CHAMPION HEIGHTS COMMERCIAL BUILDING
ERIC BEALSRYAN KRAUSE
CAMERON MILLERRANDY RODRIGUEZ
HORACIO MONTEJANO
![Page 2: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/2.jpg)
CHAMPION HEIGHTS COMMERCIAL BUILDING
Purpose:The goal of our project is to design a commercial building to meet the needs for the growing community of Boerne, TX.
Scope:• Design of 63,000sf concrete building• Drainage and Detention study• Onsite Parking Area, Drainage, Water, Sewer
Improvements• Offsite Streets, Drainage, Water, and Sanitary Extension
Improvements.• Construction Documents
Eric Beals
![Page 3: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/3.jpg)
SITE LOCATION
Eric Beals
![Page 4: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/4.jpg)
PROPOSED SITE LAYOUT
Eric Beals
![Page 5: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/5.jpg)
DESIGN SCHEDULE
PRIMAVERA P6 DESIGN SCHEDULE • Planning• Monitoring• Reporting Horacio Montejano
![Page 6: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/6.jpg)
BUILDING SPECIFICATIONS
• 3 Floors• 63,000 SF office
building
• Glass, Stucco and brick exterior
Ryan Krause
![Page 7: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/7.jpg)
LOADS AND ANALYSIS
• Loads Considered:• Dead• Live• Wind
• Code used:• ASCE 7-10
• Drawings done with:• AutoCAD Civil 3D 2011• Google SketchUp
• Analysis done with:• SAP2000 15
• Rain• Snow• Seismic
Ryan Krause
![Page 8: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/8.jpg)
ENVIRONMENTAL
• Must Follow Texas Commission on Environmental Quality Guidelines • Minimal Tree Removal • No Indications of
Hazardous Materials or any Area of Contamination
Randy Rodriguez
![Page 9: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/9.jpg)
GREEN DESIGN Green Building Materials:
• 10% Fly Ash incorporated into foundation• Use of Local Materials encouraged• Contractors must provide construction
waste management plan Optional Roof Garden:
• Native Drought resistant Plants to absorb CO2
Energy Efficient Appliances:• Low Flow Toilets• Low Flow Faucets• Waterless Urinals• LED Lighting W/ Motion SENSORS• Up to 30% in energy & water
savings expected!
Horacio Montejano
![Page 10: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/10.jpg)
BORING LOG
1
2
2. SHALLOW LIMESTONE STRATA1. HIGH PLASTICITY INDEX
Horacio Montejano
![Page 11: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/11.jpg)
FOUNDATION ANALYSIS
12345678
• Divide foundation layout into 8 strips • Analyze each strip for the shear & moment developed by the line of column loads
Horacio Montejano
![Page 12: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/12.jpg)
FOUNDATION ANALYSISDetermine: Effective depth of Shear Prism for
diagonal tension shear
Maximum Positive & Negative Moments (Interior & Exterior)
Steel reinforcement
@ pu(max)=577.55 Kips; D=20”
(+) Interior = 1269.97 k-ft(-) Interior = 186.05 k-ft(+) Exterior = 958.21 k-ft(-) Exterior = 109.75 k-ft
• Conventional Grade 60 Rebar
Horacio Montejano
![Page 13: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/13.jpg)
FOUNDATION DESIGN Foundation Type Selected:
BEAM & SLAB Foundation (Slab is suspended)!
WHY?• Simple Economics:
Less Steel+Less ConcreteSavings!
• Rigid Design• Reduction in Differential
Settlement
• High F.S.
• Eases Construction
• Floor slab is entirely isolated from expansive soils Horacio Montejano
![Page 14: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/14.jpg)
STRUCTURAL OVERVIEWOffice Building 3-Stories:• Concrete Structure• Decking (One-Way Joist 2’ Module)• Braced Frame (CMU Walls)
Randy Rodriguez
![Page 15: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/15.jpg)
CIVIL DESIGN• Grading• Existing conditions 8’ elevation change• Proposed conditions 3’ Change in elevation (parking
grade .5%)• 3’ deep detention
Eric Beals
![Page 16: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/16.jpg)
CIVIL DESIGN• Storm Detention • 98,000 cubic feet• 12” outlet• 1’ freeboard
Eric Beals
![Page 17: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/17.jpg)
CIVIL DESIGN• SW3P • 662LF OF Silt Fence• 3 Rock Filter Berms
Eric Beals
![Page 18: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/18.jpg)
UTILITY LAYOUT
Water R.O.W. regulation 12-inch main extension
boring under HWY 46. Total Length 438 LF 3-inch water lateral
Service demand 14 edus
Sewer 8-inch 5.8% slope Capacity 251 edus
Cameron Miller
![Page 19: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/19.jpg)
PAVEMENT DESIGN
From Geotech Report and Analysis S.N.-2.22 Concrete Asphalt Layer
2-inch Base Layer
8-inches
Cameron Miller
![Page 20: CHAMPION HEIGHTS COMMERCIAL BUILDING](https://reader035.vdocuments.us/reader035/viewer/2022081517/568165a4550346895dd88544/html5/thumbnails/20.jpg)
COST ESTIMATE
Cameron Miller