BattenLok® HSTechnical/insTallaTion informaTion

Page 2: BattenLok HS - Metl-Span

IMPORTANT NOTICEREAD THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE BattenLok® HS ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE WARRANTIES WILL BE ISSUED.

ALWAYS INSPECT EACH AND EvERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEvER INSTALL ANY PRODUCT IF ITS qUALITY IS IN qUESTION. NOTIFY METL-SPAN IMMEDIATELY IF ANY PRODUCT IS BELIEvED TO BE OUT OF TOLERANCE, SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPMENT.

IF THERE IS A CONFLICT BETWEEN PROJECT INSTALLATION DRAWINGS PROvIDED OR APPROvED BY THE MANUFACTURER AND DETAILS IN THIS MANUAL, PROJECT INSTALLATION DRAWINGS WILL TAKE PRECEDENCE.

Ice Dam DisclaimerMetl-Span designs it’s standing seam roofs to meet the load requirements dictated by governing codes and project specifications, including applicable snow loads. However, Metl-Span expressly disclaims responsibilty for weathertightness or roof point loading issues or other hazards resulting from ice dam situations. Any time ice and snow can melt on the main body of the roof and refreeze at the eave or in the shadow of an adjacent wall, an ice dam situation may develop. In addition to local climate, ice dam formation is affected by many other factors, including but not limited to, roof insulation R value, roof panel color, interior temperature of building, heater location in building, eave overhangs, parapet walls, shading of building roof areas from adjacent trees, parapets, buildings, etc. These factors are design and maintenance issues and are outside the control of Metl-Span. Metl-Span specifically disclaims any liability for damage due to ice dam formation, although the following issues should be taken into consideration concerning standing seam roofs installed in freezing climates:

• Alwaysusefieldseamedpanels.Thesemachine-foldedseamsaremoredurablewhensubjectedtooccasionalicing.

• Eliminate “cold”eaveoverhangsandparapetwalls from thebuildingdesign.Roofoverhangsoutside theheatedenvelope of the building will tend to be colder than the roof areas over the heated envelope. Simple roof designsare preferred. Parapet walls at the eave allow ice and snow to collect due to shading effects and the lower rooftemperatures caused thereby.

• Make sure the interior of thebuilding is adequately insulatedand theheating is properly distributed. Inadequateinsulation in the roof and/or improper heat distribution causes heat flow though the main body of the roof. On dayswhen the temperature is below freezing, this heat gain can cause ice and snow to melt and refreeze at the eavewhere the roof is colder.

• Layoutthebuildingtopreventtheeavesandotherroofareasfrombeingshadedduringthewinter.Thismaymeaneliminating adjacent trees or reconsidering roof geometries.

• Considerusingself-regulatingheatingcablesattheeavestomitigatetheeffectsoficedams.

• Onbuildingdesignsusingattics,over-insulatetheatticfloorandprovideadequateventilationintheattic.Thiswillreduce heat transfer through the roof resulting in more consistent roof temperatures between eave and field of roof.

• Increasethedegreeofdiligencewithrespecttounderlaymentmaterialsatroofareaspronetoicing.Thismayincludevalleys, eaves, dormers and roof areas near dormers, parapets and the like where shading may occur.

Formoreinformationonthissubject,pleaserefertotheMCA’sMetalRoofDesignForColdClimatesmanual.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professionalhaveacopyofthemostcurrentversionoftheNorthAmericanSpecificationfortheDesignofCold-FormedSteelStructuralMemberspublishedby the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In acontinuing effort to refine and improve products, Metl-Span reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at metlspan.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence.

© 2019 Metl-Span, part of the Cornerstone Building Brands family. All Rights Reserved. Metl-Span’sSingleSkinproductlineismanufacturedbyMBCI.

Page 3: BattenLok HS - Metl-Span

TABLE OF CONTENTSBattenLok® HS

ROOFING SYSTEMGeneralDescription .......................................................................................................................................................... BHS-3Architect/EngineeringInformation ..................................................................................................................................... BHS-4

ENGINEERINGRead This First ................................................................................................................................................................. BHS-5UL90Requirements ......................................................................................................................................................... BHS-612"Properties/LoadTables .................................................................................................................................BHS-7–BHS-816"Properties/LoadTables ...............................................................................................................................BHS-9–BHS-10

GENERAL INFORMATIONProductChecklist ............................................................................................................................................BHS-11–BHS-20Panel Orientation ............................................................................................................................................................ BHS-21InstallationGuidelines ..................................................................................................................................................... BHS-21Preparatory Requirements .............................................................................................................................................. BHS-22Unloading ........................................................................................................................................................BHS-23–BHS-24Handling/Panel Storage .................................................................................................................................................. BHS-25ProperHandling,StorageandMaintenanceofPaintedandGalvalumePlus® Panels ..................................BHS-26–BHS-27

INSTALLATION SEqUENCEStep 1— RakeAttachments .................................................................................................................................... BHS-28Step 2— LowSystemEave ..................................................................................................................................... BHS-29Step 2A— HighSystemEave .................................................................................................................................... BHS-30Step 3— ThermalSpacer(ForHighSystemsOnly) ............................................................................................... BHS-31Step 4— FirstPanel ................................................................................................................................................ BHS-32Step 5— ClipInstallation ......................................................................................................................................... BHS-33Step 6— Endlap....................................................................................................................................................... BHS-34Step 7— Ridge ........................................................................................................................................................ BHS-35Step 8— SubsequentRunsEave ............................................................................................................................ BHS-36Step 9— SubsequentRunsEndlap ......................................................................................................................... BHS-37Step 10— SubsequentRunsRidge........................................................................................................................... BHS-38Step 11— LastPanelRun ......................................................................................................................................... BHS-39Step 12— SeamingOperation ...................................................................................................................BHS-40–BHS-41Step 13— OutsideClosureInstallation...................................................................................................................... BHS-42

SPECIAL ERECTION TECHNIqUESUL90LightTransmittingPanelInstallation .................................................................................................................... BHS-43RivetedRailLightTransmittingPanelInstallation ..........................................................................................BHS-44–BHS-47CurbInstallation ..............................................................................................................................................BHS-48–BHS-64Pipe Penetration Installation ...........................................................................................................................BHS-65–BHS-66

DETAILSOpen Framing FixedEaveWithHangOnGutter ................................................................................................................................... BHS-67FixedEaveWithEaveTrim ............................................................................................................................................ BHS-68Floating Ridge ................................................................................................................................................................. BHS-69 FixedVentedEave.......................................................................................................................................................... BHS-70 Rake................................................................................................................................................................................ BHS-71 RakeWithCleat .............................................................................................................................................................. BHS-72Parapet Rake .................................................................................................................................................................. BHS-73FloatingHighSideEave ................................................................................................................................................. BHS-74 ParapetFloatingHighSideEave ................................................................................................................................... BHS-75 Fixed Valley ................................................................................................................................. BHS-76 Floating Hip .................................................................................................................................................................... BHS-77

Page 4: BattenLok HS - Metl-Span

TABLE OF CONTENTSBattenLok® HS

Wood Deck FieldHemmingPanelEnd .............................................................................................................................................. BHS-78 Endlap .......................................................................................................................................... BHS-79 FloatingEavewithGutter ............................................................................................................................................... BHS-80 FloatingEavewithEaveTrim ......................................................................................................................................... BHS-81 Fixed Ridge ................................................................................................................................... BHS-82 Fixed Vented Ridge ........................................................................................................................................................ BHS-83 Rake ............................................................................................................................................ BHS-84 Parapet Rake .................................................................................................................................................................. BHS-85FixedHighSideEave ..................................................................................................................................................... BHS-86 ParapetFixedHighSideEave ....................................................................................................................................... BHS-87Floating Valley ................................................................................................................................................................ BHS-88 Fixed Hip ......................................................................................................................................................................... BHS-89

Rigid Insulation Over Metal Deck Endlap .............................................................................................................................................................................BHS-90 FloatingEaveWithGutter .............................................................................................................................................. BHS-91 FloatingEaveWithEaveTrimwithExtendedDripEdge ............................................................................................... BHS-92 Fixed Ridge ................................................................................................................................... BHS-93 Fixed Vented Ridge ........................................................................................................................................................ BHS-94 BoxRake ...................................................................................................................................... BHS-95Parapet Rake .................................................................................................................................................................. BHS-96 FixedBoxHighSideEave .............................................................................................................................................. BHS-97 ParapetFixedHighSideEave ....................................................................................................................................... BHS-98Floating Valley ................................................................................................................................................................ BHS-99 Fixed Hip .....................................................................................................................................BHS-100

Page 5: BattenLok HS - Metl-Span

ROOFING SYSTEM

SUBJECTTOCHANGEWITHOUTNOTICE SEEmetlspan.comFORCURRENTINFORMATION REV01.01BHS-3

BattenLok® HS

GENERAL DESCRIPTION

CoverageWidth-16"or12"

MinimumSlope-1/2:12

PanelAttachment-Low,High(FixedorFloating)orUtility(Noinsulationclearance)

PanelSubstrate-Galvalume®(standard)

Gauge-Standard:24;Optional:22

Finishes-SmoothStriated(standard)*orEmbossedStriatedandSmoothorEmbossedStriatedwithPencilRibs

Coatings-Signature®200,Signature®300,Signature®300Metallic

PRODUCT SELECTION CHART

Signatureisaregisteredtrademarkofthe Cornerstone Building Brands family.GalvalumePlusisaregisteredtrademarkofBIECInternational.

l —Availableinanyquantity.n—Minimumquantitymayberequired.

Othercolors,finishes,gauges,andmaterialsavailable;pleaseinquire.* Striatedpanelsarestandardtoreduce“oilcanning”.

2"

16" or 12"

With Striations

Signature®300Metallic

Signature®300 Signature®200 GalvalumePlus®

24Ga.

24Ga.

24Ga.

24Ga.

22Ga.

22Ga.

22Ga.

22Ga.PRODUCT

n n n ln n n n

n n n ln n n n

BattenLok® HS

16"Wide12"Wide

CAUTIONDiaphragm capabilities and purlin stability are not provided by manufactures BattenLok® HS roof system.

Therefore, other bracing may be required to conform to A.I.S.C. or A.I.S.I. specifications.

Page 6: BattenLok HS - Metl-Span

ROOFING SYSTEM

BHS-4REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CAUTIONApplication and design details are for illustration purposes only, and may not be appropriate for all environmental conditions or building designs. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices.

ARCHITECT/ENGINEER INFORMATION1. BattenLok® HS is a mechanically seamed roof system. BattenLok® HSpanelsareavailablein12"and16"widths.

Factory applied mastic inside of female leg of panel is standard.

2. BattenLok® HS is a structural roofing panel. This panel can be installed directly over purlins or bar joists. It does not require a solid substructure for support. The BattenLok® HS roofsystemhasseveraldifferentUL90constructionnumbers.

3. BattenLok® HS is recommended for roof slopes of ¹⁄₂:12orgreater.

4. Weathertight and aesthetically pleasing endlapsmay be accomplished through the use of swaged and prepunchedpanels. 12" wide panels are not prepunched for endlaps. The manufacturer provides a prepunched back-up plate at the endlap for weathertightness. Swaged endlaps require the roof erection to proceed from right to left as viewed from theeavelookingtowardtheridge.Roofswithnoendlapsandlessthan6:12maybeerectedfromeitherdirection.

5. Heaviergauges,striationsandembossingandinstallationoverasoliddeckminimizeoilcanning.Industrystandardisaminimum24gaugematerial.Striationsarestandardtoreduceoilcanning.Oilcanningisnotacauseforrejection. Panels are available with the option of striated with pencil ribs.

6. Substructuremustbeonanevenplanefromeavetoridgetoavoidpaneldistortion(¹⁄₄"in20',³⁄₈"in40'tolerance).

7. Allpanelsrequireendsealantateaveandvalleyconditions;however,forillustrationpurposes,thissealantisnotshownon all drawings.

8. Forproperfastenerapplication,seeProductChecklist.

9. Allperimetertrimdimensionsinthismanualarebasedonawallpanelthicknessof1¹⁄₄"("PBR"Panel).Anyvariationfrom this wall panel thickness may affect the perimeter trim dimensions.

10.Theinformationinthismanualisbelievedtobecorrectandaccurate.

11. Drawingsinthismanualutilizethelowfloatingclip.Clipsareavailableinloworhighfixed,loworhighfloatingandutility.

12. Avoid restricting the thermal expansion and contraction of the BattenLok® HS panels. (ie: Do not attach panel to the substructure at both the eave and ridge.) However, panels must be attached to the substructure at one end to prevent their sliding downslope.

13. BattenLok® HS panels are not designed to be work platforms. Avoid any unnecessary foot traffic on BattenLok® HS panels. If foot traffic is required, protect the roof panels by using soft soled shoes and some type of roof pad, temporary deck, or walkway.

14. WARNING: Light transmitting panels are not designed or intended to bear the weight of any person walking, stepping, standing or resting on them. THE MANUFACTURER DISCLAIMS ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, that any person can safely walk, step, stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation.

15. Avaporretardermaybenecessarytoprotectroofingcomponentswhenhighinteriorhumidityisafactor.Theneedfora vapor retarder, as well as the type, placement and location should be determined by an architect or engineer. The followingareexamplesofconditionsthatmayrequireavaporretarder:(A)Projectswhereoutsidewintertemperaturesbelow40°Fareanticipatedandwhereaveragewinterinteriorrelativehumidityof45%orgreaterisexpected.(B)Buildingusages with high humidity interiors, such as indoor swimming pools, textile manufacturing operations, food, paper or otherwet-processindustrialplants.(C)Constructionelementsthatmayreleasemoistureaftertheroofisinstalled,suchas interior concrete and masonry, plaster finishes and fuel burning heaters.

16. Typically,whenwooddecksareused,theyaretemporarilyprotectedbytheinstallationofamoisturebarrieroverthewood deck. If utility clips are to be used, the BattenLok® HS panel will lay tight to the wood deck. If tin tabs are used to attach the moisture barrier to the deck, they must be covered with duct tape or some other material to prevent them fromrustingthebacksideofthepanels.Also,plasticwashersmay“telegraph”throughthepanels.

17. Fieldcuttingof thepanelsshouldbeavoidedwherepossible. If fieldcutting is required, thepanelsmustbecutwithnibblers, snips, or shears to prevent edge rusting. Do not cut the panels with abrasive saw blades, grinders, or torches.

Page 7: BattenLok HS - Metl-Span

ENGINEERING

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-5

BattenLok® HS

Low Floating System-Withorwithout³⁄₈"thermalspacer.See Insulation/Thermal Spacer Selection Chart below.

High Floating System-With³⁄₈",⁵⁄₈"or1"thermalspacer.See Insulation/Thermal Spacer Selection Chart below.

Thermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating clip’s capacity. various densities of blanket insulation may affect the installation and or the appearance of a metal roof system. The installer is responsible for selecting the proper clip and thermal spacer for their conditions.

CAUTIONThe use of any field seaming machine other than that provided by the manufacturer will damage the panels and void all warranties and will void all engineering data.

IMPORTANTREAD THIS FIRST

Insulation/Thermal Spacer Selection Chart Insulation Thickness Low System High System No Insulation ³⁄₈"ThermalSpacer HighSystemNotRecommended 3"Insulation ThermalSpacerNotRecommended ⁵⁄₈"ThermalSpacerRecommended 4"Insulation ThermalSpacerNotRecommended ³⁄₈"ThermalSpacerRecommended 6"Insulation LowSystemNotRecommended ThermalSpacerNotRecommended

Thermal Spacer DisclaimerTheabovethermalspacerchartisintendedtobeusedasageneralguidelineonly.Becauseofthevariousdensitiesofinsulationcurrently available, the manufacturer cannot guarantee that this chart will be accurate in all situations. Further, the manufacturer does not specifically require that the roofing contractor use thermal spacers with it’s BattenLok® HS roof system. However, please review the following information:• Although the manufacturer does not require a thermal spacer, the architect or building owner may.• In certain environments, the compression of the fiberglass insulation, without a thermal spacer, may create a

thermal break which can cause condensation to form on the purlins/joists.• Onuninsulatedbuildings,eliminatingthethermalspacer:(1)maycause“roofrumble”and(2)youmayencounter

problems holding panel module.• Whenahighclipisusedwithoutathermalspacer:(1)youmayencounterproblemsholdingpanelmoduleand(2)

foot traffic on the panel ribs may result in bent clips.• Usingalowclipwithtoomuchinsulationortoothickofathermalspacer:(1)maycause“purlinread”(2)maycausedifficultyinproperlyinstallingthepanelsidelaps,and(3)youmayencounterproblemsholdingpanelmodule.

WarningAswithall standingseamroofsystems,soundattenuation (example: blanket insulation)shouldbe installedbetween thepanelsandopenframing,suchaspurlinsorjoists,toprevent“roofrumble”duringwindyconditions.

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior. This is especially important if the bottom of the deck is left open to the interior, in cathedral ceiling applications or when the attic space is used as a return air plenum.

A vapor retarder may be necessary to protect roofing components when high humidity is a factor. The need for a vapor retarder, as well as the type, placement and location should be determined by an architect or engineer. The following are examplesofconditionsthatmayrequireavaporretarder:(A)aprojectwhereoutsidewintertemperaturesbelow40degreesF.areanticipatedandwhereaveragewinterinteriorrelativehumidityof45%orgreaterisexpected.(B)buildingusageswithhigh humidity interiors such as indoor swimming pools, textile manufacturing operations, food, paper or other wet-process industrialplants.(C)Constructionelementsthatmayreleasemoistureaftertheroof is installed,suchasinteriorconcrete,masonry or plaster work and fuel burning heaters.

Page 8: BattenLok HS - Metl-Span

ENGINEERING

BHS-6REV01.01 SEEmetlspan.comFORCURRENTINFORMATION SUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

UL-2218 Construction Panel Clip Impact UL-263 UL-580

Number Width (In.) Gauge Clip Type Spacing Substrate Resistance Fire Rating Rating

90 16" 24min. * 5'-0¹⁄₁₆" OpenFraming Class4 ClassA Class90

176 16" 24min. N/A 5'-0¹⁄₄" OpenFraming Class4 ClassA Class90

180 16" 24min. ** 5'-0¹⁄₄" OpenFraming Class4 ClassA Class90

238B 16" 24min. ** 2'-6" CompositeSystem Class4 ClassA Class90

437 16" 24min. ** 5'-0" Plywood Class4 ClassA Class90

449 16" 24min. * 5'-0" OpenFraming Class4 ClassA Class90

451 16" 24min. * 2'-0" CompositeSystem Class4 ClassA Class90

452 16" 24min. * 2'-0" CompositeSystem Class4 ClassA Class90

487 16" 24min. ** 4'-0" CompositeSystem Class4 ClassA Class90

UNDERWRITERS LABORATORIES APPROvALBattenLok® HS

* FixedorFloating(highorlow)** FixedorFloating(high,low,orutility)

NOTES:1. TestsproceduresareinaccordancewithUnderwritersLaboratoriesStandardUL-580under“TestsForUpliftResistance

ofRoofAssemblies”.2. AdetailedinstallationmethodisavailableforeachConstructionNumberaboveandcanbefoundintheULRoofing

MaterialsandSystemsDirectory.Thepanelsmustbeinstalledinacertainmannertoachievethepublishedresults.3. ThepanelqualifiesforaClassAfireratingincompliancewithUnderwritersLaboratoriesStandardUL-263wheninstalled

overanon-combustiblesubstrate.AClassCfireratingcanbeobtainedoveracombustibledeck.4. ThepanelsystemqualifiesunderthefollowingFireResistanceDesignNumbers:P225,P227,P230,P237,P265,P268,

P508,P510,P512,P701,P711,P720,P722,P726,P731,P734,P801,P815,andP819.RefertotheULFireResistanceDirectoryforspecificconstructionmethodsandhourlyratings.

5. BattenLok® HSpanelscarryaClass4ratingunderUL-2218“TestStandardForImpactResistance”.

BattenLok®isaregisteredtrademarkofCornerstone Building Brands family,L.P. Galvalume®isaregisteredtrademarkofBIECInternational,Inc. vise-Grip®isaregisteredtrademarkofAmericanToolCompanies,Inc.

Page 9: BattenLok HS - Metl-Span

ENGINEERING

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-7

BattenLok® HS

BattenLok® HS Panel

2"

12"

SECTION PROPERTIESNEGATIvE BENDING POSITIvE BENDING

PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo

GAUGE (KSI) (PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.)

24 50 1.41 0.0836 0.0749 2.2421 0.1851 0.1165 3.4864

22 50 1.81 0.1157 0.1077 3.2247 0.2430 0.1536 4.6008

NOTES:1.AllcalculationsforthepropertiesofBattenLok® HSpanelsarecalculatedinaccordancewiththe2012editionoftheNorthAmericanSpecificationForDesignOfCold-FormedSteelStructuralMembers.2.Ixeisfordeflectiondetermination.3.Sxeisforbending.4.Maxoisallowablebendingmoment.5.Allvaluesareforonefootofpanelwidth.

TheEngineeringdatacontainedhereinisfortheexpresseduseofcustomersanddesignprofessionals.Alongwiththisdata,itisrecommendedthatthedesignprofessionalhaveacopyofthemostcurrentversionoftheNorthAmericanSpecificationfortheDesignofCold-FormedSteelStructuralMemberspublishedbytheAmericanIronandSteelInstitutetofacilitatedesign.ThisSpecificationcontainsthedesigncriteriaforcold-formedsteelcomponents.AlongwiththeSpecification,thedesignershouldreferencethemostcurrentbuildingcodeapplicabletotheprojectjobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

Page 10: BattenLok HS - Metl-Span

ENGINEERING

BHS-8REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

ALLOWABLE UNIFORM LOADS IN POUNDS PER SqUARE FOOT

BattenLok® HS

2"

12"

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5SINGLE LIvE 216.0 180.0 154.3 145.3 114.8 93.0 76.8

2-SPAN LIvE 216.0 166.1 122.0 93.4 73.8 59.8 49.4

3-SPAN LIvE 216.0 180.0 152.5 116.8 92.3 74.7 61.8

4-SPAN LIvE 216.0 180.0 142.4 109.0 86.2 69.8 57.7

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5SINGLE LIvE 311.2 259.5 237.3 191.7 151.5 122.7 101.4

2-SPAN LIvE 311.2 238.9 175.5 134.4 106.2 86.0 71.1

3-SPAN LIvE 311.2 259.5 219.4 168.0 132.7 107.5 88.8

4-SPAN LIvE 311.2 259.5 204.8 156.8 123.9 100.4 82.9

NOTES:

1. THE ABOvE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.2.Strengthcalculationsbasedonthe2012AISIStandard“NorthAmericanSpecificationfortheDesignofCold-formedSteelStructuralMembers.”

3.Allowableloadsareapplicableforuniformloadingandspanswithoutoverhangs.

4.LIVEloadcapacitiesareforthoseloadsthatpushthepanelagainstitssupports.Theapplicablelimitstatesareflexure,shear,combinedshearandflexure,webcripplingatendandinteriorsupports,andadeflectionlimitofL/180understrength-levelloads.

5.PanelpulloverandScrewpulloutcapacitymustbecheckedseparatelyusingthescrewsemployedforeachparticularapplicationwhen utilizing this load chart.

6.Theuseofanyfieldseamingequipmentoraccessoriesincludingbutnotlimitedtoclips,fasteners,andsupportplates(eave,backup,rake,etc.)otherthanthatprovidedbythemanufacturermaydamagepanels,voidallwarrantiesandwillvoidallengineeringdata.

7.Thismaterialissubjecttochangewithoutnotice.PleasecontactMetl-Spanforthemostcurrentdata.

TheEngineeringdatacontainedhereinisfortheexpresseduseofcustomersanddesignprofessionals.Alongwiththisdata,itisrecommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural MemberspublishedbytheAmericanIronandSteelInstitutetofacilitatedesign.ThisSpecificationcontainsthedesigncriteriaforcold-formedsteelcomponents.AlongwiththeSpecification,thedesignershouldreferencethemostcurrentbuildingcodeapplicableto the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

Page 11: BattenLok HS - Metl-Span

ENGINEERING

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-9

BattenLok® HS

BattenLok® HS

2"

16"

With Striations

2"

16"

Striated with Pencil Ribs

SECTION PROPERTIESNEGATIvE BENDING POSITIvE BENDING

PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo

GAUGE (KSI) (PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.)

24 50 1.38 0.0574 0.0538 1.6096 0.1324 0.0779 2.3324

22 50 1.72 0.0794 0.0776 2.325 0.1779 0.1057 3.1654

NOTES:1.AllcalculationsforthepropertiesofBattenLok® HSpanelsarecalculatedinaccordancewiththe2012editionoftheNorthAmericanSpecificationForDesignOfCold-FormedSteelStructuralMembers.2.Ixeisfordeflectiondetermination.3.Sxeisforbending.4.Maxoisallowablebendingmoment.5.Allvaluesareforonefootofpanelwidth.

TheEngineeringdatacontainedhereinisfortheexpresseduseofcustomersanddesignprofessionals.Alongwiththisdata,itisrecommendedthatthedesignprofessionalhaveacopyofthemostcurrentversionoftheNorthAmericanSpecificationfortheDesignofCold-FormedSteelStructuralMemberspublishedbytheAmericanIronandSteelInstitutetofacilitatedesign.ThisSpecificationcontainsthedesigncriteriaforcold-formedsteelcomponents.AlongwiththeSpecification,thedesignershouldreferencethemostcurrentbuildingcodeapplicableto the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

Page 12: BattenLok HS - Metl-Span

ENGINEERING

BHS-10REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

ALLOWABLE UNIFORM LOADS IN POUNDS PER SqUARE FOOT

BattenLok® HS

2"

16"

With Striations

2"

16"

Striated with Pencil Ribs

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5SINGLE LIvE 162.0 135.0 115.7 112.6 88.9 72.0 59.5

2-SPAN LIvE 162.0 126.9 93.3 71.4 56.4 45.7 37.8

3-SPAN LIvE 162.0 135.0 115.7 89.3 70.5 57.1 47.2

4-SPAN LIvE 162.0 135.0 108.8 83.3 65.8 53.3 44.1

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5SINGLE LIvE 233.4 194.5 166.7 151.3 119.5 96.8 80.0

2-SPAN LIvE 233.4 182.7 134.3 102.8 81.2 65.8 54.4

3-SPAN LIvE 233.4 194.5 166.7 128.5 101.5 82.2 68.0

4-SPAN LIvE 233.4 194.5 156.7 120.0 94.8 76.8 63.5

NOTES:1. THE ABOvE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.2.Strengthcalculationsbasedonthe2012AISIStandard“NorthAmericanSpecificationfortheDesignofCold-formedSteelStructuralMembers.”3.Allowableloadsareapplicableforuniformloadingandspanswithoutoverhangs.4.LIVEloadcapacitiesareforthoseloadsthatpushthepanelagainstitssupports.Theapplicablelimitstatesareflexure,shear,combinedshearandflexure,webcripplingatendandinteriorsupports,andadeflectionlimitofL/180understrength-levelloads.

5.PanelpulloverandScrewpulloutcapacitymustbecheckedseparatelyusingthescrewsemployedforeachparticularapplicationwhenutilizingthis load chart.

6.Theuseofanyfieldseamingequipmentoraccessoriesincludingbutnotlimitedtoclips,fasteners,andsupportplatesotherthanthaprovidedbythemanufacturermay(eave,backup,rake,etc.)damagepanels,voidallwarrantiesandwillvoidallengineeringdata.

7.Thismaterialissubjecttochangewithoutnotice.PleasecontactMetl-Spanforthemostcurrentdata.

TheEngineeringdatacontainedhereinisfortheexpresseduseofcustomersanddesignprofessionals.Alongwiththisdata,itisrecommendedthat the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural MemberspublishedbytheAmericanIronandSteelInstitutetofacilitatedesign.ThisSpecificationcontainsthedesigncriteriaforcold-formedsteelcomponents.AlongwiththeSpecification,thedesignershouldreferencethemostcurrentbuildingcodeapplicabletotheprojectjobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

Page 13: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-11

BattenLok® HS

HW-224q

•High–Forusewith ³⁄₈",⁵⁄₈"or1"thermal spacer

2"

3 ⁷⁄₈"

2"

16" or 12"

With Striations

2"

16"

Striated with Pencil Ribs

BattenLok® HS Panel

Back-Up Plate •Foruseatridgeandendlaps

•Prepunched•16gaugeredoxide

2 ³⁄₈"

3"

LOW

HIGH

2 ³⁄₈"

3"

LOW

HIGH

•Low–Forusewith or without ³⁄₈"thermal spacer.

•Low–Forusewith or without ³⁄₈"thermal spacer.

•Recommendedforuse when clips are attached directly to bar joists.

•High–Forusewith ³⁄₈",⁵⁄₈"or1"thermal spacer.

•High–Forusewith ³⁄₈",⁵⁄₈"or1"thermal spacer.

2 ³⁄₈"

3 ¹⁄₂"3"

2 ⁷⁄₈"

LOW

HIGH

Rake Support •20'-0"length•14gaugeredoxide•Factoryslots•Forusewithlowor

high clip

•20'-0"length•14gaugeredoxide•Factoryslots•Forusewithutilityclip

Rake Support Utility

5"

3 ⁷⁄₈"

•16gaugeredoxide•Forusewithlowor

utility systems•Forusewithrigid

board insulation

Bearing PlateStandard

•Low–Forusewith or without ³⁄₈"thermal spacer

HW-226q

2 ³⁄₈"

3"

LOW

HIGH

Clip, Fixed

HW-218q

Clip, Utility

2"

•Forapplicationsthatdo not require the clearance provided by the low and high clips.

Clip, Floating

Clip, Floating (Optional)

16"q

HW-220q

HW-240q

HW-222q

HW-242q

12"q16"q

16"WideHW-7766q12"WideHW-7764q

PRODUCT CHECKLIST

HW-7500q

HW-7732q

HW-7712-LowqHW-7722-Highq

Page 14: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-12REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

1¹⁄₂"

5⁷⁄₁₆"

1"

Floating Eave Plate, High

1⁹⁄₁₆"

³⁄₈"

¹⁵⁄₁₆"

1¹⁄₂"

³⁄₈"

1¹⁄₂"

4¹⁄₂"¹⁵⁄₁₆"

•8'-0"length•14gauge•RedOxide

1"

1 ¹⁄₂"

1 ¹⁄₂"

•8'-0"length•14gauge•RedOxide

4 ¹⁄₁₆"

³⁄₈"

1 ⁷⁄₈"1"

Eave Plate, Low

Floating Eave Plate, Low •8'-0"length•14gauge•RedOxide

Mid-Slope Fixed Plate, Low

Eave Plate, High

•8'-0"length•14gauge•RedOxide

Mid-Slope Fixed Plate, High

4 ¹⁄₁₆"

1"

2 ⁵⁄₁₆"1 ⁹⁄₁₆"

•14gauge•RedOxide

•14gauge•RedOxide

PRODUCT CHECKLIST

HW-7630(10’-0”Long)qHW-7631(10’-0”Long)qHW-7632(6’-0”Long)q

HW-7637(6’-0”Long)qHW-7631(10’-0”Long)qHW-7632(20’-0”Long)q

HW-7600q HW-7616q

HW-7617q HW-7618q

Page 15: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-13

BattenLok® HS

Ridge/Hip Support Plate–HighFixedSystems

7 " 9⁹⁄₁₆"

SPECIFY ANGLE

135°

1³⁄₈" 135°

Ridge/Hip Support Plate–LowFixedSystems

7" 9³⁄₄"

SPECIFY ANGLE 1¹⁄₄" 163°

163°

PRODUCT CHECKLIST

valley Support Plate–LoworUtilitySystems

15"

SPECIFY ANGLE

15"

SPECIFY ANGLE

•UseOverRigidInsulation•StandardWidth

14"

1" 90°

10'-0"LongP-106q

10'-0"LongP-105q

10'-0"LongP-141q

10'-0"LongP-145q 10'-0"LongP-155q

10'-0"LongP-140q

10'-0"LongP-100q

10'-0"LongP-162q10'-0"LongP-164q

valley Support Plate–LoworUtilitySystems

•UseOverPurlins/Joists•StandardWidth

valley Support Plate–LoworUtilitySystems

18"

SPECIFY ANGLE

•ExtendedWidth•UseOverRigidInsulation

17"

SPECIFY ANGLE

1" 90°

Extended valley Support Plate–LoworUtilitySystems

•ExtendedWidth•UseOverPurlins/Joists

21"

SPECIFY ANGLE

135°

1⁷⁄₁₆"

1⁹⁄₁₆"

135°

1"

valley Support Plate–HighSystems

•ExtendedWidth•UseOverPurlins/Joists

SPECIFY ANGLE

11 ¹¹⁄₁₆"

Hip Support Plate–LowFloatingSystems

•UseOverSolidSubstrate•UseOverPurlins/Joists

Hip Support Plate - HighorLowFloatingSystems

SPECIFY ANGLE

10¹¹⁄₁₆"

1"

valley Support Plate - High Systems

12"

SPECIFY ANGLE

135°

1⁷⁄₁₆"

1⁹⁄₁₆"

135°

1"

•StandardWidth•UseOverPurlins/Joists

•UsewithallSubstrates •UsewithallSubstrates

10'-0"LongP-101q

Page 16: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-14REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

Panel Hemming Tool

Light Transmitting Panel (Reinforced)‡

Outside Closure

16"wideHW-440q

Tape Sealer-Swaged

6"

3"

³⁄₈",⁵⁄₈", or 1"

15 ⁷⁄₈"

Thermal Spacer

qHW-5811"

qHW-583³⁄₈"qHW-582B⁄₈"

•Polystyreneblockused to increase the insulation capacity along the purlins

Tube Sealant

•³⁄₁₆"x⁷⁄₈"x25'•Foruseateave, ridge, endlaps and trim connections

•³⁄₁₆"x2B⁄B"x20'•Foruseatvalleywhen

using exposed fasteners•Forusewithroofcurbs

Tape Sealer

Urethane(Bronze)-HW-542qUrethane(Gray)-HW-541qUrethane(White)-HW-540q

•UL90Insulated-HW-1801HSBq•Std.Uninsulated-HW-1802HSBq•Std.Insulated-HW-1803HSBq

•UL90Uninsulated-HW-1800HSBq

•24gauge•Painted

12"wideHW-446q

PRODUCT CHECKLIST

‡It is the user’s responsibility to ensure that the installation and use of all light transmitting panels comply with State, Federal and OSHA regulations and laws, including, but not limited to, guarding all light transmitting panels with screens, fixed standard railings, or other acceptable safety controls that prevent fall-through.

Non-SkinningButyl-HW-549q

Triple Bead

Tri-Bead

HW-502q

HW-504q

HW-515q

HW-525q

HW-602q

Metal vent Material

Page 17: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-15

BattenLok® HS

PRODUCT CHECKLIST

q q

qq

PART NO.

ROOF PITCH

DIM.“A” NOTE

FL-200 BBB-3C\v:12 3BBB" For use without ventilator18" Peak purlin spacingFL-202 3BBBBB-6:12 4BBB"

FL-213 BBB-3C\v:12 6BBB" For use without ventilator24" Peak purlin spacingFL-214 3BBBBB-6:12 7BBB"

Ridge Flashing

2¹⁄₂"

1¹⁄₄"

"A"

120°

120 °

COLOR

FL-125 qLength-2'-1"Girth-33BBB"

•ForusewithFL-200,FL-202,FL-213,FL-214,FL-300,FL-302,FL-540 or FL-541 Ridge Flashing

FL-126 qLength-2'-6"Girth-37BBB"

•ForusewithFL-205,FL-207,FL-303,FL-304,FL-543orFL-544

Ridge Flashing

•IncludesCinchAnglesand Flexible Membrane•SpecifyRoofSlope

Floating Peak Box

qq

qq

Ridge Flashing forPerforated vent Drip "A"

2¹⁄₂"

COLOR1¹⁄₄"

1"

PART NO.

ROOF PITCH

DIM.“A”

NOTE

FL-300 BBB-3C\v:12 4BBB" For use with perforated ventdrip(FL-254)18" Peak purlin spacingFL-302 3BBBBB-6:12 5BBB"

FL-303 BBB-3C\v:12 7BBB" For use with perforated ventdrip(FL-254)24" Peak purlin spacing

FL-304 3BBBBB-6:12 8BBB"

q

q

q

PART NO.

ROOF PITCH

DIM.“A” NOTE

FL-209 BBB-3C\v:12 6" For use without vent material18" Peak purlin spacing

FL-211 3BBBBB-6:12 7"

FL-212 All Pitches 11BBB" For use without vent material24" Peak purlin spacing

Ridge/Hip Flashing - Fixed

"A"COLOR

Ridge End Cap

FL-201 q

•SpecifyRidgetobeusedand Roof Slope

1"

3¹⁄₄"1"

¹⁄₂"

1"

PERFORATED

•UsewithFL-300,FL-302,FL-303orFL-304RidgeFlashing

Perforated vent Drip

qFL-25424GaugeMaterial

COLOR

1"

"A"

1"

ZEE Closure

24GaugeMaterial qFL-361

•UseatHips

Sculptured High Side Eave Trim

COLOR135°

102°

⁵⁄₈"

102°

90° + ° ofROOF SLOPE

5¹⁄₂"

4³⁄₄"

4³⁄₄"

1³⁄₄"

"A"

PART NO. ROOFPITCH DIM.AFL-265 BBB-1BBB:12 2"FL-265B 1BBBBB-4:12 3BBBBB" q

q

•Specifyopenhem when using with continuous cleat

Page 18: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-16REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

SPECIFYANGLE

⁵⁄₈"3"

1¹⁄₂"

2¹⁄₂"

Eave with Extended Drip Edge

•UsewithRoofSlopesBBB-6:12•Specifyopenhemwhenusing

with continuous cleat

⁷⁄₈"

90°³⁄₄"

45°

⁵⁄₈"

COLOR

¹⁄₂"

24GaugeMaterial

SPECIFYANGLE

5"

10¹⁄₄"COLOR

⁵⁄₈"

Box High Side Eave Trim

FL-331qSpecify Roof Pitch

PRODUCT CHECKLISTSculptured Gutter - Standard

90° 1"

1"

156°

102°

90°-° ofROOF SLOPE

¹⁄₂"

4³⁄₄"

4³⁄₄"

4¹⁄₂"

102°

COLOR

90°+° ofROOF SLOPE

DIM"A"

q

qPART NO. ROOFPITCH DIM.“A” GIRTH

FL-248A BBB-4:12 7BBBB" 23BBBB"

FL-248B 4BBBB-6:12 7BBBBB" 24BBBB"

2"COLOR

156°

135°

90°102°

90°

1³⁄₄"

³⁄₄"3⁵⁄₈"

⁵⁄₈"

4³⁄₄"

4³⁄₄"

Sculptured Eave Trim

FL-253q

2"

COLOR

¹⁄₂"

⁵⁄₈"

90°

102°

135°

156°102°

90°-° ofROOF SLOPE

1³⁄₄"

4³⁄₄"

2⁵⁄₈"

2¹⁄₂"

Specify Roof Pitch

Sculptured Rake Trim

10"

Gutter Strap •ForusewithSculpturedGutter

18GaugeMaterial

Gutter EndsLeftorRight

•UsewithallSculpturedorStyleGutters•EndCapswillbemadetofit gutter ordered•Specifyleftorright•Specifygutterpartnumber

4"SPECIFYANGLE

COLOR

3¹⁄₂"

⁵⁄₈"

•Specifyopenhem when using with continuous cleat

³⁄₄"

9"

90°

COLOR

Rake Slide - High Wind

Box Eave Trim

variable Termination

FL-111q

T-5151q

FL-215q

FL-117q

FL-245q

FL-246q

FL-326q

Page 19: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-17

BattenLok® HS

•SpecifyRoofSlopeParapet High Side Eave Flashing - Fixed

6" COLOR

5¹⁄₂"

Parapet Rake Cleat - High Wind

⁵⁄₈"

5"

3"COLOR

Box Rake Trim

PRODUCT CHECKLIST

Parapet High Side Eave Flash -Floating

"A"COLOR

4³⁄₄"

1¹⁄₄"

2¹⁄₂"

PART NO. DIM.AFL-275 3BBB"FL-274 4BBB"

Parapet Rake Flash

"A"4"

1"

COLOR

OPENHEM

PART NO. DIM.AFL-285 3"FL-286 5"FL-287 7"

NOTE:Alltrimtobe26gaugematerialunlessnoted.Refertocurrentpricebookforpartnumbersanddescriptions.

q

q

qqq

Gutter EndsLeftorRight

•UsewithT-5271BoxGutterwithDripEdge•Specifyleftorright

Box Gutter with Drip Edge

1"

6"

SPECIFYANGLE

COLOR

5¹⁄₂"

5¹⁄₄"

4¹⁄₂"

1¹⁄₂"⁵⁄₈"

Specify Roof Pitch

10"

2"

Gutter Strap

24GaugeMaterial

•ForusewithBoxGutter

FL-306q FL-292q

FL-310qT-5271q

T-5291qFL-276q

1"

1"COLOR

³⁄₄"

³⁄₄"

Page 20: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-18REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

16 "

SPECIFY ANGLE

2"

45°

Standard valley - Utility, Low and High Systems Extended valley - Utility, Low and High Systems

24GaugeMaterial 24GaugeMaterial

3¹⁄₂"

4"¹⁄₂"

SPECIFYANGLE

Box Panel Cap Trim

Specify Roof Pitch

PRODUCT CHECKLIST

95°

2"SPECIFYANGLE

2¹⁄₂"

1¹⁄₈"1³⁄₈"

¹⁄₂"

Offset Panel Cap Trim

1¹⁄₂"

1¹⁄₂"

¹⁄₂"

¹⁄₈"

Offset Cleat

24GaugeMaterial

135°

2¹⁄₂"

¹⁄₂"

Continous Cleat

24GaugeMaterial

Counter Flash

90°

1"

30°

COLOR

2¹⁄₂"

¹⁄₂"

24GaugeMaterial

1"

150°

³⁄₄"

¹⁄₂"

⁵⁄₈"

⁵⁄₈"

COLOR

Alternate Counter Flash

24GaugeMaterial

2"

SPECIFY ANGLE

45°

11¹⁄₂"

FL-337q

FL-341q

FL-272q

FL-705q FL-711q

FL-271q

FL-343q

FL-338q

Page 21: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-19

BattenLok® HS

Fastener #1B

PRODUCT CHECKLISTFastener #1E •Paneltoeaveplateor

eave strut•Raketrimtoroofpanel•Standardendlaps•Paneltovalleyplate•Outsideclosuretopanel

with back-up plate or support plate

¹⁄₄"-14x1¹⁄₄"LongLifeSelfDriller⁵⁄₁₆"HexWasherHead,withsealingwasher

Fastener #2B •Endlapoverplywood

¹⁄₄"-14x1"LongLifeAB³⁄₈"HexWasherHead,withsealingwasher

Fastener #4

¹⁄₄"-14x⁷⁄₈"LongLifeLapTek® SelfDriller⁵⁄₁₆"HexWasherHead,withsealingwasher

•Ridgeandotherflashingto outside closure

•Guttertopanel•Guttertostrap•Trimtotrimconnections•Sculpturedeavetrimto

panel

Fastener #5

¹⁄₄"-14x1¹⁄₄"ShoulderTek®2SelfDriller⁵⁄₁₆"HexWasherHead,withnowasher

•Rakesupporttopurlin(FloatingSystemOnly)

•Floatingeaveplatetoeave strut

Fastener #55

12-24x1¹⁄₄"with#5DrillPoint⁵⁄₁₆"HexWasherHead,withnowasher

•Cliptopurlin(Upto4"insulation between panel andpurlin)

¹⁄₄"-14x1¹⁄₄"SelfDriller⁵⁄₁₆"HexWasherHeadwithnowasher

Fastener #142

Fastener #70

•Cliptopurlin(Over4"insulation between panel andpurlin)

•Cliptopurlin(Over4"insulation between panel andpurlin)

¹⁄₄"-14x1¹⁄₂"SelfDriller⁵⁄₁₆"HexHead,with⁵⁄₈"O.D.washer

12-14x1¹⁄₂"with#5DrillPoint⁵⁄₁₆"HexWasher,withnowasher

Fastener #2A •UseinplaceofFasteners#1E,#2Band#4atallstripouts

17x1"LongLifeAB⁵⁄₁₆"HexWasherHead,withsealingwasher

Fastener #11

¹⁄₄"x1¹⁄₄"NailDriveMasonryAnchor

• Special application fastener

• For attaching trim to masonary walls

q

q

q

q

q

q

q

q

q

•Cliptopurlin(Upto4"insulation between panel andpurlin)

Page 22: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-20REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

PRODUCT CHECKLISTFastener #13A •Offsetcleattoplywood

•Rakeangletoplywood•Cliptoplywood

12x1"#2Phillips/SquareDrivePancakeType“A”

Fastener #14A

Fastener #46

Fastener #14 Fastener #43L

Stainless Steel Pop Rivet ¹⁄₈"diameterx³⁄₁₆"griprange

•Trimtotrimconnections •UseatlowerendlapofLTP’s

Stainless Steel Pop Rivet ¹⁄₈"diameterx³⁄₈"griprange

•Outsideclosuretoangleon floating hip detail

•Panelclipstowooddeck•Outsideclosuretopanel

over wood deck

Fastener #1 •Eaveplatetoeavestrut•Mid-slopefixedplateto

purlin•Rakesupporttoangle(Fixedsystemonly)

B⁄B"-14x1"SelfDriller⁵⁄₁₆"HexHead,with⁵⁄₈"O.D.washer

B⁄B"-14xB⁄B"LongLifeLapTEK⁵⁄₁₆"HexHead,with1B⁄₈"O.D.washer

•Panelendlapsoversolidsubstrate

•18Gaugemaximum drilling thickness

¹⁄₄"-14x⁵⁄₈"LongLifeTypeBwithwasher

Fastener #12A •Rakeangletopurlin•Hipandvalleysupport plates to purlins•Valleyflashingtovalley

support plate

12x1"#2Phillips/SquareDrivePancakeHeadDriller

Deck Screw

Fastener#20914x2"Fastener#21014x3"Fastener#21114x4"Fastener#15D14x6"

Fastener #228 •DekstriptoExpansionRidge/ExpansionLap

10x¹⁄₂"AluminumGrommetWasher

Fastener #226 •DekstriptoExpansionRidge/ExpansionLap

³⁄₁₆"x⁹⁄₁₆"RivetCendalumClosedEndRivet

Fastener #18

14x1”TypeA⁵⁄₁₆"HexWasherHead,with⁵⁄₈"O.D.washer

q

q

q

q

q

q

q

q

q

q

qqqq

Page 23: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-21

BattenLok® HS

BLANK FEMALE

MALE

EAVE FEMALE

MALE DOWN SLOPE

MID FEMALE

MALE DOWN SLOPE

PEAK

THREE OR MORE PANELS FROM EAVE TO PEAK

ONE PANEL FROM EAVE TO PEAK

MORE THAN ONE PANEL FROM EAVE TO PEAKMORE THAN ONE PANEL FROM EAVE TO PEAK

FEMALE

MALE DOWN SLOPE

1¹⁄₂" 1¹⁄₂"4¹⁄₂" 4¹⁄₂"

SWA

GED

EN

D

SWA

GED

EN

D

INSTALLATION GUIDELINESI. JobsiteStorageandHandling A. Checktheshipmentagainsttheshippinglist. B. DamagedmaterialmustbenotedonBillofLading. C. Panelcratesshouldbehandledcarefully.Aspreaderbarofappropriatelengthisrecommendedfor

hoisting. D. Checktoseethatmoisturehasnotformedinsidethebundlesduringshipment.Ifmoistureis

present, panels should be uncrated and wiped dry, then restacked and loosely covered so that air can circulate between the panels.

II. ApplicationChecklist A. Checksubstructureforproperalignmentanduniformitytoavoidpaneldistortion. B. Periodiccheckofpanelalignmentiscrucialtoproperpanelalignment. C. Ifthereisaconflictbetweenthismanualandtheprojecterectiondrawings,theerectiondrawings

will take precedence.III. LTPWarning A. WARNING: Light transmitting panels are not designed or intended to bear the weight of any

person walking, stepping, standing or resting on them. THE MANUFACTURER DISCLAIMS ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, that any person can safely walk, step, stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation.

BattenLok® HSPanel Orientation

SHEETING DIRECTION FORROOFS WITH PANEL

ENDLAPS

RIGHT TO LEFT ONLY

SHEETING DIRECTION FORROOFS WITHOUT PANEL

ENDLAPS

LEFT TO RIGHT OR RIGHT TO LEFT

Page 24: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-22REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

PREPARATORY REqUIREMENTS

1. For the purpose of this manual, we have assumed that the BattenLok® HS roof will be installed over purlinsandaneavegutterwillbeinstalled.PleaserefertotheDesignSectionofthemanualsfordetailsof BattenLok® HS over other substrates.

2. Arakeangleoranalternatestructuralflatsurfacemustbeinstalledontopofthepurlinstoaccepttherake support.

3. All primary and secondary framing must be erected, plumbed and squared with bolts tightened accord-ing to accepted building practices.

4. Thesubstructure(eavetoridge)mustbeonplane(¹⁄₄”in20’or³⁄₈”in40’tolerance).5. It is critical that the purlins or bar joists at the ridge and endlaps be located exactly as detailed and that

they are straight from rafter to rafter. Any mislocation or bowing of these members can cause the fasten-ers at the ridge or endlaps to foul as the panels expand and contract.

6. Themanufacturerrecommendstheuseofascrewgunwithaspeedrangeof0-2000RPMtoproperlyinstallallfastenersreferencedinthismanual.Toolsratedto4000RPMshouldneverbeusedforselfdrilling fasteners typically supplied with metal roof and wall systems.

7. Fieldcuttingofthepanelsshouldbeavoidedwherepossible.Iffieldcuttingisrequired,thepanelsmustbecutwithnibblers,snips,orshearstopreventedgerusting.Donotcutthepanelswithsaws,abrasiveblades, grinders, or torches. All metal shavings must be removed from panel surfaces immediately.

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regu-lations. The manufacturer is not responsible for the performance of this roof system if it is not installed in accordance with the instructionsshowninthismanual.Deviationsfromtheseinstructionsanddetailsmustbeapprovedinwritingbythemanufacturer.

WARNING: Light transmitting panels are not designed or intended to bear the weight of any person walking, stepping, standing or resting on them. THE MANUFACTURER DISCLAIMS ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, that any person can safely walk, step, stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation.

CAUTIONDiaphragmcapabilitiesandpurlinstabilityarenotprovidedbytheBattenLok® HS roof system.

Therefore, other bracing may be required.

CAUTIONAvoid restricting the thermal expansion and cntraction of the BattenLok® HS panels.

(i.e.Donotattachpaneltothesubstructureatboththeeaveandridge.)

Page 25: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-23

BattenLok® HS

UNLOADING

Upon receiving material, check shipment against shipping list for shortages and dam-ages. The manufacturer will not be respon-sible for shortages or damages unless they are noted on the shipping list.

Eachbundleshouldbeliftedatitscenterofgravity.Wherepossible,bundlesshouldremainbrandeduntilfinalplacementonroof.If bundles must be opened, they should be retied before lifting.

Whenliftingbundleswithacrane,aspreaderbar and nylon straps should be used. NEvER USE WIRE ROPE SLINGS, THEY WILL DAMAGE THE PAELS.

Whenliftingbundleswithaforklift,forksmustbeaminimumoffivefeetapart.Donottrans-portopenbundles.Driveslowlywhencross-ing rough terrain to prevent panel buckling.

RIGHT WAY

5' Minimum

RIGHT WAY

WRONG WAY

WRONG WAY

CAUTIONImproper unloading and handling of bundles and crates may cause bodily injury or ma-terial damage. The manufacturer is not re-sponsible for bodily injuries or material dam-ages during unloading and storage.

Page 26: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-24REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

UNLOADING(Continued)

BLOCK AND BAND

This method of bundling is used for orders that are to be picked up by the customer or shipped bycommoncarrier. 2x4’sarestrappedun-der the bundles to allow access for straps or a forklift. Bundles less than25’ longmaybehandled by a forklift. The forklift should have atleast5’betweenforks.Bundleslongerthan25’shouldbeliftedutilizingaspreaderbarwithnylon straps.

FULL CRATE

This methond is used on all overseas ship-ments or by customer’s order. Handling re-quirements are the same as block and band.

Page 27: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-25

BattenLok® HS

HANDLING/PANELSTORAGE

Standing on one side of the panel, lift it by the seam. If thepanel isover10’ long, lift itwithtwo or more people on one side of the panel to prevent buckling.

Donotpickpanelsupbytheends.

Storebundledsheetsoffthegroundsufficientlyhigh to allow air circulation beneath bundle and to prevent rising water from entering bundle. Slightly elevate one end of bundle. Prevent rain from entering bundle by covering with tarpau-lin, making provision for air circulation between draped edges of tarpaulin and the ground. PROLONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED. If condi-tions do not permit immediate erection, extra care should be taken to protect sheets from white rust or water marks.

Checktoseethatmoisturehasnotformedin-side the bundles during shipment. If moisture is present, panels should be uncrated and wiped dry, then restacked and loosely covered so that air can circulate between the panels.

5'

10' to 12'

RIGHT WAY

WRONG WAY

10' to 12'

Page 28: BattenLok HS - Metl-Span

GENERAL INFORMATION

BHS-26REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

PROPER HANDLING, STORAGE AND MAINTENANCE OF PAINTED AND GALvALUME PLUS® PANELS

PANEL HANDLING

• All panel bundles must be inspected during unloading and carrier advised immediately if damage is noted.

• Neverunloadormovepanelbundlesthathavebeenopenedwithoutadequatelyclampingthem.Withoutthebanding to hold the bundle stable, panels may shift during unloading or movement, causing the bundle to fall.

• Never use wire slings to unload or move panel bundles.

• Whenunloadingormovingpanelbundlesover20’long,aspreaderbarmayberequired.Itistheerector’sresponsibility to determine the location and number of lift points required to safely unload or move panel bundles.

• Whenhandlingindividualpanels,alwayswearprotectivegloves.OSHAsafetyregulationsmustbefollowedatalltimes.

• Whencuttingpanels,alwayswearallrequiredsafetyequipmentsuchassafetyglassesandgloves.Cutpanelswithnibblers,shearsorsnips.DonotuseabrasivebladesawsasthesewillmelttheGalvalume® coating causing thepaneledgetorustwhichwillvoidtheGalvalume®andPaintwarranties.Drillingfastenersintopanelswillcreate metal filings that will rust and create an unsightly stain. Metal filings must be removed by sweeping or wiping down panels immediately after installation to avoid this occurrence.

PANEL STORAGE

• If water is permitted to enter panel bundles, it is necessary to open bundles, separate the panels and dry all surfaces.

• Store bundled panels off the ground sufficiently high to allow air circulation beneath bundle and to prevent rising water from entering bundle. Slightly elevate one end of bundle.

• Prevent rain from entering bundle by covering with tarpaulin, making provision for air circulation between draped edges of tarpalin and the ground.

• Prolonged storage of panels in a bundle is not recommended. If conditions do not permit immediate erection, extra care should be taken to protect panels from white rust or water marks. If panels have not been erected withinthreeweeksofreceipt,thepanelsshouldberemovedfromthebundleforinspection.Condensationmaycausedamagetopanels.Themanufacturer’spaintandGalvalume® warranties do not cover damage caused by improper panel storage.

PANEL MAINTENANCE

• NeverallowGalvalume® panels to come into contact with or water runoff from dissimilar materials such as copper, lead,orgraphite.ThesematerialswillcausegalvaniccorrosionofthepanelsandwillvoidtheGalvalume® warranty.ThisincludestreatedwoodandACcondensate,bothofwhichcontaincoppercompounds.Thisalsoapplies to painted panels.

• Always use long life fasteners in all exposed fastener applications. Non long life fasteners can rust through the panel at each exposed fastener location. Use of non long life fasteners in exposed applications will void the Galvalume® and Paint warranties.

• Panelsshouldbeprotectedagainstexposuretomasonryproducts,strongacidsorbasesandsolvents.ExposuretotheseagentsmayetchorstainGalvalumePlus® panels and cause painted panels to blister or peel.

Page 29: BattenLok HS - Metl-Span

GENERAL INFORMATION

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-27

BattenLok® HS

• Never allow anyone to apply any coating or patching material to the panel surface. These products may contain chemicals thatwilladverselyaffecttheGalvalumePlus® or paint coating. Also, water may become trapped between the coating material and the panel, causing premeture corrosiion.

If you have any question as to proper methods to use in the handling, storage or maintenance of these panels, call your nearest manufacturer representative.

NOTICEUniformvisualappearanceofGalvalumePlus®coatedpanelscannotbeguaranteed.TheGalvalumePlus® coating is subject to variances in spangle from coil to coil which may result in a noticeable shade variation in installed panels. The GalvalumePlus® coating is also subject to differential weathering after panel installation. Panels may appear to be different shades doe to this weathering characteristic. If uniform visual appearance is required, the manufacturer recommends that our prepainted Signature®200orSignature®300panelsbeusedinlieuofGalvalumePlus®. Shade variations in panels manufacturedfromGalvalumePlus® coated material do not diminish the structural integrity of the product. These shade variations should be anticipated and are not a cause for rejection.

Page 30: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-28REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

*Not by Manufacturer

RAKE ATTACHMENTAttach the rake angle to the purlin with the Fastener#12A.

Attach the rake support on top of the rake angle with the proper self-drilling fasteners (See“RakeSupportFastenerRequirements”Below)on2’-0”centerswithafastenerinthefirstandlastprepunchedslot.Theverticallegistobeinstalledflushwiththesteelline.

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SqUARE WITH THE EAvE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM.

Install6”longpiecesofdoublefacedtape(notbyManufacturer)on3’-0”centerstothetopofthe horizontal leg of the rake support. This will help hold the insulation in place at the rake.RAKE ANGLE ATTACHMENT

RAKE SUPPORT ATTACHMENT

STEEL LINE

FASTENER #12A

WALL PANEL

PURLIN

RAKE ANGLE

FLOATING SYSTEM

FIXED SYSTEM

FASTENER #5

*DOUBLE FACED TAPEFASTENER #1

RAKE SUPPORT

2³⁄₄"

STEP 1

RAKE SUPPORT FASTENER REqUIREMENTS

•Fixed System-Fastener#1•Floating System-Fastener#5

CAUTION(For Floating Systems Only)

It is important that shoulder fasteners are installedthroughtheCENTERoftheslottedholes of the rake support to allow for expan-sion and contraction.

IMPORTANT!ALL PRIMARY AND SECONDARY FRAM-ING MUST BE INSTALLED, PLUMBED, AND BOLTS TIGHTENED PRIOR TO SHEETING.

Page 31: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-29

BattenLok® HS

*Not by Manufacturer

LOW SYSTEM EAvEFor applications in which the wall panels have already been erected, install box panel cap trim or offset panel cap trim to the eave strut withFastener#14.Eave trimmustbepulledtight towallpanelswithFastener#14beforefastening to eave strut. For applications in which the wall panels have not been erect-ed, use offset panel cap trim. If using panel cap trim, it will space itself for the wall offset panels.UseFastener#14installedat36”O.C.

Install Tri-Bead tape sealer along top of thetrim.

For vinyl insulation, install double faced tape (notbyManufacturer)alongthelengthofthetoplegofthetrim.DoublefacedtapemustbeupslopefromTri-Beadtapesealer.

Laptrim2”.Applytwobeadsofurethaneseal-antbetweenthetrimpieces,approximately1”from the end of the bottom piece. Attach trim lapsinflateavetrimwithFastener#14.AttachtrimlapsonpanelcaptrimwithFastener#4.

WALL PANEL INSTALLED AFTER ROOF

WALL PANEL INSTALLED BEFORE ROOF

BOX PANEL CAP TRIMENDLAP DETAIL

OFFSET PANEL CAPTRIM ENDLAP DETAIL

FASTENER #14

URETHANESEALANT

2" LAP 1"

URETHANESEALANT

2" LAP

1"

OFFSETPANEL CAPTRIM

FASTENER #4

TRI-BEADTAPE SEALER

EAVE STRUT

BOX PANELCAP TRIM

FLAT EAVETRIM

WALL PANEL

*DOUBLE FACED TAPE

FASTENER #14@ 10'-0" O.C.

FASTENER #14@ 36" O.C.

2" MAX.

EAVE STRUT

OFFSET PANELCAP TRIM

*DOUBLE FACED TAPE

TRI-BEADTAPE SEALER

1¹⁄₄" MAX.

FASTENER #14@ 36" O.C.

FASTENER #14@ 10'-0" O.C.

STEP 2

Page 32: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-30REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

*Not by Manufacturer

HIGH SYSTEM EAvEWall Panels Installed Before Roof

Installhigheaveplatesflushwiththeoutsideface of the high crowns of the wall panels. Install Fastener #1 in prepunched slots (1’-0”oncenter)oftheeaveplate.Thefirsteaveplate will butt against the rake support. All of the eave plates may be installed at this time.

Be sure to butt each eave plate end to endwithout leaving a gap between the plates. Placean8”lengthofTripleBeadtapesealerat each butt joint.

Install box panel cap trim to the top of the eaveplates.Check tomake sure the trim isflatagainstthewall.AttachthetrimtotheeaveplateandthewallpanelwithaFastener#14at10’-0”centers.

LayTri-Beadtapesealeracrossthetopoftheeavetrim,flushwiththeoutsideedge.For vinyl back insulation, install double faced tape (not by Manufacturer) along the lengthofthebottomoftheeaveplate.DoublefacedtapemustbeupslopefromtheTri-Beadtapesealer.

Wall Panels Installed After Roof

Install offset panel cap trim to the eave strut and wall panel with Fastener #14 at 10’-0”centers. Use three fasteners per trim piece.

Installhigheaveplatesflushwiththeoutsideof the offset panel cap trim. Install Fastener #1ineachprepunchedslot(1’-0”oncenter)oftheeaveplate.Thefirsteaveplatewillbuttagainst the rake support. All of the eave plates may be installed at this time.

LayTri-Beadtapesealerundertheeaveplateon top of the offset panel cap trim.

Be sure to butt each eave plate end to endwithout leaving a gap between the plates. Placean8”lengthofTripleBeadtapesealerat each butt joint.

Lay Tri-Bead tape sealer across the top oftheeaveplates,flushwith theoutsideedge.For vinyl back insulation, install double faced tape(notbyBuildingManufacturer)alongthelength of the bottom leg of the eave plate.

Lap trim 2”. Apply two beads of urethanesealant between the trim pieces, approximately 1”fromtheendofthebottompiece.AttachtrimlapsinflateavetrimwithFastener#14.AttachtrimlapsonpanelcaptrimwithFastener#4.

RAKE SUPPORT

HIGH EAVE PLATE

FASTENER #1

EAVE STRUT

FACE OF WALL

EAVE STRUT

FASTENER #1

OFFSET PANELCAP TRIM

FASTENER #14@ 10'-0" O.C.

HIGH EAVE PLATE

TRI-BEADTAPE SEALER

TRI-BEADTAPE SEALER

1¹⁄₄" MAX.

*DOUBLE FACED TAPE

TRI-BEADTAPE SEALER

EAVE STRUT

FASTENER #1

*DOUBLE FACED TAPEBOX PANEL CAP

TRIM

HIGH EAVE PLATE

WALL PANEL

2" MAX.

FASTENER #14@ 36" O.C.

FASTENER #14@ 10'-0" O.C.

BOX PANEL CAP TRIMENDLAP DETAIL

OFFSET PANEL CAPTRIM ENDLAP DETAIL

FASTENER #14

URETHANESEALANT

2" LAP 1"2" LAP

1"

OFFSET PANELCAP TRIM

FASTENER #4

URETHANESEALANT

WALL PANEL INSTALLED AFTER ROOF

WALL PANEL INSTALLED BEFORE ROOF

FLAT EAVETRIM

STEP 2A

Page 33: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-31

BattenLok® HS

*Not by Manufacturer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)Position the thermal spacer on top of the in-sulation over each purlin and against the rake support prior to installing the roof panel.

Using spray adhesive, (not by Manufactur-er),adhere the thermal spacer to the insula-tion(FirstPanelRunOnly).Thethermalspac-er increases the insulation capacity along the purlins.

6" LONG PIECES @ 3'-0"

OFFSET PANEL CAP TRIM

THERMAL SPACER

*DOUBLE FACED TAPE

*DOUBLE FACED TAPE

INSULATION

THERMAL SPACER

THERMAL SPACER

*SPRAY ADHESIVE

RAKE SUPPORT

STEP 3

Page 34: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-32REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

*Not by Manufacturer

FIRST PANELPosition the panel so that it overhangs the eave strut by the dimension shown on the building drawings. The upper end of the panel mustextend7”beyondthewebof thepurlinif the panel covers eave to ridge. If more than one panel is required to cover eave to ridge, one or more endlaps will be required. The upperendofthepanelwillextend10”beyondthe web of the purlin at endlaps.

Laythefemalelegofthepanelovertherakesupport. To prevent wind damage, secure the female leg of the panel to the rake support with Vise Grip® Locking C-Clamps or temporaryfasteners. Fasteners must go through the rake support. The panel will not be fastened permanently to the rake support until the rake trim is installed.

Attach the panel to the eave strut or eave plate withFastener#1E.Fivefastenersarerequiredat this location.purlins.

BattenLok® HS PANEL

WALL PANEL

TRI-BEAD TAPE SEALER

FASTENER #1E

*DOUBLE FACED TAPE

INSULATION

WALL PANEL FASTENER

RAKE SUPPORT

FASTENER # 12A

FASTENER # 5 24" O.C.

WALL PANEL

RAKE ANGLE

EAVE STRUT

BattenLok® HS PANEL

Vise Grip® LOCKING

WALL PANEL FASTENER

EAVE STRUT

BattenLok® HS PANEL

WALL PANEL

WALL PANEL FASTENER

FASTENER # 12A

FASTENER # 5 24" O.C.

FASTENER # 1E

RAKE ANGLE

RAKE SUPPORT

FASTENER #14

SEE

DETAILS

FASTENING PATTERN AT EAVE

1" 1"3¹⁄₂" 3¹⁄₂" 3¹⁄₂" 3¹⁄₂"

2 3 4 5 1

BOX PANELCAP TRIM

C-CLAMP

1

STEP 4

NOTE:If an endlap is required then roof must be sheeted right to left as viewed from the eave looking toward the ridge.

Page 35: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-33

BattenLok® HS

CAUTIONThe panel clip has factory applied mas-tic in the upper lip. This mastic is com-pressed when the clip is rotated in place. If, for some reason, a clip must be re-moved, a new clip must be used.

CLIP INSTALLATIONHook the panel clip onto male leg of panel. Hold end of clip up to keep it engaged onto male leg and rotate the cip base down to completely engage clip onto male leg. Install panel clips at each purlin.

Beforefasteningcliptopurlins,checktoensurethat vertical leg of clip is tight to the vertical leg of the panel. Failure to keep this leg tight to the panel leg will affect panel module.

1

STEP 5

CLIP FASTENERREqUIREMENTS

Purlins-Fastener#1B-Upto4”InsulationFastener#142-Over4”InsulationBarJoists-Fastener#6A(Twofastenersperclip)

Page 36: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-34REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

NOTE:Ifyouareusing12”BattenLok® HS panels, they are not prepunched for endlaps. Use Triple Bead Tape Sealant at endlaps with12”widepanels.

ENDLAP-PANEL

Slide a prepunched back-up plate onto the upslope end of the bottom panel. Make sure the teeth on top of the back-up plate are on top of the panel. Visually check to ensure that the prepunched holes in the back-up plate are aligned with the prepunched holes in the panel. At upslope end of bottom panel, install Tri-Bead tape sealer across entire width ofpanel. Tape sealer must be centered over pre-punched holes in panel. Apply swaged endlap tape sealer to swaged vertical male leg of up-per panel. Pigtail portion of tape sealer must lap over vertical leg of panel.

Using an awl to align the prepunched holes, install upper panel by nesting it over the lower panelfor6”.Rotatethemalelegoftheupperpanel under the male leg of the bottom panel, then force the female leg of the upper panel down onto the female leg of the bottom panel. InstallFastener#1Eintheprepunchedholesin the proper sequence. Install clips as out-linedinStep5.

Repeat this endlap procedure as required until ridge is reached.

CROSS SECTION OF ENDLAP

1¹⁄₂"

UPPER SWAGEDBattenLok® HSPANEL FASTENER #1E

6"

TRI-BEAD TAPE SEALER

LOW CLIP

BACK-UP PLATE

4¹⁄₂"

10"

LOWERBattenLok® HSPANEL

FASTENER #1B

PANEL INSTALLATION SEQUENCE

TRI-BEAD TAPE SEALER

BACK-UP PLATE TEETH LOWER

BattenLok® HSPANEL

PREPUNCHED HOLES

SWAGED ENDLAP TAPE SEALER

UPPER SWAGEDBattenLok® HSPANEL

FASTENER SEQUENCE(With Striations)

FASTENER SEQUENCE(With Striations and Pencil Ribs)

2 3 4 5 1

FASTENER #1E

2 3 4 5 6 1

FASTENER #1E

12

STEP 6

NOTE:Step 6 applies only where more than onepanel is used in a single slope.

Page 37: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-35

BattenLok® HS

CAUTIONInstalling the tape sealer to the male leg at the ridge is important.Without it, watercould be driven behind the outside closure by a strong wind.

RIDGEAttheridge,thepanelshouldextend7”pastthe web of the peak purlin.

At the ridge install a back-up plate as outlined inStep6.

InstallclipsasoutlinedinStep5.

Install a 3” piece of Tri-Bead tape sealer atridgeconditionsor7”pieceofTri-Bead tapesealer at high eave conditions along the length of the male leg beginning at the upslope end of the panel and extending downslope. Install asecondpieceofTri-Beadtapesealeralongthe underside of the male leg beginning at the upslope end and extending downslope.

PANEL END SEALANT DETAIL AT RIDGE

7"

BACKUP PLATEBattenLok® HSPANEL

PEAKPURLIN

FASTENER #1B

BattenLok® HSLOW CLIP

3"

TRI-BEAD TAPE SEALER

7"

AT HIGH EAVE

AT RIDGE

BattenLok® HS PANEL

BACK-UP PLATE

RIDGE END OF PANEL

PEAK PURLIN

BattenLok® HS CLIP

3"

TRI-BEADTAPE SEALER

32

1

STEP 7

Page 38: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-36REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CAUTIONPanel must be crimped at all clip locations as they are installed to provide temporary wind resistance.

SUBSEqUENT RUNSEAvE

Apply urethane sealant to the male leg of thefirstpaneldirectlyovertheTri-Beadtapesealer at the eave. This will prevent water infiltrationthroughtheendofthepanelseam.

Position the next panel with the female leg over the male leg of the previous panel with panelendsflush.

Clampthepanelseamtogetheratbothends.Longpanelsmayrequireoneormoreclampsin the middle. This will help hold panel module.

InstallfastenersateaveasoutlinedinStep4.

InstallclipsasoutlinedinStep5.

Crimppanelseamatallcliplocationswithhandcrimping tool. Panels should be fully seamed with electric seamer as quickly as possible after a section of the roof is completed.

BattenLok® HSPANEL

EAVE STRUT

RAKE SUPPORT

RAKEANGLE

OFFSET PANELCAP TRIM

FASTENER #5

FASTENER #1E

FASTENER #12A

BattenLok® HSPANEL

URETHANESEALANT

TRI-BEADTAPE SEALER

BattenLok® HSPANEL

PANEL ENDSEALANT DETAIL

AT EAVE

Vise Grip®

LOCKINGC-CLAMP

FASTENER SEQUENCE

12 3 4 5

FASTENER #1E

4

32

1

STEP 8

Page 39: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-37

BattenLok® HS

SUBSEqUENT RUNSENDLAP

InstallendlappanelsasoutlinedinStep6.

InstallclipsasdescribedinStep5.

Repeat endlap procedures as required until ridge is reached.

UPPER SWAGEDBattenLok® HSPANEL

FASTENER #1E (5) PER PANEL

SWAGED ENDLAP TAPE SEALER

BACK-UP PLATE

TRI-BEAD TAPE SEALER

PURLIN

LOWERBattenLok® HSPANEL

FASTENER SEQUENCE

1 2 3 4 5

FASTENER #1E

4

31

25

STEP 9

Page 40: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-38REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

SUBSEqUENT RUNSENDLAP

Installback-upplateandTri-BeadtapesealerasoutlinedinStep6andStep7.

InstallclipsasdescribedinStep5.

3"

BattenLok® HSPANEL3" PIECE OF TRI-BEAD

TAPE SEALER ON TOP

TRI-BEAD TAPE SEALER

BattenLok® HSPANEL

BattenLok® HSPANEL

BACKUP PLATE

4

31

265

STEP 10

CAUTIONInstalling the tape sealer to the male leg at theridge is important. Without it,watercould be driven behind the outside closure by a strong wind.

Page 41: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-39

BattenLok® HS

LAST PANEL RUNInstallrakesupportatthefinishingendoftheroofasoutlinedinStep1.

FINISHING DIMENSION RUN OF 8” TO 14”

Fieldcutandbenda2”tallverticallegonthepanels in the last run of roof. The vertical leg must be tight to the rake support angle. Secure the vertical leg to the rake support angle with clamps or temporary fasteners. At the endlap and ridge, a partial back-up plate must be cut.

FINISHING DIMENSION RUN OF LESS THAN 8”

Ifthewidthofthelastpanelrunis8”orless,a second run of rake support angle must be installed for attachment of the vertical leg of the panel. A variable termination trim will be required to seal the gap between the vertical leg of the panel and the rake trim.

The male leg of the panel and the termination trimmustbefieldcuttofitthecondition.

PURLIN

RAKE ANGLE

PANEL FASTENER

WALL PANEL

BattenLok® HSFLOATING CLIP

FASTENER #12A

BattenLok® HSPANEL

FASTENER # 1B

FASTENER #5 24" O.C.

RAKE SUPPORT

RAKE SUPPORT RAKE SUPPORT

WALL PANEL

VARIABLE TERMINATION TRIM

TRI-BEAD TAPE SEALER

RAKE ANGLE

TRIM FASTENER

RAKE TRIM

PURLIN CLOSURE

BattenLok® HSPANEL

FASTENER # 12A

RAKE ANGLE

FASTENER #5 24" O.C.

FASTENER #5 24" O.C.

FASTENER #1E 24" O.C.

TRI-BEAD TAPE SEALER

FASTENER #4 6" O.C.

PANEL FASTENER

RAKE SLIDE

TRIM FASTENER

RAKE TRIM

CLOSURE

FASTENER #1E 24" O.C. TRI-BEAD

TAPE SEALER

RAKE SLIDE

8" TO 14"

8" MAX

4

31

265

6

STEP11

Page 42: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-40REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

SEAMING OPERATON

As panels are installed, hand seam at each clip with hand crimper. Panels should be completely seamed with electric seamer as soon as possible.

Push locking arm down to lock hand crimper ontoseam.Ifdifficultyisencountered,checkto make sure that hand crimper is properly aligned on seam. Do not force locking arm.

Push crimping arm down to crimp panel. Return both the crimping arm and locking arm to the up position and remove tool from seam.

STEP 1

CRIMPING ARM(UP POSITION)

LOCKING ARM(UP POSITION)

HAND CRIMPER POSITIONEDOVER SEAM

STEP 2HAND CRIMPER LOCKED

ON TO SEAM

CRIMPING ARM(UP POSITION)

LOCKING ARM(DOWN POSITION)

CRIMPING ARM (DOWN POSITION)

STEP 3HAND CRIMPER CRIMPS SEAM

LOCKING ARM (DOWN POSITION)

STEP 12

Page 43: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-41

BattenLok® HS

SEAMING OPERATON(Continued)

The electric seamer will run upslope and downslope and is controlled by a hand held forward and reverse remote switch. The seamer willformtheseamineitherdirection.Whenthepanels are installed from right to left forward is upslope and when the panels are installed left to right forward is downslope. An orientation plate on the seamer indicates forward and reverse. When the roof has endlaps, the panels will always be installed right to left.The remote switch is designed to stop the seamer when the button is released.On lower sloped roofs walking with the seamer is recommended.On steep sloped roofs (6:12 and greater) a12-gauge extension cord (not by BuildingManufacturer) may be installed between theremote switch and the seamer. Seaming can then be accomplished by starting the seamer attheeavefromasafetylift.Whenusingthismethod the seam will be formed upslope and then the seamer will be reversed down the seam to the eave, removed, and placed on the nextseam.Duringpanelinstallationhandcrimptheendofthepanels12”downslopefromtheridge or high side of the roof. Stop the seamer at this point to prevent the seamer from running intotheflashingorrunningofftheroof.Finishremainder of seam with the hand crimper.To begin seaming, set the seamer on the seam with the locking arm up and to the open side of the seam. The wheels should be even with the edge of the panel. Push the locking arm down to engage the tools and turn the seamer on.

12"

PANEL PROFILEBEFORE SEAMING

PANEL PROFILEAFTER SEAMING

STEP 12

CONT.

CAUTIONTheuseofanyfieldseamingmachineotherthanthatprovidedbythemanufac-turer may damage the panels, void all warranties and will void all engineering data.

CAUTION• Seamer operation should be closely supervised

at all times.• A safety line should be attached to the seamer.• Be aware of which direction the seamer will

move before engaging the switch.• Do not entangle the electrical cords in the

seamer tooling while it is in operation. This could cause serious injury or death to the operator and severely damage the seamer.

• Electricalcordsshouldbe10-gaugetoprovidepowertotheseamerandneverbeover200feetfrom the electrical source.

• Theseamerwillmoveapproximately6to8inch-es after the hand switch is released.

• Bringseamertoacompletestopbeforechang-ing direction.

Page 44: BattenLok HS - Metl-Span

INSTALLATION SEQUENCE

BHS-42REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OUTSIDE CLOSUREINSTALLATION

Panels must be hand folded flat (90°) for 3” with a hand tool to allow the outside closure to be installed.PlaceTri-Beadtapesealer across full width of panels, including under panel seams at ridge. Center of tapesealershouldbe1¹⁄₂”fromendofpanels.

Field cut the end of the outside closure that fitstotheopensideofthepanelseam.Notchand bend the vertical leg of the closure above the end tab back to the dimple formed into the closure.Itisimportantthattheclosuresfittightto the panel seams to prevent the need for excess urethane sealant at this location.

Install outside closures by rotating the end cut forthepanelseamintoplacefirst.Thenrotatethe other end of the outside closure into place. The vertical leg of the outside closure should be2”fromtheupslopeendofthepanel.Attachthe outside closure to the panel with Fastener #1Eateachprepunchedhole in theclosure.Before installing the next outside closure,installapieceofTri-Beadtapesealerontothetop flange of the outside closure previouslyinstalled. This is to prevent water being blown between the outside closures where the top flangesoverlap.Afterallclosuresareinplace,install Tri-Bead tape sealer across the topflange.

Useurethanesealanttofillanyvoidsaroundthe panel seams on the upslope side of the outside closures.

FASTENER #17

SUBSEQUENTOUTSIDE CLOSURE

FIRST OUTSIDECLOSURE

FASTENER #17

TRI-BEADTAPE SEALER

BACK-UP PLATE

DOWN

SLOPE

1 ¹⁄₂"

DOWN SLOPE

3"

DOWN

SLOPE

1 ¹⁄₂"

STEP 13

Page 45: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-43

BattenLok® HS

1. BattenLok® HS PANEL2. BattenLok® HS LIGHT TRANSMITTING PANEL3. LIGHT TRANSMITTING PANEL STIFFENER PLATE4. BACK-UP PLATE5. PURLIN

FIELD NOTCH PANEL FOR ENDLAP

4

2

3 5

4

1

SEALANT (Factory Applied)

BattenLok® HSLIGHT TRANSMITTINGPANEL

FASTENER #1E(TWO EACH SIDE)

STIFFENER PLATE[HW-7747]

6”

FIELD NOTCHREQUIRED

(Panels at this side oflight transmitting panelremoved for clarity)

BattenLok® HSLIGHT TRANSMITTINGPANEL

BattenLok® HSLIGHT TRANSMITTINGPANEL

NOTES:1. Maximumwidthofpurlinflangetobe3¹⁄₂”.2. Stiffenerplateistobefieldinstalledonbottomsideoflighttransmittingpanelovermid-purlin.3. LighttransmittingpanelrivetsthatobstructstiffenerplatemustbedrilledoutandreplacedwithFastener#1E.Minimumtwo

fasteners per side.4. Stiffener plate must be centered exactly over mid-purlin so that thermal movement of the system is not restrained by the

purlin.5. Endlapscreatedbytheuseoflighttransmittingpanelsrequirerooferectiontoproceedfromrighttoleftasviewedfromthe

eave looking toward the ridge.

WARNINGIt is the user’s responsibility to ensure that the installation and use of all light transmitting panels comply with State, Federal and OSHA regulations and laws, in-cluding,butnotlimitedto,guardingalllighttransmittingpanelswithscreens,fixedstandardrailings,orotheracceptablesafetycontrolsthatpreventfall-through.

Page 46: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-44REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

6"

BUTYL TUBE SEALANT

TRIPLE BEADTAPE SEAL

BACK-UP PLATE

TO BOTTOM OF

TAPE SEALANTLOWER BattenLok® HS PANEL

NOTCH FEMALE LEG 6"ON BOTTOM RETURN

NOTCH

MALE LEG

FEMALE LEG

BattenLok® HS LTP

DOWN SLOPEEND OF LTP

¹⁄₄"

FIELD CUT

6"

FIELD OPEN

6"

RIvETED RAIL LTP INSTALLATION

LOWER BATTENLOK HS PANEL1. InstallBack-upplateonlowerpanel.2. InstallTripleBeadTapeasshownonlowerpanel.3. InstallButylSealantasshownuptheverticallegsandoverthemaleandfemaleseam.

STEP 2

STEP 1

DOWN SLOPE END OF LTP1. Fieldcutmaleleg6”asshown.2. Fieldopenfemaleleg6”toallowpanellaptoengage.

Page 47: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-45

BattenLok® HS

LOWER BattenLok® HS PANEL

UPPERBattenLok® HS LTPUPPER

BattenLok® HS LTP

LOWER BattenLok® HS PANEL

FASTENER LOCATION1¹⁄₂" FROM END OF PANEL

¹⁄₄-14 X 1¹⁄₄" LONG-LIFES.D. W/OVERSIZED BONDEDWASHER (FASTENER #43L)

UPPERBattenLok® HS LTP

1" 1"3" 4" 4" 3"

5 3 1 2 4

STEP 3

UPPER AND LOWER PANELS1. C-clampbothverticalmalelegstogetherpriortorotatingupperpanelintoplace.2. LiftLTPupslightlyincenterofpaneltohelpgetmaleandfemalelegstonestproperly.

STEP 4

UPPER AND LOWER PANELS1. C-clampbothfemaleverticallegstogether.2. Install1/4-14x11/4”longlifefasteners(43L)inthesequenceshown.

RIvETED RAIL LTP INSTALLATION (cont’d.)

Page 48: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-46REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

BACK-UP PLATE

BUTYL TUBE SEALANTBUTYL TUBE SEALANT ON TOP OF TRIPLE BEAD TAPE SEAL

BattenLok® HS LTP 6"

TO BOTTOM OF

TAPE SEALANT

NOTCH FEMALE LEG 6"ON BOTTOM RETURN

NOTCH

¹⁄₄"

UPPERBattenLok® HS PANEL

FIELD OPEN

6"

FIELD CUT

6"

RIvETED RAIL LTP INSTALLATION (cont’d.)

UPSLOPE END OF LTP1. InstallBack-upplateonLTPpanel.2. InstallTripleBeadTapeasshownonLTPPanel.3. InstallButylSealantasshownuptheverticallegsandoverthemaleandfemaleseam.4. Apply generous bead of butyl sealant on top of triple bead tape sealer.

STEP 6

STEP 5

UPPER BATTENLOK HS PANEL DOWN SLOPE END1. Fieldcutmaleleg6”asshown.2. Fieldopenfemaleleg6”toallowpanellaptoengage.

Page 49: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-47

BattenLok® HS

STEP 7

LOWER BattenLok® HS LTP

UPPERBattenLok® HS PANEL

LOWERBattenLok® HS LTP

LOWER BattenLok® HS PANEL

¹⁄₄-14 X 1¹⁄₄" LONG-LIFES.D. W/WASHER (FASTENER #1E)

UPPERBattenLok® HS PANEL

1" 1"3" 4" 4" 3"

LOWERBattenLok® HS LTP

FASTENER LOCATION1¹⁄₂" FROM END OF PANEL

5 3 1 2 4

RIvETED RAIL LTP INSTALLATION (cont’d.)

UPPER AND LOWER PANELS1. C-clampbothverticalmalelegstogetherpriortorotatingupperpanelintoplace.2. Liftpanelupslightlyincenterofpaneltohelpgetmaleandfemalelegstonestproperly.

STEP 8

UPPER AND LOWER PANELS1. C-clampbothfemaleverticallegstogether.2. Install1/4-14x11/4”longlifefasteners(#1E)inthesequenceshown.

Page 50: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-48REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CURB INSTALLATIONFLOATING ROOF CURB SUPPORT GUIDE

INDICATES ROOF PANEL SUPPORTS INDICATES CURB BASE SUPPORTS

* ADDITIONAL UPLIFT SUPPORTS ARE REQUIRED FOR THE ATTACHMENT OF THE CURB UP LIFT PLATES ONLY.

BattenLok® HSROOF PANEL

CURB

* *

EQUAL EQUAL

CURB BASE WIDTH

OPENING + 3"

3" 3"

BattenLok® HSROOF PANEL

PANEL MOVEMENT± 1 ¹⁄₄"

10"

CURB

FLOATING EAVE PLATE PURLIN LINE

³⁄₈"

LOW

CLI

PS

1" H

IGH

CLI

PS

CURB BASE LENGTH

10" CLEAR OPENING + 3"

28"

4"

6" 6"

1'-2"

10"

BattenLok® HSROOF PANEL

BattenLok® HSROOF PANEL

DOWN SLOPE

UP SLOPE

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

Page 51: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-49

BattenLok® HS

CURB INSTALLATIONCURB BASE INSTALLATION #1

BACK UP PLATE(HW-7766)

UP LIFT SUPPORT

(PANEL RIB TO PANEL RIB)

DOW

N SL

OPE

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2

SHEETING DIRECTION

ROOF PANEL #1

UPLIFTSUPPORT

PANEL CLIP(TYPICAL)

PANELSUPPORT

PANELSUPPORT

PLUS 3"CURB CLEAR OPENING

10"

4'-0"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

NOTES:1. Install all lower roof panels to support the curb base.2. Install back up plates.

Page 52: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-50REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CURB INSTALLATIONCURB BASE INSTALLATION #2

BACK UP PLATE(HW-7766)

UP LIFT SUPPORT

DOW

N SL

OPE

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2

SHEETING DIRECTION

ROOF PANEL #1

UPLIFTSUPPORT

PANEL CLIP(TYPICAL)

PANELSUPPORT

PANELSUPPORT

PLUS 3"CURB CLEAR OPENING

10"

TRIPLE BEADTAPE SEALER

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

NOTES:1. ApplyTripleBeadtapesealer(HW-502)onroofpanelsasshown.

Page 53: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-51

BattenLok® HS

CURB INSTALLATIONCURB BASE INSTALLATION #3

PANELSUPPORT

CURB BASE

NOTCH CURBBASE

OPENING

10"

10"

¹⁄₂"

6"

PANELSUPPORT

DOW

N SL

OPE

SHEETING DIRECTION

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1PANEL CLIP(TYPICAL)

¹⁄₂"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

NOTES:1. ForfieldlocatedPanelFinCaps,notchCurbBaseatallPanelFins.2. InstallCurbBaseonlowerroofpanelswitha6”EndLap.

Page 54: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-52REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

PANEL SUPPORT

CURB BASE

FASTENER #1E¹⁄₄" - 14 X 1 ¹⁄₄"(4 FOR PANEL #2 & #4, 3 FOR PANEL #3)

OPENING

4"

PANEL SUPPORT

DOW

N SL

OPE

SHEETING DIRECTION

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1 PANEL CLIP (TYPICAL)

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

NOTES:1. AttachtheCurbBasetotheroofpanels.

CURB INSTALLATIONCURB BASE INSTALLATION #4

Page 55: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-53

BattenLok® HS

TRIPLE BEAD TAPE SEALER (HW-502)

LOOSE CAP CELL (SUPPLIED BY CURB MFG.)

FASTENER #1E¹⁄₄ - 14 X 1 ¹⁄₄"AT 1" O.C.

CURB BASE

PANEL RIB

STEP 2 STEP 1

FILL THE END OF THE CAP CELL WITH URETHANE TUBE SEALANT

1"

6"

SHEETING DIRECTION

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

NOTES:FillFincavityofCapCellwithUrethaneTubeSealant.ApplyTripleBeadtapesealer(HW-502)onthebottomof(2)loosetheCapCell,installoverthePanelFinsandattachwithFastener#1Eat1”O.C.

CURB INSTALLATIONCAP CELL INSTALLATION

Page 56: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-54REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

FIELD CUT

WASTE MATERIAL

WASTE MATERIAL

MAL

E PA

NEL

FIN

FEM

ALE

PAN

EL F

IN

PAN

EL L

ENG

TH =

CU

RB

BASE

LEN

GTH

CUT LINE

2" 1'-0" 2"

1'-4"

2" 2"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONCURB PANEL FIN PREPARATION

NOTES:Field cut male and female panel ribs from an extra roof panel supplied by the manufacturer.

Page 57: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-55

BattenLok® HS

PANEL #2

TRIPLE BEAD TAPE SEALER (HW-502) (FULL LENGTH ON CURB BASE)

PANEL #1

6"

FEMALE PANEL FIN (FIELD CUT FROM EXTRA PANEL)

PANEL #2 MALE RIB

FASTENER # 1E¹⁄₄-14 X 1 ¹⁄₄"

CURB BASE

BACK UP PLATE

PANEL #1 MALE RIB

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONFEMALE PANEL FIN INSTALLATION

NOTES:1. InstallTripleBeadtapesealer(HW-502)topanel#2MaleFin,andalongtheedgeoftheCurbBase.2. InstalltheFemalePanelRiboverthetapesealerandattachwithFastener#1Eat12”O.C.

Page 58: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-56REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

TRIPLE BEADTAPE SEALER(HW-502)

(FIELD NOTCH PANEL)

PANEL #4

¹⁄₄"

3"

3"

MALE PANEL FIN (FIELDCUT FROM EXTRA PANEL)

TRIPLE BEAD TAPE SEALER (HW-502)(FULL LENGTH ON CURB BASE)

BACK UP PLATE

CURB BASE

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONMALE PANEL FIN INSTALLATION

NOTES:1. NotchtheMalePanelFin.ApplyTripleBeadtapesealer(HW-502)tothetopandsideoftheMalePanelFin.2. ApplyTripleBeadtapesealerontheCurbBaseundertheMalePanelFin.3. InsertthefieldcutMalePanelFinontopoftheTripleBeadtapesealer.

Page 59: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-57

BattenLok® HS

CURB BASE

FEMALE PANEL FIN(FIELD CUT)

OPENING

MALE PANEL FIN(FIELD CUT)

TYP.

MAX

.1'

-0"

SHEETING DIRECTION

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1

PANELSUPPORT

PANELSUPPORT

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONCURB BASE INSTALLATION #5

Page 60: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-58REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CURB BASE

FEMALE PANEL FIN

OPENING

MALE PANEL FIN

SHEETING DIRECTION

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1

PANELSUPPORT

PANELSUPPORT

DO

WN

SLO

PE

TRIPLE BEADTAPE SEALER(HW-502)

10"

4"6"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONCURB BASE INSTALLATION #6

NOTES:1. ApplyTripleBeadtapesealer(HW-502)onCurbBaseattheuphillend.

Page 61: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-59

BattenLok® HS

TRIPLE BEADTAPE SEALER(HW-502)

MALE RIB

ROOF PANEL #6

FEMALE RIB

ROOF PANEL #5

CURB BASE

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONCURB BASE INSTALLATION #7

NOTES:1. ApplyTripleBeadtapesealer(HW-502)betweenthePanelRibsonPanels#5and#6forwaterseal.

Page 62: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-60REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CURB BASE

OPENING

ROOF PANEL #4 ROOF PANEL #3 ROOF PANEL #2 ROOF PANEL #1

PANEL SUPPORT

PANEL SUPPORT

DO

WN

SLO

PE

10"

4"

6"

SEE CURB BASE INSTALLATION #7

ROOF PANEL # 8

ROOF PANEL #7 ROOF PANEL #5 ROOF PANEL #6 FASTENER #1E¹⁄₄"-14 X 1 ¹⁄₄"(5 FOR EACHPANEL)

12" M

AX.

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONCURB BASE INSTALLATION #8

NOTES:1. InstallRoofPanels#5,#6&#7totheCurbBaseonTopofthetapesealerwithFastener#1E(5perpanel).2. InstallRoofPanel#8.

Page 63: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-61

BattenLok® HS

NOTE: SLOT LOCATION IS DETERMINED BY THE CURB LENGTH, MAXIMUM SPACING IS 12" O.C.

UP LIFT SUPPORT

CURB BASE

UPLIFT PLATE

⁵⁄₁₆" X 3" SLOTS

FACTORY WELDED

CLEAR OPENING

CURB BASE

2"

3" 3" NOTE NOTE 3" 3"

MOVEMENT

± 1 ¹⁄₄"

BLANKET INSULATION

CURB BASE

BOTTOM OFBattenLok® HSPANEL

FASTENER #5¹⁄₄"-14 X 1 ¹⁄₄"SHOULDER TEK® 2

UPLIFT SUPPORT

FIELD CUT AROUND INTERIOR PURLIN

UPLIFT PLATE (FACTORY INSTALLED)

CURB CLEAR OPENING

2"

1 ¹⁄₂"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONUPLIFT PLATE DETAIL

Page 64: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-62REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

UPLIFT PLATE MUST BE FIELD NOTCHED AROUND THE BUILDING PURLIN TO ALLOW FOR PANEL MOVEMENT.

CURB UPLIFT PLATE (BY CURB MFG.)

PURLIN

BOTTOM OF CURB BASE

HIG

H

CLI

PS

1"

LOW

C

LIPS

1 ¹⁄₂" 4 ¹⁄₂"

6"

³⁄₈"

MOVEMENT

± 1 ¹⁄₄"

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONUPLIFT PLATE FIELD NOTCH

Page 65: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-63

BattenLok® HS

BACK UP PLATE (HW-7766)

TRIPLE-BEAD TAPE SEALER (HW-502)

CLIP SCREWS(2) FASTENER #1B12-14 X 1"

BLANKET INSULATION

DOWN HILLPANEL SUPPORT(8C 3¹⁄₂" X 14 GA)

FASTENER #1E¹⁄₄"-14 X 1¹⁄₄" (5 PER PANEL)

³⁄₈" LO

W

1" H

IGH

4"

10"

6"

1¹⁄₂"

MOVEMENT

± 1"

BattenLok® HSPANEL

CURB BASE

PANEL CLIP

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONDOWN SLOPE CURB BASE END LAP

Page 66: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-64REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

CAUTIONIt is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHAregulationsandlaws,including,butnotlimitedto,guardingroofopeningswithplywood,fixedstandardrailingsorotheraccetable safety controls that prevent fall-through.

CURB INSTALLATIONUP SLOPE CURB BASE END LAP

FLOATINGEAVEPLATE

HW-7611HW-7601 LOW HIGH

1 ¹⁄₂"

CURBBASE

TRIPLE-BEAD TAPESEALER (HW-502)

FASTENER#5¹⁄₄"-14X1 ¹⁄₄"SHOULDERTEK®2@12"O.C.

BLANKET INSULATION

UPSLOPEPANELSUPPORT(8C3¹⁄₂"X14GA)

FASTENER#1E¹⁄₄"-14X1 ¹⁄₄"(5PERPANEL)

³⁄₈" LO

W

1" H

IGH

4"

10"

6"

1 ¹⁄₂"

MOVEMENT

± 1 ¹⁄₄"

BattenLok® HSPANEL

Page 67: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspan.comFORCURRENTINFORMATIONREV01.01BHS-65

BattenLok® HS

PIPE PENETRATION INSTALLATIONRECOMMENDED SMALL AND LARGE PIPE PENETRATION INSTALLATION

RIGHT WAY

RECOMMENDED SMALL PIPE PENETRATION INSTALLATION INSTALLPIPEINCENTEROFPANEL TO ALLOWBASEOFRUBBERROOFJACKTOLAYFLAT ON PANEL.

WRONG WAY

RECOMMENDED LARGE PIPE PENETRATION INSTALLATION THISMETHODTOBEUSEDIN ALLCASESWHERE APIPEPENETRATIONINTERSECTSA PANELRIBORWHEN THEPIPEIS TOOLARGEANDWILL NOT ALLOWADEQUATEWATER FLOWDOWNTHEPANEL.

PIPECURB

PURLIN

BattenLok® HSPanel

STAINLESSSTEELCLAMP (NOTBY BUILDINGMANUFACTURER)

1'-0" (MIN) (TYP)

ROOF SLOPE

BattenLok® HSPANEL

Page 68: BattenLok HS - Metl-Span

SPECIAL ERECTION TECHNIQUES

BHS-66REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

PIPE PENETRATION INSTALLATIONDECK-TIGHT INSTALLATION

STAINLESSSTEELCLAMP (NOTBY BUILDINGMANUFACTURER)

TRI-BEADTAPESEALER (HW-504)

DECK-TIGHT(NOTBY BUILDINGMANUFACTURER)ROLL TOP OFDECK-TIGHTDOWN

¹⁄₄"-14x⁷⁄₈"LONGLIFELAP TEK®

S.D.W/WASHER(FASTENER#4)@1"O.C.

STEP 1

STAINLESSSTEELCLAMP (NOTBY BUILDINGMANUFACTURER)

TRI-BEADTAPESEALER (HW-504)

APPLY TRI-BEADTAPESEALER CONTINUOUSLY AROUNDPIPE(HW-504)

DECK-TIGHT (NOTBY BUILDINGMANUFACTURER) ¹⁄₄"-14x⁷⁄₈"LONGLIFELAP TEK®

S.D.W/WASHER(FASTENER#4)@1"O.C.

STEP 2

NOTE:ROLLDECK-TIGHT UP OVERTRI-BEADTAPESEALER ANDSECURECLAMP AROUNDTOP OFDECK-TIGHT

TRI-BEADTAPESEALER (HW-504)

STAINLESSSTEELCLAMP (NOTBY BUILDINGMANUFACTURER)

TRI-BEADTAPESEALER (HW-504)

DECK-TIGHT (NOTBY BUILDINGMANUFACTURER)

¹⁄₄"-14x⁷⁄₈"LONGLIFELAP TEK®

S.D.W/WASHER(FASTENER#4)@1"O.C.STEP 3

Page 69: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-67

BattenLok® HS

OPEN FRAMINGFIXED EAvE WITH HANG ON GUTTER

2³⁄₄"

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)(2PERSTRAP)

¹⁄₄"-14x⁷⁄₈"LONGLIFELAPTEKW/WASHER[FASTENER#4]@12"O.C.

WALL PANEL

THICKNESS

BOXPANELCAP TRIM(FL-272)

GUTTERSTRAP(FL-246)@EVERY OTHERRIB

BUILDINGDIM.

URETHANETUBESEALANTBETWEENPANELRIBS

TRI-BEADTAPESEALER(HW-504)

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(5)PER16"PANEL(4)PER12"PANEL

¹⁄₈"x³⁄₁₆"POP RIVET(FASTENER#14)@10'-0"O.C.

SCULPTUREDGUTTER(FL-248A)

EAVESTRUT

WALL PANEL

BattenLok® HSPANEL

URETHANESEALANTMUSTCOMEINCONTACTWITHTAPESEALERTO FORM A WEATHERTIGHT SEAL

EAVEENDOF PANEL

URETHANETUBESEALANTBETWEENPANELRIBS FASTENER SPACING @ EAvE

VARIES

BattenLok® HSPANEL

1" 1"3¹⁄₂" 3¹⁄₂" 3¹⁄₂" 3¹⁄₂"

2"

1"12"

1"3⁵⁄₁₆" 3⁵⁄₁₆" 3⁵⁄₁₆"

2"

12-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#3)

¹⁄₈"x³⁄₁₆"POP RIVET(FASTENER#14)@3'-0"O.C.

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)

BattenLok® HS PANEL

GUTTERSTRAP(FL-246)@EVERY OTHERRIB

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)(2)PERSTRAP

GUTTER STRAP ATTACHMENT

16"

EAvE SEALANT DETAIL

Page 70: BattenLok HS - Metl-Span

DETAILS

BHS-68REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OPEN FRAMINGFIXED EAvE WITH EAvE TRIM

TRI-BEADTAPESEALER(HW-504)

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(5)PER16"PANEL(4)PER12"PANEL

¹⁄₈"x³⁄₁₆"POP RIVET(FASTENER#14)@12"O.C.

¹⁄₈"x³⁄₁₆"POP RIVET(FASTENER#14)@10'-0"O.C.

WALL PANEL

THICKNESS VARIES W/

ROOF SLOPE

BOXPANELCAP TRIM(FL-272)

EAVESTRUT

BUILDINGDIM.

WALL PANEL

SCULPTUREDEAVETRIM(FL-253)

BattenLok® HSPANELURETHANESEALANTMUSTCOME

INCONTACTWITHTAPESEALERTO FORM A WEATHERTIGHT SEAL

EAVEENDOF PANEL

VARIES

BattenLok® HSPANEL

FASTENER SPACING @ EAvE

EAvE SEALANT DETAIL

1" 1"3¹⁄₂"3 ¹⁄₂"3 ¹⁄₂"3 ¹⁄₂"

2"

1"12"

1"3⁵⁄₁₆"3 ⁵⁄₁₆"3 ⁵⁄₁₆"3 ⁵⁄₁₆"

2"

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)

16"

URETHANETUBESEALANTBETWEENPANELRIBS

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)(2PERSTRAP)

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER[FASTENER#4](2PERSTRAP)

12-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER[FASTENER#3]

URETHANETUBESEALANTBETWEENPANELRIBS

³⁄₄"

Page 71: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-69

BattenLok® HS

OPEN FRAMINGFLOATING RIDGE

TRI-BEADTAPE SEALER(HW-504)

TRI-BEAD TAPE SEALER(HW-504) CONTINUE ACCROSS PANEL

12"

2"5"

RIDGE TRIM(FL-213)

ZEE PURLIN

³⁄₈"

LOW FLOATINGCLIP (HW-220) OUTSIDE CLOSURE

(HW-440) @ 16" PANEL(HW-446) @ 12" PANEL

BACK-UP PLATE(HW-7766) @ 16" PANEL(HW-7764) @ 12" PANEL

TRI-BEAD TAPE SEALER(HW-504)

RIDGE ENDOF PANEL

3"

BattenLok® HSPANEL

¹⁄₄"-14 x 1¹⁄₄" SELF DRILLERW/O WASHER (FASTENER #1B)(2) PER CLIP ¹⁄₄"-14 x 1¹⁄₄" LONG-LIFE

SELF-DRILLER W/WASHER(FASTENER #1E)(4) PER 16" PANEL(3) PER 12" PANEL

¹⁄₄"-14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E) (1) PER RIB

¹⁄₄"-14 x ⁷⁄₈" LONG LIFE LAPTEKW/WASHER (FASTENER #4)@ 6" O.C. (DO NOT INSTALLTHRU PANEL RIB)

URETHANE TUBE SEALANT@ CLOSURE ENDS/PANEL RIB& LAPPING CLOSURE TABS TOSEAL ALL VOIDS

Page 72: BattenLok HS - Metl-Span

DETAILS

BHS-70REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OPEN FRAMINGFLOATING vENTED RIDGE

TRI-BEAD TAPESEALER (HW-504)

TRI-BEAD TAPE SEALER(HW-504) CONTINUEDACCROSS PANEL

12"

2" 5"

RIDGE TRIM(FL-303)

PERFORATEDVENT DRIP(FL-254)

ZEE PURLIN

³⁄₈" LOW FLOATINGCLIP (HW-220)

OUTSIDE CLOSURE(HW-440) @ 16" PANEL(HW-446) @ 12" PANEL

BACK-UP PLATE(HW-7766) @ 16" PANEL(HW-7764) @ 12" PANEL

¹⁄₄"-14 x ⁷⁄₈" LONG-LIFE LAP TEKW/WASHER (FASTENER #4) @ 6" O.C.(DO NOT INSTALL THRU PANEL RIB)

TRI-BEAD TAPE SEALER (HW-504)

RIDGE END OF PANEL

3"

BattenLok® HSPANEL

URETHANE SEALANT [HW-504]

PERFORATEDVENT DRIP(FL-254)

1"LAP (MIN.)

¹⁄₄"-14 x 1¹⁄₄" SELF-DRILLER W/O WASHER (FASTENER #1B)(2) PER CLIP

¹⁄₄"-14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E)(4) PER 16" PANEL(3) PER 12" PANEL

¹⁄₄"-14 x ⁷⁄₈" LONG-LIFE LAPTEKW/WASHER (FASTENER #4) @ 6" O.C.

URETHANE TUBE SEALANT@ CLOSURE ENDS/PANEL RIB� LAPPING CLOSURE TABS TOSEAL ALL VOIDS

¹⁄₄"-14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E) (1) PER RIB

Page 73: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-71

BattenLok® HS

OPEN FRAMINGRAKE

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)

@12"O.C.

12-14 X 1¹⁄₄"LONG-LIFESELFDRILLERW/WASHER

(FASTENER#3)

HIGHWINDRAKESLIDE(F-215)

SCULPTUREDRAKETRIM (FL-111)

2"X4"X16GA.RAKEANGLE

ZEEPURLIN

12-14X1"PANCAKEHEADSELFDRILLER(FASTENER#12A)(1)PERCONN.@EACHPURLIN

¹⁄₄"-14x1¹⁄₄"SHOULDERTEK® 2SELFDRILLER(FASTENER#5)@24"O.C.(CENTERINSLOT)

¹⁄₄"-14x1¹⁄₄"SELFDRILLERW/OWASHER(FASTENER#1B)(2)PERCLIP

BattenLok® HS PANEL

LOWFLOATINGCLIP(HW-220)

LOWRAKESUPPORTANGLE(HW-7712)

FIELDCUT&BENDUP2"PANELLEGASREQ’DWHENENDINGOFFMODULE

¹⁄₄"-14x1¹⁄₄"LONGLIFESELFDRILLERW/WASHER(FASTENER#1E)@24"O.C.TRI-BEADTAPESEALER

(HW-504)

OUTSIDECLOSURE

WALL PANEL

Page 74: BattenLok HS - Metl-Span

DETAILS

BHS-72REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OPEN FRAMINGRAKE WITH CLEAT

WALL PANEL

OUTSIDECLOSURE

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)

@12"O.C.

12-14 x 1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#3)

HIGHWINDRAKESLIDE(F-215)

SCULPTUREDRAKETRIM (FL-111)

2X4X16GA.ANGLE

ZEEPURLIN

12-14X1"PANCAKEHEADSELF-DRILLER(FASTENER#12A)(1)PERCONN.@EACHPURLIN

¹⁄₄"-14x1¹⁄₄"SHOULDERTEK® 2SELFDRILLER(FASTENER#5)@24"O.C.(CENTERINSLOT) ¹⁄₄"-14x1¹⁄₄"SELFDRILLER

W/OWASHER(FASTENER#1B)(2)PERCLIP

¹⁄₄"-14x1¹⁄₄"LONGLIFES.D.W/WASHER(FASTENER#1E)

@24"O.C.

¹⁄₄"-14x⁷⁄₈"LONGLIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.

SuperLok® PANEL

LOWFLOATINGCLIP(HW-220)

HIGHWINDPARAPETRAKECLEAT (F-292)

LOWRAKESUPPORTANGLE(HW-7712)

FIELDCUT&BENDUP2"PANELLEGASREQ’DWHENENDINGOFFMODULE

TRI-BEADTAPESEALER(HW-504)

Page 75: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-73

BattenLok® HS

OPEN FRAMINGPARAPET RAKE

1¹⁄₂"

BUILDINGDIM.

FEILDSAWCUT

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

MASONRY WALL(NOTBY METL-SPAN)

LOWRAKESUPPORT ANGLE(HW-7712)

FIELDCUT&BENDUP2"PANELLEGASREQ’DWHEN

ENDINGOFFMODULE

(MIN.)

14-10x2"DECKSCREW(FASTENER#209)@24"O.C.

(PRE-DRILLHOLE)

¹⁄₄"-14x1¹⁄₄"SHOULDERTEK® 2SELFDRILLER(FASTENER#5)@24"O.C.(CENTERINSLOT) ¹⁄₄"-14x1¹⁄₄"SELFDRILLER

W/OWASHER(FASTENER#1B)(2)PERCLIP

2X4X16GA.RAKEANGLE

12-14X1"PANCAKEHEADSELFDRILLER(FASTENER#12A)(1)PERCONN.@EACHPURLIN

ZEEPURLIN

BattenLok® HS PANEL

LOWFLOATINGCLIP(HW-220)

¹⁄₄"-14x1¹⁄₄"LONG-LIFES.D.W/WASHER(FASTENER#1E)@24"O.C.

HIGHWINDPARAPETRAKECLEAT(HW-292)

PARAPETRAKETRIM(FL-285)

COUNTERFLASH(FL-341)

URETHANETUBESEALANTCONTINUOUS

FLEXIBLEMEMBRANE

Page 76: BattenLok HS - Metl-Span

DETAILS

BHS-74REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OPEN FRAMINGFLOATING HIGH SIDE EAvE

BattenLok® HSPANEL

LOW FLOATING CLIP(HW-230)

TRI-BEAD TAPE SEALER (HW-504)

URETHANE TUBE SEALANT@ CLOSURE ENDS/PANEL RIB& LAPPING CLOSURE TABS TOSEAL ALL VOIDS

OUTSIDE CLOSURE(HW-440) @ 16" PANEL(HW-446) @ 12" PANEL

BACKUP PLATE(HW-7766) @ 16" PANEL(HW-7764) @ 12" PANEL

EAVE STRUT

BUILDING DIM.

BATTENLok® HSPANEL

URETHANE TUBE SEALANT@ CLOSURE ENDS/PANEL RIB& LAPPING CLOSURE TABS TO SEAL ALL VOIDS

¹⁄₄ -14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E) (1) PER RIB

¹⁄₄"-14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E) (1) PER RIB

¹⁄₄"-14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E)(4) PER 16" PANEL(3) PER 12" PANEL

¹⁄₄ -14 x 1¹⁄₄" LONG-LIFESELF-DRILLER W/WASHER(FASTENER #1E)(4) PER 16" PANEL(3) PER 12" PANEL

2" x 2" x 16 GA. BACK UP ANGLE

TRI-BEAD TAPE SEALER (HW-504)TOP AND BOTTOM OF CLOSURE

ALTERNATE DETAILHIGH EAVE SEALANT DETAIL

SCULPTURED HIGH SIDE EAVETRIM (FL-265)

TRI-BEAD TAPE SEALER (HW-504)

SCULPTURED HIGH SIDE EAVETRIM (FL-265)

OUTSIDE CLOSURE

WALL PANEL

OUTSIDE CLOSURE(HW-440) @ 16" PANEL(HW-446) @ 12" PANEL

¹⁄₄ -14 x ⁷⁄₈" LONG-LIFE LAPTEKW/WASHER (FASTENER #4) @ 6" O.C. (DO NOT INSTALL

THRU PANEL RIB)

¹⁄₄"-14 x ⁷⁄₈" LONG-LIFE LAPTEKW/WASHER (FASTENER #4) @ 12" O.C.

1"

2¹⁄₂"

2¹⁄₂"

2"

³⁄₈"

¹⁄₄"-14 x 1¹⁄₄" SELF DRILLER W/O WASHER (FASTENER #1B)

(2) PER CLIP

¹⁄₄"-14 x ⁷⁄₈" LONG LIFE LAPTEKW/WASHER (FASTENER #4) @ 6" O.C.

(DO NOT INSTALL THRU PANEL RIB)

TRI-BEAD TAPE SEALER(HW-504)

HIGH EAVE ENDOF PANEL

7"

�2 -14 x 1¹⁄₄" LONG-LIFE SELF-DRILLERW/WASHER (FASTENER #3)

Page 77: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-75

BattenLok® HS

OPEN FRAMINGPARAPET FLOATING HIGH SIDE EAvE

ZEEPURLIN

BUILDINGDIM.

FEILDSAWCUT

FLEXIBLEMEMBRANE

TRI-BEAD TAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEAD TAPESEALER(HW-504) @ TOP OFCLOSURE& TOP OF

FLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)

MASONRYWALL

PARAPETHIGHEAVETRIM(FL-275)

COUNTERFLASH(FL-341)

URETHANETUBESEALANTCONTINUOUS

14-10x2"DECKSCREW (FASTENER#209)@24"O.C.(PRE-DRILLHOLE)

LOWFLOATINGCLIP(HW-220) ¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER (FASTENER#1E)(1)PERRIB

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(4)PER16"PANEL(3)PER12"PANEL

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

2"

2"7"

³⁄₈"

BACKUP PLATE(HW-7766)@16"PANEL(HW-7764)@12"PANEL

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

¹⁄₄"-14x1¹⁄₄"SELF-DRILLERW/OWASHER(FASTENER#1B)

(2)PERCLIP

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C. (DONOT INSTALLTHRU PANELRIB)

BattenLok® HSPANEL

(NOTBYMETL-SPAN)

Page 78: BattenLok HS - Metl-Span

DETAILS

BHS-76REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

OPEN FRAMINGFIXED vALLEY

BattenLok® HS PANEL

ZEEPURLIN

URETHANETUBESEALANTBETWEENPANELRIBS

VALLEY TRIM(FL-705)

DETAIL "A"

DETAIL "A"

VALLEY SUPPORTPLATE(P-106)

2"

TRIPPLE-BEADTAPESEALER(HW-502)

TRIPPLE-BEADTAPESEALER(HW-502)

FIELDNOTCHPLATE@PURLINASREQUIRED

12-14X1"PANCAKEHEADSELF-DRILLER(FASTENER#12A)(2)PERCONN.@EACHPURLIN12-14X1"PANCAKEHEAD

SELF-DRILLER(FASTENER#12A)@5'-0"O.C.

4¹⁄₂"

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)@3"O.C.(FASTNERMUSTGOTHROUGHTAPESEALER)

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)@3"O.C.(FASTNERMUSTGOTHROUGHTAPESEALER)

URETHANESEALANT

VALLEYENDOF PANEL

BEVELEDEDGEOF ROOF PANEL

URETHANESEALANT MUSTCOMEINCONTACTWITHTAPESEALERTO FORM A WEATHERTIGHT SEAL

PANEL RIB

BattenLok® HS PANEL

Page 79: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-77

BattenLok® HS

OPEN FRAMINGFLOATING HIP

Page 80: BattenLok HS - Metl-Span

DETAILS

BHS-78REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

FIELD HEMMING PANEL END

NOTCHING PANEL END

ENGAGING HEMMING TOOL

PANEL ENGAGEMENT

FORMING OPEN HEM 1 ¹⁄₂"

1 ¹⁄₂"

¹⁄₂"

¹⁄₂"

1"

BattenLok® HSPANEL

FIELDNOTCH

OFFSETCLEAT

1¹⁄₂"

PANELHEMMING TOOL

PANELHEMMING TOOL

PANELHEMMING TOOL

BattenLok® HSPANEL

BattenLok® HSPANEL

Page 81: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-79

BattenLok® HS

WOOD DECKENDLAP

UPPERSWAGEDBattenLok® HS PANEL

SWAGEDENDLAPTAPESEALER(HW-515)

SWAGEDENDLAPTAPESEALER(HW-515)

vIEW “A”

VIEW “A”

BattenLok® HSPANEL(LOWER)

¹⁄₄"-14x⁵⁄₈"LONG-LIFETYPE"B"W/WASHER(FASTENER#46)(5)PER16"PANEL(2)PER12"PANEL

¹⁄₄"-14x⁵⁄₈"LONG-LIFETYPE"B"W/WASHER(FASTENER#46)(5)PER16"PANEL(2)PER12"PANEL

14-10x1"TYPE"A"SELF-TAPPERW/WASHER(FASTENER#18)(2)PERCLIP

BACK-UPPLATE(HW-7766)16"PANEL(HW-7766)12"PANEL

BACK-UPPLATE

FASTENERINSTALLATIONSEQUENCE

TRI-BEADTAPESEALER(HW-504)

TRI-BEADTAPESEALER(HW-504)

LOWFLOATINGCLIP(HW-230)

MOISTUREBARRIER

⁵⁄₈"PLYWOOD(MIN.)

³⁄₈"

123 4

23 4 5 1

BattenLok® HSPANEL(LOWER)

PREPUNCHEDHOLES

UPPERSWAGEDBattenLok® HS PANEL

6"

1¹⁄₂"

4¹⁄₂" (NOT BYMETL-SPAN)

(NOT BYMETL-SPAN)

Page 82: BattenLok HS - Metl-Span

DETAILS

BHS-80REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

WOOD DECKFLOATING EAvE WITH GUTTER

MOISTUREBARRIER(NOTBY METL-SPAN))

⁵⁄₈"PLYWOOD(MIN.)(NOTBYMETL-SPAN)

2"

³⁄₈"PLYWOODSPACER(NOTBYMETL-SPAN))

WALL PANEL

THICKNESS

1'-0" MAX.

BOXGUTTERW/DRIP EDGE

(T-5271)

BUILDINGDIM.

WALL PANEL

EAVEENDOF PANEL

NON-SKINNINGBUTYLSEALANT(HW-549)BETWEENPANELRIBS

EAvE SELANT DETAIL

LOWFLOATINGCLIP (HW-220)

³⁄₈"

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@12"O.C.

WOODBLOCKING(NOTBYMETL-SPAN))

BOXGUTTERW/DRIP EDGE(T-5271)

FIELDNOTCHPANELLEGSANDBENDPANTOFORMOPENHEM

1¹⁄₂"

1¹⁄₂"

1¹⁄₂"

1" ¹⁄₂"¹⁄₂"

14-10x1" TYPE'A'SELF-TAPPERW/WASHER(FASTENER#18)(2)PERCLIP

¹⁄₈"x ³⁄₁₆"POPRIVET(FASTENER#14)(2)PERSTRAP

GUTTERSTRAP (FL-310)@EVERY OTHERRIB

BattenLok® HSPANEL

BattenLok® HSPANEL

BUTYLSEALANT MUSTCOMEINCONTACTWITHTHEDRIP EDGETO FORM AWEATHERTIGHT SEAL

NON-SKINNINGBUTYLSEALANT(HW-549)

BETWEENPANELRIBS

¹⁄₄"-14x1"LONG-LIFE'TYPEAB'SELF-TAPPER

W/WASHER(FASTENER#2B)

Page 83: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-81

BattenLok® HS

WOOD DECKFLOATING EAvE WITH EAvE TRIM

BUTYLSEALANT MUSTCOMEINCONTACTWITHTHEDRIP EDGETO FORM AWEATHERTIGHT SEAL

EAVEENDOF PANEL

NON-SKINNINGBUTYLSEALANT (HW-549)BETWEENPANELRIBS

BattenLok® HSPANEL

EAVETRIMW/DRIP EDGE(T-5271)

FIELDNOTCHPANELLEGSANDBENDPANTOFORMOPENHEM

1¹⁄₂"

1¹⁄₂"

1¹⁄₂"

1" ¹⁄₂"¹⁄₂"

MOISTUREBARRIER(NOTBYMETL-SPAN))

2"12-11X1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@12"O.C.

WALL PANEL

THICKNESS

1'-0" MAX.

BUILDINGDIM.

WALL PANEL

OUTSIDECLOSURE

LOWFLOATINGCLIP(HW-220)

³⁄₈"

WOODBLOCKING(NOTBYMETL-SPAN))

14-10x1"TYPE'A'SELF-TAPPERW/WASHER(FASTENER#18)(2)PERCLIP

EAVETRIMW/DRIP EDGE(T-5151)

BattenLok® HSPANEL

NON-SKINNINGBUTYLSEALANT (HW-549)

BETWEENPANELRIBS

¹⁄₄"-14x1"LONG-LIFE'TYPEAB'SELF-TAPPER

W/WASHER(FASTENER#2B)

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER

(FASTENER#4)@12"O.C.

EAvE SELANT DETAIL

⁵⁄₈"PLYWOOD(MIN.)(NOTBYMETL-SPAN))

CONT. ³⁄₈"PLYWOODSPACER(NOTBYMETL-SPAN))

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@12"O.C.

Page 84: BattenLok HS - Metl-Span

DETAILS

BHS-82REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

WOOD DECKFIXED RIDGE

MOISTUREBARRIER(NOTBYMETL-SPAN))

TRI-BEADTAPESEALER(HW-504)

TRI-BEADTAPESEALER(HW-504)CONT. ACROSSPANEL

2"

RIDGETRIM(FL-209)

³⁄₈"

³⁄₈"PLYWOODSPACER(NOTBYMETL-SPAN))

⁵⁄₈"PLYWOOD(MIN.(NOTBYMETL-SPAN))

TRI-BEADTAPESEALER(HW-504)

RIDGEENDOF PANEL

3"

BattenLok® HSPANEL

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#1E)(1)PERRIB

2"

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6”O.C.(DONOT INSTALLTHRU PANELRIB)

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

14-10x1"TYPE'A'SELF-TAPPERW/WASHER(FASTENER#18)(4)PER16"PANEL(3)PER12"PANEL

Page 85: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-83

BattenLok® HS

WOOD DECKFIXED vENTED RIDGE

TRI-BEADTAPESEALER(HW-504)

RIDGEENDOF PANEL

3"

PERFORATEDVENTDRIP(FL-254)

URETHANESEALANT(HW-504)

PERFORATEDVENTDRIP(FL-254)

3”LAP(MIN.)

MOISTUREBARRIER(NOTBYMETL-SPAN)

TRI-BEADTAPESEALER(HW-504)

TRI-BEADTAPESEALER(HW-504)CONT. ACROSSPANEL

2" RIDGETRIM(FL-300)

³⁄₈"PLYWOODSPACER(NOTBYMETL-SPAN)

⁵⁄₈"PLYWOOD(MIN.(NOTBYMETL-SPAN)

BattenLok® HSPANEL

¹⁄₄"-14x1¹⁄₄"LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#1E)(1)PERRIB

2" ¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6”O.C.(DONOT INSTALLTHRU PANELRIB)

¹⁄₄"-14x⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

14-10x1"TYPE'A'SELF-TAPPERW/WASHER(FASTENER#18)(4)PER16"PANEL(3)PER12"PANEL

Page 86: BattenLok HS - Metl-Span

DETAILS

BHS-84REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

WOOD DECKRAKE

⁵⁄₈"PLYWOOD(MIN.)(NOTBYMETL-SPAN)

BattenLok® HS PANEL

TRI-BEAD TAPESEALER(HW-504)

¹⁄₈"x³⁄₁₆"POP RIVET(FASTENER#14)

@12"O.C.

LOWFLOATINGCLIP(HW-220)

HIGHWINDPARAPETRAKECLEAT (F-292)

CONTINUOUSCLEAT(FL-338)

OUTSIDECLOSURE

WALL PANEL

BOXRAKETRIM

LOWRAKESUPPORT ANGLE(HW-7712)

WOODBLOCKING(NOTBYMETL-SPAN)

2x4x16GA.ANGLE

¹⁄₄"-14x1¹⁄₄"SHOULDERTEK®2SELF-DRILLER(FASTENER#5) @24"O.C.(CENTERINSLOT)

1¹⁄₄"

BUILDINGDIM.

¹⁄₄"-14x ⁷⁄₈"LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.

FIELDCUT&BENDUP2"PANELLEGASREQUIREDWHENENDINGOFFMODULE

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@24"O.C.(PRE-DRILL ANGLE)

¹⁄₄"-14x1"LONG-LIFE'TYPEAB'SELF-TAPPER

W/WASHER(FASTENER#2B)

MOISTUREBARRIER(NOTBYMETL-SPAN)

¹⁄₄"-14x1¹⁄₄"LONG-LIFE SELFDRILLERW/WASHER(FASTENER#1E)@24"O.C.

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)(2)PERCLIP

Page 87: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-85

BattenLok® HS

WOOD DECKPARAPET RAKE

"PLYWOOD(MIN.)(NOTBYMETL-SPAN)

MOISTUREBARRIER(NOTBYMETL-SPAN)

"

1 "

BUILDINGDIM.

FEILDSAWCUT

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

MASONRY WALL(NOTBY METL-SPAN)

LOWRAKESUPPORT ANGLE(HW-7712)

FIELDCUT&BENDUP2"PANELLEGASREQ’DWHEN

ENDINGOFFMODULE

(MIN.)

14-10x2"DECKSCREW (FASTENER#209)@24"O.C.

(PRE-DRILLHOLE)

"-14x1 "SHOULDERTEK® 2SELF-DRILLER(FASTENER#5)@24"O.C.(CENTERINSLOT)

BattenLok® HS PANEL

LOWFLOATINGCLIP(HW-220)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)@24"O.C.

HIGHWINDPARAPETRAKECLEAT (F-292)

PARAPETRAKETRIM(FL-285)

COUNTERFLASH(FL-341)

URETHANETUBESEALANTCONTINUOUS

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@24"O.C.(PRE-DRILL ANGLE)

WOODBLOCKING(NOTBY METL-SPAN)

2x4x16GAUGEANGLE

FLEXIBLEMEMBRANE

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)(2)PERCLIP

Page 88: BattenLok HS - Metl-Span

DETAILS

BHS-86REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

WOOD DECKFIXED HIGH SIDE EAvE

MOISTUREBARRIER(NOTBYMETL-SPAN)

"PLYWOOD(MIN.)(NOTBYMETL-SPAN)

"PLYWOODSPACER(NOTBYMETL-SPAN)

TRI-BEADTAPESEALER(HW-504)

TRI-BEADTAPESEALER(HW-504)

"-14x "LONG-LIFELAP TEK®W/WASHER(FASTENER#4)@12"O.C.

"-14x1 "LONG-LIFESELFDRILLERW/WASHER(FASTENER#1E)(1)PERRIB

BOXHIGHSIDEEAVETRIM(FL-331)

BUILDINGDIM.

HIGH EAvE SEALANT DETAIL

WALL PANEL

OUTSIDECLOSURE

"

WOODBLOCKING(NOTBYMETL-SPAN)

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

TRI-BEADTAPESEALER(HW-504)

RIDGEENDOF PANEL

7"

BattenLok® HSPANEL

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.(DONOT INSTALLTHRU PANELRIB)

"-14x1"LONG-LIFE'TYPEAB'SELF-TAPPERW/WASHER(FASTENER#2B)

14-10"x1"TYPE'A'SELF-TAPPERW/WASHER(FASTENER#18)(4)PER16"PANEL(3)PER12"PANEL

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

2" 2"

Page 89: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-87

BattenLok® HS

WOOD DECKPARAPET FIXED HIGH SIDE EAvE

2"

TRI-BEADTAPESEALER(HW-504)

HIGHEAVEENDOF PANEL

7"

BattenLok® HS PANEL

BUILDINGDIM.

FIELDSAWCUT

FLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504) @ TOP OFCLOSURE&TOP OF

FLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)

MASONRY WALL(NOTBY METL-SPAN)

PARAPETHIGHEAVETRIM(FL-276)

COUNTERFLASH(FL341)

URETHANETUBESEALANTCONTINUOUS

14-10x2"DECKSCREW (FASTENER#209)@24"O.C.(PRE-DRILLHOLE)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(1)PERRIB

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

2"OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.(DONOT INSTALLTHRU PANELRIB)

14-10x1"TYPE'A'SELF-TAPPERW/WASHER

(FASTENER#18)(4)PER16"PANEL(3)PER12"PANEL

MOISTUREBARRIER(NOTBY METL-SPAN)

"PLYWOOD(MIN.)(NOTBY METL-SPAN)

"PLYWOODSPACER(NOTBY METL-SPAN)

HIGH EAvE SEALANT DETAIL

Page 90: BattenLok HS - Metl-Span

DETAILS

BHS-88REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

WOOD DECKFLOATING vALLEY

OFFSETCLEAT(FL-337)

FIELDNOTCHPANELLEGSANDBENDPANTOFORMOPENHEM

1 "

1 "

1 "

1" ""

4 "

TRI-BEADTAPESEALER(HW-504)

2"

1'-0" MAX.

"

LOWFLOATINGCLIP(HW-220)

NON-SKINNINGBUTYL SEALANT(HW-549)

BETWEENPANELRIBS

VALLEY TRIM(FL-707)

OFFSETCLEAT(FL-337)

"

NOTE: DO NOT USE THIS DETAIL ON ROOF SLOPES LESS THAN 3:12

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)

@5'-0"O.C. MOISTUREBARRIER(NOTBYMETL-SPAN)

"PLYWOOD(MIN.)(NOTBYMETL-SPAN)

BattenLok® HSPANEL

BUTYLSEALANT MUST COMEIN CONTACT WITH THEOFFSETCLEATTO FORM A WEATHERTIGHTSEAL

VALLEY ENDOF PANEL

BattenLok® HSPANEL

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)@12"O.C.(FASTENERMUSTGOTHROUGHTAPESEALER)

NON-SKINNINGBUTYL SEALANT(HW-549)BETWEENPANELRIBS

12-11x1"PANCAKEHEADSELF-TAPPER(FASTENER#13A)(2)PERCLIP

Page 91: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-89

BattenLok® HS

WOOD DECKFIXED HIP

MOISTUREBARRIER(NOTBYMETL-SPAN)

TRI-BEADTAPESEALER(HW-504)

RIDGE/HIP TRIM(FL-209)

"

ZEECLOSURE(FL-361)(FIELDCUTTOLENGTH&BEVELCUT TO FIT PANEL)

URETHANETUBESEALANT@CLOSUREENDS

"PLYWOODSPACER(NOTBYMETL-SPAN)

"PLYWOOD(MIN.)(NOT BYMETL-SPAN)

TRI-BEADTAPESEALER(HW-504)

HIP ENDOF PANEL

3"

BattenLok® HSPANEL

2" 2"

14-10x1"TYPE“A”SELF-TAPPERW/WASHER(FASTENER#18)@6"O.C.

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4) @12"O.C.

TRI-BEADTAPESEALER(HW-504)CONTINUEDACCROSSPANEL

Page 92: BattenLok HS - Metl-Span

DETAILS

BHS-90REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKENDLAP

VIEW“A”

SWAGEDENDLAPTAPESEALER(HW-515)

"-14x "LONG-LIFETYPE“B”SELF-TAPPER

W/WASHER(FASTENER#46)(5)PER16"PANEL(4)PER12"PANEL

"-14x "LONG-LIFETYPE“B”SELF-TAPPER

W/WASHER(FASTENER#46)(5)PER16"PANEL(4)PER12"PANEL

BattenLok® HSPANEL(LOWER)

UPPERSWAGEDBattenLok® HSPANEL

1 "

4 "

6"

10"

DECKSCREW(2)PERCLIP(MIN. "PENETRATION

INTOMETALDECK)

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION

LOWFLOATINGCLIP(HW-220)

BEARINGPLATE(HW-7500)

METALDECK(MIN.22GA.)(NOTBYMETL-SPAN)

"

UPPERSWAGEDBattenLok® HSPANEL

LOWERBattenLok® HSPANEL

PREPUNCHEDHOLES(16"PANELONLY)

VIEW“A”

BACK-UPPLATE(HW-7766)16”PANEL(HW-7764)12”PANEL

SWAGEDENDLAPTAPESEALER(HW-515)

TRI-BEADTAPESEALER(HW-504)@16"PANEL

TRIPLE-BEADTAPESEALER(HW-502)@12"PANEL

TRI-BEADTAPESEALER(HW-504)@16"PANEL

TRIPLE-BEADTAPESEALER(HW-502)@12"PANEL

BACK-UPPLATE(HW-7766)16"PANEL(HW-7764)12"PANEL

FASTENERINSTALLATIONSEQUENCE

12"

16"

2 3 4 1

2 3 4 5 1

(NOTBYMETL-SPAN)

Page 93: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-91

BattenLok® HS

RIGID INSULATION OvER METAL DECKFLOATING EAvE WITH GUTTER

BUTYLSEALANT MUSTCOMEINCONTACT WITHDRIP EDGE TO FORM AWEATHERTIGHTSEAL

EAVEENDOF PANEL

BattenLok® HSPANEL

NON-SKINNINGBUTYLSEALANT (HW-549)BETWEENPANELRIBS

BOXGUTTERW/DRIP EDGE(T-5271)

PANEL ENGAGMENT DETAIL

FIELDNOTCHPANELLEGS ANDBENDPANTOFORMOPENHEM1 "

1 "

1 "1"

""

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

1'-0" MAX.

BOXGUTTERW/DRIP EDGE

(T-5271)

BUILDINGDIM.

WALL PANEL

LOWFLOATINGCLIP(HW-220)

BEARINGPLATE(HW-7500)

DECKSCREW(2)PERCLIP(MIN. "PENETRATIONINTOMETALDECK)

"

12-14x1"PANCAKEHEADSELF-DRILLER (FASTENER#12A)@12"O.C.

"x "POPRIVET(FASTENER#14)(2)PERSTRAP

GUTTERSTRAP(FL-310)@EVEROTHERRIB

BattenLok® HSPANEL

2"

"

WALL PANEL

THICKNESS

NON-SKINNINGBUTYLSEALANT (HW-549)

BETWEENPANELRIBS

12x24x1 "LONG-LIFETEK4.5W/WASHER

(FASTENER#78)

STRUCTURALANGLE(NOTBYMETL-SPAN)

3"x5"x14GA.BENTPLATE(HOLDTOP OFPLATE "ABOVETOPOFRIGIDINSULATION)

12-24x1 "PANHEADTEK4.5SELF-DRILLER(FASTENER#16)@12"O.C.

METALDECK(NOTBYMETL-SPAN)

Page 94: BattenLok HS - Metl-Span

DETAILS

BHS-92REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKFLOATING EAvE WITH EAvE TRIM

BUTYLSEALANT MUSTCOMEINCONTACTWITHTHEDRIP EDGETO FORM AWEATHERTIGHT SEAL

EAVEENDOF PANEL

BattenLok® HSPANEL

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

BUILDINGDIM.

WALL PANEL

BEARINGPLATE(HW-7500)

DECKSCREW(2)PERCLIP(MIN. "PENETRATIONINTOMETALDECK)

"

12-14x1"PANCAKEHEADSELF-DRILLER(FASTENER#12A)@12"O.C.

BattenLok® HSPANEL

2"

"NON-SKINNINGBUTYLSEALANT(HW-549)

BETWEENPANELRIBS

12x24x1"LONG-LIFETEK4.5W/WASHER

(FASTENER#78)

STRUCTURAL ANGLE(NOTBYMETL-SPAN)

3"x5"x14GA.BENTPLATE(HOLDTOP OFPLATE "ABOVETOPOFRIGIDINSULATION)

12-24x1 "PANHEADTEK4.5SELF-DRILLER(FASTENER#16)@12"O.C.

METALDECK(NOTBYMETL-SPAN)

LOWFLOATINGCLIP(HW-220)

"-14x "LONG-LIFELAPTEKW/WASHER

(FASTENER#4)@12"O.C.

OUTSIDECLOSURE

EAVETRIMW/DRIP EDGE(T-5151)

1'-0"MAX.

BOXGUTTERW/DRIP EDGE(T-5271)

PANEL ENGAGMENT DETAIL

FIELDNOTCHPANELLEGSANDBENDPANTOFORMOPENHEM1 "

1 "

1 "1"

""

NON-SKINNINGBUTYLSEALANT(HW-549)BETWEENPANELRIBS

Page 95: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-93

BattenLok® HS

RIGID INSULATION OvER METAL DECKFIXED RIDGE

TRI-BEADTAPESEALER(HW-504)

RIDGEENDOF PANEL

3"

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

DECKSCREW @12"O.C.(MIN. "PENETRATIONINTOMETALDECK)

TRI-BEADTAPESEALER(HW-504)

2"

RIDGETRIM(FL-209)

"

BattenLok® HSPANEL

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#1E)(1)PERRIB

2"

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6”O.C.(DONOT INSTALLTHRU PANELRIB)

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

RIDGE/HIP SUPPORT PLATE(P-145)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(4)PER16"PANEL(3)PER12"PANEL

TRI-BEADTAPESEALER(HW-504)

Page 96: BattenLok HS - Metl-Span

DETAILS

BHS-94REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKFIXED vENTED RIDGE

TRI-BEAD TAPESEALER(HW-504)

RIDGEENDOF PANEL

3"

URETHANESEALANT(HW-504)

PERFORATEDVENT DRIP(FL-254)

1"LAP(MIN.)

PERFORATEDVENT DRIP(FL-254)

TRI-BEAD TAPESEALER(HW-504)

2" RIDGE TRIM(FL-300)

BattenLok® HSPANEL

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#1E)(1)PERRIB

2" "-14x "LONGLIFELAPTEKW/WASHER(FASTENER#4)@6”O.C.(DONOT INSTALLTHRU PANELRIB)

"-14x "LONGLIFELAPTEKW/WASHER(FASTENER#4) @6”O.C.

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURE TABSTOSEAL ALLVOIDS

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-446)@12"PANEL

TRI-BEAD TAPESEALER(HW-504)

LOWMID-SLOPEFIXEDPLATE(HW-504)

1"MIN.

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(4)PER16"PANEL(3)PER12"PANEL

DECKSCREW@12"O.C.(MIN. "PENETRATIONINTOMETALDECK)

"

Page 97: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-95

BattenLok® HS

RIGID INSULATION OvER METAL DECKRAKE

TRI-BEAD TAPESEALER(HW-504)

-14x1 "SHOULDERTEK®2SELF-DRILLER(FASTENER#5) @24"O.C(CENTERINSLOT)

"

CONTINUOUSCLEAT(FL-338)

WALL PANEL

1 "BUILDINGDIM.

DECKSCREW(2)PER CLIP(MIN. "PENETRATIONINTOMETALDECK)

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

STRUCTURALANGLE(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

2x4x16GA. ANGLEOUTSIDECLOSURE

BOXRAKETRIM

LOWRAKESUPPORT ANGLE(HW-7712)

12-24x1 "PANHEADTEK4.5SELF-DRILLER

(FASTENER#16)@12"O.C.

12-24x1 "LONG-LIFETEK4.5W/WASHER

(FASTENER#78)

"x "POP RIVET(FASTENER#14)

@12"O.C.

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)@24"O.C.

HIGHWINDPARAPETRAKECLEAT (F-292)

FIELDCUT&BENDUP2"PANELLEGASREQUIREDWHENENDINGOFFMODULE

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.

BattenLok® HS PANEL

LOWFLOATINGCLIP(HW-220)BEARINGPLATE(HW-7500)

Page 98: BattenLok HS - Metl-Span

DETAILS

BHS-96REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKPARAPET RAKE

VAPORBARRIER(NOTBYMETL-SPAN)

"

1 "FEILDSAWCUT

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

LOWRAKESUPPORT ANGLE(HW-7712)

FIELDCUT&BENDUP2"PANELLEGASREQ’DWHEN

ENDINGOFFMODULE

(MIN.)

14-10x2"DECKSCREW(FASTENER#209)@24"O.C.

(PRE-DRILLHOLE)

DECKSCREW@24"O.C.(MIN. "PENETRATION INTOMETALDECK)

BattenLok® HS PANEL

LOWFLOATINGCLIP(HW-220)

"-14x1 "LONG-LIFE SELF-DRILLERW/WASHER(FASTENER#1E)@24"O.C.

HIGHWINDPARAPETRAKECLEAT (F-292)

PARAPETRAKETRIM(FL-285)

COUNTERFLASH(FL-341)

URETHANETUBESEALANTCONTINUOUS

RIGIDINSULATION(NOTBY METL-SPAN)

STRUCTURAL ANGLE(NOTBY METL-SPAN)

BEARINGPLATE(HW7500)@24"O.C.

FLEXIBLEMEMBRANE

METALDECK(NOTBY METL-SPAN)

"-14x1 "SHOULDERTEK®2SELF-DRILLER(FASTENER#5)

@24"O.C

BEARINGPLATE(HW-7500)

DECKSCREW@(2)PERCLIP(MIN. "PENETRATIONINTOMETALDECK)

Page 99: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-97

BattenLok® HS

RIGID INSULATION OvER METAL DECKFIXED HIGH SIDE EAvE

BUILDINGDIM.

BattenLok® HSPANEL

2" 2"

"

TRI-BEADTAPESEALER(HW-504)

TRI-BEADTAPESEALER(HW-504)

"-14x1 "LONG-LIFESELFDRILLERW/WASHER(FASTENER#1E)(1)PERRIB

BOXHIGHSIDEEAVETRIM(FL-331)

WALL PANEL

OUTSIDECLOSURE

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-440)@12"PANEL

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.(DONOT INSTALL THRU PANELRIB)

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@12"O.C.

12-24x1 "LONG-LIFETEK4.5W/WASHER(FASTENER#78)

LOWFIXEDEAVEPLATE(HW-7600)

DECKSCREW@12"O.C. (MIN. "PENETRATION

INTOMETALDECK)

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER

(FASTENER#1E)(4)PER16"PANEL(3)PER12"PANEL

STURCTURAL ANGLE(NOTBYMETL-SPAN)

TRI-BEADTAPESEALER(HW-504)

HIGHEAVEENDOF PANEL

7"

HIGH EAvE SEALANT DETAIL

Page 100: BattenLok HS - Metl-Span

DETAILS

BHS-98REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKPARAPET FIXED HIGH SIDE EAvE

TRI-BEADTAPESEALER(HW-504)

RIDGEENDOF PANEL

7"

BattenLok® HS PANEL

FIELDSAWCUT

HIGH EAvE SEALANT DETAIL

FLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)EA.SIDEOFFLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504) @ TOP OFCLOSURE&TOP OF

FLEXIBLEMEMBRANE

TRI-BEADTAPESEALER(HW-504)

MASONRY WALL(NOTBY METL-SPAN)

PARAPETHIGHEAVETRIM(FL-276)

COUNTERFLASH(FL-341)

URETHANETUBESEALANTCONTINUOUS

14-10x2"DECKSCREW(FASTENER#209)@24"O.C.(PRE-DRILLHOLE)

"-14x1 "LONG-LIFE SELF-DRILLERW/WASHER(FASTENER#1E)(1)PERRIB

URETHANETUBESEALANT@CLOSUREENDS/PANELRIB&LAPPINGCLOSURETABSTOSEAL ALLVOIDS

2"

"-14x "LONG-LIFELAPTEKW/WASHER(FASTENER#4)@6"O.C.(DONOT INSTALLTHRU PANELRIB)

"

VAPORBARRIER(NOTBY METL-SPAN)

RIGIDINSULATION(NOTBY METL-SPAN)

METALDECK(NOTBY METL-SPAN)

DECKSCREW@12"O.C.(MIN. "PENETRATION

INTOMETALDECK)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER(FASTENER#1E)(4)PER16"PANEL(3)PER12"PANEL

OUTSIDECLOSURE(HW-440)@16"PANEL(HW-440)@12"PANEL

LOWMID-SLOPEFIXEDPLATE(HW-7631)

Page 101: BattenLok HS - Metl-Span

DETAILS

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-99

BattenLok® HS

RIGID INSULATION OvER METAL DECKFLOATING vALLEY

OFFSETCLEAT(FL-337)

FIELDNOTCHPANELLEGSANDBENDPANTOFORMOPENHEM

1 "

1 "

1 "

1" ""

4 "TRI-BEADTAPESEALER(HW-504)

2"

"

1'-0"MAX.LOWFLOATINGCLIP(HW-220)

BEARINGPLATE(HW-7500)

NON-SKINNINGBUTYLSEALANT(HW-549)

BETWEENPANELRIBS

NON-SINNINGBUTYLSEALANT(HW-549)BETWEENPANELRIBS

VALLEY TRIM(FL-707)

OFFSETCLEAT(FL-337)

"

VALLEY SUPPORTPLATE(P-105)

BUTYLSEALANT MUSTCOMEINCONTACT WITHTHEOFFSETCLEAT TO FORM AWEATHERTIGHTSEAL

VALLEY ENDOF PANEL

BattenLok® HSPANEL

BattenLok® HSPANEL

12-14X1"PANCAKEHEADSELF-DRILLER(FASTENER#12A)@12"O.C.(FASTENERMUSTGOTHROUGHTAPESEALER)

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

DECKSCREW(2)PERCLIP(MIN. "PENETRATION

INTOMETALDECK)

DECKSCREW@12"O.C.(MIN. "PENETRATION

INTOMETALDECK)

NOTE: DO NOT USE THIS DETAIL ON ROOF SLOPES LESS THAN 3:12

Page 102: BattenLok HS - Metl-Span

DETAILS

BHS-100REV01.01SEEmetlspan.comFORCURRENTINFORMATIONSUBJECTTOCHANGEWITHOUTNOTICE

BattenLok® HS

RIGID INSULATION OvER METAL DECKFIXED HIP

TRI-BEADTAPESEALER(HW-504)

HIPENDOF PANEL

3"

TRI-BEADTAPESEALER(HW-504)

RIDGE/HIP TRIM(FL-209)

ZEECLOSURE(FL-361)(FIELDCUTTOLENGTH&BEVELCUT TO FIT PANEL)

URETHANETUBESEALANT@CLOSUREENDS( "BEADMIN.)

BattenLok® HSPANEL

2" 2""-14x "LONG-LIFELAPTEK

W/WASHER(FASTENER#4)@6"O.C.(DONOT INSTALL THRU PANELRIB)

TRI-BEAD TAPESEALER(HW-504)CONTINUEDACROSSPANEL

"

HIP SUPPORTPLATE(P-145)

VAPORBARRIER(NOTBYMETL-SPAN)

RIGIDINSULATION(NOTBYMETL-SPAN)

METALDECK(NOTBYMETL-SPAN)

DECKSCREW@12"O.C.(MIN. "PENETRA TIONINTOMETALDECK)

"-14x1 "LONG-LIFESELF-DRILLERW/WASHER (FASTENER#1E)@6"O.C.

Page 103: BattenLok HS - Metl-Span

SUBJECTTOCHANGEWITHOUTNOTICESEEmetlspanFORCURRENTINFORMATIONREV01.01BHS-101

BattenLok® HS

NOTES

Page 104: BattenLok HS - Metl-Span

1720 lakepointe Drive suite #101 lewisville, Texas 75057

toll-free: 877.585.9969 | email: [email protected] Web: metlspan.com