Contribute to fuel efficiency
Contribute to fuel efficiency
Japan TechnologyJapan Technology Basic TechnologyBasic Technology
2 Step Fluid Loss Prevention System2 Step Fluid Loss PreventionSystem New Technology 1New Technology 1
Silver AlloySilver Alloy
Adopt “Panasonic Original Expand Grid”
Adopt “Panasonic Original Calcium Alloy”
Technology 1Technology 1
Characteristic of “Casting Plate” Characteristic of “Expand Plate”
Panasonic can produce the “Strong Grid”.Panasonic can produce the “Light Weight Grid”.
LONG LIFE
LIGHT WEIGHT
Technology 1Technology 2
Adopt “Panasonic Unique Surface Layer” on the PlateTechnology 1Technology 3
Characteristic of “Calcium Alloy”
Panasonic Original“New Calcium Alloy”
The Expansion Picture of lattice section
after the corrosion examination.
LONG LIFE
Panasonic is adopting on the top of platewith “Unique Surface Layer” technology.
Panasonic is adopting “Panasonic Original
Special Alloy (SX2)” in normal calcium
alloy.
Panasonic can solve the MF's weak point
and maintain MF's good point.
• Good for “Anti Fluid Loss”• Good for “Long Stock”
<Merit>
<Demerit>• Weak for “High Temperature”• Weak for “Big Charge & Discharge”
Effect by Silver Alloy
Effect 1
LONG LIFE
Anti High Temperature Improvement
Effect 2
Gas Generated Prevention
LOW MAINTENANCE
MF Silver alloy is used for the battery plates. The result is extendedbattery life due to increasing of “Heat” endurance.
MF Silver alloy also helps to control electrolysis that occurs during recharging, as well as controlling internal leaking by reducing volume of gas generation.Panasonic coat the surface of grid by silver alloy.(Current Panasonic original Ca alloy + Silver Coating)
New Technology 2New Technology 2
Burst Prevention Vent PlugBurst Prevention Vent Plug New Technology 3New Technology 3
Panasonic install theoriginal vent plug whichhas “Special Filter”.This filter can preventfluid loss and releaseonly gas.
The water vapors from gas hole can be kept at the topposition by special sticker. Then, the water will be
circulated inside the battery.
Panasonic original "2 Step Fluid Loss Prevention System" controls the electrolysis and gas generation which are the factors of fluid level decrement. This technology is applied for goodof Maintenance Free Characteristic.
Tough MF for Commercial UseTough MF for Commercial Use New Technology 4New Technology 4
There are some possibilities to burst for car battery.
There are hydrogen gas in the car battery.Any car battery has possibility to burst byexternal spark.
Adopt “Burst Prevention Vent Plug” for All Panasonic MF BatteryPanasonic protect to burst from spark.
Panasonic adopt “Burst Prevention Vent Plug” for all MF battery.This vent plug protects the battery from rupturing due to externalsparks penetrating to the battery through the vent plug openingand igniting hydrogen gas.
Panasonic prepare handling manual for all modelsEven though we applied "Burst Prevention Vent Plug" for all MF Battery but we couldn't remove all explosion factor due to its static electricity. Therefore, Panasonic will input the "Handling Manual" which is written by 9 languages for all models.Please follow this handling manual before use the battery.
Panasonic success to develop the new battery which has both MF’s good point and CV’s good point.Panasonic started for D26 & D31 sizes which are major of commercial use.
1. Developing New Active Material(Strengthen for Charge & Discharge)
2. Install the Special Separator(Strengthen for Charge & Discharge)
Panasonic develop the new technology for “Heavy Duty”
High Reliability : Japan TechnologyHigh Reliability : Japan TechnologyTechnology used for Panasonic Car Battery
RESERVECAPACITY
(min)
MODEL
PANASONICMODEL
OLD JIS
VOLTCAPACITY
20HRS.(Ah)
SPECIFICATIONCCA VALUE
IEC JIS
NOMINALCCA VALUE
JIS
RESERVECAPACITY
(min)
MAXIMUM DIMENSION (mm)WEIGHT
WITH ACID(kg)L W H TH
TOUGH MF
NX100-5
NX100-5L
N-85D26R-CB
N-85D26L-CB
N-115D31R-CB
N115D31L-CB
12
12
12
12
70
70
90
90
319
319
426
426
490
490
655
655
570
570
695
695
103
103
132
132
260
260
306
306
173
173
173
173
204
204
204
204
225
225
225
225
17.7
17.7
21.7
21.7
Recommended Car Type For MF HIGH SPECLuxury CarsPassenger CarsPassenger Cars
Remark : Packing Standard 1 pc/carton
Panasonic Car Battery with New HEAD2 AlloyImproving Plate Durability for Longer Life in high temperature usage.
HEAD2 Alloy
Normal Part
Corrosion
Normal Part
Corrosion
New
Cal
cium
Allo
y(H
EAD
2)N
orm
al C
alci
um A
lloy
Alloy Combination Rate
Dow
nD
urab
ility
Up
Test Combination
PLUS ! Silver Alloy CoatingExtend battery life by increased Heat Endurance & control electrolyte vapourization from gas generated.
Current OriginalCalcium Alloy Grid
Coating bySilver Alloy
Panasonic OriginalSilver Alloy
Silver Coating
Cross Sectionof Grid
The Image of GridCross Section
RC : Reserve Capacity by discharge 25A from 12.0V to 10.5V, 25˚C (Reference average value)CCA : Cold Cranking Amps at 0˚F (-18˚C) JIS Measurement Year 2016 (Reference average value)
We use same basic technology as Japan factorywhich technology is trusted by car maker.
Panasonic use the “Burst Prevention Vent Plug”for all MF Battery. We can preventburst from external spark.
Panasonic can control to fluid loss due tothe “Special Filter” and “Special Sticker”as possible as we can.
Panasonic develop Silver Alloy technologyto strengthen battery for high temperature.
Technologies used for Panasonic Car Battery
CAPACITY
20HRS.
(Ah)
MODELVOLT
AVAILABLE
TERMINAL
TYPE L W H TH
MAXIMUM DIMENSION (mm) WEIGHT
WITH
ACID (kg)OLD JISPANASONIC
MODELEN TYPE
NOMINAL
CCA VALUE
JIS
RESERVE
CAPACITY
(min)
SPECIFICATION
CCA VALUE
IEC JIS
NS60L / NS60
NS60LS / NS60S
NX100-S6L / NX100-S6
NX100-S6LS / NX100-S6S
N50ZL / N50Z
NS70L / NS70
NX110-5L / NX110-5
N70ZL / N70Z
NX120-7L / NX120-7
Bottom Hold Down (BHD)
DIN43
DIN44
DIN55R / DIN55
DIN60
DIN62
DIN66
DIN71
DIN74
DIN88
DIN100
N-34B19-FH
N-38B19-FH
N-44B19-FH
N-46B24-FH
N-46B24-FH
N-55B24-FH
N-55B24-FH
N-65B24-FH
N-70D23-FH
N-80D23-FH
N-55D26-FH
N-75D26-FH
N-85D26-FH
N-90D31-FH
N-100D31-FH
N-115D31-FH
N-38B19-BA
N-44B19-BA
N-80D23-BA
N-85D26-BA
N-115D31-BA
N-544L21L
N-544H21L
N-555H25
N-560L25
N-562H25
N-566H28L
N-571L28
N-574H28
N-58815
N-60038
N-LN4-PA
LBN1
LN1
LN2
LBN2
LN2
LN3
LBN3
LN3
LN5
LN5
LN4
L / R
L / R
L / R
L / R
LS / RS
L / R
LS / RS
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
32
35
40
45
45
45
45
52
60
65
60
65
70
70
80
90
35
40
65
70
90
50
50
55
60
62
66
71
74
88
100
80
156
172
225
192
192
241
241
315
208
302
189
241
319
247
367
426
172
225
302
319
426
234
234
241
241
296
293
309
332
358
393
447
240
265
300
295
295
370
370
420
320
465
290
370
490
380
565
655
265
300
465
490
655
360
360
370
370
455
450
475
510
550
605
698
261
301
350
364
364
408
408
439
438
522
377
530
547
570
646
728
301
350
522
547
728
370
378
436
460
480
475
500
540
670
733
710
38
43
51
56
56
64
64
79
74
95
82
89
103
116
125
132
43
51
95
103
132
70
70
90
90
90
110
110
110
150
165
140
187
187
187
238
238
238
238
238
232
232
260
260
260
306
306
306
187
187
232
260
306
210
210
245
245
245
275
275
275
355
355
314
127
127
127
129
129
129
129
129
173
173
173
173
173
173
173
173
135
135
173
173
173
175
175
175
175
175
175
175
175
175
175
175
203
203
203
203
203
203
203
203
204
204
204
204
204
204
204
204
203
203
204
204
204
175
190
190
175
190
190
175
190
190
190
190
227
227
227
227
227
227
227
227
225
225
225
225
225
225
225
225
227
227
225
225
225
175
190
190
175
190
190
175
190
190
190
190
8.5
9.0
9.5
11.3
11.3
12.1
12.1
12.7
14.4
15.6
15.2
16.4
17.3
18.8
20.0
21.7
9.0
9.5
15.6
17.3
21.7
12.2
12.5
13.5
14.1
14.4
15.7
16.9
16.9
21.8
23.0
21.2
Maintenance Free (High Spec)
Power that you can rely on
Power that you can rely on
NS60L / NS60
NS60LS / NS60S
NX100-S6L / NX100-S6
NX100-S6LS / NX100-S6S
N50ZL / N50Z
NS70L / NS70
NX110-5L / NX110-5
N70ZL / N70Z
NX120-7L / NX120-7
Bottom Hold Down
(BHD)
N-34B19-FS
N-38B19-FS
N-46B24-FS
N-46B24-FS
N-55B24-FS
N-55B24-FS
N-70D23-FS
N-80D23-FS
N-55D26-FS
N-75D26-FS
N-85D26-FS
N-90D31-FS
N-100D31-FS
N-115D31-FS
N-38B19-BB
N-70D23-BB
N-80D23-BB
N-85D26-BB
N-100D31-BB
N-115D31-BB
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
L / R
L / R
L / R
LS / RS
L / R
LS / RS
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
L / R
32
35
45
45
45
45
60
65
60
65
70
70
80
90
35
60
65
70
80
90
156
172
192
192
241
241
208
302
189
241
319
247
367
426
172
208
302
319
367
426
240
265
295
295
370
370
320
465
290
370
490
380
565
655
265
320
465
490
565
655
261
301
364
364
408
408
438
522
377
530
547
570
646
728
301
438
522
547
646
728
38
43
56
56
64
64
74
95
82
89
103
116
125
132
43
74
95
103
125
132
187
187
238
238
238
238
232
232
260
260
260
306
306
306
187
232
232
260
306
306
127
127
129
129
129
129
173
173
173
173
173
173
173
173
135
173
173
173
173
173
203
203
203
203
203
203
204
204
204
204
204
204
204
204
203
204
204
204
204
204
227
227
227
227
227
227
225
225
225
225
225
225
225
225
227
225
225
225
225
225
8.5
9.0
11.3
11.3
12.1
12.1
14.4
15.6
15.2
16.4
17.3
18.8
20.0
21.7
9.0
14.4
15.6
17.3
20.0
21.7
AVAILABLETERMINAL
TYPE
MODEL SPECIFICATIONCCA VALUE
OLD JIS
MAXIMUM DIMENSION (mm)
L W H THPANASONICMODEL IEC JIS
VOLTCAPACITY
20HRS.(Ah)
NOMINALCCA VALUE
JIS
RESERVECAPACITY
(min)
WEIGHTWITH ACID
(kg)
Maintenance Free (Standard)
MODEL
PANASONIC MODELOLD JISVOLT
CAPA.
20HRS.
(Ah)
NOMINAL
CCA VALUE
IEC JIS
RESERVE
CAPACITY
(min)
MAXIMUM DIMENSION (mm)
L W H TH
WEIGHT
WITHOUT
ACID (kg)
APPROX.
ACID PER
BATTERY
(L)
ASSEMBLY
FIGURE
CONTAINER
MATERIAL
NORMAL
CHARGING
RATE
AMP.