buildings 4, 5 & 6 specifications · site specifications • net site area ±10.1 acres...

2
SITE SPECIFICATIONS Net Site Area ±10.1 Acres (±439,956 SF) BUILDING DIMENSIONS 3 Three-Story Buildings Building 4: 104,600 RSF Building 5: 106,250 RSF Building 6: 121,100 RSF Buildings 4 & 5 Dimensions: 250’-0” X 140’-0” Floor Plate: ±35,000 SF Building 6 Dimensions: 270’-0” X 150’-0” Floor Plate: ±40,000 SF Amenity Building B: 23,584 RSF FLOOR HEIGHTS First Floor: 16’-0” Second Floor: 14’-6” Top Floor to Roof: Varies; 14’-0” min. to 15’-9” Typical Tenant Finished Ceiling Height: 10’-0” BUILDING ENVELOPE 5’ wide X 14’-6” high Unitized Curtain Wall System with Duranar XL UC57638XL finish Viracon VRE30-38 Insulated Glazing Unit with 4.5” X 10” extruded aluminum profiles GROUND FLOOR ENTRY AREAS Starphire glazed balanced pivot doors with stainless steel hardware with panic device and closures MAIN LOBBY Build to suit by tenant Long Grain #4 Stainless Steel elevator doors and frames SUSTAINABILITY Targeting LEED® Gold Certification Level ELEVATORS Number of Cabs Per Building: Three (3) Type: Kone Monospace 700 Gearless Traction MRL Speed: 350 feet per minute HEATING, VENTILATION AND AIR CONDITIONING: Two (2) high efficiency, rooftop mounted packaged VAV AC units per building each sized for 50% of the design load Building 4: (2) units, 90-tons each Building 5: (2) units, 90-tons each Building 6: (2) units, 105-tons each Design cooling load shall be determined based on the following internal load calculation assumptions: 1.2 W/SF for lighting, 1.5 W/SF for office plug loads, and 100 SF/person occupant density in office spaces Outdoor condensing boiler plant consisting of two condensing boilers and two parallel, variable speed controlled, primary hot water pumps on the roof Building Management System by Automated Logic BUILDINGS 4, 5 & 6 SPECIFICATIONS

Upload: others

Post on 04-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BUILDINGS 4, 5 & 6 SPECIFICATIONS · SITE SPECIFICATIONS • Net Site Area ±10.1 Acres (±439,956 SF) BUILDING DIMENSIONS • 3 Three-Story Buildings • Building 4: 104,600 RSF

SITE SPECIFICATIONS• Net Site Area ±10.1 Acres (±439,956 SF)

BUILDING DIMENSIONS• 3 Three-Story Buildings

• Building 4: 104,600 RSF• Building 5: 106,250 RSF• Building 6: 121,100 RSF

• Buildings 4 & 5• Dimensions: 250’-0” X 140’-0”• Floor Plate: ±35,000 SF

• Building 6• Dimensions: 270’-0” X 150’-0”• Floor Plate: ±40,000 SF

• Amenity Building B: 23,584 RSF

FLOOR HEIGHTS• First Floor: 16’-0”• Second Floor: 14’-6”• Top Floor to Roof: Varies; 14’-0” min. to 15’-9”• Typical Tenant Finished Ceiling Height: 10’-0”

BUILDING ENVELOPE• 5’ wide X 14’-6” high Unitized Curtain Wall System

with Duranar XL UC57638XL finish• Viracon VRE30-38 Insulated Glazing Unit with

4.5” X 10” extruded aluminum profiles

GROUND FLOOR ENTRY AREAS• Starphire glazed balanced pivot doors with stainless

steel hardware with panic device and closures

MAIN LOBBY• Build to suit by tenant• Long Grain #4 Stainless Steel elevator doors

and frames

SUSTAINABILITY• Targeting LEED® Gold Certification Level

ELEVATORS• Number of Cabs Per Building: Three (3)• Type: Kone Monospace 700 Gearless Traction MRL• Speed: 350 feet per minute

HEATING, VENTILATION AND AIR CONDITIONING:

• Two (2) high efficiency, rooftop mounted packaged VAV AC units per building each sized for 50% of the design load• Building 4: (2) units, 90-tons each• Building 5: (2) units, 90-tons each• Building 6: (2) units, 105-tons each

• Design cooling load shall be determined based on the following internal load calculation assumptions: 1.2 W/SF for lighting, 1.5 W/SF for office plug loads, and 100 SF/person occupant density in office spaces

• Outdoor condensing boiler plant consisting of two condensing boilers and two parallel, variable speed controlled, primary hot water pumps on the roof

• Building Management System by Automated Logic

BUILDINGS 4, 5 & 6 SPECIFICATIONS

Page 2: BUILDINGS 4, 5 & 6 SPECIFICATIONS · SITE SPECIFICATIONS • Net Site Area ±10.1 Acres (±439,956 SF) BUILDING DIMENSIONS • 3 Three-Story Buildings • Building 4: 104,600 RSF

FOR LEASING INFORMATION CALL 408.330.0100 OR VISIT PATHLINEPARK.COM

FIRE PROTECTION• Automatic Fire Sprinkler Systems Shall be in accordance

with NFPA 13 and City Of Sunnyvale Fire Marshal

OUTDOOR PLAZA & BUILDING EDGES• Groves of redwoods will complement mature existing

redwoods to be preserved • A mix of regionally-relevant canopy and understory trees

will provide seasonal interest and shade• Bicycle lockers and bicycle racks on-site

ELECTRICAL SYSTEM• Electrical service via underground utility lines brought to

the site by PG&E • Underground conduit infrastructure shall extend to pad

mounted PG&E transformers located on-site adjacent to each building

• Buildings utilization voltage will be 277/480 volt, 3-phase, 4-wire with ampacity as required to accommodate square footages and loads

• Electrical service sizes of each office building are as follows:• Building 4: 2,000 amps• Building 5: 2,000 amps• Building 6: 2,500 amps

PARKING• Total Parking Spaces: 1,100 Spaces• Parking Ratio: 3.3/1,000• 33 Dual-Charge Electric Vehicle Charging Stations

(Expandable)• 6-Level Parking Garage

TELECOMMUNICATION SYSTEM• Service entrance from the telecommunication companies

shall consist of four (4) 4” underground conduits, one from AT&T, one from Comcast, one combined for other service provider’s and one spare

• Telecommunication rooms shall be provided stacked on each of the upper floors of the building, level 2 and up, with 4” conduit sleeves through the floor to interconnect with each other

PROJECT TEAM• Developer: Irvine Company• Design Architect: Arquitectonica• Executive Architect: LPA, Inc.• Landscape Architect: OJB• General Contractor: Devcon

©2019 The Irvine Company LLC. All rights reserved. All properties are offered for lease through Irvine Management Company, a licensed real estate broker DRE LIC. #02041810. The information in these materials has been obtained from various sources. LEED® —an acronym for Leadership in Energy and Environmental Design™—is a registered trademark of the U.S. Green Building Council®. While we believe the information to be reliable, neither the Irvine Company nor Irvine Management Company makes any representation or warranty as to the accuracy or completeness of such data and it should be independently verified by prospective tenants. The Irvine Company® and Pathline Park™ are registered trademarks of Irvine Management Company. Artist’s renderings based on current development concepts are subject to change without notice and are sole property of The Irvine Company LLC.

BUILDINGS 4, 5 & 6 SPECIFICATIONS