attitude and heading reference systemsimg.tradekey.com/images/uploadedimages/brochures/3/... ·...

14
FY-AHRS-2000B Installation Instructions Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0 Guilin FeiYu Electronic Technology Co., Ltd Addr: Rm. B305,Innovation Building, Information Industry Park ,ChaoYang Road ,Qi Xing District ,Guilin China Website: http://www.feiyudz.cn E-mail: [email protected]

Upload: others

Post on 18-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Attitude and Heading Reference Systems

FY-AHRS-2000B

Installation Instructions V1.0

Guilin FeiYu Electronic Technology Co., Ltd

Addr: Rm. B305,Innovation Building, Information Industry Park ,ChaoYang

Road ,Qi Xing District ,Guilin China

Website: http://www.feiyudz.cn

E-mail: [email protected]

Page 2: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

1

Dear customers:

Hello! Thank you for using the products of Guilin Feiyu Electronic Technology Co,

Ltd. Please carefully read the instructions to ensure the proper use and operation.

Page 3: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

2

FY-AHRS-2000B Installation Instructions

FY-AHRS-2000B is a high-performance strap down inertial navigation system that can

measure any point of orientation of the entire locomotive and vehicle in the 3D space. AHRS

could make high-precision positioning for any stationary or moving objects with angular velocity,

even short magnetic interference will not affect the heading accuracy of the AHRS. The system

can be carried out AHRS magnetic field calibration, to eliminate the hard and soft iron materials

motorcycles offset caused by magnetic fields.

Features:

1、Using high-performance all solid-state three-axis accelerometer, three-axis angular rate

sensors and three-axis magnetic field sensor.

2、Three axis 360-degree all-dimensional output of the attitude and heading, attitude and heading

data on a static accuracy of less than 0.5 degrees, the dynamic accuracy of less than 2

degrees.

3、 Built-in sensor auto-calibrate, can automatically compensate for the interference of

temperature drift, noise, external magnetic field, etc.

4、Super long time stability and fast dynamic response.

Application:

Ground Transportation

Robots

Aircraft

Video Camera ect.

The AHRS includes three gyroscopes, three accelerometers and three magnetic field

meters. Real-time measure three axial angular velocity, acceleration, and magnetic field strength.

After the processing by the internal microprocessor, the AHRS outputs drift-free attitude and

heading information, the three-dimensional acceleration, three-dimensional angular velocity,

three-dimensional geomagnetic field, which have been compared and checked-off.

Page 4: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

3

1. Dimensions and Interface Description:

Dimensions:

Interface:

2. Performance Parameter

Specification FY-AHRS-2000B Remark

Performance

Refresh Rate(Hz) 1~100 The default refresh rate is 20Hz

Initialization Time(sec) 3

Heading

Output Range(deg) 0~360

length(mm) width(mm) height(mm)

45 25 11

Black cable Red cable Yellow cable Green cable

GND +5V RX TX

Page 5: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

4

Accuracy(deg) ±1 Compensation and Correction

Resolution(deg) 0.1

Attitude

Roll output range(deg) ±180

Pitch output range(deg) ±90

Static Accuracy(deg) <0.5

Dynamic Accuracy(deg RMS) <2

Resolution(deg) 0.05

Angular velocity

Roll, Pitch ,Heading(deg/sec) <2000 Optional range of different

Resolution(deg/sec) <0.05

Bandwidth(Hz) 100

Linear Acceleration

X, Y, Z axis measuring range(g) ±3

Deviation(mg RMS) 0.3

Bandwidth(Hz) 40

Magnetic field

X, Y, Z axis measuring range(gauss) ±1.5

Output range -2048~2047 0.769 MG/LSB

Bandwidth(Hz) 20

Environmental Indicators

Working temperature(℃) -40~+70

Electrical indicators

Input Voltage(V) 3.3V~6V Recommended 5V

Input Current(mA) <80

Digital Output TTL or RS232

(Optional)

Baud rate of output 4800~115200 The default baud rate is 19200

Physical index

Size(mm) 45×25×11 Length ×width× height

Weight(g) 18

Page 6: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

5

3、Hardware Installation

FY-AHRS-2000B should be installed on a stable platform; the installation of the surface

should be parallel with the ground as far as possible when still placed on the platform, and keep

it away from the magnetic field effects as far as possible. Magnetic objects must avoid being

included. For example: car engines, electric motors, audio speakers, steel, iron and steel nuts or

bolts. We recommend using copper, plastic or aluminum as the FY-AHRS-2000B installation and

packaging materials. Because it equipped with a gyro and acceleration sensor, so we must fix it

on the platform cautiously.

When install FY-AHRS-2000B, make ensure that the "forward" on the shell (it means the

positive X-axis) keep the same direction with the platform move forward straight. This is very

important. Once the installation is finished, you’d better make ensure that no more change in use.

Since magnetic interference may exist in the surroundings, for realize the correction of

course, we advised that please run the magnetic field compensate program of the

FY-AHRS-2000B after each time the environment changed .We must select the install position

carefully when install the FY-AHRS-2000B.The selected position should expose the electronic

component fully to the Earth's magnetic field, while keep it relatively isolated from the magnetic

field effects and interference.

FY-AHRS-2000B includes gyroscopes and accelerometers, in order to initialize the sensors,

you should keep it horizontal and static for about 3 to 5 seconds when Power-on. If you

power-on it during movement, it may cause the attitude data accuracy decline.

If the external environment changed so much, when boot and maintain the stationary state,

the gyroscope angular rate is greater than 1 ° per second, please perform "configuration" - ""

gyro to initialize ".

4、 Power and Signal Connections

FY-AHRS-2000B connects to the user equipment through standard TTL serial protocol, so

if you are using a notebook computer, please prepare a USB-serial converter. FY-AHRS-2000B

factory default serial port baud rate is 19200, the output data refresh rate is 20Hz.

Recommended operating voltage is 5V DC power input. The voltage input range is 3.3V ~

6V, if the supply voltage is out of the range, the AHRS will be damaged or caused performance

reduction.

5、Demo Software Installation and Use

The demo software program's document of FY-AHRS-2000B is AHRS test software.exe,

after completing the installation, the interface is as follows:

Page 7: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

6

Select the serial port used to connect in the "Port" field, such as: "COM1"; in the "Rate"

field select the baud rate as "19200"; FY-AHRS-2000B connected to the default wave special

rate of 19200, a start-byte, 8 data bytes, a Stop byte, no parity, either hardware or software no

"handshake." Baud rate can be changed by command.

Click "Open Serial Port" button, if the FY-AHRS-2000B has been powered on and in

working status, you will see the attitude, angular rate and other parameters displayed on the left

window. After click "Graphic Demo" button, the 3D graphics demo window will be pop-up.

Page 8: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

7

The three-dimensional rectangular in the demo program will change its attitude accordingly thought the

change attitude of the FY-AHRS-2000B .

Select the menu "Show" - “electronic compass display ", you can switch to two dimensions

compass view, it will indicating the real time course.

Page 9: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

8

At the main interface of AHRS testing software, you can configure the output serial baud

rate, the output data refresh rate, the output data content, etc, and you also can set the baseline

calibration and the magnetic field calibration of the sensors inside the FY-AHRS-2000B .

6、Magnetic field calibration

FY-AHRS-2000B will be started magnetic compensation calibration procedures once the

installation finished. The magnetic field compensation process in the module's firmware

determines the magnetic field calibration impact of the installation of platform, so even if the

FY-AHRS-2000B is installed on the steel device (for example, a vehicle), it still can provide

accurate readings. FY-AHRS-2000B has the compensation effect only in a limited interference

range. Range value of magnetometer is between minus 100 and plus 100 m-Teslas which is

approximately twice the magnetic force in middle latitude northern hemisphere, If the

disturbance value of the magnetic field more than plus or minus 50 m-Teslas, the magnetometer

could reach saturation and block compensation.

Magnetic compensation function is semi-automatic. Once started, FY-AHRS-2000B will

collect data automatically from every position of the circumference. After completing this work,

the module will calculate the correction factor to compensate for the near magnetic field

abnormalities, and to store the corrected value in the permanent memory. After the compensation

process, the corrected value will be merged into the subsequent azimuth data.

Page 10: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

9

If necessary, the compensation process can be repeated several times. When began to run

the test program, please note: The magnetic objects (such as the nearby mobile phones, structural

steel and buried underground pipelines) may lead to azimuth errors. If the FY-AHRS-2000B is

installed in a vehicle, it will encounter the magnetic field anomaly; this is why there is a

magnetic compensation procedure. However, for some bulky magnetic properties are very likely

to distort the earth’s magnetic field, even the process of magnetic compensation happened in a

long distance.

Magnetic declination and bias of installation is the most important parameter values, which

can be entered into the module by the host. Usually, when power-on, the module will

automatically set the value of magnetic declination and bias to 0. This can be changed through

software commands, and the value is still valid after restarted.

Magnetic declination (also known as magnetic variable) is the angle between true north and

magnetic north. Azimuth bias is defined as the level angle deviation between the module's

forward axis (X axis) and the reference axis of installation platforms. Azimuth bias is a constant,

which is decided the module mechanical placement and installation elements. Magnetic

declination and Azimuth bias will affect the accuracy of the Azimuth observation. The module

should use these two corrected values, and add it to the magnetic field course deviation angle

correction option.

According to usual practice, both the mark symbol of magnetic declination and azimuth

bias used in the east are belonging to positive sign. For example, if magnetic north is the east of

true north, magnetic declination is positive. For example, the local magnetic declination is -6 °,

the install bias is -2 °, and then the magnetic field course deviation angle correction option

should fill in the 8 °.

Choosing menu "configuration"-> "magnetic calibration procedures", the magnetic

compensation procedures will be start, at the same time, the process and longitude of the

program operation would be shown on the bottom of the main procedures information displayed

window. Magnetic compensation is used to confirm the magnetic attribute of surrounding

environment, and obtaining the factor which is used to compensate the magnetic. If lack of this

amended procedure, the substantial azimuth angle error may occur.

In the implementation of the "Start calibration of XY-axis magnetic field", you need to place

FY-AHRS-2000B horizontally (the X-Y plane of FY-AHRS-2000B is parallel with the ground

level. At the same time, the right side of Z-axis being faced down with the ground water level

vertically), and rotate the module clockwise, keep it stable circular movement. If the

FY-AHRS-2000B is installed in a vehicle, the above steps are completed by rotate the vehicles

slowly on the horizontal ground.

Page 11: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

10

The magnetic field calibration process will show the current rotation angle by drawing the

circle. You must clockwise rotate FY-AHRS-2000B continuously until the end of the

amendment.

If the drawn circumference is significantly distortion, it may be coursed by the overlarge

external magnetic interference or there are problems in the process of rotation, so you must

re-calibrate.

By the end of the magnetic field calibration, click "Write FLASH” button, it will write the

amend parameters in the FLASH and keep them permanently. At the same installation platform,

if the external environment is not change too much, one time amendment will be enough.

FY-AHRS-2000B Interface Protocol

FY-AHRS-2000B Data output format description (standard RS-232, TTL, ASCII character

output):

Command head, field1, field 2, field 3, • • • • • •, the field n * checksum field (CRLF)

Between the fields with "," separated, each with a carriage return line feed end of the data.

FY-AHRS-2000B attitude data format

Page 12: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

11

Command

type

Command

head

Field 1 field 2 field 3 field 4 field 5 field 6

attitude data $FYZT Pitch Roll heading X

angular

rate

Y

angular

rate

Z

angular

rate

field 7 field 8 field 9 field 10 field 11 field 12 field 13 Check

X

acceleration

Y

acceleration

Z

acceleration

resultant

acceleration

X

magnetic

field

Y

magnetic

field

Z

magnetic

field

* Check

value

FY-AHRS-2000B attitude data output example:

$FYZT,-0.92,-0.60,341.77,-0.15,0.14,0.11,0.02,-0.01,1.00,1.00,447.19,140.02,159.50*F4

Check value calculation method: arithmetic accumulate all data by-byte start from each "$" of

the data symbols (including the $) to the"*" (excluding “*”).

FY-AHRS-2000B Configuration Format Description (standard RS-232,TTL, ASCII

character input):

Command head, command NO, parameter1, parameter2,……,parameter n (CRLF).

Between the fields with "," separated, with a carriage return line feed end of each data.

Command

type

Command

head

Command

NO

Parameter

1

Parameter

2

parameter

3

parameter

4

Configure the

output refresh

rate

$Config 6 Refresh rate

settings,

Parameter setting

range

1 — 100

1, 100Hz

2, 50Hz

5, 20Hz

10, 10Hz

100,1Hz

NULL NULL NULL

Configure the

output baudrate

$Config 7 Baudrate

settings,

Parameter setting

range

0 — 7

NULL NULL NULL

Page 13: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

12

0,4800

1,9600

2,14400

3,19200

4,38400

5,56000

6,57600

7,115200

Configure

magnetic

declination

$Config 4 Setting of the

magnetic

declination,

Parameter setting

range

-360 — 360

For setting the

magnetic

deviation angle

and installed

heading bias

NULL NULL NULL

Open/Close the

FY-AHRS-200

0B serial data

output

$Config 9 Parameter setting

range

0 — 1

0,close

1,open

NULL NULL NULL

magnetic field

calibration

$Config 10 The magnetic field

calibration options

1 — 2

1,Start calibration

XY-axis magnetic

field

2,Reserved.

After sending this

command, you

must clockwise

rotate

FY-AHRS-2000B

horizontally to

complete the

magnetic field

NULL NULL NULL

Page 14: Attitude and Heading Reference Systemsimg.tradekey.com/images/uploadedimages/brochures/3/... · Attitude and Heading Reference Systems FY-AHRS-2000B Installation Instructions V1.0

FY-AHRS-2000B Installation Instructions

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

13

FY-AHRS-2000B attitude configure command example:

$Config,9,1 (CRLF)

Open the FY-AHRS-2000B serial data output

$Config,4,16 (CRLF)

Configure the FY-AHRS-2000B magnetic field deviation angle of 16 degrees.

$Config,99,1(CRLF)

Write the configuration information to the FLASH.

Attention: If there is any change of the configuration parameters, you must click "Write

FLASH" button, or choose menu "configuration"->"permanent preserve configuration

parameters", to write the configuration to FLASH and permanent preserve, or next time

power up, these configuration parameter will be lost.

-----END------

Note: We reserve the right to change this manual at any time! And the newest edition will be

shown on our website.

calibration

write the

configuration

information

in the FLASH

$Config 99 It is fixed at 1

Once configured,

send this command

to write the

configuration

information in the

FLASH

NULL NULL NULL