built-in panel mounting kit
TRANSCRIPT
INSTALLATION GUIDE
Built-In Panel Mounting Kit
Contents
Built-In Panel Mounting Kit 3
Mounting Instructions 4
Model BI-36R / BI-36F 5
Model BI-30U 6
Model BI-36U 7
Model BI-36UFD 8
Model BI-42UFD 9
Model BI-36S 10
Model BI-42S / BI-42SID / BI-42SD 11
Model BI-48S / BI-48SID / BI-48SD 12
Model BI-36R / BI-36F—Dual Installation 13
Model BI-30U—Dual Installation 15
Model BI-36U—Dual Installation 17
Built-In Panel Mounting Kit 2
Features and specifications are subject to change at any time without notice. Visit subzero.com/specs for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
Built-In Panel Mounting Kit 3
subzero.com/specs
Built-In Panel Mounting Kit
OVERLAY AND FLUSH INSET PANELS
The panel mounting kit consists of stock lengths of PVC cleats, self-drilling mounting screws and offset gages for correctly locating the mounting cleats on the back of decorative panels (overlay and flush inset). Each Sub-Zero built-in model has a page in this guide which provides the cut length of each cleat and offset required for mounting. This kit works for all built-in models except glass door models (no kit available). Dual installations require two mounting kits for sufficient cleat stock and screws.
Be sure decorative panels have sufficient thickness where screws will be installed. If not, use the alternate hole pattern in the cleat or locate a new pattern. Use the longer 3/4" (19) screws wherever possible, especially along the bottom of panels and next to a custom handle, where most of the load will be.
When panel construction permits, use the existing hole pattern closest to the outer edge of the cleat. Screws can be driven through the cleat where there are no clearance holes. This is recommended near the door handle and on the bottom cleat of decorative panels greater than 3/4" (19) thick, to support the extra weight.
PANEL MOUNTING KIT CONTENTS:
• (8) 65" (1651) lengths of PVC cleat stock.
• (50) #8 x 5/8" zip-in screws.
• (50) #8 x 3/4" zip-in screws.
• Set of two offset gages (two offsets per gage).
• Installation guide.
Mounting Instructions 4
Mounting Instructions
1) Determine location and mounting method of custom door handle if one will be used. Decide the best way to modify the cleat for the handle if necessary (cut cleat completely or notch to fit). Also, determine the best sequence for installing handle and cleat. Panel will need to overhang the work surface if handle is installed before cleating.
2) Provide surface protection and lay decorative panel on a flat work surface with finished side down.
3) Locate the page of these instructions that applies to your specific built-in model and installation (single or dual). Circle the panel illustration for your application (overlay or flush inset) for better reference as you proceed.
4) Check dimensions of the decorative panels against the panel illustration to be sure they are exactly the right size.
5) Cut mounting cleats to length according to the chart. Measure and cut longest cleats first. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Use a general purpose blade in any type of carpentry saw.
6) Using the offset gages provided, reference the panel illustration to arrange cleats on the panel. Keep in mind that you are working on the back side of the panel. Horizontal cleats should extend to the outside of vertical cleats for maximum screw count.
7) Double check cleat offset locations. Attach cleats initially with screws in the slotted holes of the cleats. Using quick clamps helps with accurate cleat place-ment while driving screws. Start on one end of the cleat and work along the length as you install screws. This makes it easier to maintain the proper offset if there is any bow in the cleat.
OFFSET GAGE
BACK SIDEOF PANEL
HORIZONTALCLEAT
Offset gage.
Panel mounting.
DOOR TRIM
DOOR
PANEL
HORIZONTALCLEAT
8) Install panel assemblies on door(s) and grille of the built-in unit. Refer to the built-in refrigeration instal-lation guide for this procedure. Note any fine adjust-ments needed. Remove panel assemblies from the unit and adjust cleats as required for proper panel alignment. Attach remainder of screws in round holes. Add extra screws in the bottom cleat if panel is thicker than 3/4" (19).
9) If there is flex in the center of the panel, install short pieces of leftover cleat stock to the back of the panel to maintain spacing from the unit door.
10) Reinstall panel assemblies and replace door trim.
Make sure the built-in unit is secured in place with anti-tip brackets to prevent tipover when panel weight is added to open doors.
subzero.com/specs
Model BI-36R / BI-36F 5
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL
36" (914)
91/4"(235)
693/4"(1772)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3) 1/8" (3)
OVERLAY PANELS
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL91/4"(235)
693/4"(1772)
37" (940)
5/8" (16) 5/8" (16)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Door 35" (889) 65" (1651)*
*No cut required.
Model BI-36R / BI-36F
SINGLE INSTALLATION
Mounting kit is not intended for use with glass door model. The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-30U 6
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE
30" (762)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3)
OVERLAY PANELS
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE
31" (787)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 29" (737) None Grille (88" finished height) 29" (737) 8" (203) Refrigerator 29" (737) 451/2" (1156) Freezer 29" (737) 14" (356)
Model BI-30U
SINGLE INSTALLATION
Mounting kit is not intended for use with glass door model. The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
subzero.com/specs
Model BI-36U 7
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL
36" (914)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3)
OVERLAY PANELS
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL
37" (940)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Refrigerator 35" (889) 451/2" (1156) Freezer 35" (889) 14" (356)
Model BI-36U
SINGLE INSTALLATION
Mounting kit is not intended for use with glass door model. The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36UFD 8
1/2"(13)
5/8"(16)
FREEZER PANEL(FRONT OF PANELS)
GRILLE PANEL
36" (914)
91/4"(235)
501/8"(1273)
19"(483)
REFRIGERA-TOR PANEL
REFRIGERA-TOR PANEL
177/8"(454)
177/8"(454)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3)
1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
5/8"(16)
FREEZER PANEL(FRONT OF PANELS)
GRILLE PANEL
37" (940)
91/4"(235)
501/8"(1273)
19"(483)
REFRIGERA-TOR PANEL
REFRIGERA-TOR PANEL
183/8"(467)
183/8"(467)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
5/8" (16) 5/8" (16)
1/8" (3)1/8" (3)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Refrigerator (2 panels) 17" (432) 451/2" (1156) Freezer 35" (889) 14" (356)
Model BI-36UFD
SINGLE INSTALLATION
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-42UFD 9
1/2"(13)
5/8"(16)
FREEZER PANEL(FRONT OF PANELS)
91/4"(235)
501/8"(1273)
19"(483)
REFRIGERATORPANEL
REFRIGERATORPANEL
207/8"(530)
207/8"(530)
1/4" (6)
42" (1067)
GRILLE PANEL
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3)
1/8" (3)1/8" (3)
5/32"(4)
5/32"(4)
OVERLAY PANELS
1/2"(13)
5/8"(16)
FREEZER PANEL(FRONT OF PANELS)
91/4"(235)
501/8"(1273)
19"(483)
REFRIGERATORPANEL
REFRIGERATORPANEL
213/8"(543)
213/8"(543)
1/4" (6)
43" (1092)
GRILLE PANEL
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/8" (16) 5/8" (16)
1/8" (3)1/8" (3)
5/32"(4)
5/32"(4)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 41" (1041) None Grille (88" finished height) 41" (1041) 8" (203) Refrigerator (2 panels) 20" (508) 451/2" (1156) Freezer 41" (1041) 14" (356)
Model BI-42UFD
SINGLE INSTALLATION
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36S 10
subzero.com/specs
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Refrigerator 19" (483) 65" (1651)* Freezer 15" (381) 65" (1651)*
*No cut required.
1/2"(13)
GRILLE PANEL
36" (914)
91/4"(235)
693/4"(1772)
201/16"(510)
1511/16"(398)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OFPANELS)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3) 1/8" (3)
1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
GRILLE PANEL
37" (940)
91/4"(235)
693/4"(1772)
209/16"(522)
163/16"(411)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OFPANELS)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/8" (16) 5/8" (16)
1/8" (3)1/8" (3)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Model BI-36S
SINGLE INSTALLATION
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-42S / BI-42SID / BI-42SD 11
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 41" (1041) None Grille (88" finished height) 41" (1041) 8" (203) Refrigerator 24" (610) 65" (1651)* Freezer 16" (406) 65" (1651)*
*No cut required.
1/2"(13)
42" (1067)
91/4"(235)
693/4"(1772)
251/16"(637)
1611/16"(424)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OF PANELS)
1/4" (6)
GRILLE PANEL5/32"
(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3) 1/8" (3)
1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
43" (1092)
91/4"(235)
693/4"(1772)
259/16"(649)
173/16"(437)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OF PANELS)
1/4" (6)
GRILLE PANEL5/32"
(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3)1/8" (3)
5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Model BI-42S / BI-42SID / BI-42SD
SINGLE INSTALLATION
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-48S / BI-48SID / BI-48SD 12
subzero.com/specs
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 47" (1194) None Grille (88" finished height) 47" (1194) 8" (203) Refrigerator 28" (711) 65" (1651)* Freezer 18" (457) 65" (1651)*
*No cut required.
1/2"(13)
48" (1219)
91/4"(235)
693/4"(1772)
283/4"(730)
19"(483)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OF PANELS)
1/4" (6)
GRILLE PANEL5/32"
(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3)1/8" (3)
1/8" (3) 1/8" (3)
OVERLAY PANELS
1/2"(13)
49" (1245)
91/4"(235)
693/4"(1772)
291/4"(743)
191/2"(495)
FREEZERPANEL
REFRIGERATORPANEL
(FRONT OF PANELS)
1/4" (6)
GRILLE PANEL5/32"
(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3)1/8" (3)
5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Model BI-48S / BI-48SID / BI-48SD
SINGLE INSTALLATION
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36R / BI-36F—Dual Installation 13
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL
1/4" (6)
36" (914)36" (914)
91/4"(235)
693/4"(1772)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
GRILLE PANEL
1/4" (6)
91/4"(235)
693/4"(1772)
361/2" (927) 361/2" (927)
5/8" (16) 1/8" (3) 5/8" (16)1/8" (3)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Door 35" (889) 65" (1651)*
*No cut required.
Model BI-36R / BI-36F—Dual Installation
SEPARATE GRILLES
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36R / BI-36F—Dual Installation 14
subzero.com/specs
GRILLE PANEL
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
REFRIGERATOR PANEL(FRONT OF PANELS)
91/4"(235)
693/4"(1772)
721/4" (1835)
36" (914) 36" (914)
1/4" (6)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
GRILLE PANEL
1/2"(13)
REFRIGERATOR PANEL(FRONT OF PANELS)
REFRIGERATOR PANEL(FRONT OF PANELS)
91/4"(235)
693/4"(1772)
5/8" (16) 1/8" (3) 5/8" (16)1/8" (3)
731/4" (1861)
361/2" (927) 361/2" (927)
1/4" (6)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
FLUSH INSET PANELS
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 711/2" (1816) None Grille (88" finished height) 711/2" (1816) 8" (203) Door 35" (889) 65" (1651)*
*No cut required.
Model BI-36R / BI-36F—Dual Installation
DUAL WIDE GRILLE
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Model BI-30U—Dual Installation 15
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE GRILLE
1/4" (6)
30" (762)30" (762)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE GRILLE
1/4" (6)
301/2" (775) 301/2" (775)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3)1/8" (3)5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 29" (737) None Grille (88" finished height) 29" (737) 8" (203) Refrigerator 29" (737) 451/2" (1156) Freezer 29" (737) 14" (356)
Model BI-30U—Dual Installation
SEPARATE GRILLES
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-30U—Dual Installation 16
subzero.com/specs
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
601/4" (1530)
30" (762) 30" (762)
91/4"(235)
501/8"(1273)
19"(483)
GRILLE PANEL
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
611/4" (1556)
301/2" (775) 301/2" (775)
91/4"(235)
501/8"(1273)
19"(483)
GRILLE PANEL
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3)1/8" (3)5/8" (16) 5/8" (16)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 591/2" (1511) None Grille (88" finished height) 591/2" (1511) 8" (203) Refrigerator 29" (737) 451/2" (1156) Freezer 29" (737) 14" (356)
Model BI-30U—Dual Installation
DUAL WIDE GRILLE
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36U—Dual Installation 17
subzero.com/specs
1/2"(13)
5/8"(16)
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL
1/4" (6)
36" (914)36" (914)
91/4"(235)
501/8"(1273)
19"(483)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
GRILLE PANEL91/4"(235)
501/8"(1273)
19"(483)
361/2" (927)361/2" (927)
1/2"(13)
5/8"(16)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
5/8" (16) 1/8" (3) 5/8" (16)1/8" (3)
FLUSH INSET PANELS
Model BI-36U—Dual Installation
SEPARATE GRILLES
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 35" (889) None Grille (88" finished height) 35" (889) 8" (203) Refrigerator 35" (889) 451/2" (1156) Freezer 35" (889) 14" (356)
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
Model BI-36U—Dual Installation 18
subzero.com/specs
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
91/4"(235)
501/8"(1273)
19"(483)
721/4" (1835)
1/2"(13)
5/8"(16)
GRILLE PANEL
36" (914) 36" (914)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
1/8" (3) 1/8" (3) 1/8" (3)1/8" (3)
OVERLAY PANELS
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
REFRIGERATOR PANEL(FRONT OF PANELS)
FREEZER PANEL
91/4"(235)
501/8"(1273)
19"(483)
731/4" (1861)
1/2"(13)
5/8"(16)
GRILLE PANEL
361/2" (927) 361/2" (927)
1/4" (6)
5/32"(4)
3/32"(2)
3/32"(2)
5/32"(4)
5/32"(4)
5/32"(4)
5/8" (16) 1/8" (3) 5/8" (16)1/8" (3)
FLUSH INSET PANELS
Flush inset panel dimensions and mounting cleat offsets.
Overlay panel dimensions and mounting cleat offsets.
Cleat Cut Length
PANEL HORIZONTAL VERTICAL
Grille (83" or 84" finished height) 711/2" (1816) None Grille (88" finished height) 711/2" (1816) 8" (203) Refrigerator 35" (889) 451/2" (1156) Freezer 35" (889) 14" (356)
Model BI-36U—Dual Installation
DUAL WIDE GRILLE
The illustrations below provide panel dimensions and mounting cleat offsets for overlay and flush inset panels. Check dimensions of actual panels against the illustration for your panel application.
IMPORTANT NOTE: Panels are viewed from the front to show finished elevation. Cleats will be attached to the back of the panels.
Grille panel dimensions shown are for standard 84" (2134) nominal finished height of unit. Grille panel will be 1" (25)
shorter for 83" (2108) finished height and 4" (102) taller for 88" (2235) finished height.
Cut mounting cleats to length according to the chart. Cut lengths will be the same for overlay and flush inset panels. Horizontal cleats for panel bottoms should be cut to include as many holes as possible. Refer to page 4 for mounting instructions. Dual installations require two mounting kits.
Mounting cleat offset detail.
OFFSET GAGE
CLEAT
PANEL
OFFSET(OFFSET PROVIDED INPANEL ILLUSTRATION)
SUB-ZERO, INC. P. O. BOX 44848 MADISON, WI 53744 SUBZERO.COM 800.222.7820
7028798 REV-A 6/2013