cargo manual 61
TRANSCRIPT
-
8/14/2019 Cargo Manual 61
1/1
Issue: 1 4.3 Cargo Pumps Page 3 of 10
Start
Seq Start/StopSwitch = 'Start'
Operation Mode is
Selected
Own Cargo Pump
is Running
Another Pump in SameTank is Running
Another Pump in Same
Tank is Running
8 Step or 4 Step
8 Step or 4 Step
Another Cargo Pump
Start Function inSame Tank is Running
Seq Start/StopSwitch Stop
Seq Start/Stop
Switch Stop
Seq AbnormalStop Processing
Another Pump in SameTank is Running
8 Step or 4 Step
8 Step or 4 Step
Pump Stop
Seq Abnormal
Stop Processing
Full Open Filling Valve
Load Controller Mode : Auto
Activate Chime (10 sec)
Activate Chime (10 sec)
Run Pump
Wait (5 sec)
Wait (60 sec)
Stop Pump
Set Pre-Set Value of Cargo
Pump Discharge ValvePosition To Controller
Pre-Set Value of PumpLoad to Pump
Load Controller
Discharge valve PositionController Mode : CAS
Load Controller
Mode : Manual
Reduce Position
Discharge Valve
Full CloseDischarge Valve
Cargo Pump Start Function
is Completed
Discharge Start OperationFinish CheckFilling Valve Position < 2%
andLiquid Branch Valve Position > 50%
Stop Level > LO*2
Tank Level < LO*2+ 1*4
Tank Level 95%and
Liquid Branch Valve Position < 2%
Full
Open
Full
Close
LiquidBranch
Valve
Fill
Valve
Discharge Operation Start
Time (sec)
Time (sec)
FullOpen
FullClose
20 sec 40 sec
60 sec
Illustration 4.3.1b Unloading Flow Diagram
HEAVY INDUSTRIESShipping Co.,Ltd SK Supreme Cargo System Operating Manual