cascade co2_nh3 refrigeration
TRANSCRIPT
-
7/25/2019 Cascade Co2_nh3 Refrigeration
1/34
ASustainableRefrigeratingSystem
forthePRWIndustry
2012Heartland
Chapter
Meeting
Chicago,IL.October34,2012
CascadeCO2
/NH3
Refrigeration
-
7/25/2019 Cascade Co2_nh3 Refrigeration
2/34
RefrigerationThen
1924 Ball Horizontal Dual Acting Compressor
2
-
7/25/2019 Cascade Co2_nh3 Refrigeration
3/34
RefrigerationThen
Rotary Blade Booster
Compressors
Reciprocating High Stage
Compressors
3
-
7/25/2019 Cascade Co2_nh3 Refrigeration
4/34
RefrigerationNow
Screw Compressor and Reciprocating Compressor
4
-
7/25/2019 Cascade Co2_nh3 Refrigeration
5/34
ModernRefrigerationEngine
Room
Cascade CO2/NH3 System
5
-
7/25/2019 Cascade Co2_nh3 Refrigeration
6/34
ShouldIChoseCO2
(R744)formyRefrigerating
System? Whattemperaturesdoyouneedtomaintain?
Arethereproductfreezingrequirements?
IsmaintainingareducedAmmoniasystem
chargecritical?
Isno
contaminating
refrigerants
in
the
food
storage,processingandemployeeworkareas
desirableor
needed?
And,isprovidingaGreen
refrigeration
system
important?
6
-
7/25/2019 Cascade Co2_nh3 Refrigeration
7/34
RefrigerationSystem FirstCost
SingleStageEconomizedSystem(Lowest)
CascadeCO2
/NH3
System(Mid
Range)
TwoStageAmmoniaSystem(Highest)
7
-
7/25/2019 Cascade Co2_nh3 Refrigeration
8/34
Independent3rd
PartyStudySystem Efficiency Results
Cascade CO2 vs. Two Stage NH3
8
-
7/25/2019 Cascade Co2_nh3 Refrigeration
9/34
Independent3rd
PartyStudy
2StageNH3
Reference
System[kW/TR]
CO2/NH3
CascadeSystem
[kW/TR]
%Improvement
InEfficiency
20FSuctionGroup 0.8 0.7 12.3
58FSuctionGroup 1.6 1.0 37.3
Combined
20Fand
58F
Suction
Groups 1.2 0.9 28.7
HighTempSuctionGroup 0.7 0.8 8.5
TotalSystemkW/TR(Compressors) 1.7 1.6 8.1
Total
System
kW/TR
(Compressors
and
Condenser) 1.9 1.8 6.8
TotalSystemkW/TR(Compressors,
CondenserandAirUnits) 2.4 2.3 5.8
System Efficiency Results
Cascade CO2 vs. Two Stage NH3
9
-
7/25/2019 Cascade Co2_nh3 Refrigeration
10/34
FieldTestMeasurement/Instrumentation
Flow Meters
10
-
7/25/2019 Cascade Co2_nh3 Refrigeration
11/34
CO2
SystemAdvantagesOperating
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
-70 -65 -60 -55 -50 -45 -40 -35 -30 -25 -20
COP
Evaporating temp [deg F]
COP comparison of CO2/Ammonia withconventionel Ammonia Systems at full load
CO2/AmmoniaDT cascade = 9F
Single stage withopen economizer
Two stage withopen inter-midiate cooler
11
-
7/25/2019 Cascade Co2_nh3 Refrigeration
12/34
CO2
SystemAdvantagesOperating
COP comparison of CO2/Ammonia with
conventionel Ammonia Systems at 50% load
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
-65 -60 -55 -50 -45 -40 -35 -30 -25 -20
Evaporating temp [deg F]
COP
CO2/Ammonia
DT cascade = 6F
Single stage with
open economizer
Two stage with
open inter-
midiate cooler
12
-
7/25/2019 Cascade Co2_nh3 Refrigeration
13/34
CO2
SystemAdvantagesOperating
13
-
7/25/2019 Cascade Co2_nh3 Refrigeration
14/34
CO2
SystemAdvantagesOperating
14
-
7/25/2019 Cascade Co2_nh3 Refrigeration
15/34
CO2
SystemAdvantagesOperating
15
-
7/25/2019 Cascade Co2_nh3 Refrigeration
16/34
RefrigerationSystem
Ammoniacompressor
CO2
compressor
Ammoniacondenser
CO2
/NH3
heatexchanger(cascade
cooler)
CO2
receiver(pump
separator)
CO2
evaporator
CO2
liquidpump
16
-
7/25/2019 Cascade Co2_nh3 Refrigeration
17/34
CO2
Application ColdStorage
NH3 Surge
Drum
NH3 Screw
11 / 95F
Evap. Condenser
CP-Receiver
(Economizer)NH3/CO2 Cascade
Heat Exchangers
CO2
VPR
-55F
CO2
VPR
-30F
Blast FreezerFreezer
NH3 Screw
11 / 95F
CO2 HPR
20FCO2 Recip
-55/ 20F
CO2 Recip-55/ 20F
CO2 Recip
-30/ 20F
CO2 Recip-30/ 20F
Drier
CoolerDock
OilRectifier
OilRectifie
r
17
-
7/25/2019 Cascade Co2_nh3 Refrigeration
18/34
CO2
SystemsBackgroundDrivers
Refrigerantsituation
Ammoniacharge
restrictions
Ammoniasdamagingeffects
Electricity
costs Lowerfirstcost
Refrigerant
cost Lowertemperaturesatreasonablecosts
Lessspacerequired
18
-
7/25/2019 Cascade Co2_nh3 Refrigeration
19/34
CO2
SystemsFactsonCO2
(R744)
CO2
isalreadyintheatmosphere
CO2
isnon
toxic
and
non
flammable
CO2
isusedtoputoutfires
A
major
leak
will
not
damage
products OnlyCO2
snow(DryIce)willfalldownon
products
Dryicesublimatetovaporandwillnotleavea
wetsurface
19
-
7/25/2019 Cascade Co2_nh3 Refrigeration
20/34
CO2
SystemsFactsOnEmissions
CO2CascadeSystemsreduceCO2emission
lb.less
CO2emission
for
each
kWh
saved
1mileinanaveragecarproducesonepound
ofCO2
emission
Cryogenicfreezingtypicallyuses2lbs.ofCO2
foreachpoundofproductfrozen
InaCO2cascadesystemstheCO2
iskept
insidetheclosedloop
20
-
7/25/2019 Cascade Co2_nh3 Refrigeration
21/34
CO2
SystemAdvantagesLowerFirstCost
LowerCosts
Compressors(LTside)
Suctionanddischargepiping,valvesinsulation,etc.
Liquidseparatorvessels(plusinsulation)
Refrigerant HigherCosts
Cascadeheatexchangerinsteadofintermediatecooler
vessel Liquidpiping,valvesinsulation,etc.
Higherpressureratingforsomecomponents
21
-
7/25/2019 Cascade Co2_nh3 Refrigeration
22/34
CO2
SystemAdvantagesLowerFirstCost
0.3
3.0
30
300
-67 -58 -49 -40 -31
Evaporating temperature (o
F)
Capacity(TR)
CO2
NH3
HighPressureCompressor
HPO28
StandardCompressor
CMO28
Condensing temperature at 14oF
22
-
7/25/2019 Cascade Co2_nh3 Refrigeration
23/34
CO2
SystemAdvantagesLowerFirstCost
Liquid, 300ft pipeLiquid, 300ft pipe
Pipe sizePipe size TemperatureTemperaturedropdrop
PressurePressuredropdrop
VelocityVelocity
InchInch FF PSIPSI ft / secft / sec
AmmoniaAmmonia 22"" 1.41.4 1.41.4 3.63.6
CO2CO2 4"4" 0.30.3 1.051.05 3.53.5
Discharge, 100ft pipeDischarge, 100ft pipe
Pipe sizePipe size TemperatureTemperaturedropdrop
PressurePressuredropdrop
VelocityVelocity
InchInch FF PSIPSI ft / secft / sec
AmmoniaAmmonia 6"6" 0.210.21 0.20.2 7979
CO2CO2 4"4" 0.140.14 0.90.9 2929
Wet suction, 300ft pipe, two 90 bends, one stop valveWet suction, 300ft pipe, two 90 bends, one stop valve
Pipe sizePipe size TemperatureTemperaturedropdrop
PressurePressuredropdrop
VelocityVelocity
InchInch FF PSIPSI ft / secft / sec
AmmoniaAmmonia 12"12" 1.011.01 0.310.31 5454
CO2CO2 6"6" 0.960.96 2.852.85 2323
Dry suction, 100ft pipe, two 90 bends, one stop valveDry suction, 100ft pipe, two 90 bends, one stop valve
Pipe sizePipe size TemperatureTemperaturedropdrop
PressurePressuredropdrop
VelocityVelocity
InchInch FF PSIPSI ft / secft / sec
AmmoniaAmmonia 12"12" 0.290.29 0.0890.089 6868
CO2CO2 6"6" 0.330.33 11 3939
Piping example 300TR at -40F
23
-
7/25/2019 Cascade Co2_nh3 Refrigeration
24/34
CO2
SystemAdvantagesCharge/Leaks
Lowammoniacharge
Ammonialimitedtoengineroom
CO2
doesnotdamageproducts
CO2
isnontoxicandnonflammable
However!!
Longtermexposurelimitis1%concentrationofCO2
Shorttermexposurelimitis3%concentrationofCO2
10 20%concentrationofCO2
ishealthandlife
threatening
CO2
detectors
are
required24
-
7/25/2019 Cascade Co2_nh3 Refrigeration
25/34
CO2
SystemAdvantages
Service/Maint. Norecoveryunitorwaterbasinsrequiredforopening
systemcomponent
Nosmell
NooildrainageonCO2
side
Alwayspositiveoperatingpressure
However!!
Becarefulwithtrappedliquid.Ifthetemperatureisincreasedby
7F,thepressureincreasestotheyieldlimitofsteelpipes!
Becareful
with
trapped
liquid/gas.
Saturated
liquid/gas
at
room
temperature e.g.68F=812 PSIG
Componentevacuationforair/moisturerequiredafterservice
25
-
7/25/2019 Cascade Co2_nh3 Refrigeration
26/34
CO2
SystemAdvantagesValveGroups
Penthouses,
piping and valvegroups on roof
26
-
7/25/2019 Cascade Co2_nh3 Refrigeration
27/34
CO2
SystemAdvantagesPiping
Condenserand
mainpiping
on
roof
27
-
7/25/2019 Cascade Co2_nh3 Refrigeration
28/34
CO2
RefrigerationSystems
CO2
Compressors
8cyl.206TR
4cyl.103TR
28
-
7/25/2019 Cascade Co2_nh3 Refrigeration
29/34
CO2
RefrigerationSystems
Ammonia
Compressors
Screw222TR
Screw
307
TR
Applications Typ. Cold Storage - Example
29
-
7/25/2019 Cascade Co2_nh3 Refrigeration
30/34
CO2
RefrigerationSystems
NH3
Surge
Acc.CascadeCO2Condenser
HPR&
LPR
Applications Typ. Cold Storage - Example
30
-
7/25/2019 Cascade Co2_nh3 Refrigeration
31/34
CO2
RefrigerationSystems
Economizer(CPR)
Glycolfloorwarming
heatedbyoilcoolers
CO2
HPR
(Highpressure
receiver)
Applications Typ. Cold Storage - Example
31
-
7/25/2019 Cascade Co2_nh3 Refrigeration
32/34
CO2
RefrigerationSystems
Oil Rectifier
Oil reservoir
Oil heater and
Temp. sensor
Oil return
Oil float switch
Applications Typ. Cold Storage - Example
32
-
7/25/2019 Cascade Co2_nh3 Refrigeration
33/34
CO2
RefrigerationSystems
Large PRWs utilizing Cascade
CO2
Refrigerating Systems
33
-
7/25/2019 Cascade Co2_nh3 Refrigeration
34/34
CCCCCCCCCCCCCCCCCCCCRRRRCCC
CCCCCCCCCCCCCCCCCCCLLLLCCCCCCCCCCCCCCCCCCCCCCCCCCCLLLLLL
LUCK
ThankYou
ChuckToogood
M&MRefrigeration,
Inc.
(410)7548005
34