    Cisco FabricPath Design Guide:

    Using FabricPath with anAggregation and Access Topology

    December, 2011

    For further information, questions and comments please contact [email protected]

    Design Guide

  • 7/27/2019 Cisco Fabric Path-690079

    2/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 2 of 5

    Introduction.............................................................................................................................................................. 3

    Hardware and Software Support ............................................................................................................................ 3Next-Generation Data Center Architecture............................................................................................................ 4FabricPath Technology Overview .......................................................................................................................... 7

    Spine and Edge ................................................................................................................................................... 8Switch-ids ............................................................................................................................................................ 9Conversational Learning.................................................................................................................................. 11VLAN Trunking.................................................................................................................................................. 11Metrics ............................................................................................................................................................... 11Multipath Load Balancing ................................................................................................................................ 12Multidestination Trees...................................................................................................................................... 12Multicast Forwarding........................................................................................................................................ 14vPC+................................................................................................................................................................... 14

    Design Considerations for the Spine/Aggregation Layer ..................................................................................14Topology Considerations................................................................................................................................. 16

    Declaring VLANs as FabricPath VLANs ..................................................................................................... 16Declaring Ports as FabricPath Ports .......................................................................................................... 17Topology 0 .................................................................................................................................................... 17Unicast Layer 2 Multipathing ...................................................................................................................... 17

    Building a Routed Spine .................................................................................................................................. 17F1 and M1 Card Cooperation ...................................................................................................................... 17M1 Card Routing Traffic............................................................................................................................... 18F1 Card Architecture and MAC Optimization............................................................................................. 18MAC Scalability Considerations ................................................................................................................. 20

    Gateway Routing............................................................................................................................................... 22Active/Active Gateway Routing................................................................................................................... 22Benefits of vPC+ at the Spine ..................................................................................................................... 24Dual-Active Exclude (Peer-Link Failure).................................................................................................. 24

    Connecting FabricPath Edge or Leaf Layer to the Spine Layer....................................................................25Avoiding Flooding by Tuning ARP and Layer 2 Table ................................................................................... 25Multicast Routing Considerations................................................................................................................... 25

    Multicast Forwarding in FabricPath ........................................................................................................... 26Routed Multicast Configuration.................................................................................................................. 26Routed Multicast with vPC+ ........................................................................................................................ 27

    Summary Recommendations...........................................................................................................................28Design Considerations for the Edge and Access Layer .................................................................................... 28

    FabricPath VLANs............................................................................................................................................. 29MAC Learning at the Access Layer ................................................................................................................. 29Learning the HSRP MAC Address ................................................................................................................... 29Direct Connectivity between Edge Switches.................................................................................................. 30vPC+ at the Edge .............................................................................................................................................. 30Integration with FEX .........................................................................................................................................32Summary............................................................................................................................................................ 33

    FabricPath Scalability Considerations ................................................................................................................ 33FabricPath Convergence Times ...........................................................................................................................37Sample Configurations .........................................................................................................................................38

    Cisco Nexus 7000 Series Spine 1 (DC1-Agg1) ...............................................................................................38Cisco Nexus 7000 Series Spine 2 (DC1-Agg2) ...............................................................................................42Edge Cisco Nexus 5500 Switch (DC1-5500-1) without vPC+ ........................................................................ 46

  • 7/27/2019 Cisco Fabric Path-690079

    3/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 3 of 5

    Edge Cisco Nexus 5500 Switch (DC1-5500-1) with vPC+ and FEX A/A ....................................................... 47Edge Cisco Nexus 5500 Switch (DC1-5500-2) with vPC+ and FEX A/A ....................................................... 50

  • 7/27/2019 Cisco Fabric Path-690079

    4/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 5

    Introduction

    The introduction of Cisco

    FabricPath technology in Cisco NX-OS Software Release 5.1(3) brings the benefit of

    routing protocols to Layer 2 network Ethernet environments. Cisco FabricPath technology is described in several

    documents available on the cisco.com page:

    http://www.cisco.com/en/US/prod/switches/ps9441/fabric_path_promo.html

    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/at_a_glance_c45-605626.pdf

    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/white_paper_c11-605488.html

    http://www.cisco.com/en/US/docs/switches/datacenter/sw/5_x/nx-

    os/fabricpath/configuration/guide/fp_cli_Book.html

    The advantages of using FabricPath include:

    MAC address scalability with conversational learning

    Spanning Tree Protocol independence: No reliance on Spanning Tree anymore. Each switch has a

    complete view of the Layer 2 topology, and it calculates the Layer 2 forwarding table based a shortest-path-

    first calculation.

    Traffic distribution for unicast: Unicast Layer 2 traffic can take multiple equal-cost Layer 2 paths.

    Traffic distribution for multicast on multiple distribution trees: Multicast traffic can be distributed along

    two multidestination trees.

    More direct communication paths: Any topology is possible, so cabling two access or edge switches

    directly to each other creates a direct communication path, unlike what happens with Spanning Tree.

    Simplicity of configuration: The configuration of FabricPath is very simple. Tuning may still be advised

    but by default the switches negotiate switch-ids allocation with a protocol called Dynamic Resource

    Allocation Protocol (DRAP).

    Loop mitigation with TTL in the frame field: Layer 2 loops, as they are known of today in Spanning-

    Tree-Protocol-based Layer 2 networks, are mitigated by dropping frames that have been propagated

    across too many hops. The Layer 2 FabricPath frames include a Time to Live (TTL) field that is

    decremented at each hop. The value of the TTL field is 32.

    This document describes one of many possible designs that are enabled by Cisco FabricPath, and it includes

    tuning recommendations and sample configurations.

    Hardware and Software Support

    The solution described in this document requires the following hardware and software:

    Cisco Nexus

    5500 products as the edge (or access) device in a FabricPath topology with NX-OS Software

    Release 5.1(3)N1(1). Note that in the context of FabricPath domain, the edge device is also known as the

    leaf device.

    Cisco Nexus 7000 Series products as the spine (or aggregation) device in a FabricPath topology with NX-

    OS 5.1(1) Release or later. At the time of this writing, the Cisco Nexus 7000 Series configuration that

    enables FabricPath is based on the F1 series cards, which consist of 32 ports 1/10 Gbps. The Layer 3

    functionality is provided by the use of M1 series cards.

    http://www.cisco.com/en/US/docs/switches/datacenter/sw/5_x/nx-os/fabricpath/configuration/guide/fp_cli_Book.htmlhttp://www.cisco.com/en/US/docs/switches/datacenter/sw/5_x/nx-os/fabricpath/configuration/guide/fp_cli_Book.htmlhttp://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/white_paper_c11-605488.htmlhttp://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/at_a_glance_c45-605626.pdfhttp://www.cisco.com/en/US/prod/switches/ps9441/fabric_path_promo.html
  • 7/27/2019 Cisco Fabric Path-690079

    5/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 5

    Cisco Nexus Fabric Extenders (FEX) platforms are supported with the FEX ports acting as FabricPath edge

    ports. FEX can be used to augment the number of edge ports or Classic Ethernet (CE) ports without adding

    configuration points.

    Proper licensing: You need the ENHANCED_LAYER2_PKG license installed. For details, visit:

    http://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/licensing/guide/Cisco_NX-

    OS_Licensing_Guide_chapter1.html.

    Note: The F1 cards are complemented by M1 card for routing purposes. When using M1 cards in the same

    virtual device context (VDC) as the F1 card, routing is offloaded to the M1 cards, and more routing capacity is

    added to the F1 card by putting more M1 ports into the same VDC as the F1 card.

    This design guide refers to the following FabricPath features:

    FabricPath Shortest-Path-First-based forwarding

    FabricPath Layer 2 multipathing (Unicast traffic) FabricPath multidestination trees load balancing (unknown unicast, broadcast, and multicast traffic)

    Active/Active gateway routing using vPC+ configuration

    vPC+ at the edge switch for the purpose of connecting dual-homed servers or dual-homed Cisco Fabric

    Extenders

    Next-Generation Data Center Architecture

    The introduction of FabricPath enables a variety of Layer 2 topologies that were not possible before. Figure 1

    illustrates some of them.

    Figure 1. FabricPath enables new topologies

    http://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/licensing/guide/Cisco_NX-OS_Licensing_Guide_chapter1.htmlhttp://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/licensing/guide/Cisco_NX-OS_Licensing_Guide_chapter1.html
  • 7/27/2019 Cisco Fabric Path-690079

    6/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 5

    On the top-left of Figure 1 (topology a), you see a design where two spines connect to a set of edge devices,

    which looks more like an aggregation/access design. However, in contrast to designs based on Spanning Tree

    Protocol, any two endpoints can take all available paths via either spine.

    The second design, topology b at the top-right, illustrates a topology where servers connect to edge devices in

    vPC mode, which in the case of FabricPath is called vPC+.

    The left-bottom design, topology c, illustrates the ability for FabricPath to use multiple spines instead of just two.

    This gives a very granular control on the available bandwidth: the more spines you add, the lower oversubscription

    between the edge and the rest of the network.

    The bottom-right design, topology d, illustrates the ability for FabricPath to provide direct connectivity between

    edge devices in case direct communication between any edge devices is suitable. Most of these topologies would

    not make sense with Spanning Tree, but they are almost plug-and-play topologies in a FabricPath environment.

    Note: Direct connectivity between the spine devices is not strictly necessary. It depends on where the routing is

    performed and on whether you consider it necessary to establish a direct communication path between spines,

    whether spines are just used for fabric switching or are used for end node attachment too, and so on.

    Figure 2 illustrates the traffic paths that any two given servers can take across a Cisco FabricPath topology:

    Figure 2. Traffic paths in FabricPath designs

  • 7/27/2019 Cisco Fabric Path-690079

    7/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 5

    The Layer 3 demarcation point can be placed in several ways, but a very simple deployment model is to place the

    Layer 3 boundary at the aggregation point where all edge or access switches are aggregated. Figure 3 illustrates

    adding the routing function at the spine layer for the FabricPath cloud to connect to the rest of the network

    infrastructure:

    Figure 3. Placing the Router at the Spine Layer

    When placing the routing at the spine, the spine keeps switching Layer 2 traffic based on the switch-id, but it also

    becomes an edge for routed traffic. Yet another option to place the routing function is to connect the routers as an

    edge device to the spine. This approach ensures that the spine switches traffic exclusively based on switch-id, and

    it makes changes to the spine configuration very rare. Figure 14 illustrates this design. Analyzing this last design

    option is outside of the scope of this document.

    In this design guide, the focus is on a topology that uses two spines and multiple edges. The reason for this is that

    its an easy transition for customers who are deploying Spanning Tree today and want to benefit from FabricPath

    without having to rewire their data center. In addition, it is easy to add additional spines in case you want to lowerthe oversubscription ratio, without any substantial change to the design considerations that are the subject of this

    document.

  • 7/27/2019 Cisco Fabric Path-690079

    8/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 5

    Figure 4 describes the topology used in this design guide:

    Figure 4. Topology used in this design guide

    If you want, you can add ports to this design by adding Cisco Fabric Extenders (FEX), as shown in Figure 5:

    Figure 5. Adding FEX to a FabricPath topology

    FabricPath Technology Overview

    This section provides an overview of FabricPath but it is not meant to be a tutorial on the technology. Several

    other white papers already exist on the Cisco public webpage that cover this topic.

    The reason that FabricPath is almost a plug-and-play protocol, in contrast to several other technologies available

    in the market, is that it enables each device to build an overall view of the topology in a way that is similar to Open

    Shortest Path First (OSPF) protocol and other link state protocols.

  • 7/27/2019 Cisco Fabric Path-690079

    9/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 5

    Each device in the topology is identified by a switch-id and all Layer 2 forwarding tables are built based on

    reachability to each switch-id (as opposed to reachability to a MAC address). The switch-id is dynamically

    assigned via the Dynamic Resource Allocation Protocol (DRAP), so no manual allocation of switch-ids is required.

    However, it is possible to manually assign a SW-ID while a dynamic check for misconfiguration is performed (as

    discussed in the Switch-ids section).

    FabricPath multipath forwarding relies on building a view of the network using a Link State Routing Protocol similar

    to the one used in Layer 3 networks. This is achieved with a Layer 2 protocol based on Intermediate-System-to-

    Intermediate-System (IS-IS) routing, which doesnt require any Layer 3 capability on the FabricPath switching

    devices.

    Spine and Edge

    In FabricPath topologies, there are two types of functions (which can be performed by all FabricPath hardware):

    Edge (or leaf) devices: These devices have ports connected to Classic Ethernet devices (servers, firewalls,

    router ports, and so on) and ports connected to the FabricPath cloud (or FabricPath ports). Edge devices

    are able to map a MAC address to the destination switch-id.

    Spine devices: These devices exclusively interconnect edge devices. Spine devices switch exclusively

    based on the destination switch-id.

    Figure 6. Classic Ethernet ports in a FabricPath topology

    Traffic from edge ports is looked up in the Layer 2 forwarding table, and encapsulated into the MAC-in-MAC frame

    whose destination switch-id is the switch that the destination host is attached to. This allows sending traffic along

    multiple paths with the same end-to-end total cost and provides the ability to construct practically any topology and

    be sure that traffic will take the most direct path (lowest cost) between any two devices.

  • 7/27/2019 Cisco Fabric Path-690079

    10/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 5

    Switch-ids

    In order to understand these concepts, lets consider the topology in Figure 7:

    Figure 7. Example switch-id allocation

    The following CLI capture from an edge device shows the output of the show fabric switch-id command. The

    output shows all the switch-ids present in the topology, and it highlights with a * the switch-id of the device that theuser is on:

    DC1-5500-1# show fabricpath switch-id

    FABRICPATH SWITCH-ID TABLE

    Legend: * - this system

    =========================================================================

    SWITCH-ID SYSTEM-ID FLAGS STATE STATIC EMULATED

    ----------+----------------+------------+-----------+--------------------

    *111 0005.73d4.9141 Primary Confirmed Yes No

    112 0005.73fc.2001 Primary Confirmed Yes No

    113 0005.73fc.207c Primary Confirmed Yes No

    121 0022.5579.d3c1 Primary Confirmed Yes No

    122 108c.cf18.0941 Primary Confirmed Yes No

    The edge switch maintains a MAC address table with the mapping of MAC address to switch-ids as well as the

    local source MACs from its CE ports, as illustrated here:

    DC1-5500-1# show mac address-table vlan 101

    Legend:

    * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC

    age - seconds since last seen,+ - primary entry using vPC Peer-Link

    VLAN MAC Address Type age Secure NTFY Ports

    ---------+-----------------+--------+---------+------+----+------------------

    * 101 0000.0700.0000 dynamic 0 F F Eth1/5

    * 101 0000.0700.0100 dynamic 10 F F 112

    * 101 0022.5579.d3c1 dynamic 10 F F 121

    * 101 108c.cf18.0941 dynamic 0 F F 122

    As you can see from the output, the locally attached MAC addresses are associated with the local port. The

    remote MAC addresses are associated with the switch-id of the destination.

    On the spine devices, there is no MAC address table learning, so the forwarding table is purely switch-id-based. In

    the following example, you can see each switch-id and which port can be used to reach the destination:

    FabricPath Unicast Route Table for Topology-Default

  • 7/27/2019 Cisco Fabric Path-690079

    11/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 11 of 5

    0/121/0, number of next-hops: 0

    via ----, [60/0], 3 day/s 08:11:51, local

    1/111/0, number of next-hops: 1

    via Eth8/3, [115/40], 0 day/s 06:15:55, isis_fabricpath-default1/112/0, number of next-hops: 1

    via Eth8/5, [115/40], 3 day/s 08:09:17, isis_fabricpath-default

    []

    Figure 8 illustrates how traffic is forwarded from MAC address A to MAC address B in a Cisco FabricPath

    topology:

    Figure 8. FabricPath forwarding

    Notice how the switch-id values are assigned by default to each FabricPath device via the DRAP protocol.

    However, it may be good practice to manually assign them in order to provide a more meaningful numbering

    scheme. In this latter scenario, a specific check is performed every time a new switch-id value is configured on a

    given FabricPath node, in order to prevent you from configuring a duplicate switch-id within the same domain.

    However, if two FabricPath switches from two different and isolated FabricPath domains converge into a single

    FabricPath domain, a mechanism intervenes to resolve conflicts:

    DC1-5500-1# 2011 Aug 17 15:32:57 DC1-5500-1 %$ VDC-1 %$ fabricpath %FABRICPATH-2-FABRICPATH_LINK_BRINGUP_STALLED_STATIC: Link bringup stalled due to conflicts

    DC1-5500-1# show fabricpath conflict all

    ====================================================

    Fabricpath Port State Table

    Port State

    ---------------+-------------------------+----------

    port-channel2 Suspended due to conflicts

    ==============================================

    Fabricpath Conflicts

    SYSTEM-ID SWITCH-ID STATIC

    ---------------+--------------+---------------

    0005.73d4.9141 3 Yes

    108c.cf18.0941 3 Yes

  • 7/27/2019 Cisco Fabric Path-690079

    12/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 12 of 5

    Conversational Learning

    Edge switches learn MAC addresses only if they have a node connected on the edge port or if the switch is a

    remote MAC and is in active conversation with a known MAC address connected to an edge port. In other words,a simple flood of traffic (either unknown unicast or broadcast) from a remote switch is not going to populate the

    MAC address table of an edge switch.

    VLAN Trunking

    In spanning tree networks, the user has to specify which VLANs belong to which port by using the switchport

    trunk allowed vlan command. With FabricPath, the user doesnt need to explicitly specify which VLANs are

    carried on a FabricPath-enabled link (VLANs obviously must be defined on the switches).

    The configuration of a FabricPath core port is performed with the command switchport mode fabricpath. The

    command switchport mode trunk puts a port into Classic Ethernet mode instead of FabricPath mode.

    MetricsThe preferred path to any switch-id is calculated based on the metric to any given destination. The metric is as

    follows:

    1-Gbps Ethernet links have a cost of 400

    10-Gigabit Ethernet links have a cost of 40

    20-Gbps have a cost of 20

    Figure 9 illustrates the use of the linkcost in a real topology:

    Figure 9. Metrics calculation in FabricPath

    The following code shows the cost of fabricpath links from the switch 112 from Figure 9.

    DC1-5500-2# show fabricpath isis interface br

    Fabricpath IS-IS domain: default

    Interface Type Idx State Circuit MTU Metric Priority Adjs/AdjsUp

    --------------------------------------------------------------------------------

    Ethernet1/1 P2P 1 Up/Ready 0x01/L1 1500 40 64 1/1

    Ethernet1/2 P2P 2 Up/Ready 0x01/L1 1500 40 64 1/1

    Ethernet1/11 P2P 3 Up/Ready 0x01/L1 1500 400 64 1/1

    Multipath Load Balancing

    Figure 10 illustrates unicast load balancing in a FabricPath network:

  • 7/27/2019 Cisco Fabric Path-690079

    13/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 13 of 5

    Figure 10. Unicast load balancing in FabricPath

    In this example, each edge device has two equal-cost-path routes to each others spine:

    DC1-5500-2: show fabricpath route:

    1/113/0, number of next-hops: 2

    via Eth1/1, [115/80], 3 day/s 19:36:09, isis_fabricpath-default

    via Eth1/2, [115/80], 0 day/s 18:40:16, isis_fabricpath-default

    The load balancing is based on fields such as the IP address, Layer 4 port, and so on, and it is configured with the

    following command:

    DC1-5500-2(config)# fabricpath load-balance unicast < destination, include-vlan,layer-3, layer4, mixed, source, source-destination>

    Multidestination Trees

    In FabricPath multicast traffic, broadcast and flooded traffic is forwarded along a multidestination tree. FabricPath

    allows for multiple multidestination trees in order to achieve traffic load balancing for multidestination frames. This

    is achieved by using a special Tag present in FabricPath frames, which is called Forwarding Tag or FTag.

    The FTag, together with the type of the frames destination address (unknown unicast, broadcast, or multicast),

    selects a forwarding graph, which is the set of possible switches and interfaces along which the frame is

    forwarded. At each switch, the FTag carried in the frame header is used to forward the frame along the interfaces

    that are in the forwarding graph.

    FabricPath uses a link state protocol to determine the forwarding trees in the network. FabricPath technology

    allows the definition of multiple topologies.

    At the time of this writing, only one topology is supported, in which there are two multidestination trees. As Figure

    11 illustrates, two FTags are used: FTag1 and FTag2. In this example, each one of these multidestination trees is

    rooted at one of the spines.

  • 7/27/2019 Cisco Fabric Path-690079

    14/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 14 of 5

    Figure 11. FTag trees assignment in FabricPath

    FTag1 is used for the first multidestination tree and FTag2 is used for the second multidestination tree. FTag trees

    are used as follows:

    FTag1 is used for unknown unicast, broadcast, and multicast. The highest priority switch in the FabricPath

    topology is chosen as the root for FTag1. As discussed later in the guide, it is possible to modify the default

    FabricPath root priority value in order to place the root for FTag1 or FTag2 on a given device in a

    deterministic fashion. If the default priority is maintained on all the switches as part of the FabricPath

    domain, the switch system-id value is used as a tiebreak to determine the switch with the highest root

    priority.

    FTag2 is used only for multicast traffic. The second highest priority switch in the FabricPath topology is

    chosen as the root for FTag2.

    Here are the factors, in order, that are used in order to elect the root for FTag1 and subsequently for FTag2:

    Highest root priority

    Highest system-id Highest switch-id

    Figure 12 illustrates the forwarding of flooded frames along the FTag1 tree:

    Figure 12. Forwarding of unknown unicast and broadcast frames

  • 7/27/2019 Cisco Fabric Path-690079

    15/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 15 of 5

    Multicast Forwarding

    Multicast traffic forwarding uses FTag trees based both on load balancing of multicast frames and on tree pruning

    that is governed by Internet Group Management Protocol (IGMP) snooping (platform-specific load-balancing

    methods are discussed in the design sections of this guide). The edge device performs IGMP snooping and the

    member reports are conveyed in FabricPath via the Group-Membership Link State Protocol (GM-LSP). IGMP

    snooping and IS-IS work in conjunction to build per-VLAN multicast group-based trees in the FabricPath network.

    vPC+

    A virtual PortChannel (vPC) allows links that are physically connected to two different Cisco Nexus switches to

    appear as a single PortChannel to a third device. This provides a loop free topology eliminating the spanning-tree-

    blocked ports and maximizing the bandwidth usage. In a FabricPath network, a host or legacy (not FabricPath-

    enabled) Ethernet switch can be connected through a port channel to two FabricPath edge switches by using a

    configuration construct called emulated switch. The emulated switch implementations in FabricPath, where two

    FabricPath edge switches provide a vPC to a third-party device, is called vPC+.

    Emulated switch is a construct in which two FabricPath switches emulate a single switch to the rest of the

    FabricPath network. The packets originated by the two emulated switches are sourced with the emulated switch-

    id. The other FabricPath switches are not aware of this and simply see the emulated switch (identified by a

    dedicated switch-id value) as reachable through both switches. This means that the two emulated switches have

    to be directly connected via peer link, and there should be a peer-keepalive path between the two switches to form

    the vPC+.

    Other than the fact that a peer-link is used to synchronize MAC addresses between vPC+ peers, the peer-link is a

    regular FabricPath link, and as such it can be used by orphan ports for direct communication.

    The following list provides the reference terminology for vPC+ components:

    vPC+: The functionality enabled on two independent upstream devices to make them appear as a single

    logical device to the downstream switches, allowing the establishment of PortChannel connections. All the

    MAC addresses learned from devices locally attached to downstream devices are advertised to the

    FabricPath domain as connected to the defined emulated switch.

    vPC+ peer device: One of a pair of devices that are connected with the special port channel known as the

    vPC+ peer link.

    vPC+ peer link: The link used to synchronize states between the vPC+ peer devices. Both ends must be

    on 10 Gigabit Ethernet interfaces.

    vPC+ domain: This domain is formed by the two vPC+ peer link devices. It is also a configuration mode for

    configuring some of the vPC+ peer link parameters.

    vPC+ peer-keepalive link: The peer-keepalive link, a Layer 3 link between the vPC+ peer devices, is used

    to ensure that both devices are up. The peer-keepalive link sends periodic keepalive messages between

    the vPC peers on an out-of-band path.

    vPC+ member port: Interface that belongs to the vPC+.

    Design Considerations for the Spine/Aggregation Layer

    The specific topology discussed and validated in the context of this design guide consists of a pair of spine

    devices connected to multiple edge devices. Cisco Nexus 7000 Series platforms are used as spine devices,

    whereas Cisco Nexus 5500 Switches are connected at the edge.

  • 7/27/2019 Cisco Fabric Path-690079

    16/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 16 of 5

    The spine in this design is also used to perform the routing function between the FabricPath cloud and the rest of

    the network. The default gateway for the servers is located in the spine layer, which, being also the router in the

    topology, performs the function of an edge in FabricPath. At the time of this writing, the Cisco Nexus 7000 Series

    hardware combination that provides this capability consists of F1 cards (spine function) together with the M1 cards

    (routing function).

    In the topology shown in Figure 13, the spine layer, which is also an aggregation layer since it aggregates multiple

    edge switches, operates simultaneously in two modes:

    It forwards Layer 2 traffic between the edge devices exclusively based on the destination switch-id, without

    the need to learn MAC addresses (east-to-west traffic).

    It also learns MAC addresses exclusively for the purpose of encapsulating routed traffic into FabricPath

    frames (north-to-south traffic).

    Figure 13. Layer 3 Aggregation/Spine

    These two behaviors are completely independent, in that even if, as a theoretical example, the 128-K adjacency

    table of the M1 card fully filled up, the E-W Layer 2 traffic would still be forwarded based on the switch-id and not

    flooded.

    Compared with a spanning-tree design or a vPC design, this design includes the following advantages:

    Ease of configuration

    Multipath forwarding for unicast and multicast Layer 2 and Layer 3 traffic

    Faster convergence times

    Loop mitigation thanks to the use of a Time to Live (TTL) field in FabricPath frames

    The focus of this section is on the design of this hybrid Layer 2/Layer 3 spine/aggregation layer. This is not the

    only possible design option. For instance, you can also add Layer 3 to an edge switch and use the spine as a pure

    Layer 2 spine, or connect a pair of Layer 2 edge switches to dedicated routing devices, as highlighted in Figure

    14. It is outside of the scope for this document to discuss these specific design options further.

  • 7/27/2019 Cisco Fabric Path-690079

    17/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 17 of 5

    Figure 14. Fabricpath design with separate L3 edge

    Topology Considerations

    FabricPath technology allows building multiple logical topologies on the same physical topology. At the time of this

    writing, this functionality has not yet been enabled by the software, so you should not attempt to create additional

    topologies besides the default topology 0.

    Declaring VLANs as FabricPath VLANs

    All VLANs that are meant to be forwarded according to Cisco FabricPath rules must be created as FabricPath

    VLANs.

    A VLAN needs to be explicitly configured for Classic Ethernet (CE) mode or for FabricPath mode. By default, all

    VLANs are in CE mode. These CE VLANs are not brought up on FabricPath core links. They can be forwarded on

    the FabricPath edge ports locally or to other Classic Ethernet switches.

    The command required to configure a VLAN in FabricPath mode is:

    DC1-Agg1(config)# vlan 101

    DC1-Agg1(config-vlan)# mode fabricpath

  • 7/27/2019 Cisco Fabric Path-690079

    18/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 18 of 5

    The FabricPath VLANs are forwarded on FabricPath core links using MAC-in-MAC header encapsulation and on

    FabricPath edge links without the MAC-in-MAC header. FabricPath VLANs can be grouped into topologies for

    traffic engineering. By default, all FabricPath VLANs belong to the base topology 0.

    CE VLANs and FabricPath VLANs cannot share a link unless the link is a FabricPath edge port.

    Declaring Ports as FabricPath Ports

    All ports that are carrying FabricPath traffic are defined as type fabricpath. With FabricPath, you dont configure

    trunking and pruning of VLANs on FabricPath ports. The required configuration to declare a port as a FabricPath

    port is very simple:

    DC1-Agg1(config)# interface ethernet 8/3

    DC1-Agg1(config-if)# description FP Link to DC1-5500-1

    DC1-Agg1(config-if)# switchport mode fabricpath

    DC1-Agg1(config-if)# no shutdown

    Topology 0

    Topology 0 is the default topology and cannot be removed; it exists by default:

    DC1-Agg1(config)# fabricpath topology ?

    Fabricpath Topology ID 1-63

    DC1-Agg1# show fabricpath isis topology ?

    Specific topology information

    summary Display summary topology information

    The only configuration that you may want to modify in order to optimize traffic distribution is the root choice for the

    multidestination trees.

    Unicast Layer 2 Multipathing

    Unicast Layer 2 multipathing is on by default, but you can select the load balancing mechanism (by default it uses

    Layer 2, Layer 3, or Layer 4 source and destination IP and VLAN) for Layer 2 traffic with the following command:

    fabricpath load-balance unicast < destination, include-vlan, layer-3, layer4,mixed, source, source-destination>

    Building a Routed Spine

    In this design recommendation, the spine also performs routing functions, and as a result the default gateway

    must be configured. When the spine is built with the Cisco Nexus 7000 Series product family, you need to

    understand the integration of F1 and M1 cards. This integration provides the combined benefits of a FabricPath

    switch for Layer 2 traffic and decapsulation and encapsulation of Layer 3 traffic into the FabricPath cloud, without

    a need for any external wiring or additional equipment.

    F1 and M1 Card Cooperation

    When an F1 card is used in a Cisco Nexus 7000 Series that provides the spine function (pure spine deployment),

    no remote MAC address learning occurs on the spine, as previously described. The F1 card doesnt do routing

    either.

    M1 cards instead provide the ability to perform routing between VLANs and toward the routed domain of the data

    center network.

  • 7/27/2019 Cisco Fabric Path-690079

    19/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 19 of 5

    If an M1 card is present in the same virtual device context (VDC) as the F1 card, the F1 card will perform learning,

    but this doesnt mean that the F1 card forwards FabricPath traffic based on MAC addresses. The F1 card forwards

    the east-to-west traffic using the remote switch-id.

    In this configuration, MAC addresses are learned on the F1 card exclusively with the purpose of being able to

    encapsulate north-to-south routed traffic into FabricPath.

    In addition to this, the learning is optimized in the sense that each component of the F1 card learns only the locally

    connected MAC addresses.

    This optimization requires the use of FabricPath on the links connecting to the edge. The reason is that the edge

    encapsulates the frames with the destination switch-id so even if learning is performed, it is only for the purpose of

    routed traffic, not for the east-to-west traffic.

    In order to fully understand, this concept you need to consider the architecture of the F1 card, which is highly

    optimized for MAC scalability.

    M1 Card Routing Traffic

    Figure 15 illustrates the traffic flow for FabricPath traffic that is routed via the M1 card. Traffic routed from one

    FabricPath VLAN to another FabricPath VLAN enters via F1 cards, exists via F1 cards, and is routed by the M1

    card.

    If traffic needs to be routed from the FabricPath cloud to a Layer 3 infrastructure, it enters from an F1 card and it

    exits via an M1 card port.

    Figure 15. Traffic forwarding with M1/F1 linecards in a Nexus 7000 chassis

    F1 Card Architecture and MAC Optimization

    East-to-west FabricPath traffic (or in other words pure Layer 2 traffic) doesnt engage the M1 card at all, nor does

    it require it. Pure Layer 2 traffic is handled by F1 cards and switched exclusively based on the switch-id

    information, as illustrated in Figure 16:

  • 7/27/2019 Cisco Fabric Path-690079

    20/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 20 of 5

    Figure 16. Forwarding with L2 traffic in a mixed M1/F1 chassis

    Because the M1 card is present and routed traffic requires being encapsulated into a FabricPath header, the F1

    card also stores MAC address mappings to destination switch-ids; hence some learning occurs, which is not used

    for Layer 2 switched traffic. In order to understand the scalability of this solution, you have to consider the

    architecture of the F1 card, which is based on the Switch-on-a-Chip concept (SoC).

    Each SoC performs switching as it if was an independent switch, and forwarding tables are not synchronized.

    Therefore, by distributing edge switches on multiple SoCs, you can take advantage of the aggregated capacity of

    all forwarding tables on the SoCs (Figure 17).

    Figure 17. High level view of ASICs arrangement in the F1 linecard

  • 7/27/2019 Cisco Fabric Path-690079

    21/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 21 of 5

    MAC Scalability Considerations

    In an M1+F1 solution and assuming that the edge switches are connected via FabricPath to the F1 card, each

    SoC learns the MAC addresses that are specific to it.

    Layer 2 traffic that doesnt leverage the default gateway doesnt require space in the Layer 2 table as it is switched

    exclusively based on the switch-id information. The MAC learning is required exclusively for routing purposes and

    Layer 2 switched traffic source MACs arent learned on the F1 card unless a switch virtual interface (SVI) is

    present on the VLAN.

    Since each SoC provides 16K MAC address capacity for the purpose of encapsulating routed traffic, the hardware

    could provide 256K MAC addresses capacity on the F1 card and 128K MAC addresses on the M1 card so the

    solution could accommodate up to 128K end devices routed by this combination of cards. A feature called

    mac-proxy (currently planned for CY12) could unleash this scalability. At the time of this writing, in certain failure

    scenarios, the traffic routed to the fabricpath cloud may use up to a maximum of 16k MAC addresses, after which

    traffic routed to any additional MAC would be flooded on one of the FTAG trees.

    Notice that this behavior has no impact for the Layer 2 east-to-west traffic because this one is switch exclusively

    based on the remote switch- ids.

    Figure 18 illustrates how the Nexus 7k builds the adjacency table for traffic routed to the Fabricpath cloud: 16k

    source MAC addresses sourced by Cisco Nexus 5500-1 are learned only by the SoC associated with port 8/3.

    The 8k source MAC addresses sourced by the Cisco Nexus 5500-2 are learned only by the SoC associated with

    port 8/5.

    Figure 18. MAC address learning with M1/F1 linecards

    The following CLI capture shows the SoC ASIC utilization with the traffic pattern described in Figure 18.

    L2 Forwarding Resources

    -----------------------

    L2 entries: Module inst total used mcast ucast lines lines_full

    8 1 16384 4 0 4 1024 0

    8 2 16384 16002 0 16002 1024 642

    8 3 16384 8001 0 8001 1024 0

    8 4 16384 1 0 1 1024 0

    8 5 16384 0 0 0 1024 0

    8 6 16384 0 0 0 1024 0

  • 7/27/2019 Cisco Fabric Path-690079

    22/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 22 of 5

    8 7 16384 0 0 0 1024 0

    8 8 16384 0 0 0 1024 0

    8 9 16384 2001 0 2001 1024 0

    So what is the scalability in terms of MAC addresses on a FabricPath design? For traffic that is purely Layer 2 -

    that is, traffic whose VLAN doesnt include an SVI - the scalability is exclusively dependent on the MAC table sizes

    of the edge devices in the topology; thus, the more edge devices, the more MAC entries you can switch. As an

    example of such VLANs, consider VLANs that are used to interconnect virtual machines (VMs) to create a virtual

    data center in a multitier environment. These VLANs often do not require any routing.

    Figure 19 illustrates a typical virtual data center (vDC): there can be several isolated networks and fenced

    networks (that is, connected via a gateway), so not all networks require a default gateway on the spine.

    Figure 19. Example of a Vitual datacenter network

    How many edge switches you can have in the same Layer 2 domain is bound to the maximum number of switch-

    ids that have been validated by testing. These numbers are published in the release notes or in the configuration

    limits in the documentation on the Cisco Nexus 5000 Series and Cisco Nexus 7000 Series.

    Note: At the time of this writing, this number varies from 64 to 128 switch-ids, depending on the software

    release and the platform.

    For traffic whose VLANs are routed, the scalability is 16k-128k MAC addresses for routed traffic, which is provided

    by the M1/F1 combination and is dependent on the traffic patterns.

    Note: As previously mentioned at the time of this writing and with this specific design, should the links

    connecting edge to spine break, forcing traffic through the asymmetric path connecting the spines, the number of

    routed MAC addresses is reduced to 16k.

    A functionality named mac-proxy, is on the roadmap for a future NX-OS SW release that will eliminating this

    caveat. Once this functionality is available (currently planned for 1HCY12), it would truly be possible to consider

    the MAC address scalability off a FabricPath domain as only dictated by the M1 MAC table space (minimum 128k)

    even in presence of multiple link failures.

  • 7/27/2019 Cisco Fabric Path-690079

    23/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 23 of 5

    Notice that even if the total MAC count is exceeded, only routed traffic will experience flooding, while Layer 2 traffic

    will be switched based on the switch-id information. For this reason, it wont be experiencing flooding.

    For more information about scalability, see the FabricPath Scalability Considerations section at the end of thisguide.

    Gateway Routing

    The gateway protocols work in FabricPath the same way they work in regular Ethernet networks. The default

    Active/Standby behavior of Hot Standby Router Protocol (HSRP) doesnt negate the value of FabricPath. Even

    without any further configuration than the standard configuration of HSRP, the Layer 2 traffic (east-to-west) would

    benefit from multipath forwarding.

    Routed traffic (south-to-north) would instead be forwarded only to the active HSRP device, as shown in Figure 20:

    Figure 20. The default HSRP configuration doesnt make use of both spines

    Active/Active Gateway Routing

    To perform traffic forwarding from multiple spines, you can use the Gateway Load Balancing Protocol (GLBP),

    which hands out a different gateway MAC (up to four different MACs) in a round-robin fashion. A better idea is to

    use the concept of vPC+ at the spine.

    The spine devices are connected by an additional FabricPath link (which would be recommended anyway to

    optimize multidestination tree forwarding) and by defining it as a vPC+ peer-link.

    The vPC+ peer-link must be built using F1 ports and not M1 ports, since it must be configured as a FabricPath link

    (Figure 21).

  • 7/27/2019 Cisco Fabric Path-690079

    24/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 24 of 5

    Figure 21. vPC+ makes active and standby HSRP devices active

    Figure 21 illustrates how traffic originating from the server connected to the edge and destined to its default-gateway can use two equal cost paths. Notice that the Active and Standby HSRP roles refer only to the control

    plane, as both aggregation devices are able to actively route traffic on the data plane.

    The configuration to achieve this behavior is as simple as follows:

    vpc domain 1

    role priority 110

    peer-keepalive destination 10.60.17.141

    fabricpath switch-id 1000

    interface port-channel10

    switchport mode fabricpath

    vpc peer-link

    Even if the configuration requires the definition of a vPC domain, there is no real vPC port in the design described

    in this topology. Notice that you need to configure a switch-id under the vPC domain configuration. This identifies

    the emulated switch.

    Because of this switch-id configuration, HSRP, VRRP, and GLBP announce their vMAC as coming from the

    emulated switch-id instead of the switch-id of each individual spine. By doing this, the edge switches can forward

    HSRP frames to either spine.

    On both spines, the HSRP MAC address is programmed in the MAC tables with the special flag (G-flag) that

    indicates that this traffic is meant to be routed.

    DC1-Agg1# show mac address-table

    Legend:

    * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC

    age - seconds since last seen, + - primary entry using vPC Peer-Link

    VLAN MAC Address Type age Secure NTFY Ports/SWID.SSID.LID

    ---------+-----------------+--------+---------+------+----+------------------

    G 101 0000.0c07.ac01 static - F F sup-eth1(R)

    Benefits of vPC+ at the Spine

    In this design guide, the use of vPC+ at the spine is strongly recommended. vPC+ gives you the ability to forward

    routed traffic to multiple routing engines as well as to optimize failover times.

  • 7/27/2019 Cisco Fabric Path-690079

    25/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 25 of 5

    As a result of this configuration, the edge switches learn the association of HSRP Virtual MAC addresses with the

    emulated switch-id instead of the individual spine switch-id:

    DC1-5500-1# show mac address-table | include 0c07

    * 101 0000.0a00.0c07 dynamic 10 F F Eth1/5

    * 101 0000.0c07.ac01 dynamic 0 F F 1000

    As Figure 22 illustrates, the use of vPC+ allows the routed traffic between any two given endpoints to benefit from

    both Layer 2 equal-cost multipathing and from the aggregated routing capacity of the spines.

    Figure 22. Traffic load balancing for both Layer 2 and Layer 3 traffic

    The existence of a dual-active path from each edge device to the emulated switch can be verified by looking at the

    FabricPath routing table, as highlighted here:

    DC1-5500-1# sh fabricpath route

    FabricPath Unicast Route Table

    a/b/c denotes ftag/switch-id/subswitch-id[x/y] denotes [admin distance/metric]

    ftag 0 is local ftag

    subswitch-id 0 is default subswitch-id

    FabricPath Unicast Route Table for Topology-Default

    1/1000/0, number of next-hops: 2

    via Eth1/1, [115/40], 0 day/s 03:39:23, isis_fabricpath-default

    via Eth1/3, [115/40], 0 day/s 03:39:23, isis_fabricpath-default

    Dual-Active Exclude (Peer-Link Failure)

    As a result of declaring the link that connects the spines as a vPC peer-link, the default behavior of vPC applies

    whereby if the peer-link goes down, the SVIs on the vPC secondary device are shut down.

    In the context of FabricPath designs, this behavior is not beneficial, because the FabricPath links are still

    available, and theres no good reason to shut down the SVIs on the secondary.

    It is thus recommended to complete the vpc domain configuration with the following command:

    vpc domain 1

    dual-active exclude vlan

  • 7/27/2019 Cisco Fabric Path-690079

    26/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 26 of 5

    Connecting FabricPath Edge or Leaf Layer to the Spine Layer

    When connecting the FabricPath edge layer to the spine layer, you can use any ports on the spine layer F1 cards

    unless the scalability of MAC addresses in the topology is a key design factor. In this case, maximizing the use ofthe SoC in the F1 card is beneficial.

    In order to do this, you just have to distribute edge switches in a way that they use different SoCs. As an example,

    you could connect edge-1 to ports 1 and 2 of the F1 card, edge-2 to ports 3 and 4, and so on (Figure 23).

    Figure 23. Best way to connect edge to spine F1 card

    Avoiding Flooding by Tuning ARP and Layer 2 Table

    The default aging time on the Layer 2 forwarding table on the Cisco Nexus 7000 Series is 1800 seconds. The

    default Address Resolution Protocol (ARP) timeout is 1500 seconds. In order to avoid flooding routed traffic, it is

    beneficial to make sure that on the spine, the ARP timeout is more aggressive than the Layer 2 forwarding table

    timeout, which is normally the default.

    Tuning the MAC address table on the edge device is not necessary because in this architecture, the edge doesnt

    perform learning based on the ARP. The edge device in a FabricPath topology learns MAC addresses only for

    active conversations.

    In the spine, the presence of the M1 card in the same VDC as the F1 card requires the F1 card to learn MAC

    addresses for the sole purpose of rewriting the routed traffic with the FabricPath information. In this specific case,

    the SoCs learn MAC addresses based on ARP, but they dont use this MAC information for Layer 2 traffic

    forwarding.

    Multicast Routing Considerations

    Multicast routing and FabricPath switching do not require particular configuration or tuning on the aggregation

    layer devices. Only PIM may require tuning if you want to reduce failover times, just like you would do in regularrouted designs.

    Multicast Forwarding in FabricPath

    As previously mentioned, FabricPath builds two multidestination trees with two different roots: one for FTag1 and

    one for FTag2. At Layer 2, multicast traffic is hashed to either tree in order to utilize both of them. The hashing to

    either multidestination tree is platform-dependent; for instance, it can include the VLAN field or the IP address

    fields.

    In order to maximize the efficiency of the traffic distribution, it is advisable to manually set the priority for the root

    for the FTag1 and FTag2 at the spine:

  • 7/27/2019 Cisco Fabric Path-690079

    27/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 27 of 5

    Agg1:

    fabricpath domain default

    root-priority 66

    Agg2:fabricpath domain default

    root-priority 65

    Traffic load-balancing can be configured with the following command:

    DC1-Agg1(config)# fabricpath load-balance multicast ?

    destination Include destination parameters

    [[

    source-destination Include source and destination parameters

    symmetric Symmetric (default)

    xor Include ex-or of source and destination parameters

    IGMP snooping is used to build the Layer 2 multicast MAC forwarding table at the edge. The information is used to

    prune traffic on a per-VLAN basis on the two multidestination trees.

    You can verify the traffic path for a given multicast group using the following command:

    DC1-Agg1# show fabricpath mroute

    (ftag/1, vlan/101, 0.0.0.0, 239.1.1.5), uptime: 00:30:24, isis

    Outgoing interface list: (count: 2)

    Interface port-channel10, uptime: 02:15:06, isis

    Interface port-channel10, uptime: 00:45:54, isis

    (ftag/1, vlan/101, 0.0.0.0, 239.1.1.6), uptime: 00:25:27, isis

    Outgoing interface list: (count: 1)

    Interface port-channel10, uptime: 00:45:54, isis

    Routed Multicast Configuration

    Its outside of the scope of this document to describe all the details of the routed multicast configuration, since it

    follows the same rules as in a non-FabricPath design:

    Enable PIM under the SVI interface.

    IGMP is automatically enabled under the SVI when PIM is enabled.

    Define the rendezvous points (RP) in the network and/or configure the spine device for auto-RP. NX-OS

    provides a specific functionality, based on RFC 4610, called Anycast-RP Using Protocol Independent

    Multicast (PIM). This functionality makes it possible to provide RP redundancy in a simpler fashion than

    when deploying Multicast Source Discovery Protocol (MSDP).

    The following is a sample configuration:

    ip pim anycast-rp 1.1.1.100 1.1.1.1

    ip pim anycast-rp 1.1.1.100 1.1.1.2

    ip pim rp-address 1.1.1.100 group-list 224.0.0.0/4

    interface loopback100

    description anycast-RP

    ip address 1.1.1.100/32

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    http://www.ietf.org/rfc/rfc4610.txt
  • 7/27/2019 Cisco Fabric Path-690079

    28/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 28 of 5

    From an operational perspective, it may be advisable to align the PIM designated router (DR) priority with the

    HSRP primary.

    Note: The FTag selection for routed multicast traffic may change after routing. Post-routed traffic may beforwarded on a different FTag tree than the prerouted traffic.

    PIM times are by default very conservative, and they are the cause of the slower convergence times that are

    measured for multicast traffic. You can bring them down significantly by either tuning the PIM timers or by using

    Bidirectional Forwarding Detection (BFD) for PIM.

    Here is an example of the configuration:

    bfd interval 50 min_rx 100 multiplier 3

    interface Vlan101

    [...]

    ip pim sparse-mode

    ip pim bfd-instance

    ip pim dr-priority 10

    ip pim hello-interval 1000

    Note: PIM interval tuning should be considered with care because when deployed on too many interfaces, it

    may increase the CPU utilization. BFD scales better. For information on scalability, please refer to the release

    notes and/or the configuration limits.

    Routed Multicast with vPC+

    When using vPC+ in conjunction with the FTag priority settings that were previously described, the hashing of

    routed multicast traffic is optimized, as illustrated in Figure 24.

    Figure 24. Multicast routing with FabricPath

    This means there is a sort of affinity behavior, based on which each vPC+ peer device will always use the

    multicast destination tree rooted on itself to forward multicast traffic.

    Summary Recommendations

    This section summarizes the recommendation for building a Layer 3 spine in a FabricPath topology. Figure 25

    illustrates these recommendations.

    Configure VLANs in FabricPath mode.

  • 7/27/2019 Cisco Fabric Path-690079

    29/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 29 of 5

    Consider using manually configured switch-ids. This can help with managing and operating the topology

    since you can define the numbering scheme.

    Configure SVIs and HSRP as usual.

    Configure vPC+ by defining a vPC peer-link and an emulated switch-id in the vPC domain. This is to allow

    integration of legacy (non-FabricPath-enabled) edge layer devices and to provide Active/Active default-

    gateway data-plane functionality.

    Configure Layer 3 peering between routers over a FabricPath VLAN (for instance, on the same link that is

    used to interconnect the spine devices, such as the vPC+ peer-link). This is required to reroute traffic

    destined to the northbound Layer 3 domain if one of the aggregation devices loses physical connectivity to

    the upstream devices.

    Use FabricPath-enabled links for vPC peer-link purposes.

    Configure dual-active exclude vlan for the list of SVIs (unless using vPC attached devices).

    Distribute edge switches onto different SoCs on the F1 card for maximum MAC address scalability. Even if this is the default configuration, at the spine, you may want to verify that the ARP aging timeout is

    faster than the Layer 2 forwarding table timeout.

    Figure 25. Summary recommendations for FabricPath designs

    Design Considerations for the Edge and Access Layer

    The edge layer in FabricPath provides Classic Ethernet connectivity to servers and interfaces with FabricPath core

    ports to the spine layer.

    The edge layer performs unicast Layer 2 multipathing load balancing on equal-cost-path Layer 2 routes.

    Flooded and unknown unicast traffic is sent on the multidestination tree associated with FTag1. Multicast traffic is

    load balanced on the two multidestination trees (identified as usual with FTag1 and FTag2).

    FabricPath VLANs

    As with the spine layer, the access port in a FabricPath topology can be configured by assigning a FabricPath

    VLAN to an access port.

    You should start the configuration by making a VLAN a FabricPath type of VLAN:

    DC1-5500-1# show vlan id 101

  • 7/27/2019 Cisco Fabric Path-690079

    30/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 30 of 5

    VLAN Name Status Ports

    ---- -------------------------------- --------- -------------------------------

    101 FP_VLAN_101 active Eth1/5

    VLAN Type Vlan-mode---- ----- ----------

    101 enet FABRICPATH

    The ports connecting the edge device to the spine or even to another edge device should be configured as

    FabricPath core ports:

    (config-if)# switchport mode fabricpath

    The ports connecting to servers are configured as switchport mode access or trunk access. They can forward the

    traffic with the regular Ethernet encapsulation.

    To distribute unicast traffic via equal-cost multipath (ECMP), use the following command:

    DC1-5500-2(config)# fabricpath load-balance unicast < destination, include-vlan,

    layer-3, layer4, mixed, source, source-destination>

    Note: By default, the unicast hashing is configured to include the source and destination IP addresses.

    MAC Learning at the Access Layer

    The edge layer by default performs conversational learning. Conversational learning spares MAC address table

    consumption at the edge because remote MAC addresses are not learned in the Layer 2 forwarding table unless

    theres an active conversation between a local node and a remote node.

    If you configure an SVI on a FabricPath VLAN, conversational learning is disabled on this VLAN. It is therefore

    normally recommended to not configure management SVIs on FabricPath VLANs.

    Learning the HSRP MAC Address

    The HSRP and GLBP MAC addresses - and in general the gateway vMAC addresses - are of particular interest

    because theres never an active conversation between an end host and a vMAC. The reason is that when the

    server sends traffic to the gateway, it does use the vMAC as the destination MAC address, but when the router

    sends traffic to the end host, it never uses the vMAC as source MAC address; instead, it uses the burned-in

    address (BIA).

    If the edge switch was not learning the gateway vMAC address, all traffic destined to be routed would be

    continuously flooded. The mechanism that solves this problem consists in considering HSRP, GLBP, or VRRP

    hellos as part of the conversation with an end host. When a host sends traffic destined to the gateway vMAC

    address, the edge switch stores it temporarily in the Layer 2 forwarding table. As soon as an HSRP hello is

    received, it programs the switch-id associated with it.

    If the spine is configured for vPC+, the source switch-id is the emulated switch-id. As a result, the MAC address

    table of the edge switch will have the HSRP MAC associated with the emulated switch-id.

    DC1-5500-2# show mac address-table vlan 101

    Legend:

    * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC

    age - seconds since last seen,+ - primary entry using vPC Peer-Link

    VLAN MAC Address Type age Secure NTFY Ports

    ---------+-----------------+--------+---------+------+----+----------

    * 101 0000.0c07.ac01 dynamic 0 F F 1000

  • 7/27/2019 Cisco Fabric Path-690079

    31/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 31 of 5

    Direct Connectivity between Edge Switches

    One interesting point to observe is that edge switches can be connected directly to each other. This can be used

    to provide a direct path between hosts. Consider Figure 26:

    Figure 26. Direct connectivity between edge switches allows direct communication between servers

    When DC1-5500-2 to DC1-5500-3 is connected, the two hosts can talk directly over this link without having to go

    via the spine switches. This is unique to FabricPath. Spanning Tree Protocol would have blocked this link.

    vPC+ at the Edge

    The edge switches can be configured to perform vPC-like functions, which in the particular case of a FabricPath

    infrastructure are referred to as vPC+ (as already discussed for providing Active/Active default-gateway

    functionalities on the spine/aggregation devices).

    Functions that are enabled by vPC+ at the edge include:

    The ability to attach servers to edge switches with port-channel teaming

    The ability to attach additional Classic Ethernet switches in vPC mode

    The ability to attach Cisco Fabric Extenders in FEX Active/Active mode.

    The key requirement for a vPC+ configuration to be operational in FabricPath is to define the emulated switch-id in

    the vPC domain configuration. The other requirement is that the vPC peer-link must be a FabricPath link. All

    VLANs on vPC+ links must be FabricPath VLANs.

    When the peer-link goes down vPC+ operates similarly to vPC

    When all the links of the peer-link fail, the primary switch will take no action, and the secondary switch willbring down all its vPC links.

    In addition, vPC+ also intervenes to prevent attracting traffic to the vPC secondary switch. This function is

    provided by IS-IS by ensuring that the secondary switch stops advertising reach ability information to the

    emulated switch. This is essential to prevent the secondary switch from attracting traffic destined for the

    emulated switch from the FabricPath cloud.

  • 7/27/2019 Cisco Fabric Path-690079

    32/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 32 of 5

    Figure 27 illustrates a design with vPC+:

    Figure 27. Using vPC+ on the edge switches

    In such a topology, the MAC addresses associated with a pair of edge devices running vPC+ are advertised to the

    other switches that are part of the same FabricPath domain as belonging to the emulated switch-id, instead of the

    individual switch-ids of the edge Cisco Nexus 5500 Switches.

    Overall, with vPC+ most of the communications between devices that connect to the vPC+ peers is kept local and

    doesnt involve the spines. This is true for both vPC connected devices and for orphan ports as well. Orphan portsin vPC+ can communicate over the peer-link as if this link were a regular FabricPath link (Figure 28):

    Figure 28. Communication between devices connected to a vPC+ edge

  • 7/27/2019 Cisco Fabric Path-690079

    33/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 33 of 5

    In addition, even if the vPC+ peer-link were to fail, Host1 and Host4 would not lose connectivity because they

    would still be able to communicate via the spines. In Figure 28, Host1 and Host4 send traffic to the switch-id of the

    respective edge switches and not to the emulated switch-id. As for the north-to-south traffic flows destined to the

    hosts supported by vPC links, they are sent to the vPC primary only as the vPC secondary device stops

    advertising edge MAC address information associated to the emulated switch-id (Figure 29).

    Figure 29. vPC+ behavior upon loss of the peer-link

    Integration with FEX

    You can extend FabricPath topologies by adding Cisco Fabric Extenders. Fabric extender ports are edge ports,

    and if you are using vPC+, they allow creating vPCs between servers and FEX. Dual-layer vPC is also

    implemented.

    Summary

    In summary, at the edge layer there is no major tuning necessary. The configuration is very simple:

    You should configure VLANs as FabricPath VLANs.

    Consider using manually configured switch-ids. This can help with managing and operating the topology

    since you can define the numbering scheme.

    To avoid disabling conversational learning, make sure not to have an SVI (like the management SVI) on a

    FabricPath VLAN.

    Consider the use of vPC+ if using port-channel teaming or FEX Active/Active or adapter-FEX/VM-FEX.

    FabricPath Scalability Considerations

    In terms of FabricPath scalability, there are three main elements you should consider in a given FabricPath

    domain:

    Number of switches

    Number of VLANs

    Number of MAC addresses

  • 7/27/2019 Cisco Fabric Path-690079

    34/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 34 of 5

    The maximum number of switches and VLANs supported (that is, tested by QA) in the same FabricPath domain is

    continuously increasing at every Cisco NX-OS Software release. At the time of writing of this document, these are

    the expected supported values:

    Cisco Nexus 7000 Series (NX-OS Release 6.0): 128 switch-ids and between 2000 and 4000 VLANs

    Cisco Nexus 5500 Switches (NX-OS Release 5.1(3)N1(1)): 128 switch-ids and between 2000 and 4000

    VLANs

    Note: For updated information on the maximum number of switch-ids supported within the same FabricPath

    domain, please refer to the release notes and the configuration limits documentation for each specific software

    release.

    One of the benefits of FabricPath is the scalability both in terms of MAC addresses and in terms of

    throughput/oversubscription ratios.

    In terms of MAC address scalability, we should differentiate between edge and spine devices.

    The edge switches learn only MAC addresses for which there are active conversations established (conversational

    learning). The focus of this document is on using the Cisco Nexus 5500 Switches at the edge of the FabricPath

    network. The current maximum value of MAC addresses supported on these devices is 24k.

    For the spine devices, it is important to distinguish between east-to-west (switched) and north-to-south (routed)

    traffic flows:

    East-west traffic: These flows are switched by the spine devices based on the outer MAC header

    information (FabricPath switch-id values) (see Figure 30). For the spine devices to perform this switching,

    there is technically no need for them to learn the MAC addresses of the endpoints connected to the

    FabricPath edge switches.

    Figure 30. FabricPath spines switch traffic based on the Destination Switch-id (DSID)

    North-south traffic: Traffic coming from the Layer 3 network domain and directed to an endpoint connected

    to a FabricPath edge switch needs to be first handled by the M1 card (performing routing functionalities)

    and eventually sent out to the FabricPath core through an F1 interface.

  • 7/27/2019 Cisco Fabric Path-690079

    35/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 35 of 5

    Figure 31. Traffic routing by M1 card and subsequent FabricPath encapsulation by F1 card

    This essentially means that the MAC addresses scalability is mainly dictated by the CAM table available on the M1

    card, which is capable of containing 128k addresses. The M1 card has all the information needed (MAC address,

    switch-id of the edge device) to internally forward the traffic to the F1 interface that is properly connected to the

    destination FabricPath edge switch.

    However, as previously discussed in the section MAC Scalability Considerations, the endpoint MAC addresses

    are also learned on the F1 card instead. This is because in the current implementation, the F1 card needs to

    associate to each remote MAC address a specific value (named local ID [LID]) and insert it into the FabricPath

    header before sending the frame toward the edge switch (Figure 32).

    Figure 32. F1 learning MAC addresses for routed traffic purposes

  • 7/27/2019 Cisco Fabric Path-690079

    36/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 36 of 5

    The end result is that each SoC is currently learning all the remote MAC addresses for endpoints locally attached

    to each FabricPath edge switch. This happens in an independent fashion, whether or not traffic belongs to the

    same VLAN, which essentially brings the maximum MAC scalability values to 256k per F1 card (since it supports

    16 SoCs, each capable of holding up to 16k MAC addresses). By properly assigning edge switches to spine ports,

    it is theoretically possible to use the aggregated capacity of the spine F1 cards switch-on-chips (SoC) component

    for up to 128k MAC addresses for routed traffic.

    However, at the time of this writing, the maximum number of MAC addresses that can be stored for routing

    purposes without incurring into flooding is 16k. The reason is described by the following examples. Lets assume

    that one of the uplinks connecting a FabricPath edge switches to the spine fails, as shown in Figure 33:

    Figure 33. Failure scenarios for routed traffic

    Traffic that originated from the upstream Layer 3 core devices can still be sent to the left aggregation switch, but it

    needs to use the transit connection (vPC+ peer-link) between the spines to be directed toward the FabricPath

    edge switch. As a consequence, the MAC addresses of the endpoints connected to that specific FabricPath edge

    switch will need to be installed on the MAC tables of the SoCs associated to these peer-link interfaces. This would

    basically limit to 16k the total amount of MAC addresses that can be learned on the FabricPath edge switch, in

    order to avoid flooding the routed traffic whose MACs have not been learned.

    Obviously, the situation would become worse if multiple uplinks belonging to separate FabricPath switches fail at

    the same time, leading to an extremely unlikely case where the maximum MAC scalability supported across the

    entire FabricPath domain is reduced to 16k MAC addresses (Figure 34).

  • 7/27/2019 Cisco Fabric Path-690079

    37/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 37 of 5

    Figure 34. Impact of multiple links failure for routed traffic

    If this unlikely scenario is a concern, it is possible to deploy port-channels (instead than single links) to

    interconnect each FabricPath edge devices to the spine switches. In that way, a single link failure event would not

    force the traffic on the peer-link.

    It is also worth noting that a specific functionality, named mac-proxy, is on the roadmap for a future NX-OS SW

    release that will help eliminating the issue described above, by removing the need for the F1 SoCs to learn

    endpoint MAC address information. Once this functionality is available (currently planned for 1HCY12), it would

    truly be possible to consider the MAC address scalability off a FabricPath domain as only dictated by the M1 MAC

    table space (minimum 128k).

    For Layer 2 traffic (that is, traffic that is not directed to the default gateway), the MAC address scalability is

    dependent only on the MAC scalability of the edge devices. This is even more relevant for VLANs that do not

    require routing, such as the isolated networks constituted by the virtual server building blocks of typical virtual

    data centers (vDCs), like the ones depicted in Figure 35:

  • 7/27/2019 Cisco Fabric Path-690079

    38/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 38 of 5

    Figure 35. vDCs use many isolated VLANs

    In such cases, the MAC address scalability for isolated VLANs is entirely decoupled from the F1 learning

    component.

    In all cases, east-to-west Layer 2 traffic doesnt use the MAC address table of the spine devices.

    Finally, the ability to do unicast multipathing on up to 16 different equal-cost paths makes it possible to place up to

    16 spines in the core, thus lowering the oversubscription and providing an aggregated bandwidth that equals the

    sum of the bandwidth provided at the spine layer by each spine.

    FabricPath Convergence Times

    Cisco FabricPath improves significantly on the convergence times for any given failure. For most unicast failures,

    the traffic loss is within a few hundred milliseconds. For routed traffic, the worst convergence time is the time that it

    takes for routers to do an SPF calculation. Considering the various throttling mechanisms, this amounts to ~5

    seconds, which can be further lowered by changing the default OSPF timers on the adjacent routing devices. The

    configuration required to achieve this is very simple:

    router ospf 10

    timers throttle spf 10 100 5000

    timers throttle lsa all 10 100 5000

    timers lsa arrival 80

    For Layer 2, multicast convergence times are also within a few hundred milliseconds, while for routed multicast,

    PIM must be tuned via BFD and/or more aggressive timers than the defaults. Routed multicast with proper tuningcan converge within a couple of seconds.

    Notice that these slower convergence times are not due to FabricPath but to default timers in routing protocols.

    FabricPath has failure convergence times of a few hundred milliseconds.

    For better failover times, consider the following:

    Use vPC+ at the spine in order for HSRP to be advertised with the emulated switch-id.

    Consider tuning the default OSPF SPF timers to avoid throttling SPF recalculations too much.

    Consider tuning the default PIM timers and or using BFD.

  • 7/27/2019 Cisco Fabric Path-690079

    39/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 39 of 5

    Sample Configurations

    This section illustrates how to configure the Cisco Nexus 7000 Series Switches and Cisco Nexus 5500 Switches

    for a spine-edge design with the spine also providing the Layer 3 gateway function. The configuration samples

    refer to the network topology shown Figure 36.

    Figure 36. Reference Topology for the configurations provided in this document

    Note that in regard to topology shown in Figure 36 and following configuration samples, the F1 line card is inserted

    in slot 8, and the M1 line card is inserted in slot 10.

    Cisco Nexus 7000 Series Spine 1 (DC1-Agg1)

    install feature-set fabricpath

    hostname DC1-Agg1

    vdc DC1-Agg1 id 1

    allow feature-set fabricpath

    []

    feature-set fabricpath

    []feature ospf

    feature pim

    feature interface-vlan

    feature hsrp

    feature lacp

    feature glbp

    feature vpc

    feature pong

    feature bfd

  • 7/27/2019 Cisco Fabric Path-690079

    40/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 40 of 5

    bfd interval 50 min_rx 100 multiplier 3

    vlan 101mode fabricpath

    name FP_VLAN_101

    vlan 102

    mode fabricpath

    name FP_VLAN_102

    vlan 103

    mode fabricpath

    name FP_VLAN_103

    vlan 333

    mode fabricpath

    name Aggr_IGP_Peering

    vpc domain 1

    role priority 110

    peer-keepalive destination 10.60.17.141

    delay restore 3600

    dual-active exclude interface-vlan 101-104

    fabricpath switch-id 1000

    interface Vlan101

    no shutdown

    ip address 10.20.0.2/16

    ip ospf passive-interface

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    ip pim bfd-instance

    ip pim dr-priority 10

    ip pim hello-interval 1000

    hsrp 1

    preempt delay reload 300

    priority 110

    ip 10.20.0.1

    interface Vlan102

    no shutdown

    ip address 10.30.0.2/16

    ip ospf passive-interface

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    ip pim bfd-instance

    ip pim hello-interval 1000

    hsrp 1

    preempt delay reload 300

  • 7/27/2019 Cisco Fabric Path-690079

    41/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 41 of 5

    priority 110

    ip 10.30.0.1

    interface Vlan103no shutdown

    ip address 10.40.0.2/16

    ip ospf passive-interface

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    hsrp 1

    preempt delay reload 300

    priority 110

    ip 10.40.0.1

    interface Vlan333

    no shutdown

    description Aggr_IGP_Peering

    no ip redirects

    ip address 11.1.10.1/24

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    interface port-channel1

    description FP Link to DC1-5500-1

    switchport

    switchport mode fabricpath

    interface port-channel10

    description vPC+ Peer-Link

    switchport

    switchport mode fabricpath

    vpc peer-link

    interface Ethernet8/1

    description vPC+ Peer-Link Member 1

    switchport mode fabricpath

    channel-group 10 mode active

    no shutdown

    interface Ethernet8/2

    description vPC+ Peer-Link Member 2

    switchport mode fabricpath

    channel-group 10 mode active

    no shutdown

    interface Ethernet8/3

    description Port-channel to DC1-5500-1 Member 1

  • 7/27/2019 Cisco Fabric Path-690079

    42/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 42 of 5

    switchport mode fabricpath

    channel-group 1 mode active

    no shutdown

    interface Ethernet8/4

    description Port-channel to DC1-5500-1 Member 2

    switchport mode fabricpath

    channel-group 1 mode active

    no shutdown

    interface Ethernet8/5

    description FP Link to DC1-5500-2

    switchport mode fabricpath

    no shutdown

    interface Ethernet8/7

    description FP Link to DC1-5500-3

    switchport mode fabricpath

    no shutdown

    interface Ethernet10/5

    description L3 Link to core

    ip address 12.1.5.1/24

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    no shutdown

    interface mgmt0

    ip address 10.60.17.140/24

    interface loopback0

    description local-loopback

    ip address 1.1.1.1/32

    ip router ospf 10 area 0.0.0.0

    interface loopback100

    description anycast-RP

    ip address 1.1.1.100/32

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    router ospf 10

    router-id 1.1.1.1

    timers throttle spf 10 100 5000

    timers throttle lsa all 10 100 5000

    timers lsa arrival 80

  • 7/27/2019 Cisco Fabric Path-690079

    43/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 43 of 5

    fabricpath domain default

    root-priority 66

    topology 1

    ip pim rp-address 3.3.3.3 group-list 224.0.0.0/4

    ip pim ssm range 232.0.0.0/8

    fabricpath switch-id 121

    Cisco Nexus 7000 Series Spine 2 (DC1-Agg2)

    install feature-set fabricpath

    hostname DC1-Agg2

    vdc DC1-Agg2 id 1

    allow feature-set fabricpath

    []

    feature-set fabricpath

    feature vrrp

    cfs eth distribute

    feature ospf

    feature pim

    feature msdp

    feature interface-vlan

    feature hsrp

    feature lacp

    feature glbp

    feature vpc

    feature pong

    feature bfd

    bfd interval 50 min_rx 100 multiplier 3

    vrf context management

    ip route 0.0.0.0/0 10.60.17.254

    vlan 101

    mode fabricpath

    name FP_VLAN_101

    vlan 102mode fabricpath

    name FP_VLAN_102

    vlan 103

    mode fabricpath

    name FP_VLAN_103

    vlan 333

    mode fabricpath

    name Aggr_IGP_Peering

  • 7/27/2019 Cisco Fabric Path-690079

    44/53

    2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 44 of 5

    vpc domain 1

    peer-keepalive destination 10.60.17.140

    delay restore 3600

    dual-active exclude interface-vlan 101-104fabricpath switch-id 1000

    interface Vlan101

    no shutdown

    no ip redirects

    ip address 10.20.0.3/16

    ip ospf passive-interface

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    ip pim bfd-instance

    ip pim hello-interval 1000

    hsrp 1

    ip 10.20.0.1

    interface Vlan102

    no shutdown

    no ip redirects

    ip address 10.30.0.3/16

    ip ospf passive-interface

    ip router ospf 10 area 0.0.0.0

    ip pim sparse-mode

    ip pim bfd-instance

    ip pim hello-interval 1000

    hsrp 1

    ip 10.30.0.1

    interface Vlan103

    no shutdown

    no ip redirec