center for quantum information and control

19
Center for Quantum Information and Control Quantum control and feedback: A circuit-based perspective I. Is there a problem? II. Measurement-based and coherent control III.True quantum Noncommutative control and feedback Carlton M. Caves Center for Quantum Information and Control, University of New Mexico Centre for Engineered Quantum Systems, University of Queensland http://info.phys.unm.edu/~ caves Co-workers: J. Combes, G. J. Milburn

Upload: walden

Post on 22-Feb-2016

30 views

Category:

Documents


0 download

DESCRIPTION

Quantum control and feedback: A circuit-based perspective Is there a problem? Measurement-based and coherent control True quantum Noncommutative control and feedback Carlton M. Caves Center for Quantum Information and Control, University of New Mexico - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Center for Quantum Information and Control

Center for Quantum Information and Control

Quantum control and feedback:

A circuit-based perspective I. Is there a problem?

II. Measurement-based and coherent controlIII. True quantum Noncommutative control and feedback

Carlton M. CavesCenter for Quantum Information and Control, University of New Mexico

Centre for Engineered Quantum Systems, University of Queenslandhttp://info.phys.unm.edu/~caves

Co-workers: J. Combes, G. J. Milburn

Page 2: Center for Quantum Information and Control

I. Is there a problem?Cable Beach

Broome, Western Australia

Page 3: Center for Quantum Information and Control

Examples and questions

Haroche lab: C. Sayrin et al., Nature 477, 73 (2011).

Feedforward? Feedback? Measurement-based control? Coherent control?Quantum control?

M. R. James, H. I. Nurdin, and I. R.~Petersen, IEEE Trans. Auto. Control 53, 1787 (2008).H. Mabuchi, Phys Rev A 78, 032323 (2008).

JNP-M

Page 4: Center for Quantum Information and Control

Classical control and feedback

Feedback control

Open-loop control

Feedforward

Iterative learning

Classical control diagrams do not (quantum circuit diagrams do)1. Cleanly distinguish systems from their interactions.2. Display both temporal (causal) and spatial (subsystem) relations.

A quantum circuit displays the interactions between the single degrees of freedom that process quantum information.

Michael Nielsen (c. 1998): Carl, you should learn how to use quantum circuits.

Page 5: Center for Quantum Information and Control

Messages1. All measurement-based control and feedback can be

converted to coherent quantum control. 2. Not all coherent quantum control can be converted to

measurement-based control: control on noncommuting observables cannot be so converted and is something different.

3. Quantum feedback is distinguished from feedforward by the presence in a quantum circuit of interfering quantum paths that begin and end on the plant.

Page 6: Center for Quantum Information and Control

II. Measurement-based and coherent control

Pinnacles National ParkCentral California

Page 7: Center for Quantum Information and Control

Classical diagram

Quantum circuit Coherent version

Plant: persisting quantum systemController: classical information processorDesired behavior: successive inputsDisturbances: successive quantum systems

Open-loop

control

Repetitive elements

Page 8: Center for Quantum Information and Control

Classical diagram

Quantum circuit (disturbances omitted)

Open-loop

control

Quantum circuits generally omit classical open-loop controls, so this circuit reduces to

Objective: synthesize plant state or unitary or quantum operationMeasures of efficacy: efficiency, robustness

Page 9: Center for Quantum Information and Control

FeedforwardClassical diagram

Plant: atoms, optical or microwave cavity, mechanical oscillatorProbes and disturbances: successive quantum systems that interact with one another and with the plant, e.g., field modes, atoms, qubits, qudits (Markovicity?)Controller: omitted

probe jr3i £ M ²

probe jr2i £ M ²

probe jr1i £ £

plant ½

disturbance ¾1 £ £

disturbance ¾2 £

disturbance ¾3 £

Measurement-based quantum circuit

Page 10: Center for Quantum Information and Control

Feedforward probe jr3i £ M ²

probe jr2i £ M ²

probe jr1i £ £

plant ½

disturbance ¾1 £ £

disturbance ¾2 £

disturbance ¾3 £

Measurement-based quantum circuit

No feedback onto plant: no multiple (interfering quantum) paths that begin and end on the plant.

Use the Principle of Deferred Measurement to push the measurements through the associated controls to the end of the circuit, where they can be omitted.

probe jr3i £ ² M

probe jr2i £ ² M

probe jr1i £ £

plant ½

disturbance ¾1 £ £

disturbance ¾2 £

disturbance ¾3 £

Coherent version

R. B. Griffiths and C.-S. Niu, PRL 76, 3228 (1996).

Page 11: Center for Quantum Information and Control

Feedforward onto probesprobe jr4i £

probe jr3i £ M ²

probe jr2i £ M ² ²

probe jr1i £ £ £

plant ½

Measurement-based quantum circuit

Coherent version

probe jr4i £

probe jr3i £ ² M

probe jr2i £ ² ² M

probe jr1i £ £ £

plant ½

Page 12: Center for Quantum Information and Control

Direct feedback

Classical diagram

Plant: atoms, optical or microwave cavity, mechanical oscillatorProbes: successive quantum systems that interact with one another and the plant, e.g., field modes, atoms, qubits, quditsDisturbances and controller: omitted

Measurement-based quantum circuit

probe jr3i £ M ²

probe jr2i £ M ²

probe jr1i £ £

plant ½

Page 13: Center for Quantum Information and Control

Measurement-based quantum circuit

probe jr3i £ M ²

probe jr2i £ M ²

probe jr1i £ £

plant ½

Direct feedback

probe jr3i £ ² M

probe jr2i £ ² M

probe jr1i £ £

plant ½

Coherent version

Use the Principle of Deferred Measurement to push the measurements through the associated controls to the end of the circuit, where they can be omitted.

Feedback: multiple (interfering quantum) paths that begin and end on the plant.

Feedback loop

Page 14: Center for Quantum Information and Control

Indirect feedbackMeasurement-based

quantum circuit

Coherent version

Feedback: multiple (interfering quantum) paths that begin and end on the plant.

Page 15: Center for Quantum Information and Control

Moo Stack and the Villians of UreEshaness, Shetland

III. True quantum Noncommutative control and feedback

Page 16: Center for Quantum Information and Control

Controlled unitaries

H. M. Wiseman and G. J. Milburn, PRA 49, 4110 (1994).

But what aboutNoncommuting (say, mutually unbiased, or conjugate) bases

Page 17: Center for Quantum Information and Control

Noncommutative control

Plant cavity mirrors

Mirror interaction

JNP-M

Page 18: Center for Quantum Information and Control

Noncommutative controlMirror

interaction

Inequivalentcommuting

control

Page 19: Center for Quantum Information and Control

That’s all, folks! Thanks for your attention.

Western diamondback rattlesnakeSandia Heights, New Mexico

1. All measurement-based control and feedback can be converted to coherent quantum control.

2. Not all coherent quantum control can be converted to measurement-based control: control on noncommuting observables cannot be so converted and is something different.

3. Quantum feedback is distinguished from feedforward by the presence in a quantum circuit of interfering quantum paths that begin and end on the plant.