Masterpact NT/NWLV power air circuit breakersDescriptive price list

05April

MGLV5705 MASTERPACT(April'05) 22/2/05 3:36 pm Page 1

Contents

Section 1 Masterpact NT Page

Masterpact NT overview and characteristics 4

Masterpact NT standard specification 11

Masterpact NT fixed versions 12

Circuit breakers and control units 12

Connection terminals 13

Indication contacts 14

Remote operation 15

Masterpact NT drawout versions 16

Circuit breakers and control units 16

Chassis connection terminals 17

Chassis locking and accessories 18

Indication contacts 19

Remote operation 20

Masterpact NT fixed and drawout accessories 21

Masterpact NT fixed and drawout switch disconnectors 23

Switch disconnectors 23

Connection terminals and accessories 24

Drawout switch disconnectors 25

Chassis connection terminals 26

Masterpact NT communications accessories 27

Masterpact NT order form 28

Lasr year saw the introduction of the Masterpact NT as an addition to the

Masterpact NW range offering familiar features such as the Micrologic trip

unit, the stainless steel arc chute filters and the excellent chassis features.

The Masterpact NT also has the additional benefits of being the smallest

ACB in the world offering unrivalled space saving opportunities.

To enable you to take advantage of this new offer, the Masterpact NT and

NW price lists have been amalgamated to offer greater chioce and

flexibility for power breaker applications:

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 2

Section 2 Masterpact NW Page

Masterpact NW standard specification 29

Masterpact NW fixed versions 30

Circuit breakers and control units 30

Connection terminals 31

Indication contacts 32

Remote operation 33

Masterpact NW drawout versions 34

Circuit breakers and control units 34

Chassis connection terminals 35

Chassis locking and accessories 36

Indication contacts 38

Remote operation 39

Masterpact NW fixed and drawout accessories 40

Masterpact NW fixed and drawout switch disconnectors 42

Switch disconnectors 42

Chasis connection terminals and accessories 43

Drawout switch disconnectors 44

Drawout connection terminals 45

Masterpact NW communications accessories 46

Masterpact NW order form 49

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 3

New Masterpact NT,new levels of performance

Masterpact NT 800 to 1600A

Switch disconnector version

The switch disconnectors are derived directly from the circuitbreakers and offer the same features and performance levels.

Once closed, the switch disconnectors are unprotected andbehave like ordinary switches. They are often used for busbarcoupling.

Integration in a communications network

Masterpact can be integrated in a general supervision system tooptimise installation operation and maintenance.

The communication architecture is open and may be upgradedfor interfacing with any protocol.

1000V and 400Hz distribution system

The Masterpact range can be used on 1000V installations(mining industry) and 400Hz systems (aeronautics, computercentres).

Performance levels

L1 - For high current limiting capabilityand a discrimination level (37kA) asyet unequalled by any other circuitbreaker of its type. Intended for theprotection of cable type feeders orto raise the performance level of aswitchboard when the transformerpower rating is increased.

H1 - For industrial sites with high shortcircuit levels or installations withtwo parallel connectedtransformers.

4

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 4

Optimisedvolumes

The smallest circuit breakerin the world

Masterpact NT innovates by offering allthe performance of a power circuitbreaker in an extremely small volume.The 70mm pole pitch means a three poledrawout circuit breaker can be installedin a switchboard section 400mm wideand 400mm deep.

Practical installation solutions

The new range improves upon all theinstallation solutions which have alreadymade Masterpact a success. It has beendesigned to standardise switchboards,optimise volumes and simplifyinstallation:

■ Incoming connection to top or bottomterminals

■ No safety clearance required

■ Connection:

■■ Horizontal or vertical rear connection

■■ Front connection with minimum extra space

■■ Mixed front and rear connections

■ No derating up to 55°C for fixeddevices

5

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 5

6

General overview

Circuit breakers and switch disconnectors■ Ratings:

■■ Masterpact NT 630 to 1600 A

■ Circuit breakers type H1, L1

■ Switch disconnectors type HA

■ 3 or 4 poles

■ Fixed or drawout versions

■ Protection derating

Micrologic control units Ammeter A

2.0 basic protection

5.0 selective protection

6.0 selective + earth-fault protection

7.0 selective + earth-leakage protection

Power meter P

5.0 selective protection

6.0 selective + earth-fault protection

7.0 selective + earth-leakage protection

Harmonic meter H

5.0 selective protection

6.0 selective + earth-fault protection

7.0 selective + earth-leakage protection

Trip unit accessories ■ External sensor for earth-fault protection

■ Rectangular sensor for earth-leakage protection

■ Setting options (long-time rating plug):

■■ Low setting 0.4 to 0.8 x Ir

■■ High setting 0.8 to 1 x Ir

■■ Without long-time protection

■ External power-supply module

■ Battery module

Communication ■ COM option in Masterpact

■ Masterpact in a communication network

Connections ■ Rear connection (horizontal or vertical)

■ Front connection

■ Mixed connections

■ Optional accessories

■■ Bare-cable connectors and connector shields

■■ Terminal shields

■■ Vertical-connection adapters

■■ Cable-lug adapters

■■ Interphase barriers

■■ Spreaders

■■ Disconnectable front-connection adapter

■■ Safety shutters, shutter locking blocks, shutter

position indication and locking

This section describes all the functions

offered by Masterpact NT devices.

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 6

Locking ■ Pushbutton locking by padlockable transparent cover

■ OFF-position locking by padlock or keylock

■ Chassis locking in disconnected position by keylock

■ Chassis locking in connected, disconnected and test positions

■ Door interlock (inhibits door opening with breaker in connected position)

■ Racking interlock (inhibits racking with door open)

■ Racking interlock between crank and OFF pushbutton

■ Automatic spring discharge before breaker removal

■ Mismatch protection

Indication contacts ■ Standard or low-level contacts:

■■ ON/OFF indication (OF)

■■ «fault trip» indication (SDE)

■■ Carriage switches for connected (CE), disconnected (CD) and test (CT) positions

■ Programmable contacts:

■■ 2 contacts (M2C)

■■ 6 contacts (M6C)

Remote operation ■ Remote ON/OFF:

■■ Gear motor

■■ XF closing or MX opening voltage releases

■■ PF ready-to-close contact

■■ Options: RAR automatic or Res electrical remote reset

- BPFE electrical closing pushbutton

■ Remote tripping function:

■■ MN voltage release

- Standard

- Adjustable or non-adjustable delay

■■ Or second MX voltage release

Accessories ■ Auxiliary terminal shield

■ Operation counter

■ Escutcheon

■ Transparent cover for escutcheon

■ Escutcheon blanking plate

7

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 7

8

Circuit breakers and switch disconnectorsNT06 to NT16

Common characteristicsNumber of poles 3/4Rated insulation voltage (V) Ui 1000/1250Impulse withstand voltage (kV) Uimp 12Rated operational voltage (V AC 50/60 Hz) Ue 690Suitability for isolation IEC 60947-2Degree of pollution IEC 60664-1 3

Circuit breaker characteristics as per IEC 60947-2Rated current (A) In at 40°C/50°C*Rating of 4th pole (A)Sensor ratings (A)

Type of circuit breakerUltimate breaking capacity (kA rms) Icu 220/415 VV AC 50/60 Hz 440 V

525 V690 V1000 V

Rated service breaking capacity (kA rms) Ics % IcuRated short-time withstand current (kA rms) Icw 0.5 sV AC 50/60 Hz 3 sIntegrated instantaneous protection (kA peak ±10%)Rated making capacity (kA peak) Icm 220/415 VV AC 50/60 H 440 V

525 V690 V1000 V

Break time (ms)Closing time (ms)Circuit breaker characteristics as per NEMA AB1Breaking capacity (kA) 240 VV AC 50/60 Hz 480 V

600 VSwitch disconnector characteristics as per IEC 60947-3Type of switch disconnectorRated making capacity (kA peak) Icm 220/415 VV AC 50/60 Hz 440 V

500/690 V1000 V

Rated short-time withstand current (kA rms) Icw 0.5 sV AC 50/60 Hz 3 sUltimate breaking capacity (Icu) with external protection relay,Maximum delay 350 msInstallation, connection and maintenanceService life Mechanical With maintenanceC/O cycles x 1000 Without maintenance

Electrical Without maintenance 440 V690 V1000 V

Motor control (AC3-947-4) 690 VConnection Drawout FC

RCFixed FC

RCDimensions (mm) Drawout 3PH x W x D 4P

Fixed 3P4P

Weight (kg) Drawout 3P/4P(approximate) Fixed 3P/4P

* 50°C: rear vertical connected.

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 8

9

NT06 NT08 NT10 NT12 NT16630 800 1000 1250 1600630 800 1000 1250 1600400 400 400 630 800to 630 to 800 to 1000 to 1250 to 1600

H1 L1 H10 H10 H1042 150 - 42 -42 130 - 42 -42 100 - 42 -42 25 - 42 -- - 20 - 20100 % 100 %42 10 20 42 2020 - - 20 -- 1(1) - - -88 330 - 88 -88 286 - 88 -88 220 - 88 -88 52 - 88 -- - 42 - 4225 9 25 25 25< 50 < 50

42 150 - 42 -42 100 - 42 -42 25 - 42 -

HA HA10 HA HA1075 - 75 -75 - 75 -75 - 75 -- 42 - 4242 20 42 2020 - 20 -42 20 42 20

Sensor selectionSensor rating (A) 400 630 800 1000 1250 1600Ir threshold setting (A) 160 to 400 250 to 630 320 to 800 400 to 1000 500 to 1250 640 to 1600

(1) SELLIM system

25 25 25 25 2512.5 12.5 12.5 12.5 12.56 3 - 6 (NT16 : 3) -3 2 - 2 (NT16 : 1) -- - 0.5 - 0.53 2 - 2 (NT16:1) -■ ■ ■ ■ ■■ ■ ■ ■ ■

■ ■ - ■ -■ ■ - ■ -322 x 288 x 280322 x 358 x 280301 x 274 x 211301 x 344 x 21130/3914/18

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 9

10

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 10

Standard specifications

11

Prices shown for circuit breakers and switch disconnectors include:

Fixed

■ 4 changeover auxiliary contacts

■ Door escutcheon

Drawout

■ 4 changeover auxiliary contacts

■ Busbar shutters (padlockable)

■ Arc chute cover

■ Auxiliary terminal shield

■ Mismatch protection

■ Door interlock

■ Door escutcheon

■ Racking handle

All circuit and switch disconnectors are complete with:

■ Manual open/close pushbuttons

■ Hand charged stored energy operating mechanism

Section 1 Masterpact NT

NT

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 11

12

NT06 to NT16Fixed circuit breakersCircuit breaker selection

Basic circuit breakerType H1

3P Price £ 4P Price £In (Aat 40°C) Icu (kAfor U = 220/415 V) - Ics = 100% Icu

NT06 630 42 47110 1155.17 47115 1581.63NT08 800 42 47120 1137.50 47125 1639.50NT10 1000 42 47130 1260.68 47135 1726.44NT12 1250 42 47140 1370.02 47145 1873.63NT16 1600 42 47150 1434.95 47155 1975.86

Type L13P Price £ 4P Price £

In (Aat 40°C) Icu (kAfor U = 220/415 V) - Ics = 100% IcuNT06 630 150 47112 1494.16 47117 1980.36NT08 800 150 47122 1548.58 47127 2052.81NT10 1000 150 47132 1619.22 47137 2153.47

Micrologic control unitAmmeter A

3P/4P Price £Micrologic 2.0 A Basic protection 47282 423.49Micrologic 5.0 A Selective protection 47285 579.09Micrologic 6.0 A Selective + earth-fault protection 47286 833.67Micrologic 7.0 A Selective + earth-leakage protection 47287 833.67

Power meter P3P/4P

Micrologic 5.0 P Selective protection 47289 1393.10Micrologic 6.0 P Selective + earth-fault protection 47290 1628.01Micrologic 7.0 P Selective + earth-leakage protection 47291 1628.01

Harmonic meter H3P/4P Price £

Micrologic 5.0 H Selective protection 47293 1940.50Micrologic 6.0 H Selective + earth-fault protection 47294 2171.04Micrologic 7.0 H Selective + earth-leakage protection 47295 2171.04

Communication optionModbus COM 47405 278.62Eco Modbus COM module 47407 191.21

A Masterpact fixedcircuit breaker isdescribed by 4catalogue numberscorresponding to:

■ The basic circuitbreaker

■ A control unit

■ A top connection

■ A bottomconnection

Communicationoption and variousauxiliaries andaccessories mayalso be added.

(1) Rectangular sensor required

(1)

(1)

(1)

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 12

NT06 to NT16Fixed circuit breakers

Circuit breaker selection

13

Front connection3P Price £ 4P Price £

630/1600A Top 47328 99.43 47330 131.12Bottom 47329 99.43 47331 131.12

Front connection accessoriesVertical connection adapters 630/1600A

3P (3 parts) 33642 97.254P (4 parts) 33643 130.05

Cable lug adapters 630/1600A3P (3 parts) 33644 87.084P (4 parts) 33645 115.35

Interphase barriers3P/4P top (3 parts) 33648 29.413P/4P bottom (3 parts) 33648 29.41

Arc chute screen3P 47335 15.604P 47336 23.41

Rear connectionVertical connection

630/1600A 3P Price £ 4P Price £Top 33604 95.00 33614 126.66Bottom 33605 95.00 33615 126.66

Horizontal connection630/1600A 3P Price £ 4P Price £

Top 33606 95.00 33616 126.66Bottom 33607 95.00 33617 126.66

Rear connection accessoriesInterphase barriers3P/4P top (3 parts) 33648 29.413P/4P bottom (3 parts) 33648 29.41

Common accessories for front and rear connectionsSpreader

630/1600A 3P 33622 97.254P 33623 126.66

For front and horizontal rear connection

Cable lug kits240mm2 3P (6 lug kit) 33013 82.55

4P (8 lug kit) 33014 113.08300mm2 3P (6 lug kit) 33015 89.33

4P (8 lug kit) 33016 118.74

MGLV5705 MASTERPACT (V3) 19/2/05 12:20 pm Page 13

14

NT06 to NT16Fixed circuit breakersIndication contacts

M2C

M6C

* For Micrologic control units P and H only.

Indication contacts (OF)Changeover contacts (6A - 240V) 4 (standard) Price £1 low-level OF to replace 1 standard OF (4 max.) 47339 22.95

"Fault trip" indication contacts (SDE)Changeover contact (5A - 240V) 1 (standard)1 additional SDE (5A - 240V) 47340 27.411 additional low-level SDE 47341 32.77

Programmable contacts* (programmed via Micrologic control unit)2 contacts (M2C) (5A - 240V) 47403 59.44

6 changeover contacts (M6C) (5A - 240V) 47404 164.49

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 14

Remote ON/OFFGear motor

MCH Price £AC 50/60 Hz 48 V 47391 437.05

100-130 V 47395 437.05200-240 V 47396 437.05277-415 V 47398 437.05440-480V 47400 437.05

DC 24-30 V 47390 437.0548-60 V 47391 437.05100-130 V 47392 437.05200-250 V 47393 437.05

Instantaneous voltage releasesClosing release Opening release

Standard XF Price £ MX Price £AC 50/60 Hz 12 V DC 47349 75.40 47359 75.40DC 24-30 V DC, 24 V AC 47350 75.40 47360 75.40

48-60 V DC, 48 V AC 47351 75.40 47361 75.40100-130 V 47352 75.40 47362 75.40200-250 V 47353 75.40 47363 75.40277 V AC 47354 75.40 47364 75.40380-480 V AC 47355 75.40 47365 75.40

Communicating XF com Price £ MX com Price £AC 50/60 Hz 12 V DC 47310 91.39 47320 91.39DC 24-30 V DC, 24 V AC 47311 91.39 47321 91.39

48-60 V DC, 48 V AC 47312 91.39 47322 91.39100-130 V 47313 91.39 47323 91.39200-250 V 47314 91.39 47324 91.39277 V AC 47315 91.39 47325 91.39380-480 V AC 47316 91.39 47326 91.39

Ready to close contact (1 max.)PF Price £

1 changeover contact (5 A - 240 V) 47342 111.951 low-level changeover contact 47343 134.80

Electrical closing pushbuttonBPFE Price £

1 pushbutton 47512 91.39

Remote reset after fault tripElectrical reset Res Price £110-130 V AC 47344 91.39220-240 V AC 47345 91.39Automatic reset RARAdaptation 47346 *

Remote trippingInstantaneous voltage release

2nd MX Price £ or MN Price £AC 50/60 Hz 12 V DC 47369 75.40DC 24-30 V DC, 24 V AC 47370 75.40 47380 125.66

48-60 V DC, 48 V AC 47371 75.40 47381 125.66100-130 V 47372 75.40 47382 125.66200-250 V 47373 75.40 47383 125.66277 V AC 47374 75.40380-480 V AC 47375 75.40 47385 125.66

MN delay unitR (non-adjustable) Rr (adjustable)

AC 50/60 Hz 48-60 V 33680 186.59DC 100-130 V 33684 150.67 33681 186.59

200-250 V 33685 150.67 33682 186.59380-480 V 33683 186.59

* No charge.

15

NT06 to NT16Fixed circuit breakers

Remote operation

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 15

16

NT06 to NT16Drawout circuit breakersCircuit breaker selection

Basic circuit breakerType H1

3P Price £ 4P Price £In (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% Icu

NT06 630 42 47200 733.38 47205 1153.90NT08 800 42 47210 797.64 47215 1236.51NT10 1000 42 47220 867.00 47225 1320.01NT12 1250 42 47230 1013.88 47235 1483.47NT16 1600 42 47240 1208.70 47245 1897.20

Type L13P Price £ 4P Price £

In (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% IcuNT06 630 150 47202 1242.86 47207 1777.62NT08 800 150 47212 1333.21 47217 1894.23NT10 1000 150 47222 1423.56 47227 2007.70

Micrologic control unitAmmeter A

3P/4P Price £Micrologic 2.0 A Basic protection 33525 429.73Micrologic 5.0 A Selective protection 33532 587.60Micrologic 6.0 A Selective + earth-fault protection 33533 845.93Micrologic 7.0 A Selective + earth-leakage protection 33534 845.93

Power meter P3P/4P Price £

Micrologic 5.0 P Selective protection 47297 1393.10Micrologic 6.0 P Selective + earth-fault protection 47298 1628.01Micrologic 7.0 P Selective + earth-leakage protection 47299 1628.01

Harmonic meter H3P/4P Price £

Micrologic 5.0 H Selective protection 47301 1940.50Micrologic 6.0 H Selective + earth-fault protection 47302 2171.04Micrologic 7.0 H Selective + earth-leakage protection 47303 2171.04

ChassisFor type H1

3P Price £ 4P Price £630/1250 A 33722 916.66 33725 994.951600 A 33723 932.80 33726 1030.88

For type L13P Price £ 4P Price £

630/100 A 33723 932.80 33726 1030.88

Communication optionChassis + Circuit breaker

Modbus COM 33852 110.83 47485 278.62Eco Modbus COM module 33843 194.02

A Masterpactdrawout circuitbreaker is describedby 5 cataloguenumberscorresponding to:

■ The basic circuitbreaker

■ A control unit

■ A chassis

■ A top connection

■ A bottomconnection

A communicationoption and variousauxiliaries andaccessories mayalso be added.

(1) Rectangular sensor required

(1)

(1)

(1)

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 16

17

NT06 to NT16Drawout circuit breakers

Circuit breaker selection

Chassis front connection3P Price £ 4P Price £

630/1600A Top 33727 67.86 33733 90.46Bottom 33728 67.86 33734 90.46

Front connection accessoriesVertical connection adapters 630/1600A

3P (3 parts) 33642 97.254P (4 parts) 33643 130.05

Cable lug adapters 630/1600A3P (3 parts) 33644 87.084P (4 parts) 33645 115.35

Chassis rear connectionVertical connection

3P Price £ 4P Price £630/1600A Top 33729 67.86 33735 90.46

Bottom 33730 67.86 33736 90.46

Horizontal connection3P Price £ 4P Price £

630/1600A Top 33731 67.86 33737 90.46Bottom 33732 67.86 33738 90.46

Rear connection accessoriesInterphase barriers

3P/4P (3 parts) 33768 29.41

Common accessories for front and rear connectionSpreaders

630/1600A 3P 33622 97.254P 33623 126.66

For front and horizontal rear connection.

Cable lug kits

240mm2 3P (6 lug kit) 33013 82.554P (8 lug kit) 33014 113.08

300mm2 3P (6 lug kit) 33015 89.334P (8 lug kit) 33016 118.74

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 17

18

NT06 to NT16Drawout circuit breakersChassis locking and accessories

(*) No charge

Chassis lockingDisconnected position locking

By padlocks

By keylocks Standard Price £Profalux 1 lock 33773 47.49

1 lock + 1 lock with same key profile 33774 95.002 locks (different key profiles) 33775 95.00

Ronis 1 lock 33776 47.491 lock + 1 lock with same key profile 33777 95.002 locks (different key profiles) 33778 95.00

Optional disconnected/test/connected position locking 33779 *Locking kit without locks for Profalux 33769 24.88

Ronis 33770 24.88Castell 33771 92.73Kirk 33772 94.23

Door interlock (1 part)Right-hand side of chassis (VPECD) 33786 31.66Left-hand side of chassis (VPECG) 33787 31.66

Racking interlockRacking interlock (VPOC) 33788 35.05

Breaker mismatch protectionBreaker mismatch protection (VDC) 33767 50.89

Chassis accessoriesArc chute cover 3P/4P Standard

Auxiliary terminal shield (CB)Terminal shield 3P 33763 31.66

4P 33764 36.19

Safety shuttersSafety shutters (VO) 3P 33765 52.03

4P 33766 62.19

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 18

19

NT06 to NT16Drawout circuit breakers

Indication contacts

M2C

M6C

ON/OFF indication contacts (OF)Changeover contacts (6A - 240V) 4 (standard) Price £1 low-level OF to replace 1 standard OF (4 max.) 33806 32.80

Fault trip indication contacts (SDE)Changeover contact (5A - 240V) 1 (standard) Price £1 additional SDE (5A - 240V) 47430 26.751 additional low-level SDE 47431 32.32

Programmable contacts * (programmed via Micrologic control unit)2 contacts M2C (5A - 240V) 47483 60.55

6 changeover contacts M6C (5A - 240V) 47484 164.49

Carriage switches (connected / disconnected / test position)Changeover contacts (6A - 240 V)1 connected position contact (3 max.) 33751 27.811 test position contact (1 max.) 33752 27.811 disconnected position contact (2 max.) 33753 25.50And/or low-level changeover contacts1 connected position contact (3 max.) 33754 33.611 test position contact (1 max.) 33755 33.611 disconnected position contact (2 max.) 33756 33.61

Auxiliary terminals for chassis alone3 wire terminal (30 parts) 47071 109.226 wire terminal (10 parts) 47072 105.88Jumpers (10 parts) 47900 11.14

(*) For Micrologic control units P and H only.

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 19

20

NT06 to NT16Drawout circuit breakersRemote operation

Remote ON/OFFGear motor

MCH Price £AC 50/60 Hz 48 V 47461 437.05

100-130 V 47465 437.05200-240 V 47466 437.05277-415 V 47468 437.05440-480 V 47470 437.05

DC 24-30 V 47460 437.0548-60 V 47461 437.05100-130 V 47462 437.05200-250 V 47463 437.05

Instantaneous voltage releaseClosing release Opening release

Standard XF Price £ MX Price £AC 50/60 Hz 12 V DC 47439 73.55 33809 74.63DC 24-30 V DC, 24 V AC 47440 73.55 33810 74.63

48-60 V DC, 48 V AC 47441 73.55 33811 74.63100-130 V 47442 73.55 33812 74.63200-250 V 47443 73.55 33813 74.63277 V AC 47444 73.55 33814 74.63380-480 V AC 47445 73.55 33815 74.63

Communicating XF com MX comAC 50/60 Hz 12 V DC 47411 91.39 33791 92.73DC 24-30 V DC, 24 V AC 47412 91.39 33792 92.73

48-60 V DC, 48 V AC 47413 91.39 33793 92.73100-130 V 47414 91.39 33794 92.73200-250 V 47415 91.39 33795 92.73277 V AC 47416 91.39 33796 92.73380-480 V AC 47417 91.39 33797 92.73

Ready to close contact (1 max.) PF Price £

1 changeover contact (5 A - 240 V) 47432 111.951 low-level changeover contact 47433 134.80

Electrical closing pushbuttonBPFE Price £

1 pushbutton 47512 91.39

Remote reset after fault tripElectrical reset Res Price £110-130 V AC 47434 99.38220-240 V AC 47435 99.38Automatic reset RARAdaptation 47346 *

Remote trippingInstantaneous voltage release

2nd MX Price £ or MN Price £AC 50/60 Hz 12 V DC 47449 73.55DC 24-30 V DC, 24 V AC 47450 73.55 33819 124.39

48-60 V DC, 48 V AC 47451 73.55 33820 124.39100-130 V 47452 73.55 33821 124.39200-250 V 47453 73.55 33822 124.39277 V AC 47454 73.55380-480 V AC 47455 73.55 33824 124.39

MN delay unitR (non-adjustable) Rr (adjustable)

AC 50/60 Hz 48-60 V 33680 186.59DC 100-130 V 33684 150.67 33681 186.59

200-250 V 33685 150.67 33682 186.59380-480 V 33683 186.59

(*) No charge.

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 20

21

Accessories NT06 to NT16Fixed or drawout circuit breakers

Circuit breaker selection

Escutcheon Cover Blanking plate

(*) Can be used with any combination of NT or NW, fixed or drawout devices.

Circuit breaker lockingPushbutton locking device

Price £By padlocks 33897 29.41

OFF position lockingBy padlocks + BPFE support

47514 32.29By keylocks + BPFE supportProfalux 1 lock 47519 47.49

1 lock + 1 lock with same key profile 47520 95.00Ronis 1 lock 47521 47.49

1 lock + 1 lock with same key profile 47522 95.00Locking kit without locks for Profalux 47515 24.04

Ronis 47516 24.04Kirk 47517 94.73Castell 47518 91.39

Other circuit breaker accessoriesMechanical operation counter

Operation counter CDM 33895 85.94

Escutcheon and accessoriesFixed Price £ Drawout Price £

Escutcheon 33718 18.09 33857 36.19Transparent cover (IP54) 33859 176.41Escutcheon blanking plate 33858 56.55

Mechanical interlocking for source changeoverInterlocking using connecting rods

Complete assembly with 2 adaptation fixtures + rods2 Masterpact NT fixed devices 33912 491.932 Masterpact NT drawout devices 33913 491.93

Interlocking using cables *Choose 2 adaptation fixtures (1 for each breaker) + 1 set of cables1 adaptation fixture for Masterpact NT fixed devices 33200 156.961 adaptation fixture for Masterpact NT drawout devices 33201 156.961 set of 2 cables 33209 86.94

Cable-type door interlock1 complete assembly for Masterpact NT fixed devices 33920 382.421 complete assembly for Masterpact NT drawout devices 33921 382.42

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 21

22

NT06 to NT16Fixed or drawout circuit breakersCircuit breaker selection

L3

G1

AD 220A

L4

G2

Input

24VDC

Output

24VDC

Special settingsFor circuit breaker deratingCatalogue number to be added to those describing the circuit breaker ratingRating NT06 NT08 NT10 NT12 NT16400 47053 47053 47053630 33091 33091 33091800 33092 33092 330921000 33093 330931250 33094Note: for ratings In = 100 or 250A, please contact Merlin Gerin.

Accessories for Micrologic control unitsExternal sensorsExternal sensor for earth-leakage protection (TCE) Price £

Sensor rating 400/1600 A (for Micrologic P and H with 3P devices) 33576 305.33

Rectangular sensor for earth-leakage protection280 mm x 115mm 33573 780.30

Source ground return (SGR) earth fault protectionExternal sensor (SGR) 33579 371.06MDGF summing module 48891 468.08

Voltage measurement input (for breakers supplied via bottom terminals)Voltage measurement input Fixed 47506 17.46

Drawout 47507 17.46

Long-time rating plug (limits setting range for higher accuracy)Standard 0.4 to 1 x Ir 33542 28.27Low-setting option 0.4 to 0.8 x Ir 33543 28.27High-setting option 0.8 to 1 x Ir 33544 28.27Without long-time protection Off 33545 28.27

Zone Selective Interlocking option for Micrologic P and HZSI Standard

External power supply module24-30 V DC 54440 253.3248-60 V DC 54441 253.32125 V DC 54442 253.32110 V AC 54443 253.32220 V AC 54444 253.32380 V AC 54445 253.32

Batter module1 24 V battery 54446 248.80

Test equipmentMini test kit 33594 551.75

Portable test kit 33595 3680.27Replacement test leads 33590 124.39

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 22

23

NT06 to NT16Fixed switch disconnectors

Switch disconnector selection

A Masterpact fixedswitch disconnectoris described by 3catalogue numberscorresponding to:

■ The basic switchdisconnector

■ A top connection

■ A bottomconnection

A communicationoption and variousauxiliaries andaccessories mayalso be added.

Basic switch disconnectorType HA

3P Price £ 4P Price £In (Aat 40°C) Icm (kApeak for U = 220/690 V)

NT06 630 60 47159 1369.78 47160 1746.93NT08 800 60 47161 1420.00 47162 1851.03NT10 1000 60 47163 1490.27 47164 1944.03NT12 1250 60 47165 1610.86 47166 2101.20NT16 1600 60 47167 1688.11 47168 2214.70Communication optionModbus COM 47405 278.62

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 23

24

NT06 to NT16Fixed switch disconnectorsConnection terminals and accessories

Front connection3P Price £ 4P Price £

630/1600A Top 47328 99.43 47330 131.12Bottom 47329 99.43 47331 131.12

Front connection accessoriesVertical connection adapters 630/1600 A

3P (3 parts) 33642 97.254P (4 parts) 33643 130.05

Cable lug adapters 630/1600 A3P (3 parts) 33644 87.084P (4 parts) 33645 115.35

Interphase barriers3P/4P top (3 parts) 33648 29.413P/4P bottom (3 parts) 33648 29.41

Rear connectionVertical connection

3P Price £ 4P Price £630/1600 A Top 33604 95.00 33614 126.66

Bottom 33605 95.00 33615 126.66

Horizontal connection3P Price £ 4P Price £

630/1600 A Top 33606 95.00 33616 126.66Bottom 33607 95.00 33617 126.66

Rear connection accessoriesInterphase barriers

3P/4P top (3 parts) 33648 29.413P/4P bottom (3 parts) 33648 29.41

Common accessories for front and rear connectionSpreaders

630/1600 A 3P 33622 97.254P 33623 126.66

For front and horizontal rear connection

Cable lug kits240mm2 3P (6 lug kit) 33013 82.55

4P (8 lug kit) 33014 113.08300mm2 3P (6 lug kit) 33015 89.33

4P (8 lug kit) 33016 118.74

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 24

25

NT06 to NT16Drawout switch disconnectors

Switch disconnector selection

A Masterpactdrawout switchdisconnector isdescribed by 4catalogue numberscorresponding to:

■ The basic switchdisconnector

■ A chassis

■ A top connection

■ A bottomconnection

A communicationoption and variousauxiliaries andaccessories mayalso be added.

MERLIN GERIN

Basic switch disconnectorType HA

3P Price £ 4P Price £In (Aat 40°C) Icm (kApeak for U = 220/690 V)

NT06 630 60 47248 938.19 47249 1343.72NT08 800 60 47250 1008.58 47251 1345.82NT10 1000 60 47252 1087.37 47253 1526.52NT12 1250 60 47254 1246.01 47255 1699.87NT16 1600 60 47256 1443.52 47257 2047.62

Chassis3P Price £ 4P Price £

630/1250 A 33722 916.66 33725 994.951600 A 33723 932.80 33726 1030.88

Communication optionChassis + Switch disconnector

COM Modbus 33852 110.83 47485 278.62

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 25

26

NT06 to NT16Drawout switch disconnectorsSwitch disconnector selection

Chassis front connection3P Price £ 4P Price £

630/1600A Top 33727 67.86 33733 90.46Bottom 33728 67.86 33734 90.46

Front connection accessoriesVertical connection adapters 630/1600 A

3P (3 parts) 33642 97.254P (4 parts) 33643 130.05

Cable lug adapters 630/1600 A3P (3 parts) 33644 87.084P (4 parts) 33645 115.35

Chassis rear connectionVertical connection

3P Price £ 4P Price £630/1600A Top 33729 67.86 33735 90.46

Bottom 33730 67.86 33736 90.46

Horizontal connection3P Price £ 4P Price £

630/1600A Top 33731 67.86 33737 90.46Bottom 33732 67.86 33738 90.46

Rear connection accessoriesInterphase barriers

3P/4P (3 parts) 33768 29.41

Common accessories for front and rear connectionSpreaders

630/1600 A 3P 33622 97.254P 33623 126.66

For front and horizontal rear connection

Cable lug kits240mm2 3P (6 lug kit) 33013 82.55

4P (8 lug kit) 33014 113.08300mm2 3P (6 lug kit) 33015 89.33

4P (8 lug kit) 33016 118.74

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 26

27

Communication bus accessories and display modules

RS485 Modbus pre-wired systemRS485 Modbus junction block

Price £CJB306: 6 SubD 9 pins connectors junction block 50963 65.59

RS485 Modbus connectorCSD309: 9 pins SubD with screw terminals 50964 27.72

RS485 Modbus cablesCDM303: display module pre-wired cable, 3 m length 50960 33.26

CCP303: Masterpact or Compact pre-wired cable 50961 24.88(4 RS485 wires + 2 power wires) 3 m length

CCR301: RS485 roll cable 50965 255.32(2 RS485 wires + 2 power wires) 60 m length

Micropower server with automatic notificationMicropower Server MPS100 33507 788.0224vDC power supply PS080 232.46

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 27

NT06 to NT16Circuit breakers and switch disconnectorsOrder form

To indicate your choices, check the applicablesquare boxes ■■ and enter the appropriateinformation in the rectangles

Basic device Quantity

Masterpact type NTRated current ASensor rating ACircuit breaker H1, L1Switch disconnector HANumber of poles 3 or 4Option: Neutral on right hand side ■■

Type of device Fixed ■■

Draw out with chassis ■■

Draw out without chassis ■■

Chassis alone ■■

Locking

VBP - ON/OFF pushbutton locking ■■

Off position lockingLocking kit ■■ Profalux ■■ Ronis ■■withoutkeylocks1 lock ■■ 1 lock + 1 lock

with same key profile ■■

VSPD - chassis locking Locking kit ■■ Profalux ■■ Ronis ■■in disconnected position without

keylocks1 lock ■■ 1 lock + 1 lock

with same key profile ■■

2 locks (differrent profiles) ■■

VPEC - door interlock Latch on right hand side of chassis ■■

Latch on left hand side of chassis ■■

VPOC - Racking interlock ■■

IPA - Cable type door interlock ■■

VDC - Mismatch protection ■■

Indication contacts

ON/OFF indication contactsStandard 4 of 6A - 240V AC (10A - 240V AC low level)Alternate 1 of low level for NT Max. 4 Qty(Replaces a standard contact)SDE - fault trip indication contactsStandard 1 SDE 5A - 240V AC ■■

Additional 1 SDE 5A - 240V AC ■■

1 SDE low level ■■

Programmable contacts 2 M2C contacts ■■

6 M6C contacts ■■

Carriage switches Low level ■■

6A - 240V AC ■■

CE - connected position Max. 3 Qty CD - disconnected position Max. 2 Qty CT - test position Max. 1 Qty AC - Actuator for additional carriage switches Qty

Micrologic control unit

A - ammeter2.0 ■■ 5.0 ■■ 6.0 ■■ 7.0 ■■

P - power meter5.0 ■■ 6.0 ■■ 7.0 ■■

H - harmonic meter5.0 ■■ 6.0 ■■ 7.0 ■■

TCE - external sensor (CT) for neutral + earth fault protection ■■

Rectangular sensor 280 X 115 ■■

LT - long time rating plug (standard setting 0.4 to 1 x Ir)

Low setting option 0.4 to 0.8 Ir■■High setting option 0.8 to 1 Ir ■■

LT OFF option ■■

PTE - external voltage measurement input ■■

AD - external power supply module ■■

BAT - battery module ■■

Communication

COM Modbus ■■

Eco COM Modbus ■■

Connection

Horizontal Top ■■ Bottom ■■Vertical Top ■■ Bottom ■■Front Top ■■ Bottom ■■Bare cable connectors NT-FC, fixed, draw ■■

4 x 20 mm2 + connector shieldVertical connection adapters NT-FC, fixed, draw ■■

Cable lug adapters NT-FC, fixed, draw ■■

Interphase barriers NT, fixed, draw ■■

Spreaders NT, fixed, drawout ■■

Key for Micrologic control units

2.0: Basic protection (long time + inst.)

5.0: Selective protection (long time + short time + inst.)

6.0: Selective + earth fault protection (long time + short time + inst. + earth fault)

7.0: Selective + earth leakage protection (long time + short time + inst. + earth leakage)

Remote operation

Remote ON/OFF MCH - Gear motor VXF - Closing voltage release V MX - Opening voltage release VPF - Ready to close contact Low level ■■

6A - 240V AC ■■BPFE - Electrical closing pushbutton ■■

Res - Electrical reset option ■■

RAR - Automatic reset option ■■

Remote tripping MN - Undervoltage release VR - Delay unit (non-adjustable) ■■

Rr - Adjustable delay unit ■■

2nd MX - Shunt release V

Accessories

CDM - Mechanical operation counter ■■

CB - Auxiliary terminal shield for chassis ■■

CDP - Escutcheon ■■

CP - Transparent cover ■■

OP - Blanking plate ■■

Brackets for mounting on backplates ■■

Please photocopy and complete this form and

fax it to 0870 608 8 606

Sheet of

28

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 28

29

Section 2 Masterpact NW

Standard specifications

Prices shown for circuit breakers and switch disconnectors include:

Fixed

■ 4 changeover auxiliary contacts.

■ Door escutcheon.

Drawout

■ 4 changeover auxiliary contacts.

■ Busbar shutters (padlockable).

■ Arc chute cover.

■ Auxiliary terminal shield.

■ Mismatch protection.

■ Door interlock.

■ Door escutcheon.

■ Racking handle.

All circuit and switch disconnectors are complete with:

■ Manual open/close pushbuttons.

■ Hand charged stored energy operating mechanism.

NW

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 29

30

NW08 to NW63fixed circuit breakersCircuit breaker selection

The specification of a fixed Masterpactcircuit breaker requires 4 catalougenumbers, corresponding to:1 The basic circuit breaker.2 A control unit.3 A top connection.4 A bottom connection.A communication option and variousauxiliaries and accessories may also beadded.

Auxiliaries and accessories:■ For fixed devices: see page 32-33.■ For fixed or drawout devices: see page 40-41.Switch disconnector version: see page 42-43.Interlocking: see page 40.

(1) Rectangular sensor required, see page 41.

Basic switch disconnector ≤ 4000 A

Basic switch disconnector > 4000b A

1 Basic circuit breakerType H1

3P Price £ 4P Price £In (A at 40°C)Icu (kA for U = 220/440 V) - Ics = 100% Icu

NW08 800 65 48001 1451.00 48008 1987.12NW10 1000 65 48015 1492.52 48022 2043.95NW12 1250 65 48029 1567.92 48036 2144.25NW16 1600 65 48043 1642.21 48050 2261.27NW20 2000 65 48057 2422.34 48064 3103.82NW25 2500 65 48070 2844.10 48076 3939.68NW32 3200 65 48082 3913.78 48087 5224.66NW40 4000 65 48092 5870.67 48097 7519.37NW40b 4000 100 48106 6961.55 48109 8896.58NW50 5000 100 48112 11452.51 48115 12689.11NW63 6300 100 48118 14944.47 48121 17324.70Type H2

3P Price £ 4P Price £In (A at 40°C)Icu (kA for U = 220/440 V) - Ics = 100% Icu

NW08 800 100 48002 1822.17 48009 2415.07NW10 1000 100 48016 1861.18 48023 2475.25NW12 1250 100 48030 1941.42 48037 2549.92NW16 1600 100 48044 2051.75 48051 2767.25NW20 2000 100 48058 2966.74 48065 3769.16NW25 2500 100 48071 3914.04 48077 4927.11NW32 3200 100 48083 4990.63 48088 6601.04NW40 4000 100 48093 7334.36 48098 9653.59NW40b 4000 150 48107 8905.68 48110 11690.70NW50 5000 150 48113 14543.12 48116 15412.44NW63 6300 150 48119 18610.99 48122 20586.08OptionNeutral on the right (1)

(1)

(1)

(1)

2 Micrologic control unit"Ammeter" A

3P/4P Price £Micrologic 2.0A basic protection 47282 423.49Micrologic 5.0 A selective protection 47285 579.09Micrologic 6.0 A selective + earth-fault protection 47286 833.67Micrologic 7.0 A selective + earth-leakage protection 47287 833.67Power meter P

3P/4PMicrologic 5.0 P selective protection 47289 1393.10Micrologic 6.0 P selective + earth-fault protection 47290 1628.01Micrologic 7.0 P selective + earth-leakage protection 47291 1628.01“Harmonic meter” H

3P/4PMicrologic 5.0H selective protection 47293 1940.50Micrologic 6.0H selective + earth-fault protection 47294 2171.04Micrologic 7.0H selective + earth-leakage protection 47295 2171.04

Communication optionModbus COM 48188 278.62

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 30

31

NW08 to NW63fixed circuit breakers (cont.)

Circuit breaker selection (cont.)

3 and 4 Rear connectionHorizontal connection

3P Price £ 4P Price £800/2000 A Top 48143 40.12 48168 54.83

Bottom 48148 40.12 48173 54.832500/3200 A Top 48144 77.67 48169 102.88

Bottom 48149 77.67 48174 102.884000 A Top 48145 143.98 48170 191.91

Bottom 48150 143.98 48175 191.914000b/5000 A Top 48146 150.79 48171 201.06

Bottom 48151 150.79 48176 201.06Vertical connection

3P Price £ 4P Price £800/2000 A Top 48133 40.12 48158 54.83

Bottom 48138 40.12 48163 54.832500/3200 A Top 48134 77.67 48159 102.88

Bottom 48139 77.67 48164 102.884000 A Top 48135 143.98 48160 191.91

Bottom 48140 143.98 48165 191.914000b/5000 A Top 48136 150.79 48161 201.06

Bottom 48141 150.79 48166 201.066300 A Top 48137 287.87 48162 383.83

Bottom 48142 287.87 48167 383.83Rear connection accessoriesInterphase barriers

3P/4P (3 parts) 48599 70.82

Brackets for mounting on a backplate2 parts 47829 85.69

3 and 4 Front connection3P 4P

800/1600 A Top 48128 226.24 48153 301.57Bottom 48130 226.24 48155 301.57

2000 A Top 48124 281.07 48126 374.68Bottom 48125 281.07 48127 374.68

2500/3200 A Top 48129 596.35 48154 795.08Bottom 48131 596.35 48156 795.08

Front connection accessoriesDisconnectable front connection

3P 4P1600 A 48421 108.53 48424 145.082000/3200 A 48422 148.52 48425 197.64

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 31

32

M6C

NW08 to NW63fixed circuit breakers (cont.)Indication contacts

M2C

ON/OFF indication contacts (OF)Block of 4 changeover contacts (6 A - 240 V) 1 block (standard) Price £1 additional block of 4 contacts (2 max.) 48198 99.38

Fault trip indication contacts (SDE)Changeover contact (5 A - 240 V) 1 (standard)1 additional SDE (5 A - 240 V) 48200 27.411 additional low-level SDE 48201 33.12

Programmable contacts (*) (programmed via Micrologic control unit)2 contacts M2C (5 A - 240 V) 47403 59.446 changeover contacts M6C (5 A - 240 V) 47404 164.49(*) for Micrologic P control units only.

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 32

33

NW08 to NW63fixed circuit breakers (cont.)

Remote operation

Remote ON/OFFGear motor

MCH Price £AC 50/60 Hz 48 V 48207 456.94

100-130 V 48211 456.94200-240 V 48212 456.94250-277 V 48213 456.94380-415 V 48214 456.94440-480 V 48215 456.94

DC 24-30 V 48206 456.9448-60 V 48207 456.94100-130 V 48208 456.94200-250 V 48209 456.94

Instantaneous voltage releasesClosing release Opening release

Standard XF Price £ MX Price £AC 50/60 Hz 12 V DC 47349 75.40 47359 75.40DC 24-30 V DC, 24 V AC 47350 75.40 47360 75.40

48/60 V DC, 48 V AC 47351 75.40 47361 75.40100-130 V 47352 75.40 47362 75.40200-250 V 47353 75.40 47363 75.40277 V AC 47354 75.40 47364 75.40380-480 V AC 47355 75.40 47365 75.40

Communicating XF com Price £ MX com Price £AC 50/60 Hz 12 V DC 47310 91.39 47320 91.39DC 24-30 V DC, 24 V AC 47311 91.39 47321 91.39

48-60 V DC, 48 V AC 47312 91.39 47322 91.39100-130 V 47313 91.39 47323 91.39200-250 V 47314 91.39 47324 91.39277 V AC 47315 91.39 47325 91.39380-480 V AC 47316 91.39 47326 91.39

"Ready to close" contact (1 max.)PF

1 changeover contact (5 A - 240 V) 47342 111.951 low-level changeover contact 47343 134.80

Electrical closing pushbuttonBPFE Price £

1 pushbutton 48534 85.69

Remote reset after fault tripElectrical reset Res Price £110-130 V AC 48202 99.38220-240 V AC 48203 99.38Automatic reset RARAdaptation 47346 (*)

Remote trippingInstantaneous voltage release

2nd MX Price £ or MN Price £AC 50/60 Hz 12 V DC 47369 75.40DC 24-30 V DC, 24 V AC 47370 75.40 47380 125.66

48-60 V DC, 48 V AC 47371 75.40 47381 125.66100-130 V 47372 75.40 47382 125.66200-250 V 47373 75.40 47383 125.66277 V AC 47374 75.40380-480 V AC 47375 75.40 47385 125.66

MN delay unitR (non-adjustable) Rr (adjustable)

AC 50/60 Hz 48-60 V 33680 186.59DC 100-130 V 33684 150.67 33681 186.59

200-250 V 33685 150.67 33682 186.59380-480 V 33683 186.59

(*) No charge

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 33

34

NW08 to NW63drawout circuit breakersCircuit breaker selection

The specification of a drawoutMasterpact circuit breaker requires 5catalouge numbers, corresponding to:1 The basic circuit breaker.2 A control unit.3 A chassis.4 A top connection.5 A bottom connection.A communication option and variousauxiliaries and accessories may also beadded.

Basic circuit breaker + chassis ≤ 4000 A

Basic circuit breaker + chassis ≤ 4000b A

1 Basic circuit breaker3P 4P

Type H1In (Aat 40°C)Icu (kAfor U = 220/440 V) - Ics = 100% Icu

NW08 800 65 48231 1581.03 48238 2111.93NW10 1000 65 48245 1612.71 48252 2145.37NW12 1250 65 48259 1706.68 48266 2235.64NW16 1600 65 48273 1947.06 48280 2749.41NW20 2000 65 48287 2633.23 48294 3531.78NW25 2500 65 48300 3366.37 48306 4543.72NW32 3200 65 48312 4940.85 48317 6334.69NW40 4000 65 48322 7233.18 48327 9389.46NW40b 4000 100 48336 7777.99 48339 10127.97NW50 5000 100 48342 11060.53 48345 14136.47NW63 6300 100 48348 16487.75 48351 18831.45Type H2

In (Aat 40°C)Icu (kAfor U = 220/440 V) - Ics = 100% IcuNW08 800 100 48232 1953.67 48239 2539.89NW10 1000 100 48246 1983.76 48253 2576.67NW12 1250 100 48260 2082.96 48267 2640.20NW16 1600 100 48274 2362.70 48281 3255.39NW20 2000 100 48288 3189.48 48295 4197.12NW25 2500 100 48301 4475.73 48307 5564.58NW32 3200 100 48313 6086.16 48318 7766.79NW40 4000 100 48323 8724.12 48328 11523.68NW40b 4000 150 48337 9804.69 48340 13007.81NW50 5000 150 48343 14179.86 48346 18294.56NW63 6300 150 48349 20229.67 48352 22377.28Type H3

In (Aat 40°C)Icu (kAfor U = 220/440 V) - Ics = 100% IcuNW20 2000 150 48289 3818.20 48296 5036.33NW25 2500 150 48302 5370.67 48308 6677.94NW32 3200 150 48314 7303.16 48319 9320.37NW40 4000 150 48324 10472.74 48329 13828.43Type L1

In (Aat 40°C)Icu (kAfor U = 220/440 V) - Ics = 100% IcuNW08 800 150 48233 2246.78 48240 2921.05NW10 1000 150 48247 2281.34 48254 2963.39NW12 1250 150 48261 2396.12 48268 3091.56NW16 1600 150 48275 2717.09 48282 3743.52NW20 2000 150 48290 3658.83 48297 4826.80OptionNeutral on the right (1)2 Micrologic control unit"Ammeter" A

3P/4P Price £Micrologic 2.0A basic protection 48358 423.39Micrologic 5.0 A selective protection 48360 579.09Micrologic 6.0 A selective + earth-fault protection 48361 833.67Micrologic 7.0 A selective + earth-leakage protection 48362 833.67"Power meter" P

3P/4PMicrologic 5.0 P selective protection 48363 1393.10Micrologic 6.0 P selective + earth-fault protection 48364 1628.01Micrologic 7.0 P selective + earth-leakage protection 48365 1628.01"Harmonic meter" H

3P/4PMicrologic 5.0 H selective protection 47293 1940.50Micrologic 6.0 H selective + earth-fault protection 47294 2171.04Micrologic 7.0 H selective + earth-leakage protection 47295 2171.04

(1) Rectangular sensor required, see page 41

(1)

(1)

(1)

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 34

35

NW08 to NW63drawout circuit breakers (cont.)

Circuit breaker selection (cont.)

Auxiliaries and accessories:■ For drawout devices: see page 38-39■ For fixed or drawout devices: see page 40-41Switch disconnector version: see page 42-43Interlocking: see page 40

Chassis ≤ 4000 A

3 Chassis3P Price £ 4P Price £

For type H1/H2800/1600 A 48392 525.48 48404 639.712000 A 48393 643.13 48405 799.632500 A 48394 643.13 48406 799.633200 A 48395 879.66 48407 1113.784000 A 48396 939.01 48408 1197.174000b/6300 A 48397 1872.29 48409 2333.80For type H32000/2500 A 48394 643.13 48406 799.633200 A 48395 879.66 48407 1113.784000 A 48396 939.01 48408 1197.17For type L1800/1600 A 48399 684.27 48411 851.052000 A 48400 981.27 48412 1244.00Communication option

Chassis Circuit breakerModbus COM 33852 110.83 48384 278.62

4 and 5 Chassis rear connection3P Price £ 4P Price £

Vertical connection800/2000 A Top 48133 40.12 48158 54.83800/1600 A type L1 Bottom 48138 40.12 48163 54.832500/3200 A Top 48134 77.67 48159 102.882000 Atypes H3/L1 Bottom 48139 77.67 48164 102.884000 A Top 48135 143.98 48160 191.91

Bottom 48140 143.98 48165 191.914000b/5000 A Top 48136 150.79 48161 201.06

Bottom 48141 150.79 48166 201.066300 A Top 48137 287.87 48162 383.83

Bottom 48142 287.87 48167 383.83Horizontal connection

800/2000 A Top 48143 40.12 48168 54.83800/1600 Atype L1 Bottom 48148 40.12 48173 54.832500/3200 A Top 48144 77.67 48169 102.882000 Atypes H3/L1 Bottom 48149 77.67 48174 102.884000 A Top 48145 143.98 48170 191.91

Bottom 48150 143.98 48175 191.914000b/5000 A Top 48146 150.79 48171 201.06

Bottom 48151 150.79 48176 201.06Rear connection accessories

Interphase barriers3P/4P (3 parts) 48600 68.54

4 and 5 Chassis front connection3P 4P

800/1600 A Top 48415 226.19 48441 301.57Bottom 48418 226.19 48444 301.57

2000 A Top 48413 281.01 48417 374.68Bottom 48414 281.01 48420 374.68

2500/3200 A Top 48416 610.84 48442 795.08Bottom 48419 610.84 48445 795.08

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 35

36

Chassis locking"Disconnected" position locking

By padlocksStandard Price £

By keylocksProfalux 1 lock 48568 35.42

1 lock + 1 lock with same key profile 48569 85.692 locks (different key profiles) 48570 85.69

Ronis 1 lock 48572 35.421 lock + 1 lock with same key profile 48573 85.692 locks (different key profiles) 48574 85.69

Optional disconnected/test/connected position locking 33779 (*)Locking kit without locks for

Profalux, Ronis 48564 17.15Castell*** 48566 57.12

Door interlock (1 part)Right-hand side of chassis 48579 Standard**Left-hand side of chassis 48580 If required**

Racking interlock1 part 48582 24.00

Racking interlock between crank and OFF pushbutton1 part 48585 60.55

Automatic spring discharge before breaker removal1 part 48554 23.78

Breaker mismatch protectionBreaker mismatch protection VDC 33767 Standard

NW08 to NW63drawout circuit breakers (cont.)Chassis locking and accessories

(*) No charge.(**) Supplied as standard, mounted on right hand side.Customer must specify left hand side mounting if required.(***) Castell referencesLock = CL1019Key = CL1062

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 36

37

Chassis accessoriesArc chute cover

3P/4P Standard

Auxiliary terminal shield (CB)800/4000A 3P 48595 Standard

4P 48596 Standard4000b/6300A 3P 48597 Standard

4P 48598 Standard

Safety shutters + locking block800/4000A 3P 48587 Standard

4P 48589 Standard4000b/6300A 3P 48588 Standard

4P 48590 Standard

Shutter locking block (for replacement) Price £2 parts for 800/4000A 48591 84.53

Racking handle (for replacement)47944 37.42

NW08 to NW63drawout circuit breakers (cont.)Chassis locking and accessories (cont.)

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 37

38

NW08 to NW63drawout circuit breakers (cont.)Indication contacts

(*) Actuator to convert to 6 or 9 off, of one type(**) Refer to page 47

M2C

M6C

ON/OFF indication contacts (OF)Block of 4 changeover contacts (6 A - 240 V) 1 block(standard) Price £1 additional block of 4 contacts (2 max.) 48468 99.38

Combined closed/connected contacts for use with 1 auxiliary contact1 contact (5 A - 240 V) (8 max.) 48477 31.53or 1 low-level contact (8 max.) 48478 37.71

"Fault trip" indication contacts (SDE)Changeover contact (5 A - 240 V) 1 (standard)1 additional SDE (5 A - 240 V) 48475 27.41or 1 additional low-level SDE 48476 33.12

Programmable contacts (*) (programmed via Micrologic control unit)2 contacts M2C (5 A - 240 V) 48382 60.55or 6 contacts M6C (5 A - 240 V) 48383 164.49(*) for Micrologic control units P and H only.

Carriage switches (connected / disconnected / test position)Changeover contacts (8 A - 240V) 1 connected position contact (3 max.) 33751 27.811 test position contact (3 max.) 33752 27.811 disconnected position contact (3 max.) 33753 25.50and/or low-level changeover contacts1 connected position contact (3 max.) 33754 33.611 test position contact (3 max.) 33755 33.611 disconnected position contact (3 max.) 33756 33.61Actuator for additional carriage switches 48560 22.40

Spare auxiliary terminals for chassis**3 wire terminal (pack of 30) 47898 111.956 wire terminal (pack of 10) 47899 108.53Jumpers (pack of 10) 47900 11.14

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 38

39

NW08 to NW63drawout circuit breakers (cont.)

Remote operation

Remote ON/OFFGear motor

MCH Price £AC 50/60 Hz 48 V 48522 456.94

100-130 V 48526 456.94200-240 V 48527 456.94250-277 V 48528 456.94380-415 V 48529 456.94440-480 V 48530 456.94

DC 24-30 V 48521 456.9448-60 V 48522 456.94100-130 V 48523 456.94200-250 V 48524 456.94

Instantaneous voltage releasesClosing release Price £ Opening release Price £

Standard XF MXAC 50/60 Hz 12 V DC 48480 75.40 48490 75.40DC 24-30 V DC, 24 V AC 48481 75.40 48491 75.40

48-60 V DC, 48 V AC 48482 75.40 48492 75.40100-130 V 48483 75.40 48493 75.40200-250 V 48484 75.40 48494 75.40277 V AC 48485 75.40 48495 75.40380-480 V AC 48486 75.40 48496 75.40

Communicating XF com MX comAC 50/60 Hz 12 V DC 48448 91.39 48457 91.39DC 24-30 V DC, 24 V AC 48449 91.39 48458 91.39

48-60 V DC, 48 V AC 48450 91.39 48459 91.39100-130 V 48451 91.39 48460 91.39200-250 V 48452 91.39 48461 91.39277 V AC 48453 91.39 48462 91.39380-480 V AC 48454 91.39 48463 91.39

"Ready to close" contact (1 max.)PF Price £

1 changeover contact ( 5 A - 240 V) 48469 111.951 low-level changeover contact 48470 134.80

Electrical closing pushbuttonBPFE Price £

1 pushbutton 48534 85.69

Remote reset after fault tripElectrical reset Res Price £110-130 V AC 48472 99.38220-240 V AC 48473 99.38Automatic reset RARAdaptation 47346 (*)

Remote trippingInstantaneous voltage release

2nd MX Price £ MN Price £AC 50/60 Hz12 V DC 48510 75.40DC 24-30 V DC, 24 V AC 48511 75.40 48501 125.66

48-60 V DC, 48 V AC 48512 75.40 48502 125.66100-130 V 48513 75.40 48503 125.66200-250 V 48514 75.40 48504 125.66277 V AC 48515 75.40380-480 V AC 48516 75.40 48506 125.66

MN delay unitR (non-adjustable) Price £ Rr (adjustable) Price £

AC 50/60 Hz 48-60 V 33680 186.59DC 100-130 V 33684 150.67 33681 186.59

200-250 V 33685 150.67 33682 186.59380-480 V 33683 186.59

(*) No charge

or

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 39

40

Accessories for NW08 to NW63 fixed and drawout circuit breakers

* Requires 2 off adaption fixtures + 1 off cable set.** Complete set.

E46

680

E67

36

Circuit breaker lockingPushbutton locking device Price £

By padlocks 48536 29.71

OFF position lockingBy padlocks

48539 12.58By padlocks and keylocksProfalux 1 lock 48545 47.98

1 lock + 1 lock with same key profile 48546 98.242 locks (different key profiles) 48547 98.24

Ronis 1 lock 48549 47.981 lock + 1 lock with same key profile 48550 98.242 locks (different key profiles) 48551 98.24

Locking kit without locks forProfalux, Ronis 48541 24.00Castell 48543 52.54

Other circuit breaker accessoriesMechanical operation counter

Operation counter CDM 48535 67.40

Escutcheon and accessoriesFixed Price £ Drawout Price £

Escutcheon (spare only) 48601 62.84 48603 62.84Transparent cover IP 54 48604 178.20 48604 178.20Escutcheon blanking plate 48605 57.12 48605 57.12

Mechanical interlocking for source changeoverInterlocking of 2 devices using connecting rods

Complete assembly with 2 adaptation fixtures + rods Price £2 Masterpact NW fixed devices 48612 496.922 Masterpact NW drawout devices 48612 496.92Can be used with 1 NW fixed + 1 NW drawout.

Interlocking of 2 devices using cables*1 adaptation fixture for Masterpact NW fixed devices 47926 319.861 adaptation fixture for Masterpact NW drawout devices 47926 319.861 set of 2 cables 33209 86.94

Interlocking of 3 devices using cables**3 sources, only 1 device closed, fixed or drawout devices 48610 724.242 sources + 1 coupling, fixed or drawout devices 48609 724.242 normal + 1 replacement source, fixed or drawout devices 48608 724.24

Cable-type door interlock1 complete assembly for Masterpact NW fixed or drawout device 48614 399.83Masterpact lifting truck 98003 4569.36

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 40

41

Accessories for NW08 to NW63 fixed and drawout circuit breakers (cont.)

L3

G1

AD 220A

L4

G2

Input

24VDC

Output

24VDC

Special settingsFor circuit breaker deratingCatalogue number to be added to those describing the circuit breakerRating NW08 NW10 NW12 NW16 NW20 NW25 NW32400 47053 47053630 33091 33091 33091800 33092 33092 330921000 33093 33093 330931250 33094 33094 330941600 33095 33095 330952000 33982 339822500 33983Rating NW40 NW40b NW50 NW632000 33982 478212500 33983 47822 478223200 33984 47823 47823 478234000 47824 478245000 47825Note: for ratings In = 100 or 250 A, please consult Merlin Gerin.

Accessories for Micrologic control unitsExternal sensorsExternal sensor for earth-fault protection (TCE) Price £

Sensor rating 400/2000 A 34035 305.331000/4000 A 34036 377.714000/6300 A (for NW40b, NW50, NW63) 48182 726.63

Rectangular sensor for earth-leakage protection500 mm x 150 mm 33574* 780.30

Source ground return (SGR) earth fault protectionExternal sensor (SGR) 33579 371.06MDGF summing module (Compulsary with SGR) 48891 468.08

Voltage measurement input (for breakers supplied via bottom terminals)Voltage measurement input

Fixed 47506 17.46Drawout 48533 17.46

Long-time rating plug (limits setting range for higher accuracy)Standard 33542 28.27Low-setting option 0.4 at 1 x Ir 33543 28.27High-setting option 0.4 at 0.8 x Ir 33544 28.27Without long-time protection 0.8 at 1 x Ir 33545 28.27

Zone Selective Interlocking option for Micrologic P and HZSI Standard

External power supply module24-30 V DC 54440 253.3248-60 V DC 54441 253.32125 V DC 54442 253.32110 V AC 54443 253.32220 V AC 54444 253.32380 V AC 54445 253.32

Battery module1 24 V battery 54446 248.80

Test equipmentMini test kit

33594 551.75

Portable test kitPortable test kit 33595 3680.27Replacement test lead 33590 124.39

* Required Micrologic 7.0 trip units

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 41

42

NW08 to NW63fixed switch-disconnectorsSwitch disconnector selection

The specification of a fixed Masterpactswitch disconnector requires 3catalogue numbers corresponding to: 1 The basic switch disconnector.2 A top connection.3 A bottom connection.A communication option and variousauxiliaries and accessories many alsobe added.

Auxiliaries and accessories:■ For fixed devices: see page 32-33.■ For fixed or drawout devices: see page 40-41.Interlocking: see page 40.

Basic switch disconnector ≤ 4000 A

Basic switch disconnector ≤ 4000b A

1 Basic switch disconnectorType HA

3P Price £ 4P Price £In (A at 40°C) Icm (kA peak for U = 220/690 V)

NW08 800 105 48005 1670.60 48012 2177.69NW10 1000 105 48019 1712.95 48026 2234.52NW12 1250 105 48033 1789.84 48040 2334.83NW16 1600 105 48047 1875.67 48054 2460.77NW20 2000 105 48061 2670.29 48068 3304.43NW25 2500 135 48074 3100.48 48080 4140.28NW32 3200 135 48085 4201.58 48090 5434.19NW40 4000 135 48095 6235.50 48100 7766.79NW40b 4000 187 48108 7306.40 48111 9102.15NW50 5000 187 48114 11896.31 48117 12903.86NW63 6300 187 48120 15014.89 48123 17130.51Type HF

3P Price £ 4P Price £In (A at 40°C) Icm (kA peak for U = 220/690 V)

NW08 800 187 48006 1892.38 48013 2399.47NW10 1000 187 48020 1934.73 48027 2457.42NW12 1250 187 48034 2011.62 48041 2557.93NW16 1600 187 48048 2090.76 48055 2678.08NW20 2000 187 48062 2690.94 48069 3520.63NW25 2500 187 48075 3317.79 48081 4357.60NW32 3200 187 48086 4641.79 48091 5937.93NW40 4000 187 48096 6426.07 48101 7957.36Communication optionModbus COM 48188 278.62

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 42

43

NW08 to NW63fixed switch-disconnectors (cont)

Switch disconnector selection (cont)

2 and 3 Rear connectionVertical connection

3P Price £ 4P Price £800/2000 A Top 48133 40.12 48158 54.83

Bottom 48138 40.12 48163 54.832500/3200 A Top 48134 77.67 48159 102.88

Bottom 48139 77.67 48164 102.884000 A Top 48135 143.98 48160 191.91

Bottom 48140 143.98 48165 191.914000b/5000 A Top 48136 150.79 48161 201.06

Bottom 48141 150.79 48166 201.066300 A Top 48137 287.87 48162 383.83

Bottom 48142 287.87 48167 383.83Horizontal connection

3P Price £ 4P Price £800/2000 A Top 48143 40.12 48168 54.83

Bottom 48148 40.12 48173 54.832500/3200 A Top 48144 77.67 48169 102.88

Bottom 48149 77.67 48174 102.884000 A Top 48145 143.98 48170 191.91

Bottom 48150 143.98 48175 191.914000b/5000 A Top 48146 150.79 48171 201.06

Bottom 48151 150.79 48176 201.06Rear connection accessoriesInterphase barriers

3P/4P (3 parts) 48599 70.82

Brackets for mounting on a backplate2 parts 47829 85.69

2 and 3 Front connection3P Price £ 4P Price £

800/1600 A Top 48128 226.24 48153 301.57Bottom 48130 226.24 48155 301.57

2000 A Top 48124 281.07 48126 374.68Bottom 48125 281.07 48127 374.68

2500/3200 A Top 48129 596.35 48154 795.08Bottom 48131 596.35 48156 795.08

Front connection accessoriesDisconnectable front connection

3P Price £ 4P Price £1600 A 48421 108.53 48424 145.082000/3200 A 48422 148.52 48425 197.64

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 43

44

NW08 to NW63drawout switch-disconnectorsSwitch disconnector selection

The specification of a drawoutMasterpact switch disconnectorrequires 4 catalouge numbers,corresponding to:1 The basic switch disconnector.2 A chassis.3 A top connection.4 A bottom connection.A communication option and variousauxiliaries and accessories many alsobe added.

Auxiliaries and accessories:■ For drawout devices: see page 38-39.■ For fixed or drawout devices: see page 40-41.Interlocking: see page 40.

Basic switch disconnector+ chassis ≤ 4000 A

Basic switch disconnector+ chassis ≤ 4000b A

1 Basic switch disconnectorType HA

3P Price £ 4P Price £In (A at 40°C) Icm (kA peak for U = 220/690 V)

NW08 800 105 48235 1802.11 48242 2302.50NW10 1000 105 48249 1835.54 48256 2335.95NW12 1250 105 48263 1930.28 48270 2426.22NW16 1600 105 48277 2186.61 48284 2948.91NW20 2000 105 48291 2886.49 48298 3732.38NW25 2500 135 48304 3634.31 48310 4743.21NW32 3200 135 48315 5249.19 48320 6593.24NW40 4000 135 48325 7625.24 48330 9636.88NW40b 4000 187 48338 8139.16 48341 10333.59NW50 5000 187 48344 11496.50 48347 14351.20NW63 6300 187 48350 17074.53 48353 19025.66Type HF

3P Price £ 4P Price £In (A at 40°C) Icm (kA peak for U = 220/690 V)

NW08 800 187 48236 2025.00 48243 2524.28NW10 1000 187 48250 2057.32 48257 2558.84NW12 1250 187 48264 2153.17 48271 2648.00NW16 1600 187 48278 2403.93 48285 3166.22NW20 2000 187 48292 3102.71 48299 3949.71NW25 2500 187 48305 3741.25 48311 4960.53NW32 3200 187 48316 5784.13 48321 7158.28NW40 4000 187 48326 7815.83 48331 9827.452 ChassisType HA/HF

3P Price £ 4P Price £800/1600 A 48392 525.48 48404 639.712000 A 48393 643.13 48405 799.632500 A 48394 643.13 48406 799.633200 A 48395 879.66 48407 1113.784000 A 48396 939.01 48408 1197.174000b/6300 A 48397 1872.29 48409 2333.80Communication option

Chassis + Switch disconnectorModbus COM 33852 110.83 48384 278.62

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 44

45

NW08 to NW63drawout switch-disconnectors (cont.)

Switch disconnector selection (cont.)

3 and 4 Chassis rear connectionVertical connection

3P Price £ 4P Price £800/2000 A Top 48133 40.12 48158 54.83800/1600 A type L1 Bottom 48138 40.12 48163 54.832500/3200 A Top 48134 77.67 48159 102.882000 A types H3/L1 Bottom 48139 77.67 48164 102.884000 A Top 48135 143.98 48160 191.91

Bottom 48140 143.98 48165 191.914000b/5000 A Top 48136 150.79 48161 201.06

Bottom 48141 150.79 48166 201.066300 A Top 48137 287.87 48162 383.83

Bottom 48142 287.87 48167 383.83Horizontal connection

3P Price £ 4P Price £800/2000 A Top 48143 40.12 48168 54.83800/1600 A type L1 Bottom 48148 40.12 48173 54.832500/3200 A Top 48144 77.67 48169 102.882000 A types H3/L1 Bottom 48149 77.67 48174 102.884000 A Top 48145 143.98 48170 191.91

Bottom 48150 143.98 48175 191.914000b/5000 A Top 48146 150.79 48171 201.06

Bottom 48151 150.79 48176 201.06Rear connection accessories

Interphase barriers3P/4P (3 parts) 48600 68.54

3 and 4 Chassis front connection3P Price £ 4P Price £

800/1600 A Top 48415 226.19 48441 301.57Bottom 48418 226.19 48444 301.57

2000 A Top 48413 281.01 48417 374.68Bottom 48414 281.01 48420 374.68

2500/3200 A Top 48416 610.84 48442 795.08Bottom 48419 610.84 48445 795.08

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 45

46

Accessories for communication Bus

Modbus pre-wired systemConnection block Price £

CJB306 6 connections RS485 block + power 50963 65.59

CSD309 RS485 9 pins SubD connector 50964 27.72

CablesCDM303 display module cable (L: 3 m) 50960 33.26

CCP303 RS485 Modbus cable + power (L: 3 m) (Micrologic) 50961 24.88CCS303 RS485 Modbus cable (L: 3 m) (Modbus slave) 50962 21.50

CCR301 power + RS485 roll cable (L: 60 m) (Bus Modbus) 50965 255.32

ConverterRS485/RS232 (ACE909) 12 V DC power supply included 50786 P.O.A.RS485/RS232 TSX SCA72 (1)RS485/Ethernet 174 CEV 300-10 (1)RS485/Ethernet (SMS compatible) 3050 EGW2 (2)

Micropower server with automatic notificationMicropower server MPS100 33507 788.0224V DC power supply PS080 232.46

(1) see our Telemecanique catalogue.(2) see our Square D catalogue.

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 46

47

Auxiliary wiring connectors for cassette only supply

The wiring looms for all accessories areassociated with the moving portion, thereforecassette only supply will be made withoutsecondary wiring connectors. To facilitatesecondary wiring connection in advance of themoving portion delivery, the customer isadvised to carry a buffer stock of auxiliaryconnectors for the following:

This stock will be replenished on receipt of the moving portion.

Please note: Due to the constant progress in standards and equipment, the characteristics shown in the texts and images in this documentare only binding once expressly confirmed by ourselves.

3-Wire connector 6-wire connector StrapMasterpact NW

OF, SDE, PF Contacts 1 per contactMX, XF, MN release 1 per releaseMCH 1 per motorRES - electrical reset 1 per unitMicrologic Options

Micrologic A, P 1 per unit 2 per unit 3 per unitComm Module 1 per unitM2C and M6C 1 per unit

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 47

48

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 48

49

Masterpact NWCircuit breakers and switch disconnectors

Order form

To indicate your choices, check the applicablesquare boxes ■■ and enter the appropriateinformation in the rectangles

Basic device QuantityMasterpact type NW

Rated current A

Sensor rating A

Circuit breaker H1, H2, H3,L1

Switch disconnector HA, HF

Number of poles 3 or 4

Option: Neutral on right hand side ■■

Type of device Fixed ■■

Draw out with chassis ■■

Draw out without chassis ■■

Chassis alone ■■

LockingVBP - ON/OFF pushbutton locking ■■

Off position locking

VCPO - by padlocks

VSPO - by keylocks Locking kit without keylocks ■■ Profalux ■■ Ronis ■■

1 lock ■■ 1 lock + 1 lockwith same key profile ■■

2 locks (differrent key profiles) for NW ■■

VSPD - chassis locking in disconnected position

Locking kit without keylocks ■■ Profalux ■■ Ronis ■■

1 lock ■■ 1 lock + 1 lockwith same key profile ■■

2 locks (differrent key profiles) ■■

optional connected/discovered/test position locking ■■

VPEC - door interlock

latch on right hand side of chassis ■■

latch on left hand side of chassis ■■

VPOC - racking interlock ■■

IPA - cable type door interlock ■■

IBPO - racking interlock between crank and OFF pushbutton for NW ■■

DAE - automatic spring discharge before breaker removal for NW ■■

VDC - mismatch protection ■■

Indication contactsON/OFF indication contacts

standard 4 of 6A - 240V AC (10A - 240V AC and low -level for NW)

additional 1 block of 4OF for NW max.2 qty

EF - combined “connected/closed” contacts

1 EF 6A - 240V AC for NW max. 8 qty

1 EF low-level for NW max. 8 qty

SDE - “fault trip” indication contacts

standard 1 SDE 6A - 240V AC

additional 1 SDE 6A - 240V AC ■■ SDE low level ■■

Programmable contacts 2 M2C contacts ■■ 6 M6C contacts ■■

Carriage switches low level ■■ 6A - 240V AC ■■

CE - “connected” position max. 3 for NW qty

CD - “disconnected” position max. 3 for NW qty

CT - ‘test” position max. 3 for NW qty

AC - actuator for additional carriage switches qty

Micrologic control unitA - ammeter

2.0 ■■ 5.0 ■■ 6.0 ■■ 7.0 ■■

P - power meter

5.0 ■■ 6.0 ■■ 7.0 ■■

H - harmonic meter

5.0 ■■ 6.0 ■■ 7.0 ■■TCE - external sensor (CT) for neutral + earth fault protection ■■

TCE - external sensor (CT) for double +neutral protection (Micrologic P andH with 3-poles) ■■

Rectangular sensor 270 X 100mm ■■

for earth-leakage protection 500x150mm ■■

TCW - external sensor ■■

for SGR protection

LT - long time rating plug (standard setting 0.4 to 1 x Ir)

Low setting option 0.4 to 0.8 Ir ■■

High setting option 0.8 to 1 Ir ■■

OFF option (no LT protection) ■■

PTE - external voltage measurement input ■■

AD - external power-supply module ■■

BAT - battery module ■■

CommunicationModbus ■■

eco COM Modbus ■■

ConnectionHorizontal Top ■■ Bottom ■■

Vertical Top ■■ Bottom ■■

Front Top ■■ Bottom ■■

Disconnectable front-connectionadapter NW - fixed ■■

VO - safety shutters on chassis NW ■■

VIVC - shutter position NW ■■

indication and locking

Key for Micrologic control units

2.0: Basic protection (long time + inst.)

5.0: Selective protection (long time + short time + inst.)

6.0: Selective + earth fault protection (long time + short time + inst. + earth fault)

7.0: Selective + earth leakage protection (long time + short time + inst. + earth leakage)

Remote operation

Remote ON/OFF MCH - gear motor VXF - closing voltage release V MX - opening voltage release VPF - ready to close contact low level ■■

6A - 240V AC ■■

BPFE - electrical closing pushbutton ■■

Res - electrical reset optionRAR - automatic reset option ■■

Remote tripping MN - undervoltage release VR - delay unit (non-adjustable) ■■

Rr - adjustable delay unit ■■

2nd MX - shunt release V

AccessoriesCDM - mechanical operation counter ■■

CB - auxiliary terminal shield for chassis ■■

CDP - escutcheon ■■

CP - transparent cover ■■

OP - blanking plate ■■

Brackets for mounting on backplates ■■

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 49

50

Notes

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 50

1. GENERAL - All quotations and tenders are made and all orders areaccepted subject to the following terms and conditions including, whereapplicable, the terms and conditions relating to the provision of services onSite set out in paragraphs 27 to 35.

In these terms and conditions: - “Catalogue Products” shall mean thestandard devices manufactured by us as set out in our publishedcatalogue from time to time; “Contract” shall mean the contract (including,where relevant, the quotation or tender) for supply of goods and/or Workon Site and the acceptance thereof together with all documents to whichreference may properly be made in order to ascertain the rights andobligations of the parties; “Contract Price” shall mean the sum named inthe Contract as the contract price “Credit Limit” shall mean such amountas we may notify to you as being the maximum amount that we will permitto be due from you to us at any time (and such amount may be amendedby us from time to time);” “Erection” shall mean the fixing in position of thevarious items of Plant, their inter-connection and the connection to thePlant of supplies and services all as detailed in the Contract; “Non-Catalogue Products” means all products supplied by us other thanCatalogue Products; “Plant” means all machinery, apparatus, materialsand articles (whether manufactured or supplied by us under a separateContract or not) which are to be erected by us in accordance with theprovisions of the Contract; “Site” means the place where the Plant is to beerected together with so much of the surrounding area as may be used byus in connection with the Work; “Work” means the Erection of the Plant.

2. VALIDITY - Unless previously withdrawn, our quotation or tender isopen for acceptance within the period stated therein or, when no period isso stated, within thirty days only after its date.

3. ACCEPTANCE - The acceptance of our quotation or tender must beaccompanied by sufficient information to enable us to proceed with theorder forthwith, otherwise we shall be at liberty to amend the quotation ortender prices to cover any increase in cost which has taken place afteracceptance. Any samples submitted to you and not returned to our workswithin one month from date of receipt shall be paid for by you.

4. PACKING - Unless otherwise specified in our quotation or tender, allpacking cases, skids, drums and other packing materials must be returnedto our works at your expense and in good condition within one month fromdate of receipt. If not so returned they will be charged for.

5. LIMITS OF CONTRACT - Our quotation or tender includes only suchgoods, accessories and Work as specified therein.

6. PRICES - All prices are unless otherwise stated quoted net ex worksexclusive of VAT. Any variation to prices quoted as a result of governmenttaxes and levies will be for your account.

7. DRAWINGS, ETC. - All specifications, drawings and particulars ofweights and dimensions submitted with our quotation or tender areapproximate only and the descriptions and illustrations contained in ourcatalogues, price lists and other advertisement matter are intended merelyto present a general idea of the goods described therein and none ofthese shall form part of the Contract. After acceptance of our quotation ortender for supply of Non-Catalogue Products, a set of certified outlinedrawings will be supplied free of charge on request.

8. INSPECTION AND TESTS - Our Non-Catalogue products are carefullyinspected and where practicable, submitted to our standard tests at ourworks before despatch. If tests other than those specified in our quotationor tender, or tests in the presence of you or your representative arerequired, these will be charged for. In the event of any delay on your partin attending such tests or in carrying out an inspection required by youafter seven days notice that we are ready, the tests will proceed in yourabsence and shall be deemed to have been made in your presence.

9. PERFORMANCE - We will accept no liability for failure to attain anyperformance figures quoted by us unless we have specifically guaranteedthem, (subject to any tolerance specified or agreed to by us) and in anyevent our liability will be limited to an agreed sum specified in the Contractas liquidated damages. If you have not agreed a sum with us for thispurpose, it will be deemed that no guarantee as to performance has beengiven by us. If the performance figures obtained on any test provided for inthe Contract are outside the acceptance limits specified therein, you will beentitled to reject the goods. Before you become entitled to claim liquidateddamages or to reject the goods, we are to be given reasonable time andopportunity to rectify their performance. If you become entitled to rejectgoods, we will repay you any sum paid by you to us on account of theContract Price thereof. You assume responsibility that goods stipulated byyou are sufficient and suitable for your purpose save in so far as yourstipulations are in accordance with our advice.

10. LIABILITY FOR DELAY IN SUPPLYING - Any times quoted fordespatch or delivery of Catalogue Products are given by us as an estimateonly and shall not be binding upon us. Any times quoted for despatch ordelivery of Non Catalogue Products are to date from receipt by us of awritten order to proceed and all necessary information and drawings toenable us to put the work in hand. We will be entitled to assume thatdrawings we send to you have been approved and that we are authorisedto put work in hand unless you notify us to the contrary within 14 days ofreceipt of the drawings. The time for despatch or delivery shall beextended by a reasonable period if delay in despatch or delivery is causedby instructions or lack of instructions from you or by industrial dispute or byany cause beyond our reasonable control. If a fixed time be quoted fordespatch or delivery of Non Catalogue Products and we fail to despatch ordeliver such products within that time or within any extension thereof underthis clause and, if as a result, you shall have suffered loss, we undertaketo pay for each week of delay liquidated damages at the rate of 1/2 percent, up to a maximum of 5 per cent, of the contract price. Such paymentshall be in full satisfaction of our liability for delay. Any time described asan estimate shall not be construed as a fixed time quoted for the purposesof this clause. In no circumstances shall liquidated or any other damagesfor delay be paid where we have suspended delivery in accordance withClause 16.

11. VARIATIONS - We will use all reasonable endeavours to accommodatevariations which you wish to make but if in our opinion any variationmaterially alters the order you previously gave us we reserve the right tovary the Contract Price, the delivery date and any other terms of theContract as may reasonably be appropriate. The Contract Price will alsobe adjusted in the event of variation or suspension of work by yourinstructions or lack of instructions. For the avoidance of doubt, where wehave assumed that drawings have been approved by you because youhave not notified us to the contrary, any subsequent variation by you tothose drawings will be treated as a variation to which this paragraphapplies.

12. DELIVERY - Unless otherwise specified in our quotation or tender, theprice quoted does not include delivery. Unless otherwise specified, weshall not be responsible for offloading.

13. LOSS OR DAMAGE IN TRANSIT AND OTHER NON-COMPLIANCE -Where we are responsible for delivery we will repair or, at our option,replace free of charge goods lost or damaged in transit; provided that weare given written notification of such loss or damage within 7 days of thedespatch date. You must give us written notification within 7 days ofdelivery if the goods do not comply with the Contract and we will replacesuch goods free of charge. You are not entitled to reject the goods byreason only of short delivery.

14. RISK AND TITLE - The risk of loss or damage to the goods shall passto you on delivery. The goods shall remain our sole and absolute propertyand title in them shall not pass to you until such time as you have paid usfor the goods and for any other goods which are the subject of this or anyother contract with us. You acknowledge that you are in possession of thegoods solely as bailee for us until title in the goods passes to you and, ifrequired by us, until such time you will store the goods separately from allother goods and mark or otherwise identify them as our property. Until titlein the goods passes to you we shall be entitled at any time by notice eitherto require you to return the goods forthwith at your expense, or to enterupon the premises where they are stored (or where they are reasonablythought to be stored) for the purpose of recovering them.

15. TERMS OF PAYMENT - Unless we agree otherwise in writing paymentshall be made 30 days after the goods are despatched or you are advisedthat the goods are ready for despatch or 30 days after work has been

completed or interim work is chargeable. If payment of the Contract Priceor any part thereof is not made by the due date, we shall be entitled: (a) tocharge interest on the outstanding amount at the rate of 4% per annumabove the National Westminster Bank Rate from time to time, accruingdaily; (b) to require payment in advance of delivery of undelivered goodsorcompletion of Work; (c) to refuse to make delivery of any undeliveredgoods whether ordered under the Contract or not and without incurring anyliability whatever to you for non-delivery or any delay in delivery; (d) torefuse to complete Work whether ordered under the Contract or not andwithout incurring liability whatever to you for non completion or any delayin completion; (e) to terminate the Contract and any other contracts we mayhave with you.

16. SUSPENSION OF DELIVERY - In addition to our rights under Clause15, we shall be entitled to suspend delivery to you of any order if, at thetime for delivery, you have already exceeded your Credit Limit or if yourCredit Limit would be exceeded if we made delivery of the order. We willrecommence delivery to you when you reduce the sums outstanding to ussufficiently so as to enable us to make the suspended delivery withoutyour Credit Limit being exceeded. We also reserve the right to suspenddelivery to you of any order if you have failed to make payment by the duedate of sums outstanding to any company within the “Groupe Schneider”group of companies.

17. STORAGE - If we do not receive forwarding instructions, sufficient toenable us to despatch the goods within 14 days after the date ofnotification that they are ready for despatch, you shall take delivery orarrange for storage. If you do not take delivery or arrange for storage, weshall be entitled to: (a) arrange storage either at our own works orelsewhere on your behalf and all charges for storage, for insurance or fordemurrage shall be payable by you. Such charges may be invoiced by usseparately from any invoice for the Contract Price and shall be payable 30days from date of invoice or (b) terminate the Contract and resell orotherwise dispose of the goods (without prejudice to any other rights wemay have against you for breach of Contract or otherwise).

18. DEFECTS AFTER DELIVERY - We will make good, by repair or, at ouroption, the supply of a replacement, defects which, under proper use,appear in the goods within a period of twelve calendar months after thegoods have been delivered and arise solely from faulty design (other than adesign made, furnished or specified by you, or your agents), materials orworkmanship; provided always that defective parts have been returned tous if we shall have so required. We shall refund the cost of carriage onsuch returned parts and the repaired or new parts will be delivered by usfree of charge. Our liability under this Clause shall be in lieu of anywarranty or condition implied by law as to the quality or fitness for anyparticular purpose of the goods and save as provided in this clause, weshall not be under any liability, whether in contract, tort or otherwise, inrespect of defects in goods delivered or for any injury (other than death orpersonal injury caused by our negligence as defined in Section 1 of theUnfair Contract Terms Act, 1977), damage or loss (including indirect orconsequential loss) resulting from such defects or from any work done inconnection therewith.

19. PATENTS - We will indemnify you against any claim for infringement ofLetters Patent, Registered Design, Trade Mark or Copyright (published atthe date of the Contract) by the use or sale of any article or materialsupplied by us to you and against all costs and damages which you mayincur in any action for such infringement or for which you may becomeliable in any such action. Provided always that this indemnity shall notapply to any infringement which is due to our having followed a design orinstruction furnished or given by you or to the use of such article ormaterial in a manner or for a purpose or in a foreign country not specifiedby or disclosed to us, or to any infringement which is due to the use ofsuch article or material in association or combination with any other articleor material not supplied by us. Provided also that this indemnity isconditional on your giving to us at the earliest possible time, notice inwriting of any claim being made or action threatened or brought againstyou and on your permitting us at our own expense, to conduct anylitigation that may ensue and all negotiations for a settlement of the claim.You on your part warrant that any design or instruction furnished or givenby you shall not be such as will cause us to infringe any Letters Patent,Registered Design, Trade Mark or Copyright in the execution of your orderand you will indemnify us against any claim for infringement of any suchintellectual property rights.

20. HEALTH AND SAFETY - You must comply with all instructions,information and warnings which we supply in respect of the goods andensure that such documentation is available to your customers or anyother person handling the goods. Additional copies of the documentationcan be obtained from us on request. You will indemnify us against anyclaim made against us by any third party as a result of your failure tocomply with this Clause.

21. FINAL CERTIFICATE - Upon expiry of the defects liability periodspecified in Clauses 18 and 35, we shall be under no further obligation orliability to you either under the Contract or in tort (including but not limitedto negligence), unless within 14 days thereafter you shall have given uswritten notice of any matter in respect of which we remain obliged or liableto you. You shall issue to us a final certificate to the effect that we havefulfilled all our obligations and liabilities to you immediately upon expiry ofthe said period of 14 days or, in the event that you have given us notice asaforesaid which we have not disputed, immediately upon our having dealtwith the matter(s) specified therein.

22. ARBITRATION - If at any time any question, dispute or differencewhatsoever shall arise between you and ourselves upon, in relation to , orin connection with the Contract, either of us may give to the other notice inwriting of the existence of such question, dispute or difference and thesame shall be referred to the arbitration of a person to be mutually agreedupon, or failing agreement within 30 days of receipt of such notice, ofsome person appointed by the President for the time being of theChartered Institute of Arbitrators.

23. LEGAL CONSTRUCTION - Unless otherwise agreed in writing theContract shall in all respects be construed and operate as an EnglishContract and in conformity with English law and the English Courts shallhave exclusive jurisdiction over any matter arising out of the provisions ofClause 22 (Arbitration).

24. INSOLVENCY ADMINISTRATIVE RECEIVER - If you shall becomebankrupt or insolvent or compound with your creditors or if a proposal ismade for a voluntary arrangement within Part I of the Insolvency Act 1986or if a proposal is made for any other composition, scheme or arrangementwith (or assignment for the benefit of) your creditors, or if a receiver,liquidator, administrator, supervisor or administrative receiver or similarofficer is appointed of all or any part of your business or assets or if apetition is presented or a meeting is convened for the purpose ofconsidering a resolution (or other steps are taken) for your winding up(other than for an amalgamation or reconstruction) or a petition ispresented for an administration order in relation to you, then we shall beentitled to cancel the Contract in whole or in part without prejudice to anyother right or remedy which accrues to us.

25. FORCE MAJEURE - If delivery or completion of Work is delayed bystrikes, lockouts, fire, accidents, defective materials, delays in receipt ofraw materials or bought-in goods or components or any other causebeyond our reasonable control a reasonable extension of time for deliveryor completion of Work shall be granted.

26. STATUTORY AND OTHER REGULATIONS - If the cost to us ofperforming our obligations under the Contract shall be increased orreduced by reason of (a) the making or amendment after the date ofquotation or tender of any law or of any order, regulation, or bye-lawhaving the force of law that shall affect the performance of our obligationsunder the Contract; (b) any rise or fall in the cost of labour or in the cost of

materials or transport above or below such rates and costs ruling at thedate of quotation or tender; the amount of such increase or reduction shallbe added to or deducted from the Contract Price as the case may beprovided that no account shall be taken of any amount by which any costincurred by us has been increased by our default or negligence.

THE FOLLOWING PROVISIONS APPLY IN ADDITION TO THE ABOVECONDITIONS WHERE THE CONTRACT INCLUDES WORK ON SITE.

27. ERECTION DRAWINGS, ETC. - You shall provide us free of chargebefore commencement of the Work with any information, plans ordrawings required for Erection. If the information, plans or drawingsrequired for Erection have not been furnished to us in reasonable time or ifthey do not contain the necessary details, we shall be entitled either tosuspend performance of the Contract until such time as drawings arefurnished or until the necessary details have been provided or to preparesuch plans or drawings ourselves at your cost and in either event the timefor performance of the Contract shall be extended by a reasonable period.We shall have no liability to you whatsoever, whether for negligence orotherwise, in respect of plans or drawings which we prepare due to yourfailure to provide us with your own plans or drawings.

28. SITE FACILITIES AND WORKING CONDITIONS - Our quotation ortender is based on our estimate of the extent of the Work in the light ofinformation (including your Site Safety Regulations) produced to us andunless otherwise specified assumes the following conditions:- (a) You willprovide suitable access to and possession of the Site in reasonable time.(b) The Erection will not be carried out in unhealthy or unsafe conditions.(c) Our employees will be able to obtain suitable and convenient boardand lodging in the neighbourhood of the Site and have access to adequatemedical services. (d) Such equipment cranage, consumable stores, waterand power, scaffolding, lighting, heating and unskilled labour as arespecified in the Contract will be available to us on Site and in reasonabletime, and except as otherwise agreed, free of charge to us. (e) You willprovide us, free of charge, with closed or guarded premises on or near theSite as a protection against the theft and deterioration of the Plant and ofour tools and equipment. (f) We shall not be required to undertake anyconstruction or demolition work.

If these conditions are not satisfied we shall be entitled to charge extra.

29. HOURS OF WORK - Our employees will work normal hours applicableto the engineering industry, Monday to Friday inclusive, local publicholidays excepted. Unless stated to the contrary in our quotation orotherwise agreed, night work, overtime and holiday working are specificallyexcluded.

30. EXTRA COST - Should we incur extra cost owing to variation orsuspension of the Work by your instructions, or your lack of instructions, orto interruptions, delays, overtime, unusual hours, mistakes or work for whichwe are not responsible, or to any specified Site conditions not beingmaintained by you, the Contract Price will be adjusted in accordance withour rates ruling at the time such extra costs are incurred.

31.PREPARATORY WORK - The Plant must be on the Site in reasonabletime. You will provide us in reasonable time with suitable access to theSite and Plant and to all necessary equipment to be provided by you andfurnish us with all information required for making all necessaryconnections to the plant. If you are responsible for preparatory work suchas foundation or other work specified in the Contract as a pre-requisite tocommencement of the Work, it must be completed in reasonable time. Ifwe are responsible for foundation work you will provide us in reasonabletime with all necessary information relating to the work necessary forpreparing suitable foundations. Any extra cost incurred by us which resultsfrom an error or omission in the information furnished by you shall beadded to the Contract Price and paid for accordingly.

32.. LIMITATION ON CONTRACTORS’ LIABILITY WHILST ON SITE - Ifwe, our agents or sub-contractors are on Site for the purpose of theContract then, notwithstanding the provisions of Clauses 18 and 35 we willindemnify you against direct damage or injury to your property or person orthat of others occurring while we are working on Site to the extent causedby the negligence of ourselves, our sub-contractors or agents, but nototherwise, by making good such damage to property or compensatingpersonal injury. Provided that: (a) Our total liability for damage to yourproperty (including damage caused by our breach of contract, tort orbreach of statutory duty) shall not exceed the Contract Price in respect ofdamage to the Plant and in respect of any other damage shall not exceed£1,000,000 or the Contract Price, whichever sum is the greater; b) Weshall not be liable to you for any loss of profit or of contracts or, save asaforesaid, for any loss or damage of any kind whatsoever and whethercaused by our breach of contract, tort, breach of statutory duty orotherwise howsoever. Save as provided in Clause 18 and 35, we shall notbe liable for any damage, injury or loss occurring after our completion ofWork on Site.

33.LIABILITY FOR DELAY IN ERECTION - Any times quoted by us forcompletion of Erection are to date from receipt by us of full and finalinstructions, and sufficient and suitable availability of and access to thePlant to allow us to proceed. The time for completion shall be extended bya reasonable period if delay in completion is caused by instructions or lackof instructions from you or by industrial dispute or by any cause beyondour reasonable control. If a fixed time be quoted for completion of Erectionand we fail to complete within that time or within any extension thereofunder this clause or under Clause 27 (Erection Drawings, Etc.), and if as aresult you shall have suffered loss, we undertake to pay for each week ofdelay liquidated damages at the rate of 1/2 per cent, up to a maximum of 5per cent, of the Contract Price. Such payment shall be in full satisfaction ofour liability for delay.

Any time described as an estimate shall not be construed as a fixed timequoted for the purposes of this clause.

34. TAKING OVER AND ACCEPTANCE OF ERECTION - We shall giveyou notice in writing of the date when the Work is ready for acceptance insufficient time to enable you to make any necessary arrangements forinspection. If the Contract provides for tests on acceptance these shalltake place in the presence of both parties. If in the course of theacceptance it is found that the Work or any part thereof is defective as aresult of defective Erection, assembly or connection of the Plant we shallwith all speed and at our expense make good the defect and thereafter ifyou so require offer the Work for re-inspection and acceptance at ourexpense. As soon as the Work has been completed in accordance with theContract and has been accepted, you shall be deemed to have taken overthe Work and the defects liability period shall start to run. You willthereupon issue a certificate (herein called “taking over certificate”) inwhich you will certify the date on which the Work was completed andpassed the tests (if any). If you do not take the steps necessary for suchacceptance or testing, the Work shall be deemed to have been taken overand the defects liability period shall start to run on receipt by you of writtennotice from us to that effect.

35. DEFECTS LIABILITY PERIOD - We undertake to remedy at ourexpense and with all reasonable speed, any defect in the Work which mayappear during the period of twelve months after taking over by makinggood any such defect. If in consequence of any such defect it is necessaryto repair or replace any part of the Plant any such repair or replacementshall in all respects be at our expense, but not so as to impose upon usany liability greater than the Contract Price. Our liability under this clauseshall be in lieu of any warranty or condition implied by law as to the quality,workmanship, or fitness for purpose of the Work and save as provided inthis clause and Clause 32 (Limitation on Contractors’ Liability Whilst onSite) we shall not be liable to you whether in contract, tort or otherwise forany loss, damage or injury (other than death or personal injury caused byour negligence as defined in the Unfair Contract Terms Act, 1977) resultingfrom any defects in work done or materials provided under the Contract orfrom any services or advice rendered in connection therewith.

36. In the event that any of the provisions of these terms and conditionsare adjudged by any court of competent jurisdiction to be unenforceable(either in whole or in part) we will not be liable for any indirect orconsequential loss or any loss of profits, business, contracts or revenueshowsoever caused.

37. Nothing set out in these terms and conditions shall relieve us from anyliability that we may have under s.12 of the Sale of Goods Act 1970 or forfraudulent misrepresentation under the Misrepresentation Act 1967.

Registered Company Schneider Electric LimitedStafford Park 5, Telford Shropshire TF3 3BL

Issued 1st June 1999

Schneider Standard Terms & Conditions of Sale of Goods (inclusive of erection) United Kingdom

MGLV5705 MASTERPACT (V3) 19/2/05 12:21 pm Page 51

Merlin Gerin is a world leader in the manufacture and supply of high, medium and low voltage products for the distribution, protection, control and management of electrical systems and is focused on the needs of both thecommercial and industrial sectors. The newly launched VDINetwork Solutions offer provides flexible, configurable ethernet systems for all communication needs.

Square D is a total quality organisation and its business is to put electricity to work productively and effectively, protecting people, buildings and equipment. Its low voltageelectrical distribution equipment, systems and services areused extensively in residential and commercial applications.

Telemecanique is a UK market leader and world expert inautomation and control. It provides complete solutions, withit's range of components, Modicon range of high technologyprogrammable controllers (PLCs), multiple fieldbus and ethernet communication networks, HMI, motion control systems, variable speed drives and communications software. In addition, it offers power distribution through prefabricated busbar trunking.

Schneider Electric’s local supportSchneider Electric is committed to supporting its customers at every stage of a project. Our 180 sales engineers, the largestdedicated sales force in the UK electrical industry, operate from 4 customer support centres.

Our sales engineers are skilled at assessing individual requirements and combined with the expert support of our product specialists, will develop the most effective and economical answer taking relevant regulations and standards fully into account.

To access the expertise of the Schneider Electric group, please call 0870 608 8 608. Each customer support centre includesfacilities for demonstrations and training, and presentation rooms fully equipped with audio visual and video, providing excellent meeting facilities.

www.schneider.co.uk

APR 2005MGLV 5705

Industrial systems and solutions showroomSchneider Electric Ltd, University of Warwick Science Park, Sir William Lyons Road, Coventry CV4 7EZ

Building systems and solutions showroomSchneider Electric Ltd, Stafford Park 5, Telford, Shropshire TF3 3BL

Energy and Infrastructure systems and solutions showroomSchneider Electric Ltd, 123 Jack Lane, Hunslet, Leeds LS10 1BS

Product showrooms

Local customer support centres

Fax 0870 608 8 6060870 608 8 608Nationwide support on one number - call the Customer Information Centre on

member of

.co.uk

ScotlandSchneider Electric LtdUnit 11000Academy Business ParkGower StreetGlasgow G51 1PR

South WestSchneider Electric LtdPO Box 41Langley RoadChippenhamWiltshire SN51 1JJ

North WestSchneider Electric Ltd8 Brindley RoadCity Park Business VillageCornbrook Manchester M16 9HQ

MGLV5705 MASTERPACT (V3) 21/2/05 4:08 pm Page 52