B- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint / 14/35 Male Tapered End LinerPart Number Liner Material Item0104W-BT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106W-BT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108W-BT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110W-BT- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12 Ball Joint O-ring / 5/8” Chamfered End LinerPart Number Liner Material Item0104W-BO- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106W-BO- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108W-BO- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110W-BO- (P), (Q), (S), (I),(Titanium) 10’ M-5 ProbeWith 28/12” Ball Joint O-ring / 14/35 Male Tapered End Liner

Part Number Liner Material Item0104W-BOT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106W-BOT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108W-BOT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110W-BOT- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 5/8” Chamfered End / 14/35 Male Tapered End LinerPart Number Liner Material Item

0104W-T- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0106W-T- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0108W-T- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0110W-T- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

All Clean Air Express Method 5 water-cooled probes feature 316 stainless steel construction; a replaceable probe liner; liner heater; pitot and stack thermocouple. Geometric calibration of pitot is included: wind tunnel calibration is optional.*Note: Standard probes use a fl exible silicone heater (Max temp. 500 deg. F). Optional high temperature heaters are available. *Note: Below lengths indicate effective length. To determine overall length, add 21 ¼”. Custom order lengths and materi-als are also available. Please specify liner material when ordering.

Sampling Probe Includes:• Heated Liner - 28/12 ball joint, 28/12

ball joint o-ring, 14/35 male taper or 5/8” chamfered end.

• Type K probe liner thermocouple with standard male plug

• Type K stack thermocouple with stan-dard male plug

• Type “S” pitot

Liner material: (P) Pyrex (Q) Quartz (S) 316 stainless steel (I) Inconel (Titanium) Titanium

Power Requirement:120V AC or 220V confi gurations are avail-able.

Page 27: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-221-221-22

Method 5 Water-Cooled Sampling Probe Diagram

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 28: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-231-231-23

Method 5 Heated Probe Liners

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

With 28/12 Ball Joint / 5/8” Chamfered End LinerPart Number Liner Material Item

0204-B- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0206-B- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0208-B- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0210-B- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint / 14/35 Male Tapered End LinerPart Number Liner Material Item

0204-BT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0206-BT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0208-BT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0210-BT- (P), (Q), (S), (I),(Titanium) 10’ M-5 ProbeWith 28/12 Ball Joint O-ring / 5/8” Chamfered End Liner

Part Number Liner Material Item0204-BO- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0206-BO- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0208-BO- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0210-BO- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint O-ring / 14/35 Male Tapered End LinerPart Number Liner Material Item0204-BOT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0206-BOT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0208-BOT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0210-BOT- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 5/8” Chamfered End / 14/35 Male Tapered End LinerPart Number Liner Material Item

0204-T- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0206-T- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0208-T- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0210-T- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

Clean Air Express Method 5 Heated Probes Liners come in a variety of sizes and materials. Made for professionals and designed for use in Clean Air Express Method 5 Probes but will fi t all 5/8” OD probe liner applications *Note: Standard probes use a fl exible silicone heater (Max temp. 500 deg. F). Optional high temperature heaters are available. *Note: Lengths below indicate effective length of Method 5 Probe Assembly. Custom order lengths and materials are also available. Please specify liner material when ordering.

Heated Probe Liner:• Liner Connection - 28/12 ball joint,

28/12 ball joint o-ring, 4/35 male taper or 5/8” chamfered end.

Liner material: (P) Pyrex (Q) Quartz (S) 316 stainless steel (I) Inconel (Titanium) Titanium

Power Requirement:120V AC or 220V confi gurations are avail-able.

Page 29: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-241-241-24

Method 5 Unheated Probe Liners

Stainless Steel Ball-Joint and Socket

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

With 28/12 Ball Joint / 5/8” Chamfered End LinerPart Number Liner Material Item

0224-B- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0226-B- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0228-B- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0230-B- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint / 14/35 Male Tapered End LinerPart Number Liner Material Item

0224-BT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0226-BT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0228-BT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0230-BT- (P), (Q), (S), (I),(Titanium) 10’ M-5 ProbeWith 28/12 Ball Joint O-ring / 5/8” Chamfered End Liner

Part Number Liner Material Item0224-BO- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0226-BO- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0228-BO- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0230-BO- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 28/12” Ball Joint O-ring / 14/35 Male Tapered End LinerPart Number Liner Material Item0224-BOT- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0226-BOT- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0228-BOT- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0230-BOT- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

With 5/8” Chamfered End / 14/35 Male Tapered End LinerPart Number Liner Material Item

0224-T- (P), (Q), (S), (I),(Titanium) 4’ M-5 Probe0226-T- (P), (Q), (S), (I),(Titanium) 6’ M-5 Probe0228-T- (P), (Q), (S), (I),(Titanium) 8’ M-5 Probe0230-T- (P), (Q), (S), (I),(Titanium) 10’ M-5 Probe

Clean Air Express Method 5 Unheated Probes Liners come in a variety of sizes and materials. *Note: Below lengths indicate effective length of Method 5 Probe Assembly. Cus-tom order lengths and materials are also available. Please specify liner material when ordering.

Unheated Probe Liner:• Liner Connection - 28/12 ball joint,

28/12 ball joint o-ring, 4/35 male taper or 5/8” chamfered end.

Liner material: (P) Pyrex (Q) Quartz (S) 316 stainless steel (I) Inconel (Titanium) Titanium

Part Number Item9603 Stainless Steel Ball-Joint with or without O-Ring9604 Stainless Steel Socket Joint

Page 30: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-251-251-25

Replacement Pitot for Probe Assemblies

Method 5 Probe Rewrap Kits

Stainless Steel Port Adapter Seal Assembly

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0140 Port Adaptor Seal Assembly. 2” NPT01404 Port Adaptor Plate – 4” fl ange01406 Port Adaptor Plate – 6” fl ange

01404SP 4” Dia. Silicon PlugFor use with Clean Air Express sheathed Method 5 probe.

Part Number Item01492 Silicone heater for 2’ effective probes01495 Silicone heater for 3’-5’ effective probes01496 Silicone heater for 6’ effective probes01499 Silicone heater for 7’-9’ effective probes

014914 Silicone heater for 10’ effective probes0150-2 Rewrap kit for 2’-10’ effective probes

0150-12 Rewrap kit for 12’-20’ effective probesKits include heating element, tape and connectors.

Part Number Material Item0304-P- (S),(I),(Titanium) 4’ Replacement Pitot0306-P- (S),(I),(Titanium) 6’ Replacement Pitot0308-P- (S),(I),(Titanium) 8’ Replacement Pitot0310-P- (S),(I),(Titanium) 10’ Replacement Pitot0312-P- (S),(I),(Titanium) 12’ Replacement Pitot

Geometric calibration included with replacement pitot. Note: Lengths indicate effec-tive length. To determine overall length add 6”. Custom order lengths are also avail-able.*Materials of construction: (S) stainless steel (I) Inconel (Titanium)

Page 31: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-261-261-26

Sample Recovery Kit

Probe Rod Kits and Probe Wash Bottles

Sample Containers

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item

0156

Sample recovery kit for 10’ probe contains:• (1) 10’ Probe rod kit• (5) Nozzle Brushes• (2) 500 ml wash-bottles• (12) 250 ml Polyethylene sample bottles

0157

Sample recovery kit for 15’ probe contains:• (1) 15’ Probe rod kit• (5) Nozzle Brushes• (2) 500 ml wash bottles• (12) 250 ml Polyethylene sample bottles

Probe Rod KitsPart Number Item

0151-5 5’ Probe Rod Kit0151-10 10’ Probe Rod Kit0151-15 15’ Probe Rod Kit0151-20 20’ Probe Rod Kit0155-N Nylon Brush0155-T Tefl on® Patch

Part Number ItemAmber Bottles with Tefl on® Liner

0600 250 ml bottle, case of 120601 500 ml bottle, case of 120602 950 ml bottle, case of 12

Amber Bottles with Tefl on® Liner0603 250 ml bottle, case of 720604 500 ml bottle, case of 48

Probe Wash BottlesPart Number Item

0600-W 500 ml Poly wash bottle0603 250 ml Poly wash bottle

0602-W 500 ml Tefl on® wash bottle

Kit includes Tefl on® rod with rod guide and nylon brush. Brushes can be ordered separately.

Page 32: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-271-271-27

Method 5 Umbilical Cable

Isokinetic Sampling Nozzle Accessories

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number ItemStandard

0360-25 25’ Length0360-50 50’ Length

0360-100 100’ LengthWith Quick Connect

0360-25QC 25’ Length0360-50QC 50’ Length

0360-100QC 100’ Length

Lightweight umbilical line constructed of one gum rubber line, two polyvinyl pitot lines, one fi ve-conductor electrical line, and fi ve ther-mocouple extension wires. All sheathed in a durable fl exible nylon mesh. Available with or without stainless steel quick connects.

Nozzle AccessoriesPart Number Item

0421TU 5/8” Tefl on® union0421TRU 5/8”-1/2” Tefl on® reducing union0421SRU 5/8”-1/2” stainless steel reducing union0421TF 5/8” Tefl on® ferrules0421G 5/8” Graphite ferrules

0421SU 5/8” Stainless steel union0430 Nylon nozzle brush

99451100 Nozzle Case

Page 33: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-281-281-28

Isokinetic Sampling Nozzles

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Clean Air Express Isokinetic Sampling Nozzles are avail-able in Pyrex, Quartz, Stainless Steel, or Inconel. When using quartz or Pyrex nozzles, we suggest using a Tefl on® union. Please specify material when ordering.

Nozzles are available in the following materials: Pyrex (P), Quartz (Q), 316 Stainless Steel (S), Inconel (I), Tapered Quartz and Tapered Pyrex.

Button Hook Nozzle with 5/8” ShankPart Number Material Nozzle Size

0401 (P), (Q), (S), (I) 1/8”0402 (P), (Q), (S), (I) 3/16”0403 (P), (Q), (S), (I) 1/4"0404 (P), (Q), (S), (I) 5/16”0405 (P), (Q), (S), (I) 3/8”0413 (P), (Q), (S), (I) 7/16”0406 (P), (Q), (S), (I) 1/2"

Button Hook Nozzle with 14/35 Female TaperPart Number Material Nozzle Size

N04T- (P), (Q) 1/8”N06T- (P), (Q) 3/16”N08T- (P), (Q) 1/4"N10T- (P), (Q) 5/16”N12T- (P), (Q) 3/8”N14T- (P), (Q) 7/16”N16T- (P), (Q) 1/2"

Button Hook Nozzle Sets with 5/8” ShankPart Number Material Nozzle Size

NS7- (P), (Q), (S), (I) 1/8,3/16,1/4,5/16,3/8,7/16,1/2Button Hook Nozzle Sets with 14/35 Female Taper

Part Number Material Nozzle SizeNS7T- (P), (Q) 1/8,3/16,1/4,5/16,3/8,7/16,1/2

Page 34: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-291-291-29

Method 5 Glassware

Glassware Shipping Case

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

# 05003 Method 5 3” 28/12 Ball Joint Glassware Set Includes Qty Part Number Item1 0509B 3” fi lter assembly with clamp ring and glass frit1 0506L Double “L” connector1 0513 Cyclone Bypass1 05755 Impinger Assembly3 05750 Modifi ed Impinger Assemblies 3 0505 180° tube connectors 11 0507 Ball joint screw clamps # 05003B Method 5 3” 28/12 Ball Joint O-Ring Glassware Set Includes

Qty Part Number Item1 0509BTFE 3” fi lter assembly with clamp and Tefl on® frit1 0506L Double “L” connector1 0504 Cyclone Bypass1 05755 Impinger Assembly3 05750 Modifi ed Impinger Assemblies 3 0505 180° tube connectors 11 0507 Ball joint screw clamps

# 05004 Method 5 4” 28/12 Ball Joint Glassware Set Includes Qty Part Number Item

1 0501 4” fi lter assembly with clamp ring and glass frit1 0506L Double “L” connector1 0513 Cyclone Bypass1 05755 Impinger Assembly3 05750 Modifi ed Impinger Assemblies 3 0505 180° tube connectors 11 0507 Ball joint screw clamps

Part Number Item99451600 Shipping case for one set of M5 glassware

*Note: Custom designed shipping cases are available for all Glassware sets.

*Case Not Included

Page 35: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-301-301-30

Cateco Method 5 Glassware

Method 5 Glassware Diagram

Filter Outlet28/12 #0509M

180 Deg. Connector#0505

Modified ImpingerAssembly #05750

Modified ImpingerAssembly #05750

Standard ImpingerAssembly #05755

Impinger Bottle Only#0502B

Modified ImpingerInsert Only#0503I

Modified ImpingerInsert Only#0503I

Double "L" Connector28/12 #0506L

Cyclone Bypass28/12 #0504

Cyclone28/12 #0504C

Screw Clamp28/12 #0507

125 ml Flask28/12 #0504F

Filter Inlet 90 Deg.28/12 #0509F

3" Frit Glass #0509GTeflon #0509T

3" Clamp Ring#0509CR

3" M5 Filter Assembly28/12 # 0509BTFE

Thermowell3" Clamp Ring

Method 5 Glassware

180 Deg. Connector#0505

Assembly #05750Modified Impinger

Screw Clamp28/12 #0507

Modified ImpingerInsert Only#0503I

Assembly #05755Standard Impinger

Assembly #05750Modified Impinger

Modified ImpingerInsert Only#0503I

Impinger Bottle Only#0502B

Double "L" Connector28/12 #0506L3" Frit

Glass #0509GTeflon #0509T

Cateco Filter Inlet 28/12 #0037I

Cateco Filter Outlet28/12 #0038O

3" Clamp Ring#0509CR

3" Cateco M5 Filter Assembly28/12 # 0037

Thermowell

3" Clamp Ring

Cateco Method 5 Glassware

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

# 0500C Method 5 Cateco 28/12 Ball Joint Glassware Set Includes Qty Part Number Item1 05755 Impinger Assembly 3 05750 Modifi ed Impinger Assemblies 3 0505 180’ Connectors1 0508 #28 Socket - 3/8” Hose barb9 0507 Ball joint screw clamps

#0500BC Method 5 Cateco 28/12 Ball Joint O-Ring Glassware Set Includes Qty Part Number Item1 05755 Ball-Joint O-ring Impinger Assembly 3 05750 Modifi ed Ball-Joint O-ring Impinger Assemblies 3 0505 180’ Connectors1 0508 #28 Socket - 3/8” Hose barb9 0507 Ball joint screw clamps

*Filter for Cateco Set sold separately #0037

Page 36: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-311-311-31

Individual Ball Joint Glassware and Clamps

Tefl on® Impingers, Connectors and Filter Holders® Impingers, Connectors and Filter Holders®

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

28/12 Ball Joint O-RingPart Number Item

05750 Impinger w/ modifi ed insert05750I Impinger insert only modifi ed0502-B Impinger bottle only05755 Impinger assembly w/ standard insert05755I Impinger insert only standard0504 Cyclone bypass

0504-C Cyclone (not shown)0504-F 125 ml fl ask (not shown)0505 180º Tube connector0506 90º Tube connector (not shown)

0506-L Double “L” connector0507 Screw clamp 28/120508 Socket to 3/8” hose barb connector0510 Filter Bypass

Part Number Item Part Number Item0553 375 ml impinger with ½” ports 0552-L 90º Bend (long)

0553-T Transfer cap 0552-S 90º Bend (short)0554 600 ml Impinger with 5/8” ports 0550 180º Tube Connector

0554-T Transfer Cap 0551 2.3 mm Orifi ce tip (1/2” tubing)0558 47 mm Tefl on® Filter Holder

0575

0

0575

0I

0502

B

0575

5

0575

5I

0504 0505

0506-L 0507

0508 0510

Page 37: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-321-321-32

Filter Holders, Frits and Clamp Rings

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

4” Filter 28/12 Glass Ball Joint O-RingPart Number Item

0501 4” Filter assembly (complete)0501-F 4” Filter inlet (90 Deg. Elbow 28/12 Ball Joint socket)0501-M 4” Filter outlet0501-G 4” Glass frit0501-T 4” Tefl on® frit

0501-CR 4” Clamp ring3” Filter 28/12 Glass Ball Joint with O-Ring

Part Number Item0509-B 3” Filter assembly (complete)0509-F 3” Filter inlet (90 Deg. Elbow 28/12 Ball Joint socket)0509-M 3” Filter outlet0509-G 3” Glass frit0509-T 3” Tefl on® frit

0509-CR 3” Clamp ring3” Cateco Filter 28/12 Glass Ball Joint with O-Ring

Part Number Item0037 3” Cateco Filter assembly (complete)

0038-I 3” Filter inlet (28/12 Ball Joint Cup)0038-O 3” Filter outlet0509-G 3” Glass frit0509-T 3” Tefl on® frit

0509-CR 3” Clamp ring3” Stainless Steel Filter

Part Number Item00368 3” SS Filter assembly (complete)

0560-I1 3” SS Filter inlet (28/12 Ball Joint Cup)0560-O1 3” SS Filter outlet 0509-G 3” Glass frit0509-T 3” Tefl on® frit

0509-CR 3” Clamp ring

0501

0509-B

0037

00368

0501-F

0509-F 0038-I 0560-I1 0560-O1 0509-M

0501-M

0509-G

0501-G

0509-T

0501-T

0509-CR

0501-CR

Page 38: Clean Air Catalog

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5Me

thod 5

Metho

d 5 SOURCE SAMPLING EQUIPMENT

1-331-331-33

Tared Filter Media

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Description Price8.26 cm Dia. 934AH Glass Fiber $25.008.26 cm Dia. QAT UP Quartz Fiber $30.008.26 cm Dia. Tefl on® Fiber $30.004.7 cm Dia. 934AH Glass Fiber (w/SS Gaskets) $25.004.7 cm Dia. QAT UP Quartz Fiber $30.004.7 cm Dia. Tefl on® Fiber $30.008” x 10” 934AH Glass Fiber $30.008” x 10” QAT UP Quartz Fiber $35.00M17 Alundum Thimbles $100.0037 mm Acetate $25.00

Our laboratories are staffed by professionals who em-ploy comprehensive quality control measures to assure the highest quality results, guaranteed. We’re committed to serving our customers with the highest value possible. Our unique experience, gained from over 30 years of environmental sampling and analysis, has placed us among the leaders in our fi eld. We continuously refi ne existing methods while developing new test procedures to meet the ever-changing needs of our business and industrial clients.

Clean Air Laboratory Facility Overview Our labs are housed in a custom building incorporating state-of-the-art laboratory features including a specially designed climate control system for optimal instrument performance.

Page 39: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 5Method 5Method 5

Method 5Method 5Method 5

Method 5Method 5Method 5

1-341-341-34

Filters - Glass, Quartz and Tefl on®

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Clean Air Express Filters are available in a variety of ma-terials and sizes. Different fi lter materials are used for various types of method testing. If you are unsure which kind of fi lter media to purchase, call your Clean Air Ex-press customer service representative.

Filters are available in the following materials:Glass, Quartz, Tefl on® (Sizes specifi ed in table below.)

Filter Size Part NumberGlass Quartz Tefl on®

47 mm 0620 0620Q 0620T10 cm / for 4” Filter Holder 0610 n/a n/a8.26 cm / for 3” Filter Holder 0621.26 0621.26Q 0621.26T11 cm 0622 0622Q 0622T8x10 (100ct.) 0623 0623Q 0623T8x10 (10ct) 0623A n/a n/a

Technical Note: Do not use glass fi lters if hydrofl uoric acid or fl uorine compounds are present, as they may etch the glass.

Page 40: Clean Air Catalog

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6 SOURCE SAMPLING EQUIPMENT

1-351-351-351-351-351-35

Method 6 / Vost Control Console

Method 6 / Vost Control Console Shipping Case

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The Model 80 Control Console is a light, compact unit designed to perform EPA methods 6, 6a, 6b, 15, 18, 26 and VOST. This unit is suitable for use with any low fl ow sampling method that requires accurate volume measurement. This rugged lightweight console features built in digital temperature control and indication, vacuum and pressure gauges, dual fl oat rotometer, stainless steel fi ne and coarse valves and internal diaphragm vacuum pump.

Part Number 0080

Specifi cations• Sample Pump: Internal Diaphragm Vacuum Pump• Dry Gas Meter: S-275 L/rev. • Rotometer: Dual Float Glass - 1.24 lpm and 2.54 lpm• Timer: Digital LCD w/ Battery Backup (Displays h, m, s)• Umbilical Power Input Connection: Amphenol 4-pin• Auxiliary Power Output Connection: 3 pin 120 V receptacle• Circuit Protection: Panel Mounted Circuit Breaker Switches• Sample Inlet Connection: 1/4” Stainless Steel Quick-Connects• Temperature Controllers: Solid State for Probe & Filter• Temperature Monitor: LED readout w/ Four-Position Switch• Thermal Couple Connection: K-Type Miniature Panel Mount• Cabinet: 0.095” Welded Aluminum w/ Quick-Release Access

Doors• External Dimensions (h x w x d): 14” x 14” x 11” (356 mm x 356

mm x 279 mm)• Weight: 30 lbs. (13.6 kg)

Part Number Item0080VC Vost Meter Box Shipping Case

ATA style durable fi berglass and wood shipping case. Protects meter and pump from damage.

Page 41: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 6Method 6Method 6

Method 6Method 6Method 6

Method 6Method 6Method 6

1-361-361-361-361-361-36

Method 6 Midget Sample Unit

Method 6 Umbilical Cable

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0065 Midget sample unit0066 Midget impinger tray0067 Midget impinger tray holder

Midget sample unit comes complete with aluminum probe support arm; adjustable probe support arm slide; and insulated impinger tray.

Part Number ItemStandard

0362-10 10’ Umbilical cable0362-25 25’ Umbilical cable0362-50 50’ Umbilical cable

With Quick Connect0362-10QC 10’ Umbilical cable0362-25QC 25’ Umbilical cable0362-50QC 50’ Umbilical cable

Clean Air Express M-6 umbilicals are constructed of one (1) one gum rubber line, three (3) type-K thermocouple lines; and one (1) electrical power line, all wrapped in a durable fl exible nylon mesh material. Stainless steel quick connects available.

Page 42: Clean Air Catalog

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6Me

thod 6

Metho

d 6 SOURCE SAMPLING EQUIPMENT

1-371-371-37

Method 6 Glassware Accessories

Method 6 Individual Glassware

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0034-6 Impinger outlet0066 Midget impinger tray0067 Midget impinger tray holder

Part Number Item0523 Midget modifi ed impinger assembly

0523-I Midget modifi ed impinger insert0524 Midget impinger assembly

0524-I Midget impinger insert0524-B Midget bottle0525 Midget 90º connectors0526 Midget 180º connectors0527 Pinch clamp0528 28/12 to 12/5 Socket adapter

0523

0523

I

0524

0524

I

0524

B

0528

0526

0527

0525

Page 43: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 6Method 6Method 6

Method 6Method 6Method 6

Method 6Method 6Method 6

1-381-381-38

Midget Impinger Set

Method 6 Heated Sampling Probe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

# 050012 The Midget Impinger Set IncludesQty Part Number Item1 0524I Midget Ball-Joint O-ring Insert (Std.)3 0523I Midget Ball-Joint O-ring Insert (Mod.)1 0525 Midget 90’ Connectors3 0526 Midget 180’ Connectors8 0527 Midget 12/5 Pinch Clamps4 0524B Midget Impinger Bottle11 0507 Ball joint screw clamps

The Midget Glassware Set includes all components for Method 6, 26, and more. *Filter sold separately

12/5 Ball Joint With O-Ring ConnectionItem Part Number

Pyrex Quartz 316 Stainless Steel2’ Probe 0102-6-BP 0102-6-BQ 0102-6-BS3’ Probe 0103-6-BP 0103-6-BQ 0103-6-BS4’ Probe 0104-6-BP 0104-6-BQ 0104-6-BS5’ Probe 0105-6-BP 0105-6-BQ 0105-6-BS6’ Probe 0106-6-BP 0106-6-BQ 0106-6-BS

1” stainless steel outer sheath with internal heating element liner and type-K probe thermocouple. Probe liners are available in 316 stainless steel, quartz and Pyrex. Also available in 220V confi guration.

Page 44: Clean Air Catalog

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8 SOURCE SAMPLING EQUIPMENT

1-391-391-39Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

® The Controlled Condensation System consist of:

Qty Part Number SO3 Probes and Liners

1 Probe1 LinerSpare Liners Recommended

0514P 4 ft. Stainless Steel Heated Probe (600 °F) with 4 ft. Quartz Liner0516P 6 ft. Stainless Steel Heated Probe (600 °F) with 6 ft. Quartz Liner0518P 8 ft. Stainless Steel Heated Probe (600 °F) with 8 ft. Quartz Liner05164 4 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner05161 6 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner

051618 8 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner05501 4 ft. Quartz Glass Probe Liner 18/9 Ball Joint05502 6 ft. Quartz Glass Probe Liner 18/9 Ball Joint05507 8 ft. Quartz Glass Probe Liner 18/9 Ball Joint

Qty Part Number SO3 Sample Train Glassware and Connectors1 05504 Quartz 90° Connector 18/9 Ball & Socket Joint1 05503 Quartz Glass Filter Holder 18/9 Ball & Socket Joint

1 Water Bath1 Condenser Tube

05162 Temperature Regulated Water Bath (150 °F) with Quartz Glass Condenser Tube05162A Temperature Regulated Water Bath (150 °F) No Condenser Tube05505 Quartz Glass Condenser Tube 18/9 Socket Joint

2 05503S Filter Holder Springs1 0618Q 37 mm Quartz Filter Media 100/pk3 050718 18/9 Glassware Clamps1 9905 Quartz Glass Wool1 05503P 18/9 Ball Joint Plug (for leak checking)1 05503HB 18/9 Ball Joint to ¼” Hose Barb1 05503PMP Purge Pump1 0419T 1/2”x3/8” Tefl on® Reducing Union

10 ft. 0769375 3/8” Tefl on Tubing1 05503IB 28/12 Socket to ¼” Hose Barb4 05750 Impinger with Modifi ed Stem (straight)4 0505 180° Connector 28/12 Socket

Qty Part Number SO3 Hardware1 051621 SO3 Heated Filter Box (550 °F) 1 0725RNT Universal Temperature Controller 1 0028 Method 5 Control Console and Pump1 0033 4 Impinger Compartment1 0034 28/12 Impinger Outlet

1051615QC 15 ft. SO3 Electrical Umbilical051650QC 50 ft. SO3 Electrical Umbilical

1051515 15 ft. SO3 Sample Umbilical051550 50 ft. SO3 Sample Umbilical

Page 45: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 8Method 8Method 8

Method 8Method 8Method 8

Method 8Method 8Method 8

1-401-401-40

8A & SO3 Controlled Condensation System Diagram

VAC UUM

PRESSURE

8888 PRO BE

A

XU

PUMP

LO O SEN

P

VACUUM

UM

P

1STACK O UTLETPRO BE

2FI LTER

3 4

I MP.AUXI LI ARY

5

FI LTER8888

PO WER

8888

PUMP VALVES + LEAK CHECK

2

-

+

PITOT

I NLETSAM PLE

I .G.S.

1

F LOW CONTROL

O PEN

COARSE

CLO SE

F INE

543

67

1098

8888

Universal Temperature

Controller

8888

Sample UmbilicalSO3

4 Impinger Compartment

Modified Impinger

Glass Wool

Water Bath

Sampling Train

SO

3SO

Method 5 Control Console

Electical Umbilical

LinerSO3

ProbeSO3

18/9 Ball Plug

90 Deg. Connector

SO

18/9 Ball & Socket

37mm Filter Holder3

Filter Spring

3

18/9 Glassware Clamp

37mm Filter Media

Heated Filter Box3SO

SO

Purge Pump

Impinger outlet28/12

3/8" Teflon Tube

28/12 Sockes to 1/4" Hose Barb

180 Deg. Connector

28/12

18/9 Ball to 1/4" Hose Barb

Condenser Tube

1/2" x 3/8" Teflon Reducing Union

3SO

3

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 46: Clean Air Catalog

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8Me

thod 8

Metho

d 8 SOURCE SAMPLING EQUIPMENT

1-411-411-41

8A & SO3 Heated Filter Box

8A & SO3 Probes and Liners

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number SO3 Probes and Liners0514P 4 ft. Stainless Steel Heated Probe (600 °F) with 4 ft. Quartz Liner0516P 6 ft. Stainless Steel Heated Probe (600 °F) with 6 ft. Quartz Liner0518P 8 ft. Stainless Steel Heated Probe (600 °F) with 8 ft. Quartz Liner05164 4 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner05161 6 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner

051618 8 ft. Stainless Steel Heated Probe (600 °F) with Cable Heater, No Liner05501 4 ft. Quartz Glass Probe Liner 18/9 Ball Joint05502 6 ft. Quartz Glass Probe Liner 18/9 Ball Joint05507 8 ft. Quartz Glass Probe Liner 18/9 Ball Joint

SO3 Probe Includes:• Type K probe liner thermocouple with standard male plug• Type K stack thermocouple with standard male plug• Stainless Steel Sheath*Power Requirement: 120V AC or 220V confi gurations are available.

Part Number Item051621 SO3 Heated Filter Box (550 °F)

The Clean Air Express SO3 Controlled Condensation System is de-signed to allow the separation of H2SO4 from SO2 by cooling the gas stream below the dew point of H2SO4 but above the H2O dew point. Applicable for method 8A Determination of Sulfuric Acid Vapor or Mist (including Sulfur Trioxide) and Sulfur Dioxide Emissions from Kraft Recovery Furnaces. The condenser utilizes a straight quartz tube fi lled with quartz wool surrounded by a temperature regulated water bath. No recirculation pump or external water heaters are re-quired. The system works in conjunction with standard Method 5 Iso-kinetic Control Consoles and Heater Controllers. Temperature Regu-lator Water Bath sold seperately.

Page 47: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 8Method 8Method 8

Method 8Method 8Method 8

Method 8Method 8Method 8

1-421-421-42

8A & SO3 Sample Train Glassware and Connectors

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number SO3 Sample Train Glassware and Connectors05504 Quartz 90° Connector 18/9 Ball & Socket Joint05503 Quartz Glass Filter Holder 18/9 Ball & Socket Joint05162 Temperature Regulated Water Bath (150 °F) with Quartz Glass Condenser Tube

05162A Temperature Regulated Water Bath (150 °F) No Condenser Tube (not shown)05505 Quartz Glass Condenser Tube 18/9 Socket Joint

05503S Filter Holder Springs0618Q 37 mm Quartz Filter Media 100/pk (not shown)050718 18/9 Glassware Clamps9905 Quartz Glass Wool

05503P 18/9 Ball Joint Plug (for leak checking) 05503HB 18/9 Ball Joint to ¼” Hose Barb

05503PMP Purge Pump (not shown)0419T 1/2”x3/8” Tefl on® Reducing Union

0769375 3/8” Tefl on® Tubing (not shown)05503IB 28/12 Socket to ¼” Hose Barb05750 Impinger with Modifi ed Stem (straight)0505 180° Connector 28/12 Socket

0516

2

0550405

750

0550

5

05503IB

0419T05503HB05503P9905

05071805503S05503

0505

Page 48: Clean Air Catalog

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

Metho

d 17

SOURCE SAMPLING EQUIPMENT

1-431-431-43

Method 17 Probes with Removable Liner

Nozzles, Filter Holders and Associated Items

Method 17 Umbilical Cables

Method 17 Probes

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Description036125 25’ Method 17 Umbilical Cable036150 25’ Method 17 Umbilical Cable036175 25’ Method 17 Umbilical Cable0361100 25’ Method 17 Umbilical Cable

*Add QC to end of part number for Stainless Steel Quick connects

Part Number Item Part Number Item0102-17 2’ Stainless Steel M-17 Probe 0108-17 8’ Stainless Steel M-17 Probe0103-17 3’ Stainless Steel M-17 Probe 0109-17 9’ Stainless Steel M-17 Probe0104-17 4’ Stainless Steel M-17 Probe 0110-17 10’ Stainless Steel M-17 Probe0105-17 5’ Stainless Steel M-17 Probe 0111-17 11’ Stainless Steel M-17 Probe0106-17 6’ Stainless Steel M-17 Probe 0112-17 12’ Stainless Steel M-17 Probe0107-17 7’ Stainless Steel M-17 Probe

Clean Air Express Method 17 probes feature Stainless Steel Construction, Sample Drier, Calibrated “S” Type Pitot and Type “K” Probe and Stack Thermocouple.

Part Number Item Part Number Item0594 30x100 Alundum Filter Holder 0400NS Stainless Steel Nozzle Set0595 30x100 Alundum Thimble O500317 M-17 Glassware Set0596 Shepherd Hook 0500 Knock –Out Jar set0561 47 mm Filter Holder

Part # Item Part # Item Part # Item1172H 2’ Heated M-17 Probe 11710H 10’ Heated M-17 Probe 1177 7’ Unheated M-17 Probe1173H 3’ Heated M-17 Probe 11711H 11’ Heated M-17 Probe 1178 8’ Unheated M-17 Probe1174H 4’ Heated M-17 Probe 11712H 12’ Heated M-17 Probe 1179 9’ Unheated M-17 Probe1175H 5’ Heated M-17 Probe 1172 2’ Unheated M-17 Probe 11710 10’ Unheated M-17 Probe1176H 6’ Heated M-17 Probe 1173 3’ Unheated M-17 Probe 11711 11’ Unheated M-17 Probe1177H 7’ Heated M-17 Probe 1174 4’ Unheated M-17 Probe 11712 12’ Unheated M-17 Probe1178H 8’ Heated M-17 Probe 1175 5’ Unheated M-17 Probe1179H 9’ Heated M-17 Probe 1176 6’ Unheated M-17 Probe

Clean Air Express Method 17 Probes feature Stainless Steel construction, Silicone Heating Element, Calibrated “S” Type Pitot, Stainless Steel Probe Liner, Stainless Steel Union and Type “K” Probe and Stack Thermocouples.*Standard lengths available up to 20’ call your CleanAir representative for price and availability

Clean Air Express Method 17 Um-bilical Cables feature highly fl exible 3/8” ID Gum Rubber Tubing, PVC Pitot Lines, 2 Type “K” Thermocou-ple Extension Wires with Standard Plugs

Clean Air Express carries an extensive line of sampling accessories to help complete your projects. Our large inventory allows us to ship any of these items overnight to your testing location.

Page 49: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 17Method 17Method 17

Method 17Method 17Method 17

Method 17Method 17Method 17

1-441-441-44

Method 17 Sampling Train Diagram

-

250

250

8888

250

Impinger Outlet 28 \12#0034

180 Deg. Connector 28/12#0505

4 Impinger Compartment#0033

Modified Impinger Assembly#05750

Method 17 Umbilical Cable

Method 17 Umbilical Cable Extension

Socket to Hose BarbConnector 28 \12

#0508

Isokinetic Control Console#0028

47 mm SS In-Line Filter Holder#0561

30 mm x 100 mm SS Thimble Holder#0594

SS Nozzle Unheated Method 17 Probe

Offset Type S Pitot Tube

SS Shepards Hook (For vertical Sampling)*0104S17

Standard Type S Pitot Tube

Knock Out Jars #(Alternate M17 Glassware)

Method 17 Sampling Train

Rubber Stopper#0611#0611

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 50: Clean Air Catalog

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

Metho

d 23

SOURCE SAMPLING EQUIPMENT Method 23 Sampling Train Method 23 Sampling Train

1-451-451-45Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

The Clean Air Method 23 Train is suited to perform test-ing for Polychlorinated Dibenzo-P-Dioxins and Polychlo-rinated Dibenzofurans from Stationary Sources. Other pollutants can be collected in the impinger portion of the system providing the proper reagent is utilized.

Part Number 0100-23

Part Number Item0028 Isokinetic Control Console with Pump0032 Sample Oven Compartment0030 Impinger Compartment

050023S Method 23 Glassware Set Ball Joint or Ball Joint O-Ring0034 Stainless Steel Impinger Outlet

036050QC 50’ Umbilical Cable with Stainless Steel Quick Connects0106BP 6’ Stainless Steel Heated Method 5 Probe with Glass Liner and Geometric Calibration Report

0140 Stainless Steel Probe Port Adaptor Seal Assembly0400NP Complete Set of Borosilicate Nozzles (1/8”, 3/16”, 1/4", 5/16”, 3/8”, and 1/2") with nuts and ferrules

0158 Sample Recovery Kit0621 8.5cm Glass Fiber Filters (Box of 100)9900 Recirculation Pump 120V (Submersible)

• Power Requirement: 120V and 220V confi gurations in stock• Thermocouple connections: Type K• Cabinets: Welded Aluminum Detachable/Stackable Meter and Pump• Temperature Controllers: Solid State with 6 Channel Selector• *Method 23 Train Components Also Sold Separately

Page 51: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 23Method 23Method 23

Method 23Method 23Method 23

Method 23Method 23Method 23

Method 23 Sampling Train Diagram

1-461-461-46

Isokinetic Control Consol#0028

Method 23 Sampling Train

Recirculation Pump#9900

Stack Wall

Cyclone Bypass 28\12#0504

M5 Sample Oven#0032

Port Seal Adapter#0140

M5 Probe, Liner and Nozzle

3" M5 Filter Assembly28\12 #0509BTFE

Monorail Support

Modified Impinger Assembly#05750

8 Impinger Compartment#0030

Standard Impinger Assembly(Greenburg Smith) #05755

MM-5 Hybrid Bottle28/12 #05682

UX

A P

MU

P

250

250

250

Method 5 Umbilical

8888

3

12

89

10

76

45

F LOW CONT ROL

V ACUUM

+

-

CO ARSE

FI NE

"S" Connector28/12 #0532B

180 Deg.Connector28\12 #0505

Impinger Outlet 28\12#0034

Sorbent Trap 28/12 #0517B

Coil Condense28/12 #0516B

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 52: Clean Air Catalog

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

Metho

d 29

SOURCE SAMPLING EQUIPMENT Method 29 Sampling Train Method 29 Sampling Train

1-471-471-47Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

The Clean Air Method 29 Train is suited to perform test-ing for Metals Emissions from Stationary Sources. Other pollutants can be collected in the impinger portion of the system providing the proper reagent is utilized.

Part Number 0100-29

Part Number Item0028 Isokinetic Control Console with Pump0032 Sample Oven Compartment0030 Impinger Compartment

050029 or 050029M Method 29 Glassware Set Ball Joint or Ball Joint O-Ring (050029M = Mercury Metals Glassware Set)

0034 Stainless Steel Impinger Outlet036050QC 50’ Umbilical Cable with Stainless Steel Quick Connects

0106BP 6’ Stainless Steel Heated Method 5 Probe with Glass Liner and Geometric Calibration Report0140 Stainless Steel Probe Port Adaptor Seal Assembly

0400NP Complete Set of Borosilicate Nozzles (1/8”, 3/16”, 1/4", 5/16”, 3/8”, and 1/2") with nuts and ferrules 0158 Sample Recovery Kit0621 8.5cm Glass Fiber Filters (Box of 100)

*Tapered or Barrel style liners and nozzles are stock items• Power Requirement: 120V and 220V confi gurations in stock• Thermocouple connections: Type K• Cabinets: Welded Aluminum Detachable/Stackable Meter and Pump• Temperature Controllers: Solid State with 6 Channel Selector

Page 53: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 29Method 29Method 29

Method 29Method 29Method 29

Method 29Method 29Method 29

Method 29 Sampling Train Diagram

1-481-481-48

Standard Impinger Assembly(Greenburg Smith) #05755

Isokinetic Control Consol#0028

Method 29 Sampling Train

(Optional) Short Stem Impinger Assembly

28/12 #05507S

3" M5 Filter Assembly28\12 #0509BTFE

Cyclone Bypass 28\12#0504

M5 Sample Oven#0032

Port Seal Adapter#0140

M5 Probe, Liner and Nozzle

Stack Wall

Monorail Support

8 Impinger Compartment#0030

Modified Impinger Assembly#05750

UX

A

250

250

250

8888

F LOW CONT ROL

V ACUUMP

MU

P

+

-

CO ARSE

FI NE

1

8

32

76

45

910

Method 5 Umbilical

180 Deg.Connector28\12 #0505

Double "L" Connector28/12 #0506L

Impinger Outlet 28\12#0034

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 54: Clean Air Catalog

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

SOURCE SAMPLING EQUIPMENT Method 30B Sample Console with Digital Display

1-491-491-49

SK25 Dry Gas Meter

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The purpose of Method 30B is to measure total vapor phase mer-cury (Hg) emissions from coal fi red sources. Knowledge of Meth-ods 1, 4, and 5 is recommended. The testing should be done after the stack gas has passed through all pollution control devices, i.e. with a stream that is low in particulates. Method 30B is used to test the accuracy of current vapor phase Hg constant emissions monitoring systems (CEMS) and can also be used to test for the compliance of mercury emissions standards. The method requires a minimum of two simultaneous sampling trains.

Part Number 1030

Specifi cations• Sample Pump: Internal Diaphragm Vacuum Pump• Dry Gas Meter: S-275 L/rev. • Rotometer: Dual Float Glass - 1.24 lpm and 2.54 lpm• Timer: Digital LCD w/ Battery Backup (Displays h, m, s)• Umbilical Power Input Connection: Amphenol 4-pin• Auxiliary Power Output Connection: 3 pin 120 V receptacle• Circuit Protection: Panel Mounted Circuit Breaker Switches• Sample Inlet Connection: 1/4” Stainless Steel Quick-Connects• Temperature Controllers: Solid State for Probe & Filter• Temperature Monitor: LED readout w/ Four-Position Switch• Thermal Couple Connection: K-Type Miniature Panel Mount• Cabinet: 0.095” Welded Aluminum w/ Quick-Release Access

Doors• External Dimensions (h x w x d): 14” x 14” x 11” (356 mm x

356 mm x 279 mm)• Weight: 30 lbs. (13.6 kg)

Part Number Item9822 SK25 Dry Gas Meter

SK25 dry gas meters are available for use in many of today’s systems. The SK25 dry gas meter is used in Method 30B control console. Clean Air Express can also rebuild and calibrate your present meter control console.

Page 55: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 30BMethod 30BMethod 30B

Method 30BMethod 30BMethod 30B

Method 30BMethod 30BMethod 30B

Method 30B Heated Probe Train Diagram

1-501-501-50

Method 30B Unheated Probe Train Diagram

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 56: Clean Air Catalog

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

SOURCE SAMPLING EQUIPMENT Method 30B Sample Gas Conditioner Method 30B Sample Gas Conditioner

1-511-511-51

MET 30B Probe MET 30B Probe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The purpose of Method 30B is to measure total vapor phase mercury (Hg) emissions from coal fi red sources. Knowledge of Methods 1, 4, and 5 is recommended. The testing should be done after the stack gas has passed through all pollution control devices, i.e. with a stream that is low in particulates. Method 30B is used to test the accuracy of current vapor phase Hg constant emissions monitoring systems (CEMS) and can also be used to test for the compliance of mercury emissions standards. The method requires a minimum of two simultaneous sampling trains.

Part Number 1030GC

Specifi cations• Sample Inlet Connection: 1/4” Male Stainless Steel

Quick Connect with Stainless Steel Valves• Sample Outlet Connection: 1/4” Female Stainless Steel

Quick Connect with Stainless Steel Valves• Gas Conditioner : 115V 60 Hz 2 Pass• Cabinets: Welded Aluminum• Quick-Release: Access Doors• External Dimensions (h x w x d): 17.5” x 12” x 18.5 “• Weight: 37 lbs. (17 kg)

Part Number Item1030PS MET 30B Probe (6’, 8’, or 10’)

10304HH MET 30 Heated Quad Head10304UH MET 30 Unheated Quad Head

Clean Air Express Method 30B Heated Sampling Probes feature a unique sheathed design that allows quick and easy replacement of sorbent traps, stack thermocouple, and heated and unheated sample line connections.

* 10 mm and 6 mm Traps Available

Page 57: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 30BMethod 30BMethod 30B

Method 30BMethod 30BMethod 30B

Method 30BMethod 30BMethod 30B

Method 30B Umbilical Extension

Method 30B Impinger/Condenser Assembly

Method 30B Calibration Kit

Method 30B Data Logger

Method 30B Heated and Unheated Umbilical/Probe Assembly

1-521-521-52Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item1030UE10A Umbilical Extension 10’ Blue/Green1030UE10B Umbilical Extension 10’ Red/Yellow

Clean Air Express Method 30B umbilical extensions are constructed of three (3) type-K thermocouple lines and two (2) tefl on lines (with quick connects) all wrapped in a durable fl exible nylon mesh mate-rial.

Part Number Item1030DL Method 30B Data Logger

Clean Air Express Method 30B calibration kit includes three orifi ce sets with fi ttings, hardware and case. The orifi ces range from 0.5 liters to 1.0 liters to 2.0 liters.

Part Number Item050030 Impinger/Condenser Assembly

Part Number Item1030CK Method 30B Calibration Kit

Part Number Item1030U25 25’ Unheated Umbilical/Probe

980183030B 25’ Heated Hose/Probe

Page 58: Clean Air Catalog

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

Metho

d 30B

SOURCE SAMPLING EQUIPMENT Method 30B Sorbent Traps Method 30B Sorbent Traps

1-531-531-53Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

RATA Short-term Traps, 6mm GlassDescription Size: O.D. x L (mm) Sections Sorbent/Section Ends Spike (ng) Cat. No.

RATA Vapor-spiked Iodin-ated Charcoal Traps 6 x 200 2 200 mg GO

• 50• 100• 150• 200

• 226-215• 226-216• 226-217• 226-218

Rata Unspiked Iodinated Charcoal Traps 6 x 200 2 200 mg GO None • 226-219

RATA Short-term Traps, 10 mm Glass

Description Size: O.D. x L (mm) Sections Sorbent per Section Ends Spike (ng) Cat. No.

RATA Vapor-spiked Iodin-ated Charcoal Traps 10 x 240 2 300 mg GO

• 50• 100• 150• 200

• 226-235• 226-236• 226-237• 226-238

Rata Unspiked Iodinated Charcoal Traps 10 x 240 2 300 mg GO None • 226-239

Unspiked Long-term Traps for Quantifi cation of Stack Emissions

Description Size: O.D. x L (mm) Sections Sorbent per Section Ends Spike (ng) Cat. No.

Unspiked Iodinated Char-coal Traps for Quantifi cation of stack emissions prior to Appendix K sampling

10 x 240 2 200 mg GO None • 226-223

Appendix K Long-term Compliance Traps

Description Size: O.D. x L (mm) Sections Sorbent per Section Ends Spike (ng) Cat. No.

Appendix K vapor-spiked Iodinated Charcoal Traps

Custom Spiking Avail-able!

10 x 240 3 0.5 gm GO

• 1,000• 2,500• 5,000• 7,500• 10,000• 15,000• 20,000• 25,000• 30,000• 40,000

• 226-224• 226-225• 226-220• 226-226• 226-227• 226-221• 226-228• 226-229• 226-222• 226-230

Page 59: Clean Air Catalog

SOURCE SAMPLING EQUIPMENTMethod 201AMethod 201AMethod 201A

Method 201AMethod 201AMethod 201A

Method 201AMethod 201AMethod 201A

PM10 Cyclone Package

1-541-541-54Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item0040-K PM10 cyclone package0040 PM10 cyclone

0040-NS Isokinetic nozzle set (11)0561 47 mm Stainless Steel Filter Holder

The PM10 cyclone is built to meet EPA specifi cations for method 201A testing, and is designed for in-stack measurement of particulate matter equal to or less than 10µm. Designed by experienced fi eld testers, its heavy-duty construction can sustain rigorous use. For greater adaptability with various stack sampling equipment, the shank locks down with any 5/8” compression fi tting. The PM10 cyclone kit includes: PM10 cyclone, eleven (11) nozzles, fl at wrenches and anti-seize lubricant; all en-cased in a lifetime warranty shipping case.

Page 60: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

2-12-12-1Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

Clean Air Engineering Express designs and manufactures a variety of gas sampling sys-tems and CEM accessories. These include integrated gas conditioning systems, extractive and dilution fl ow panels and custom gas extrac-tion probes, designed for rugged service and high reliability.

We specialize in solving diffi cult gas sampling problems for a variety of industries. Call us To-day.

07202

0036

0517SS

Page 61: Clean Air Catalog

CEM EquipmentCEM EquipmentCEM Equipment

2-22-22-2

CONTINUOUS EMISSIONS MONITORING

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

PageNOX Analyzers ...................................................... 2-3 ECO Physics NOX Analyzer................................. 2-3CEM Probes .......................................................... 2-4 JCT Heated Filter Probe ..................................... 2-4 CEM Heated Filter Probe .................................... 2-5 Heated CEM Probes ........................................... 2-6CEM Equipment ................................................... 2-7 Cateco CEM Heated Filter Unit ........................... 2-7 Large Cateco CEM Heated Filter Unit ................ 2-8RATA & CEM Equipment ...................................... 2-8 CEM Heated 3 Point Probe ................................. 2-8 Heated Sample Line ........................................... 2-9Temperature Controllers ..................................... 2-10 Universal Temperature Controller ....................... 2-10 Multiple Zone Temperature Controller ................. 2-10 Rack Mount Temperature Controller ................... 2-10Sample Gas Conditioners ................................. 2-11 MAK 10 Gas Conditioner .................................. 2-11 SGC4000 Gas Conditioner ............................... 2-12 Stainless Steel Coil Condenser ........................ 2-12CEM Control Panels ........................................... 2-13 Dilution Control Panel ....................................... 2-13 FLW6 Flow Panel .............................................. 2-13 5 Channel Calibrator ......................................... 2-14 Sample Gas Distribution Module ...................... 2-14

CEM EQUIPMENT

®

0724

0725RNT

Page 62: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING Eco Physics NOx Analyzers Eco Physics NOx Analyzers

2-32-32-3Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

No matter where and at what concentrations nitrogen oxides have to be detected, you can depend on ECO PHYSICS analyzers to handle the job quickly, reliably and with precision that is unmatched anywhere in the world. Whether at trace levels in a clean room environment or for the analysis of exhaust gases directly at the source, you will fi nd the type of che-miluminescence detector (CLD) to perfectly suit you.

*Each and every CLD NOx analyzer must pass an extensive test procedure before it leaves the factory. Test procedures and test equipment comply with ISO 9001 standards and are documented in accordance with international regulations. Call Clean Air Express for detailed product data sheets for any ECO PHYSICS analyzer.

Model Range Feature Component(s)70S 0-5,000 ppm Large Range NOx (NO)70E 0-500 ppm High Sensitivity NOx (NO)82S 0-5,000 ppm 0.2 ppm, compact NOx (NO)84S 0-500 ppm 0.02 ppm, compact822S 0-5,000 ppm 2 Channel Compact NO, NO2, NOx

824MMd 0-5,000 ppm & 0-500 ppm Dual Sample Inlets NO, NO, NOx, NOx844CMh 0-500 ppm NH3, Heated Head NOx, NH3, Noxamin700EL 0-10,000 ppm 2 Channel Analyzer NO, NO2, NOx

700ELHT 0-10,000 ppm Heated Tubing NO, NO2, NOx700LEVHT 0-500 ppm Low Noise NO, NO2, NOx

88SP 0-5 ppm With Flow Measurement NO86NOP 0-50 ppm Low Level Ambient NO700AL 0-100 ppm Measures to 1 ppb NO, NO2, NOx88NOP 0-5 ppm Low Level Ambient NO88CYP 0-5 ppm Ambient Ammonia NOx, NH3, total NOx-aminesPLC860 0-5,000 ppb Photolytic Converter NO2780TR Limit 10 ppt Atmospheric Research NO, NOy790SR Limit 1 ppt Atmospheric Research NO, NO, (Noy)

Page 63: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

Jct Heated Filter Probe

2-42-42-4Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

The JES 300 series heated gas sample probes are designed for continuous use with extractive sampling systems—even where the sample contains dust, aerosols, water vapor and corrosive gases and in situations where the gas must be kept free of contaminants prior to hot analysis or sample conditioning. The JES 300 incorporates a non-corrosive heated, replaceable ceramic fi lter element with a fi lter porosity of 2 microns. The fi lter is mounted in an electrically heated, stain-less steel housing. The fi lter housing is thermally insulated and enclosed in a weatherproof case. The JES 300 uses a microprocessor-based temperature controller. The temperature controller is user-selectable from 32° F to 375° F.

Part Number Item0730J Heated Filter Probe

0730FE Replacement 2 micron Silicone-Carbide fi lter element

JES 300 Filter Probe includes: • Filter Probe Assembly• Thermal-insulated enclosure with

temperature controller• 2” FPT Mount

Power Requirement: 115VAC/60Hz, Weight: 25 lbs

Page 64: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING CEM Heated Filter Probe CEM Heated Filter Probe

2-52-52-5

SAMPLEOUTPOWER

CAL

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item07202 2’ Effective CEM Heated Filter Probe with 20-micron SS Frit, Fiber Filter stem07204 4’ Effective CEM Heated Filter Probe with 20-micron SS Frit, Fiber Filter stem07206 6’ Effective CEM Heated Filter Probe with 20-micron SS Frit, Fiber Filter stem07208 8’ Effective CEM Heated Filter Probe with 20-micron SS Frit, Fiber Filter stem07275 In-Line Self-Regulating (275 °F) Temperature Control

The Clean Air Express CEM Heated Filter Probe has an integral fi lter chamber that will accept a glass fi ber fi lter cartridge or a stainless steel sintered frit. Two stages of fi ltration may be achieved by using an in-stack course 20-micron SS frit on the probe end and a fi ne .02-micron fi lter in the chamber. The probe and fi lter chamber are heated by the same reliable high temperature cable heater eliminating the need for multiple temperature controllers. An optional in-line self-regulating (275 °F) temperature control may be incorporated into the power cord making the heated fi lter probe totally self contained and easy to use.

• Max Temp: (w/SS frit 750 °F) (w/Inconel frit 1100 °F)• Voltage: 120/240 Vac

Page 65: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

Heated Gas Sample Probes with Attached Frit

2-62-62-6

Heated Gas Sample Probes

Unheated Gas Sample Probes with Attached Frit

Unheated Gas Sample Probes

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 07416

Part Number 07396

Part Number 07406F

Part Number 07406

Specifi cations• Length: 2ft - 10ft • Voltage Requirement: 120V/240V• Power Requirement: 100-800W Depending on length • Power Connection: Male Receptacle• Thermocouple Connection: Type-K

Specifi cations• Length: 2ft - 10ft • Voltage Requirement: 120V/240V• Power Requirement: 100-800W Depending on length • Power Connection: Male Receptacle• Thermocouple Connection: Type-K

Specifi cations• Length: 2ft -10ft• Construction: 304 or 316 Stainless Steel• Tubing: 3/8” OD. • Calibration Tee: 3/8”

Specifi cations• Length: 2 ft -10ft• Construction: 304 or 316 Stainless Steel• Tubing: 3/8” OD. • Calibration Tee: 3/8”

The Single Point Heated CEM Probe is available with a 1/4” or 3/8” stainless steel heated liner with a 1” O.D. protective stainless steel sheath and type K thermocouple. The probe comes in various lengths and can handle temperatures up to 400 °F (1200 °F with optional high temperature heater). 120v and 220v available. Add HT to end of part number for high temperature option.

Page 66: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING CEM Cateco Assembly CEM Cateco Assembly

2-72-72-7

CEM Cateco Control Umbilical CEM Cateco Control Umbilical

CEM Cateco Heated Filter Unit CEM Cateco Heated Filter Unit

Dual Heater Controller Dual Heater Controller

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 0035A

Specifi cations• Umbilical Power Input Connection: Amphenol 4-pin Female/Male• Auxiliary Power Output Connection: 3 pin 120V receptacle• Thermocouple Connection: K-Type Plug (0316M x 3 0316F x 1)• Length: 2 Feet• Weight: 1 lbs. (0.45 kg)

Specifi cations• Voltage Requirement: 120V• Umbilical Connection: Amphenol 4-pin (9418)• Temperature Controllers: 1/32 DIN, Fuzzy Logic (91301)• Thermocouple Connection: K-Type panel mount (0316-SM)• External Dimensions (h x w x d): 3.15” x 4.76” x 7.75”• Weight: 3 lbs. (1.36 kg)

Part Number 0035C

Specifi cations• Voltage Requirement: 120V• Power Requirement: 300W• Umbilical Power Input Connection: Amphenol 4-pin (9412)• Auxiliary Power Output Connection: 3 pin 120V receptacle• Thermocouple Connection: K-Type panel mount (0316-SM)• External Dimensions (h x w x d): 7.5” x 9.25” x 6.25”• Internal Dimensions (h x w x d): 6.25” x 7.25” x 7.25”• Weight: 7 lbs. (3.2 kg)

CEM Cateco Assembly Includes:• 0035A - Cateco CEM Control Umbilical• 0035B - Cateco CEM Heated Filter Unit• 0035C - Dual Heater Controller

Part Number 0035B

Part Number 0035RNT

Page 67: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

Large CEM Cateco Assembly

2-82-82-8

CEM Heated 3 Point Probe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The 3 Point Probe makes CFR Part 60 & Part 75 RATA sampling as easy as 1,2,3. The electrically actuated stainless steel ball valve allows 1 of 3 user defi ned traverse points to be sampled. A calibration gas tee is included on point1. Sample points 1, 2, or 3 can be selected manually at the probe (Local Mode) or from remote dry contacts or data logger (Remote Mode). Built in digital controllers maintain oven and probe at desired temperature. 3 stainless steel fritted fi lters on the probe and 3 glass fi ber fi lters in the oven keep the sample clean. A strain relief is provided for a steady heated sample line connection.

Specifi cations• Voltage Requirements: 120 VAC• Power Requirement: 5.1 Amps (full load)• Circuit Protection: 15 Amp Breaker• Control Umbilical Connection: 6-pin Amphenol• Ball Valve: 316 Stainless Steel, 5 Way• Oven Filters: 3 x 304 Stainless Steel Filter Holder • Probe Filters: 3 x 316 Stainless Steel Frit• Probe: 24” x 2” Dia. 304 Stainless Steel• Probe Length Adjustment: Add Desired Length of 3/8”• Stainless Steel Tubing to Each Point• Oven Internal Dimensions (h x w x d): 9 ¼” x 8 ½” x 8 ¾”• Weight: 34 lbs.

Specifi cations• Voltage Requirement: 120V• Power Requirement: 300W• Umbilical Power Input Connection: Amphenol 4-pin (9412)• Auxiliary Power Output Connection: 3 pin 120V receptacle• Thermocouple Connection: K-Type panel mount (0316-SM)• External Dimensions (h x w x d): 9.5” x 10.5” x 9.5”• Internal Dimensions (h x w x d): 8.25” x 9.25” x 8.75”• Weight: 12 lbs. (5.4 kg)

Part Number 0036

Part Number 073123

The double-wall aluminum constructed heated fi lter unit is an excellent choice for CEM applications that require heated fi lters or valves. The case is extremely lightweight and durable, and heats quickly with its small heating area. The probe is mounted through an aluminum arm identical to those used on the Modular Sample Unit. A strain relief is provided for a stable heated sample line connection. Electrical connections are compatible with those used in the industry. An optional quick mount dual heater controller (# 0035C) is available to control probe and box heaters.

Part Number Item0035LC Large CEM Cateco Heated Filter Unit

Page 68: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING Heated Sample Line Heated Sample Line

2-92-92-9

Self Regulating Heavy Duty Heated Sample Line Self Regulating Heavy Duty Heated Sample Line

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

*Custom lengths, voltage, and confi guration availablePart Number Voltage Watts Length/FT

0723-10 120 300 100723-25 120 750 250723-50 120 1500 50

0723-100 120 2500 100*0723-100HD 120 3000 100

0725RNT Universal Temperature Controller*HD series offers 3000w and triple insulation. Manufactured to have a continuous operating temperature of 400°F at -20°F ambient temperature.

These fl exible lines feature an electrically heat traced and insu-lated 3/8” Tefl on® sample line with a stainless steel over braid and stainless steel tube ends, a ¼” Tefl on® calibration line, 3 pin Amphenol power connector, and 2 type K thermocouples. Pro-tected by a durable scuff resistant extruded polyurethane jacket. *Temperature controller optional.

Clean Air Engineering heavy duty heated sample lines consist of heat traced Tefl on® with insulation and nylon braid. Industrial Strength heated sample lines consist of heat traced Tefl on® with insulation, nylon braid and silicone jacket. Sample lines are con-structed of heavy wall (.0625”) PTFE outside diameters. Termi-nations and standard thermocouple are included. *Temperature controller optional.

Part Number Length/Ft PTFE Part Number Length/Ft PTFE072254 5’

5/8”

072252 5’

3/8”0722104 10’ 0722102 10’0722154 15’ 0722152 15’0722204 20’ 0722202 20’0722254 25’ 0722252 25’072253 5’

1/2”

072251 5’

1/4”0722103 10’ 0722101 10’0722153 15’ 0722151 15’0722203 20’ 0722201 20’0722253 25’ 0722251 25’

• Heated Sample Line - Length - Tube O.D. - Option• Example: 0722104678 (10’ 5/8” Heated Sample Line with (6) armored end, (7) strain relief & (8) thermostatic control)

Page 69: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

Universal Temperature Controller

2-102-102-10

Rack Mount Temperature Controller

Multiple Zone Temperature Controller

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 0725R

The Universal Temperature Controller is used to control heated sample lines, ovens, heated head pumps, fi lters, and probes. This Controller can be adapted to control almost any type of heating load. The standard unit features a program-mable digital temperature controller, 25 amp circuit breaker, 25 amp solid state relay output, type K thermocouple input, and a 3 pin Amphenol electrical connector housed in a compact NEMA aluminum enclosure. *Call for options on thermocouple type, voltage, and power requirements

Multiple zone temperature controllers are an excellent choice for controlling multiple instruments simultaneously such as heated sample lines, ovens, heated head pumps, fi lters, and probes. The standard unit features four programmable digital temperature controllers, four 25 amp circuit breaker switches, 25 amp solid state relays, type K thermocouples, and four receptacle outlets. Call a Sales Representative for custom confi gurations and availability.*Call for options on thermocouple type, voltage, and power requirements

The Rack Mount Temperature Controller is commonly used to control heated sample lines, ovens, heated head pumps, fi lters, and probes. This Controller can be adapted to control almost any type of heating load. The standard unit features a programmable digital temperature controller, 25 amp circuit breaker switch, 25 amp solid state relay output, type K thermo-couple input, and a 3 pin Amphenol electrical connector housed in a sub-rack mountable aluminum enclosure. *Call for options on thermocouple type, voltage, and power requirements

Specifi cations• Voltage Requirement: 120 V• Power Requirement: Up to 25 amps• Overload Protection: 25A Manual Reset Circuit Breaker• Sample Line Power Output Connection: Amphenol 3-pin• Temperature Controller: 1/32 DIN Temperature Controller• Thermocouple Connection: K-Type panel mount

Specifi cations• Voltage Requirement: 120 V• Power Requirement: Up to 25 amps• Overload Protection: 25A Manual Reset Circuit Breaker (4)• Sample Line Power Output Connection: Receptacle Outlets (4)• Temperature Controller: 1/32 DIN Temperature Controller (4)• Thermocouple Connection: K-Type panel mount (4)

Specifi cations• Voltage Requirement: 120 V• Power Requirement: Up to 25 amps• Overload Protection: 25A Manual Reset Circuit Breaker• Sample Line Power Output Connection: Amphenol 3-pin• Temperature Controller: 1/32 DIN Temperature Controller• Thermocouple Connection: K-Type panel mount

Part Number 0725PM

Part Number 0725RNT

Page 70: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING MAK 10-2 Sample Gas Conditioner MAK 10-2 Sample Gas Conditioner

2-112-112-11

MAK 10-1 Mobile Sample Gas Conditioner MAK 10-1 Mobile Sample Gas Conditioner

MAK 10-4-PS2-TF2-EC2 Sample Gas Conditioner MAK 10-4-PS2-TF2-EC2 Sample Gas Conditioner

MAK 10-4 19” Rack Sample Gas Conditioner MAK 10-4 19” Rack Sample Gas Conditioner

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

• Two gas paths• Two heat-exchangers• Two condensate pumps• One 3-pole alarm contact MAK

• Two gas paths• Two pre-seperators for Dp in > 65°• Two heat-exchangers• Four condensate pumps• One Tefl on-depth fi lters• One 3-pole alarm contact MAK• One electronic control with one 3-pole alarm contact for external moisture sensor• One fl ow meter with needle valve

• One gas path• One heat-exchangers• One condensate pump• One Tefl on-depth fi lter• One 3-pole alarm contact MAK• One electronic control with one 3-pole alarm contact for external moisture sensor• One fl ow meter with needle valve• Two handles for mobile operations

• Two gas paths• Two pre-seperators for Dp in > 65°• Two heat-exchangers• Four condensate pumps• Two Tefl on-depth fi lters• One 3-pole alarm contact MAK• Two electronic control with one 3-pole alarm contact for external moisture sensor

Page 71: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

SGC4000 Sample Gas Conditioner

2-122-122-122-122-122-12

Stainless Steel Coil Condenser

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 0517SS

Specifi cations• Material: Stainless Steel 304 or 316• Weight: 4 lbs• Dimensions: 15” x 4” x 5” The Clean Air Express Stainless Steel Coil Con-denser is made from 304 or 316 3/8” stainless steel tubing.

Part Number 0700

Specifi cations• Cooling capacity: 120 to 200 BTU/Hr @ 35 °F Plate Temperature• Cooler Plates: Hastelloy• Flow Channels: Kynar• Moisture Removal: 0 to 30% @ 5LPM• Sample Pump Flow Rate: 5LPM• Voltage: 120 VAC • Operating Temperature: 1 to 45 °C• Condensate Removal: Peristaltic Pump • Water Intrusion Monitor: Disables sample pump when moisture is detected.• Temperature Control: 1/16 DIN, Digital• Weight: 30lb.• Dimensions: 15” x 17” x 6.5”

The SGC4000 is designed to transfer sample gas to extractive analyzers for CEM and process control applications. The sample gas fl ows through a thermoelectric (Peltier cell) sample gas cooler to ensure a constant stream of dry gas is sup-plied to the analyzers.

Part Number Item0704 Cooling unit

0705S Single Power Supply0706 Temperature Controller Assembly

0707R Rebuild Kit for KNF Pump (0711R) (not shown)0710 Water Intrusion Monitor

0711R KNF Sample Pump9771-BA Double Head Peristaltic Pump

Page 72: Clean Air Catalog

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CEM

Equip

ment

CONTINUOUS EMISSIONS MONITORING Dilution Control Panel Dilution Control Panel

2-132-132-13

FLW6 Flow Panel FLW6 Flow Panel

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The #0735 Dilution Control Panel is designed to be used with the #0732D Dilution Probe for monitoring gaseous emissions with EPA reference method analyzers. The control panel features fl ow control of calibration gas and blow back air, adjust-able dilution air pressure, digital gauges and 0 - 2 vdc analog output for dilution air pressure and orifi ce vacuum. With this system, continuous in-situ sample extraction has low fl ow rates, longer fi lter life, eliminates the need for heated sample lines and transports the sample at positive pressure.

Part Number 0772

The Clean Air Express FLW6 Flow Panel is a 3RD generation 19” rack mount panel designed to control sample and cali-bration gases to extractive analyzers for CEM and process control applications. Design features include an auto mode for remotely controlling up to 13 functions from your data acquisition and control system for automated calibrations. Manual control is simplifi ed with interlocking push button switches and status outputs for fl agging data. Three calibration gas inputs (High, Mid, Low) for each channel and a separate zero gas input. Adjustable fl ow rate for probe tip calibration and sample out (A,B,C,D). Separate pressure regulators for both sample and calibration gas provide reliable calibrations by match-ing pressure and fl ow. Individual channel calibration allows other channels to stay online. Water intrusion alarm light and contact output for disabling sample pump if moisture is detected in system. Back purge function controls air and remote solenoid contacts for blowback of sample probe and fi lter.

Features• Manual Control with interlocking push buttons and 24 status outputs for

fl agging data.• Remote Control 13 Functions from your data acquisition and control sys-

tem for automated calibrations. • 4 Sample Outputs A,B,C,D with rotometers and needle valves for fl ow

control. • 13 Calibration Gas Inputs High, Medium, and Low range plus a zero gas. • Individual Channel Calibration allows other channels to stay on line.• Probe Tip Calibration with rotometers and needle valves for fl ow control. • Separate Pressure Regulators for sample and calibration gas provides

reliable calibrations.• Water Intrusion Monitor engages when moisture is detected in system. • Back purge Function allows blow back of probes and fi lters.• Internal Sample Filter for protection of fl ow panel and analyzers.• Stainless Steel Solenoids and Fittings top of the list of premium quality

parts.

Part Number 0735

Page 73: Clean Air Catalog

CONTINUOUS EMISSIONS MONITORINGCEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

CEM EquipmentCEM EquipmentCEM Equipment

5 Channel Calibrator

2-142-142-14

Sample Gas Distribution Module

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

The 5 Channel Calibrator is designed to interface CEM analyzers with fi ve individual calibration gasses. The gasses can be controlled manually or remotely to fl ow through one of two calibration ports. Sub-Rack designed for installation into a standard 19” instrument rack. Flow-meter with stainless steel needle valve provides indication and control of calibration gas fl ow rate from 1 to 10 lpm. Auto Mode allows a data acquisition system equipped with a dry contact closure to control the calibration points remotely. A 12VDC output signal is provided for use by the control system via an Amphenol connector located on the rear of the 5 Channel Calibrator.

Features• Flow meter with stainless steel needle valve provides indication and con-

trol of calibration gas fl ow rate from 1 to 10 lpm. • AUTO Mode allows a data acquisition system equipped with a dry contact

closure to control the calibration points remotely. • A 12 VDC output signal is provided for use by the control system via an• Amphenol connector located on the rear of the calibrator. Sub-Rack De-

sign for installation into a standard 19” instrument rack.

Part Number 0724

The Sample Gas Distribution Module is designed to interface CEM analyzers with four individual sample gas streams. A back pressure regulator controls the sample pressure to provide a consistent fl ow rate to the analyzers. In calibration mode the sample gas is bypassed to the vent and a calibration gas port is routed to the analyzers for internal calibration. The calibration mode can be controlled manually by front panel push button or remotely from your data acquisition system. A sample inlet fi lter is mounted on the back panel for easy access. The Sample Gas Distribution Module combined with a Calibration Module can make controlling sample and calibration gases to your analyzers as simple and easy as it can be.

Features• Flowmeters: with stainless steel needle valve provides indication and

control of sample gas fl ow rate from 0 to 1.0 lpm. and a 0-10 lpm. fl ow meter for sample vent fl ow.

• Back Pressure Regulator: provides consistent sample fl ow rates. • Sample Inlet Filter: mounted on back panel for easy access.• CAL Mode: allows a data acquisition system equipped with a dry contact

closure to• control the calibration port remotely. A status output is also provided when

in manual cal mode.• Sub-Rack Design: for installation into a standard 19” instrument rack.

Part Number 9742

Page 74: Clean Air Catalog

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

3-13-13-1Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

Clean Air Engineering Express supplies a vari-ety of portable gas analyzers to our customers. The portable analyzers are manufactured by Testo and Ecom.

We specialize in solving diffi cult gas sampling problems for a variety of industries. Call us To-day.

0880

71

33051

Page 75: Clean Air Catalog

Portable AnalyzersPortable AnalyzersPortable Analyzers

3-23-23-2

PORTABLE ANALYZERS

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

PagePortable Gas Analyzers ....................................... 3-3 ECOM-AC Plus ................................................... 3-3 Testo 350 ............................................................ 3-4 Testo 330 ............................................................ 3-5 Testo 335 ............................................................ 3-5Portable Analyzers .............................................. 3-6 Testo 880 ............................................................ 3-6

PORTABLE ANALYZERS

®

0035XL

Page 76: Clean Air Catalog

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

PORTABLE ANALYZERS ECOM-AC (Plus)

3-33-33-3Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Parameter RangeO2 0-21%CO 0-4000 ppm NO 0-4000 ppm

SO2 (option on some models) 0-5000 PPMNO2 0-500 PPMDraft 0-40.00 in. H2O

Temperature 0-1500°CDetection Method: Electro Chemical Sensors

Power Requirement: 120 V AC, 30 watts; or Lead-Acid Rechargeable BatteriesApprox. Shipping Weight: 30 lbs

The ECOM-AC (Plus) is a portable unit for the quick measurement of O2, CO, temperature, NO and NO2. The micro-processor will calculate CO2 and combustion effi ciency. NO and NO2 sensors make simple determinations of these parameters. This instrument has a high fl ow pump assembly with an in-line water trap and particulate fi lter for proper conditioning of short-term samples.

The ECOM-AC (Plus) is capable of downloading into a computer for remote monitoring. The probe is 12” in length and has a 1/4” outer diameter with 10 ft. fl exible high temperature hose. It also has an automatic fresh air purge. The built-in printer in this unit can automatically print at predetermined time intervals.

Part Number 0703AC

Page 77: Clean Air Catalog

PORTABLE ANALYZERSPortable AnalyzersPortable AnalyzersPortable Analyzers

Portable AnalyzersPortable AnalyzersPortable Analyzers

Portable AnalyzersPortable AnalyzersPortable Analyzers

Testo 350 XL Portable Flue Gas Analyzer

3-43-43-4Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

The new version of the Testo Model 350 is the most innovative portable combustion analyzer to date. Features include interchangeable, pre-cal-ibrated sensors with temperature control; a CO sample dilution system for test range expansion; complete onboard sample conditioning; and an abundance of opportunities to interface with the entire system. The cells can be easily replaced or exchanged for greater testing fl exibility

Parameter RangeO2 0-25%CO 0-10000 ppm H2 compensated

CO Low 0-500 ppm (@0.1PPM) H2 compensatedNO 0-3000 ppm

NO Low 0-300 ppm (@0.1 PPM)NO2 0-500 ppmSO2 0-5000 ppmCxHy 0-4% (@ 0.01% resolution)H2S 0-300 ppm (@0.1PPM)

Dilution System CO only (adjustable to 40:1)CO Rinse Automatic over-range protection

Purge Valve Manual & auto fresh air & long term testingDifferential Pressure +/- 80” H2O (add pitot tube for velocity and fl ow)Detection Method: Electrochemical Sensors

Power Requirement: 110 –230, 90-260V, or rechargeable batteryApprox. Shipping Weight: 30 lbs.

Dimensions: actual 16” x 11” x 4”

Part Number Item350XLO2 02 replacement sensor - 300/350

350XLCOL CO low replacement sensor (0-500 ppm, H2 compensated, 0.1 ppm res.)350XLCO CO replacement sensor (0-10,000 ppm, H2 compensated)

350XLNO2 NO2 replacement sensor (0-500 ppm)350XLSO2 SO2 replacement sensor (0-5,000 ppm)350XLNOL NO low replacement sensor (0-300 ppm, 0.1 ppm res.)350XLNO NO replacement sensor (0-3,000 ppm)350XLHC HC replacement sensor 0-4% - 300350XLH2S H2S replacement sensor - 300 (0-300 ppm)

Part Number 0035XL

Page 78: Clean Air Catalog

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

Porta

ble A

nalyz

ers

PORTABLE ANALYZERS Testo 330 Portable Flue Gas Analyzer Testo 330 Portable Flue Gas Analyzer

3-53-53-5

Testo 335 Portable Flue Gas Analyzer Testo 335 Portable Flue Gas Analyzer

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Specifi cations• Constituents Measured: Temperature, Draft Pressure, O2, CO, NO, NO-LOW• Power Requirement: 110-230V, 90-260V or rechargeable battery• Approximate Weight: 1.5 lbs.

Specifi cations• Constituents Measured: Temperature, Draft Pressure, O2, CO, NO, NO-LOW• Power Requirement: 110-230V, 90-260V or rechargeable battery• Approximate Weight: 1.30 lbs.

Part Number Item33021 Testo 330-2 LL Kit #1 with O2, CO 33022 Testo 330-2 LL Kit #2 with O2, CO, NO & Printer

Part Number Item33051 Testo 335 Kit # 1 with O2 plus choice of 1 Sensor33052 Testo 335 Kit # 2 Standard Kit 02, CO 33053 Testo 335 Kit # 3 Engine Kit O2, CO, NO33054 Testo 335 Kit # 4 NO (x) Kit O2, CO, NO

Page 79: Clean Air Catalog

PORTABLE ANALYZERSPortable AnalyzersPortable AnalyzersPortable Analyzers

Portable AnalyzersPortable AnalyzersPortable Analyzers

Portable AnalyzersPortable AnalyzersPortable Analyzers

Testo 880 Portable Infrared Thermal Imager

3-63-63-6Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item088071 Testo 880 Basic Thermal Imager 088074 Testo 880 Expert Thermal Imager

The Testo 880 infrared Thermal Imager camera takes a digital picture of heat loss through walls, doors, windows, port holes and other sealing devices. The Thermal Imager can be used to identify faulty electrical connections by locating hot spots. The Testo 880 allows the user to see beyond the range of visible light and to capture images of object tem-peratures. The camera uses thermography technology that allows the user to acquire thermal imaging of multiple devices

Specifi cations• Store Capacity : 1 GB SD Card (Holds 1000 images)• Battery Type: Fast Charging, LI-ion Battery, Field Replaceable• System Requirement: Windows XP, Windows Vista• Approximate Weight: 2.0 lbs.

Part Number Item0563 0880 71 880-1 Thermal Imager (9Hz) with integrated digital camera0563 0880 73 880-3 Thermal Imager (33Hz) with integrated digital camera

0563 0880 74880-3 Expert Set Thermal Imager (33Hz) with integrated digital camera, including telephoto lens, battery charger, additional battery and display sunshield

Please contact service deptartment Retrofi t telephoto lens (for testo 880-3 only)0554 8801 External Two-bay Charger0554 8802 Additional battery0554 8804 Aluminum tripod0554 8805 Protective lens0554 8806 Display Sunshield0554 0051 Adhesive emissivity tape

Page 80: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s

4-14-14-1Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

Clean Air Engineering Express carries an ex-tensive line of sampling accessories to help complete your projects. Our large inventory al-lows us to ship any of these items overnight to your testing location. No more worries about down-time thanks to our 24-hour, 7 days-a-week emergency service.

Contact one of our account team members for more information on our source sampling ac-cessories or emergency service

01492

0769250

Page 81: Clean Air Catalog

Parts and AccessoriesParts and AccessoriesParts and Accessories

4-24-24-2

PARTS AND ACCESSORIES

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

PageFilter Holders & Frits ........................................... 4-3 47 mm Stainless Steel Filter Holder ................... 4-3 47 mm Tefl on Filter Holder .................................. 4-3 Cartridge Style Stainless Steel Filter Holder ....... 4-3 Fritted Holder ...................................................... 4-3 Disposable In line Filter ........................................ 4-3Peristaltic Pumps and Sample Pumps ............... 4-4 ADI Pumps .......................................................... 4-4 Gast Pumps ........................................................ 4-4 KNF Pumps ......................................................... 4-4 Masterfl ex Pumps ............................................... 4-4 Thomas Pumps ................................................... 4-4 Clean Air Pumps ................................................. 4-4Regulators ............................................................ 4-5 Brass Regulators ................................................ 4-5 Stainless Steel Regulators .................................. 4-5Heating Element ................................................... 4-6 Silicone Heaters .................................................. 4-6 High Temperature Glass Heaters ........................ 4-7 High Temperature Cable Heaters ........................ 4-7 Cartridge, Strip & Tubular Heaters ...................... 4-7Temperature Controllers ..................................... 4-8 Fuji Controllers .................................................... 4-8 Watlow Controllers .............................................. 4-8 Clean Air Controllers ........................................... 4-8Tubing and Pipe ................................................... 4-9 Stainless Steel Tubing and Pipe ......................... 4-9 Inconel Tubing and Pipe ..................................... 4-9 Titanium Tubing and Pipe ................................... 4-9 Flexible Tubing .................................................. 4-10 Tefl on® Tubing .................................................... 4-10Accessories ........................................................ 4-11 Tube Compression Fittings ............................... 4-11 Amphenol Connector Parts ..................................4-8 Flowmeters, Solenoids & Solid State Relays .... 4-12 Manometers and Replacement Parts ............... 4-12 Quick Wire Connectors & Equipment Fans ...... 4-14

PARTS & ACCESSORIES

®

0914

Page 82: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES 47 mm Stainless Steel In-Line Filter Holder 47 mm Stainless Steel In-Line Filter Holder

4-34-34-3

Disposable Inline Filter

Stainless Steel Fritted Filter Stainless Steel Fritted Filter

Cartridge Style Stainless Steel Filter Holder Cartridge Style Stainless Steel Filter Holder

47 mm Tefl on 47 mm Tefl on® In-Line Filter Holder® In-Line Filter Holder®

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 0561

Part Number Item9974 Cartridge Style Stainless Steel Filter Holder9975 Replacement micro-fi ber fi lter cartridge

47 mm Replacement Filter MediaPart Number Item

0620 47 mm Glass0620Q 47 mm Quartz0620T 47 mm Tefl on®

Lightweight umbilical construct-ed of two polyethylene pitot lines and one polyvinyl-coated thermocouple extension wire, wrapped in nylon mesh material.

Part Number 0558

Part Number 0740F

Part Number 0715PF

The 47 mm Tefl on® in-line fi lter holder has 1/4” compression connections and includes a TFE support screen.

The cartridge style stainless steel fi lter holder has 1/4” NPT connections and uses a micro-fi ber fi lter cartridge.

The Sintered Stainless Steel Fritted Filter is an excellent choice for keeping particulate out of your probes and lines. These 20 micron frits are cleanable and feature durable long lasting stainless steel construction with 1/4” NPT connection or connection of your choice.

The disposable inline fi lter has a semi-transparent Kynar housing with 1/4” O.D. tube ends and a micro-fi ber fi lter.

Page 83: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Peristaltic Pumps and Sample Pumps

4-44-44-4Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number Item9769T1 ADI Dia-Vac Pump, SS TFE Coated Head, TFE Diaphragm, 26 LPM, 24”Hg ,120 Vac.

9937 Gast Lubricated Rotary-vane Pump 120 / 240 Vac. 26.5” Max Vac. 4.5cfm open fl ow

9771BA Double Head Peristaltic Pump, 3 Roller Design, 120 Vac. 26ml per min, steel gears, continuous heavy duty motor

99390 Heated Head Pump, SS TFE Coated Head, TFE Diaphragm, 9 LPM, 120 Vac. 9711L KNF Diaphragm Pump (operates in any position) 115V/60Hz single head .03A9021 Masterfl ex Double Head Peristaltic Pump, 3 Roller Design, 120 Vac

0711R KNF Sample Pump, TFE Diaphragm, 5.5 LPM, 25”Hg, 120V w/ thermal reset99372 KNF Sample Pump, 120 Vac. 115V/60Hz9900 Submersible re-circulation Pump 120 Vac. 1/50 HP97691 Thomas Pump, TFE Coated Head, TFE Diaphragm, 120 Vac.9769 ADI Mini Dia-Vac Pump, TFE Coated Head, TFE Coated Diaphragm, 22 LPM, 22 “Hg, 120 Vac.

9769T1

97691

9900993720711R

90219711L99390

9771BA9937

9769

Page 84: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES Cylinder Regulators

4-54-54-5Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Brass Single Stage Regulators with Needle Valve and ¼” NPT OutletPart Number CGA Inlet Gauge Delivery Pressure

9764B350 350 0 – 4000 PSI 0 – 50 PSI9764B580 580 0 – 4000 PSI 0 – 50 PSI9764B590 590 0 – 4000 PSI 0 – 50 PSI

Stainless Steel 316 Regulators with Needle Valve and ¼” NPT OutletPart Number CGA Inlet Gauge Delivery Pressure

9764S330 330 0 – 4000 PSI 0 – 50 PSI9764S660 660 0 – 4000 PSI 0 – 50 PSI9764S705 705 0 – 4000 PSI 0 – 50 PSI

• Single Stage Brass Barstock Body• Six Port Confi guration 316L Stainless Steel Diaphragm• Custom CGA fi ttings and pressure ranges available.

• Single Stage 316L Stainless Steel Barstock Body• Six Port Confi guration 316L Stainless Steel Diaphragm• Custom CGA fi ttings and pressure ranges available.

Page 85: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Silicone Heaters

4-64-64-6Clean Air Express

A Division of Clean Air EngineeringPhone: (800) 223-3977 Fax: (847) 991-8924

Web site: www.cleanair.com

®

Part Number (120 Volt) Part Number (240 Volt) Width (Inches) Length (Inches) Total Watts01492 01482 1 35 175w01495 01485 1 72 360w01496 01486 1 80 400w01499 01489 1 120 600w014914 014814 1 140 700w014915 014815 1 180 900w014918 014818 1 216 1080w014920 014820 1 240 1200w014925 014825 1 300 1500w014930 014830 1 360 1800w014940 014840 1 480 2400w014950 014850 1 600 3000w

Silicone Rubber: Two layers of silicone rubber infused with fi berglass are vulcanized together and enclose the multiple strand wire resulting in a rugged yet fl exible sheath with excellent moisture, chemical and wear resistance. Maximum temperature rating for the heat tape is 500 °F. The thickness of the fl exible silicone rubber heater is 0.06”. The industrial heaters have silicone insulated wire leads of 2’ @ 18AWG. The silicone rubber heater is used in the majority of probes manufactured by Clean Air Express. The fl exible heaters length ranges from 35” thru 600”. The silicone rubber heaters power supply ranges from 120 volt to 240 volt.

Page 86: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES High Temperature Glass Heaters 1400°F max temperature

4-74-74-7

Tubular Heaters

Strip Heaters

Cartridge Heaters

High Temperature Cable Style Heaters

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item0491 2ft. 110v Insulated Heater 156w .5in width0494 4ft. 110v Insulated Heater 312w .5in width0495 6ft. 110v Insulated Heater 468w .5in width0496 8ft. 110v Insulated Heater 624w .5in width0699 10ft. 110v Insulated Heater 520w .5in width04914 12ft. 110v Insulated Heater 234w .5in width04916 16ft. 110v Insulated Heater 312w .5in width

0516PH 6ft. 110v Heater (no insulation) 312w .5in width0518PH 8ft. 110v Heater (no insulation) 416w .5in width

Part Number Item9120 Strip Heater 110v 300w91201 Strip Heater 240v 300w9739 Finned Strip Heater 110v 500w

Part Number Item97851 400w 110v ¼”NPT fi tting

Part Number Item9142 Tubular Heater 110v 500w91421 Tubular Heater 240v 500w

Part Number Item97862 112 inch 110v Cable Heater 302w .094”dia.97863 188 inch 110v Cable Heater 503w .094”dia.97223 223 inch 110v Cable Heater 3000w .125”dia.

* Heavy Insulated Heating Tape can tolerate tem-peratures up to 1400 °F.

Page 87: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Temperature Controllers

4-84-84-8

Amphenol Connector Parts

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item

91301 Fuji Electric PXR3 series Fuzzy Logic Controller 1/32 DIN with PID Auto-tune, Nema 4x faceplate, 100-240v AC input power (50/60Hz), 8 segment ramp/soak programming, relay or SSR outputs.

91304Fuji Electric PXR3 series Fuzzy Logic Controller 1/32 DIN with PID Auto-tune, Nema 4x faceplate24v AC/DC input power (50/60Hz), 8 segment ramp/soak programming, relay or SSR outputs and retrans-mission (4-20mA DC).

9130M Watlow Temperature Controller microprocessor based 1/16 DIN, single input, dual output 4 digit display, NEMA 4x rating, electromechanical relay, from C, 5A, CE complaint, without contact suppression.

9130Watlow Temperature Controller microprocessor base 1/16 DIN, single input, dual output 4 digit display, NEMA 4x rating, switched dc output, non insulated, from C, 5A, CE compliant, for use with solid state relay.

9131R Clean Air Express 6 Channel replacement indicator. Rugged and dependable.

3 Pin Amphenol Connector PartsPart Number Item

9402E 3 Pin Flanged Box Receptacle with Female Insert9403 3 Pin Cable Plug (Shell Only) 94031 3 Pin Male Insert94032 3 Pin Cable Clamp94033 3 Pin Female Insert

4 Pin Amphenol Connector PartsPart Number Item

9409 4 Pin Cable Clamp9410 4 Pin Cable Receptacle (shell only)9411 4 Pin Cable Plug (shell only)9412 4 Pin Flanged Box Receptacle with Male Insert 9416 4 Pin Female Insert9417 4 Pin Male Insert9418 4 Pin Flanged Box Plug with Female Insert

9402E

94032

9409

9412

9418

9403

94033

9411

9416

94031

9410

9417

Page 88: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES Stainless Steel Tubing and Pipe

4-94-94-9

Titanium Tubing and Pipe Titanium Tubing and Pipe

Inconel Tubing and Pipe

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item9304 1/4" x .035 Welded 304 SS9305 3/8” x .035 Welded 304 SS

9305065 3/8” x .065 Welded 304 SS9314A 3/8” Sch40 304 SS9308 1/2" x .035 Welded 304 SS

9308085 1/2" x .085 Welded 304 SS9316 1” x .035 Welded 304 SS9319 1” x .065 Welded 304 SS

9319083 1” x .083 Welded 304 SS9318 1 1/4" SCH 5 304 SS

93232 2 1/4" x .120 304 SS93233 4” x .083 304 SS9302 1/4” x 035 316 SS9306 3/8” x .035 316 SS9312 5/8” X .035 316 SS Seamless9317 1” X .035 316 SS9322 2” x .065 316 SS

Part Number Item9304I 1/4" .035 Inc 6009306I 3/8” .035 Inc 6009307I 3/8” .049 Inc 6009317I 1” .035 Inc 60092534I 1 1/4" .065 Inc 60092538 1 1/2" sch80 Inc 600

Part Number Item9302T 1/4" .035 Seamless9308T 1/2" .039302T5 Seamless9312T 5/8” .035 Seamless9317T 1” .035 Seamless9319T 1 1/4" .035 Seamless

Page 89: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Tefl on® Tubing® Tubing®

4-104-104-10

Flexible Tubing

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item9326 Gum Rubber Tubing 1/4 inch ID. X 3/16 inch wall93261 Gum Rubber Tubing 3/8 inch ID. X 3/16 inch wall9325 Flexible PVC 3/16 inch ID. X 5/16 inch OD.93252 Flexible PVC 1/8 inch ID. X 1/4 inch OD.9716 Neoprene Tubing 1/8 inch ID. X 3/8 inch OD.9012 Peristaltic Pump Tubing

932511 Polyethylene Tubing 1/4 inch ID. X 3/8 inch OD. 1126 Silicone Tubing 1/4 inch ID. X 3/8 inch OD.

Clean Air Express Tefl on® Tubing: Description: Tefl on® tubing is fl exible tubing that is resistant to crimping and blockage. This is the preferred tefl on® tubing for emissions measurement below 500F. For tube diameters or colors not listed here, please call. Material: Heavy Wall Polyester (PTFE) Tefl on® Tube.

Tefl on® is a registered trademark of DuPont. Tefl on® is the brand name for the Dupont fl uoropolymer plastic resins PTFE, FEP, and PFA. These three are very similar in composition, temperature limit and chemical resistance but have slightly different mechani-cal properties that make each one better suited for some specifi c applications. PTFE is best for most most gas sampling.

Tube OD Tube ID Tube Wall Part Number Color Bend Radius **1/8” 1/16” -0.031 0769125 Natural <0.3”1/4” 1/8” -0.062 0769250 Natural <0.5”1/4” 1/8” -0.062 0769250C Specify * <0.5”3/8” 1/4” -0.062 0769375 Natural <1.0”1/2” 3/8” -0.062 0769500 Natural <2.0”5/8” 1/2” -0.062 0769625 Natural <4.0”

• * Tefl on Tubing Colors Stocked are Green, Blue, Red & Yellow. If you need another color or size please call.

• ** Tefl on Tubing Bend radius is for room tem-perature bends. Heating tube to soft point prior to bending is best for permanent bends.

Page 90: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES Tube Compression Fittings Tube Compression Fittings

4-114-114-11

U RU UE UT UC BU

Union Reducing Union Union Elbow Union Tee Union Cross Bulkhead Union Needle Valve Tube Ends

TC MC ME MBT MRT PLG CAP

Thermocouple Connector

Male Connector

Male Elbow Male Branch Tee

Male Run Tee

Plug Cap

FC FE FRT PC RPC TEMA TEBA

Female Connector

Female Elbow Female Run Tee

Port Connector Reducing Port Connector

Tube End Male Adapter

Tube End Bulkhead Adapt

FQCB MQCB FQC MQC N F

Female Quick Connect Bulkhead

Male Quick Connect Bulkhead

Female Quick Connect

Male Quick Connect

Coarse Valve Tube Ends

Nut Ferrule

1 2 3 Example: 0418 – S - UT (¼” Stainless Steel Tee)

1 Size

2 Material

3 Configuration

0417 = 1/8” S = Stainless Steel U = Union 0418 = ¼” B = Brass RU = Reducing Union 0419 = 3/8” G = Graphite UE = Union Elbow 0420 = 1/2” T = Teflon UT = Union Tee 0421 = 5/8” K = Kynar (PVDF) UC = Union Cross 0422 = ¾” BU = Bulkhead Union 0423 = 1” TC = Thermocouple Connector MC = Male Connector ME = Male Elbow MBT = Male Branch Tee MRT = Male Run Tee PLG = Plug CAP = Cap FC = Female Connector FE = Female Elbow FRT = Female Run Tee PC = Port Connector RPC = Reducing Port Connector TEMA = Tube End Male Adapter TEBA = Tube End Bulkhead Adapter FQCB = Female Quick Connect Bulkhead MQCB = Male Quick Connect Bulkhead FQC = Female Quick Connect MQC = Male Quick Connect N = Nut F = Ferrule

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Page 91: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Flowmeters

4-124-124-12

Manometer and Replacement Parts

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Rate-Master Flowmeters with SS Valve Through-panel mountingPart Number Range

0756 100 – 1000 cc/min0757 .1 – 1 LPM97482 1 – 10 LPM97483 2 – 25 LPM

65mm Glass Single and Dual Float Flow meter Non ValvePart Number Range

9969 Steel = 0 – 2.52 LPM Glass = 0 – 1.25 LPM00151 Glass = 0 - 1.25 LPM

Visi-Float Flowmeters with SS Valve Flush - panel mountingPart Number Range

9746 .15 – 1 LPM9747 .6 – 5 LPM9748 1 – 10 LPM

Visi-Float Flowmeters Non Valved Flush - panel mountingPart Number Range

97471 .6 – 5 LPM97481 1 – 10 LPM

Part Number Item00588 Dual Column Panel Mount Manometer 0-8” H2O

00588M Dual Column Panel Mount Manometer 0-200mm H2O0058A Manometer Adjustment Knob

00588C Manometer Type C Plug0058R Manometer Oil Red0058Y Manometer Oil Yellow9100F Manometer Female Quick Connect 9100M Manometer Male Quick Connect 005588

0058Y

0058C0058A

9100M9100F

0058

R

Page 92: Clean Air Catalog

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

sPa

rts an

d Acc

esso

ries

Parts

and A

cces

sorie

s PARTS AND ACCESSORIES Solenoid and Pinch Valves

4-134-134-13

Solid State Relays

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number 9129

Crydom Solid State Relays offer state-of-the art Surface Mount Technology. These relays deliver proven reliability in the most demanding applications. 25A 240VAC DC

We stock many types of pinch and solenoid valves. Please call a Sales Represen-tative for price and delivery.

Part Number Item Voltage9762 ASCO Pinch Valves 110 – 220 –24VDC9761 Stainless Steel 2-way 12VDC9759 Stainless Steel 3-way 12VDC9127 Stainless Steel norm/close 3-way 125psi 120V91275 Stainless Steel 3-way multi purpose 120V

91271-1 Stainless Steel norm/closes 2-way 45psi 12VDC91271 Stainless Steel norm/close 3-way 125psi 240V

Part Number 0914

Crouzet Solid State Relays offer state-of-art Din Rail Mount Technology. These relays deliver proven reliability in the most demanding applications. Features include: Input LED, Din Rail Mountable, and Current Regulated Input

Page 93: Clean Air Catalog

PARTS AND ACCESSORIESParts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Parts and AccessoriesParts and AccessoriesParts and Accessories

Quick-Wire Connectors

4-144-144-14

Equipment Cooling Fan

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

®

Part Number Item91351 Straight Blade Plug 5-15 125VAC 15AMP9135A Straight Blade Plug 6-15 250VAC 15AMP91361 Plug Receptacle 5-15 125VAC 15AMP

Part Number Item9142 Tubular Heater 110v 500w91421 Tubular Heater 240v 500w

Compact and ready to install, these fans are a popular choice for cooling heat-sensitive equipment.

Hinged impact resistant nylon housing provides easy access for wiring. Both are 2 pole 3 wire (3 blades –2 power plus 1 ground) Color is high-visibility yellow; 5-15 and 5-20 NEMA models Meet Fed. Spec. WC596 and are UL listed

Page 94: Clean Air Catalog

ORDERING NOTES

Clean Air ExpressA Division of Clean Air Engineering

Phone: (800) 223-3977 Fax: (847) 991-8924Web site: www.cleanair.com

Date Item Ordered Size Qty Shipping Date Project #/ Name

®