Legislation U-Value W/m2K
Schemes ActWall Roof
External Cavity Party Ceiling Pitched Flat
England
New BuildNotional 2010 BRegs Part L1A 0.18 0.13
Limiting 0.30 0.20 0.20
Existing
New & replaced 2010 BRegs Part L1B 0.28 0.16 0.18
Retained 0.30 0.55 0.16 0.18
Retained treshold 0.70 0.35
Wales
New BuildNotional 2014 BRegs Part L1A 0.18 0.13
Limiting 0.21 0.20 0.15
Existing
New & replaced 2014 BRegs Part L1B 0.21 0.15
Conversion&Renovation 0.30 0.55 0.16 0.18
Retained treshold 0.70 0.35
Scotland
New Build
NotionalTechnical Hardbook Section 6
0.19 0.20 0.13
Limiting (average) 0.25 0.18
Limiting (individual) 0.70 0.35
Existing
Extensions (Wall>0.70, Roof>0.25)
Technical Hardbook Section 6
0.19 0.13 0.15
Extensions (Wall<0.70, Roof<0.25)
0.22 0.15 0.18
Conversions (average) 0.30 0.25
Individual elements 0.70 0.35
BUILDING REGULATIONS
Building Regulations
Good pratice guidance
Building Regulations require thermal element within a building envelope to meet certain U-values. The target U-value depends on type of element, use of building and whether it is a new or an existing construction.
England, Wales ans Scotland are now each responsible for their own Building Regulations and target U-values can therefore differ throughout the UK. The above table gives a summary of requirements for domestic buildings at time of printing (October 2014). If required this information can be confirmed with your local Building Control.
The solutions provided may require an independent vapour control layer or breather membrane product to reduce the risk of interstitial condensation. Where a vapour control layer is required, a product with a vapour resistance Z>1100MNs/g should be used. Both vapour control layer and breather membrane need to be continuous and all joints sealed with adequate tape, to avoid air infiltration. To allow moist air to disperse into the atmosphere, the void between breather membrane and outer covering needs adequate ventilation. Please also refer to the installation guidelines.
FOR FURTHER ADVICE FROM ACTIS PLEASE CALL THE TECHNICAL DEPARTMENT ON 01249 462 888.
TIMBER FRAME WALLS
HYBRIS as standalone
A 140mm deep timber frame stud wall is filled with 120mm HYBRIS. This solution achieves the U-Value of 0.27W/m2.K with a single insulation product.
300mm
0mm
120mmU-Value 0.27W/m²K
HYBRIS
PF19: Between 140mm studs: 120mm HYBRIS full fill
TIMBER FRAME WALLS
A 90mm deep timber frame stud wall is filled with HYBRIS, faced internally with HCONTROL-HYBRID, the vapour control layer, and externally with plywood sheathing and BOOST’R HYBRID, the vapour permeable membrane. A 50mm cavity separates the timber frame from the outer leaf, typically of brick.This solution achieves the required U-Value of 0.17W/m2.K using 90mm studs.
U-Value 0.17W/m²K
Combination of HYBRID products
PF22: Between 90mm studs: HCONTROL HYBRID + 45mm HYBRIS + BOOST’R HYBRID
HYBRIS 45mm0mm
300mm
HCONTROL HYBRID
BOOSTR HYBRID
PF23: Between 140mm studs: HCONTROL HYBRID + 90mm HYBRIS + BOOST’R HYBRID
U-Value 0.14W/m²K
HYBRIS 90mm0mm
300mm
HCONTROL HYBRID
BOOSTR HYBRID
PF24: Between 140mm studs: HCONTROL HYBRID + 105mm HYBRIS
PF39: Between 72mm studs: HCONTROL HYBRID
PF25: Between 72mm studs: HCONTROL HYBRID + BOOST’R HYBRID
U-Value 0.18W/m²K
U-Value 0.30W/m²K
U-Value 0.21W/m²K
HYBRIS 105mm0mm
300mm
HCONTROL HYBRID
HCONTROL HYBRID
HCONTROL HYBRID
BOOSTR HYBRID
TIMBER FRAME WALLS
PF26: Between 150mm studs: 120mm HYBRIS + BOOST’R HYBRID
PF45: Between 90mm studs: 45mm HYBRIS + HCONTROL HYBRID
PF46: Between 72mm studs: BOOST’R HYBRID + 50 foam board
U-Value 0.18W/m²K
U-Value 0.23W/m²K
HYBRIS
120mm0mm
300mm
BOOSTR HYBRID
BOOSTR HYBRID
TIMBER FRAME WALLS
U-Value 0.23W/m²K
HYBRIS 45mm0mm
300mm
HCONTROL HYBRID
Combination of hybrid products with other materials
SOLID WALLS
HCONTROL HYBRID as standalone
HCONTROL HYBRID insulation is installed on the internal side of a solid wall.
U-Value 0.30W/m²K
PF40: 2 x 38 x 38 battens HCONTROL HYBRID
HCONTROL HYBRID
PITCHED ROOFS
Combination of hybrid products
BOOST’R HYBRID is used as breather membrane, HYBRIS is filled between the rafters, HCONTROL-HYBRID is laid as vapour control layer. Internal finish is a standard plasterboard. This solution achieves the required U-Value of 0,18W/m2.K without losing space.
PF30: 600mm timber centers: HCONTROL HYBRID + 45mm HYBRIS + BOOST’R HYBRID
U-Value 0.18W/m²K
HYBRIS 45mm0mm
300mm
HCONTROL HYBRID
BOOSTR HYBRID
120mm0mm
300mm
PF43: : 600mm timber centers: HCONTROL HYBRID + 120mm HYBRIS + BOOST’R HYBRID
U-Value 0.13W/m²K
HYBRIS
HCONTROL HYBRID
BOOSTR HYBRID
PITCHED ROOFS
PF33: 600mm timber centers : 120mm HYBRIS + BOOST’R HYBRID
U-Value 0.18W/m²K
HYBRIS
120mm0mm
300mm
BOOSTR HYBRID
PF34: 600mm timber centers: HCONTROL HYBRID + 60mm foam board
U-Value 0.18W/m²K
HCONTROL HYBRID
PF31: 600mm timber centers: HCONTROL HYBRID + 90mm HYBRIS
U-Value 0.18W/m²K
HYBRIS 90mm0mm
300mm
HCONTROL HYBRID
PITCHED ROOFS
U-Value 0.18W/m²K
BOOSTR HYBRID
PF42: 600mm timber centers: BOOST’R HYBRID + 85mm foam board
PF35 : 400mm timber centers: HCONTROL HYBRID + 70mm foam board
U-Value 0.18W/m²K
HCONTROL HYBRID
LOFT INSULATION
Between and over joists
HYBRIS is installed between and over ceiling joists or on continuous solid floors. This solution achieves the required U-Value of 0.16W/m2.K with a single product in 2 layers.
300mm
300mm
0mm
0mm
195mm
240mm
U-Value 0.16W/m²K
U-Value 0.13W/m²K
HYBRIS
HYBRIS
PF37: 600mm timber centers 90mm HYBRIS + 105mm HYBRIS
PF44: 600mm timber centers 90mm HYBRIS + 150mm HYBRIS