Cisco IX5000 and IX5200 Installation Guide Page 1-1 © 2015 Cisco Systems, Inc. All rights reserved. Cisco TelePresence IX5000 and IX5200 Installation Guide Revised: November 6, 2017 - Summary of Changes: November 6, 2017: Removed the wiring diagram and put in the URL to the separate document. July 20, 2017: Updated cable routing and wiring diagrams. April 14, 2017: Added section Important Updates for the Room Readiness Assessment and Network Path AssessmentJuly 8, 2015: Added picture of the microphone bar cap in its packaging to page 1-5 July 7, 2015: Added information about the inside table legs being specific to the left and right sides (page 1-5) June 23, 2015: Added information to page 7-4 to show where to find the 800- number for the front inside table legs June 23, 2015: Changed page 15-6 to show correct positioning of lower corner cabinets June 5, 2015: Fixed step numbering in Chapter 13 May 13 2015: Added extra wording to denote the display connections (Chapter 9) May 11, 2015: o Added procedure to install the optional seismic bracket (pages B-1 through B-10) and added extra steps and required tools for this procedure (Chapter 1) o Added procedure to check that the two inside table legs have the plate installed correctly (Step 1 on page 7-2) o Added first-time setup requirements to the ‘‘Important Notes’’ section on page 1-6 o Added note on page 1-5 to not throw away any boxes before installation is complete, as small parts can be hidden in the packaging

Upload: lamdien

Post on 24-Jan-2017

255 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-1 © 2015 Cisco Systems, Inc. All rights reserved.

Cisco TelePresence IX5000 and IX5200 Installation Guide Revised: November 6, 2017 - Summary of Changes: November 6, 2017: Removed the wiring diagram and put in the URL to the separate document. July 20, 2017: Updated cable routing and wiring diagrams. April 14, 2017: Added section “Important Updates for the Room Readiness Assessment and Network Path Assessment” July 8, 2015: Added picture of the microphone bar cap in its packaging to page 1-5 July 7, 2015: Added information about the inside table legs being specific to the left and right sides (page 1-5) June 23, 2015: Added information to page 7-4 to show where to find the 800- number for the front inside table legs June 23, 2015: Changed page 15-6 to show correct positioning of lower corner cabinets June 5, 2015: Fixed step numbering in Chapter 13 May 13 2015: Added extra wording to denote the display connections (Chapter 9) May 11, 2015: o Added procedure to install the optional seismic bracket (pages B-1 through B-10) and added extra steps and required tools for this procedure (Chapter 1) o Added procedure to check that the two inside table legs have the plate installed correctly (Step 1 on page 7-2) o Added first-time setup requirements to the ‘‘Important Notes’’ section on page 1-6 o Added note on page 1-5 to not throw away any boxes before installation is complete, as small parts can be hidden in the packaging

Page 2: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-2 © 2015 Cisco Systems, Inc. All rights reserved.

Page 3: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-3 © 2015 Cisco Systems, Inc. All rights reserved.

Important Updates for the Room Readiness Assessment and Network Path Assessment

While immersive telepresence orders are processed in the same way as other Cisco collaboration endpoints, the Cisco Advanced Technology Partner (ATP) performs additional network and room readiness before the system is installed in the customer premises. It is the partner’s responsibility to make sure that all network and room readiness is performed prior to the system being powered on and connected to the customer’s network. This preparation ensures the best immersive experience.

The room readiness information was previously performed by partners using the Room Readiness Assessment (RRA) tool. The partner will make sure that the room in which the system is installed follows all room requirements. For the latest room size, power, HVAC, lighting, and acoustic requirements for your immersive TelePresence room, refer to the following document:

• “Cisco TelePresence IX5000 and IX5200 Room Requirements” document at https://www.cisco.com/c/en/us/td/docs/telepresence/ix5000/recommendations/ix5000_room_requirements.html

The partner will design and implement your network for your immersive system using the latest requirements and guidelines for bandwidth, Quality of Service (QoS), latency, packet loss, and packet jitter. For network design considerations and IX5000 bandwidth requirements, see the following documents:

• ‘‘Cisco Collaboration System 11.x Solution Reference Network Designs (SRND)’’ document at: https://www.cisco.com/c/en/us/td/docs/voice_ip_comm/cucm/srnd/collab11/collab11.html

• ‘‘IX System Network and Bandwidth Requirements’’ section of the ‘‘Administration Guide for Cisco TelePresence Software Release IX8’’ at: https://www.cisco.com/c/en/us/td/docs/telepresence/ix_sw/8_x/admin/guide/ix_8_admin_guide.html

Page 4: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-4 © 2015 Cisco Systems, Inc. All rights reserved.

Installation Sequence

Move packaging and unpack

Assemble and level lower and upper display frames

Install cable runner base and table structure assembly

Install pillars, crossbars, rear kick plate and toe cap, codec, woofer, speakers, optional switch

Initial endpoint cabling

Install displays, final endpoint cabling, structure leveling

Install front kick plates Install camera and light panels

Install tabletops

Install software on endpoint and register to UCM, assist Installer 2 with install tasks, reboot system

First-time setup (camera tuning, white board setup, speaker and light testing), assist with final

installation and cleanup tasks

Install table electronic components (mic bars, mute buttons, cable retractor, metal cable covers)

Final installation (thermoformed panels, fascia, camera cover, and cable cap), begin cleanup

Run test calls, complete final installation, complete room cleanup

Installer 2 Installer 1

Initial cabling of table assembly

Page 5: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-5 © 2015 Cisco Systems, Inc. All rights reserved.

Installation Quick Reference 1. Move material and unpack (2 people required) 2. Install the lower display frames (2 people required) 3. (Systems that include seismic brackets only) measure, drill for, and install the seismic brackets (see the ‘‘Installing the Seismic

Bracket’’ chapter on page C-1) (2 people required). Note that this step adds extra time to the installation. 4. Install the upper display frames (2 people required) 5. Install the cable runner 6. Install the upper crossbars, rear kick plates, and toe caps 7. Install the codecs, PDUs, subwoofer, speakers, and optional endpoint switches into the endpoint structure

Note: The switches in the endpoint structure are optional items. The switches in the table legs to connect the Touch 10 device(s) are required for the Touch 10 device(s).

8. Install the table legs and electronic equipment (Ethernet/power modules for table legs, microphone connector (MC), PoE switch) for the front row table, and begin cabling procedures for the table (2 people required for some steps)

9. Perform cable routing for all installed equipment (codecs, PDUs, subwoofer, and speakers for the endpoint structure, and power/ laptop connectivity and PDUs for the table legs) AND place the cables for the light panels and camera

10. Install the displays, light panels, and camera, including cabling 11. Install the front kick plates and toe caps 12. Install the front row tabletops (2 people required) 13. Install and cable the microphone bars, mute buttons, retractors/presentation cables 14. (IX5200 systems only) install and cable the second row table (2 people required for some steps) 15. Install the PET, fascias, display trim and thermoformed outer panels (2 people required) 16. Install software, register endpoint to Unified CM, perform first-time setup, run test calls 17. Room cleanup

Page 6: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-6 © 2015 Cisco Systems, Inc. All rights reserved.

Required Tools o Metric Allen (hex) set o 6mm T-handle hex key o 7mm hex socket driver o #0, #1, #2 and #3 Phillips drivers o Snips and long nose pliers o Extensions for Phillips bits/long handle screw

drivers o Cordless driver o Socket wrench set (metric) o 10mm, 13mm & 19mm wrench and adjustable

wrench o 19mm 12-point ratcheting box end wrench o Spirit level or digital Level o Laser level with tripod o White gloves (included with accessory kit) o Metric tape measure o Box cutter

Tools for Optional Seismic Bracket

o #3 Phillips Driver o Drill and 1/2-inch (12.7mm) carbide drill bit o 1 1/8 inch or 29mm open-end or box-end

wrenches or adjustable wrenches o Torque wrench with 75 foot-pound (102 N-m) or

greater capacity o 9/16 inch or 15mm socket o Measuring tape o Compressed air source (canned compressed air

is acceptable) to clean the holes after drilling

Page 7: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Page 1-7 © 2015 Cisco Systems, Inc. All rights reserved.

Important Notes for installing the IX5000 and IX5200 o In this manual, Left or Right always means ‘‘left or right as viewed facing the front of the system’’. Installation of the IX system

is very different than the TX9000, CTS-3000, or CTS-3010 systems, even though the components are similar. o Display installation is completely different. The displays rest on shelves and levelers in the endpoint structure. The display spools

are only used to adjust the front-back position of the outer edge of the left and right display. Measure spool distance carefully before installing the displays or the spool cannot drop into its place in the display frame. You can adjust the spools inward or outward after installation.

o Each cable has a reference designator (printed label) attached to each end. When installing cables, check the cabling diagram and make sure that each reference designator on the cable corresponds to the correct reference designator on the electrical component in the table or endpoint structure.

o Some small parts are partially hidden in some bulky packaging. Do not throw any packaging away until you finish installing the system.

o In many cases, you cannot use a power driver when installing fasteners (screws). Use a manual screwdriver instead. Do not use a power driver when installing the following components: o The speakers and speaker blocks o Any component that uses captive screws (the cable runner and speaker

cover) o Many of the thermoformed and PET outer panels

Follow the instructions in the manual when installing these parts. o The two inner legs for the front row are different, even though they look similar. Do not switch right for left and vice versa. If

incorrectly installed, the magnets in the legs will not attach the side panels correctly.

Page 8: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cisco IX5000 and IX5200 Installation Guide

Important Notes cont’d After you install the system, follow the instructions exactly to install the latest IX software and configure your system for the first time in the ‘‘IX5000 and IX5200 First-Time Setup’’ document at https://www.cisco.com/c/en/us/td/docs/telepresence/ix5000/first_time_setup/ix5000_first_time_setup.html. Failure to do so can make the switch in the table or the Touch 10 devices inoperable.

Finding Immersive Room Requirements

For the latest room size, power, HVAC, lighting, and acoustic recommendations for your immersive TelePresence room, refer to the ‘‘Cisco TelePresence IX5000 and IX5200 Room Requirements’’ document at https://www.cisco.com/c/en/us/td/docs/telepresence/ix5000/recommendations/ix5000_room_requirements.html

Page 9: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 1-9 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Lower and Upper Display Frames

Page 10: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-2 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Lower and Upper Display Frames

Required Parts o 1x each left, center, and right lower display frames (800-

40923-xx, 800-40920-xx, 800-40928-xx) o 1x each left, center, and right upper display frames

(800-40934-xx, 800-40948-xx, 800-40941-xx) o 2x Tie bars 700-43084-xx o 56x black M8 X 16mm screws 69-2792-xx o 1x compliance label 47-27415-xx

Required Tools o #3 Phillips Driver o 13mm wrench or adjustable wrench o 19mm 12-point ratcheting box end wrench o Metric tape measure o Spirit level o Laser level

Page 11: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-1 © 2015 Cisco Systems, Inc. All rights reserved.

1

Place the left, center, and right lower display frames (800-40923-xx left, 800-40920-xx center, 800- 40928-xx right) upside-down on the floor, and check that there is 2 inches (51mm) from the bottom of

the frame to the bottom of the feet. If adjustment is required, loosen the 19mm lock nut.

2’’ (51 mm)

Leveling foot 19mm lock nut

Page 12: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 13: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Place the center frame where you want the center of the system to be. The center frame has a diamond in the center of the frame for this purpose. Assemble the lower left frame 800-40923-xx to the lower

center frame 800-40920-xx. Align the pins on the side of 800-40920-xx with the hole and slot on the side of 800-40923-xx. Install and tighten 6x black M8 X 16mm screws 69-2792-xx using a #3 Phillips driver.

800-40920-xx

800-40923-xx

Diamond shows center

of system

6x 69-2792-xx

Page 14: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Attach the lower right frame 800-40928-xx to the display structure. Align the pins on the side of 800- 40928-xx with the hole and slot on the side of 800-40920-xx. Install 6x black M8 X 16mm screws 69-2792-xx and tighten using a #3 Phillips driver.

6x 69-2792-xx

800-40928-xx 800-40920-xx

Page 15: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Set the frame position from the rear wall. The distance should be a minimum of 150mm (6 inches) from the back of the frame to the wall. Measure two positions (left side and right side of the center frame) to

ensure that the frame is parallel to the rear wall.

Minimum 6’’ (150 mm)

Rea r W all

Page 16: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 2-6 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Lower and Upper Display Frames

5

Level the system end-to-end using a laser level. Use the diamond-shaped leveling marks as a guide for the horizontal level. Note: When leveling the system, use the outside feet of the two outside display frames (Foot

A in the illustration) and both feet of the center display frame (Foot C in the illustration). Loosen the 19mm lock nut on the leveling feet, and adjust the feet using the 13mm hex profile above each foot. Systems using the seismic bracket only: Measure and center the frames, then place the seismic brackets under the frames and mark the drilling holes. See the “Installing the Seismic Bracket” on page C-1 for more information.

Foot C Foot B Foot C Foot B

Diamond-shaped leveling mark

Foot A

Foot A

19mm Lock nut

13mm hex profile

Page 17: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 2-7 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Lower and Upper Display Frames

Adjust the system for plumb (side-to-side) adjustment by raising or lowering the two outer feet marked “A” by the same amount while checking plumb with a level.

Foot A

Foot A

6

Page 18: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-8 © 2015 Cisco Systems, Inc. All rights reserved.

7

Assemble the upper center frame 800-40948-xx to the lower center frame 800-40920-xx. Align the pins on the lower frame with the slot and hole on the upper frame (a slot on the left side of the upper

frame, a hole on the right). Install 8x black M8 X 16mm screws 69-2792-xx and tighten with a #3 Phillips driver.

Pin

8x 69-2792-xx

Slot

800-40948-xx

Page 19: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-9 © 2015 Cisco Systems, Inc. All rights reserved.

8a

Assemble the upper left frame 800-40934-xx to the display structure. Align the slots and pins in the vertical beams, then place the upper frame on the lower frame and align the pin and slot in the

horizontal beams.

800-40934-xx

Slot

800-40923-xx Pin

Page 20: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-10 © 2015 Cisco Systems, Inc. All rights reserved.

8b

Install 8x black M8 X 16mm screws 69-2792-xx in the vertical columns and tighten using a #3 Phillips driver. Install and tighten these screws before installing the screws on the horizontal

beam.

8x 69-2792-xx

800-40934-xx

Page 21: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-11 © 2015 Cisco Systems, Inc. All rights reserved.

Install 6x black M8 X 16mm screws 69-2792-xx in the horizontal beam and tighten using a #3 Phillips driver.

6x 69-2792-xx

800-40923-xx

800-40934-xx

8c

Page 22: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

9

Install the upper right frame 800-40941-xx to the display structure following the same procedure as the upper left frame using 14x black M8 X 16mm 69-2792-xx screws. Install and tighten the side

screws first.

6x 69-2792-xx

Page 2-12 © 2015 Cisco Systems, Inc. All rights reserved.

800-40928-xx

800-40941-xx

8x 69-2792-xx

Page 23: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-13 © 2015 Cisco Systems, Inc. All rights reserved.

10

Set the height of the 2 levelers in the upper frame (one leveler shown) to 2 3/8 inches (60 mm) between the surface of the beam and the top of the leveler pad. Loosen the lock nut using a 13mm or adjustable wrench

before adjusting the height of the leveler. Do not re-tighten the lock nut.

2 3/8’’ (60 mm)

Page 24: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Assemble 2x tie bars 700-43084-xx to the rear left and right sides of the frames using 8x black M8 X 16mm screws 69-2792-xx.

Page 2-14 © 2015 Cisco Systems, Inc. All rights reserved.

8x 69-2792-xx

2x 700-43084-xx

11

Page 25: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-15 © 2015 Cisco Systems, Inc. All rights reserved.

Laser level is aligned with the left point of the diamond

12

Make sure that the outside corners of the structure are an equal distance from the wall, then level the display frames for level and plumb (horizontal and vertical), using 2x Foot A and 2x Foot C. Make

sure that all feet touch the floor after leveling. NOTE: Lean the structure a few degrees toward the wall (backwards). After you install the displays, the structure will lean slightly forward and bring it back to level.

Foot C Foot B Foot A

Make sure that distance from wall is even

Page 26: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Lower and Upper Display Frames

Page 2-16 © 2015 Cisco Systems, Inc. All rights reserved.

Attach the compliance label 47-27415-xx to the pillar on the left side of the lower left display frame. Use the four locating marks on the frame to find the correct placement.

1x 47-27415-xx

13

Page 27: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Cable Runner

Page 3-1 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Cable Runner

Required Parts Parts needed: o 1x Cable runner 700-42946-xx o 2x Cable runner bridges 700-43302-xx o 4x Black M4 X 12mm long screws with external lock washer 48-2426-xx o 1x Cable runner plate 700-44717-xx o 4x M6x10mm screws 69-2803-xx

Required Tools o #2 and #3 Phillips Driver o 6mm T-handle hex driver

Page 28: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Cable Runner

Page 3-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

a. Assemble the 2x cable runner bridges 700-43302-xx to the cable runner base 700-42946-xx with 4x black M4x12mm screws 48-2426-xx using a #2 Phillips screwdriver. b. Install the cable runner plate

to the cable runner 700-42946-xx with 4x M6x10mm screws 69-2803-xx.

700-43302-xx

4x 48-2426-xx

700-42946-xx

4x 69-2803-xx

700-44717-xx

Page 29: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Cable Runner

© 2015 Cisco Systems, Inc. All rights reserved.

2

a. Slide the cable runner base into position under the lower center frame. b. Loosen the 6x hex screws (3x per cable runner bracket) using a 6mm T-handle hex driver. Place the hex driver through the access

holes in the frame beam as required. c. Lower the runner brackets through the cutouts in the runner until both brackets are resting on the lower part of the runner (not on the ribs).

Page 3-3

b. Loosen 3x screws on each side

a. Slide the cable runner into position

c. Lower the brackets

Page 30: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Cable Runner

Page 3-4 © 2015 Cisco Systems, Inc. All rights reserved.

d. Attach the 4x captive fasteners (2x fasteners per bracket) on the cable runner to the display frames. e. Re-tighten the 6x M8 screws on both brackets with the hex driver.

e. d.

d. e.

3

Page 31: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

© 2015 Cisco Systems, Inc. All rights reserved.

Page 4-1

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap Required Parts Pillars: o 4x 700-43514-xx (inside, outside, 2x center) o 2x 700-43515-xx (far center-right and center-left) o 2x 700-43516-xx (near center-right and center-left) o 32x Black M4 X 12mm long screws with external lock washer 69-2797-xx Crossbars: o 3x crossbar pieces (700-43519-xx left, 700-43517-xx center, 700-43518-xx

right) o 16x Black M4 X 12mm long screw with external lock washer 69-2797-xx Rear kick plates: o 3x Center, left, and right rear kick plates (center 700-43100-xx, left 700-43101-

xx, right 700-43099-xx) o 6x M4 nut with lock washer 69-2793-xx

Required Tools o Crossbar: #2 Phillips screwdriver • Kick Plate and Toe Cap: 7mm Hex Driver • Kick Plate only: cardboard spacer

o 1x Cardboard spacer no part number, attached to the cable runner base Rear toe caps: o 3x Center, left, and right toe caps (center 700-43094-xx, left 700-43095-xx,

right 700-43093-xx) o 10x M4 nut with lock washer 69-2793-xx

Page 32: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-2 © 2015 Cisco Systems, Inc. All rights reserved.

4x 69-2797-xx

Tab Tab

Tab

700-43514-xx 700-43516-xx 700-43516-xx 700-43514-xx

700-43515-xx

1

Install the pillars (4x 700-43514-xx, 2x 700-43515-xx, 2x 700-43516-xx) into the frame by aligning the tabs in the pillars into the slots on the frame. Attach the pillars to the frame with 32x M4 X 12mm screws

(4x for each pillar) using a #2 Phillips screwdriver.

2x 700-43514-xx

Page 33: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

© 2015 Cisco Systems, Inc. All rights reserved.

Page 4-1

Place the horizontal crossbars (700-43519-xx left, 700-43517-xx center, 700-43518-xx right) on the pillars and fasten with 14x black M4 X 12mm screws 69-2797-xx using a #2 screwdriver.

700-43517-xx 700-43519-xx

700-43518-xx

Tab

Tab Tab

14x 69-2797-xx

2

Page 34: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-4 © 2015 Cisco Systems, Inc. All rights reserved.

Attach the lower rear kick plate 700-43100-xx to the endpoint structure. Align the threaded studs to the slots in the display stand, then loosely install (but do not fully tighten) using 2x M4 nuts 69-2793-xx.

700-43100-xx

2x 69-2793-xx

3

Page 35: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

© 2015 Cisco Systems, Inc. All rights reserved.

4

Place the cardboard spacer (attached to the cable runner base) between the cable runner 700-42946- xx and the rear kick plate 700-43100-xx. Level the rear kick plate with a spirit level. Verify that the kick

plate is at least 26mm (1 inch) above the highest point on the floor (measured on both the left or right side of the kick plate), then tighten the 2x M4 nuts you attached in Step 3. Save the spacer. You will use it when you install the front kick plates.

Minimum 1’’ (26 mm)

Minimum 1’’ (26 mm)

2x 69-2793-xx (viewed from opposite side)

Cardboard spacer

Page 4-5

Page 36: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-6 © 2015 Cisco Systems, Inc. All rights reserved.

Install the rear center toe cap 700-43094-xx to the kick plate by placing the threaded studs into the holes in the display stand and installing and tightening the 4x M4 nuts 69-2793-xx.

700-43094-xx

Stud

Hole

4x 69-2793-xx

5

Page 37: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-7 © 2015 Cisco Systems, Inc. All rights reserved.

6a

Attach the left and right rear kick plates (left 700-43101-xx, right 700-43099-xx). a. Hook the pin on the rear side kick plates over the notch in the rear center kick plate. b. Place the studs (one for each

kick plate) into the slot in the frame.

a. Pin

Notch

700-43099-xx Slot 700-43101-xx

b. Stud

Page 38: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-8 © 2015 Cisco Systems, Inc. All rights reserved.

c. Using a level, level the rear side kick plates with the rear center kick plate. d. Attach the x2 M4 nuts with lock washer 69-2793-xx to the stud for each plate and tighten with the 7mm hex driver.

c. Level here

d. 2x 69-2793-xx

6b

Page 39: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Pillars, Crossbars, and Rear Kick Plate/Toe Cap

Page 4-9 © 2015 Cisco Systems, Inc. All rights reserved.

7

Install the side toe caps (left 700-43095-xx, right 700-43093-xx). Place the studs in the left toe cap 700-43095-xx into the holes in frame. Attach the x3 M4 nuts with lock washer 69-2793-xx to the stud

and tighten with the 7mm hex driver. Repeat for the right toe cap.

700-43093-xx

700-43095-xx

Hole Stud

6x 69-2793-xx

Page 40: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 41: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Codecs, PDUs, and Optional LAN Switches

Page 5-1 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Codecs, PDUs, and Optional LAN Switches

Required Parts Codecs: o 1x encoder/decoder codec 800-39337-xx o 1x each encoder/decoder codec mounting brackets 700-43404-

xx left, 700-44771-xx right o 1x host CPU codec 800-41502-xx o 1x each host CPU codec mounting brackets 700-43404-xx left,

700-43573-xx right o 12x black M8x16mm screws with external tooth lock washer 69-

2792-xx o 16x black M4x12mm screws with external tooth lock washer 69-

2797-xx Optional LAN Switches: Note: The switches in the endpoint structure are optional items that can be used for the Ethernet connectivity modules from the table legs. You install switches in the table assembly for the Touch 10 device(s) in a later procedure; these are required. o 2x WS-C2960C-12PC-L switch o Upper and lower switch brackets (700-43091-xx top), 700-

43090-xx bottom) o 4x black 10-32x10mm screw with external tooth lock washer

69-100186-xx (part of kit 69-100184-xx and included with the switch brackets)

o 4x black M4x12 mm screw with external tooth lock washer 69-100185-xx (part of kit 69-100184-xx and included with the switch brackets)

Required Tools #2 and #3 Phillips driver

Page 42: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Codecs, PDUs, and Optional LAN Switches

© 2015 Cisco Systems, Inc. All rights reserved.

Assemble the brackets (700-43404-xx left, 700-44771-xx right) to the sides of the encoder/decoder codec 800-39337-xx using 8x black M4x12mm screws 69-2797-xx. Tighten with a #2 Phillips driver.

4x 69-2797-xx

4x 69-2797-xx

700-44771-xx 800-39337-xx

700-43404-xx

1

Page 43: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Codecs, PDUs, and Optional LAN Switches

Page 5-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Assemble the encoder/decoder codec to the lower center frame by engaging the bracket hooks with the slots in the frame and then lowering the box until the hooks rest on the bottom of the slots. Install

6x black M8x16mm screws 69-2792-xx and tighten with a #3 Phillips driver.

Slot

Hook 800-39337-xx

6x 69-2792-xx

Page 44: Cisco TelePresence IX5000 and IX5200 Installation Guide

© 2015 Cisco Systems, Inc. All rights reserved.

Installing the Codecs, PDUs, and Optional LAN Switches

Assemble the brackets (700-43404-xx left, 700-43573-xx right) to the sides of the Host CPU codec 800-41502-xx using 8x black M4x12mm screws 69-2797-xx. Tighten with a #2 Phillips driver.

700-43573-xx 700-43404-xx

800-41502-xx

4x 69-2797-xx 4x 69-2797-xx

3

Page 45: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 5-5 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Codecs, PDUs, and Optional LAN Switches

4

Assemble the Host CPU codec to the lower center frame by resting the box on the bottom beam and rotating / sliding into place. Engage the hook on the left side bracket with the slot in the frame. Install

using 6x black M8x16mm screws 69-2792-xx and tighten with a #3 Phillips driver.

800-41502-xx

Hook Slot

6x 69-2792-xx

Page 46: Cisco TelePresence IX5000 and IX5200 Installation Guide

© 2015 Cisco Systems, Inc. All rights reserved.

Installing the Codecs, PDUs, and Optional LAN Switches

5a

Optional: Installing the LAN switches: Orient the switches WS-C2960C-12PC-L as shown and assemble the brackets (700-43091-xx top, 700-43090-xx bottom) using x4 black 10-32 X 10mm

screws 69-100184-xx (included with the switch brackets). Engage the tabs on the brackets with the slots in the switches. Tighten the screws with a #2 Phillips driver.

700-43090-xx

2x WS-C2960C-12PC-L

Slot

700-43091-xx Tab

4x 69-100184-xx

Page 47: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 5-7 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Codecs, PDUs, and Optional LAN Switches

5b

Optional: Installing the LAN switches: Install the switches and brackets by engaging the two bottom hooks in the slots in the frames. Install 4x black M4 X 12mm screws 69-2797-xx and tighten

with a #2 Phillips driver.

Hook

Slot 4x 69-2797-xx

Page 48: Cisco TelePresence IX5000 and IX5200 Installation Guide

© 2015 Cisco Systems, Inc. All rights reserved.

Installing the Subwoofer and Speakers

Required Parts Woofer:

Installing the Subwoofer and Speakers Required Tools #2 Phillips driver

o 1x Power amp 800-42333-xx o 1x woofer 74-12848-xx o 1x woofer bracket 700-43076-xx o 1x power supply 341-0414-xx o 8x black M4 x12mm screws 69-2797-xx o 2x silver M4 washer 69-2796-xx o 2x M4 nut with lock washer 69-2793-xx Speakers: o 6x Speakers 74-12204-xx

7mm hex socket driver

Page 6-1 © 2015 Cisco Systems, Inc. All rights reserved.

o 2x Speaker Mounting Block 700-47073-xx o 48x Black M3 Shoulder Screw 69-2791-xx

Page 49: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 50: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

Install the power amp 800-42333-xx on the power bracket on the left display frame. Install 2x M4 nuts 69-2793-xx on the threaded studs and tighten with a 7mm hex socket driver. Insert the power supply

341-0414-xx into the channel on the back of the bracket and plug the power supply into the bottom of the amp.

800-42333-xx

2x 69-2793-xx

341-0414-xx Cord from power supply plugs into amp

Page 51: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Assemble the bracket 700-43076-xx to the woofer 74-12848-xx. Insert the standoffs in the bracket into the rubber grommets on the woofer. Install the 2x silver M4 washers 69-2796-xx to the 2x M4x12mm

screws 69-2797-xx and tighten with a #2 Phillips driver.

700-43076-xx

2x 69-2796-xx

2x 69-2797-xx

74-12848-xx - back side

Page 52: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Install the woofer by rotating it forward and placing it into the lower left display frame, making sure that the woofer feet are located within the sheet metal forms on the frame. Rotate the woofer backward,

install 2x M4x12mm screws 69-2797-xx, and tighten with a #2 Phillips driver.

2x 69-2797-xx

Rubber feet

Page 53: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-5 © 2015 Cisco Systems, Inc. All rights reserved.

4a

Install the speakers. Attach the 2x Speaker Mounting Blocks 700-47073-xx to the center pillars with 4x Black M3 Shoulder Screws 69-2791-xx (2x per pillar). NOTE: only the two center vertical pillars

use this block. Note the speaker icon, which points toward the speakers after they are installed.

2x 700-47073-xx

4x 69-2791-xx

Note speaker icon - points toward

speaker Center pillars

Page 54: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-6 © 2015 Cisco Systems, Inc. All rights reserved.

4b

Mount the speaker 74-12204-xx to the rubber block and attach it using 4x Black M3 shoulder screws 69-2791-xx per speaker. Do not use a power driver for these screws, as this might cause

damage to the thread inserts.

4x 69-2791-xx

74-12204-xx

Page 55: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Subwoofer and Speakers

Page 6-7 © 2015 Cisco Systems, Inc. All rights reserved.

Install the four remaining speakers using 4x Black M3 Shoulder Screw 69-2791-xx per speaker. Do not use a power driver when installing the screws to avoid damage to the thread inserts.

4x 74-12204-xx

5

Page 56: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 57: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-1 © 2015 Cisco Systems, Inc. All rights reserved.

Starting Installation and Cabling of the Front Row Table Required Parts Table legs (1x left inside table leg 800-44195-xx, 1x right inside table leg 800-41001-xx, 2x outside table leg 800-41002-xx) Ethernet/Power modules: o 6x Power/Ethernet connectivity modules (part varies by country) o 4x Power/Ethernet connectivity cover 700-47772-xx o 2x Power/Ethernet connectivity blanking plates 700-45421-xx o 20x #4-40 nuts for power/Ethernet connectivity brackets 1x Front Row Cable Management Assembly 800-40845-xx 49-0326-xx 14x M8x16mm screws 69-2792-xx 6x M6 nuts 69-2800-xx 2x Table leg connectors (700-44718-xx right, 700-44719-xx left) 8x M6x10mm screws 69-2803-xx 4x Cosmetic leg brackets (700-46219-xx far right, 700-44754-xx right- center, 700-44755-xx left-center, 700-46218-xx far left) 2x jumper cables 37-0833-xx 1x PoE Switch WS-C2960C-8PC-L 2x switch bracket 700-44758-xx 2x #10-32 screws 69-100184-xx 1x Microphone Connector (MC) 800-40951-xx

Required Tools o #3 and #4 Phillips Driver o 13mm wrench or adjustable wrench o 19mm 12-point ratcheting box end wrench o Metric tape measure or ruler o Spirit level o Laser level o 1/4-inch nut driver or wrench (for Power/Ethernet brackets)

Cables - First Row Table CTS-5K-CBL-R1-SW (69-2669-xx), includes 1x 5 meter Ethernet cable 37-1534-xx CTS-5K-CBL-R1-LAP (69-2671-xx), Ethernet connectivity modules, includes o 1x 5 meter Ethernet cable 37-1561-xx EX1 o 6x 8 meter Ethernet cable 37-1562-xx, C1-C6 CTS-5K-CBL-R1-MIC (69-2674-xx), includes 6x DisplayPort-to- DisplayPort cable, 2.6 meter, 37-1542-xx A1-A6 CTS-5K-CBL-R1-AC 69-2676-xx power cables, includes: 2x Jumper cable, 3 meter, 37-0833-xx D1 and D6 2x Jumper Cable, 2 meter, 37-0994-xx no reference designator - extra jumper cables for middle legs

Velcro cables 52-0449-xx as needed

Page 58: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

Unpack the two table legs 800-41001-xx and 800-44195-xx and make sure that the top plate is correctly installed. If the plates are incorrectly installed, remove the three screws that attach the plate to

the leg, flip it 180 degrees, then re-install it.

Incorrect - Long slot on plate matches with slot on table leg. Remove the three screws, flip plate

180 degrees, and reattach

Correct - Cloverleaf pattern on plate matches with slot

on table leg

800-41001-xx and 800-44195-xx

Page 59: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Turn the 4x table legs (1x each inside table legs 800-41001-xx and 800-44195-xx and 2x outside table legs 800-41002-xx) upside down. Adjust the levelers until there is 1 inch (25mm) between the bottom

edge of the leg and the base of the foot.

25mm (1’’)

4x first row table legs (1x 800-41001-xx, 1x 800-44195-xx & 2x 800-41002-xx)

Page 60: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Align the pins on the front row cable management assembly 800-40845-xx with hole and slot on the inner table legs (800-44195-xx left, 800-41001-xx right). then connect the legs to the assembly using

6x M8x16mm screws 69-2792-xx (3 per leg). Tip: The part number is printed on the underside of the leg.

800-40845-xx

800-44195-xx

800-41001-xx

Find part number here

6x 69-2792-xx

Page 61: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Loosely attach the Cable Runner Bracket to the Front Row assembly by by sliding the slots in the Cable Runner Bracket onto the two M6 studs located on the Front Row Cable Management assembly. Attach

2x M6 nuts 69-2800-xx to the studs finger-tight.

2x 69-2800-xx

Page 62: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-6 © 2015 Cisco Systems, Inc. All rights reserved.

5

Hold the right outside table leg 800-41002-xx and attach the right Table leg connector 700-44718-xx to connect the table leg. Attach the bracket to the table legs using 4x M8x16mm screws 69-2792-xx.

Connect the left table leg 800-41002-xx using the same procedure, using the 700-44719-xx left connector and 4x M8x16mm screws 69-2792-xx.

700-44718-xx

800-41002-xx

4x 69-2792-xx

Right side

700-44719-xx

800-41002-xx

4x 69-2792-xx Left side (as viewed facing the front of system)

Page 63: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-7 © 2015 Cisco Systems, Inc. All rights reserved.

6 Using a laser level, make sure that the outside table legs are level with the inside table legs.

Check table height by aligning these notches on the table legs (inside or outside) with the

diamonds on the endpoint structure

Diamond in center of table assembly aligns with diamond on center of endpoint structure

Page 64: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-8 © 2015 Cisco Systems, Inc. All rights reserved.

7

Insert the cosmetic leg brackets (700-46219-xx far right, 700-44754-xx right-center, 700-44755-xx left-center, 700-46218-xx far left) into the table legs. Use 8x M6x10mm 69-2803-xx screws to attach

these to the table leg brackets (2 screws per bracket).

700-44754-xx 700-44755-xx 700-46219-xx

700-46218-xx

700-46219-xx

8x 69-2803-xx

700-44755-xx

Page 65: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-9 © 2015 Cisco Systems, Inc. All rights reserved.

8

Assemble the power outlets to the outlet covers prior to installation to the table legs. a. Take the 6x Power/Ethernet connectivity modules (part number varies by country) and assemble them to the 4x

Power/Ethernet connectivity cover 700-47772-xx using the #4-40 nuts included with the power/Ethernet module. b. Use the blanking plates 700-45421-xx for the two outside legs as shown and attach using 8x 4-40 nuts 49-0326-xx. Tip: Hold the cover flat and install the nuts from below using a nut driver to facilitate installation.

700-45421-xx

700-47772-xx 1x Power/Ethernet

Modules 8x #4-40 nuts

2x outside legs

2x Power/Ethernet Modules

700-47772-xx

8x #4-40 nuts

2x Inside legs

Page 66: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-10 © 2015 Cisco Systems, Inc. All rights reserved.

9

Install the 4x power/Ethernet connectivity modules to the table legs. Install 3x #4-40 nuts 49-0326-xx to the studs and tighten the nuts. Insert the modules with two outlets into the 2x inside table legs and

insert the modules with one outlet and one blanking plate into the 2x outside table legs.

Assembled power/Ethernet connectivity modules

Page 67: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-11 © 2015 Cisco Systems, Inc. All rights reserved.

10

Connect and route the power and Ethernet cables for the table legs. Insert an extra power (jumper) cable to the outside legs as shown in the picture on the left, and ensure that the inside legs have

room for the cable retractor (installed later) as shown by the yellow outline in the illustration on the right. Note: The extra jumper cable is used in case of failure of the power module - you can replace the module without removing the tabletops.

Outside table legs - insert extra jumper cable and route behind power connector - note jumper connections

clear from yellow dotted area as shown. Inside

Page 68: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-12 © 2015 Cisco Systems, Inc. All rights reserved.

11

Attach the Microphone Connector and the switch to the cable management assembly. a. Connect the 2x switch bracket 700-44758-xx to the POE Switch WS-C2960C-8PC-L with 2x #10-32 screws

69-100184-xx. b. Attach the switch and the Microphone Connector 800-40951-xx to the studs in the cable management assembly using 4x M6 nuts 69-2800-xx. Note the correct orientation of the Microphone Connector, with the single connector facing to the right, and the six connectors facing to the left.

a. 2x 700-44758-xx & 2x 69-100184-xx

800-40951-xx - note six connectors on right and one connector on left

WS-C2960C- 8PC-L

b. 2x 69-2800-xx

b. 2x 69-2800-xx

Page 69: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 7-13 © 2015 Cisco Systems, Inc. All rights reserved.

Starting Installation and Cabling of the Front Row Table

12

Route the cables. Note the reference designators on the cables, and check the cabling diagram to make sure you use the correct cables. a. Route the 6x power cables from the power/Ethernet table leg

modules to the PDU. Use the slots in the cable management assembly to assist in routing. b. Route the 1x power cable from the PoE Switch to the PDU (shown in red). Use Velcro cable wrap 52-0449-xx to manage excess cables. 3. c. Route 1x-6x Ethernet cables from the Ethernet switch to the top of the table (to be used for the 1x - 6x Touch 10 call control devices). Use this switch for the Touch 10 devices only; DO NOT use this switch for the table leg Ethernet connections. d. Route the 1x power cable from the PDU to the cable runner (shown in red). e. Route the Ethernet cables from the power/Ethernet table leg modules to the cable runner (shown in blue). Leave space above the switch for venting. f. Connect the mic bar cables to the Microphone Connector, and route the main Microphone Connector cable through the cable runner. NOTE: The mic bars, Touch 10 device, and presentation cable retractors are installed in a later procedure.

b.

Microphone Connector cables from all mic bars and power/Ethernet from two outside legs - note routing through ca-

ble management slots a. c.

Power/Ethernet cables and presentation cables from two

inside legs

All cables routing down to the cable runner must come from the sides - routing from

the top could interfere with the installation of the cable runner cap d.

e.

Legend: o Green - Microphone Connec-

tor/mic bars o Red - power cables o Blue - Ethernet cables o Orange - presentation cables

Page 70: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 7-14 © 2015 Cisco Systems, Inc. All rights reserved.

Starting Installation and Cabling of the Front Row Table

Additional cabling diagram provided here for clarity. Note that the number of Touch 10 cables will vary, depending on the number of Touch 10 devices (1 to 6 for the first row). Caution: Failure to follow

cabling directions can result in either the parts not fitting correctly, or electrical impedance issues.

Inside leg power/Ethernet cables

Legend: o Green - Microphone Connec-

tor/mic bars o Red - power cables o Blue - Ethernet cables o Orange - presentation cables

Page 71: Cisco TelePresence IX5000 and IX5200 Installation Guide

Starting Installation and Cabling of the Front Row Table

Page 7-15 © 2015 Cisco Systems, Inc. All rights reserved.

Level the system using the laser level, and measure the distance between the outside table legs and the edges of the display stands in the endpoint structure.

1111 mm 1111 mm

13

Page 72: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 8-1 © 2015 Cisco Systems, Inc. All rights reserved.

Installing Endpoint Structure Cables

Cable Routing and Cable Diagrams

Cables - Codec Host CPU codec cabling kit 69-2702-xx:

o 2x DisplayPort-to-DisplayPort cable, 400mm, 72-100828- xx, DP2 and DP3

o 1x DisplayPort-to-DisplayPort cable, 4 meter, 37-1544-xx AX1

o 1x Ethernet cable, 4.27 meter, 37-1546-xx, EX1 o 1x Jumper cable, 2 meter, 37-0994-xx, D22

Encoder/Decoder codec cabling kit 69-2704-xx:

Cables - Woofer Woofer cabling kit 69-2673-xx includes: o Power Cord, 37-1331-xx, D21 o 3.5mm Stereo Jack cable, 37-1539-xx, A28 o USB cable, 37-1538-xx, USB2 o Phone plug-to-terminal cable, 72-5653-xx, A29

42- Inch Display (Optional): o Power and DVI-to-HDMI cable for the display (included with

display), H5 and D27 o 1x USB-to-USB cable, 2 Meter, 37-1538-xx USB1 o o 1x Jumper cable, 2 meter, 37-0994-xx D24

Cables - Speakers, Camera, and Lights Speaker, light and camera cabling kit, 69-2668-xx:

o 3x Light bar cables, 37-100748-xx, L1, L2, L3 o 3x RCA Y cable for speaker 37-1557-xx L4, L4 R&L, L5, L5

R&L, L6, L6 R&L o 1x DisplayPort-to-DisplayPort cable, 2 meter, 37-1547-xx DP1

Note: Firmly connect the DisplayPort cable until it clicks into place.

Page 73: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 74: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 8-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

Install the cabling for the codecs, PDUs, lights, speakers, woofer, and (optionally) the 42-inch display under the three main displays. The next few pages show the cable routing.

See the cable routing diagrams later in this section and at https://www.cisco.com/c/dam/en/us/td/docs/telepresence/ix5000/wiring_diagram/IX5000_WiringDiagram.pdf for the cabling connections. The color-coded designators next to the cable ends (L1, L2, L3, etc.) are shown on the previous page and correspond to the connections on the electrical unit (codecs, PDUs, lights, speakers, and woofer). Be sure to connect these on the correct side (for example, connect the side of the cable with the microphone icon to the microphones, and connect the side of the cable with the MC icon to the Microphone Connectors).

Caution: Do not plug any additional equipment that is not part of the IX5000 or IX5200 system into the PDUs, such as external 55-inch content monitors and document cameras.

NOTE: Since the light bars and camera are not yet installed, prepare these cables for installation using the following procedure:

• Lay the light cables atop the speakers (left, right, and center atop the endpoint structure).

• Lay the camera cable directly in the center of the endpoint structure between the speakers.

Tip: If you need more Velcro straps, cut them crosswise to make double the amount of straps.

Page 75: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 8-3 © 2015 Cisco Systems, Inc. All rights reserved.

Speaker Left PDU and Woofer

Page 76: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 8-4 © 2015 Cisco Systems, Inc. All rights reserved.

Codec cabling (note iPass cable between Encoder/Decoder and Host CPU codecs). Use Velcro cables as required.

Page 77: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 8-5 © 2015 Cisco Systems, Inc. All rights reserved.

Codec and cable runner Power cable in the left-side channel, Ethernet cables in the

right-side channel, Presentation cables in the center channel

Page 78: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-2 © 2015 Cisco Systems, Inc. All rights reserved.

Optional 42-inch display (use this as a guideline only - the cable runner cover will not be installed at this time)

Page 79: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-1 © 2015 Cisco Systems, Inc. All rights reserved.

Required Parts 3x Displays 74-12597-xx

Installing and Cabling the Displays Required Tools o #2 Phillips driver

6x Display Z-clips 3x 700-46232-xx and 3x 700-46233-xx 2x Display mounting spools 69-2625-xx 2x Silver M8 threaded studs 69-2625-xx 2x Silver M8 external tooth lock washers 69-2625-xx 2x Display brackets (no part number, included with the displays) 10x M6 display bracket screws (included with the displays) 2x Vertical bezel extrusions 800-41842-xx 10x M4 X 12mm screws 69-2797-xx 6x M4 X 6mm screws, black, 69-2625-xx Display cabling kit, 69-2678-xx includes the following cables:

o #3 Phillips driver o 13mm wrench or adjustable wrench o 19mm ratcheting box end wrench o Spirit or digital level o Gloves (recommended for display mounting because

the vertical edge of the displays has a sharp edge) o 6mm T-handle hex driver

o 3x power cord, 3 meter, 37-0833-xx o 3x HDMI-to-DVI-D patch cord, 3 meter, 37-1387-xx

Page 80: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

CAUTION: Use care and wear gloves when mounting the displays - the vertical outer edge of the displays has a sharp edge that can cause injury if the display slides through your hands.

NOTE: Display assembly is different than the TX or CTS immersive systems, please read this section carefully before installation and follow all steps in the correct order. Attach the Z-clips to the top of the displays. 700-46232-xx goes on the left side (when viewed from the FRONT of the display) and 700-46233-xx goes on the right. a) insert the 1x M4 X 6mm screw 69-2625-xx into the bracket finger-tight, b) peel off the adhesive tape backing on the bracket, c) press the bracket to the display, and d) tighten the 69-2625-xx screw with a #2 Phillips screwdriver. e) Repeat for all three displays.

700-46233-xx

Install on this standoff (2nd from end) 1x 69-2625-xx

1x 69-2625-xx

700-46232-xx

Page 81: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Install the display brackets (included with the display) to the left and right displays with the 10 M6 screws included with the brackets using a #2 Phillips driver. Install the bracket on the left side for the

left display and install the bracket on the right for the right display. NOTE: For this book, left and right are as viewed from the FRONT of the system, therefore left and right are reversed.

Right display

5x bracket screws

Left display

Page 82: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Insert the spool on the right display. a. remove one M8 screw on the lower right side (when viewed from the FRONT) of the display using a #3 Phillips driver. b. Install a silver M8 lock washer (part of 69-

2625-xx) and an M8 stud (part of 69-2625-xx). c. Tighten the stud with a 13mm wrench. d. Install the spool (part of 69-2625-xx) on the threaded stud. d. MAKE SURE THAT THERE IS 1 1/8 inch (29mm) distance between the spool and the rear of the display or you cannot install the display.

1 1/8’’ (29 mm)

69-2625-xx

Page 83: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing Endpoint Structure Cables

Page 9-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Insert the spool on the left display. The procedure is the same as installing the spool on the right display, but you place the spool on the lower left side (when viewed from the FRONT) of the display, instead of the lower right. Make sure that there is 1 1/8 inch (29mm) distance between the spool and the rear of the display for correct installation of the display.

1 1/8’’ (29 mm)

69-2625-xx

Page 84: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 9-6 © 2015 Cisco Systems, Inc. All rights reserved.

Installing and Cabling the Displays

5a

Temporarily hang the right display onto the frame rail of the structure using the top hooks. Connect the power, DVI, and fan cables. See page C-2 for the connections to the codec and PDU; the fan connects directly to the display. TURN THE DISPLAY POWER SWITCH TO THE ON POSITION.

74-12597-xx

DVI connector

Fan connector Power switch AC connector

Display top hooks Frame rail

Page 85: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 9-7 © 2015 Cisco Systems, Inc. All rights reserved.

Installing and Cabling the Displays

5b

Move the right display into its installed position. Engage the spool in the slot in the frame, place the inner corner of the display on the support bracket, and place the leveling bracket on the leveler.

Note that the display is not supported by the top hooks on the frame rail. CAUTION: Do not pinch your hand between the display and the support bracket.

Slot

Spool

Leveling bracket

Leveler Display

Support bracket View from back

Page 86: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 9-8 © 2015 Cisco Systems, Inc. All rights reserved.

Installing and Cabling the Displays

6a

Temporarily hang the center display using the top hooks and frame rail and rotate the frame out to connect the power, DVI, and fan cables. See page C-2 for the connections to the codec and PDU; the fan connects directly to the display. TURN THE SWITCH FOR THE DISPLAY TO THE ON POSITION.

Cable access from

this side

74-12597-xx

Page 87: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 9-9 © 2015 Cisco Systems, Inc. All rights reserved.

Installing and Cabling the Displays

Move the center display into the display frame. CAUTION: Do not pinch your hand between the display and the support brackets.

Display

Support bracket

6b

Page 88: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing and Cabling the Displays

Page 9-10 © 2015 Cisco Systems, Inc. All rights reserved.

7

Move the left display into its installed position and attach the power, DVI, and fan cables on the rear of the display. See page C-2 for the connections to the codec and PDU; the fan connects directly to the

display. TURN THE SWITCH FOR THE DISPLAY TO THE ON POSITION. CAUTION: Do not pinch your hand between the display and the support bracket.

DVI connector

Power switch & power connector

Slot Spool

View from back Leveling bracket

Leveler

Page 89: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing and Cabling the Displays

Page 9-11 © 2015 Cisco Systems, Inc. All rights reserved.

8

Level the displays and make the left and right displays vertically level with the center display. Use the left and right levelers to create an even gap between the left and center, and center and right,

displays. Use a 6mm T-handle hex driver to turn the leveler from below (it has a socket in the end of the threaded stud). Tighten the lock nut on the levelers after you complete leveling.

Leveling bracket

Leveler

View from back - use a 6mm T-handle hex driver from below to adjust levelers

Page 90: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing and Cabling the Displays

Page 9-12 © 2015 Cisco Systems, Inc. All rights reserved.

Remove the protective film from the displays by pulling the tape off in the directions shown by the arrows.

9

Page 91: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing and Cabling the Displays

Page 9-13 © 2015 Cisco Systems, Inc. All rights reserved.

10

Install the 2x 800-41842-xx vertical bezel extrusions between the displays. a. Insert the extrusion center rib between the left and center displays, and insert the hook into the slot in the center pillar. b.

Insert 4x M4x12 screws 69-2797-xx into the lower part of the extrusions (2x each per extrusion) and tighten the screws with a #2 Phillips driver. Do NOT use a power driver for this procedure and do not overtighten. c. Push the left and right displays from the sides towards the center against the extrusions to take up any gaps. Leave the film on the front of the displays.

Slot 2x 800-41842-xx

Hook 800-41842-xx

2x 69-2797-xx

Page 92: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing and Cabling the Displays

Page 9-14 © 2015 Cisco Systems, Inc. All rights reserved.

11

Check that the system is plumb using a spirit or digital level. Adjust the two outer feet as needed using a 13mm open-end wrench or adjustable wrench on the hex profile above the foot base. Make

sure that all six feet are touching the floor and tighten the locknuts on all six feet using a 19mm ratcheting box wrench.

19mm Lock nut

13mm hex profile nut

Page 93: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-1 © 2015 Cisco Systems, Inc. All rights reserved.

Required Parts Camera: o 1x Camera 74-12203-xx Light Bars:

Installing the Camera and Light Panels Required Tools o #2 Phillips driver

o 1x each left, center, and right light panels (3x 74-12235-xx) o 1x each left, center, and right speaker cover (700-46597-xx, 700-46596-xx, and

700-46595-xx respectively) o 1x each left and right fascia corner braces (700-46598-xx left, 700-46594-xx right) o 8x black M4x12mm screw with external lock washer 69-2797-xx

Page 94: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

a. Attach the camera 74-12203-xx to the vertical structure supports of the endpoint structure. The screws are pre-attached to the camera. b. Attach the DisplayPort Cable to the port at the top of camera

housing.

74-12203-xx

Page 95: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-3 © 2015 Cisco Systems, Inc. All rights reserved.

2 stress on the cable connection

Attach the light panels. a. Connect the cable connectors between the center light panel (part of 74-12235- xx) and the cable between the light bar and codec (already installed in the endpoint structure). Do not put

, as it can break the connection inside the light bar. b. Lift the panel into position and fit the tabs on top of the light panel behind the tabs in the center horizontal crossbar. Do not place the light bar tabs into the crossbar slots. c. Swing the bottom of the light panel inward so it sits on the small shelf on the pillar. Visually center the light panel in the frame. DO NOT allow the panel to fall during this procedure.

a. Light panel cable connector 74-12235-xx

b. Fit light bar tabs behind the crossbar slots - DO NOT place in the crossbar slots

c. Rest on Shelf

DO NOT put stress on the cable at the light panel

Page 96: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-18 © 2015 Cisco Systems, Inc. All rights reserved.

3

Install the center speaker cover 700-46596-xx and attach the cover to the endpoint structure using the 4x captive Phillips screws. The cover fits under the small shelf on the pillar. Be careful to not pinch the

light wire as shown in the below picture.

Do not pinch cable 700-46596-xx

4x Captive Screws

Page 97: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Install the left light panel (part of 74-12235-xx) and left speaker cover 700-46597-xx, then the right light panel (part of 74-12235-xx) and right speaker cover 700-46595-xx using the same procedure as the

center speaker cover and light panel. After installation, make sure that the edges of the panels touch.

74-12274-xx 74-12275-xx

700-46595-xx

700-46597-xx

Page 98: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-6 © 2015 Cisco Systems, Inc. All rights reserved.

5

Install 6x Black M4 X 12mm screws 69-2797-xx into the recessed holes in the speaker covers. Make sure that the screws thread into the threaded holes behind the covers. Install the 2x screws for the left

display first, then 2x center screws, then 2x right. Note: If the screws do not align with the threaded holes, DO NOT place a screwdriver or other object into the hole to align them. Raise or lower the displays using the display levelers from the rear of the system to align the holes.

6X 69-2797-xx

Page 99: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Camera and Light Panels

Page 10-7 © 2015 Cisco Systems, Inc. All rights reserved.

6

Insert the hook of the left fascia corner brace 700-46598-xx into the tab in the horizontal crossbar, then rotate the brace into position and attach the brace to the endpoint structure using 2x M4 screws 69-

2797-xx. Repeat for the right fascia corner brace 700-46594-xx.

2x 700-46594-xx

Hook & Tab

700-46598-xx (left), 700-46594-xx (right)

Tab Hook

Page 100: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Kick Plates

© 2015 Cisco Systems, Inc. All rights reserved.

Required Parts Front kick plates:

Installing the Front Kick Plates Required Tools o #2 Phillips driver

o Left, center, and right front kick plates (700-43097-xx center, 700- 43098-xx left, 700-43096-xx right)

o 1x Cardboard spacer no part number, attached to the cable runner base

o 5x black M4x12mm screw 69-2797-xx

700-43096-xx

700-43097-xx

700-43098-xx

NOTE: Make sure that all cabling between the endpoint structure and the front row table is complete before you install the front kick plates.

Page 11-1

Page 101: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Kick Plates

Page 11-4 © 2015 Cisco Systems, Inc. All rights reserved.

1a

Install the front center kick plate 700-43097-xx. a. Fit the center kick plate to the frame, placing the cardboard spacer under it. b. Attach, but do not tighten, 2x black M4x12mm screws 69-2797-xx into

the center of the slot. Note the arrow that indicates the correct slot for the screw.

2x 69-2797-xx 700-43097-xx Arrow indicates

correct slot

Page 102: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Kick Plates

© 2015 Cisco Systems, Inc. All rights reserved.

1b

c. Place the cardboard spacer between the cable runner and the front kick plate and level the front kick plate using a spirit level. Make sure that the front kick plate is a minimum of 26mm above the

highest point on the floor (either left or right). d. Tighten the 2x black M4x12mm screws 69-2797-xx, remove the spacer, and recheck the minimum 26mm of clearance.

Minimum 26mm (1 inch) Cardboard spacer

Page 11-3

Page 103: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Kick Plates

Page 11-4 © 2015 Cisco Systems, Inc. All rights reserved.

2a

Attach the front left and right kick plates 700-43098-xx and 700-43096-xx. a. Hook the pin on the side kick plates over the alignment notch in the front center kick plate and connect the hooks in the

side kick plate to the retention slots in the center kick plate. Support the free end until the remaining screws are installed. b. Using a spirit level, level the outside edge of the front left kick plate (700-43098-xx) with the front center kick plate. c. Install and tighten 4x black M4x12mm screws 49-0420-xx (2 for each kick plate). Note the arrows on the kick plates that show the correct screw placement.

4x 49-0420-xx

Arrows show correct screw placement

700-43098-xx

Page 104: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Kick Plates

© 2015 Cisco Systems, Inc. All rights reserved.

2b

Install and tighten 1x black M4x12mm screw 69-2797-xx to connect the front left kick panel 700- 43098-xx to the rear kick plate. Re-adjust the rear kick plate to align the screw hole if needed.

Repeat for the right side front kick plate 700-43096-xx.

Page 11-5

69-2797-xx

700-43098-xx 700-43096-xx 69-2797-xx

Page 105: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Installing the Front Row Tabletops

Required Parts 1x each Tabletops A, B, and C (700-42477-xx, 700-42476-xx, and 700- 42478-xx)

8x Biscuit Joiner, 700-23909-xx

4x Half Moon Bolt, M6 x 80mm, 51-6068-xx

4x Joint Plate, 700-23345-xx

48x M8 x 16mm screws, black 69-2792-xx

Required Tools #4 Phillips Screwdriver o 10mm open end or ratcheting wrench

Page 12-1

© 2015 Cisco Systems, Inc. All rights reserved.

Page 106: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

© 2015 Cisco Systems, Inc. All rights reserved.

Lower Table Top Assembly A 700-42477-xx onto the table leg assembly. Do not secure the table to the legs at this time. Repeat this step with Table Top B 700-42476-xx.

Page 12-2

700-42477-xx

1

Page 107: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-15

2

With tabletop assemblies A&B resting on the leg assembly, install x8 biscuit joiners 700-23909-xx (4x per seam) into the slots in the tabletops. Be sure that the biscuit joiners are fully seated in their

slots.

4x 700-23909-xx

700-42477-xx

700-42476-xx

4x 700-23909-xx

Page 108: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Slide table top assemblies A&B together, then slide the table top slightly to the right or left, allowing enough room to install the tabletop hardware from underneath. Make sure that the tops stay on the

table legs and do not fall.

Page 109: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Install 2x half moon bolt assemblies (51-6068-xx) into slots in the bottom of tabletop assemblies A&B. Use 10mm open end or ratcheting wrench to tighten the nuts and bring the table sections together.

Make sure the front and back edges are aligned before tightening, and make sure that the half-moon bolt assemblies are inserted all the way into their recesses in the table.

2x 51-6068-xx

Page 110: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-6 © 2015 Cisco Systems, Inc. All rights reserved.

Install the joint plates 2x 700-23345-xx to the bottom of table top assemblies A&B (700-42477-xx & 700-42476-xx) by inserting 6x 69-2792-xx screws per joint plate.

6x 69-2792-xx 2x 700-23345-xx

5

Page 111: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-7 © 2015 Cisco Systems, Inc. All rights reserved.

12x 69-2792-xx

2x 51-6068-xx

2x 700-23345-xx

Underside of table 700-42478-xx

Table edge

Attach tabletop C 700-42478-xx to tabletops A&B, using the exact same parts, tools, and joining procedures as you used to join tabletops A&B.

700-23909-xx 4x

6

Page 112: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Front Row Tabletops

Page 12-8 © 2015 Cisco Systems, Inc. All rights reserved.

Slide the tabletop assembly into its correct position, then secure it to the table legs using 24x M8x16mm screws (69-2792-xx), 6x screws per table leg. Start from the inside legs, then move outward.

6x 69-2792-xx (3 each side of leg)

7

Page 113: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-1 © 2015 Cisco Systems, Inc. All rights reserved.

Required Parts

Completing Installation of the First Row Table Required Tools

3x mute button 74-12200-xx 3x microphone bars 74-12199-xx Note: The packaging for the mic bar includes the mic bar and the center cap. Do not throw the small round caps away with the packaging. 24x M4x12mm screws 69-2801-xx 6x Mini-DisplayPort Cables Velcro straps 52-0449-xx as needed 2x Presentation cup 800-43264-xx ‘ 8x M3 thumb screws 69-2824-xx 12x M3x12mm screws 69-2815-xx 12x M3 screws 48-0873-xx (part of mute button 800-41388-01)

o #4 Philips Screw Driver o 10mm socket or ratcheting wrench o Flat file or Dremel (for the table leg when installing the

cable retractor) o White gloves (included with accessory kit)

2x Cable retractor 800-42888-xx 8x M3x12mm screws for cable retractor 48-2091-xx 1x Cable runner retainer 700-44724-xx 6x M6x10mm screws 69-2815-xx 1x Cable runner cover (700-42945-xx for systems without 42-inch auxiliary displays, 700-47587-xx for systems with auxiliary displays) Side panel and front panel covers: o 2x 700-43422-xx -- outside of center-left and center-right leg o 2x 700-43004-xx - inside of the outside legs o 2x 700-43424-xx -- outside of outside table legs o 2x 700-43423-xx - inside of inside legs o 1x 700-43425-xx - front (privacy) panel 3x cable mute button covers (1x right 700-44726-xx, 1x left 700-44727-xx, 1x center 700-45410-xx) 13x M4x10mm black screws 69-2821-xx

Page 114: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

a. Lower the Mute Button Assembly 74-12200-xx to the mute button hole on the table top assembly. b. Route the mute button cable through the openings underneath the tabletop to the mic bar hole. c. Secure

the Mute Button Assembly with the 2x M4 x 12mm screws 69-2801-xx. d. Adjust the screws so that mute button is flush with top surface of Table Top Assembly. e. Repeat for each Mute Button Assembly.

a. 3x 74-12200-xx

d. Mute button flush with table after installation

c. 2x 48-2646

b. Mute button cable - route through to mic bar hole

Page 115: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Prepare the microphone (mic) bar assemblies. a. Remove the mic bars and mic bar caps from the cartons. Do not throw away the small round microphone caps that attach to the center of the microphone bars.

Connect the mini-DisplayPort Cables (two for each mic bar) to the connectors on the bottom of the mic bar 74-12199-xx. b. Connect the cables from the mute button to the mic bar. c. Gently rest the connected mic bar upside down on the table. d. Repeat this step for each mic bar. e. Loop excess cable in the cable management assembly as shown. NOTE FOR IX5200 SYSTEMS ONLY: Three mic bars have a red plastic covering and have a red sticker on the underside - use these for the second row and DO NOT install these on the first row.

- Mini-DisplayPort cable for mic bar (6 total)

- Mute button cables (3 total)

IX5200 only: Turnaround mics (74-12552-xx) have a red label on underside - use for second row only - DO NOT USE for first row

a. Mini-DisplayPort cable from table assembly (2

per mic bar) b. Mute button to mic

bar connection

3x 74-12199-xx

Page 116: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-4 © 2015 Cisco Systems, Inc. All rights reserved.

3

Prepare the Ethernet cables for the Touch 10 devices. a. Remove the protective film around the center of the mic bar. b. Take the Ethernet cable(s) (either one or two cables, depending on the number of

Touch 10 devices per segment) from the PoE switch in the front row table and pull them through the holes in the center of the microphone bar until there is approximately 2 1/2 feet (76.2 cm) of free cable through the mic bar hole. c. Attach the microphone bar plug (separately packaged with the mic bar) to the mic bar using 1x M4x12mm screw 69-2801-xx. d. Ensure that the cables are routed under the table so that they will not be pinched when the cosmetic panels are installed. Use Velcro straps as required. e. If your system uses additional Touch 10 devices, repeat steps a. though c. for the right and left mic bar; otherwise, attach the cap to the left and right mic bars without inserting a cable.

Note underside of mic bar cap. Use these grooves to route two

Ethernet cables.

c. 1x Mic bar cap & 1x 69-2801-xx screw

c. Check routing under

the table

a. Remove wrapping around mic bar hole

And use this groove for one cable. One to two cables can be installed per mic bar, for one or two Touch

10 devices per segment.

b. 2 1/2 feet of Ethernet cable (actual color is gray)

Page 117: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-5 © 2015 Cisco Systems, Inc. All rights reserved.

4

Install the mic bars into the table. a. Lower the mic bar assembly towards its recess on the tabletop and pass the mini-DisplayPort cable through the openings in the table top assembly. Make sure that the

wire between the mic bar and the mute button uses the routing as shown in Step 1.b. b. Secure the Mic Bar Assembly to the Table Top Assembly by inserting 6x M4 x 12 mm screws 69-2801-xx from the underside of the table top assembly. Do not use a power driver for these screws. c. Repeat this step for each mic bar assembly.

b. 6x 43-2426-xx

a. Place the cables into the tabletop openings

Page 118: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-6 © 2015 Cisco Systems, Inc. All rights reserved.

5 Route the Mini-DisplayPort cables underneath the table towards the center of the structure.

Page 119: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-7 © 2015 Cisco Systems, Inc. All rights reserved.

6

Check the connections for the 6x mini-DisplayPort cables between the mic bar and the microphone connector (MC). Use Velcro cable wraps as needed to secure cables. Ensure that the cables are held

inside of the structure so as they are not pinched when the cosmetic panels are installed.

Mic bar 6

Mic Bar 2-5

MC1 - to cable runner Mic Bar 1

Page 120: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-8 © 2015 Cisco Systems, Inc. All rights reserved.

7

Connect the Cisco TelePresence Touch 10 device(s) to the PoE switch in the first row table. Use velcro cable wraps as needed to secure cables and ensure that the cables are held inside of the structure so

they are not pinched when the cosmetic panels are installed.

Notes: - You can install up to six Touch 10 devices (one per participant). - Route the cables above the switch so that a minimum amount of hot air is blocked around the heatsink.

Touch 10 device To Touch 10 (1-6 cables depending

on number of Touch 10 devices) These fins on the switch are

heatsinks - route cables so air is not blocked in this area

To cable runner and Host CPU codec

Page 121: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 13-9 © 2015 Cisco Systems, Inc. All rights reserved.

Completing Installation of the First Row Table

8

Install the presentation cups to the table tops. a. Lean the 2x cable retractors 800-42888-xx against the two inside table legs, 1 per table leg (do not place in the table leg yet). b. Insert the triple-headed

presentation cable from the cable retractor through the presentation hole in the table and into the cup 800- 43264-xx. Connect the cup pieces using 6x M3 screws SR6213. Note: If there is not enough free play in the cable, cut the two zip ties (and ONLY these zip ties) as shown in the illustration. c. Place the cable and the cup into the cup base in the Table Top Assembly. d. Secure the cup to the table using 4x M3 thumbscrews SE2587. e. Repeat this procedure for the other cable cup.

800-42888-xx: Cut these zip ties before installation

if there is not enough free play

to insert the cable into the

presentation cup; otherwise cut after

installation

800-42888-xx: NEVER cut this zip tie

Presentation hole in table Underside of table 4x SE2587

6x SR6213 Top of table

Page 122: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-10 © 2015 Cisco Systems, Inc. All rights reserved.

9

Install the cable retractors into the table. a. Place the retractor into the table from the right side of the right-center table leg, and attach it using 4x M3x12mm screws 48-2091-xx. b. Repeat on the left side

for the left cable retractor using 4x M3x12mm screws. d. If you did not do so before, cut the two zip ties for the cable retractor. Route the other presentation cable end through the cable runner to the Host CPU codec.

Retractor: NEVER cut this zip tie

Retractor: Cut these zip ties if you did not cut them yet

Example shows right table leg

4x 48-2091-xx (installed from

other side)

Page 123: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-11 © 2015 Cisco Systems, Inc. All rights reserved.

Install the left and right cable side/mute button covers (right 700-44726-xx, left 700-44727-xx) to the underside of the tabletop assemblies using 8x M4x10mm black screws 69-2821-xx (4 for each side).

700-44726-xx

4x 69-2821-xx

700-44727-xx

10

Page 124: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 13-12 © 2015 Cisco Systems, Inc. All rights reserved.

Completing Installation of the First Row Table

11

Install the 8x side panels to the leg assemblies. Wear the white gloves included in the accessory kit for this step. 700-43422 01 – outside of center-left and center-right leg. 700-43004-xx - inside of

the outside legs. 700-43424-xx – outside of outside table legs, 700-43423-xx- inside of inside legs. Do not install the center panel 700-43425-xx at this time.

700-43424-xx 700-43422-xx 700-43424-xx

700-43004-xx

700-43423-xx

Page 125: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-13 © 2015 Cisco Systems, Inc. All rights reserved.

700-44724-xx

8x 69-2815

11 Install the cable runner retainer 700-44724-xx using 6x M6x10mm black screws 69-2815-xx.

Page 126: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-14 © 2015 Cisco Systems, Inc. All rights reserved.

12

Install the cable runner cover. a. Take cable runner cover 700-42945-xx with holes pointed toward the table legs. Angle the cover towards the endpoint structure and engage the notches on the cover

with the keylock features on the cable runner base. b. Lower the cover onto the cable runner, being careful not to mar or strike the display frame or the front row table top. c. Attach the 2x M6x10mm screws 69-2815- xx to secure the cap to the cable cover. d. If your system includes the optional 42-inch display, route the power and signal cables for the display through the hole in the runner.

c. 2x 69-2815

a. & b. 700-42945-xx

d o

auxill

. (systems with ptional 42-inch iary displays only)

Page 127: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-15 © 2015 Cisco Systems, Inc. All rights reserved.

13

Install the front panel. Align the tabs located on the mounting rails on the inner side of the Front Panel 700-43425-xx to the slots located on the front cable management panel. Move the panel slightly up

and over the legs, then move it into position.

700-43425-xx

Page 128: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-16 © 2015 Cisco Systems, Inc. All rights reserved.

Install and secure the cable center/mute button cover 700-45410-xx to the underside of the tabletop assembly using 5x M4x10mm black screws (69-2821-xx).

5x 69-2821-xx

700-45410-xx

14

Page 129: Cisco TelePresence IX5000 and IX5200 Installation Guide

Completing Installation of the First Row Table

Page 13-17 © 2015 Cisco Systems, Inc. All rights reserved.

Measure from the sides of the table to the sides of the endpoint structure. Both sides should be aligned and even with the structure.

15

Page 130: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 131: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-1 © 2015 Cisco Systems, Inc. All rights reserved.

Required Parts

Installing the Second Row Table (IX5200 Only) Required Parts Cont’d

7x Table legs (1x far left leg 800-44198-xx, 1x far right leg 800-44197-xx, 5X inside legs 800-44200-xx) 21x M8x16MM screws 69-2802-xx 6x each Back row cable management assembly, left and right (3x 800-42717- xx and 3x 800-42715-xx) 2x switches WS-C2960C-8PC-L 4x switch bracket 700-44758-xx 2x microphone connector (MCs) 800-40951-xx 2x Power distribution units (PDUs) 74-8655-xx 12x M6 nuts 49-100235-xx 4x #10-32 pan head screws 69-2818-xx 7x Metal trim pieces (700-103477-xx left corner, 700-103476-xx right corner,

Tabletops (700-45242-xx far right, 700-45239-xx far left, 700-103970-xx second from right, 700-103971-xx second from left, 700-45241-xx mid-right, 700-45240- xx mid-left) 20x Biscuit joiner, 700-23909-xx 10x Half moon bolt, M6X80MM, 51-6068-xx 10x Joint plate, 700-23345-xx 102x M8x16mm screws, black 69-2802-xx Mute button covers (3x 700-45426-xx, 3x 700-45427-xx) 24x M4x10mm black screws 69-2817-xx 14x leg PET panels (2x outside panels 700-43424-xx, 6x right inside panels 700- 43426-xx, 6x left inside panels 700-43427-xx 6x front panel covers (3x 700-43502-xx, 3x 700-43005-xx

700-45431-xx outside-left, outside right, and center, 700-45430-xx inside-left Velcro cable straps 52-0449-xx as needed and inside-right) Ethernet/Power modules: o 12x Power/Ethernet connectivity modules (part varies by country) o 7x Power/Ethernet connectivity cover 700-47772-xx o 2x Power/Ethernet connectivity blanking plates 700-45421-xx o 28x #4-40 nuts for power/Ethernet connectivity brackets 62x M4x12mm screws 69-2801-xx 30x M4 countersunk screw 69-2817-xx 1x downspout kit (includes short round piece 700-46612-xx, long flat piece 700-46613-xx, 3x M4x10 screws 69-2817-xx, and 3x M6x10mm screws 69- 2803-xx) 6x Mute button assembly 74-12200-xx 12x M6x10mm screws 69-2803-xx 3x Microphone bars 74-12199-xx* 3x Turnaround microphone bars 74-12552-xx* * The packaging includes the mic bar and the center cap. Do not throw the small round caps away.

Required Tools o #4 and #2 Philips screwdrivers o 7mm & 10mm socket o 7mm Allen driver or wrench o 10mm ratcheting wrench or socket o Laser level

Required Cables 69-2833-xx cabling kit, includes the following subkits: 69-2670-xx, includes 2x Ethernet cables 37-1558-xx and 37-1534-xx, EX2 and EX3 69-2672-xx, includes 13x Ethernet cables 37-1558-xx C7-C18, CX2 69-2675-xx (mic bar and mute button), includes: o 2x DisplayPort-to-DisplayPort cables, 12 meter, 37-1541-xx, MC2 and MC3 o 12x Mini-DisplayPort-to-Mini-DisplayPort cables, 2.6 meters, 37-1542-xx, A7-

A18 69-2677-xx, includes 3x Jumper Cord, 2 meter, 37-0994-xx

Page 132: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-2 © 2015 Cisco Systems, Inc. All rights reserved.

Preinstallation requirement: Plan for trenching for cables in the room using the following diagram.

THERE IS FLEXIBILITY IN POSITION. SHOULD NOT BE UNDER PRODUCT (TRENCHES ARE FOR SECOND ROWONLY)

5.500 [139.7]

5.500 [139.7]

(60 ) [1520] (60 )

[1520]

125 [3185]

125 [3185]

5 [125]

128 [3260]

128 [3260]

5 [125] SCALE 1/20

5 [125]

5 [125]

Page 133: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-3 © 2015 Cisco Systems, Inc. All rights reserved.

1

Turn the 7x table legs (1x far left 800-44198-xx, 1x far right 800-44197-xx, 5x inside legs 800-44200- xx) upside down. Adjust the levelers until there is 1 inch (25mm) between the bottom of the leg and the

base of the foot.

25mm (1’’)

Page 134: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-4 © 2015 Cisco Systems, Inc. All rights reserved.

2

Make a note of the table legs and assemblies used for the cable management panels that go between the legs, and be sure to assemble these panels in the correct order. NOTE: This is shown from the front,

so right and left are reversed.

800-44198-xx

800-42715-xx 800-44197-xx

5x 800-44200-xx (all inside legs)

800-42717-xx

Page 135: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-5 © 2015 Cisco Systems, Inc. All rights reserved.

3

Connect the far-right cable management assembly 800-42715-xx to the far-right table leg 800-44197- xx and the second-from right table leg 800-44200-xx by inserting 6x M8x16mm screws 69-2802-xx

into each leg.

6x 69-2802-xx

800-44200-xx

800-42715-xx

800-44197-xx

Page 136: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-6 © 2015 Cisco Systems, Inc. All rights reserved.

Continue to build the table from the right to the left, alternating cable management assemblies and using the same attachment procedures. Save the far-left table leg 800-44198-xx until the very last step. Keep the structure centered behind the first row table, and use the measurements in the next slide to Tip:

keep it the correct distance from the first row table.

800-42715-xx

800-42717-xx

800-44198-xx

4

Page 137: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-7 © 2015 Cisco Systems, Inc. All rights reserved.

1535 mm 1535 mm

Measure the distance between the 1st and 2nd row table legs and center the system relative to the front row.

1542 mm

1542 mm

Align the center of the center table leg with the center of the mute button on the front

row table

5

Page 138: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-8 © 2015 Cisco Systems, Inc. All rights reserved.

6

Install the 2x switches WS-C2960C-8PC-L, 2x MCs 800-40951-xx, and 2x PDUs 74-8655-xx. a. Connect the 2x switch bracket 700-44758-xx to the switch with 2x 10-32 screws 69-2818-xx. b. Attach

the 2x switches, 2x MCs, and 2x PDUs to the structure using 12x M6 nuts 49-100235-xx.

2x 800-40951-xx 2x WS-C2960C-8PC-L

12x 49-100235-xx 2x 74-8655-xx 2x 700-44758-xx

Page 139: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-9 © 2015 Cisco Systems, Inc. All rights reserved.

2x 69-2801-xx

700-103477-xx 2x 69-2801-xx

700-45430-xx

700-45430-xx 700-45430-xx 700-45431-xx

700-45431-xx

700-103477-xx

7

Install the metal trim pieces onto the outside table legs (700-103477-xx left corner, 700-103476-xx right corner, 700-45431-xx outside-left, outside-right and center, 700-45430-xx inside-left and inside-right)

using 14x M4x12mm 69-2801-xx screws. reversed.

NOTE: This drawing is shown from the front - left and right are

700-45431-xx 700-103476-xx

Page 140: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-10 © 2015 Cisco Systems, Inc. All rights reserved.

8

Check the level in the vertical and horizontal axis using a laser level. Use the leveling feet to raise or lower the legs. Check the height of the second row relative to the first row by removing the outer panels

on the first row table legs and aligning the horizontal notches on the outer first and second row table legs.

Align this notch on the outer second row table legs with

the same notch on the outer first row table legs

Page 141: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-11 © 2015 Cisco Systems, Inc. All rights reserved.

9

Assemble the power outlets to the outlet covers. a. Take the 12x Power/Ethernet connectivity modules (part number varies by country) and assemble them to the 7x Power/Ethernet connectivity cover 700-

47772-xx using the 4-40 nuts included with the power/Ethernet module. b. Use 2x blanking plates 700- 45421-xx for the two outside legs as shown.

700-45421-xx

700-47772-xx 1x Power/Ethernet

Modules 8x 4-40 nuts

2x outside legs

2x Power/Ethernet Modules

700-47772-xx

8x 4-40 nuts

5x Inside legs

Page 142: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-12 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

10

Install the 7x power/Ethernet connectivity modules to the table legs. Install 3x #4-40 nuts to the studs and tighten the nuts. Insert the modules with one outlet and one blanking plate into the two outside table legs. Add one additional jumper cable to each table leg (to facilitate any replacement procedure).

Insert extra jumper cable and route behind power connector - note jumper connections

Assembled power/Ethernet

connectivity modules

Page 143: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-13 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

11 Perform all cabling for the second row, including the following: • Mute button cables • Mini-DisplayPort cables for the mic bars. Note: Use the correctly-numbered cables for the mic bars

and match the cable numbering to the numbering on the MCs. Use the cabling diagram for complete information.

• 12x Ethernet cables for the 12 Ethernet participant laptop connections

• 12x power cables for the 12 power connections for participants

Page 144: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-14 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

Cable Routing, Left

Page 145: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-15 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

Cable Routing, Center

Page 146: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-16 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

Cable Routing, Right

Page 147: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-17 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

12

Determine the exit point for the cables (on the right or the left of the system). Bundle the cables into the short round piece of the downspout 700-46612-xx from the left or right exit point. Connect

this piece to the long flat piece 700-46613-xx using 6x M4x10mm screws 69-2817-xx. Then connect the assembled downspout to the far-right or far-left table leg using 3x M6x10mm screws 69-2803-xx. Note: There are four holes in 700-46613-xx in which 700-46613-xx may be mounted. If the round piece is too close to the floor, slide it up and use the top three holes. Tip: Install the downspout so that the tapered area points toward the exit path for the cables. Note: If you use non-standard trenching between the endpoint structure and the second row table, be sure that all cables can reach their intended electronic components from one side of the table. If you have difficulty, two cable downspout sets are provided; you can route cables from both sides of the table.

6x 69-2817-xx. Choose one of two mounting points using the four holes in

700-46613-xx

700-46613-xx

700-46612-xx Tapered edge points toward exit path for cables

3x 69-2803-xx (not shown, installed from back of system)

Page 148: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-18 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

Cable Routing For the Downspout

Page 149: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-19 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

13

Install the table tops. Install the right three sections, then the left three sections, then put the sections together. Use the table joiners, half moon bolts, and joint plates, the same as the first row.

Tip: There are letters on the edges of the table. Match the letters on the underside of the tables to build the table correctly.

Numbering on table edges

700-45241-xx 700-45240-xx 700-103970-xx 700-103971-xx

700-45242-xx 700-45239-xx

Page 150: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-20 © 2015 Cisco Systems, Inc. All rights reserved.

74-12199-xx

74-12552-xx 74-12199-xx 74-12552-xx

74-12552

14

Install the 6x mute buttons 74-12200-xx and 6x microphone (mic) bars (3x 74-12552-xx and 3x 74-12199-xx) using 48x M4x12mm screws 69-2801-xx. See Chapter 13 for the steps. If your second row has Touch 10 devices, install them to switches now. Do not throw away the small round microphone caps that attach to the center of the microphone bars. Note that you install 3x regular mic bars, and 3x turnaound mic bars. Turnaround mic bars have a red label on the underside.

6x 74-12200-xx

-xx

Turnaround mics 74-12552- xx- note red label on

underside

Page 151: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-21 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

15

Install the leg PET panels and the front panel covers. Place the PET panels over the magnets on the side of the table legs until they stick into place. Secure the front panel covers to the cable

management assemblies using 12x M6x10mm screws 69-2803-xx.

3x 700-43005-xx

3x 700-43502-xx

12x 69-2803-xx

700-43424-xx 700-43424-xx

6x 70 0-43427-xx - left inside 6x 700-43426-xx - right in side

Page 152: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 14-22 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Second Row Table (IX5200 Only)

Attach the mute button covers to the underside of the second row table to the underside of the tabletop assemblies using 4x M4x10mm black screws 69-2817-xx for each cover.

Page 14-22 © 2015 Cisco Systems, Inc. All rights reserved.

3x 700-45426-xx 3x 700-45427-xx

24x 69-2817-xx

16

Page 153: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Second Row Table (IX5200 Only)

Page 14-23 © 2015 Cisco Systems, Inc. All rights reserved.

17

Measure the distance between the 1st and 2nd rows and adjust the tables as required. Use a laser level down the center of the table, and the seams between the table sections, to line it up with the

first row table. Perform a final height check and make sure that the first and second row tables are the same height.

Laser level

1412 mm

1408 mm 1408 mm

Page 154: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-24

Installing the Outer Structure Panels and Trim

Required Parts 3x upper cabinets (center 800-41092-xx, right 800-41093-xx, left 800- 41094-xx) 2x upper trim joints 700-43281-xx 2x lower cabinet (right 800-41095-xx, left 800-41096-xx) 4x plastic washers for lower right and left cabinets 69-2842-xx 8x black M4x12mm long screw with external lock washer 69-2797-xx 1x each bottom trim pieces (800-42208-xx left, 800-41301-xx center, 800-41302-xx right) Bottom trim joint assembly: o 2x 700-102967-xx (bottom trim plate) o 2x 700-47507-xx (narrow bottom trim joint) o 2x 700-47506-xx (medium bottom trim joint) o 2x 700-47505-xx (wide bottom trim joint)

Required Tools #2 Phillips Driver Spirit level White gloves 69-2795-xx (for handling the top and bottom fascia and rear PET panels)

o 2x M4 nuts 69-2793-xx 18x black M4x12mm long screw with external lock washer 69-2797-xx 1x horizontal display trim (includes 1x trim 800-42131-xx, 2x pin 700- 47278-xx, and 2x clip 52-100131-xx) 1x each top and bottom fascia (74-12905-xx top, 74-13021-xx bottom) Camera lens hood 800-43478-xx 4x rear PET plastic panels: left 800-41100-xx, right 800-41099-xx, top 800-41097-xx and bottom 800-41098-xx Rear cable runner cover 700-43380-xx

Page 155: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 156: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

Install the center cabinet 800-41092-xx. a. Make sure that there is no space between the displays, and push them together if required. b. Lift the center cabinet over the frame and lower the cabinet down

onto the center horizontal cross bar. c. Line up the guide blocks pointing down from the cabinet into the horizontal cross bar. d. Reach back behind the center cabinet to make sure the guide pin sticking out of the frame is fully engaged in the slot in the cabinet and the magnets are mated to the frame.

Guide block

800-41092-xx

Installed center cabinet (from back of system)

Slot (engages with guide pin)

Page 157: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-3 © 2015 Cisco Systems, Inc. All rights reserved.

2a

Install the upper left and upper right cabinets. a. Lower the right cabinet 800-41093-xx onto the horizontal cross bar, fitting the guide blocks of the cabinet into the slots in the cross bar. Make sure the

cabinet is as far to the outside as possible to allow installation of the trim joint. b. Place the trim joint 700-43281- xx into the right and center cabinet aluminum extrusions. c. Slide the cabinet towards the center and engage the guide pins on the side of the frame with the notches in the cabinet. Tip: Reach under the cabinets to feel the notches in the cabinet that match with the guide pins in the frame. If the cabinet does not install correctly, check the following areas: 1. The trim joint is connecting to the trim. 2. The guide pins in the frame align with the notches in the cabinet. 3. The lap joint overlaps correctly between the side and center cabinets.

b. 700-43281-xx

Lap joint

Guide pins

c.

a. 800-41093-xx

G uide blocks and slots

Back of system

Page 158: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-4 © 2015 Cisco Systems, Inc. All rights reserved.

2b

e. Repeat for the upper left cabinet 800-41094-xx. f. Adjust the cabinets so that there are no gaps between the upper cabinets and the trim joints, and make sure that the cabinets are fully seated into

the structure. Tip: If you cannot eliminate the gaps, make the gaps even on both sides.

800-41094-xx

Page 159: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-5 © 2015 Cisco Systems, Inc. All rights reserved.

3a Install the lower corner cabinets (800-41096-xx left, 800-41095-xx right).

800-41096-xx 800-41095-xx

Page 160: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 15-6 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Outer Structure Panels and Trim

3b

b. Loosen, but do not remove, the 4x black M4 X 16mm screws on the lower cabinet sheet metal brackets 800-41095-xx (2x screws for each side) so that there is some movement in the bracket.

c. Place the lower cabinets into position. Fit the tab with the trim in the upper cabinet. Place the lower part of the cabinet between the kick plate and toe cap so that the two magnets on the cabinet attach to the endpoint structure. d. Place a plastic washer 69-2842-xx over 8x black M4x12mm long screws 69-2797-xx, then install the screws with washer through the cabinet brackets and into the endpoint structure. Do not use a power driver to tighten these screws. Tighten them so that some movement of the cabinet is allowed but it can hold its position.

Right

Wrong

c. View from rear - place cabinet between kick plate and toe cap

c. Connect magnets to structure

b. Loosen these 2x screws in the cabinets

c. Align tab with slot

d. 4x 69-2797-xx & 69-2842-xx

Page 161: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 15-7 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Outer Structure Panels and Trim

3c

Place a level on the front of the lower cabinets to align the cabinets both verically, and to line them up with the displays. After you complete this alignment, tighten the 4x screws (2x in each place)

shown in the circles in the illustration. Note that these screws are hidden.

Page 162: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 15-8 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Outer Structure Panels and Trim

4a Install the bottom trim pieces.

800-42208-xx

800-41301-xx

800-41302-xx

Page 163: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 15-9 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Outer Structure Panels and Trim

4b

Install the right bottom trim piece 800-41302-xx. a. Loosen the Phillips screws on the four brackets on the trim piece so that the bracket can move easily, but cannot lift off the flat trim piece. b. Align

the right side bottom trim assembly to the cabinet, lifting up from below to align with the metal trim that is already assembled to the bottom cabinet. c. Install, but do not overtighten, 2x Black M4 X 12mm screw with external lock washer 69-2797-xx at the far right and left of the bottom trim.

800-41302-xx

a. Loosen screws on all four brackets so that bracket can be adjusted c. 2x 69-2797-xx

Page 164: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-10 © 2015 Cisco Systems, Inc. All rights reserved.

4c

d. Level the bottom right trim assembly with a spirit level. e. Add 2x additional Black M4 X 12mm screws 69-2797-xx and tighten the 4x screws. Note: The trim is very flexible. Take care during

installation that it does not move or bend in the middle, thus throwing off the level.

2x 69-2797-xx

Page 165: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-11 © 2015 Cisco Systems, Inc. All rights reserved.

4d

Install the left side trim piece 800-42208-xx by using the same procedure as you did for the right trim piece. After assembly, level and align the left and right trim pieces. Slide the trim pieces

outward (to the sides) to close the gap with the trim on the lower cabinets.

800-42208-xx

Page 166: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-12 © 2015 Cisco Systems, Inc. All rights reserved.

4e

Install the center bottom trim piece 800-41301-xx by raising it upward. Verify that it is level with the left and right bottom trim assemblies using the spirit level. Install and tighten 4x Black M4 X

12mm long screws with external lock washer 69-2797-xx. Tighten all trim pieces.

4x 69-2797-xx

800-41301-xx

Page 167: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-13 © 2015 Cisco Systems, Inc. All rights reserved.

Insert the 2x bottom trim plates 700-102967-xx (one between the left and center trim assembly, and one between the right and center trim assembly) into the trim assemblies.

2x 700-102967-xx

5

Page 168: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-14 © 2015 Cisco Systems, Inc. All rights reserved.

6a

Install the horizontal display trim 800-42131-xx. Remove the foam from the corners of the packaging and connect the metal hinges of the horizontal display trim using the 2x pin 700-47278-xx

and 2x clip 52-100131-xx (1 on each side).

2x 700-47278-xx

800-42131-xx

2x 52-100131-xx

Page 169: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-15 © 2015 Cisco Systems, Inc. All rights reserved.

6b

Caution: Use two people for this procedure. The rubber trim is fragile and must be handled with care to prevent tearing or permanently damaging the trim. Partially unfold the trim, and place the pin

on the left of the trim into the hole on the left side of the endpoint structure.

Hole

Pin

800-42131-xx

Trim-viewed from back

Page 170: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-16 © 2015 Cisco Systems, Inc. All rights reserved.

6c

Still using two people, connect the pins in the trim to the hole between the left and center displays until the studs, magnets, and Velcro attach, then attach the trim to the Velcro, magnets, and studs

between the center and right displays.

800-42131-xx

Attachment points

Studs

Page 171: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-17 © 2015 Cisco Systems, Inc. All rights reserved.

Place the pin in the horizontal display trim into the hole in the endpoint structure. Adjust the trim until both sides are even.

Hole

800-42131-xx

Pin

Trim-viewed from back

6d

Page 172: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-18 © 2015 Cisco Systems, Inc. All rights reserved.

7

Align the display to the cabinet trim. Rotate the spools on the lower back of the displays to align the upper cabinet trim with the horizontal display trim and display on the side (vertical) axis. Perform this

alignment for both the left and right displays.

Display spools Left upper

cabinet trim

Horizontal display trim

Left display

Left vertical trim

Page 173: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-19 © 2015 Cisco Systems, Inc. All rights reserved.

8a

Install the bottom fascia 74-13021-xx. Use two people and wear the gloves that are included with the accessory kit for this procedure. a. Lay the fascia on the ground between the display structure

and the table structure and move the sides of the bottom fascia towards the table. This procedure aids in stability while you assemble the bottom fascia, but still allows you to swing the fascia sides back to the display structure.

74-13021-xx

a. View from top of system

Page 174: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-20 © 2015 Cisco Systems, Inc. All rights reserved.

Note the fascia alignment points in the display structure: The alignment lip that runs along the bottom and sides of the bottom fascia, and the brackets with frame slots in the endpoint structure.

Frame slots for alignment lip and magnets in bottom fascia

Endpoint Structure

Vertical alignment lip in bottom fascia

74-13021-xx

8b

Page 175: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-21 © 2015 Cisco Systems, Inc. All rights reserved.

c.

8c

b. Rest the hooks (3x) in the bottom fascia into frame slots on the display structure, rotating the bottom fascia up into position. c. While leaving the fascia only partially unfolded, insert the alignment

tabs in the left-center of the bottom fascia into the slots in the center display structure to position the bottom fascia in the horizontal direction. As the tabs find the slots and fully engage into the display structure, you can feel and hear the magnets in the fascia attach to the structure.

Slot engages with tab - note round magnets on fascia

74-13021-xx

Bracket engages with hook

Page 176: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-22 © 2015 Cisco Systems, Inc. All rights reserved.

d. Unfold the bottom fascia, one side at a time, and insert the tabs in the side receiving slots until the magnets in the fascia engage with the display structure.

8d

Page 177: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-23 © 2015 Cisco Systems, Inc. All rights reserved.

9

Perform final alignment of the lower outer panels. While still wearing gloves, pull the corners of the fascia out and move the lower cabinet(s), if required, to fit with the fascia and the trim pieces connecting

to it. The aluminum trim should look seamless around the perimeter of the system, and any gaps should be minimal and uniform. The four circled screws with plastic washer should provide adequate movement without loosening the screws. Tighten the screws and replace the fascia after final adjustment.

Page 178: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page 15-24 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Outer Structure Panels and Trim

10

Reach under the fascia and test-fit the 2x bottom trim joints between the lower right and lower left trim assemblies. Use the trim joint that fits best (narrow 700-47507-xx, medium 700-47506-xx, or wide

700-47505-xx) to match the gap between the trim assemblies. Secure with 2x M4 nuts 69-2793-xx. You can mix and match the trim joints (for example, wide on one side and narrow on the other side) to accommodate for varying gaps. You do not need to remove the fascia to attach the trim joints.

Fascia removed in this illustration for clarity

2x 700-47507-xx, 700-47506-xx, or 700-47505-xx - choose the one that

fits best between the gaps

2x 69-2793-xx

Page 179: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

11a

Install the top fascia 74-12905-xx. Use two people and wear the gloves that are included with the accessory kit for this procedure. a. Begin to unfold, but do not fully unfold, the top fascia. Align the

camera cutout in the fascia with the camera, and place the top fascia over the camera. Engage the alignment lip of the fascia to the receiving slots above the center display, and make sure that the magnets connect the fascia to the frame. b. Align the top fascia vertically. The upper lip of the top fascia rests in the sheet metal shelf in the display frame that is created by the horizontal cross bars.

74-12905-xx

Page 15-25 © 2015 Cisco Systems, Inc. All rights reserved.

Frame shelf

Page 180: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-26 © 2015 Cisco Systems, Inc. All rights reserved.

c. Unfold the top fascia one side at a time, engaging the magnets and sheet metal tabs with the upper alignment points in the fascia.

11b

Page 181: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-27 © 2015 Cisco Systems, Inc. All rights reserved.

Install the camera lens hood 800-43478-xx around the camera by placing it into the holes in the upper fascia and the endpoint structure.

800-43478-xx

12

Page 182: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

13

Install the top and bottom center PET panels. Wear gloves during this procedure. a. Install the bottom center PET panel 800-41098-xx. This procedure can be done by one person if there is

enough space between the panels and the wall; if not, two installers are required. Engage the sheet metal hooks in the panel to the slots in the frame and gently press downward to make sure that the panel is fully seated. b. With an assistant, install the top center PET panel 800-41097-xx, engaging the sheet metal hooks in the panel to the slots in the frame and making sure that the panel is fully seated.

800-41097-xx

800-41098-xx

Page 15-28 © 2015 Cisco Systems, Inc. All rights reserved.

Page 183: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Outer Structure Panels and Trim

Page 15-29 © 2015 Cisco Systems, Inc. All rights reserved.

14

c. While still wearing gloves, install the right PET panel 800-41099-xx, and left PET panel 800-41100- xx, using the same procedure you used for the center PET panels. Then place the rear cable runner

cover 700-43380-xx over the rear of the cable cap, noting the pins on the rear part of the cover.

700-43380-xx

800-41100-xx

800-41099-xx

Page 184: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-30 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Optional 42-Inch Auxiliary Display

Required Parts o 42-inch display, 43-100147-01 o 42-inch display bracket, 700-47588-xx o 8x M6x16mm screws, 69-100199-xx o Optional: 1x M4x12mm screw (not included)

Required Tools o #3 Phillips Driver o ‘‘Stubby’’ (short) #3 Phillips driver, or Phillips driver

with ratcheting wrench

Page 185: Cisco TelePresence IX5000 and IX5200 Installation Guide
Page 186: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-2 © 2015 Cisco Systems, Inc. All rights reserved.

1

a. Remove the display bracket 700-47588-xx from its packaging. b. Lay the bracket on the ground, and lift the side with tab upward and outward to separate the two pieces. Tip: there is a hole in the top of the

bracket, press in this hole with your thumb to separate the two pieces. Some force may be required.

Page 187: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-3 © 2015 Cisco Systems, Inc. All rights reserved.

2

Connect the lower half of the bracket piece to the cable runner using 4x M6x16mm screws 69-100199-xx. Note the cables running through the hole in the bracket. Take care not to mar the lower fascia or the cable

runner.

69-1

4x 00199-xx

Page 188: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-4 © 2015 Cisco Systems, Inc. All rights reserved.

Remove the display from its packaging, and install the other half of the bracket onto the rear of the display using 4x M6x16mm screws 69-100199-xx.

3

Page 189: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page A-5 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Optional 42-Inch Display

4

a. Move the cables away from the display bracket. b. Carry the display with the bracket to the bracket you attached to the cable runner, and slide the display bracket onto the cable runner bracket. Be careful to not

mar the cable runner. Tip: there are four metal studs (two on each side) that protrude from the display bracket. Make sure that the studs go into the two slots on each side of the cable runner bracket.

b.

Studs

Slots

Slots (hidden here)

a.

Page 190: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page A-6 © 2015 Cisco Systems, Inc. All rights reserved.

Installing the Optional 42-Inch Display

5

a. Connect the power and DVI cables to the display. b. Turn the power switch (near the cable connections) for the display to the On position, and watch for the power LED to turn green, then blinking

amber. c. Rock the display and bracket backwards until the tab in the display bracket joins with the slot in the cable runner bracket.

b.

Power s witch

Power LED

c.

DVI and power connectors

a.

Page 191: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-7 © 2015 Cisco Systems, Inc. All rights reserved.

6

Level the display in relation to the fascia and the rest of the system. Rock back the display to separate the two pieces (some force might be required). Loosen the four screws that hold the display to the display

bracket. The display pivots on the top right screw. Rotate the display and tighten the screws after the display is level. Note the use of a “stubby” screwdriver. A Phillips driver and a ratcheting wrench may also be used.

Stubby screwdriver or Phillips driver with ratcheting wrench

Br on

cket pivots this screw

a

Page 192: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Optional 42-Inch Display

Page A-7 © 2015 Cisco Systems, Inc. All rights reserved.

7 Optional: Attach an M4x12mm screw (not included) to join the brackets together.

M4 screw (not shown)

Page 193: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket

Page B-1 © 2014 Cisco Systems, Inc. All rights reserved.

Required Parts

Installing the Seismic Bracket Required Tools

Seismic Bracket Kit 69-100167-xx, including: o 6x drill template 78-100395-xx o 6x anchor bracket 700-46833-xx o 2x 1/2-inch drill bit 51-101126-xx (Kit # 69-100214-xx) o 2x 3/8-inch drill bit 51-101125-01 (Kit # 69-100214-xx) o 12x 3/8 x 2.75 inch Strong-Bolt 2 51-101201-xx (Kit # 69-100257-xx) o 12x 3/8 x 1.5 inch drop-in anchor 51-101122-xx (Kit # 69-100210-xx) o Anchor setting tool 51-101124-01 (Kit # 69-100234-xx) o 12x 3/8 x 1 inch hex head cap screw 48-101180-xx (Kit # 69-100209-xx) o 24x 3/8 inch washer 48-100249-xx o 4x reinforcing bracket 700-46832-xx (Kit # 69-100213-xx) o 24x M8x16mm screws 48-3012-xx (Kit # 69-100208-01) o 12x 3/4 inch hex nut 49-100247-xx (Kit # 69-100212-xx) o 12x 3/4 inch washer 49-100246-xx (Kit # 69-100211-01)

o #3 Phillips Driver o Power drill o 1 1/8 inch or 29mm open-end or box-end wrenches or

adjustable wrenches o Torque wrench with 75 foot-pound (102 N-m) or greater

capacity o 9/16 inch or 15mm socket o Measuring tape o Compressed air source (canned compressed air is

acceptable) to clean the holes after drilling

Note: Installing the seismic brackets adds time to the overall installation. Be sure to budget additional time when planning and preparing the overall installation of your system.

THE SEISMIC BRACKETS HAVE BEEN DESIGNED TO MEET THE REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE (IBC) 2012 and CALIFORNIA BUILDING CODE (CBC) 2013. IT IS CRITICAL THAT THE SEISMIC BRACKETS ARE ANCHORED IN ACCORDANCE WITH ALL NATIONAL, REGIONAL AND LOCAL BUILDING CODES, AND YOU MUST ENSURE THAT YOU USE THE CORRECT ANCHOR TYPE FOR THE SURFACE ON WHICH THE PRODUCT WILL BE MOUNTED. THE SUPPLIED ANCHORS ARE ONLY SUITABLE FOR CERTAIN SURFACES. PLEASE READ THE INSTALLATION GUIDE VERY CAREFULLY AND WORK WITH A LICENSED DESIGN PROFESSIONAL AND FACILITIES OR BUILDING MANAGER. CISCO DISCLAIMS ALL RESPONSIBILITY FOR ANY DAMAGE RESULTING FROM FAULTY ANCHORING OF THE SEISMIC BRACKETS.

Page 194: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket - IX5000

Page B-2 © 2014 Cisco Systems, Inc. All rights reserved.

The seismic brackets, when installed as directed, are IBC 2012 and CBC 2013 code compliant and can be installed at any site with an Sds=2.5 and z/h=1 for the following installation conditions:

• Slab on Grade: Use 3/8” diameter Simpson Strong-Bolt 2 with an embedment depth of 2” (5.08 cm) at a concrete compressive strength of 3,000 psi (20.7 MPa) or greater with a slab thickness of 3.5” (8.85 cm) or greater in each of the (12) anchorage attachment locations.

• Top of Concrete over Metal Deck Floor or Roof: Use 3/8” diameter Simpson Strong-Bolt 2 with an embedment depth of 2.75” (6.99 cm) at a concrete compressive strength of 3,000 psi (20.7 MPa) or greater with a slab thickness of 4.5” (11.4 cm) or greater in each of the (12) anchorage attachment locations.

Note: We also ship a drop-in anchor (51-101122-xx) as an alternative method to secure the seismic brackets to the floor. While installations using these anchors will not be IBC or CBC code compliant, they are included for installations where using the Strong-Bolt 2 is not feasible.

Page 195: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket

Page B-3 © 2014 Cisco Systems, Inc. All rights reserved.

1

Mark the drilling locations for the anchor brackets. a. Assemble the lower display frames and place the frames into their final installation position in the room. b. Place the 6x drill templates 78-100395-xx on

the floor under the holes shown in the illustration, then place the 6x anchor brackets 700-46833-xx over the templates and into the holes in the frame. c. Align the templates with the anchor brackets and tape the templates to the floor so they do not move. d. Remove the anchor brackets and display frames, leaving the templates.

6x 700-46833-xx

6x 78-100395-xx

Lower Righ t fr ame Lower left frame

Page 196: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket - IX5000

Page B-4 © 2014 Cisco Systems, Inc. All rights reserved.

Anchor Bracket Drilling Location (not to scale)

Page 197: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket

Page B-5 © 2014 Cisco Systems, Inc. All rights reserved.

Perform one of the steps on the following pages, depending on the type of anchor you use (Strong-Bolt 2 or drop-in anchor). 2

Page 198: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page B-6 © 2014 Cisco Systems, Inc. All rights reserved.

Installing the Seismic Bracket

Installing the Seismic Bracket

Strong-Bolt 2 procedure: Do not use an impact wrench to set or tighten the Strong-Bolt 2 anchor. Caution: Oversized holes in the base material will make it difficult to set the anchor and will reduce the anchor’s load capacity. a. Drill a hole in the base material using 3/8-inch drill bit 51-101125-01. Drill the hole to the depth required for the installation condition (see page C-2 for requirements and work with a licensed design professional and building or facilities manager to evaluate these requirements). Remove the drill templates. b. Blow it clean using compressed air. Overhead installations need not be blown clean. Alternatively, drill the hole deep enough to accommodate minimum hole depth and dust from drilling. c. Assemble the anchor with nut and washer so that the top of the nut is flush with the top of the anchor. Insert the anchor through the 700- 46833-01 bracket slot and drive into the hole until washer and nut are tight against the bracket. Note that you torque these bolts to an installation torque of 30 ft/lb (40.7 n-m) later in this procedure.

a. b. c. d.

Page B-6 © 2014 Cisco Systems, Inc. All rights reserved.

6x 700-46833-xx

51-101201-xx

51-101125-xx

Page 199: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page B-7 © 2014 Cisco Systems, Inc. All rights reserved.

Drop-in anchor procedure: a. Drill a hole using the 1/2-inch drill bit 51-101126-xx a minimum of 1 5/8 inches (41mm) deep, then blow the hole clean using compressed air. Remove the templates. b. Insert the anchor into the hole until the top of the anchor is flush with the surface. c. Using the anchor setting tool 51-101124-xx, drive the anchor into the ground until the shoulder of the setting tool makes contact with the top of the anchor. d. Place the anchor brackets 700-46833-xx over the anchors, then insert the 12x 3/8 x 1-inch hex head cap screws 48-101180-xx with washers 48-100249-xx into the anchors. Leave the cap screws loose at this point.

a. b. c.

d.

12x 48-101180-xx & 48-100249-xx 6x 700-46833-xx

51-101124-xx 51-101122-xx

51-101126-xx

Page 200: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket - IX5000

Page B-8 © 2014 Cisco Systems, Inc. All rights reserved.

3

a. Thread a 3/4-inch hex nut 49-100247-xx with washer 49-100246-xx onto each anchor bracket. Screw them down enough to provide vertical clearance for the frame. b. Place the lower frames over the anchor

brackets.

6x 49-100247-xx & 49-100246-xx Lo

lowe f

wer l r ce ram

eft & nter e

Lowe & lo

f

r cen wer ri ame

ter ght

Page 201: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page B-9 © 2014 Cisco Systems, Inc. All rights reserved.

4

a. Attach 4x reinforcing brackets 700-46832-xx to the display frames using 6x M8x16mm screws 48- 3012-xx per bracket. Tighten the screws using a #3 Phillips driver. b. Install 1x washers 49-100246-xx

and 1x hex nut 49-100247-xx for each bracket. Leave the nuts loose at this point. They will be tightened after the displays have been installed and the system is plumb. c. Tighten the 12x bolts (for Strong-Bolt 2 installations) or screws (for drop-in anchor installations) that connect the brackets to the floor with a 9/16-inch (15mm) wrench. Repeat for the remaining 5 brackets. d. Strong-Bolt 2 only: Tighten the bolts to an installation torque of 30 ft/lb (40.7 n-m).

c.& d.

b. 6x 49-100247-xx & 49-100246-xx (1 each per anchor bracket)

a. 4x 700-46832-xx & 6x 48-3012-xx

Page 202: Cisco TelePresence IX5000 and IX5200 Installation Guide

Installing the Seismic Bracket - IX5000

Page C-2 © 2015 Cisco Systems, Inc. All rights reserved.

After the display frames are level and plumb, tighten the 3/4 inch nuts using two 1 1/8-inch (29mm) wrenches or adjustable wrenches. Make sure that the nut under the frame is tight as well.

49-100247-xx - make sure that nuts above and below the frame

are both tight.

5

Page 203: Cisco TelePresence IX5000 and IX5200 Installation Guide

Cable Routing Diagrams

This chapter includes the cable routing diagrams for the system.

Page 204: Cisco TelePresence IX5000 and IX5200 Installation Guide

Page C-2 © 2015 Cisco Systems, Inc. All rights reserved.

Cable Routing Diagrams

Page 205: Cisco TelePresence IX5000 and IX5200 Installation Guide