boq lotus hotel final 080709
DESCRIPTION
BOQTRANSCRIPT
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountDivision 02 Site Construction
Excavation
2.1
m3 16000
Backfilling
2.2LS LS
Road Base
2.3LS LS
2.4 Anti termite treatment LS 1
Shoring Piles
2.5no. 131
2.6no. 56
Pile Cap
2.7m3 65
2.8m3 13
Precast Panels
2.9
LM 150
*Price shall include dewatering (if required)
Excavation for foundations, the price (rate) includes disposal of excavation extract to the general disposal area. Also, the price includes disposal of under ground water. So translate any infrastracture excavation at any type of soil. Excavation Foundation Level
Backfiling to the required levels, compaction and according to the specification required and the drawings.
Road Base as required by the specifications and soil report under foundations
Reinforced concrete piles with 90 cm diameter and required length for retaining wall shoring
Reinforced concrete piles with 60 cm diameter and required length for retaining wall shoring
Reinforced concrete capping beam with 90x60 cm cross section (above shoring piles).
Reinforced concrete capping beam with 60x60 cm cross section (above shoring piles).
Precast concrete panels with 90 cm height and 10 cm thick. Price
includes (steel I beam 203x203x46 kg/m) at 2.00 m spacing c/c
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 02 0.00Division 03 - Concrete
Concrete for Super Structure
3.1 Columns Class A (cube strength 35N/mm2) m3 520
3.2 Lift Walls Class A (cube strength 35N/mm2) m3 1230
3.3 Solid Slabs Class A (cube strength 35N/mm2) m3 1757
3.4 Post-tension slabs m3 2343
3.5 Beams Class A (cube strength 35N/mm2) m3 70
3.6 Fire Stairs Class A (cube strength 35N/mm2) LS LS
3.7 Swimming Pool Class A (cube strength 35N/mm2) LS LS
Rafts
3.8m3 140
3.9m3 550
Retaining walls
3.10 Reinforced retaining wall with 30 cm width. m3 455
3.12 Water tanks LS LS
3.13
m2 166
Concrete work including form work, shuttering and reinforcement steel (Qatary or equal approved) for all work, compound wall, entrances, service area, and the like
Plain concrete raft with 10 cm thickness (under RC raft) Class A (cube strength 35N/mm2)
Reinforced concrete raft with 130 cm thick Class A (cube strength 35N/mm2)
Supply and apply interlocking paving for pavement including backfilling to the required levels and compaction and according to the specification required and DM
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 03 0.00
Division 04 Masonry
All masonry works shall include lintels are bond beams
4.1 Cement Block 60 Cm Thick m2 350
4.2 Cement Block 50 Cm Thick m2 150
4.3 Cement Block 25 Cm Thick m2 650
4.4 Cement Block 20 Cm Thick m2 12000
4.5 Cement Block 15 Cm Thick m2 2150
4.6 Cement Block 10 Cm Thick m2 3500
4.7LS LS
4.8 Concrete lintels with variables cross sections LS LS
Concrete blocks ASTM C90 including single and double wythe reinforcement, anchors, flexible fillers, butterflies, grouting, sealants reinforcing steel as required and mentioned in specifications 04200 and drawing details
All masonry works shall include coves, niches, arches and the like as shown in drawings.
Cement soild block 20 cm thick to fix water proof membrane behind (water tank, swimming pool and piles caps) walls.
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 04 0.00Division 05 Metal
Handrails for Service Stairs
5.1
LM 45
Handrails for Fire Stairs
5.2
LM 160
Service Steel 2
5.3LS LS
Service Steel 1
5.4LS LS
Handrails for façade
5.5LM 100
Garbage Chute
5.6LS LS
Main Entrance Canopy
5.7
LS LS
Stainless Steel
5.8LS LS
5.9LS LS
Supply and apply of the steel railing system including 60 mm diameter steel handrail in epoxy paint finish, complete according to details
Supply and apply of the steel railing system including 12mm diameter steel bar horizontal / diagonal railing fully welded to vertical steel stand / 50mm diameter vertical steel pipe stand in spray paint, complete according to details
Supply and apply of steel cantilever plates / angled framing for the service stair, complete according to details
Supply and apply of steel cantilever plates / angled framing for the service stair, complete according to details
Supply and apply of 100 cm height powder coated aluminum railing for the external facades
Supply and apply of 0.16 cm thick x 60 cm diameter stainless steel garbage chute as per manufacturer's standard
Supply and apply of main entrance canopy including (di-cast 20x15 cm aluminum extruded rectangular tube pergola frame with aluminum channel stiffener / 1 cm thick clear tempered glass / aluminum louver / aluminum flashing) including steel connector ring and steel tension rod, according to the details
Supply and apply of stainless steel plate according to typical jamb detail
Supply and apply of stainless steel cladding for two columns at main entrance
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 5 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Division 06 - Wood and Plastics
Cancelled
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 6 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountDivision 07 - Thermal and Moisture Protection
7.1
m2 1120
7.2m2 2000
7.3 Ditto for basement horizontally and vertically m2 1350
7.4 Ditto for roofs m2 1300
7.5 Anti ulga and non toxic water proofing paint for inside water tank m2 475
7.6
m2 1115
Thermal Insulation
7.7 50mm thick extruded polystyrene sheets for roofs. m2 1300
7.8 Ditto for external walls,beams & columns. m2 LS
Fire and Smoke Protection
7.9
LS LS
Joint sealants
7.10LS LS
Moisture Isolation Waterproof Coat / Membrane 4mm thick, reinforced with polyester
Supply and apply all the next items. The price include furnish all necessary labor, materials, tools and etc. to complete works
Supply and install 1000 gauge polythenes sheet with 150mm side and end laps at joints under PC foundations and RCC (BRC) floor
Supply and apply moisture isolation water proofing coat/membrane 4mm thick reinforced with polyester
High performance polymer modified bituminous water proofing membranes reinforced with polymetric film single layer for bathrooms, toilets and kitchens.
Supply and install fire stop and smoke seal for all ducts, shafts, openings, masonry control and deflection joints and fire rated zones
Joint sealants for control joints as shown in the drawings and as per engineers recommendation
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 7 0.00Division 08 Doors and Windows
Wood Doors
Double Leaf
8.1 Type WD02 Size (120x240) cm no. 22
8.2 Type WD03 Size (120x240) cm no. 157
8.3 Type WD08 Size (180x240) cm no. 11
8.4 Type WD09 Size (180x240) cm no. 1
8.5 Type WD10 Size (150x240) cm no. 14
8.6 Type WD11 Size (150x240) cm no. 1
8.7 Type WD15 Size (120x240) cm no. 1
Single Leaf
8.8 Type WD04 Size (70x200) cm no. 24
8.9 Type WD05 Size (90x240) cm no. 156
8.10 Type WD06 Size (90x240) cm no. 15
8.11 Type WD07 Size (90x240) cm no. 30
8.12 Type WD12 Size (90x240) cm no. 9
Supply and apply aluminum door
8.13 Type LD01 Size (300x370) cm no. 1
8.14 Type LD02 Size (180x240) cm no. 8
8.15 Type LD04 Size (180x240) cm no. 4
8.16 Type LD05 Size (225x570) cm no. 1
8.17 Type LD06 Size (120x240) cm no. 2
Manufactured by reputed carpentry workshop and as approved by Engineer and shown interior design drawings. Item will include all ironmongery(PC - Rate 500.00 AED)and master key system three levels.
Aluminum electrostatic powder coated doors including hardware "Schuco International" installed by approved installer, "Alico" or other equal approved, item include double glazing and 6mm clear glass inside with heat mirror film HC75 in between staint gobain and sealants, gaskets, master key three levels and the like as approved by engineers and manufacturer as as specified in the general specifications. All items includes fly screens.
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
8.18 Type LD07 Size (see door elevation) no. 1
Total Amount of Division 8 - P1 Err:522
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountContu. Division 08 Doors and WindowsFollow supply and apply aluminum door
8.19 Type LD09 Size (180x895) cm no. 1
8.20 Type LD11 Size (see door elevation) cm no. 1
8.21 Type LD12 Size (80.5x240) cm no. 1
8.22 Type LD13 Size (525x310) cm no. 1
8.23 Type LD14 Size (340x370) cm no. 1
8.24 Type LD14A Size (340x310) cm no. 1
8.25 Type LD14B Size (340x370) cm no. 1
8.26 Type LD14C Size (380x370) cm no. 1
8.27 Type LD15 Size (265x370) cm no. 1
8.28 Type LD16 Size (180x465) cm no. 1
8.29 Type LD17 Size (150x300) cm no. 1
8.30 Type LD18 Size (485x340) cm no. 1
8.31 Type LD19 Size (180x480) cm no. 1
Suppy and apply glazzed door
8.32 Type GD01 Size (320x465) cm no. 1
8.33 Type GD05 Size (180x310) cm no. 7
8.34 Type GD06 Size (430.8x310) cm no. 7
8.35 Type GD06A Size (380x380) cm no. 8
8.36 Type GD07 Size (380x390) cm no. 7
8.37 Type GD08 Size (180x240) cm no. 21
8.38 Type GD09 Size (141.3x310) cm no. 6
8.39 Type GD10 Size (265x3100) cm no. 6
8.40 Type GD11 Size (70x200) cm no. 24
Suppy and apply metal door
8.41 Type MD02 Size (180x240) cm no. 4
8.42 Type MD04 Size (140x140) cm no. 1
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 8 - P2 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Contu. Division 08 Doors and Windows
Supply and apply glazed window
8.43 Type GW01 Size (171.5x465) cm no. 2
8.44 Type GW02 Size (245.8x100) cm no. 1
8.45 Type GW02A Size (182x100) cm no. 1
8.46 Type GW03 Size (925x180) cm no. 1
8.47 Type GW03A Size (929.5x280) cm no. 1
8.48 Type GW04 Size (189x210) cm no. 6
8.49 Type GW05 Size (195x50) cm no. 6
8.50 Type GW06 Size (195x210) cm no. 6
8.51 Type GW07 Size (240x50) cm no. 6
8.52 Type GW08 Size (240x240) cm no. 1
8.53 Type GW10 Size (340x60) cm no. 1
8.54 Type GW11 Size (160x300) cm no. 2
8.55 Type GW16 Size (660x380) cm no. 1
Aluminum windows, electro-static powder coated "Schuco International" sections including hardware Schuco double glazed with minimum 6mm thick e-coated reflective tinted glass outside and 6mm clear glass inside with heat mirror film HC75 in between Saint Gobain. Item will include all sealants, gaskets and the like as approved by engineer and manufacturer and as specified in the general specifications. All items include fly screens
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 8 - P3 Err:522
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountContu. Division 08 Doors and Windows
Suppy and apply curtain wall
8.56 Type CW01 Size (233.7x296.1) cm no. 1
8.57 Type CW02 Size (see curtain elevation) no. 1
8.58 Type CW03 Size (see curtain elevation) no. 4
8.59 Type CW04 Size (119x890) cm no. 1
8.60 Type CW05 Size (350x257.1) cm no. 1
8.61 Type CW06 Size (see curtain elevation) no 1
8.62 Type CW08 Size (195x346.5) cm no 1
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountTotal Amount of Division 8 - P4 0.00
Total Amount of Division 8 Err:522
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountDivision 09 - Finishes
Plaster.
For walls
9.1 CP-1 cement plaster m2 13250
9.2 CP-2 cement plaster with a smooth polished finish m2 11000
For ceilings
9.3 CP-1 cement plaster m2 4200
9.4 CP-2 cement plaster with a smooth polished finish m2 1300
9.5
m2 700
Ceramic Tiles
CT-1 Type A Ceramic Tiles
9.6 For floors m2 180
CT-2 Type B Ceramic Tiles
9.7 For floors m2 950
9.8 For skirting LM 1000
9.9 For walls m2 700
Mosaic Tiles
CT-3 Type A Mosaic Tiles
9.10 For floors m2 115
9.11 For walls m2 125
Supply and apply of cement plaster for internal works including all plaster accessories (plaster stopper, corner bead, lath, etc.)
Supply and apply of cement plaster for external works, facades and parapets, as specified on drawings, including joints, etc. Items includes all plaster accessories (plaster stopper, corner bead, lath, etc).
Supply and installation of ceramic tiles, colors and sized as per approved, including all requirements for installation, sand, cement, screed or adhesive and grouted.
Supply and installation fo Mosaic Tiles, colors and sized as per approved, including all requirements for installation, sand, cement, screed or adhesive and grouted
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 9 - P1 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountContu. Division 09 Finishes
Concrete Finish
9.12m2 3200
9.13 CSF-3: Concrete slab with smooth polished finish for floors m2 1950
9.14m2 320
9.15 CSF-5: Concrete slab with rough finish for floors LM 780
9.16
m2 4200
Marble
9.17 For floors m2 3800
9.18 For skirting LM 3300
9.19 For walls m2 3600
Stone
m2 1000
Wooden FinishSuppy and installation of wood flooring finish and painted
9.20 WD-1 m2 120
9.21 WD-2 m2 190
9.22 Suppy and installation of wood skirting and painted. WD-1 LM 4300
CSF-2: Concrete slab power float finish with solvent epoxy resin coating floors
CSF-4: Sand/cement screed with steel trowelled painted finish for floors
Suppy and apply of exposed concrete (color and finish for approval). ECC-1: Exposed concrete ceiling with smooth polished finish
Supply and installation of marble type MR-1 polished and final finished or as required as specified on details, and all requirements for installation, sand, cement screed or adhesive. Dimensions, types, and colors according to drawings and as per approval
Supply and installation of stone cladding for the facades and all requirements for installation, mechanically installed. Dimensions, types and colors according to drawings and as per approved samples
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 9 - P2 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountContu. Division 09 Finishes
Carpet
9.23 Supply and installation of carpet. CR-1: Type 1 carpet with underlay m2 4250
Ceiling Finish:
9.24 SC-1: 12.5mm thickness, decorative suspended gypsum board m2 2700
9.25LM 1130
9.26 SC-3: 600x600x12.5mm thickness, gypsum ceiling board m2 680
Painting
9.27 Type A Paint for CP-1 cement plaster wall m2 13250
9.28 Type A Paint for CP-1 cement plaster ceiling LM 4200
9.29m2 700
Metal Finish
9.30m2 2150
9.31
Sundries m2 420
Glass guardrail
9.32 Supply and apply of 12 cm height tempered glass guardrail LM 60
Supply and apply of suspended ceiling (color and finish as per approval)
SC-1: 12.5mm thickness, decorative moisture resistant suspended gypsum board
Supply and apply of internal painting, including all required coats according to specifications
Supply and apply of external painting including all required coats according to specifications
Supply and apply of aluminum composite cladding panels for the façades according to specifications
Supply and apply of powder coated aluminum composite louvers for the facades according to specifications
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountTotal Amount of Division 9 - P3 0.00
Total Amount of Division 9 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountDivision 10 Specialties
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 10 0.00
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total Amount
Total Amount of Division 2 - Site Constructions
Total Amount of Division 3 - Concrete Works
Total Amount of Division 4 - Masonry Works
Total Amount of Division 5 - Metal Works
Total Amount of Division 6 -Rough Carpentry
Total Amount of Division 8- Doors and Windows
Total Amount of Division 9 - Finishes
Total Amount of Division 10 - Specialties
Mobilization
Total Lump sum Price in AED
Total Amount of Division 7 -Thermal and waterproofing
Issue for Tender Rev (0)
DXB 06-13 Lotus HotelBOQ
Section 01200 - Part 2Page 15 of 37
Item Description Unit Qty Unit Price Total AmountTotal Lump sum Price in AED