centrepoint theatre technical specification tech spec2.pdf · ductac, mall of the emirates, dubai,...

9
DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013 DUCTAC CENTREPOINT THEATRE TECHNICAL SPECIFICATION Technical Manager: Craig Burgess | [email protected] | +971 (0) 4341 4777 ext 329 Chief Technician: Philip Fortaleza | [email protected] | +971 (0) 4341 4777 ext 218 Technician: Anthony Manalo | [email protected] | +971 (0) 4341 4777 ext 334

Upload: trandung

Post on 12-Mar-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

DUCTAC

CENTREPOINT THEATRE

TECHNICAL SPECIFICATION

Technical Manager: Craig Burgess | [email protected] | +971 (0) 4341 4777 ext 329 Chief Technician: Philip Fortaleza | [email protected] | +971 (0) 4341 4777 ext 218

Technician: Anthony Manalo | [email protected] | +971 (0) 4341 4777 ext 334

Page 2: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Seating Our main auditorium is tiered on two levels (Stall and Balcony) and has the capacity of 543. Provision is made for four wheelchair usage. Our first two rows are removable to facilitate an orchestra pit. Also there are two VIP boxes (4 seats each) situated on both side of the balcony, two VIP boxes (8 seats each) at rear of stall next to both side of the technical control room.

Stage Flat built timber covered sprung floor painted black with 12m x 7.2 m proscenium opening Performing area: 12m W x 10.8m D x 15 m to grid. 17.5 to hanging points (RSJ) Wing space: S.L. 3.2m W x 8 m D x 6 m H; S. R. 3.3m W x 9 m D x 6 m H Communication Stage Manager’s desk is located at Stage Left with cast call paging system, cue light control and clear COM talkback system. Six intercom lines with headsets can be installed at control box (2 points), SR, SL. Fly floor or Follow spot room. Flying System 6 counterweighted bars (SWL 350 kg) – Operated on the SL gallery 5 motorized bars (SWL 350 kg) – Fixed control panel DSL 1 motorized bar with cyclorama/blacks (SWL 350 kg) 4 hemp bars (SWL 350 kg) – tied off on the SR gallery 2 hand winched bars in wings (6x available lighting ladders) 10 3m Fixed bars for legs (Masking) Masking and soft Hanging 1 set of red velvet house tabs (permanent attachment) 1 set of black mid-stage tabs (permanent attachment) – dead hung 5 sets of black soft legs (3m x 8m - fixed) – dead hung 3 Black soft borders (3m x 16m) 1 White cyclorama (16m x 7m) 1 Black backdrop (16m x 8m) 1 Black gauze (16m x 8m) Get-In / Access All vehicles arriving must be less than 2.8m high to park/unload on level 2 (DUCTAC) Loading platform is 0.75m above driveway level with roller shutter door of 4m wide / 6m height Larger vehicles can unload at Loading Bay 10 and use the large lifts to get to level 2 (DUCTAC) Lift door size is 2.40m (7.87ft) x 2.40m (7.87 ft). Maximum lift load is 5000 kg. Dock is Large and has easy access to stage with high scenic doors

Page 3: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Sound Control room is located at the rear of the stalls. Console:

MIDAS Pro2c digital console including 8 integral mic/line inputs with MIDAS mic preamps, 64 simultaneous input processing channels, 8 VCA’s, 6 POP groups. For more info: www.midasconsoles.com

Stage box/facility panels:

1 MIDAS DL521 I/O box. 48 Inputs & 16 Outputs 4 fixed panels located - USL (8 In & 4 Out), DSL (12 In & 4 Out), USR (8 In & 4 Out), DSR (12 In & 4 Out).

Sound System: VQnet Software controls the main system. This is networked with VQnet enabled cabinets giving full control via a computer located in the control room, next to the main sound console. Main System: 2x Tannoy VQnet 60. 2x Tannoy VQnet 218 Centre Cluster: 2x Turbosound TQ 315 Crown IT Series amplifiers Front Fills: 4x Turbosound TCS-35 Crown IT Series amplifiers Balcony: 3x Turbosound TCS-40 Crown IT Series amplifiers On Stage Foldback/Monitoring: 4x Turbosound TFM 212 (Wedge) 2x Turbosound TQ 315 & 2x Turbosound TQ 425 (Side Fills) Crown IT Series amplifiers Microphones: 4 Shure SLX Wireless 84 Lavaliere/Lapel with belt pack - HIRE CHARGE AED 200 per day 4 Shure SLX Wireless SM 58 & 4 BETA 58 Handheld - HIRE CHARGE AED 200 per day 6 Sennheiser MKE 1 Wireless with belt pack – HIRE CHARGE AED 350 per day 2 Sennheiser MEG 14-40 B Gooseneck – HIRE CHARGE AED 40 per day 5 Shure SM 58 – HIRE CHARGE AED 40 per day 6 Shure SM 57 – HIRE CHARGE AED 40 per day 4 Shure BETA 87A – HIRE CHARGE AED 60 per day 2 Shure SM 81-LC – HIRE CHARGE AED 60 per day 1 Shure BETA 52A – HIRE CHARGE AED 60 per day 3 Crown PCC 160 – HIRE CHARGE AED 60 per day 4 DPA 4060 FM head-set – HIRE CHARGE AED 90 per day 8 DPA 4098HB hanging mic – HIRE CHARGE AED 50 per day 16 K&M tall boom mic stands, 4 K&M short boom mic stands

Page 4: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Outboard: Yamaha SPX2000 1 KLARK TEKNIK Parametric EQ 1 KLARK TEKNIK Compressor 6 KLARK TEKNIK 31 Band EQ Playback equipment: 1 Sony CD player 1 Tascam 350 Mini disc recorder 2 Tascam 112MKII cassette recorders Audio Recording: A stereo mix from the console can be recorded in digital formats. Please note advance notice is required for set up. – HIRE CHARGE AED 500 per day Lighting Control room at rear of stalls Consoles: ETC ION – 20 fader sub master wing, itouch remote, fully networked, 2 DVI screens Strand 300 Classic Palette – 250 channels, 24 sub master, Tracker, Net worker, WYSIWIG Martin M2GO – 4 DMX universes, 1000 cue lists, Submaster, Groupmaster and Override functionality. Luminaries Hui Flood 24 1000w Rama PC 15ْ – 6ْ 12 1200w 7 – 55 Rama PC 15 -6 Fresnel 20 1200w 5 – 60 Pacific Profile 16 1200w 14 – 35 Pacific Profile 6 1200w 12 – 28 Pacific Profile 6 VNZ 1200w Profile 4 26 600 W Profile 4 23 – 50 600 W Profile 4 15 -32 600 W Par 64 12 1000w Arena 6 2500w spot – flood Arena 6 2000w spot - flood Robe Spot 250 AT 8 250 W moving yoke lighting fixture – HIRE CHARGE AED 100 Martin MAC Aura 16 LED wash fixture – HIRE CHARGE AED 150 per unit / per day Altman Spectra 200-CYC 10 LED CYC wash fixture Clay Paky Shadow ST 2 Follow Spot 1200 W full colour changing – HIRE CHARGE AED 350 Colour Scroller 15 15 Colour scroller Martin Atomic 3000 1 DMX Strobe Light 3000W Blues/Working Light Blue LED fixtures are installed in the control room and in each wing for show working light – The stage has fluorescent strip lighting for working light during fit up’s and get out’s Accessories and Effects 1 JEM ZR33 Hi Mass Smoke – HIRE CHARGE AED 300 per day 1 Martin Magnum Hazer Machine – HIRE CHARGE AED 300 per day 15 Metro-deck stage units (Different size legs available) – HIRE CHARGE AED 80 per day Acrylic Lectern (Including goose neck microphone) – HIRE CHARGE AED 100 per day

Page 5: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Harlequin Dance Floor (Black/Grey) – HIRE CHARGE AED 1,300 per day

Projection

Eiki LC-XT3 - LCD Projector XGA 10,000 ANSI lumens mid throw zoom lens – HIRE CHARGE AED 2,000 LG - DVD/VCR player PC Laptop / Macbook Pro – HIRE CHARGE AED 250 per day Resolution of projection = 1024 x 768 ONLY DVD, VHS or LAPTOP (VGA) formats will be accepted 4.5m / 6m projection screen (Front projection) Power Stage Left – 1x 32a Single Phase (Sound Only), 1x 63a Three Phase, 1x 16a Single Phase, 13a Sockets (Various) Stage Right – 1x 32a Single Phase (Sound Only), 1x 63a Three Phase, 13a Sockets (Various) Control Room – 13a sockets only (Various) Scene Dock – 3x 16a Single Phase, 3x 32a Three Phase, 13a sockets (Various) FOH – 13a sockets only (Various) Dressing Rooms/backstage Dressing rooms: Total 7, all equipped with ablutions, can accommodate up to 104 performers With show relay/cast paging. Wardrobe: 1 washing machine, 1 dryer, 10 hanging rails Dressing Room Dimensions and Capacity Below shows the Maximum capacity all Dressing rooms & Wardrobe. Dressing Room 1, 2, 3 and 4 4520mm (14.83ft) x 5275mm (17.31ft) = 256.71 ft2 / 36 = 7 people only. We can round off this to 10 people only. Dressing Room 5 5390mm (17.68ft) x 7725mm (25.34ft) = 448 ft2 / 36 = 12 people only or we can round this off to 15 people only. Dressing Room 6 7960mm (26.11ft) x 4295mm (14.09ft) = 367.89 ft2 / 36 = 10 people only or we can round this off to 13 people only. Dressing Room 7 5390mm (17.68ft) x 3400mm (11.15ft) = 197.13 ft2 / 36 = 5 people only. Wardrobe 10,380mm (34.05ft) x 9095mm (29.83ft) = 1,015 ft2 / 36 = 28 people or we can round this off to 31 people only. TOTAL of 104 people only. Centrepoint Theatre Stage Regulations for Visiting Companies

• No Live naked Flames (Candles/Torches etc)

Page 6: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

• No access to Control Room, Fly floors, Bridges & Grid areas without DUCTAC Technical staff supervision

• No rigging from the Grid unless discussed with the Technical Manger and Risk assessed • Flying counterweight or motorized systems should only be operated by DUCTAC Technical staff (If

flying is required during your show please give advance warning so staff can be allocated) • No water pools or water effects • Pyrotechnic and smoke effects should be discussed in advance with the Technical Manager • Use of compressed gasses must be discussed in advance with the Technical Manager • Use of the Tallescope and other access equipment may only be used by DUCTAC staff unless

otherwise agreed • A ‘pre-rig’ may not always be achieved before your arrival – Please send Lighting/Stage plans

ASAP to help us prepare for you • Please give advance warning for deliveries (We need to seek permission from the mall security) • Get out’s should start immediately after the show, removing Sets off site unless agreed by the

Technical manager (We do not have space to store Sets/Props) • No eating or drinking on stage, control room & Auditorium • Health & Safety is taken very seriously in our venue and we reserve the right to cancel the show if

we do not deem it safe • No camera JIB’s / Cranes allowed in the auditorium • External lighting fixtures must be supplied with rated safety bonds/chains

Page 7: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Page 8: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

Page 9: CENTREPOINT THEATRE TECHNICAL SPECIFICATION Tech Spec2.pdf · ductac, mall of the emirates, dubai, uae, po box 117748 updated october 2013 ductac centrepoint theatre technical specification

DUCTAC, MALL OF THE EMIRATES, DUBAI, UAE, PO BOX 117748 UPDATED OCTOBER 2013

LOADING BAY 10 MAP