chap 3. enb hardware description_stc_ed01_0901

25
Jinyoung Paek Distribution English ED01

Upload: mouhoub-sadaoui

Post on 24-Sep-2015

31 views

Category:

Documents


2 download

DESCRIPTION

eNode B LTE HW

TRANSCRIPT

  • Jinyoung Paek

    Distribution

    EnglishED01

  • 2/25

    Contents

    Main Function of Unit

    Specifications

    Block Diagram

    Digital Unit UAMA, L9CA

    RF Unit L8HU

    Cooling system

    Clock Distribution

    Alarm & Reset Structure

    Interface & Configuration

    RRH Installation

  • 3/25

    Main Function of Unit

    Digital Unit (DU)

    Subscriber data traffic processing

    Call processing, resource allocation and OAM

    GTP, PDCP, OAM, RRC, RRM processing

    Reception of the GPS signal and creation and supply of the clock

    Fault diagnosis and alarm collection and control

    Fast Ethernet/Gigabit Ethernet interface to backhaul

    RLC, MAC/PHY processing

    OFDMA/SC-FDMA channel processing

    RF Unit (RU)

    Up conversion/down conversion of frequency

    High-power amplification of RF transmission signal

    Suppression of out-of-band spurious wave emitted from RF Rx/Tx signal

    Gain control of RF Rx/Tx signal

    Rx/Tx RF signal from/to an antenna

    Low noise amplification of band-pass filtered RF Rx signal

    GTP : GPRS Tunneling Protocol

  • 4/25

    Specifications(1/2)

    Digital Unit spec.

    Category Specification

    Radio Technology TD-LTE Rel. 8/9

    Channel Bandwidth 20MHz

    Capacity Max. 3 channel cards / DU

    Backhaul InterfaceGigabit Ethernet : 4 ports

    (RJ-45 2 ports + SFP 2port)

    Channel Card Capacity 1Carrier 3Sector(4x4) per 1 channel card

    Input voltage -48V DC

    Size(mm) (W x D x H) 434 x 385 x 88 (19 rack mountable)

    Weight(kg) Under 12 kg

    Power Consumption About 200 W (1Carrier/3Sector)

    Cooling Forced Air Cooling

    Temperature 0C ~50C

    Humidity 10~90%

  • 5/25

    Specifications(2/2)

    RF Unit spec.

    Category Specification

    Capacity (max.) 4Tx4Rx, 1Carrier/1Sector (20MHz)

    Operating Frequency 2300~2400 MHz

    Channel Bandwidth 20MHz

    RF Output Power (max.) 10W/path (40W/Unit)

    Cooling Natural convection

    Antenna port N-type female

    Optic port LC/APC connector

    Operating Temp. -40C ~ 50C

    Humidity 5% ~ 95%

    Input Power -48V DC

    Power Consumption < 260W

    Size354mm (W) 112mm (D) 504mm (H)Wall or poll mountable

    Weight Under 20Kg

  • 6/25

    Block Diagram

    Rectifier control (RS-485/FE)

    Power (-48 VDC)

    UAMA

    Analog 10 MHz

    1PPS

    UDA (9Rx/2TX)

    UDE (FE)

    Rectifier

    FE/GE

    Alarm/Control

    CPRI Interface (Optic)

    Clock

    Backhaul

    Data Traffic + Alarm/Control (Ethernet)

    Index

    L8HU

    L8HU

    L8HU

    L9CA

    EPC

    2.5 Gbps CPRI Interface

    GPSUADU

  • 7/25

    Digital Unit - UADU (1/4)

    UADU Description

    Consists of UAMA and L9CA

    Supports the optic CPRI

    Item Quantity Description

    UADU

    UAMA 1

    Universal platform type A Management board Assembly

    - Main processor in the system

    - Resource allocation/operation and maintenance

    - Alarm collection and report to LSM

    - Backhaul support (GE/FE)

    - UADU FAN alarm handling

    - Rectifier interface Connector

    - Provides User Defined Ethernet (UDE) and User Defined

    Alarm (UDA)

    - GPS ANT Input

    L9CA Max. 3

    LTE eNB Channel card board Assembly

    - Call processing and resource allocation

    - OFDMA/SC-FDMA Channel Processing

    - Interface between the L8HU and optic CPRI

    - Support for optic interface with CPRI RRH (E/O, O/E

    conversion in CPRI Mux)

  • 8/25

    Interface

    Digital Unit - UADU (2/4)

    FANM

    ACT GPS RST DBG

    UDA BH0 BH1 UDE0 UDE1 EDBG REC BH2 BH3

    1PPS A10M GPS

    PWR

    RTN PWR/ALM

    L0 L1 L2 L3 L4 L5 ACT RST DBG0 DBG1

    A/F

    -48 V EDBG

    Unit Interface Description

    PWR RTN/-48 V Power Input (RTN/-48 VDC)

    FANM PWR/ALM Fan Module

    UADUs cooling fan

    Dust filter A/F Dust filter

  • 9/25

    Digital Unit UAMA (3/4)Interface

    ACT GPS RST DBG

    UDA BH0 BH1 UDE0 UDE1 EDBG REC BH2 BH3 1PPS A10M GPS

    Unit Interface Description

    UAMA ACT CPU Active LED

    GPS UCCM Status LED

    RST Reset Switch (CPU Chip Reset)

    DBG SW Debug (UART, RS-232)

    UDA User Defined Alarm (Rx: 9 port, Tx: 2 port), Mini Champ

    BH0, BH1 Copper Backhaul (100/1000 Base-T), RJ-45

    UDE0, UDE1 User Defined Ethernet (100 Base-T), RJ-45

    EDBG SW Debug (100 Base-T), RJ-45

    REC Rectifier, RS-485

    BH2, BH3 1000 Base-LX/SX, SFP

    1PPS Test Port 1PPS Output (from UCCM), SMA

    A10M Test Port Analog 10 M Output (from UCCM), SMA

    GPS GPS ANT Input (to UCCM), SMA

  • 10/25

    Digital Unit L9CA (4/4)

    Interface

    L0 L1 L2 L3 L4 L5 EDBGACT RST DBG0 DBG1

    Unit Interface Description

    L9CA ACT L9CA ACT LED

    RST System reset

    DBG0, DBG1 UART DSP Debug, USB

    L0~5 L8HU IF (CPRI 4.0), Optic

    EDBG SW Debug (UART, RS-232)

  • 11/25

    RF Unit L8HU(1/3)

    RF Unit Description

    The RRH is that integrates the transceiver, power amplifier, and filters in a single module.

    Category Specification

    Capacity (max.) 4Tx4Rx, 1Carrier/1Sector (20MHz)

    Operating Frequency 2300 ~ 2400MHz

    Channel Bandwidth 20MHz

    RF Output Power (max.) 10W/path, 40W/unit

    Cooling Natural convection

    Operating Temp. -40C ~ 50C

    Input Power -48VDC

    Size354mm (W) 112mm (D)

    504mm (H)

    Weight Under 20kg

    Installation Wall /pole

    4T4R RRH

    RRH : Remote Radio Head

  • 12/25

    RF Unit L8HU(2/3)

    Power

    Port

    Debug

    Access PortOptic

    Port

    RF_ANT

    Port_3

    RF_ANT

    Port_2

    RF_ANT

    Port_1

    RF_ANT

    Port_0

    RET

    Port

    [Bottom View]

    [Front View] [Right View]

    [Top View]

    [Left View]

    143.5

    354

    370

    504

    520

    112

  • 13/25

    RF Unit L8HU(3/3)

    -48 V INOPTIC RET DEBUG

    ANT_3 ANT_2 ANT_1 ANT_0

    Interface Description

    -48 V IN Power Input (-48 VDC)

    OPTIC DADU interface, ODCP (LC type)

    RET Remote Electrical Tilt (AISG 2.0)

    DEBUG S/W debug, Mini USB

    ANT_0~3 4Tx/4Rx, N-type female

  • 14/25

    Cooling System

    UADU

    The UADU maintains the inside temperature of the shelf at an appropriate range using a set of

    system cooling fans (FANM)

    L8HU

    The L8HU is designed with a natural cooling system that supports an outdoor environment with

    no additional fan or heater

    FANM is designed to control RPM automatically according to temperature..Dust Filter is only included when inserting UADU at Indoor Open Rack

    FANM Dust Filter

    UADU : Universal platform type A Digital Unit

    L8HU : LTE eNB remote radio Head Unit

  • 15/25

    Synchronization

    GPS synchronization

    The UCCM receives the synchronization signals from the GPS and generates clocks and

    distributes them within the UADU

    Clock Generation &

    Distribution UCCM

    Control

    GPS

    UADUSYS(System Clock 30.72MHz)

    SFN(System Frame Number)

    PP2S(Even Clock)

    Digital 10MHz

    PP2X(Even Clock)

    Analog 10MHz1PPS

    Test Equipment

    UCCM : Universal Core Clock Module

  • 16/25

    Alarm and Reset Structure

    Alarm and Reset

    When an environmental fault occurs or H/W is mounted or unmounted, it is reported

    using an alarm signal

    All alarms are collected in the DU and reported to the management system, LSM

    UAMA

    L9CA

    GPS Module (in UAMA)

    L8HU #2

    L8HU #0

    : Reset

    : Alarm

    : Remote Pattern Reset

    LSMC

    B A

    A

    B

    C

  • 17/25

    Interface & Configuration(1/2)

    RRH Cable

    (Optic Cable-2.5Gbps)

    Copper

    Back-Haul

    (2EA)

    UDE

    (2EA)

    SW debugOptic

    Back-haul

    (2EA)

    UDA

    1pps

    Analog

    10MHz

    Rectifier IF

    GPS Antenna

    SW debug

    LED

    (GPS)

    LED

    (CPU) Rectifier

    Power cable

    SW debug

    (2EA)

    Board

    Reset

    CPU State

    LED

    System

    Reset

    SW debug

  • 18/25

    Interface & Configuration(2/2)

    1 DU + 3 RRH Configuration

    Supports 20MHz 4T4R 1carrier

    3sectors

    Two 2.5Gbps CPRI cables are

    required for 20MHz 4T4R

    configuration

    g - sector(4T4R TD-LTE)a - sector

    (4T4R TD-LTE)

    b - sector(4T4R TD-LTE)

  • 19/25

    RRH Installation 1Sector Pole Mount

    wall

    RRU

    RRU

    RectifierRectifier

  • 20/25

    RRH Installation 1Sector Floor Mount

  • 21/25

    RRH Installation 1Sector Wall Mount

    Wall

    RRU

    Rectifier

  • 22/25

    RRH Installation 3Sector Pole Mount

    wall

    RRU

    RRU

    RRU

    RRU

    RRU

    RRU

    RRU RRU

    RRU

  • 23/25

    RRH Installation 3Sector Floor Mount

    RRU

    RRU

    RRURRU

    RRU

    RRU

  • 24/25

    RRH Installation 3Sector Wall Mount

    RRU

    RRU

    RRU

    RRU

    RRU

    RRU