FlexFrameBreaking New Ground in UV Performance

Digital Core eDrivers for UV Lamps

TM

Page 2: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

FlexFrame Technology and Connectivity.

FlexFrame is the ideal, simplified, new

digital way of communication tailored

to to the needs of present day lighting

technology. Communication and

installation have been simplified as much

as possible. All intelligent components

communicate in a local system in a

way that is both simple and free of

interference. The FlexFrame standard

provides a full system solution for

fixture, lamp and ballast. The advantages

of FlexFrame are many, benefiting

everyone from the fixture manufacturer,

facility manager and the bottom line of

the building occupant.

FlexFrame is an open architecture that

allows communication bi-directionally

via a gateway or transmitter. The

FlexFrame system configuration

can be readily modified without any

modification of the installation itself.

The FlexFrame Digital Core eDriver

utilizes standard open communication

protocol. Within the FlexFrame system,

each eDriver has its own address and

each address individually communicates

with the control device. eDriver's can

also be indivdually configured to identify

various parameters such as power on,

light levels and system failure.

FlexFrame stand-alone and multi-lamp UV lighting solutons, ready to suit your needs.

Secure performance and peace of mind knowing that the FlexFrame eDriver offers the highest reliability, enabling maximum protection of water and air quality.

FlexFrame Architectural Design

FlexFrame as a concept, stands for an

intelligent lighting management system

that provides increased energy savings,

easier installation and maintenance,

and maximum control and retrofit

flexibility to an entirely new standard.

The FlexFrame Digital Core eDriver is a

completely new kind of technology with

microprocessor-based technology that

delivers a genuine, quantum leap in Ultra

Violet lamp performance. So follow along,

as we present the possibilities created by

the FlexFrame Architecture.

With the introduction of FlexFrame

Digital Core eDriver for Ultra

Violet systems, Robertson has

established totally new benchmarks for

performance and cost savings. The key to

understanding the dynamic, multifaceted

value of FlexFrame is the ability to

monitor the lamp/system.

Tailored control for when, where, and how you want it.

FlexFrame 300TM

Page 3: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

3 www.RobertsonLighting.com

PROGRAM START eDRIVER LOW PRESSURE AMALGAM LAMPS

Performance• Digital Core Electronic• 6 second preheat start time• Series lamp connection• Normal power factor• Dynamic auto-select of analog or digital connection• Meets FCC Part 18 (Class A)• Meets ANSI standard C82.11• Meets ANSI standard C62.41• IP61 Rated

Application• Max. case temp: 176ºF/80ºC• Max. ambient temp: 122ºF/50ºC• Min. starting temp: 0ºF/-18ºC• Lamp starts: >50,000• Remote mounting: 20 ft.

Safety• UL/935: (Class P, Type CC)• CSA (cUL) certified• Dynamic thermal protection• Internally fused• Internal surge protection

FlexFrame 800Afor 2 GPHVA1554T6L thru GPHHA1554T6L UV Lamps Program Start, 208 -277Vac, 50-60Hz.

Specifications

Line Voltage

(V)

No. of

LampsLamp Type

Approx. Lamp Length

Lamp Watts

Arc Voltage

(A)

Arc Current

(mA)

Line Current

(A)

Input Power (W)

Power Factor

Max Current THD (%)

Current Crest Factor

Electrical Efficiency

2082 GPHVA1554T6L 61” 240 100-200 1800

2.50 516≥0.90 ≤10% ≤1.60

0.93277 1.81 500 0.96208

2 GPHVA1554T6L 61” 320 100-200 21003.35 695

≥0.90 ≤10% ≤1.600.92

277 2.43 673 0.95208

2 GPHVA1554T6L 61” 400 100-200 24004.20 869

≥0.90 ≤10% ≤1.600.92

277 3.10 851 0.94

Standard lead lengths and tolerance:• (1) Black: 12” • (4) Red: 12”• (1) White: 12” • (4) Blue: 12”• (1) Green: 12”Tolerance +2.00 -1.00, Strip 0.375”, Tolerance +0.06

H W L M1 S2 3/8 4" 11 3/4" 11" 1/42.35 4.00 11.75 11.00 0.31

5.97 cm 10.16 cm 29.85 cm 27.94 cm 0.79 cm

Physical• Open frame assembly• Aluminum plate• PCB conformal coating

Options• LED power status indicator• LED lamp status indicator• Digital* control & comprehensive

software communication toconveniently manage and accessyour lighting network remotely.

• Analog serial control port for0-10V dimming

* USBR bridge RS485 to USB adaptorrequired for digital option control.

Dimensions & Wiring Diagram

To protect and secure citizens and surroundings of harmful contaminates it is essential that municipalies deactivate the

microorganisms in water effetively.

Page 4: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

4www.RobertsonLighting.com

PROGRAM START eDRIVER LOW PRESSURE AMALGAM LAMPS

Performance• Digital Core Electronic• 6 second preheat start time• Normal power factor• Dynamic auto-select of analog

or digital connection• Meets FCC Part 18 (Class A)• Meets ANSI standard C82.11• Meets ANSI standard C62.41• IP61 Rated

Application• Max. case temp: 176ºF/80ºC• Max. ambient temp: 122ºF/50ºC• Min. starting temp: 0ºF/-18ºC• Lamp starts: >50,000• Remote mounting: 20 ft.

FlexFrame 400Aor 1 GPHA835TL thru GPHHA1554T6L UV Lamps Program Start, 120 -277Vac ±10%, 50-60Hz.

SpecificationsLine

Voltage (V)

No. of

LampsLamp Type

Approx. Lamp Length

Lamp Watts

Arc Voltage

(A)

Arc Current

(mA)

Line Current

(A)

Input Power (W)

Power Factor

Max Current THD (%)

Current Crest Factor

Electrical Efficiency

1201 GPHA843T5L 33” 240 100-200 1800

2.00 260≥0.90 ≤10% ≤1.60

0.93277 0.92 253 0.95120

1 GPHA1000T5L 39” 320 100-200 21002.80 347

≥0.90 ≤10% ≤1.600.92

277 1.15 338 0.95208

1 GPHA1554T5L 61” 400 100-200 24002.00 430

≥0.90 ≤10% ≤1.600.93

277 1.50 425 0.94120

1 GPHA843T6L 33” 240 100-200 18002.00 260

≥0.90 ≤10% ≤1.600.93

277 0.92 253 0.95120

1 GPHA1000T6L 39” 320 100-200 21002.80 347

≥0.90 ≤10% ≤1.600.92

277 1.15 338 0.95208

1 GPHVA1554T6L 61” 400 100-200 24002.00 430

≥0.90 ≤10% ≤1.600.93

277 1.50 425 0.94120

1 GPHHA843T6L 33” 240 100-200 18002.00 260

≥0.90 ≤10% ≤1.600.93

277 0.92 253 0.95120

1 GPHHA1000T6L 39” 320 100-200 21002.80 347

≥0.90 ≤10% ≤1.600.92

277 1.15 338 0.95208

1 GPHHVA1554T6L 61” 400 100-200 24002.00 430

≥0.90 ≤10% ≤1.600.93

277 1.50 425 0.94

Standard lead lengths and tolerance:• (1) Black: 12” • (2) Red: 12”• (1) White: 12” • (2) Blue: 12”• (1) Green: 12”Tolerance +2.00 -1.00, Strip 0.375”, Tolerance +0.06

H W L M1 S2 3/8 4" 11 3/4" 11" 1/42.35 4.00 11.75 11.00 0.31

5.97 cm 10.16 cm 29.85 cm 27.94 cm 0.79 cm

Safety• UL/935: (Class P, Type CC)• CSA (cUL) certified• Dynamic thermal protection• Internally fused

• Internal surge protection

Physical• Open frame assembly• Aluminum plate• PCB conformal coating

Options• LED power status indicator• LED lamp status indicator• Digital* control & comprehensive

software communication toconveniently manage and accessyour lighting network remotely.

• Analog serial control port for0-10V dimming

* USBR bridge RS485 to USB adaptorrequired for digital option control.

Dimensions & Wiring Diagram

Page 5: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

5 www.RobertsonLighting.com

INSTANT START eDRIVER LOW PRESSURE MERCURY LAMPS

Performance• Digital Core Electronic• 2 second preheat start time• Parallel lamp connection• Normal power factor• Dynamic auto-select of analog or digital connection• Meets FCC Part 18 (Class A)• Meets ANSI standard C82.11• Meets ANSI standard C62.41• IP61 Rated

Application• Max. case temp: 176ºF/80ºC• Max. ambient temp: 122ºF/50ºC• Min. starting temp: 0ºF/-18ºC• LED power status indicator• Lamp starts: >50,000• Remote mounting: 20 ft.

Safety• UL/935: (Class P, Type CC)• CSA (cUL) certified• Dynamic thermal protection• Internally fused• Internal surge protection

FlexFrame 300for 2 G64T5HO UV LampsEnergy Limited Instant Start, 120 -277Vac, 50-60Hz.

Specifications

Line Voltage

(V)

No. of

LampsLamp Type

Approx. Lamp Length

Lamp Watts

Arc Voltage

(A)

Arc Current

(mA)

Line Current

(A)

Input Power (W)

Power Factor

Max Current THD (%)

Current Crest Factor

Electrical Efficiency

108

2 G64T5HO 61” 155 194/189 800

2.97 319

≥0.98≤10% ≤1.60

0.91120 2.65 317 0.92132 2.38 314 0.93240 1.29 308 0.95277 1.13 307

≥0.900.95

300 1.05 306 0.95

Standard lead lengths and tolerance:• (1) Black: 12” • (2) Red: 12”• (1) White: 12” • (2) Blue: 12”• (1) Green: 12”Tolerance +2.00 -1.00, Strip 0.375”, Tolerance +0.06

H W L M1 S1 7/8 3" 11 3/4" 11 1/8" 1/41.87 3.00 11.69 11.10 0.31

4.75 cm 7.65 cm 29.69 cm 28.19 cm 0.79 cm

Physical• Open frame assembly• Aluminum plate• PCB conformal coating

Options• LED lamp status indicator• ON/OFF rocker switch• Digital* control & comprehensive

software communication toconveniently manage and accessyour lighting network remotely.

• Analog serial control port for0-10V dimming

* USBR bridge RS485 to USB adaptorrequired for digital option control.

Dimensions & Wiring Diagram

UV curing offers commercial printers many benefits such as dramatically improved physical properties in inks, coatings and adhesives. Faster production speeds and reduction of work-in-process. Dramatically reduced set-up/clean-up labor and increase yield and reduce scrap.

Page 6: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

6www.RobertsonLighting.com

INSTANT START eDRIVER LOW PRESSURE MERCURY LAMPS

Performance• Digital Core Electronic• 2 second preheat start time• Parallel lamp connection• Normal power factor• Six pin jumper connector for drive current selections of 750/800/850/900/950/1000 mA• Meets FCC Part 18 (Class A)• Meets ANSI standard C82.11• Meets ANSI standard C62.41• IP61 Rated

Application• Max. case temp: 176ºF/80ºC• Max. ambient temp: 122ºF/50ºC• Min. starting temp: 0ºF/-18ºC• LED power status indicator• Lamp starts: >50,000• Remote mounting: 20 ft.

Safety• UL/935: (Class P, Type CC)• CSA (cUL) certified• Dynamic thermal protection• Internally fused• Internal surge protection

FlexFrame 300AQfor 2 G64T5HO UV LampsEnergy Limited Instant Start, 120 -277Vac, 50-60Hz.

Specifications

Line Voltage

(V)

No. of

LampsLamp Type

Approx. Lamp Length

Lamp Watts

Arc Voltage

(A)

Arc Current

(mA)

Line Current

(A)

Input Power (W)

Power Factor

Max Current THD (%)

Current Crest Factor

Electrical Efficiency

108

2 G64T5HO 61” 155 194/189 800

2.97 319

≥0.98≤10% ≤1.60

0.91120 2.65 317 0.92132 2.38 314 0.93240 1.29 308 0.95277 1.13 307

≥0.900.95

300 1.05 306 0.95

Physical• Open frame assembly• Aluminum plate• PCB conformal coating

Options• Mesh covering• LED power status indicator• LED lamp status indicator• ON/OFF rocker switch• Molex connectors

FlexFrame 300AQ with options shown

Standard lead lengths and tolerance:• (1) Black: 6” • (2) Red: 15”• (1) White: 6” • (2) Blue: 15”• (1) Green: 6”Tolerance +2.00 -1.00, Strip 0.375”, Tolerance +0.06

H W L M1 S1 7/8 3" 11 3/4" 11 1/8" 1/41.87 3.00 11.69 11.10 0.31

4.75 cm 7.65 cm 29.69 cm 28.19 cm 0.79 cm

Dimensions & Wiring Diagram

100mA 850mA

950mA 800mA

900mA 750mA

Pin Header & LED Indicator

Six pin jumper connector

Page 7: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

7 www.RobertsonLighting.com

PROGRAM START LOW VOLTAGE eDRIVER LOW PRESSURE MERCURYLAMPS

Performance• Digital Core Electronic• 6 second preheat start time• Power factor corrected• Dynamic auto-select of analog or digital connection• Meets FCC Part 15 (Class B)• Meets ANSI standard C82.11• Meets ANSI standard C62.41• IP61 Rated

Application• Max. case temp: 176ºF/80ºC• Max. ambient temp: 140ºF/60ºC• Min. starting temp: 0ºF/-18ºC• LED power status indicator• LED lamp status indicator• Lamp starts: >50,000• Remote mounting: 20 ft.

Safety• UL/935: (Class P, Type CC)• CSA (cUL) certified• Inherent thermal protection• Internal surge protection

FlexFrame 50LVfor 1 GPH212T5 thru GPH287T5 UV LampsProgram Start, 12*-24AC/DC, 50-60Hz. *Rated at half of its rated power at 12AC

Specifications

Line Voltage (V)

No. of

LampsLamp Type

Approx. Lamp Length

Lamp Watts

Arc Voltage

(A)

Arc Current

(mA)

Line Current

(A)

Input Power (W)

Power Factor**

Max Current THD (%) **

Current Crest Factor

Electrical Efficiency

24AC/DC 1 GPH212T5 8" 10 20 400 0.48 11 ≥0.80 ≤10% ≤1.6 0.74

24AC/DC 1 GPH287T5 11" 14 29 400 0.71 16 ≥0.90 ≤10% ≤1.6 0.78

24AC/DC 1 GPH357T5 14" 17 35 400 0.78 18 ≥0.90 ≤10% ≤1.6 0.81

24AC/DC 1 GPH383T5 15" 18 41 400 0.90 21 ≥0.90 ≤10% ≤1.6 0.80

24AC/DC 1 GPH406T5 16" 19 39 400 0.91 19 ≥0.90 ≤10% ≤1.6 0.80

24AC/DC 1 GPH436T5 17" 21 42 400 0.92 21 ≥0.90 ≤10% ≤1.6 0.84

24AC/DC 1 GPH463T5 18" 22 44 400 0.94 22 ≥0.90 ≤10% ≤1.6 0.84

24AC/DC 1 GPH512T5 20" 24 55 400 1.05 25 ≥0.90 ≤10% ≤1.6 0.84

24AC/DC 1 GPH587T5 23" 26 57 400 1.08 26 ≥0.90 ≤10% ≤1.6 0.86

24AC/DC 1 GPH843T5 33" 41 83 400 1.60 38 ≥0.90 ≤10% ≤1.6 0.86

12AC/DC 1 GPH212T5 8" 9 21 400 1.00 11 ≥0.90 ≤10% ≤1.7 0.70

12AC/DC 1 GPH287T5 11" 14 30 400 1.57 18 ≥0.90 ≤10% ≤1.7 0.66

Standard lead lengths and tolerance:• (1) Black: 12” • (2) Red: 18”• (1) White: 12” • (2) Blue: 18”• (1) Green: 12”Tolerance +2.00 -1.00, Strip 0.375”, Tolerance +0.06

H W L M1 S1 3/8 3" 5" 4 5/8" 1/41.34 3.00 5.00 4.65 0.25

3.71 cm 7.62 cm 12.70 cm 11.81 cm 0.64 cm

Physical• White powder coat steel• Encased and potted

Options• Digital* control & comprehensive

software communication toconveniently manage and accessyour lighting network remotely.

• Analog serial control port for0-10V dimming

* USBR bridge RS485 to USB adaptorrequired for digital option control.

Dimensions & Wiring Diagram

The quality of the air we breathe has a profound effect on our health and well-being. Households can purify their air by installing air purifiers with UV air purification lamps, which can render germs that float through the air harmless.

**Only applies during AC operation

Page 8: Breaking New Ground in UV Performance - Amazon S3Brochure_RL… · FlexFrame Technology and Connectivity. FlexFrame is the ideal, simplified, new digital way of communication tailored

www.RobertsonLighting.com RL010917

© 2017 Robertson Worldwide - All rights reserved. Reproduction in whole or part is prohibited without the prior written consent of the copyright owner.

While the information provided in this document is believed to be accurate, it is under development and Robertson Worldwide reserves the right to make changes without further notice to the product described herein to improve reliability, function, or design, and makes no guarantee or warranty concerning the accuracy of said information, nor shall it be responsible for any loss or damage of whatever nature resulting from the use of, or reliance upon, such information.

Robertson Worldwide l 1605 Main Street, Suite 700 l Sarasota, Fl 34236