bio mems persentation by prachi gadge from vnit (nit) nagpur

24
MT09MVD014 1 BIOMEMS MEMS for biomedical applications Guided by: Presented by: Prof. R. M. Patrikar Prachi Gadge MT09MVD014

Upload: vnitstudent

Post on 18-Nov-2014

113 views

Category:

Documents


2 download

DESCRIPTION

Bio Mems persentation by Prachi Gadge From VNIT (NIT) Nagpur under supervision of RM patrikar vnit Nagpur..Cordinator Madhuri Borkar

TRANSCRIPT

Page 1: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 1

BIOMEMS

MEMS for biomedical applications

Guided by: Presented by:Prof. R. M. Patrikar Prachi Gadge

MT09MVD014

Page 2: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 2

What is MEMS?? Micro-Electro-Mechanical Systems (MEMS) Also known as Micro Systems Technology (MST) MEMS are made up of components between 1 to 100 micrometres in size (i.e. 0.001 to 0.1 mm) Integration of mechanical elements, sensors,

actuators, and electronics on a common silicon substrate through microfabrication technology.

Page 3: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 3

Biomems

Biomedical or Biological Micro Electromechanical Systems.

These are MEMS for biomedical applications

Heavily researched area with a wide variety of important biomedical applications.

Page 4: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 4

Definition

‘‘Devices or systems, constructed using techniques inspired from micro/nano-scale fabrication, that are used for processing, delivery, manipulation, analysis, or construction of biological and chemical entities’’.

-Bashir, Purdue univ, 2004

Page 5: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 5

Challenges for using biomems

Biocompatibility : suitability with living system should be analysed.

Testing : real life testing can’t be done without permission of government authorities

Page 6: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 6

Biomems fabrication

Conventional IC processes and materials.

Additional processes and materials used in MEMS

Page 7: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 7

Conventional IC processes

Photolithography Thermal oxidation, dopant diffusion

ion implantation LPCVD, PECVD Evaporation, sputtering, wet etching, Plasma etching, reactive-ion etching, ion milling

Page 8: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 8

Conventional materials.

Silicon silicon dioxide silicon nitride aluminum

Page 9: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 9

Additional Fabrication Processes

Anisotropic wet etching of single-crystal silicon; deep reactive-ion etching or DRIE x-ray lithography Electroplating low-stress LPCVD films thick-film resist (SU-8) spin casting and micromolding batch microassembly

Page 10: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 10

Additional Materials

Piezoelectric films such as PZT; Magnetic films such as Ni, Fe, Co, and rare

earth alloys High temperature materials such as SiC and

ceramics; Mechanically robust aluminum alloys; stainless Steel; platinum; gold; sheet glass; Plastics such as PVC and PDMS

Page 11: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 11

MEMS Integration

The following methods are used to integrate multiple patterned materials together to fabricate a completed MEMS device:

1. Surface micromachining

2. Bulk micromachining

Page 12: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 12

Surface Micromachining

Page 13: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 13

Bulk Micromachining

Page 14: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 14

Biomedical Microsensors

The majority of MEMS used in biomedical

applications act as sensors:

– Microsensors for Biomechanics – Microsensors for Pneumatic Biosystems– Microsensors for Chemical Biosystems– Microsensors for Electrical Biosystems

Page 15: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 15

Biomedical Microactuators

Micromanipulators Surgical Microinstruments Micropumps Microneedles Microvalves Microfilters

Page 16: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 16

Micromanipulators

Page 17: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 17

Surgical Microinstruments

Page 18: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 18

Microneedles

Page 19: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 19

Microvalves

Page 20: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 20

Micropumps

Page 21: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 21

Microfilters

Page 22: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

MT09MVD014 22

Future Directions

Integrated device for analysis of single cells.

Building cell by cell/tissue engineering using micro and nano fabrication techniques

Integrated diagnostics and therapeutics (drug delivery)

Tools for genetic manipulation of microorganisms and viruses – synthetic biology

Page 23: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

Thank you!!

Page 24: Bio Mems persentation by Prachi Gadge  From VNIT (NIT) Nagpur

Questions???