automated enzyme immunoassay analyzer · tosoh bioscience, inc. 6000 shoreline court, suite 101...
TRANSCRIPT
AUTOMATED ENZYME IMMUNOASSAY ANALYZER
Tosoh Result Integrity • Multi-Tasking Efficiency
TOSOH BIOSCIENCEwww.tosohbioscience.us
®
Four Configurations Provide Expansion Capabilities
AIA-900with 9 Tray Sorter
AIA-900Loader Model
AIA-900Benchtop
AIA-900with 19 Tray Sorter
Features:
• 90 tests/hour throughput
• First result in ~ 18 minutes
• Random access / Continuous processing
• 90 day calibration for most assays
• Simple touch screen operation
• Bar-coded primary tube sampling
• Clot detection
• Automated pretreatment
• Automated dilution from 2 to 1000
®
Four Configurations for Different Sizes of Labs and Workloads
9 tray sorter
19 tray sorter
Loader Model
Benchtop
• 90 tests/hour throughput• Load 9 trays (20 cups/tray)• Load 10 sample racks• Load 100 patient samples• Increased walkaway time with loading 180 test cups
Dimensions - W/D/H: 50.79” x 26.18” x 49.09”1290 mm x 665 mm x 1247 mm
AIA-900with 9 Tray Sorter
AIA-900
AIA-900
Loader Model
Benchtop
• 90 tests/hour throughput• Load 10 racks on board• Load up to 5 tests/patient
• 90 tests/hour throughput• Load 10 racks on board• Load up to 5 tests/patient
Dimensions - W/D/H: 35.04” x 26.18” x 49.09”890 mm x 665 mm x 1247 mm
Dimensions - W/D/H: 40” x 26.18” x 30”1016 mm x 665 mm x 762 mm
• 90 tests/hour throughput• Load 19 trays (20 cups/tray)• Maximize walkaway time with loading 380 test cups• Load 10 sample racks • Load 100 patient samples
Dimensions - W/D/H: 59.84” x 26.18” x 49.09”1520 mm x 665 mm x 1247 mm
AIA-900with 19 Tray Sorter
Substrate II
SecondaryReagents
Sample Loader
Load tubes for Sorter Models
Self-contained reagent storage
Optional 19 Tray Sorter9 Tray Sorter also availableLoad cups and tubes for Loader Model
Tips
• Types: 100 mL & 5 mL• Variable Configurations
• 2 Racks, 96 Tips • 192 Tips Total
B/F Probes On-board Printer
Touch ScreenMonitor
®
Unit Dose Test Cup Reagent Technology
The AIA-PACK® test cup format works with every Tosoh AIA Automated Immunoassay System. Reagents are interchangeable, so laboratories with more than one Tosoh system can use the same reagents. Transition between systems is seamless, ensuring consistent results and efficient, economical operation for the laboratory.
It is very easy for a lab to add a 9 or 19 tray sorter to the instrument. The reagent’s performance does not change since the analysis section of the instrument remains
unchanged.
Automated Inventory Management Screens
Changing Reagents
Secondary Reagents
Test Cup Inventory
Daily Maintenance Weekly Monthly
The AIA-900 requires minimal maintenance
Tosoh Bioscience, Inc.6000 Shoreline Court, Suite 101South San Francisco, CA 94080Tel: (800) 248-6764Fax: (650) 615-0415www.tosohbioscience.us
Part
# 01
77-9
0-03
16
TOSOH BIOSCIENCE
AIA-900 SpecificationsPrinciple of measurement Fluorescent enzyme immunoassay (FEIA) method
Processing method Fully automated continuous random access
Processing ability Max. 90 tests/hour (ST reagent)
Specimen quantity 10 - 125 μL
Specimen clogging detection Pressure detection method
Measurement condition Reaction temperature: 37°C
Reaction time Antigen-antibody reaction time: 10 minutes, 20 minutes, 40 minutes
Specimen dilution function Dilution ratios between 2 and 1000 can be selected for each assay
Detection method Fluorescent measurement (top-top method)
Number of sample rack sets Max. 10
Number of samples and reagent cups Max. 100
Specimen containers 13 × 75 mm, 13 × 100 mm, 16 × 75 mm, 16 × 100 mm (O.D. × length of test tube) Dedicated sample cups
Specimen barcode Supports CODE39, CODE128, ITF, NW-7, JAN/EAN/UPC, industrial 2of5, and COOP2of5
Sample tip Dedicated tip
Number of installed sample tips Max. 192 tips (96 tips/rack in 2 racks)
Number of reagent sets Max. number of reagent vials: 12, Max. number of reagent bottles: 4
External output RS232C
Power source/consumption 100 - 240 VAC, 50/60 Hz, 300 VA
External dimensions AIA-900 Benchtop- W/D/H: (Dimensions include revolving carousel) 40” x 26.18” x 30”; 1016 mm x 665 mm x 762 mm AIA-900 Loader Model - W/D/H: (Dimensions include analyzer/sorter stand) 35.04” x 26.18” x 49.09”; 890 mm x 665 mm x 1247 mm
AIA-900 with 9 Tray Sorter - W/D/H: (Dimensions include analyzer/sorter stand) 50.79” x 26.18” x 49.09”; 1290 mm x 665 mm x 1247 mm
AIA-900 with 19 Tray Sorter - W/D/H: (Dimensions include analyzer/sorter stand) 59.84” x 26.18” x 49.09”; 1520 mm x 665 mm x 1247 mm
Temperature 15 °C - 30 °C (degrees Celsius)
Humidity 40 % - 80 % R.H. (non-condensing)
EMC standard IEC61326-1: 2005, IEC61326-2-6: 2005
“AIA-PACK” and “AIA” are the registered trademarks of Tosoh Corporation in United States, Canada, etc.