What is Manufacturing Variation?
Imperfections in geometry and clearances between
parts cause undesirable adjustments within assemblies
![Page 3: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/3.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
What is CETOL 6 Addressing?
The assembly-level
tolerance is driven by:
1) Part-level dimensioning &
tolerance scheme
2) Assembly-level kinematic
relationships between
contacting surfaces
![Page 4: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/4.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
Input Variables from CETOL 6
CETOL is driven by an XML-based
model file (.CXM)
– Created using the CETOL Modeler
– Rich with unique assembly constraint
and tolerance variables
Input Variables to Optimus
– Size, dimension, & GD&T tolerances
– Feature sizes & positions
– Design nominal values
– Design nominal manufacturing
distribution parameters
![Page 5: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/5.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
CETOL 6 Output Variables
Geometric variation-related analysis
results for each measurement
1) Quality metrics (Cp, Cpk, sigma, % yield, etc)
2) Worst-case variation limits
3) Statistical distribution parameters
4) Calculated nominals
5) Geometric sensitivities
6) Percent contributions
7) …
![Page 6: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/6.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
Basic CETOL Simulation Workflow
Ascii-format CXM file,
parsed by Optimus
CXM format converter
Native CETOL CXM file
Run CETOL Analysis
Ascii-based results file,
parsed by Optimus
![Page 7: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/7.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
Common Applications
Include mechanical variation effects in:
1) Multi-objective performance optimization
2) Multi-physics simulation and optimization
3) Design robustness optimization
4) Manufacturing cost optimization
![Page 8: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/8.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
CETOL Example
![Page 9: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/9.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
1) Multi-Objective Optimization
Objective: Determine the design tolerance values that
achieve the quality targets of multiple, conflicting design goals
Optimus adjusts Part
tolerances to achieve target
quality for all measurements
CETOL calculates Cable
force offset, Claw to tip
clearance, etc. quality
metrics
![Page 10: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/10.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
2) Multi-Physics Optimization
Objective: Determine largest design tolerance values
that still achieve the optical cell focal length & center-
line error maximum variation requirement
CETOL calculates air
gap, tilt, & de-center
variation
External Optical
Analysis Tool
i.e. CODE 5
![Page 11: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/11.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
3) Robustness Optimization
Objective: Find the location of the Claw hole feature that
minimizes the claw force sensitivity to manufacturing
variation.
CETOL calculates
Claw Force Offset
variation
External Force
Analysis Tool
![Page 12: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/12.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
4) Manufacturing Cost Optimization
Objective: Determine the design tolerance values that
minimize the total cost of manufacturing the seat latch
CETOL calculates Cable
force offset, Claw to tip
clearance, etc. variation
Part tolerance, variation
results, & other cost
inputs fed to external
cost estimation tool
![Page 13: CETOL 6 Integration with Optimus - sigmetrix.com](https://reader030.vdocuments.us/reader030/viewer/2022012805/61bd3a0861276e740b109ee6/html5/thumbnails/13.jpg)
Copyright Sigmetrix, LLC 2010
All Rights Reserved www.sigmetrix.com
CONFIDENTIAL ZERO TOLERANCE FOR ERROR
CETOL 6 and Optimus
Analyze. Optimize. Understand.