IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 5 avenue ® c FAVC SUSPENDED FAVCS SURFACE MOUNT FAVCS-SM WALL MOUNT FAVCW KEY WEIGHTS FAVCS 4' - 9LBS | 8' - 18LBS FAVCW 4' - 13LBS | 8' - 26LBS POWER OFF POWER ON Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. ATTENTION ADDITIONAL INSTRUCTIONS LEVEL UNIVERSAL SUSPENSION SYSTEM - SHIPS SEPARATELY U- INDIVIDUAL S- START OF RUN U- INDIVIDUAL S- START OF RUN U- INDIVIDUAL S- START OF RUN I- INTERMEDIATE E- END OF RUN I- INTERMEDIATE E- END OF RUN I- INTERMEDIATE E- END OF RUN USE SINGLE DEVICE COVER OR SINGLE GANG HANDY BOX (BY OTHERS) MOUNTING HARDWARE (BY OTHERS) J-BOX (BY OTHERS)

Upload: others

Post on 12-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: avenue - Focal Point Lights · FAVC SUSPENDED favcS SURfacE MOUNT favcS-SM WaLL MOUNT favcW kEy WEighTS favcS 4' - 9lbs | 8' - 18lbs favcW 4' - 13lbs | 8' - 26lbs POWER Off POWER

IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 5

avenue® c

FAVC

SUSPENDED favcS

SURfacE MOUNT favcS-SM

WaLL MOUNT favcW

kEy

WEighTS

favcS

4' - 9lbs | 8' - 18lbs

favcW

4' - 13lbs | 8' - 26lbs

POWER Off

POWER ON

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

aTTENTiON

aDDiTiONaL iNSTRUcTiONS

LEvELUNivERSaL SUSPENSiON SySTEM - ShiPS SEPaRaTELy

U- iNDiviDUaL

S- STaRT Of RUN

U- iNDiviDUaL

S- STaRT Of RUN

U- iNDiviDUaL

S- STaRT Of RUN

i- iNTERMEDiaTE

E- END Of RUN

i- iNTERMEDiaTE

E- END Of RUN

i- iNTERMEDiaTE

E- END Of RUN

USE SiNgLE DEvicE cOvER OR SiNgLE gaNg haNDy bOx (by OThERS)MOUNTiNg haRDWaRE (by OThERS)

j-bOx (by OThERS)

Page 2: avenue - Focal Point Lights · FAVC SUSPENDED favcS SURfacE MOUNT favcS-SM WaLL MOUNT favcW kEy WEighTS favcS 4' - 9lbs | 8' - 18lbs favcW 4' - 13lbs | 8' - 26lbs POWER Off POWER

IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 5

LENS ONLy

FoLLow FoCAL PoINT INSTRuCTIoNS FoR

uNIVERSAL SuSPENSIoN SySTEm ASSEmbLy.

SEE IS0166

houSINg/uNIT X

4' individual/start 47.5"

4' intermediate/end 48.0"

8' individual/start 95.5"

8' intermediate/end 96.0"

1

324

75 26

8 29

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

SuSPENDED (FAVCS)

22X

MakE ELEcTRicaL cONNEcTiONS

LENS ONLy

Page 3: avenue - Focal Point Lights · FAVC SUSPENDED favcS SURfacE MOUNT favcS-SM WaLL MOUNT favcW kEy WEighTS favcS 4' - 9lbs | 8' - 18lbs favcW 4' - 13lbs | 8' - 26lbs POWER Off POWER

IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 5

LENS ONLy

LENS ONLy 312

64 25

978

10

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

SuRFACE mouNT (FAVCS-Sm)

MakE ELEcTRicaL cONNEcTiONS

SECURE HOUSING TO STRUCTURE ABOVE. (HARDWARE BY OTHERS.)

Page 4: avenue - Focal Point Lights · FAVC SUSPENDED favcS SURfacE MOUNT favcS-SM WaLL MOUNT favcW kEy WEighTS favcS 4' - 9lbs | 8' - 18lbs favcW 4' - 13lbs | 8' - 26lbs POWER Off POWER

IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 5

LENS ONLy

fEED LOcaTiONS

21

3 4

25

8

6

79

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

wALL mouNT (FAVCw)

3' & 6' housings

all housing lengths

center cutout on j-box

LOCATE J-BOX CENTER & INSTALL (J-BOX BY OTHERS)

LOCATE MOUNTING RAIL

INSTALL REMAINING RAILS. REMOVE END SECTION FROM LAST RAIL IN RUN.

18"

4' & 8' housings

luminaire outline

luminaire outline

luminaire outline

24"

3.33"3.33"

3.33"

3.70"

3.70"

3.70"

MakE ELEcTRicaL cONNEcTiONS

A

B

C

(FASTENERS BY OTHERS)

(FASTENERS BY OTHERS)

Page 5: avenue - Focal Point Lights · FAVC SUSPENDED favcS SURfacE MOUNT favcS-SM WaLL MOUNT favcW kEy WEighTS favcS 4' - 9lbs | 8' - 18lbs favcW 4' - 13lbs | 8' - 26lbs POWER Off POWER

Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.

IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 5 of 5

LENS ONLy

14

12

213

bALLAST SERVICE (SuRFACE mouNT ShowN)

wALL mouNT (FAVCw) - CoNTINuED

LENS ONLy2

4

13

11

MakE ELEcTRicaL cONNEcTiONS

210