53-1004112-0122 April 2016
Brocade Fabric OSCommand Reference
Supporting Fabric OS 8.0.1
-
2016 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, Brocade Assurance, the B-wing symbol, ClearLink, DCX, Fabric OS, HyperEdge, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, Vplane, and Vyatta are registered trademarks, and Fabric Vision is a trademark of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of others.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, IncorporatedCorporate and Latin American HeadquartersBrocade Communications Systems, Inc.130 Holger WaySan Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: [email protected]
Asia-Pacific HeadquartersBrocade Communications Systems China HK, Ltd.No. 1 Guanghua RoadChao Yang DistrictUnits 2718 and 2818Beijing 100020, ChinaTel: +8610 6588 8888Fax: +8610 6588 9999E-mail: [email protected]
European HeadquartersBrocade Communications Switzerland SrlCentre SwissairTour B - 4me tage29, Route de l'AroportCase Postale 105CH-1215 Genve 15Switzerland Tel: +41 22 799 5640Fax: +41 22 799 5641E-mail: [email protected]
Asia-Pacific HeadquartersBrocade Communications Systems Co., Ltd. (Shenzhen WFOE)Citic PlazaNo. 233 Tian He Road NorthUnit 1308 13th FloorGuangzhou, ChinaTel: +8620 3891 2000Fax: +8620 3891 2111E-mail: [email protected]
Document History
Document title Publication number Summary of changes Publication date
Brocade Fabric OS Command Reference
53-1004112-01 Added 4 new commands.Modified 71 commands to support Fabric OS v8.0.1 features. Removed 13 commands. Updated Preface, surrounding chapters, and permission tables.
April 2016
-
Contents
Preface
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviiCommand syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Brocade resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Contacting Brocade Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Brocade customers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Brocade OEM customers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xx
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Brocade Gen 5 platform (16-Gbps) fixed-port switches . . . . . . . . . . . . . xxi
Brocade Gen 5 platform (16-Gbps) DCX Directors . . . . . . . . . . . . . . . . .xxii
Brocade Gen 6 platform (32-Gbps) fixed-port switches . . . . . . . . . . . . .xxii
Brocade Gen 6 platform (32-Gbps) Directors. . . . . . . . . . . . . . . . . . . . .xxii
What is new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxii
New commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiiModified commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxii
Deprecated commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxvCLI usage conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxvi
Chapter 1 Using Fabric OS Commands
Using the command line interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Understanding Role-Based Access Control. . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Understanding Virtual Fabric restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Determining RBAC permissions for a specific command. . . . . . . . . . . . . . . . . 3
Chapter 2 Fabric OS Commands
aaaConfig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Brocade Fabric OS Command Reference iii53-1004112-01
-
ag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
agAutoMapBalance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
agShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
aliAdd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
aliCreate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
aliDelete. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
aliRemove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
aliShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
appLoginHistory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
aptPolicy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
auditCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
auditDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
authUtil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
bannerSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
bannerShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
bcastShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
bladeCfgGeMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
bladeDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
bladeEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
bladeSwap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
bootLunCfg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
bufOpMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
cfgActvShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
cfgAdd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
cfgClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
cfgCreate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
cfgDelete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
cfgDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
cfgEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
cfgRemove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
cfgSave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
cfgShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
cfgSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
cfgTransAbort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
cfgTransShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
chassisBeacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
chassisCfgPerrThreshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
iv Brocade Fabric OS Command Reference53-1004112-01
-
chassisDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
chassisDistribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
chassisEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
chassisName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
chassisShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
classConfig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
cliHistory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
configDefault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
configDownload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
configList . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
configRemove. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
configShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
configUpload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
configureChassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
creditRecovMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
dataTypeShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
dbgShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
defZone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
diagClearError . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
diagDisablePost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
diagEnablePost. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
diagHelp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
diagPost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
diagRetry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
diagShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
diagStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
distribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
dlsReset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
dlsSet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
dlsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
dnsConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
enclosureShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
errClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
errDelimiterSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
errDump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Brocade Fabric OS Command Reference v53-1004112-01
-
errFilterSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
errModuleShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
errShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
ethIf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
exit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
extnCfg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
fabRetryShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
fabRetryStats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
fabricLog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
fabricName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
fabricPrincipal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
fabricShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
fabStatsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
fanDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
fanEnable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
fanShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
faPwwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
fastBoot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
fcipHelp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
fcipLedTest. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
fcipPathTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
fcPing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
fcpLogClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
fcpLogDisable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
fcpLogEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
fcpLogShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
fcpProbeShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
fcpRlsProbe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
fcpRlsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
fcrBcastConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
fcrConfigure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
fcrEdgeShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
fcrFabricShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
fcrIclPathBWMonitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
fcrLsan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
fcrLsanCount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
fcrLsanMatrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
vi Brocade Fabric OS Command Reference53-1004112-01
-
fcrPhyDevShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
fcrProxyConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
fcrProxyDevShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
fcrResourceShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
fcrRouterPortCost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
fcrRouteShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
fcrXlateConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
fddCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
fdmiCacheShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
fdmiShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
femDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
ficonCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
ficonClear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
ficonCupSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
ficonCupShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
ficonHelp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
ficonShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
fipsCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
firmwareActivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
firmwareCheck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
firmwareCleanInstall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
firmwareCommit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
firmwareDownload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
firmwareDownloadStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
firmwareKeyShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
firmwareRestore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
firmwareShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
firmwareSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
fosConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
fosExec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
frameLog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
fspfShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
gePortErrShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
haDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
haDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
Brocade Fabric OS Command Reference vii53-1004112-01
-
haEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
haFailover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
haReboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
haRedundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
haShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
haSyncStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
haSyncStop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371
historyLastShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
historyMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
historyShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
iflShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
interfaceShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381
iodReset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
iodSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
iodShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
ipAddrSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
ipAddrShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
ipFilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
ipSecConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
islShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
itemList . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
killTelnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
ldapCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427
lfCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429
licenseAdd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
licenseIdShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
licensePort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
licenseRemove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438
licenseShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
licenseSlotCfg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
linkCost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445
logicalGroup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447
login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
logout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452
lsanZoneShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453
viii Brocade Fabric OS Command Reference53-1004112-01
-
lsCfg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
lsDbShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
mapsConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
mapsDb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
mapsHelp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476
mapsPolicy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 477
mapsRule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 481
mapsSam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
memShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495
motd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496
msCapabilityShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 497
msConfigure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498
msPlatShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
msPlatShowDBCB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
msPlClearDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502
msPlMgmtActivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503
msPlMgmtDeactivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
msTdDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
msTdEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506
msTdReadConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
myId . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
nbrStateShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 509
nbrStatsClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 511
nodeFind . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513
nsAliasShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515
nsAllShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
nsCamShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 520
nsDevLog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523
nsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525
nsZoneMember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530
nsZoneShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534
openSource . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536
passwd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537
passwdCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540
pathInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
pdShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554
portAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 555
Brocade Fabric OS Command Reference ix53-1004112-01
-
portAlpaShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558
portBeacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559
portBufferCalc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561
portBufferShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563
portCamShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 566
portCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568
portCfgAlpa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598
portCfgAutoDisable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599
portCfgCompress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
portCfgCreditRecovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
portCfgDefault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606
portCfgDPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607
portCfgEncrypt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610
portCfgEport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612
portCfgEportCredits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614
portCfgEXPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
portCfgFaultDelay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
portCfgFec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623
portCfgFillword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629
portCfgFlogiLogout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631
portCfgFportBuffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632
portCfgGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633
portCfgGeMediaType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 636
portCfgGport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638
portCfgISLMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639
portCfgLongDistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 641
portCfgLossTov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645
portCfgLport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647
portCfgNonDfe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649
portCfgNPIVPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651
portCfgNPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 655
portCfgOctetSpeedCombo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 656
portCfgPersistence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 658
portCfgPersistentDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 660
portCfgPersistentEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663
portCfgQoS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666
portCfgShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 669
x Brocade Fabric OS Command Reference53-1004112-01
-
portCfgSpeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 682
portCfgTdz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685
portCfgTrunkPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687
portCfgVEXPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
portChannelShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691
portCmd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 693
portDebug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704
portDecom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705
portDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706
portDPortTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708
portEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717
portEncCompShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719
portErrShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
portFlagsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724
portLedTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726
portLogClear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 728
portLogConfigShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729
portLogDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730
portLogDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
portLogDumpPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732
portLogEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
portLogEventShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734
portLoginShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735
portLogPdisc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737
portLogReset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738
portLogResize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
portLogShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740
portLogShowPort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747
portLogTypeDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748
portLogTypeEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749
portLoopbackTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
portName. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754
portPeerBeacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757
portPerfShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759
portRouteShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 763
portShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765
portStats64Show . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 825
Brocade Fabric OS Command Reference xi53-1004112-01
-
portStatsClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 830
portStatsShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 832
portSwap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 840
portSwapDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 842
portSwapEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 843
portSwapShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 844
portTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845
portTestShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 848
portTrunkArea. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 851
portZoneShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 856
powerOffListSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 857
powerOffListShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 859
psShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 861
rasAdmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 862
rasMan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 865
reboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 867
relayConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 869
roleConfig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 871
rootAccess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874
routeHelp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
rtLogTrace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 876
sddQuarantine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 877
secActiveSize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 879
secAuthSecret . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 880
secCertUtil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 882
secCryptoCfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 893
secDefineSize. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 898
secGlobalShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 899
secHelp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901
secPolicyAbort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902
secPolicyActivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 903
secPolicyAdd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904
secPolicyCreate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907
secPolicyDelete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 911
secPolicyDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 913
secPolicyFCSMove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 916
secPolicyRemove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 918
xii Brocade Fabric OS Command Reference53-1004112-01
-
secPolicySave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 920
secPolicyShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 921
secStatsReset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 923
secStatsShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 925
sensorShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 927
serDesTuneMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 928
setContext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 931
setDbg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 932
setVerbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 933
sfpShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934
shellFlowControlDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 945
shellFlowControlEnable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 946
slotPowerOff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 947
slotPowerOn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 948
slotShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 949
snmpConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 954
snmpTraps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 967
spinFab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 970
sshUtil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 974
statsClear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 979
stopPortTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 980
supportFfdc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 981
supportFtp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 982
supportInfoClear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 984
supportSave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985
supportShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 989
supportShowCfgDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 992
supportShowCfgEnable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 994
supportShowCfgShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 996
switchBeacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 998
switchCfgPersistentDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
switchCfgPersistentEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1001
switchCfgSpeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1002
switchCfgTrunk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1003
switchDisable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1004
switchEnable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1005
switchName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1006
Brocade Fabric OS Command Reference xiii53-1004112-01
-
switchShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1008
switchUptime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024
switchViolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1025
syslogAdmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1026
sysShutDown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1028
tempShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1030
timeOut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1031
topologyShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1032
traceDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1036
trunkDebug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1038
trunkShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1039
tsClockServer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1043
tsTimeZone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1045
turboRamTest. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1049
upTime. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1050
uRouteShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1051
usbStorage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1053
userConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055
version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1061
wwn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062
wwnAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1064
wwnRecover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1066
zone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1068
zoneAdd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1080
zoneCreate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1082
zoneDelete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084
zoneHelp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1085
zoneObjectCopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1086
zoneObjectExpunge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1087
zoneObjectRename . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1089
zoneObjectReplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1090
zoneRemove. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1091
zoneShow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1093
Chapter 3 Primary FCS Commands
Primary FCS commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1099
xiv Brocade Fabric OS Command Reference53-1004112-01
-
Appendix A Command Availability
Command validation checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1101
Command Virtual Fabrics and Remote Domain execution restrictions. . . . 1102
Brocade Fabric OS Command Reference xv53-1004112-01
-
xvi Brocade Fabric OS Command Reference53-1004112-01
-
Preface
In this chapterDocument conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviiBrocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xixContacting Brocade Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xixDocument feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Document conventionsThe document conventions describe text formatting conventions, command syntax conventions, and important notice formats used in Brocade technical documentation.
Text formattingText formatting conventions such as boldface, italic, or Courier font may be used in the flow of the text to highlight specific words or phrases.
Format Description
bold text Identifies command names
Identifies keywords and operands
Identifies the names of user-manipulated GUI elements
Identifies text to enter at the GUI or CLI
italic text Identifies emphasis
Identifies variables
Identifies document titles
Courier font Identifies CLI output
Identifies command syntax examples
Command syntax conventionsBold and italic text identify command syntax components. Delimiters and operators define groupings of parameters and their logical relationships.
Brocade Fabric OS Command Reference xvii53-1004112-01
-
Notes, cautions, and warningsNotes, cautions, and warning statements may be used in this document. They are listed in the order of increasing severity of potential hazards.
NOTEA Note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information.
ATTENTIONAn Attention statement indicates a stronger note, for example, to alert you when traffic might be interrupted or the device might reboot.
CAUTIONA Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data.
DANGERA Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations.
Convention Description
bold text Identifies command names, keywords, and command options.
italic text Identifies a variable.
value In Fibre Channel products, a fixed value provided as input to a command option is printed in plain text, for example, --show WWN.
[ ] Syntax components displayed within square brackets are optional.
Default responses to system prompts are enclosed in square brackets.
{ x | y | z } A choice of required parameters is enclosed in curly brackets separated by vertical bars. You must select one of the options.
In Fibre Channel products, square brackets may be used instead for this pur-pose.
x | y A vertical bar separates mutually exclusive elements.
< > Nonprinting characters, for example, passwords, are enclosed in angle brackets.
... Repeat the previous element, for example, member[member...].
\ Indicates a soft line break in command examples. If a backslash separates two lines of a command input, enter the entire command at the prompt with-out the backslash.
xviii Brocade Fabric OS Command Reference53-1004112-01
-
Brocade resourcesVisit the Brocade website to locate related documentation for your product and additional Brocade resources.
You can download additional publications supporting your product at www.brocade.com. Select the Brocade Products tab to locate your product, then click the Brocade product name or image to open the individual product page. The user manuals are available in the resources module at the bottom of the page under the Documentation category.
To get up-to-the-minute information on Brocade products and resources, go to MyBrocade. You can register at no cost to obtain a user ID and password.
Release notes are available on MyBrocade under Product Downloads.
White papers, online demonstrations, and data sheets are available through the Brocade website.
Contacting Brocade Technical SupportAs a Brocade customer, you can contact Brocade Technical Support 24x7 online, by telephone, or by email. Brocade OEM customers contact their OEM/Solutions provider.
Brocade customersFor product support information and the latest information on contacting the Technical Assistance Center, go to http://www.brocade.com/services-support/index.html.
If you have purchased Brocade product support directly from Brocade, use one of the following methods to contact the Brocade Technical Assistance Center 24x7.
Brocade OEM customersIf you have purchased Brocade product support from a Brocade OEM/Solution Provider, contact your OEM/Solution Provider for all of your product support needs.
OEM/Solution Providers are trained and certified by Brocade to support Brocade products. Brocade provides backline support for issues that cannot be resolved by the OEM/Solution
Provider.
Online Telephone E-mail
Preferred method of con-tact for nonurgentissues: My Cases through
MyBrocade Software down-
loads and licensing tools
Knowledge Base
Required for Sev 1-Critical and Sev2-High issues: Continental US: 1-800-752-8061 Europe, Middle East, Africa, and Asia
Pacific: +800-AT FIBREE (+800 28 34 27 33)
For areas unable to access toll free num-ber: +1-408-333-6061
Toll-free numbers are available in many countries.
[email protected] include: Problem summary Serial number Installation details Environment description
Brocade Fabric OS Command Reference xix53-1004112-01
http://www.brocade.comhttp://my.brocade.comhttp://my.brocade.comhttp://www.brocade.com/products/index.pagehttp://www.brocade.com/services-support/index.htmlhttps://fedsso.brocade.com/sps/BrocadeIDPSF/saml20/logininitial?RequestBinding=HTTPPost&PartnerId=https://brocade.my.salesforce.comhttp://my.brocade.com/wps/myportal/!ut/p/b1/hY7NDoIwEIQfaXe7FdNjoWhoqBgThPZiejJNFC_G50eIV8scJ9_8QABPRCz3XDCMEKb4Sff4Tq8pPuC0OKG4lQd9ZclMnbUVNkdz6ZV1AssdDF_EZ5BWrg3OuIpqwYRno7Ahw1bXSiDiL49_pHErP0DInlwerEBm4ul9P2LSM-kStbY!/http://my.brocade.com/wps/myportal/!ut/p/b1/hY7NDoIwEIQfaXe7FdNjoWhoqBgThPZiejJNFC_G50eIV8scJ9_8QABPRCz3XDCMEKb4Sff4Tq8pPuC0OKG4lQd9ZclMnbUVNkdz6ZV1AssdDF_EZ5BWrg3OuIpqwYRno7Ahw1bXSiDiL49_pHErP0DInlwerEBm4ul9P2LSM-kStbY!/http://kb.brocade.com/kb/index?page=homehttp://www.brocade.com/services-support/international_telephone_numbers/index.page
-
Brocade Supplemental Support augments your existing OEM support contract, providing direct access to Brocade expertise. For more information, contact Brocade or your OEM.
For questions regarding service levels and response times, contact your OEM/Solution Provider.
Document feedbackTo send feedback and report errors in the documentation you can use the feedback form posted with the document or you can e-mail the documentation team.
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. You can provide feedback in two ways:
Through the online feedback form in the HTML documents posted on www.brocade.com. By sending your feedback to [email protected] the publication title, part number, and as much detail as possible, including the topic heading and page number if applicable, as well as your suggestions for improvement.
xx Brocade Fabric OS Command Reference53-1004112-01
www.brocade.com
-
About This Document
In this chapterSupported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiWhat is new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiiCLI usage conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxvi
Supported hardware and softwareIn those instances in which procedures or parts of procedures documented here apply to some devices but not to others, this list identifies exactly which devices are supported by Fabric OS 8.0.1 and which are not
Although many different software and hardware configurations are tested and supported by Brocade Communication Systems, Inc for Fabric OS 8.0.1, documenting all possible configurations and scenarios is beyond the scope of this document.
Fabric OS 8.0.1 provides features that interoperate with the Brocade Analytics Monitoring Platform running Fabric OS 7.4.0_amp. For more information about the Brocade Analytics Monitoring Platform and Fabric OS 8.0.1, you can find content on MyBrocade.com.
The following hardware platforms are supported by Fabric OS 8.0.1.
Brocade Gen 5 platform (16-Gbps) fixed-port switches Brocade 6505 switch Brocade 6510 switch Brocade 6520 switch Brocade M6505 blade server SAN I/O module Brocade 6543 blade server SAN I/O module Brocade 6545 blade server SAN I/O module Brocade 6546 blade server SAN I/O module Brocade 6547 blade server SAN I/O module Brocade 6548 blade server SAN I/O module Brocade 6558 blade server SAN I/O module Brocade 7840 Extension Switch
Brocade Fabric OS Command Reference xxi53-1004112-01
-
Brocade Gen 5 platform (16-Gbps) DCX Directors
NOTEFor ease of reference, Brocade chassis-based storage systems are standardizing on the term Director. The legacy term Backbone can be used interchangeably with the term Director.
Brocade DCX 8510-4 Director Brocade DCX 8510-8 Director
Brocade Gen 6 platform (32-Gbps) fixed-port switches Brocade G620
Brocade Gen 6 platform (32-Gbps) Directors Brocade X6-4 Director Brocade X6-8 Director
What is new in this documentThe Virtual Fabric restrictions for Fabric OS commands table in the Appendix A, Command Availability, has been updated. The table lists the Context, Switch type, and Remote Domain Execution for the commands.
NOTEAdmin Domain is deprecated and the information about Admin Domain restrictions are removed.
New commands diagStatus - Displays currently running diagnostic tests. haReboot - Performs high availability (HA) reboot. openSource - Displays open-source licenses. rootAccess - Configures root access through CLI.
Modified commands aaaConfig - Added a note that the -e operand is applicable only to RADIUS configuration. ad - The following error message is displayed when you execute this command:
Warning: Admin Domains are not supported in Fabric OS v8.0.1. Admin Domain commands and functionality will be removed in future Fabric OS versions.
authUtil - Added a note that before setting the authentication type using the -a operand, you must make sure that FCAP certificates and dhchap secrets are configured. The --authinit command does not initiate authentication on disabled ports.
xxii Brocade Fabric OS Command Reference53-1004112-01
-
bladeCfgGeMode - This command is supported only on the Brocade FX8-24 blade in a Brocade DCX 8510 chassis.
cfgSize - Removed all references to the term Admin Domain. chassisBeacon - Added a note that on a Brocade X6 Director, enabling chassis beaconing
activates beaconing on CP blades also.
chassisName - Added a note that the chassis name configured using this command appears in all the chassis event-related RASLog messages.
configDownload - Added the steps to perform to backup and then restore a configuration in a switch using Virtual Fabrics.
configUpload - Added the steps to perform to backup and then restore a configuration in a switch using Virtual Fabrics.
configure - Added F-Port Device Update Mode field. diagShow - Added a note that the -post operand is supported only on 32 Gbps-capable
platforms. distribute - Added a note that if FCS policy is enabled, only primary FCS switch can distribute
the data.
extnCfg - Added the --config -default and --config -clear operands. fanDisable - Added note that the fan units on a Brocade X6 Director do not change their RPM
speed to 0 and they take few minutes to change the speed to minimum RPM after being disabled.
faPwwn - Added a note that the ports must be disabled before executing the --enable and --assign options.
fcipLedTest - Added the behavior of this command on the Brocade SX6 extension blade. fcipPathTest - Added details for Brocade SX6 extension blade. fcrEdgeShow - This command displays information only for online EX_Ports. fddCfg - Added a note that when a policy is set to strict mode, the manual distribution of the
policy is not allowed.
firmwareDownload - Removed the following unsupported operands: -a, -t, -e, and -o. flow - Added the predefined frame type Srr. fosExec - Added a note that the --domain operand can be executed only if the remote Fosexec
feature is enabled on local and remote switches.
haShow - Added slot number details for the Brocade X6 Director. Added haShow command example on the Brocade X6 Director.
mapsConfig - Removed sw_critical and sw_marginal MAPS actions. These actions are always enabled by default.
mapsDb - Added new fields fenced circuits and ports with highest zoned device ratio fields. mapsRule - Added the following monitoring systems under the respective category
GE Port Health: GE_CRC, GE_INV_LEN, GE_LOS_OF_SIG, STATE_CHG, UTIL, and IP_UTIL. FCIP health: IP_UTIL, IP_PKTLOSS, IP_RTT, and IP_JITTER. Fabric performance impact: CRED_ZERO, THPUT_DEGRADE, and IT_FLOW. Security health: DAYS_TO_EXPIRE, EXPIRED_CERTS, DID_CHG, FLOGI, and FAB_CFG. Fabric state change: TEMP, ETH_MGMT_PORT_STATE, and FLASH_USAGE. Switch status policy: FAN_AIRFLOW_MISMATCH.
Brocade Fabric OS Command Reference xxiii53-1004112-01
-
msConfigure - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlClearDB - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlMgmtActivate - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msPlMgmtDeactivate - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msTdDisable - Removed the following note: This command is supported only in AD0 and AD255 contexts.
msTdEnable - Removed the following note: This command is supported only in AD0 and AD255 contexts.
nodeFind - The command is enhanced to accept WWN as single hexadecimal value. nsShow - Added the Device link speed field. passwdCfg - Added the -charset, -allowuser, --hash, and --showhash options. portCfg - Added details for Brocade SX6 blade and removed all references to Brocade 7800.
Added the following options: sla, --proto-app, --rst-propagation, --non-terminated, and --load-leveling. Removed the --legacy option.
portCfgCompress - Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported.
portCfgDefault - Added the --help option. portCfgEncrypt - Added the following note: On 16 Gbps-capable platforms, both encryption and
compression features are supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported.
portCfgEportCredits - Modified the description of the credits option. Modified the description to state that E_Port credits are mutually exclusive with Buffer Optimized mode. ICL ports are supported with this command. Added valid credit range for ICL ports.
portCfgGE - Added details for Brocade SX6 blade and removed Brocade 7800. portCfgNonDfe - Updated the description and the --show ouput. Added new 8G Non-DFE State
field.
portCfgQoS - The --setratelimit operand is not supported on Brocade X6-4 Director and Brocade X6-8 Director.
portCfgShow - Added details for Brocade SX6 blades and removed all references to Brocade 7800. Added the following options: lag, tcl, and sla.
portCfgSpeed - Added 32 Gbps fixed speed. Added a note that speed ax is not supported on 16G and 32G platforms and s is not supported on 32G platforms.
portCmd - Added support for Brocade SX6 extension blade. Added the following options: --uni-directional, --dscp, --l2cos, -summary, -connection, -detail, -historical, and --all-ls.
portDPortTest - Added --set [ewrap | owrap] and --clear [ewrap | owrap] options. Added the following note: The D_Port long duration test can only be run on a single port at a time.
portEncCompShow - Removed the Active Speed field from the output. Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported.
xxiv Brocade Fabric OS Command Reference53-1004112-01
-
portLedTest - Removed the ceeportledtest command. portLoopbackTest - Removed the ceeportloopbacktest command. portName - Added -d option. portShow - Added details for Brocade SX6 blade and removed Brocade 7800. Added the following
options: sla, --link-local, --sort, -reset, -lifetime, --hist-stats, and --filter.
portStats64Show - The stat64_fec_cor field is displayed only on 16 Gbps-capable platforms and not on 32 Gbps-capable platform.
portStatsShow - Added fec_corrected_rate field. The fec_cor_detected and tim_latency_vc fields are displayed only on 16 Gbps-capable platforms and not on 32 Gbps-capable platform. The following fields are displayed only on 32 Gbps platforms: lat_tot_pkt_vc, lat_hi_time_vc, lat_lo_time_vc, and latency_dma_ts.
portTest - This command is supported on the N->N Loopback Ports and it is not supported on the F_Ports on VF-enabled switch.
powerOffListSet - Updated the command example. powerOffListShow - Updated the command example. reboot - Added details for Brocade X6 Director. secCertUtil - Added the following options: -hash, https, -type, -years, -nowarn. secCryptoCfg - Added new options to manage template files. sfpShow - Corrected command example for QSFP. slotShow - Added new blade IDS: 175, 177, 178, and 186. Removed unsupported blade IDs. snmpConfig - This command has been enhanced to run with command line options
(non-interactive).
spinFab - This command is supported on AE_Ports and not supported on core blade connected to port blade.
sshUtil - Added the following options: genhostkey, showhostkey, and deletehostkey. Added -all option for the delknownhost operand.
switchCfgSpeed - Added 32 Gbps speed. switchName - The command is enhanced to accept switch name beginning with number. switchShow - Added the following disabled reasons: Disabled (EX_Port IR POD License Limit
Exceeded), Disabled (License not Installed for Integrated Routing), and Disabled (Incompatible AMP Version). Added ESC mismatch, AMP Version Conflict and Incompatible AMP Version segmentation reasons.
traceDump - Added the Reboot tracedump type. turboRamTest - Removed the ceeturboramtest command. userConfig - Added -at | -access option. An asterisk (*) next to the account name in the --show
and -a output indicates that the password for that user account is still at the default value.
Deprecated commands bpPortLoopbackTest bpTurboRamTest ceePortLedTest ceePortLoopbackTest
Brocade Fabric OS Command Reference xxv53-1004112-01
-
ceeTurboRamTest cmsh fcoe fcoeLoginCfg fcoeLoginGroup iclCfg ifModeSet ifModeShow portMirror
CLI usage conventions Some Fabric OS show commands display certain switch or fabric components in three-digit
decimal numbers, for example, 003. When you use these numeric identifiers as inputs to other commands, you must remove the leading zeros; otherwise the commands will either fail or generate incorrect results. Adding zeros to any decimal number in a command input will cause that number to be treated as an Octal number.
The entire command line (both commands and options) is case-sensitive. Selected command names and options may also support Java-style capitalization. Java-style capitalization means that while bannershow and bannerShow will both work, BANNERSHOW and BannerShow will not. The options of commands on the other hand, are strictly case sensitive and therefore only lower case or Java-style capitalization can be entered depending on each option. This means that while the -USB option of the configDownload command works, but -usb will not. Refer to each syntax for explicit instructions on supported capitalization for each command and options.
When command examples in this guide show user input enclosed in quotation marks, the quotation marks are required. Example: zonecreate zonename requires that the value for zonename be in quotation marks.
Automatic page breaks in CLI command output displays are being phased out. Use the more option to display command output with page breaks: command | more. Do not use the more option in conjunction with help pages. Executing help command | more will display a no manual entry for command message.
xxvi Brocade Fabric OS Command Reference53-1004112-01
-
Brocade Fabric OS Command Reference53-1004112-01
Chapter
1
Using Fabric OS CommandsUsing the command line interfaceThe Fabric OS command line interface (CLI), accessed via Telnet, SSH, or serial console, provides full management capability on a Brocade switch. The Fabric OS CLI enables an administrator to monitor and manage individual switches, ports, and entire fabrics from a standard workstation. Selected commands must be issued from a secure Telnet or SSH session.
Access is controlled by a switch-level password for each access level. The commands available through the CLI are based on the users login role and the license keys used to unlock certain features.
The Fabric OS CLI provides the following capabilities:
Access to the full range of Fabric OS features, given the license keys installed. Assistance with configuration, monitoring, dynamic provisioning, and daily management of
every aspect of storage area networks (SANs). A deeper view of the tasks involved in managing a Brocade SAN. Identification, isolation, and management of SAN events across every switch in the fabric. Management of Brocade licenses.The documentation for each command includes a synopsis of its syntax, a description of command use, and a set of examples. The same information can be accessed by issuing the help command followed by the command name on a Brocade switch or director. This command displays the help page for the specified command. For example, to display the help page for portCfg, enter:
switch:admin> help portCfg
Understanding Role-Based Access ControlFabric OS implements Role-Based Access Control (RBAC) to control access to all Fabric OS operations.
Eight predefined roles are supported, as described in Table 1. These predefined role definitions are guided by perceived common operational situations and the operations and effects a role is permitted to have on a fabric and individual fabric elements.
TABLE 1 Role definitions Role name Definition
User Non-administrative use, such as monitoring system activity. In Fabric OS v6.2.0 and later, the user account gains access to Fabric ID 128. This is the default logical fabric after a firmware upgrade.
Operator A subset of administrative tasks typically required for routine maintenance operations.
SwitchAdmin Administrative use excluding security, user management, and zoning.
1
-
Understanding Virtual Fabric restrictions1
In addition to these predefined roles, Fabric OS v7.0.0 and later provides support for creating user-defined roles. Refer to the roleConfig command for more information.
Additional command restrictions apply depending on whether Virtual Fabrics are enabled in a fabric. Refer to Appendix A, Command Availability.
Understanding Virtual Fabric restrictionsAll Fabric OS commands are subject to additional RBAC enforcement with regard to Virtual Fabric contexts and switch types. Commands can be executed in one or more of the contexts described in Table 2. TABLE 2 Virtual Fabric contexts
Context type Definition
Switch context Command applies to the current logical switch only, or to a specified logical switch.
Chassis context Command applies to the chassis on which it is executed.
Switch and chassis context Command can be executed in a logical switch context or in a chassis context.
Disallowed Command is not supported in Virtual Fabric mode.
Execution of chassis commands requires chassis permissions.
Switch commands are further defined by the switch type restrictions as described in Table 3. Switch type restrictions are not applicable to commands that require chassis permissions.
TABLE 3 Switch types Switch type Definition
All Switches Command can be executed in any switch context.
Base Switch Only Command can be executed only on the base switch.
Default Switch Only Command can be executed only on the default switch.
N/A Command is a chassis command or not supported in Virtual Fabric mode.
In a Virtual Fabric environment where contexts are enforced, the following Virtual Fabric restrictions apply to the RBAC permissions specified in Table 1. Refer to the userConfig command for more information on configuring user account access permissions in a Virtual Fabric environment.
Any given role is allowed to execute all switch commands to which the role is authorized in the accounts home context. The default home context is the default logical fabric FID 128.
You can change an accounts home context to a specified FID and configure the account permissions to access additional logical switches specified in the users Fabric ID list.
ZoneAdmin Zone management only.
FabricAdmin Administrative use excluding user management management.
BasicSwitchAdmin
A subset of administrative tasks, typically of a more limited scope and effect.
Admin All administrative tasks, including encryption and chassis commands.
SecurityAdmin Administrative use including admin, encryption, security, user management, and zoning.
TABLE 1 Role definitions (Continued)Role name Definition
2 Brocade Fabric OS Command Reference53-1004112-01
-
Determining RBAC permissions for a specific command 1
Accounts with user or admin permissions can be granted chassis permissions. A user account with the chassis role can execute chassis-level commands at the user RBAC access level. An admin account with the chassis role can execute chassis-level commands at the admin RBAC access level.
Use the classConfig --showcli command to look up the Virtual Fabrics context for a specified command. Refer to Appendix A, Command Availability, for a complete listing of Virtual Fabric restrictions that apply to the commands included in this manual.
Determining RBAC permissions for a specific commandTo determine RBAC permission for a specific command, use the classconfig command.
1. Enter the classconfig --showcli command for a specified command.
The command displays the RBAC class and access permissions for each of the command options. Note that options for a single command option can belong to different classes.
2. Enter the classconfig --showroles command and specify the RBAC class of the command option you want to look up.
The command displays the default roles and the permissions they have to access commands in the specified RBAC class.
The following example shows how you can obtain permission information for the zone command. Suppose you want to know if a user with the SwitchAdmin role can create a zone. You issue the classconfig --showcli command for the zone command, which shows that the zone --add command belongs to the RBAC class zoning. You then issue the classconfig --showroles command for the zoning RBAC class. The output shows that the SwitchAdmin role has Observe (O) permissions only for any command in the zoning class. This means that the user with the SwitchAdmin role is not allowed to create zones. To allow this user to create a zone, you must change the users access to any of the roles that have observe and modify (OM) access. Use the userConfig command to change the users role or use the roleConfig command to create a custom role.
switch:admin> classconfig --showcli zoneCLI Option Permission RBAC Class Context----------------------------------------------------------zone Killall OM Debug vfzone evlogclear OM Debug vfzone evlogshow O Debug vfzone evlogtoggle OM Debug vfzone mergeshow O Debug vfzone stateshow O Debug vfzone activate OM Zoning vfzone add OM Zoning vfzone copy OM Zoning vfzone create OM Zoning vfzone deactivate OM Zoning vf(output truncated)
switch:admin> classconfig --showroles zoningRoles that have access to the RBAC Class 'zoning' are:
Role Name Permission --------- ---------- User O Admin OM
Brocade Fabric OS Command Reference 353-1004112-01
-
Determining RBAC permissions for a specific command1
Factory OM Root OM Operator O SwitchAdmin O ZoneAdmin OM FabricAdmin OM BasicSwitchAdmin O SecurityAdmin O
NOTEIf a Role Name does not appear in the list, it indicates that the role is not available to the specified class and associated commands in that class are restricted and cannot be executed in that role.
4 Brocade Fabric OS Command Reference53-1004112-01
-
Brocade Fabric OS Command Reference53-1004112-01
Chapter
2
Fabric OS CommandsaaaConfig
Manages RADIUS, LDAP, and TACACS+ configuration information.
SYNOPSIS aaaconfig
aaaconfig --show
aaaconfig --add | --change server -conf radius | ldap | tacacs+ [-p port] [-d domain] [-t timeout] [-s secret] [-a chap | pap | peap-mschapv2] [-e encr_type]
aaaconfig --remove server -conf radius | ldap | tacacs+
aaaconfig --move server -conf radius | ldap | tacacs+ to_position
aaaconfig --authspec aaa1[;aaa2 [-backup] [-nologout]
aaaconfig --help
DESCRIPTION Use this command to manage the RADIUS, LDAP, and TACACS+ server configuration for the authentication, authorization and accounting (AAA) services. Use this command to display, add, remove, change, enable or disable the RADIUS, LDAP, or TACACS+ configuration.
Brocade switches use a local as well as a remote authentication mechanism for validating a login. Supported authentication protocols include Password Authentication Protocol (PAP), Challenge-Handshake Authentication Protocol (CHAP) and Protected Extensible Authentication Protocol (PEAP). Light-weight Directory Access Protocol (LDAP) authentication against Active Directory for user authentication and authorization is supported.
RADIUS, LDAP or TACACS+ servers are contacted in the order they appear in the configuration list. The first server returning authentication success or failure causes the authentication request to succeed or fail. If no response is received within the specified timeout, the next RADIUS, LDAP, or TACACS+ server in the list is contacted. An event entry logs if all RADIUS, LDAP, or TACACS+ servers fail to respond.
When the command succeeds, it triggers an event log (the Fabric OS error log) to indicate a server is added, removed, or modified. Refer to the Fabric OS Message Reference manual for specific details.
There are two modes of operation in LDAP authentication, FIPS mode and non-FIPS mode. However, there is no option to configure LDAP while the switch is in FIPS mode. The LDAP client checks if FIPS mode is set on the switch and uses FIPS-compliant TLS ciphers for LDAP. If FIPS mode is not set and the ADir server is configured for FIPS ciphers, it uses FIPS-compliant ciphers.
Configuration changes are persistently saved and take effect with the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains.
NOTES Customers can use centralized RADIUS servers to manage AAA services for a switch, as defined in the RFC 2865 RADIUS specification.
This command can be executed when logged in through the console, Telnet or SSH connection.
5
-
aaaConfig22
The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details.
OPERANDS This command has the following operands:
serverSpecifies an IP address or a server name in dot-decimal notation. IPv6 addresses are supported. If a name is used, a DNS entry must be correctly configured for the server. If the specified server IP address or name already exists in the current configuration, the command fails and generates an error. However, the command does not validate the server name against the IP address in the configuration. Make sure to avoid duplicate configuration of the same server, one specified by the name, the other specified by the IP address.
--showDisplays the current AAA service configuration.
--add | --change server [options]Adds or modifies a RADIUS, LDAP, or TACACS+ server. The --add option appends the specified server to the end of the current configuration list. A maximum of 5 servers are supported for each authentication type. The --change option modifies the specified server configuration to use the new arguments. The server must be one of the IP addresses or names shown in the current configuration.
The following options are supported:
-conf radius | ldap | tacacs+Specifies the server configuration as either RADIUS, LDAP, or TACACS+. This operand is required.
The following operands are optional:
-p portSpecifies the RADIUS, LDAP, or TACACS+ server port number. Supported range is 1 to 65535. The default port is 1812 for RADIUS authentication. The default port is 1813 for RADIUS accounting. The default port is 389 for LDAP authentication. The default port is 49 for TACACS+ authentication. This operand is optional. If no port is specified, the default is used.
-t timeoutSpecifies the response timeout for the RADIUS, the LDAP or the TACACS+ server. The supported range is 1 to 30 seconds. The default is 3 seconds. This operand is optional. If no timeout is specified, the default is used.
-d domainSpecifies the Windows do