Cisco cBR Router Thermal Monitoring and Troubleshooting Overview of the Cisco cBR Router Thermal Monitoring 2 Enabling Thermal Shutdown 2 Recovering a Card After a Thermal Shutdown 3 Viewing the System Component Temperatures 3 Viewing Temperature Sensor Alarm Status 3 Setting Up SNMP Traps for Temperature Alarms 4 SUP_dSUM Alarm 7 Critical Thermal Sensor Identifiers and Temperature Limit Set-Points for Specific Line Cards 7

Upload: others

Post on 13-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

Cisco cBR Router Thermal Monitoring and TroubleshootingOverview of the Cisco cBR Router Thermal Monitoring 2

Enabling Thermal Shutdown 2

Recovering a Card After a Thermal Shutdown 3

Viewing the System Component Temperatures 3

Viewing Temperature Sensor Alarm Status 3

Setting Up SNMP Traps for Temperature Alarms 4

SUP_dSUM Alarm 7

Critical Thermal Sensor Identifiers and Temperature Limit Set-Points for Specific Line Cards 7

Page 2: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

Revised: June 7, 2018

Overview of the Cisco cBR Router Thermal MonitoringThe Cisco cBR routers are equipped with a comprehensive thermal monitoring system. You can enable the thermal protection shutdownof the system for critical thermal sensors. The routers have preconfigured thermal shutdown levels and general alarm levels for allthe sensors. The values indicated in this document are specific to the product IDs referenced and apply to Cisco IOS-XE 3.18.0S andlater.

The main cooling system of the Cisco cBR comprises of five fan modules at the rear of the chassis with two fans placed within eachmodule. Additionally, the power modules have two internal fans each for self-cooling.

The Cisco cBR does not power up if all the five fan modules are not installed. The fan modules do not have to be 100% functionalbut they must all be present. The fan modules (functional or not) are required to be installed in the chassis at startup to seal the chassisfan bay slot and prevent recirculation to the functional fans.

When an individual fan fails or the complete fan module is removed, the system continues to run and post alarms. The system doesnot power down because of missing or failed fans. Alarms are posted for failed or removed fan modules and any thermal event thatoccurs at the line card level. The system relies on the line card level thermal monitoring of the critical sensors and any enabled systemthermal protection to shut down a line card.

Overview of the Cisco cBR AC and DC Power Supplies Thermal Sensors

The Cisco cBRACPower Supply (cBR-AC-PS) and Cisco cBRDCPower Supply (cBR-DC-PS) (CBR8 power supplies) are equippedwith over temperature protection shutdown. This safety feature CANNOT be turned off and is configured by the manufacturer of thepower supply. The power supplies have numerous sensors placed throughout to prevent thermal run away. If a power supply sensorreaches its over temperature limit the power supply will shut itself down.

The released power supplies have only the inlet and outlet temperature sensors that are read by IOS. The power supply inlet sensorhas a preconfigured over temperature protection shutdown limit set at 65C. With sensor tolerances an over temperature shutdowncan occur as low as 60C TRUE facility inlet temperature. This setting is above the recommended operational range for the CBR8product.

If there are not enough power supply modules functioning it can cause a system to shutdown the linecards first, then secondly theentire system.

Enabling Thermal ShutdownYou can configure the Cisco cBR system to protect the major power consuming chips in the chassis that reside on the front line cards.When you enable the thermal shutdown configuration, the chassis shuts down the line cards when the major heat generating chipsreach their design limits listed in the tables in the section Critical Thermal Sensor Identifiers and Temperature Limit Set-Points forSpecific Line Cards, on page 7. Only the line card with a thermal event is shutdown.

To enable the thermal shutdown feature, complete the following procedure:

router#configure terminalrouter(config)#facility-alarm critical exceed-action shutdown

The primary supervisor is an exception to the thermal shutdown configuration. When the thermal shutdown feature is enabled andthe primary supervisor has a thermal event that exceeds the shutdown limit, all the front line cards in the chassis are shut down but

2

Page 3: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

the primary supervisor continues to run and provide telemetry until the failure or event is cleared or the system completely shutsdown due to the thermal event.

The thermal shutdown configuration affects only the front line cards and does not affect the rear physical interface card (PIC), powersupplies, or fan modules.

Recovering a Card After a Thermal ShutdownYou must clear the thermal events on the line card and the primary supervisor before the line card comes back online.

After a thermal shutdown event, you must review the alarms, system and facility temperatures, and failure logs to determine the rootcause of the thermal event and correct it.

Once a line card is placed into the thermal shutdown state, there are three ways to recover the line card:

• Issue the hw-module slot x reload command—You can issue this command and try to bring the line card back online. Thiscommand must be issued twice. The first issue of the command resets the line card and the line card will default to be offline.The second issue of the command allows the card to boot up if the thermal event alarm is cleared.

• Online insertion and removal (OIR) of the card or a complete card replacement—This procedure allows the line card slot to bootup. Youmust perform this procedure twice or along with the hw-module slot x reload command. Before OIR or card replacement,you must issue the hw-module slot x reload command. After the card is reset, you can OIR or replace the card. On reinsertingthe card it boots up normally if the thermal event is cleared.

• Reboot or power cycle of the entire chassis—This procedure also clears the thermal shutdown alarm. If the thermal conditionspersist upon rebooting, the line cards shift into the shutdown state.

Viewing the System Component TemperaturesTo view the system component temperatures, use the show env | inc Temp command.

The following example shows the output for the show env | inc Temp command.

router#show env | inc Temp5/1 Temp: RTMAC Normal 40 Celsius5/1 Temp: INLET Normal 31 Celsius5/1 Temp: OUTLET Normal 31 Celsius5/1 Temp: MAX6697 Normal 54 Celsius5/1 Temp: TCXO Normal 37 Celsius5/1 Temp: SUP_OUT Normal 54 Celsius5/1 Temp: 3882_1 P Normal 46 Celsius5/1 Temp: 3882_2 P Normal 40 Celsius5/1 Temp: 3882_3 P Normal 46 Celsius5/1 Temp: INLET PD Normal 28 Celsius

The output displays the slot location, sensor name, status, and temperature.

Viewing Temperature Sensor Alarm StatusTo view the posted temperature sensor alarms, use the show facility-alarm status command to show all the alarms in the system.This command also shows if the fan modules are installed and functioning properly and other important alarm states related to athermal event.

3

Page 4: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

The following example shows the output for the show facility-alarm status command.

router#show facility-alarm statusSystem Totals Critical: 11 Major: 1 Minor: 0

Source Time Severity Description [Index]------ ------ -------- -------------------Temp: Outlet P0/4 Apr 18 2016 13:05:12 INFO Temp Above Normal [4]Temp: Outlet P1/4 Apr 18 2016 13:05:12 INFO Temp Above Normal [4]Temp: Outlet P2/4 Apr 18 2016 13:05:12 INFO Temp Above Normal [4]Power Supply Bay 1 Apr 18 2016 13:05:12 INFO Power Supply/FAN Module Missing [2]Power Supply Bay 3 Apr 18 2016 13:05:12 INFO Power Supply/FAN Module Missing [2]Power Supply Bay 4 Apr 18 2016 13:05:12 INFO Power Supply/FAN Module Missing [2]Power Supply Bay 5 Apr 18 2016 13:05:12 INFO Power Supply/FAN Module Missing [2]Fan Slot 0 Apr 18 2016 13:05:12 CRITICAL Fan Tray Module Missing [0]Fan Slot 0 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1]Fan Slot 1 Apr 18 2016 13:05:12 CRITICAL Fan Tray Module Missing [0]Fan Slot 1 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1]Fan Slot 2 Apr 18 2016 13:05:12 CRITICAL Fan Tray Module Missing [0]Fan Slot 2 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1]Fan Slot 3 Apr 18 2016 13:05:12 CRITICAL Fan Tray Module Missing [0]Fan Slot 3 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1]Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL Fan Tray Module Missing [0]Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1]Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port Administrative State Down [1]Cable3/0-MAC4 Apr 18 2016 13:07:05 INFO Physical Port Administrative State Down [1]sup 0 Apr 18 2016 13:05:13 MAJOR Unknown state [0]TenGigabitEthernet5/1/3 Apr 18 2016 19:13:17 CRITICAL Physical Port Link Down [35]SFP+ container 5/1/4 Apr 18 2016 13:05:23 INFO Transceiver Missing [0]SFP+ container 5/1/5 Apr 18 2016 13:05:23 INFO Transceiver Missing [0]SFP+ container 5/1/6 Apr 18 2016 13:05:23 INFO Transceiver Missing [0]SFP+ container 5/1/7 Apr 18 2016 13:05:23 INFO Transceiver Missing [0]

To view only the thermal alarms, use the show facility-alarm status | inc Temp command.

The following example shows the output for the show facility-alarm status | inc Temp command.

router#show facility-alarm status | inc TempTemp: Outlet P0/4 Apr 18 2016 13:05:12 INFO Temp Above Normal [4]Temp: Outlet P1/4 Apr 18 2016 13:05:12 INFO Temp Above Normal [4]Temp: Outlet P2/4 Apr 18 2016 13:04:12 INFO Temp Above Normal [4]Temp: U18 P10/1 Apr 18 2016 13:03:12 INFO Temp Above Normal [4]Temp: U17 P11/1 Apr 18 2016 13:01:12 INFO Temp Above Normal [4]

Setting Up SNMP Traps for Temperature AlarmsYou can send alarms to a trap server and capture using the snmp-server enable traps alarms informational command. This commandenables traps for all the alarms and not only the thermal alarms. There is no command to enable traps only for the thermal alarm. Youcannot configure the system to set temperature alarm values as the thresholds are preprogramed on the line cards.

Below is an example of a thermal alarm trap. This example shows a critical alarm for slot 5 BB_DIE on the CBR-SUP-160G card.Received SNMPv1 Trap:Community: publicEnterprise: ciscoEntityAlarmMIBNotificationsPrefixAgent-addr: 10.0.10.10Enterprise Specific trap.Enterprise Specific trap: 1Time Ticks: 362693ceAlarmHistEntPhysicalIndex.74 = 60142

4

Page 5: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

ceAlarmHistAlarmType.74 = 2ceAlarmHistSeverity.74 = critical(1)ceAlarmHistTimeStamp.74 = 362692ceAlarmDescrText.9.2 = Temp Above Normal

In the example above, you can find “ceAlarmHistEntPhysicalIndex.74 = 60142” in the trap. Using this index you can get the detaildescriptor in the SNMP table “entPhysicalDescr”.

For example, entPhysicalDescr.60142 = Temp: BB_DIE.

Each thermal alarm trap contains its PhysicalIndex. For example, for BB_DIE: ceAlarmHistEntPhysicalIndex.74 = 60142, its indexstarts with 6xxxx. For the front linecards, cylons, and SUP, cylons and SUP, the PhysicalIndex start from (slot+1)*10,000.

In this example, the equation is (slot5+1)*10,000 = 6000, which means the sensor that has sent the alarm is in slot 5.

Once you get the sensor's PhysicalIndex that starts from (slot+1)*10,000, use the above formula to get the slot number, and searchfor the PhysicalIndex in the entPhysicalDescr table to get its descriptor.

Each line card and type has a different entPhysicalDescr table. Always reference the entPhysicalDescr table for your specific linecard that an alarm is originating from.

The following are some examples of entPhysicalDescr tables.

• Example entPhysicalDescr for temperature sensors for power supplies installed in bay P0 and P5. P1-P4 bays are empty.entPhysicalDescr.1000 = Power Supply BayentPhysicalDescr.1001 = Cisco cBR CCAP AC Power SupplyentPhysicalDescr.1002 = PEM IoutentPhysicalDescr.1003 = PEM VoutentPhysicalDescr.1004 = PEM VinentPhysicalDescr.1005 = Temp: INLETentPhysicalDescr.1006 = Temp: OUTLETentPhysicalDescr.1020 = Power Supply BayentPhysicalDescr.1040 = Power Supply BayentPhysicalDescr.1060 = Power Supply BayentPhysicalDescr.1080 = Power Supply BayentPhysicalDescr.1100 = Power Supply BayentPhysicalDescr.1101 = Cisco cBR CCAP AC Power SupplyentPhysicalDescr.1102 = PEM IoutentPhysicalDescr.1103 = PEM VoutentPhysicalDescr.1104 = PEM VinentPhysicalDescr.1105 = Temp: INLETentPhysicalDescr.1106 = Temp: OUTLET

• Example entPhysicalDescr for temperature sensors for fan modules installed in P10-P14 bays.entPhysicalDescr.2000 = Fan SlotentPhysicalDescr.2001 = Cisco cBR Fan AssemblyentPhysicalDescr.2002 = Temp: U17entPhysicalDescr.2003 = Temp: U18entPhysicalDescr.2004 = Temp: FCentPhysicalDescr.2005 = MPL115AentPhysicalDescr.2012 = FanentPhysicalDescr.2013 = FanentPhysicalDescr.2020 = Fan SlotentPhysicalDescr.2021 = Cisco cBR Fan AssemblyentPhysicalDescr.2022 = Temp: U17entPhysicalDescr.2023 = Temp: U18entPhysicalDescr.2024 = Temp: FCentPhysicalDescr.2025 = MPL115AentPhysicalDescr.2032 = FanentPhysicalDescr.2033 = FanentPhysicalDescr.2040 = Fan Slot

5

Page 6: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

entPhysicalDescr.2041 = Cisco cBR Fan AssemblyentPhysicalDescr.2042 = Temp: U17entPhysicalDescr.2043 = Temp: U18entPhysicalDescr.2044 = Temp: FCentPhysicalDescr.2045 = MPL115AentPhysicalDescr.2052 = FanentPhysicalDescr.2053 = FanentPhysicalDescr.2060 = Fan SlotentPhysicalDescr.2061 = Cisco cBR Fan AssemblyentPhysicalDescr.2062 = Temp: U17entPhysicalDescr.2063 = Temp: U18entPhysicalDescr.2064 = Temp: FCentPhysicalDescr.2065 = MPL115AentPhysicalDescr.2072 = FanentPhysicalDescr.2073 = FanentPhysicalDescr.2080 = Fan SlotentPhysicalDescr.2081 = Cisco cBR Fan AssemblyentPhysicalDescr.2082 = Temp: U17entPhysicalDescr.2083 = Temp: U18entPhysicalDescr.2084 = Temp: FCentPhysicalDescr.2085 = MPL115AentPhysicalDescr.2092 = FanentPhysicalDescr.2093 = Fan

• Example entPhysicalDescr for temperature sensors for CBR-SUP-160G installed in slot 4.entPhysicalDescr.50000 = Cisco cBR CCAP Supervisor CardentPhysicalDescr.50001 = Cisco cBR CCAP Supervisor MBentPhysicalDescr.50141 = Temp: Y0_DIEentPhysicalDescr.50142 = Temp: BB_DIEentPhysicalDescr.50143 = Temp: VP_DIEentPhysicalDescr.50144 = Temp: RT-E_DIEentPhysicalDescr.50145 = Temp: INLET_1entPhysicalDescr.50146 = Temp: INLET_2entPhysicalDescr.50147 = Temp: OUTLET_1entPhysicalDescr.50148 = Temp: 3882_1entPhysicalDescr.50149 = Temp: 3882_2entPhysicalDescr.50150 = Temp: 3882_2AentPhysicalDescr.50151 = Temp: 3882_2BentPhysicalDescr.50152 = Temp: 3882_3entPhysicalDescr.50153 = Temp: 3882_3AentPhysicalDescr.50154 = Temp: 3882_3BentPhysicalDescr.50155 = Temp: 3882_4entPhysicalDescr.50156 = Temp: 3882_4AentPhysicalDescr.50157 = Temp: 3882_4BentPhysicalDescr.50158 = Temp: 3882_5entPhysicalDescr.50159 = Temp: 3882_5AentPhysicalDescr.50160 = Temp: 3882_5BentPhysicalDescr.50161 = Temp: 3882_6entPhysicalDescr.50162 = Temp: 3882_6AentPhysicalDescr.50163 = Temp: 3882_6BentPhysicalDescr.50164 = Temp: 3882_7entPhysicalDescr.50165 = Temp: 3882_8entPhysicalDescr.50166 = Temp: 3882_9entPhysicalDescr.50167 = Temp: 3882_9AentPhysicalDescr.50168 = Temp: 3882_9BentPhysicalDescr.50169 = Temp: 3882_10entPhysicalDescr.50170 = Temp: 3882_10AentPhysicalDescr.50171 = Temp: 3882_10BentPhysicalDescr.50172 = Temp: 3882_11entPhysicalDescr.50173 = Temp: 3882_11AentPhysicalDescr.50174 = Temp: 3882_11BentPhysicalDescr.50175 = Temp: 8314_1entPhysicalDescr.50176 = Temp: 8314_2

6

Page 7: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

entPhysicalDescr.50177 = Temp: 3536_1AentPhysicalDescr.50178 = Temp: 3536_1BentPhysicalDescr.50179 = Temp: AS_DIEentPhysicalDescr.50182 = SUP_dSUM

• Example entPhysicalDescr for temperature sensors for CBR-LC-8D30-16U30 installed in slot 7.entPhysicalDescr.80000 = Cisco cBR CCAP Line CardentPhysicalDescr.80001 = Cisco cBR CCAP Line CardentPhysicalDescr.80014 = Temp: CAPRICAentPhysicalDescr.80015 = Temp: BASESTARentPhysicalDescr.80016 = Temp: RAIDERentPhysicalDescr.80017 = Temp: CPUentPhysicalDescr.80018 = Temp: INLETentPhysicalDescr.80019 = Temp: OUTLETentPhysicalDescr.80020 = Temp: DIGITALentPhysicalDescr.80021 = Temp: UPXentPhysicalDescr.80022 = Temp: LEOBEN1entPhysicalDescr.80023 = Temp: LEOBEN2

Supported SNMP MIBSThe following SNMP MIBs are supported for thermal sensors:

• CISCO-ENVM ON-MIB

• CISCO-ENTITY-ALARM-MIB

• ENTITY-SENSOR-MIB

• ENTITY-MIB

SUP_dSUM AlarmSUP_dSUMalarm is an alarm on the supervisormotherboard of CBR-SUP-250G, CBR-CCAP-SUP-160G, and CBR-CCAP-SUP-60Gline cards. This alarm is a summation of values of the sensors spread across the motherboard. SUP_dSUM alarm is triggered in casessuch as open slots in a chassis that have not been filled properly upon removal of the cards. This alarm is not a temperature sensoralarm but a warning to inspect the system. The SUP_dSUM alarm is displayed in the facility alarm status output and in the SNMPtrap notifications.

Below is an example of the SUP_dSUM alarm:

router#sho facility-alarm status | inc SUPSUP_dSUM R0/192 Jan 19 2016 10:48:32 Critical CHECK FOR OPEN SLOTS & BLOCKED AIR INTAKE [9]

Critical Thermal Sensor Identifiers and Temperature Limit Set-Points forSpecific Line Cards

This section contains only the important sensors and their alarm limits. It does not list all sensors that are displayed when yourun a query with temperature as the criterion.

Note

7

Page 8: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

CBR-SUP-250G: Specific Thermal Sensor Identifier and Temperature Limit Set-Point

System ResponseShutdownCriticalMajorMinorSensor Name

Power Down Card726560NATemp: VP_DIE

Power Down Card57524742Temp: MB_IN_1

Power Down Card57524742Temp: MB_IN_2

Power Down Card103959082Temp: AS_DIE

Power Down Card726560NATemp: Y1_DIE

Power Down Card726560NATemp: Y2_DIE

Power Down Card726560NATemp: Y3_DIE

Power Down Card726560NATemp: Y0_DIE

Just Alarm777063NATemp: Falcon_DIE

Alarm/UINA75NANASUP_dSUM

Just AlarmNA858075Temp: MB_OUT_1

Power Down Card98908580Temp: VP_CHIP

Power Down Card98908580Temp: Falcon_CHIP

Power Down Card918575NATemp:CPU_C0

Power Down Card918575NATemp:CPU_C1

Power Down Card918575NATemp:CPU_C2

Power Down Card918575NATemp:CPU_C3

Power Down Card918575NATemp:CPU_C4

Power Down Card918575NATemp:CPU_C5

Power Down Card918575NATemp:CPU_C6

Power Down Card918575NATemp:CPU_C7

8

Page 9: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

CBR-CCAP-SUP-160G/CBR-CCAP-SUP-60G Motherboard Specific Thermal Sensor Identifierand Temperature Limit Set-Point

System ResponseAt ShutdownLimit (If Enabled)

ShutdownLimit

CriticalLimit

Major LimilMinor LimitIOS Sensor NameCard

Power Down Card726560NATemp: VP_DIECBR-CCAP-SUP-160G

/CBR-CCAP-SUP-60G Power Down Card57524742Temp: MB_IN_1

Power Down Card57524742Temp: MB_IN_2

Power Down Card103959082Temp: AS_DIE

Power Down Card726560NATemp: Y0_DIE

Power Down Card726560NATemp: BB_DIE

Power Down Card777063NATemp: RT-E_DIE

Alarm OnlyNA878075Temp:MB_OUT_1

CBR-CCAP-SUP-160G Daughterboard Specific Thermal Sensor Identifier and Temperature LimitSet-Point

SystemResponseAt ShutdownLimit (IfEnabled)

ShutdownLimit

CriticalLimit

Major LimitMinor LimitIOS Sensor NameCard

PowerDownCard726560NATemp: Y1_DIECBR-CCAP-SUP-160G

PowerDownCard726560NATemp: Y2_DIE

PowerDownCard726560NATemp: Y3_DIE

CBR-2X100G-PIC: Specific Thermal Sensor Identifier and Temperature Limit Set-Point

System ResponseShutdownCriticalMajorMinorSensor Name

Just alarmNA706050Temp:INLET

Just alarmNA908070Temp:RT_OUT

Just alarmNA1059585Temp:MB_OUT

Just alarmNA756555Temp: SUP_OUT

9

Page 10: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

CBR-CCAP-LC-40G Specific Thermal Sensor Identifier and Temperature Limit Set-Point

System Responseat ShutdownLimit (IfEnabled)

ShutdownLimit

Critical LimitMajor LimitMinor LimitIOSSensorNameCard

Power Down Card858075NATemp: CAPRICACBR-CCAP-LC-40G

Power Down Card98908580Temp:BASESTAR

Power Down Card98908580Temp: RAIDER

Power Down Card95908580Temp: CPU

Power Down Card57524742Temp: INLET

Alarm OnlyNA7570NATemp: UPX

Alarm OnlyNA7570NATemp: LEOBEN1

Power Down Card857873NATemp: LEOBEN2

CBR-FAN-ASSEMBLY Specific Thermal Sensor Identifier and Temperature Limit Set-Point

SystemResponse atShutdownLimit(If Enabled)

ShutdownLimitCriticalLimit

Major LimitMinor LimitIOS SensorName

Card

Alarm OnlyNA706560Temp: U17CBR-FAN-ASSEMBLY

Alarm OnlyNA706560Temp: U18

CBR-XX-PS Specific Thermal Sensor Identifier and Temperature Limit Set-Point

SystemResponse atShutdownLimit(If Enabled)

ShutdownLimitCritical LimitMajor LimitMinor LimitIOS SensorName

Card

Alarm Only65605550Temp: INLETCBR-XX-PS

Alarm OnlyNA706560Temp: OUTLET

10

Page 11: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

CBR-DPIC-8X10G Specific Thermal Sensor Identifier and Temperature Limit Set-Point

SystemResponse atShutdownLimit(If Enabled)

ShutdownLimit

Critical LimitMajor LimitMinor LimitIOS Sensor NameCard

Alarm onlyNA756055Temp: INLETCBR-DPIC-8X10G

Alarm onlyNA908070Temp: ZYNQ_OUTLET

Alarm onlyNA908070Temp: SWT_OUTLET

Alarm onlyNA908070Temp: PHY_OUTLET

Alarm onlyNA908070Temp: SFP_OUTLET/OUTLET

11

Page 12: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port

© 2018 Cisco Systems, Inc. All rights reserved.

Page 13: Cisco cBR Router Thermal Monitoring and …...Fan Slot 4 Apr 18 2016 13:05:12 CRITICAL System shutdown will occur in few min [1] Cable3/0-MAC2 Apr 18 2016 13:07:05 INFO Physical Port