Assessment of Potenal Flow Restricons in Curb-inlets with Channel-extensions Background Presenter: Muhammad Ashraf Conclusions The new TxDOT standard precast curb inlet (Type PCO) consists of a main bay and side extension channels For a compact design, the cross-secon of the extension channel is significantly smaller than the inlet opening Research Objecve Future Research Quanfy the effects of channel extensions on intercepon capacity of inlets on-grade and in a sag Construct a full-scale physical model of the curb inlet Test the model with and without restricted extensions Methodology However, capacity of a standard inlet is significantly lower than predicted by HEC-22 (endorsed by FHWA) Frank E. Schalla Dr. Ben Hodges, UT Ausn Prof. Michael Barre, UT Ausn Center for Transportaon Research Texas Department of Transportaon A 10-ſt PCO on-grade is equivalent to a standard inlet HEC-22 overesmates intercepon of inlets on-grade under most condions Propose new modificaons to HEC-22 equaons Acknowledgements Reducon in cross-secon area may decrease the inlet’s intercepon capacity Underperforming inlets increase the hazards of flooding and vehicle hydroplaning Problem Statement Inlet on-grade: Similar performance was observed for standard and PCO inlets Inlet in a sag: Sharp drop in inlet performance as depth approached inlet opening height (6’’) The extension performs at 20% of predicted by HEC-22; 10-ſt and 15-ſt PCO inlets will perform at 58% and 47% Results and Discussion PCO-type inlets in a sag have drascally less capacity compared to standard inlets Increasing the extension connecon area of inlets in a sag can potenally increase intercepon capacity

Upload: others

Post on 01-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Assessment of Potential Flow Restrictions in urbinlets ...ctr.utexas.edu/wp-content/uploads/2018CTRsymp-muhammad-ashra… · Assessment of Potential Flow Restrictions in urb-inlets

Assessment of Potential Flow Restrictions in Curb-inlets with Channel-extensions

Background

Presenter: Muhammad Ashraf

Conclusions

The new TxDOT standard precast curb inlet (Type PCO) consists of a main bay and side extension channels

For a compact design, the cross-section of the extension channel is significantly smaller than the inlet opening

Research Objective

Future Research

Quantify the effects of channel extensions on interception capacity of inlets on-grade and in a sag

Construct a full-scale physical model of the curb inlet

Test the model with and without restricted extensions

Methodology

However, capacity of a standard inlet is significantly lower than predicted by HEC-22 (endorsed by FHWA)

Frank E. Schalla Dr. Ben Hodges, UT Austin Prof. Michael Barrett, UT Austin Center for Transportation Research Texas Department of Transportation

A 10-ft PCO on-grade is equivalent to a standard inlet

HEC-22 overestimates interception of inlets on-grade under most conditions

Propose new modifications to HEC-22 equations

Acknowledgements

Reduction in cross-section area may decrease the inlet’s interception capacity

Underperforming inlets increase the hazards of flooding and vehicle hydroplaning

Problem Statement

Inlet on-grade: Similar performance was observed for standard and PCO inlets

Inlet in a sag: Sharp drop in inlet performance as depth approached inlet opening height (6’’)

The extension performs at 20% of predicted by HEC-22; 10-ft and 15-ft PCO inlets will perform at 58% and 47%

Results and Discussion

PCO-type inlets in a sag have drastically less capacity compared to standard inlets

Increasing the extension connection area of inlets in a sag can potentially increase interception capacity