av100 - eugene school district legend description manufacturer part number cs x control \...

18
REVISIONS: PROJECT #: ISSUE DATE: PRINTED ON: 2014 PIVOT ARCHITECTURE FROM FILE: C 6/3/2015 5:17:15 PM C:\Pivot_Architecture\Revit_2015\1337_RRES_Arch_Bldg_15_bob.rvt AV GENERAL EUGENE SCHOOL DISTRICT 4J RIVER ROAD / EL CAMINO DEL RIO ELEMENTARY SCHOOL 1337.00 02.12.2016 AV100 120 WEST HILLIARD AVENUE, EUGENE, OREGON 97404 LISTEN ACOUSTICS 1001 SW 5TH AVE SUITE 1100 PORTLAND, or 97204 503-241-5255 BID SET

Upload: doanphuc

Post on 15-Mar-2019

259 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

RE

VIS

IO

NS

:P

RO

JE

CT

#:

IS

SU

E D

AT

E:

PR

IN

TE

D O

N:

20

14

P

IV

OT

A

RC

HIT

EC

TU

RE

FR

OM

F

IL

E:

C

6/3

/2

01

5 5

:1

7:1

5 P

MC

:\P

ivo

t_

Arch

ite

ctu

re

\R

evit_

20

15

\1

33

7_

RR

ES

_A

rch

_B

ld

g_

15

_b

ob

.rvt

AV

G

EN

ER

AL

EU

GE

NE

S

CH

OO

L D

IS

TR

IC

T 4

J

RIV

ER

R

OA

D / E

L C

AM

IN

O D

EL R

IO

E

LE

ME

NT

AR

Y S

CH

OO

L

13

37

.0

0

02

.1

2.2

01

6

AV100

12

0 W

ES

T H

IL

LIA

RD

A

VE

NU

E, E

UG

EN

E, O

RE

GO

N 9

74

04

LIS

TE

N A

CO

US

TIC

S

1001

SW

5TH

AVE

SUIT

E 11

00PO

RTLA

ND, o

r 972

0450

3-24

1-52

55

BID

S

ET

AutoCAD SHX Text
6. ISOLATE EACH RACK FROM THE OTHER RACKS, BOLT TOGETHER WITH PLASTIC BOLTS
AutoCAD SHX Text
#12 FOR %%UEACH%%U DEVICE OR RECEPTACLE/PLUG STRIP
AutoCAD SHX Text
RACK COMMON GROUND POINT
AutoCAD SHX Text
3. DO NOT CONNECT ELECTRICAL BOX OR CONDUIT TO PIN #1 OR CABLE SHIELD AT RECEPTACLES.
AutoCAD SHX Text
4. ISOLATED GROUND RECEPTACLES TYPICAL FOR ALL POWER RECEPTACLES IN SOUND EQUIPMENT AREAS.
AutoCAD SHX Text
5. ISOLATE ALL CONDUIT FROM EQUIPMENT RACKS USING PLASTIC BUSHINGS OR OTHER MEANS.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
%%UPOWER GROUNDING DETAIL
AutoCAD SHX Text
1
AutoCAD SHX Text
2. DO NOT BUS GROUND LINES EXCEPT AS SHOWN.
AutoCAD SHX Text
GROUND RECEPTACLES
AutoCAD SHX Text
USE ONLY ISOLATED
AutoCAD SHX Text
WALL RECEPTACLES
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
1. ALL GROUND LINES MEET AT ONE POINT WITHIN EACH EQUIPMENT RACK.
AutoCAD SHX Text
7. ALL GROUND CONDUCTORS INSULATED COPPER OF GAUGE INDICATED.
AutoCAD SHX Text
REPEAT FOR EACH RACK
AutoCAD SHX Text
TO MAIN SERVICE GROUND
AutoCAD SHX Text
RACK GROUND
AutoCAD SHX Text
SUB-PANEL
AutoCAD SHX Text
BUS
AutoCAD SHX Text
FLEX
AutoCAD SHX Text
BUSHING
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
PLASTIC
AutoCAD SHX Text
POWER
AutoCAD SHX Text
SOUND ONLY
AutoCAD SHX Text
CHASSIS GROUND
AutoCAD SHX Text
COMMON CIRCUIT AND
AutoCAD SHX Text
COMMON CIRCUIT
AutoCAD SHX Text
UNUSED
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
CHASSIS
AutoCAD SHX Text
GROUND ONLY
AutoCAD SHX Text
CHASSIS GROUND
AutoCAD SHX Text
COMMON CIRCUIT AND
AutoCAD SHX Text
AUDIO EQUIPMENT RACK
AutoCAD SHX Text
CONDUITS
AutoCAD SHX Text
AUDIO SIGNAL
AutoCAD SHX Text
FLEX
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
PLASTIC
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
BUSHING
AutoCAD SHX Text
GROUND RECEPTACLES
AutoCAD SHX Text
RACK RECEPTACLES
AutoCAD SHX Text
USE ONLY ISOLATED
AutoCAD SHX Text
3 CONDUCTOR CORD
AutoCAD SHX Text
2 CONDUCTOR CORD
AutoCAD SHX Text
3 CONDUCTOR CORD
AutoCAD SHX Text
CHASSIS FROM SIGNAL GROUND
AutoCAD SHX Text
REMOVE STRAP TO SEPARATE
AutoCAD SHX Text
DEVICE
AutoCAD SHX Text
POWERED
AutoCAD SHX Text
POWERED
AutoCAD SHX Text
DEVICE
AutoCAD SHX Text
DEVICE
AutoCAD SHX Text
POWERED
AutoCAD SHX Text
PROVIDED BY AV CONTRACTOR
AutoCAD SHX Text
AUDIO-VISUAL EQUIPMENT RACK
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
AVJB
AutoCAD SHX Text
FB1
AutoCAD SHX Text
EQUIP RACK
AutoCAD SHX Text
FLOOR BOX
AutoCAD SHX Text
AUDIOVISUAL MEDIA JUNCTION BOX
AutoCAD SHX Text
FUNCTION (PANEL NAME)
AutoCAD SHX Text
ELECTRIC SCREEN CONTROL
AutoCAD SHX Text
BOX SIZE
AutoCAD SHX Text
SIZE PER NEC (APPROX 8X8X4)
AutoCAD SHX Text
2-GANG DEEP BOX
AutoCAD SHX Text
MOUNTING LOCATION
AutoCAD SHX Text
BEHIND EQUIP. RACK
AutoCAD SHX Text
FLUSH IN FLOOR AS DIRECTED ON PLANS
AutoCAD SHX Text
AT SCREEN AND AT 48" AFF FOR SWITCH
AutoCAD SHX Text
FSR FL-500P +FL-FRK-500P
AutoCAD SHX Text
BACKBOX SCHEDULE
AutoCAD SHX Text
GENERAL NOTES: 1. MOUNTING LOCATIONS ARE NOTED TO THE BOTTOM OF THE BACK BOX OR ARE NOTED ON DRAWINGS. ALL BOXES ARE RECESSED FOR FLUSH MOUNTING (TO FINISHED WALL/CEILING +0"/-1/8") UNLESS OTHERWISE NOTED. 2. COORDINATE ALL EQUIPMENT AND BACK BOX LOCATIONS WITH ELECTRICAL AND ARCHITECTURAL 3. POWER NEXT TO FLOOR BOXES SHOULD BE LOCATED IN THE FLOOR BOX
AutoCAD SHX Text
SPEAKER CLUSTER
AutoCAD SHX Text
4-GANG DEEP BOX
AutoCAD SHX Text
WP1
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
MOUNT 18" AFF AT LOCATION SHOWN
AutoCAD SHX Text
S1
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
MOUNT AT 18' AFF
AutoCAD SHX Text
WP2
AutoCAD SHX Text
FSR WB-RXG 4-GANG WITH COVER
AutoCAD SHX Text
MOUNT 18" AFF AT LOCATION SHOWN
AutoCAD SHX Text
SC
AutoCAD SHX Text
FSR FL 600P
AutoCAD SHX Text
CEILING SPEAKER
AutoCAD SHX Text
FLUSH IN CEILING
AutoCAD SHX Text
1-GANG
AutoCAD SHX Text
S
AutoCAD SHX Text
CP1
AutoCAD SHX Text
CEILING PROJECTOR PANEL
AutoCAD SHX Text
FLUSH IN ACT CEILING
AutoCAD SHX Text
FSR CB-22
AutoCAD SHX Text
MIX
AutoCAD SHX Text
AUDIO MIX LOCATION
AutoCAD SHX Text
MOUNT 18" AFF
AutoCAD SHX Text
FSR FL 700 WITH COVER
AutoCAD SHX Text
SPEAKER TYPE 2
AutoCAD SHX Text
2-GANG DEEP BOX
AutoCAD SHX Text
S2
AutoCAD SHX Text
MOUNT AT 96" AFF
AutoCAD SHX Text
RC
AutoCAD SHX Text
REMOTE CONTROL
AutoCAD SHX Text
MOUNT 48" AFF
AutoCAD SHX Text
FSR WB 3G WITH COVER
AutoCAD SHX Text
ANT
AutoCAD SHX Text
REMOTE ANTENNA
AutoCAD SHX Text
MOUNT AT CEILING
AutoCAD SHX Text
1-GANG
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
QTY
AutoCAD SHX Text
WIRE LEGEND
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
PART NUMBER
AutoCAD SHX Text
CS
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (SERIAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
CR
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (IR)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
CG
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (GENERAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9455
AutoCAD SHX Text
D
AutoCAD SHX Text
X
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1700A
AutoCAD SHX Text
P
AutoCAD SHX Text
X
AutoCAD SHX Text
LOW VOLTAGE POWER
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
8461
AutoCAD SHX Text
R
AutoCAD SHX Text
X
AutoCAD SHX Text
RGBHV 5 WIRE
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
7789A
AutoCAD SHX Text
SL
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (8 OHM) LONG
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
C-210
AutoCAD SHX Text
SH
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (8 OHM) SHORT
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
227
AutoCAD SHX Text
T
AutoCAD SHX Text
X
AutoCAD SHX Text
TELEPHONE/DATA
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1700A
AutoCAD SHX Text
CONDUCTORS
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
9 COND 20 GA
AutoCAD SHX Text
4 PR CAT 5
AutoCAD SHX Text
18/2
AutoCAD SHX Text
5 WIRE HI RES
AutoCAD SHX Text
10/2
AutoCAD SHX Text
12/2
AutoCAD SHX Text
4 PR CAT 5
AutoCAD SHX Text
V
AutoCAD SHX Text
X
AutoCAD SHX Text
COMPOSITE VIDEO
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1694A
AutoCAD SHX Text
Y
AutoCAD SHX Text
X
AutoCAD SHX Text
S-VIDEO (Y/C)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
QTY (2) 1505A
AutoCAD SHX Text
RG-6/U
AutoCAD SHX Text
(2) RG-59/U
AutoCAD SHX Text
AD
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (DIGITAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1800B
AutoCAD SHX Text
AL
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (LINE)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
AM
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (MICROPHONE)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
AP
AutoCAD SHX Text
X
AutoCAD SHX Text
MULTIPAIR AUDIO
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1817R
AutoCAD SHX Text
8 PR W/SHLD
AutoCAD SHX Text
IM
AutoCAD SHX Text
X
AutoCAD SHX Text
PRODUCTION INTERCOM
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
D-510
AutoCAD SHX Text
2 PR W/SHLD
AutoCAD SHX Text
SZ
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (70 VOLT)
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
225
AutoCAD SHX Text
16/2
AutoCAD SHX Text
REFER TO A/V SPECIFICATION FOR WIRE TYPES. REFER TO THE SINGLE LINE DRAWINGS FOR QUANTITIES.
AutoCAD SHX Text
COORDINATE ALL FINISHES WITH ARCHITECT. SUBMIT SAMPLE OF FINISHED PANEL TO ARCHITECT FOR REVIEW AND APPROVAL.
AutoCAD SHX Text
THE ELECTRICAL CONTRACTOR SHALL INCREASE THE SIZE OF BOX KNOCKOUTS AS REQUIRED AND PROVIDE APPROPRIATE FITTINGS, CONNECTORS, AND MOUNTING ACCESSORIES FOR A COMPLETE INSTALLATION IN COMPLIANCE WITH DIVISION 26.
AutoCAD SHX Text
TERMINATE ALL CONDUITS IN BACK BOXES, COLLECTOR BOXES, OR WIREWAYS AS SHOWN ON DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE PLASTIC OR RUBBER BUSHINGS AS EDGE PROTECTION WHEN CONDUITS TERMINATE AT WIREWAYS AS SHOWN. EXPOSED CONDUIT EDGES ARE UNACCEPTABLE.
AutoCAD SHX Text
THE CATEGORY AV DRAWINGS INDICATE INFRASTRUCTURE ONLY INCLUDING CONDUIT, PULL-BOXES, BACK BOXES COLLECTOR BOXES, AND/OR TERMINAL CABINETS. AV EQUIPMENT AND SIGNAL CABLE IS IN A SEPARATE AV CONTRACT.
AutoCAD SHX Text
ALL BOXES SHALL HAVE A BLANK COVER PLATE WITH THE STENCILED AV BACK BOX LABEL PAINTED ON THE INSIDE OF THE COVER PLATE FOR IDENTIFICATION.
AutoCAD SHX Text
BASED ON THE DRAWING LOCATIONS PER A, CONTRACTOR SHALL VERIFY LOCATION OF ALL BACK BOXES WITH OWNER'S REPRESENTATIVE IN THE FIELD.
AutoCAD SHX Text
REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING LOCATIONS OF ALL BACK BOXES.
AutoCAD SHX Text
WHERE CONDUIT IS TO BE SURFACE RUN, THE CONTRACTOR SHALL FINISH THE CONDUIT TO MATCH THE WALL FINISH.
AutoCAD SHX Text
LEAVE NO CONDUIT ENTERING RACKS FROM TOP AND/OR SIDES EXPOSED TO FRONT VIEW OF RACKS. PLACE TRIM OR PANELS TO HIDE CONDUIT RUNS FOR A NEAT APPEARANCE.
AutoCAD SHX Text
ELECTRICAL CONTRACTOR SHALL MAKE AVAILABLE A FIELD REPRESENTATIVE FOR THE INSTALLER OF THE A/V EQUIPMENT DURING THE A/V INSTALLATION.
AutoCAD SHX Text
ELECTRICAL CONTRACTOR SHALL DEMONSTRATE CONTINUITY OF ALL CONDUITS BY PASSING A MOUSE OR PLUG OF APPROPRIATE SIZE THROUGH EACH CONDUIT RUN.
AutoCAD SHX Text
RACKS TO BE PROVIDED BY ELECTRICAL CONTRACTOR PER DIVISION 16 IF INDICATED ON DRAWINGS. TAKE CARE TO ISOLATE ALL CONDUITS FROM THE TECHNICAL GROUND SYSTEM. BE SURE ALL CONDUITS ENTERING THE RACKS ARE INSULATED FROM THE RACKS.
AutoCAD SHX Text
PULL BOXES ARE NOT SHOWN ON THE RISERS, BUT MUST BE INSTALLED AFTER EACH 270 DEGREES OF BEND. EVERY 50 FEET OF STRAIGHT CONDUIT LENGTH SHALL BE CONSIDERED EQUIVALENT TO 90 DEGREES OF CONDUIT BEND.
AutoCAD SHX Text
IN EACH CONDUIT RUN BETWEEN SUCCESSIVE BACK BOXES AND PULL BOXES, INSTALL A LENGTH OF YELLOW PULL LINE. PULL LINE SHALL HAVE SEQUENTIAL NUMBERING AT EACH ONE FOOT MARK.
AutoCAD SHX Text
ALL CONDUIT, WIREWAYS, PULL BOXES, BACK BOXES, COLLECTOR BOXES, AND ANCILLARY FITTINGS, CONNECTORS, AND MOUNTING ACCESSORIES ASSOCIATED WITH THE AV INFRASTRUCTURE TO BE INSTALLED PER DIVISION 26.
AutoCAD SHX Text
AC POWER FOR THE A/V SYSTEMS TO BE PROVIDED BY ELECTRICAL CONTRACTOR PER DIVISION 26 IN ACCORDANCE WITH PROJECT DRAWINGS AND SPECIFICATIONS.
AutoCAD SHX Text
GENERAL INSTALLATION NOTES
AutoCAD SHX Text
ALL NEMA STYLE BACKBOXES ARE TYPE I, INDOOR, SCREW COVER ENCLOSURES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
AutoCAD SHX Text
AV CONDUIT SYSTEM:
AutoCAD SHX Text
BACK BOX LOCATIONS AND MOUNTING:
AutoCAD SHX Text
USE ALL FERROUS METAL CONDUIT. NO PVC UNLESS NOTED.
AutoCAD SHX Text
C.
AutoCAD SHX Text
D.
AutoCAD SHX Text
II.
AutoCAD SHX Text
A.
AutoCAD SHX Text
B.
AutoCAD SHX Text
M.
AutoCAD SHX Text
L.
AutoCAD SHX Text
K.
AutoCAD SHX Text
J.
AutoCAD SHX Text
I.
AutoCAD SHX Text
H.
AutoCAD SHX Text
G.
AutoCAD SHX Text
F.
AutoCAD SHX Text
D.
AutoCAD SHX Text
E.
AutoCAD SHX Text
I.
AutoCAD SHX Text
B.
AutoCAD SHX Text
C.
AutoCAD SHX Text
A.
AutoCAD SHX Text
PRELIMINARY NOT FOR CONSTRUCTION
Page 2: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

EXIT

ENTRY

EXIT

ENTRY

DN

DN

107.1

8.8

15 1613

VESTIBULE

B100

MUSIC

C102

GYM

C100

CAFETERIA

C101

KITCHEN

C103

STOR

C104

BOYS

C105

PANTRY

C106

CUST

C107

HALLWAY

C108

?

?

FAMILY TOILET

C111

BUILDING STOR

C112

CUSTODIAL

C113

MECHANICAL

C114

PE STOR

C115

ELECTRICAL

C116

SERVICE COURT

C118

LOBBY

B101

RECEPTION

B102

PRINCIPAL

B103

HEALTH

B115

7.4 7.7

7.2

J.2

15.3

J.6

12.4

GIRLS

C109

CLASSROOM

A105

CLASSROOM

CLOSET

B120

SMALL GROUP

B105

TOILET

B106

TOILET

B107

HALLWAY

B108

HALLWAY

B109

MEDIA CENTER

B116

HALLWAY

B121

HALLWAY

B122

TOILET

B123

BOYS

B124

GIRLS

B125

MDF

B126

WORK ROOM

B117

8.9

8.3 8.6

A.7

RE

VIS

IO

NS

:P

RO

JE

CT

#:

IS

SU

E D

AT

E:

PR

IN

TE

D O

N:

20

14

P

IV

OT

A

RC

HIT

EC

TU

RE

FR

OM

F

IL

E:

C

AV

F

IR

ST

F

LO

OR

P

LA

NE

UG

EN

E S

CH

OO

L D

IS

TR

IC

T 4

J

RIV

ER

R

OA

D / E

L C

AM

IN

O D

EL R

IO

E

LE

ME

NT

AR

Y S

CH

OO

L

13

37

.0

0

02

.1

22

01

6

AV101

12

0 W

ES

T H

IL

LIA

RD

A

VE

NU

E, E

UG

EN

E, O

RE

GO

N 9

74

04

LIS

TE

N A

CO

US

TIC

S

1001

SW

5TH

AVE

SUIT

E 11

00PO

RTLA

ND, o

r 972

0450

3-24

1-52

55

BID

S

ET

A B

C

KEY PLAN

AutoCAD SHX Text
FB1
AutoCAD SHX Text
FB1
AutoCAD SHX Text
S1
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
(2) 2" 2 D 4 AM 1 SL
AutoCAD SHX Text
EQUIP RACK
AutoCAD SHX Text
MIX
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
3" 4 D 16 AM
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
ALS
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
3/4" 2 V
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
3/4" V
AutoCAD SHX Text
EQUIP RACK
AutoCAD SHX Text
AVJB
AutoCAD SHX Text
WP2
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
2" 4 D 4 AM
AutoCAD SHX Text
ANT
AutoCAD SHX Text
ALS
AutoCAD SHX Text
ANT
AutoCAD SHX Text
WP1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
2" 4 D
AutoCAD SHX Text
S1
AutoCAD SHX Text
S1
AutoCAD SHX Text
TO EQUIP RACK
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
RC
AutoCAD SHX Text
3/4" 2D
AutoCAD SHX Text
TO EQUIP RACK
AutoCAD SHX Text
RC
AutoCAD SHX Text
3/4" 2D
AutoCAD SHX Text
RC
AutoCAD SHX Text
3/4" 2D
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
REAR PROJECTION SCREEN
AutoCAD SHX Text
SC
AutoCAD SHX Text
SC
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
(2) 2" 2 D 4 AM 1 SL
AutoCAD SHX Text
3/4" 1 CG ELECTRIC PROJECTOIN SCREEN CONTROL
AutoCAD SHX Text
CP1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
CP1
AutoCAD SHX Text
TO AVJB
AutoCAD SHX Text
1" 2 SL
AutoCAD SHX Text
AT CEILING
AutoCAD SHX Text
SPEAKER PROTECTION CAGE
AutoCAD SHX Text
SPEAKER PROTECTION CAGE
AutoCAD SHX Text
AT CEILING
AutoCAD SHX Text
MOUNT MIX AND RC BOXES INSIDE AV RACK IN CABINET
AutoCAD SHX Text
PROVIDED BY AV CONTRACTOR
AutoCAD SHX Text
AUDIO-VISUAL EQUIPMENT RACK
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
AVJB
AutoCAD SHX Text
FB1
AutoCAD SHX Text
EQUIP RACK
AutoCAD SHX Text
FLOOR BOX
AutoCAD SHX Text
AUDIOVISUAL MEDIA JUNCTION BOX
AutoCAD SHX Text
FUNCTION (PANEL NAME)
AutoCAD SHX Text
ELECTRIC SCREEN CONTROL
AutoCAD SHX Text
BOX SIZE
AutoCAD SHX Text
SIZE PER NEC (APPROX 8X8X4)
AutoCAD SHX Text
2-GANG DEEP BOX
AutoCAD SHX Text
MOUNTING LOCATION
AutoCAD SHX Text
BEHIND EQUIP. RACK
AutoCAD SHX Text
FLUSH IN FLOOR AS DIRECTED ON PLANS
AutoCAD SHX Text
AT SCREEN AND AT 48" AFF FOR SWITCH
AutoCAD SHX Text
FSR FL-500P +FL-FRK-500P
AutoCAD SHX Text
BACKBOX SCHEDULE
AutoCAD SHX Text
GENERAL NOTES: 1. MOUNTING LOCATIONS ARE NOTED TO THE BOTTOM OF THE BACK BOX OR ARE NOTED ON DRAWINGS. ALL BOXES ARE RECESSED FOR FLUSH MOUNTING (TO FINISHED WALL/CEILING +0"/-1/8") UNLESS OTHERWISE NOTED. 2. COORDINATE ALL EQUIPMENT AND BACK BOX LOCATIONS WITH ELECTRICAL AND ARCHITECTURAL 3. POWER NEXT TO FLOOR BOXES SHOULD BE LOCATED IN THE FLOOR BOX
AutoCAD SHX Text
SPEAKER CLUSTER
AutoCAD SHX Text
4-GANG DEEP BOX
AutoCAD SHX Text
WP1
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
MOUNT 18" AFF AT LOCATION SHOWN
AutoCAD SHX Text
S1
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
MOUNT AT 18' AFF
AutoCAD SHX Text
WP2
AutoCAD SHX Text
FSR WB-RXG 4-GANG WITH COVER
AutoCAD SHX Text
MOUNT 18" AFF AT LOCATION SHOWN
AutoCAD SHX Text
SC
AutoCAD SHX Text
FSR FL 600P
AutoCAD SHX Text
CEILING SPEAKER
AutoCAD SHX Text
FLUSH IN CEILING
AutoCAD SHX Text
1-GANG
AutoCAD SHX Text
S
AutoCAD SHX Text
CP1
AutoCAD SHX Text
CEILING PROJECTOR PANEL
AutoCAD SHX Text
FLUSH IN ACT CEILING
AutoCAD SHX Text
FSR CB-22
AutoCAD SHX Text
MIX
AutoCAD SHX Text
AUDIO MIX LOCATION
AutoCAD SHX Text
MOUNT 18" AFF
AutoCAD SHX Text
FSR FL 700 WITH COVER
AutoCAD SHX Text
MOUNT 60" AFF
AutoCAD SHX Text
SPEAKER TYPE 2
AutoCAD SHX Text
2-GANG DEEP BOX
AutoCAD SHX Text
S2
AutoCAD SHX Text
MOUNT AT 96" AFF
AutoCAD SHX Text
RC
AutoCAD SHX Text
REMOTE CONTROL
AutoCAD SHX Text
MOUNT 48" AFF
AutoCAD SHX Text
FSR WB 3G WITH COVER
AutoCAD SHX Text
ANT
AutoCAD SHX Text
REMOTE ANTENNA
AutoCAD SHX Text
MOUNT AT CEILING
AutoCAD SHX Text
1-GANG
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
QTY
AutoCAD SHX Text
WIRE LEGEND
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
PART NUMBER
AutoCAD SHX Text
CS
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (SERIAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
CR
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (IR)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
CG
AutoCAD SHX Text
X
AutoCAD SHX Text
CONTROL (GENERAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9455
AutoCAD SHX Text
D
AutoCAD SHX Text
X
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1700A
AutoCAD SHX Text
P
AutoCAD SHX Text
X
AutoCAD SHX Text
LOW VOLTAGE POWER
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
8461
AutoCAD SHX Text
R
AutoCAD SHX Text
X
AutoCAD SHX Text
RGBHV 5 WIRE
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
7789A
AutoCAD SHX Text
SL
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (8 OHM) LONG
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
C-210
AutoCAD SHX Text
SH
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (8 OHM) SHORT
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
227
AutoCAD SHX Text
T
AutoCAD SHX Text
X
AutoCAD SHX Text
TELEPHONE/DATA
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1700A
AutoCAD SHX Text
CONDUCTORS
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
9 COND 20 GA
AutoCAD SHX Text
4 PR CAT 5
AutoCAD SHX Text
18/2
AutoCAD SHX Text
5 WIRE HI RES
AutoCAD SHX Text
10/2
AutoCAD SHX Text
12/2
AutoCAD SHX Text
4 PR CAT 5
AutoCAD SHX Text
V
AutoCAD SHX Text
X
AutoCAD SHX Text
COMPOSITE VIDEO
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1694A
AutoCAD SHX Text
Y
AutoCAD SHX Text
X
AutoCAD SHX Text
S-VIDEO (Y/C)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
QTY (2) 1505A
AutoCAD SHX Text
RG-6/U
AutoCAD SHX Text
(2) RG-59/U
AutoCAD SHX Text
AD
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (DIGITAL)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1800B
AutoCAD SHX Text
AL
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (LINE)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
AM
AutoCAD SHX Text
X
AutoCAD SHX Text
AUDIO (MICROPHONE)
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
9451
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
1 PR W/SHLD
AutoCAD SHX Text
AP
AutoCAD SHX Text
X
AutoCAD SHX Text
MULTIPAIR AUDIO
AutoCAD SHX Text
BELDEN
AutoCAD SHX Text
1817R
AutoCAD SHX Text
8 PR W/SHLD
AutoCAD SHX Text
IM
AutoCAD SHX Text
X
AutoCAD SHX Text
PRODUCTION INTERCOM
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
D-510
AutoCAD SHX Text
2 PR W/SHLD
AutoCAD SHX Text
SZ
AutoCAD SHX Text
X
AutoCAD SHX Text
SPEAKER (70 VOLT)
AutoCAD SHX Text
WEST PENN
AutoCAD SHX Text
225
AutoCAD SHX Text
16/2
AutoCAD SHX Text
LCD
AutoCAD SHX Text
2" 2 D 1 HD
AutoCAD SHX Text
WP2
AutoCAD SHX Text
WP2
AutoCAD SHX Text
2" 2 D 1 HD
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
3/4" SL
AutoCAD SHX Text
3/4" SL
AutoCAD SHX Text
PRELIMINARY NOT FOR CONSTRUCTION
Page 3: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

AUDIO AMPLIFIER

CROWN

AUDIO AMPLIFIER

CROWN

CONTROL PANEL AT MIX

CUSTOM FLOOR PLATE (FP1)

FRONT OF STAGE

ASSIST. LISTENING TRANSMITTER

CAFETERIA

AUDIO CONSOLE

AUDIO DSP MATRIX MAIN SPEAKER

JBL

DELAY SPEAKER

JBL

MAIN SPEAKER

JBL

DELAYSPEAKER

JBL

WIRELESS MICS

CUSTOM FLOOR PLATE (FP1)

FRONT OF STAGE

CUSTOM WALL PLATE (WP1)

REAR OF STAGE

AUDIO AMPLIFIER

CROWN

CAFETERIA DELAY SPEAKER

JBL

CAFETERIA DELAYSPEAKER

JBL

INPUT PANEL AT CAFETERIA

ASSIST. LISTENING TRANSMITTER

GYM

WALL PANEL

SPEAKER LEFT

JBL

SPEAKER RIGHT

JBL

MIX-AMP

PORTABLE AV RACK

GYM+ CAFETERIA AUDIO

A B

C

RE

VIS

IO

NS

:P

RO

JE

CT

#:

IS

SU

E D

AT

E:

PR

IN

TE

D O

N:

20

14

P

IV

OT

A

RC

HIT

EC

TU

RE

FR

OM

F

IL

E:

C

KEY PLAN

AV

G

YM

+

C

AF

ET

ER

IA

+

M

ED

IA

AU

DIO

EU

GE

NE

S

CH

OO

L D

IS

TR

IC

T 4

J

RIV

ER

R

OA

D / E

L C

AM

IN

O D

EL R

IO

E

LE

ME

NT

AR

Y S

CH

OO

L

13

37

.0

0

02

.1

2.2

01

5

AV300

12

0 W

ES

T H

IL

LIA

RD

A

VE

NU

E, E

UG

EN

E, O

RE

GO

N 9

74

04

LIS

TE

N A

CO

US

TIC

S

1001

SW

5TH

AVE

SUIT

E 11

00PO

RTLA

ND, o

r 972

0450

3-24

1-52

55

BID

S

ET

MEDIA AUDIO

AutoCAD SHX Text
CH1 IN
AutoCAD SHX Text
CH2 IN
AutoCAD SHX Text
CH1 OUT
AutoCAD SHX Text
CH2 OUT
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
CH1 IN
AutoCAD SHX Text
CH2 IN
AutoCAD SHX Text
CH1 OUT
AutoCAD SHX Text
CH2 OUT
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
CG
AutoCAD SHX Text
CTRL
AutoCAD SHX Text
CTRL
AutoCAD SHX Text
CG
AutoCAD SHX Text
AM
AutoCAD SHX Text
AL
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
24V
AutoCAD SHX Text
DC
AutoCAD SHX Text
IN
AutoCAD SHX Text
AL
AutoCAD SHX Text
AM
AutoCAD SHX Text
Typ. of 8
AutoCAD SHX Text
Input 1
AutoCAD SHX Text
Input 2
AutoCAD SHX Text
Input 3
AutoCAD SHX Text
Input 4
AutoCAD SHX Text
Input 5
AutoCAD SHX Text
Input 6
AutoCAD SHX Text
Input 7
AutoCAD SHX Text
Input 8
AutoCAD SHX Text
Input 9
AutoCAD SHX Text
Input 10
AutoCAD SHX Text
Input 11
AutoCAD SHX Text
Input 12
AutoCAD SHX Text
Input 13
AutoCAD SHX Text
Input 14
AutoCAD SHX Text
Input 15
AutoCAD SHX Text
Input 16
AutoCAD SHX Text
Input 17
AutoCAD SHX Text
Input 18
AutoCAD SHX Text
Input 19
AutoCAD SHX Text
Input 20
AutoCAD SHX Text
Input 21
AutoCAD SHX Text
Input 22
AutoCAD SHX Text
Input 23
AutoCAD SHX Text
Input 24
AutoCAD SHX Text
Input 25
AutoCAD SHX Text
Input 26
AutoCAD SHX Text
Input 27
AutoCAD SHX Text
Input 28
AutoCAD SHX Text
Input 29
AutoCAD SHX Text
Input 30
AutoCAD SHX Text
Input 31
AutoCAD SHX Text
Input 32
AutoCAD SHX Text
Input 33
AutoCAD SHX Text
Input 34
AutoCAD SHX Text
Input 35
AutoCAD SHX Text
Input 36
AutoCAD SHX Text
Input 37
AutoCAD SHX Text
Input 38
AutoCAD SHX Text
Input 39
AutoCAD SHX Text
Input 40
AutoCAD SHX Text
Input 41
AutoCAD SHX Text
Input 42
AutoCAD SHX Text
Input 43
AutoCAD SHX Text
Input 44
AutoCAD SHX Text
Input 45
AutoCAD SHX Text
Input 46
AutoCAD SHX Text
Input 47
AutoCAD SHX Text
Input 48
AutoCAD SHX Text
Stereo Line Audio In
AutoCAD SHX Text
MAIN OUT MONO
AutoCAD SHX Text
AUX 1
AutoCAD SHX Text
AUX 2
AutoCAD SHX Text
AUX 3
AutoCAD SHX Text
AUX 4
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
Input 1
AutoCAD SHX Text
Input 2
AutoCAD SHX Text
Input 3
AutoCAD SHX Text
Input 4
AutoCAD SHX Text
Input 5
AutoCAD SHX Text
Input 6
AutoCAD SHX Text
Input 7
AutoCAD SHX Text
Input 8
AutoCAD SHX Text
Control In 1,2,C
AutoCAD SHX Text
DSP NET
AutoCAD SHX Text
Output 1
AutoCAD SHX Text
Output 2
AutoCAD SHX Text
Output 3
AutoCAD SHX Text
Output 4
AutoCAD SHX Text
Output 5
AutoCAD SHX Text
Output 6
AutoCAD SHX Text
Output 7
AutoCAD SHX Text
Output 8
AutoCAD SHX Text
Logic Out 1,2,C
AutoCAD SHX Text
Network Out
AutoCAD SHX Text
RS-232
AutoCAD SHX Text
AL
AutoCAD SHX Text
MULTIPIN CONNECTOR
AutoCAD SHX Text
AM
AutoCAD SHX Text
Typ. of 2
AutoCAD SHX Text
AUTO MIC
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AM
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
MULTIPIN
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
FROM DSP OUT
AutoCAD SHX Text
D
AutoCAD SHX Text
CG
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
TO MIX
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
Typ. of 8
AutoCAD SHX Text
AM
AutoCAD SHX Text
Typ. of 8
AutoCAD SHX Text
SL
AutoCAD SHX Text
CH1 IN
AutoCAD SHX Text
CH2 IN
AutoCAD SHX Text
CH1 OUT
AutoCAD SHX Text
CH2 OUT
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
SL
AutoCAD SHX Text
TO REMOTE ANTENNA
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
AM
AutoCAD SHX Text
GYM
AutoCAD SHX Text
CAFETERIA
AutoCAD SHX Text
IN
AutoCAD SHX Text
TO REMOTE ANTENNA
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AMX CONTROL BY OTHERS
AutoCAD SHX Text
AL
AutoCAD SHX Text
SH
AutoCAD SHX Text
SH
AutoCAD SHX Text
CAT-5 IN
AutoCAD SHX Text
CAT-5 OUT
AutoCAD SHX Text
MASTER AUD OUT L
AutoCAD SHX Text
MASTER AUD OUT R
AutoCAD SHX Text
RS 232
AutoCAD SHX Text
SL
AutoCAD SHX Text
SL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
AL
AutoCAD SHX Text
PRELIMINARY NOT FOR CONSTRUCTION
Page 4: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

IDF.2

2ND FLOOR

(2) 2"C, (2) 4"C

TO MEET ME VAULT

(2) 1-1/4"C TO FUTURE

CHARGING STATIONS CAP

AND LOCATE WITH PAINTED

REBAR, INSTALL 200LB

PULL ROPE.

IDF.3

IN MEZZANINE

MDF.1

JUNCTION BOX 24X36X18"

SYNERTECH #S2436B18FA BASE

SYNERTECH #S2436HCBOA COVER

(1) 1-1/4"C

TO MONUMENT

(2) 4"C AND (2) 2"C

(2) 1-1/4"C

TO 12X12X4

J-BOX IN

POLE BASE

(1) 1-1/4"C

TO 8X8X4

J-BOX IN

POLE BASE

(1) 1-1/4"C. TO 12X12X4 J-BOX IN

POLE BASE FOR SECURITY CAMERA

EWEB POLE 512(2) 4" C. AND (2) 2" C

BORE ACROSS STREET

25-TA MEET ME

UTILITY VAULT

REFER TO ARCHITECT

DRAWINGS FOR

EXACT PLACEMENT

1.25" C TO

COVERED PLAY

1.25" RMT ELBOW TO COLUMN

BASE EXTEND RMT 6" ABOVE

GRADE AND CAP.

0 5 10 25 50 75 100

SCALE IN FEET

1. PROVIDE (1) CARLON E1212C24 POLE BASE J-BOX WITH

ELECTRICAL DIVIDER.

2. PROVIDE (1) CARLON E88C24 POLE BASE J-BOX.

KEYED NOTES: -

1. ALL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40

UNLESS OTHERWISE NOTED.

2. PROVIDE #10 COPPER FOR FUTURE LOCATE. COIL 12" AT EACH

PULL VAULT.

GENERAL NOTES: -

X

2

2

2

1

(2) 4"C AND (2) 2"C

1

(1) 2"C. TO 12X12X4 NEMA 4R J-BOX

FOR ACCESS CONROLLED GATE

JUNCTION BOX 24X36X18"

SYNERTECH #S2436B18FA BASE

SYNERTECH #S2436HCBOA COVER

EXISTING EWEB VAULT, STUB CONDUITS INTO

VAULT.

(2) 4"C AND (2) 2"C

COVER with

ADJUSTABLE FRAME

No. 25P ASSEMBLY

BASE

No. 25-BT

oldcastleprecast.com/wilsonville

Issue Date:

File Name:

PO Box 323, Wilsonville, Oregon 97070-0323

Tel: (503) 682-2844 Fax: (503) 682-2657

25-TA

2011

020UTT25TA1

25-TA

2 x 5 x 2

COMMUNICATIONS

25-TA

PLAN VIEW

SECTION AA END VIEW

A A

Issue Date:

File Name:

PO Box 323, Wilsonville, Oregon 97070-0323

Tel: (503) 682-2844 Fax: (503) 682-2657

oldcastleprecast.com/wilsonville

25-TA

2011

020UTT25TA2

25-TA

2 x 5 x 2

COMMUNICATIONS

25-TA

SIT

E P

LA

N

T1.00

1

T100

SITE PLAN1/32"=1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

2

T100

MEET ME VAULT 25-TAAS NOTED

2

T100

JUNCTION BOX / PULL BOXAS NOTED

Page 5: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

DN

DN

W D

CLASSROOM

A100

CLASSROOM

A101

CLASSROOM

A102

CLASSROOM

A103

CLASSROOM

A104

CLASSROOM

A105

CLASSROOM

A114

CLASSROOM

A113

CLASSROOM

A110

CLASSROOM

A109

CLASSROOM

A106

TOILET

A122

CUST

A119

BOYS

A121

GIRLS

A120

WORK

A118

HALLWAY

A117

STAIR

A116

COMMONS

A112

HALLWAY

A111

COMMONS

A108

VESTIBULE

B100

MUSIC

C102

GYM

C100

CAFETERIA

C101

KITCHEN

C103

STOR

C104

BOYS

C105

PANTRY

C106

CUST

C107

HALLWAY

C108

?

?

FAMILY TOILET

C111

BUILDING STOR

C112

CUSTODIAL

C113

MECHANICAL

C114

PE STOR

C115

ELECTRICAL

C116

SERVICE COURT

C118

LOBBY

B101

COMMUNITY

B119

CLOSET

B120

RECEPTION

B102

PRINCIPAL

B103

CONFERENCE

B104

SMALL GROUP

B105

TOILET

B106

TOILET

B107

HALLWAY

B108

HALLWAY

B109

LAC

B110

TOILET

B111

RECORDS

B112

QUIET ROOM

B113

TOILET

B114

HEALTH

B115

MEDIA CENTER

B116

HALLWAY

B118

HALLWAY

B121

HALLWAY

B122

TOILET

B123

BOYS

B124

GIRLS

B125

MDF

B126

WORK ROOM

B117

GIRLS

C109

(3) 3" C.

UNDER SLAB

(1) 1.25"C

UNDER SLAB.

2" C TO IDF.2

SEE T100

1

T501

STUB (5) 4"C TO IDF.3 IN

MEZZANINE ABOVE

(1) 2" C. UNDERSLAB

STUB UP WALL ABOVE CEILING

OF MUSIC C102

1.25" C TO IDF.2

STUB UP INTO

POLE BASE J-BOX

SEE T100

(2) 1.25" C.

FOR AV

12"X4"

CABLE

TRAY

FIELD

VERIFY

HEIGHT

OV

ER

AL

L F

IR

ST

F

LO

OR

T1.01

1

T101

OVERALL FIRST FLOOR PLAN5/64" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

ge

ne

S

ch

oo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

ge

ne

S

ch

oo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 6: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

CLASSROOM

A200

CLASSROOM

A203

CLASSROOM

A204

CLASSROOM

A205

CLASSROOM

A206

COMMONS

A208

CLASSROOM

A209

CLASSROOM

A210

HALLWAY

A211

COMMONS

A212

CLASSROOM

A213

ELL

A214

HALLWAY

A217

IDF

A219

GIRLS

A220

TOILET

A222

SPEECH

A223

MECHANICAL PLATFORM

C300

STAFF

B200

ELEC

B202

TECH

B203

STAFF TOILET

B211

HALLWAY

B215

TOILET

B214

BOYS

B213

GIRLS

B212

ELEVATOR

B216

HALLWAY

B201

OFFICE

B207

CUST

B208

WORKROOM

B209

HALLWAY

B210

HALLWAY

B205

OFFICE

B204

BOYS

A221

OBSERVATORY

B206

CLASSROOM

A202

CLASSROOM

A201

IDF.3, 2-POST EQUIPMENT RACK

LOCATION AND

CLEARSPACE REQUIREMENT,

COORDINATE WITH MECHANICAL

LAYOUT.

ATTACH TO WALL WITH 12" LADDER

TRAY.

2

T501

3

T501

OV

ER

ALL

S

EC

ON

D F

LO

OR

PL

AN

13

37

T1.02

1

T102

OVERALL SECOND FLOOR PLAN3/32" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 7: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

CLASSROOM

A100

CLASSROOM

A101

CLASSROOM

A102

CLASSROOM

A103

CLASSROOM

A104

CLASSROOM

A105

CLASSROOM

A114

CLASSROOM

A113

CLASSROOM

A110

CLASSROOM

A109

CLASSROOM

A106

TOILET

A122

CUST

A119

BOYS

A121

GIRLS

A120

WORK

A118

HALLWAY

A117

STAIR

A116

COMMONS

A112

HALLWAY

A111

COMMONS

A108

HALLWAY

TOILET

B123

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

AV

ENCL

W

AV

ENCL

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

C

C

M

D

D

D

D

DD

D

C

D

D

14

14

2" C TO IDF.2

SEE T100

M

15

47" OFCI LCD

DISPLAY AT +84"

47" OFCI LCD

DISPLAY AT +84"

1.25" C TO IDF.2

STUB UP INTO

POLE BASE J-BOX

SEE T100

C

IR

IR

IR

IR

IR

IR

IRIR

IR

IR

IR

6 6

66

+144"

TYPICAL

+144"

TYPICAL

+144"

TYPICAL

+144"

TYPICAL

+144"

TYPICAL

6

15

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

P

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

I

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE. REFER TO ARCHITECT REFLECTED

CEILING PLAN FOR EXACT PLACEMENT.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER BEHIND OFCI

DISPLAY.

1. INSTALL OWNER FURNISHED NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

MAINTAIN 12" CLEAR BETWEEN ARMING AND DOOR CONTROL

PINPADS.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

PINPAD CONTROL OF LOCK AT MAIN OFFICE VESTIBULE ENTRY.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER. MOUNT AT 108" AFF

UNLESS OTHERWISE NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION. PROVIDE CAMDEN CM25/3 AND

LOCAL REX FOR DOORS (4) TOTAL AT VESTIBULE B100.

11. PROVIDE (2) 1"C FROM PRESENTER LOCATION TO CEILING OF

MUSIC ROOM FOR PROJECTOR AV CABLING.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 16/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON T5.01.

15. HOMERUN AMX AX-LINK CABLE TO NEAREST NX-12OO

CONTROLLER.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS CABLING AND ROUGH IN ONLY.

CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDE 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL..

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST SECURITY PANEL OR ZONE

EXPANDER.

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (2) 1" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

7. ORANGE SECURITY CABLE IS OWNER FURNISHED AND

CONTRACTOR INSTALLED. CONTRACTOR IS TO PROVIDE

PROJECTED AMOUNT OF CABLE NEEDED BY CONDUCTOR SIZE

AND COUNT A MINIMUM OF (4) WEEKS BEFORE INSTALLATION

IS SCHEDULED TO COMMENCE.

8. PROVIDE APPROPRIATELY SIZED WIREMESH CAGES FOR

DEVICES MOUNTED IN THE GYM AND COMMONS.

GENERAL NOTES: -

X

FIR

ST

F

LO

OR

P

LA

N

SE

CT

OR

- A

T1.11

1

T111

PARTIAL FIRST FLOORPLAN - SECTOR A1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 8: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

VESTIBULE

B100

LOBBY

B101

COMMUNITY

B119

CLOSET

B120

RECEPTION

B102

PRINCIPAL

B103

CONFERENCE

B104

SMALL GROUP

B105

TOILET

B106

TOILET

B107

HALLWAY

B108

HALLWAY

B109

LAC

B110

TOILET

B111

RECORDS

B112

QUIET ROOM

B113

TOILET

B114

HEALTH

B115

MEDIA CENTER

B116

HALLWAY

B118

HALLWAY

B121

HALLWAY

B122

TOILET

B123

BOYS

B124

GIRLS

B125

MDF

B126

WORK ROOM

B117

W

C

W

W

W

W

W

W W

C

C

C

C

P

P

3

2

P

2

M

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D

M

1

7

5

8

4

M

M

1010

+60"

+144"

TYPICAL

AV

ENCL

AV

ENCL

C

IR

IR

6

6

C

C C

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

P

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

I

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE. REFER TO ARCHITECT REFLECTED

CEILING PLAN FOR EXACT PLACEMENT.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER BEHIND OFCI

DISPLAY.

1. INSTALL OWNER FURNISHED NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

MAINTAIN 12" CLEAR BETWEEN ARMING AND DOOR CONTROL

PINPADS.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

PINPAD CONTROL OF LOCK AT MAIN OFFICE VESTIBULE ENTRY.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER. MOUNT AT 108" AFF

UNLESS OTHERWISE NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION. PROVIDE CAMDEN CM25/3 AND

LOCAL REX FOR DOORS (4) TOTAL AT VESTIBULE B100.

11. PROVIDE (2) 1"C FROM PRESENTER LOCATION TO CEILING OF

MUSIC ROOM FOR PROJECTOR AV CABLING.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 16/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON T5.01.

15. HOMERUN AMX AX-LINK CABLE TO NEAREST NX-12OO

CONTROLLER.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS CABLING AND ROUGH IN ONLY.

CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDE 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL..

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST SECURITY PANEL OR ZONE

EXPANDER.

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (2) 1" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

7. ORANGE SECURITY CABLE IS OWNER FURNISHED AND

CONTRACTOR INSTALLED. CONTRACTOR IS TO PROVIDE

PROJECTED AMOUNT OF CABLE NEEDED BY CONDUCTOR SIZE

AND COUNT A MINIMUM OF (4) WEEKS BEFORE INSTALLATION

IS SCHEDULED TO COMMENCE.

8. PROVIDE APPROPRIATELY SIZED WIREMESH CAGES FOR

DEVICES MOUNTED IN THE GYM AND COMMONS.

GENERAL NOTES: -

X

FIR

ST

F

LO

OR

P

LA

N

SE

CT

OR

- B

13

37

AP

RIL

2

2, 2

01

5

T1.12

1

T112

PARTIAL FIRST FLOORPLAN - SECTOR B1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 9: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

DN

DN

W D

VESTIBULE

B100

MUSIC

C102

GYM

C100

CAFETERIA

C101

KITCHEN

C103

STOR

C104

BOYS

C105

PANTRY

C106

CUST

C107

HALLWAY

C108

?

?

FAMILY TOILET

C111

BUILDING STOR

C112

CUSTODIAL

C113

MECHANICAL

C114

PE STOR

C115

ELECTRICAL

C116

SERVICE COURT

C118

GIRLS

C109

C

C

C

W

W

W W

W

W

W

W

AV

ENCL

K

C

C

C

C

P

P

2

M

M

M

M

CC

S

C

C

P

2

13

13

13

W

W

D

D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D

D

DD

D

D

D

D

DD

D

D

D

D

D

D

1

M

1

1

1

5

3

1010

+60"

+144"

TYPICAL

11

(1) 1.25"C

UNDER SLAB TO

C112.

D

C

C

J

J

DOOR BELL ANNUNCIATOR

FROM GATE NEAR SERVICE

YARD

DOOR BELL TO

KITCHEN ANNUNCIATOR

MOTORIZED CARD ACCESS

GATE REFER TO ARCHITECT

DRAWINGS

AV

ENCL

AV

ENCL

C

FIELD LOCATE FOR

DDC CONTROLS

FIELD LOCATE FOR

IRRIGATION CONTROLS

IR

6

6

6

6

+144"

TYPICAL

+144"

TYPICAL

12"X4"

CABLE

TRAY

FIELD

VERIFY

HEIGHT

+120"

15

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

P

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

I

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE. REFER TO ARCHITECT REFLECTED

CEILING PLAN FOR EXACT PLACEMENT.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER BEHIND OFCI

DISPLAY.

1. INSTALL OWNER FURNISHED NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

MAINTAIN 12" CLEAR BETWEEN ARMING AND DOOR CONTROL

PINPADS.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

PINPAD CONTROL OF LOCK AT MAIN OFFICE VESTIBULE ENTRY.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER. MOUNT AT 108" AFF

UNLESS OTHERWISE NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION. PROVIDE CAMDEN CM25/3 AND

LOCAL REX FOR DOORS (4) TOTAL AT VESTIBULE B100.

11. PROVIDE (2) 1"C FROM PRESENTER LOCATION TO CEILING OF

MUSIC ROOM FOR PROJECTOR AV CABLING.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 16/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON T5.01.

15. HOMERUN AMX AX-LINK CABLE TO NEAREST NX-12OO

CONTROLLER.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS CABLING AND ROUGH IN ONLY.

CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDE 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL..

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST SECURITY PANEL OR ZONE

EXPANDER.

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (2) 1" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

7. ORANGE SECURITY CABLE IS OWNER FURNISHED AND

CONTRACTOR INSTALLED. CONTRACTOR IS TO PROVIDE

PROJECTED AMOUNT OF CABLE NEEDED BY CONDUCTOR SIZE

AND COUNT A MINIMUM OF (4) WEEKS BEFORE INSTALLATION

IS SCHEDULED TO COMMENCE.

8. PROVIDE APPROPRIATELY SIZED WIREMESH CAGES FOR

DEVICES MOUNTED IN THE GYM AND COMMONS.

GENERAL NOTES: -

X

FIR

ST

F

LO

OR

P

LA

N

SE

CT

OR

- C

T1.13

1

T113

PARTIAL FIRST FLOORPLAN - SECTOR C1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 10: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

CLASSROOM

A200

CLASSROOM

A203

CLASSROOM

A204

CLASSROOM

A205

CLASSROOM

A206

COMMONS

A208

CLASSROOM

A209

CLASSROOM

A210

HALLWAY

A211

COMMONS

A212

CLASSROOM

A213

ELL

A214

HALLWAY

A217

IDF

A219

GIRLS

A220

TOILET

A222

SPEECH

A223

HALLWAY

TOILET

B214

HALLWAY

B210

BOYS

A221

CLASSROOM

A202

CLASSROOM

A201

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

AV

ENCL

W

AV

ENCL

W

W

AV

ENCL

W

AV

ENCL

AV

ENCL

W

M

M

M

DD

DD

2

T501

47" OFCI LCD

DISPLAY AT +84"

47" OFCI LCD

DISPLAY AT +84"

D

D

11

11

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

IR

14

11

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

K

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE OR NEAREST IDF/MDF ROOM.

REFER TO ARCHITECT REFLECTED CEILING PLAN FOR EXACT

PLACEMENT.

I

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER, ATTACH TO REAR

OF OFCI LCD.

1. PROVIDE PROTECTIVE NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER AT 108" AFF, UNLESS

NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION.

11. HOMERUN CATEGORY 5E GREY CABLE FROM 8-BUTTON

KEYPAD TO NEAREST NX-12OO CONTROLLER.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 18/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON DETAIL 1 OF

SHEET T5.01.

15. NOT USED.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS AS SHOWN CABLING AND ROUGH IN

ONLY. CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDED 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL.

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST ACCESS PANEL

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (1) 2" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

GENERAL NOTES: -

X

SE

CO

ND

F

LO

OR

P

LA

N

SE

CT

OR

- A

T1.14

1

T114

PARTIAL SECOND FLOORPLAN - SECTOR A1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene S

choo

l D

istrict

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 11: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

STAFF

B200

ELEC

B202

TECH

B203

STAFF TOILET

B211

HALLWAY

B215

TOILET

B214

BOYS

B213

GIRLS

B212

ELEVATOR

B216

HALLWAY

B201

OFFICE

B207

CUST

B208

WORKROOM

B209

HALLWAY

B210

HALLWAY

B205

OFFICE

B204

OBSERVATORY

B206

W

AV

ENCL

P

M

C

P

W

D

D

IR

IR

W

W

I

W

14

6

+120" +120" +120"

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

K

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE OR NEAREST IDF/MDF ROOM.

REFER TO ARCHITECT REFLECTED CEILING PLAN FOR EXACT

PLACEMENT.

I

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER, ATTACH TO REAR

OF OFCI LCD.

1. PROVIDE PROTECTIVE NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER AT 108" AFF, UNLESS

NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION.

11. HOMERUN CATEGORY 5E GREY CABLE FROM 8-BUTTON

KEYPAD TO NEAREST NX-12OO CONTROLLER.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 18/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON DETAIL 1 OF

SHEET T5.01.

15. NOT USED.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS AS SHOWN CABLING AND ROUGH IN

ONLY. CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDED 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL.

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST ACCESS PANEL

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (1) 2" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

GENERAL NOTES: -

X

SE

CO

ND

F

LO

OR

P

LA

N -

SE

CT

OR

B

T1.15

1

T115

PARTIAL SECOND FLOORPLAN - SECTOR B1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene S

choo

l D

istrict

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 12: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

MECHANICAL

PLATFORM

C300

IDF.3, 2-POST EQUIPMENT RACK

LOCATION AND

CLEARSPACE REQUIREMENT,

COORDINATE WITH MECHANICAL

LAYOUT.

ATTACH TO WALL WITH 12" LADDER

TRAY.

P

3

T501

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

K

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE OR NEAREST IDF/MDF ROOM.

REFER TO ARCHITECT REFLECTED CEILING PLAN FOR EXACT

PLACEMENT.

I

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER, ATTACH TO REAR

OF OFCI LCD.

1. PROVIDE PROTECTIVE NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER AT 108" AFF, UNLESS

NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION.

11. HOMERUN CATEGORY 5E GREY CABLE FROM 8-BUTTON

KEYPAD TO NEAREST NX-12OO CONTROLLER.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 18/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON DETAIL 1 OF

SHEET T5.01.

15. NOT USED.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS AS SHOWN CABLING AND ROUGH IN

ONLY. CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDED 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL.

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST ACCESS PANEL

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (1) 2" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

GENERAL NOTES: -

X

SE

CO

ND

F

LO

OR

P

LA

N -

SE

CT

OR

C

13

37

T1.16

1

T116

PARTIAL SECOND FLOORPLAN - SECTOR C1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 13: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

C

MECHANICAL PLATFORM

A300

PLAN SYMBOL LEGEND

W

DUAL DATA LOCATION. PROVIDE (2) CATEGORY 6A BLUE CABLES.

SINGLE DATA LOCATION FOR CCTV MOUNT AT 15'-0" UNLESS

OTHERWISE NOTED. PROVIDE (1) CATEGORY 6A BLUE CABLE.

WIRELESS ACCESS POINT. (2) CATEGORY 6A YELLOW CABLE.

COIL 20' SLACK LOOP AT LOCATION INDICATED. TERMINATE IN

2-PORT MODULAR JACK BOX AMP # 1116697-1 OR EQUAL. CEILING

MOUNTED UNLESS OTHERWISE NOTED.

TRIPLE DATA LOCATION, (3) CATEGORY 6A BLUE CABLES.

CEILING MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES. REFER TO ARCHITECT REFLECTED CEILING PLAN FOR

EXACT PLACEMENT.

WALL MOUNT PAGING SPEAKER PROVIDE 18AWG GRAY SHIELDED

TWISTED PAIR CABLE. UP TO 10 SPEAKERS MAY BE CONNECTED IN

SERIES.

CAMERA LOCATION AT 16' AFF FOR EXTERIOR, CEILING MOUNT FOR

INTERIOR. PROVIDE (1) CATEGORY 6A GREEN CABLE. PROVIDE WP

COVER AND COIL 12" SLACK IN EXTERIOR BOXES.

CEILING MOUNTED VOICE RE-ENFORCEMENT SPEAKER. REFER TO

ARCHITECT REFLECTED CEILING PLAN FOR EXACT PLACEMENT.

K

DOOR CONTACT - PROVIDE 1/2" CONDUIT TO DOOR FRAME. INSTALL

OWNER FURNISHED ORANGE 22/2 CABLE TO THE SECURITY PANEL

OR ZONE EXPANDER.

ACCESS PINPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG BOX AT

+48" AFF. INSTALL OWNER FURNISHED ORANGE 22AWG 3-PAIR,

CONNECT-AIR OR APPROVED TO THE ACCESS PANEL OR ZONE

EXPANDER. REFER TO KEYED NOTE FOR PINPAD TYPE. PIN PAD

LOCATIONS MUST BE SEPARATED BY A MINIMUM OF 12" O.C. TO

PREVENT FALSE CARD READS.

MOTION SENSOR -PROVIDE 1/2" CONDUIT TO SINGLE GANG BOX AT

+108" AFF. INSTALL OWNER FURNISHED ORANGE 22/4 TO THE

INTRUSION PANEL OR ZONE EXPANDER.

CARD READER - PROVIDE 3/4" CONDUIT TO SINGLE GANG BOX AT +48"

AFF. COORDINATE DEVICES PLACEMENT WITH DOOR INSTALLER AS

SOME DEVICES MAY BE LOCATED ON DOOR MULLIONS. INSTALL OWNER

FURNISHED ORANGE 22AWG 4-PAIR SHIELDED TO THE ACCESS PANEL.

C

SECURITY SYSTEM SIREN, INSTALL OWNER FURNISHED ORANGE

16/2 TO INTRUSION PANEL

S

24x24 CEILING ENCLOSURE FOR AV/PAGING/CONTROLS. PROVIDE (4)

CATEGORY 6A CABLES TO NEAREST TELECOM ROOM.

PRESENTER LOCATION. PROVIDE (1) PRE-TERMINATED MINI-AUDIO,

VGA VIDEO CABLE TO SHORT THROW PROJECTOR. PROVIDE (1)

PRE-TERMINATED HDMI CABLE TO SHORT THROW PROJECTOR AND

LCD FLAT PANEL.

OWNER FURNISHED SHORT THROW DISPLAY. INSTALL OWNER

FURNISHED PROJECTOR AND MOUNT. PROVIDE (1) CATEGORY 6A BLUE

CABLE TO THE NEAREST IDF/MDF. SEE TELECOM DETAILS.

K

DMP SECURITY KEYPAD PROVIDE 1/2" CONDUIT TO DOUBLE GANG

BOX AT +48" AFF. INSTALL OWNER FURNISHED ORANGE 18/4 TO THE

SECURITY PANEL.

M

D

8-BUTTON AMX KEYPAD CONTROL AND CALL BUTTON. CONNECT TO

ADJACENT CATEGORY 5E GRAY CABLE TO NEAREST CLASSROOM

8-BUTTON AMX KEYPAD OR AS NOTED.

SURFACE MOUNTED 12" ANALOG CLOCK AT 96" AFF. UNLESS

OTHERWISE NOTED

CEILING MOUNTED IR SENSOR FOR CLASSROOM SOUND SYSTEMS.

PROVIDE CATEGORY 6 CABLE TO THE CLASSROOM AMPLIFIER.

IR

CEILING MOUNT INTERCOM SPEAKER PROVIDE 22/4 GRAY SHIELDED

CABLE TO THE AMX ENCLOSURE OR NEAREST IDF/MDF ROOM.

REFER TO ARCHITECT REFLECTED CEILING PLAN FOR EXACT

PLACEMENT.

I

OWNER FURNISHED CONTRACTOR INSTALLED 47" LCD TV AND

MOUNT, UNLESS OTHERWISE NOTED. PROVIDE (2) CATEGORY 6A

CABLES. PROVIDE AMX DIGITAL SIGNAGE PLAYER, ATTACH TO REAR

OF OFCI LCD.

1. PROVIDE PROTECTIVE NON-METALLIC COVER

2. ARMING/DISARMING KEYPAD LOCATION, GREY. HID5355AGK09.

3. DOOR CONTROL KEYPAD LOCATION, WHITE. HID5355ABK09.

4. LOCK DOWN INITIATION BUTTON.

5. PROVIDE RACEWAY TO ACCESSIBLE CEILING SPACE IN B115

6. PROVIDE 12X12X4 BACKBOX AND 1/2" C. TO ACCESSIBLE SPACE

FOR WALL MOUNTED PAGING SPEAKER AT 108" AFF, UNLESS

NOTED.

7. FLOORBOX LOCATION. CONNECT HDMI AND VGA TO

PRESENTER LOCATION. PROVIDE (2) CAT 6A CABLES TO MDF.

8. REFER TO ARCHITECT ELEVATIONS FOR DEVICE PLACEMENT

ON MEDIA CENTER WALL.

9. MULTI-PURPOSE VIDEO CONNECTION.

10. TORMAX MOTORIZED SLIDING DOOR, PROVIDE DOOR

CONTACTS AND CONNECTION.

11. HOMERUN CATEGORY 5E GREY CABLE FROM 8-BUTTON

KEYPAD TO NEAREST NX-12OO CONTROLLER.

12. PROVIDE CAT 6A TO NEAREST TELECOM ROOM. INSTALL

OWNER FURNISHED MOUNT AND LCD TV.

13. DOORS SHALL BE CONNECTED TO A TIMED UNLOCK.

14. MAGNETICALLY HELD DOOR, 18/2 ORANGE TO NEAREST

ACCESS CONTROL PANEL, HOLD OPEN POWER SUPPLY AND

MAGNETIC DOOR HOLDER BY ELECTRICAL AND DIVISION 8.

LOCATE POWER SUPPLY IN MDF AS SHOWN ON DETAIL 1 OF

SHEET T5.01.

15. NOT USED.

KEYED NOTES: -

1. CCTV SECURITY CAMERAS AS SHOWN CABLING AND ROUGH IN

ONLY. CAMERA, HARDWARE AND SOFTWARE IS BY OTHERS.

2. CLASSROOM SOUND SYSTEMS INCLUDE A CEILING OR WALL

MOUNTED INFRA RED SENSOR. PROVIDED 1 PER EQUIPPED

ROOM. COORDINATE WITH ARCHITECT REFLECTED CEILING

PLANS, AVOID PLACEMENT WHERE INTERFERENCE FROM

OTHER CLASSROOM SPACES WILL OCCUR.

3. PROVIDE (1) 20AWG 4 CONDUCTOR CABLE BETWEEN

MOTORIZED SHADE CONTROLLERS . PROVIDE (1) 20 AWG 4

CONDUCTOR FROM SHADE GROUP CONTROLLERS TO THE

NEAREST ACCESS CONTROL PANEL.

4. ALL EXTERIOR DOORS SHALL RECEIVE A DOOR POSITION

INDICATOR (DOOR CONTACT) WITH 22AWG 2 CONDUCTOR

ORANGE CABLE TO THE NEAREST ACCESS PANEL

5. PROVIDE (2) 2" SLEEVE FROM CORRIDORS TO EACH

CLASSROOM CEILING SPACE FOR DATA AND INTERCOM

CABLING.

6. PROVIDE (1) 2" SLEEVE FROM CORRIDORS TO EACH STAFF

OFFICE, WORK AREA AND AS REQUIRED FOR PATHWAY FOR

INTERCOM AND DATA LOCATIONS.

GENERAL NOTES: -

X

ME

ZZ

AN

IN

E F

LO

OR

P

LA

N -

SE

CT

OR

A

13

37

T1.17

1

T117

PARTIAL MEZZANINE FLOORPLAN - SECTOR A1/8" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 14: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

B125

Room

B126

MECH STAIR

A218

IDF

A219

A220

MECHANICAL

PLATFORM

1

T501

PARTIAL FIRST FLOOR PLAN MDF 13/4" = 1'-0"

2

T501

PARTIAL SECOND FLOOR PLAN IDF.23/4" = 1'-0"

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

A B

C

KEY PLAN

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

PA

RT

IA

L F

LO

OR

PLA

NS

TE

LE

CO

M

RO

OM

S

T5.01

3

T501

PARTIAL SECOND FLOOR PLAN IDF.33/4" = 1'-0"

Page 15: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

1

T701

TELECOM FACEPLATE DETAILNTS

4

T701

SHORT THROW PROJECTOR MOUNTNTS

7

T701

TELECOMMUNICATIONS RACEWAY AND BACKBOXESNTS

2

T701

AV DETAILSNTS

3

T701

AV RACEWAYNTS

5

T701

PROJECTOR CONNECTION DETAILSNTS

6

T701

AMX KEYPAD/CALL BUTTONNTS

8

T701

UC DISPLAY RACEWAYNTS

RA

CE

WA

Y A

ND

F

AC

EP

LA

TE

DE

TA

ILS

13

37

T7.01

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#

:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eug

ene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

3

T701

AV RACEWAYNTS

Page 16: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

T7.02

TE

LE

CO

M

DE

TA

ILS

13

37

1

T702

PAGING/MASS NOTIFICATION LINE DIAGRAMNTS

3

T702

COPPER RISER DIAGRAMNTS

2

T702

FIBER RISER DIAGRAMNTS

4

T702

ISLAND LOCATION RACEWAY 1ST FLOORNTS

6

T702

CLASSROOM AV SINGLE LINE DIAGRAMTYPICAL OF ALL CLASSROOMS

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

5

T702

TYPICAL POWER/DATA/AV FLOORBOXNTS

7

T702

ISLAND LOCATION RACEWAY 2ND FLOORNTS

8

T702

TYPICAL AMX ENCLOSURE FACEPLATESNTS

Page 17: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

1

T703

DOOR SECURITY CABLE REQUIREMENTS - COORDINATE WITH DIVISION 8NTS

2

T703

SECURITY AND ACCESS SYSTEM ONELINE DIAGRAMNTS

3

T703

MISCELLANEOUS DEVICE CABLINGNTS

4

T703

CLASSROOM GLOBAL SHADE CONTROL VIA LENEL CONTACTSNTS

T7.03

TE

LE

CO

M

DE

TA

ILS

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene S

choo

l D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM

Page 18: AV100 - Eugene School District LEGEND DESCRIPTION MANUFACTURER PART NUMBER CS X CONTROL \ 匀䔀刀䤀䄀䰀尩 BELDEN 9451 CR X CONTROL \ 䤀刀尩 BELDEN 9451 CG X CONTROL \ 䜀䔀一䔀刀䄀䰀尩

1

T704

DOOR SECURITY CABLE REQUIREMENTS - ELECTRONIC PANICNTS

7

T703

LENEL 1320 - CARD READER WITH ARM/DISARM KEYPADNTS

3

T704

ADA DOOR INTERFACE MODULE WIRING, (TYP)NTS

9

T703

LENEL 1320 - CARD READER/KEYPAD FOR DOOR CONTROLNTS

4

T704

MOTION SENSOR CABLINGNTS

2

T703

SIREN CABLINGNTS

8

T703

LENEL 1320 - SLIDING DOOR INTERFACENTS

5

T704

CARD READER CABLINGNTS

6

T704

TYPICAL ACCESS PANEL LAYOUTNTS

T7.04

TE

LE

CO

M

DE

TA

ILS

13

37

RE

VIS

IO

NS

:

CH

EC

KE

D:

PR

OJE

CT

#:

IS

SU

E D

AT

E:

DR

AW

N:

20

15

P

IV

OT

A

RC

HIT

EC

TU

RE

C

Eu

gene

S

cho

ol D

istrict

BID

D

OC

UM

EN

T S

ET

River R

oad / E

l C

am

ino del R

io E

lem

entary

44

W

. B

RO

AD

WA

Y S

T. E

UG

EN

E, O

RE

GO

N

13

37

.0

0

10

F

EB

2

01

6

DD

H

GE

S

NO

RT

HW

ES

T I

NFO

RM

AT

ION

SE

RV

ICE

S49

00 S

W G

RIF

FIT

H D

RIV

E, S

UIT

E 2

50B

EA

VE

RT

ON

, OR

EG

ON

970

08P

HO

NE

:(50

3)24

6-85

85 W

WW

.NIS

PD

X.C

OM