application air cooled mini solution fan coil unit chilled water … · 2014. 9. 30. · daikin...

20
PCXCW14 Products manufactured in an ISO cerfied facility. This document contains the most current product informaon as of this prinng. @2014-06 Chilled Water System Solution Product Catalogue PRODUCT SYSTEM Air-Cooled Air Cooled Mini Chiller Fan Coil Unit Applicaon Soluon

Upload: others

Post on 10-Feb-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • PCXCW14

    Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.

    @2014-06

    Chilled Water SystemSolution Product Catalogue

    PRODUCT SYSTEMAir-Cooled

    Air Cooled Mini Chiller

    Fan Coil Unit

    Application

    Solution

  • Cooling & Heating Capacity

    R22UAE

    R407CUAP

    FWE-E

    FWC-C

    FUD-B

    4.0 6.0 8.0 10.0

    kW

    20.0 25.0 30.0 40.0

    Products OverviewContents

    01

    Application

    04

    Air Cooled Mini Chiller

    13

    Solution

    Fan Coil Units

    Wall Mounted

    19

    Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice.

    15.0 50.0

    025/030/040/050/060/080/100/120/150

    060/080/100/120/150

    020/025/030/040/050/055

    020/025/030/040/050/055

    R410AUAQ

    Ceiling Cassette Compact Type (600 x 600)

    Ceiling Cassette Type (900 x 900)

    Ceiling Cassette Type (900 x 900) With Brushless DC Motor

    Ceiling Convertible Type

    Ceiling Concealed Type Ducted Blower Type

    20 21 22 24

    25 27

    020/025/030/040/050/060/080/100/120/150

    020/025/030/040/050/060/080/100/120/150

  • Application

    AIR COOLED MINI CHILLER APPLICATION EXAMPLES :

    CHILLED WATER SYSTEM SOLUTION ADVANTAGES :

    Chilled Water System Solution

    Advantages

    Long Piping Application

    Quiet Operation

    Less RefrigerantHandling

    No Necessity To Use Cooling Towers

    Versatility InSystem Coupling

    Simple On SiteInstallation

    LONG PIPING APPLICATION

    Daikin chilled water system has no limitation in piping lengths unlike direct expansion refrigerant system. As long as the water pump head pressure is sufficient to pump the water through the water pipe network, the chiller can be installed far away from the fan coil units. Daikin Mini Chiller is designed to support water operating pressure up to 1000kPa. With such high design pressure, Daikin mini chiller is capable of fulfiling In the case where the Mini Chiller's built in pump head is insufficient to support the overall friction loss, additional pump can be installed to cater for higher pump head requirement.

    Private Houses

    Hotels

    Gym Centres

    @Office Rooms Coffee Houses

    Restaurant

    Universities & Halls

    Availablility of cooling only & heatpump

    models

    Centralized ControlNetwork supports up

    to 50 chillers and 120 FCU

    Multiple tempratureZone Control

    Operation can be managedaccording to zones for different comfort need

    Serviceability & ErrorCode Troubleshooting

    Easy access for servicing all components. Error codedisplayed on control panel

    for troubleshooting purpose

    Energy Saving Programmable Timer

    Customizable operationschedule of chiller and FCU

    based on requirement topromote energy saving

    Master/Slave OptionControl based on

    network grouping orapplication

    Dry Contact BMSCompatibility

    Abiblity to be integratedwith BMS

    1 2

  • QUIET OPERATION

    Quiet operation due to fan coil unitsand chiller can be placed far away from room

    Daikin mini chiller is designed for air cooled application where is no necessity to use the cooling tower especially for small and medium size of chilled water application

    NO NECESSITY TO USE COOLING TOWERS

    › Less Refrigerant Handling› No Refrigerant Used In Occupied Space› Water As Cooling Medium

    Refrigerant is only circulating within the mini chillerunit. Meanwhile, water acts as the cooling medium for FCU. When there is less refrigerant used, the scope of care on refrigerant handling is smaller. In case when there is a leak water is definitely easier to handle in term of process and cost.

    LESS REFRIGERANT HANDLING

    VERSATILITY IN SYSTEM COUPLING

    Chilled water system is designed with versatility in system coupling where there is no limitation in the number of fan coil unit coupling with mini chiller as long as they meetthe designed capacity requirament & water flow rate. System coupling of one to one and one to many configurations

    ONE TO ONE

    ONE TO MANY

    SIMPLE ON SITE INSTALLATION

    Refrigarent

    The Daikin mini chiller is fully assembled, completewith all necessary components in one unit like waterpump, internal wiring, fully charged with refrigerantand undergo strict testing and quality check before delivery. Only connection to water piping and power supply is required at site.

    EASY INSTALLATION AND MAINTENANCE :

    FACTORY PRECHARGED REFRIGERANT

    Each heat exchanger in the chiller is brazed and tested against leakages through dried air at 30 bars. After that, another process of system vacuuming is done before it is accurately charged with refrigerant to ensure optimum performance. Thus, it saves the hustles of field charging by installers.

    Brazed Plate Heat ExchangerPlate type heat exchanger has acompact structure and a high levelof heat exchange efficiency

    FILTER DRIER Remove dirt and moisture in the refrigerant circuit.

    MULTISTAGE END SUCTION WATER PUMPImpeller and all movable parts in contact with the water are made of stainless steels.

    Diaphragm Expansion TankPrevent damage of hydraulic components and cracking of piping due to expansion of hot water in the pipes.

    WATER STORAGE TANK Prevent the compressor from switching ON/OFF too frequently during low load conditions such as night time.NOTE: Model UA(E/P)080~150C/CR water tank is offered as an optional device.

    SERVICEABILITY & ERROR CODE FOR EASE OF TROUBLESHOOTING

    By opening the front panel, one can access and service all the components in the chiller. The chiller is equipped with self diagnosis function which allow the chiller panel to display total of 19 type of faulty occurred in the system by showing different error code on the LCD screen of the panel.

    Air Cooled Mini Chiller

    Mini chiller can be installed far away from fan coil units

    INTEGRATED HYDRONIC COMPONENTSDaikin Mini Chiller is fully integrated and equipped with key hydronic components such as expansion tank, water tank, brazed plate heat exchanger and water circulating pump. As all hydronic components are assembled and tested in the factory, installation of additional component on site can be eliminated.

    3 4

    Mini ChillerAir Cooled

  • PARALLEL INSTALLATIONDaikin Mini Chiller provides flexibility in adding capacity for building extension. This can be done by installing the mini chiller in parallel connection.A network of up to 50 chillers is possible to be connected in a system. For ease of controlling and setting, Daikin Mini Chiller panel implement Master and Slave function. This function allows user to monitor all the settings on the slave units at the master unit.

    Supported Up To 50 Units Of Chiller

    Chiller 0 Chiller 2Chiller 1

    Chiller Panel 0(Master)

    Chiller Panel 1(Slave)

    5 way wire (CM8)ChillerCommunication Bus

    SUPERIOR RELIABILITY :

    SCROLL COMPRESSORScroll Compressors are used for the units to offer a quieter and more reliable performance over a wide operating temperature range. (Except UAE020C/CR which uses rotary compressor).

    For UA(E/P) 030, 040, 050, 060, 080, 100, 120, 150 CR, phase protector is provided to prevent the compressor from rotating in the wrong directions.

    State-Of-The-Art Components

    CopelandCompliant ®

    Scrolls

    High EfficiencyMotor

    Quiet ShutdownDevice

    ANTI-FREEZE PROTECTIONThe chiller unit has several anti-freeze protection features:

    1. Built-in heater in BPHEThe BPHE has a strip heater around it to prevent water freezing inside.

    2. Anti-Freeze sensorBPHE can avoid the frosting as the anti-freeze sensor will send the signal to cut out the compressor if the water temperature becomes too cold.

    3. Water pressure differential switchThis protection feature will ensure there is water flow in pipings when the chiller is in operation. Otherwise, the compressor will cut out immediately.

    MICROPROCESSOR CONTROLDaikin chillers are equipped with microprocessor controller that will control and regulate the operation of the unit.

    Besides that, the controller that contains the well developed algorithm will provide protection to the chiller by accurately sensing the key temperatures in both the water and refrigerant circuit. Should there be any abnormal reading received by controller, an alarm signal will be sent to chiller panel, followed by protection action plans such as to stop the operation of compressor, condenser fan motor or circulating water pump.

    BRAZED PLATE HEAT EXCHANGER (BPHE)The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to maximize possible heat exchange efficiency.

    AISI 316 stainless steel BPHE

    SAFETY PROTECTIONThe safety protections provided for the Daikin chiller are:• High & Low Pressure Switches • Anti-Freeze Protection Sensor• Discharge Temperature Sensor• Over Pressure Relief Valve• Water Pressure Differential Switch• Anti-Freeze Heater on BPHE• Compressor Water Pump & Fan Motor Overload Protector

    EFFICIENCY AND PERFORMANCE :

    CHILLER CONTROL PANELThe chiller panel controller is designed to control the chiller operation. This device allows the user to have customized control for each connected unit.

    Each chiller will have a chiller control panel that comes as a standard accessory. At the same time, the chiller control panel is able to be installed remotely through the cable up to a distance of 100 meters. Example, the chiller panel can be installed in a centralized plant control room for the building.

    The chiller control panel has been designed taking into consideration of the user friendly and yet versatile control features.

    Features:• Whole system configuration.• Unique parameter settings.• Operation status display.• Tracing fault record (offer quick troubleshooting solutions).

    • The display is shown in an 8-lines graphical LCD display. There are 8 dedicated keys available in the panel.• Menu selection.• Navigation on the screen.• Modification of the selected value.

    5 6

  • LOAD BALANCING CONTROLFor UA(E/P)080 ~ 150 C/CR both compressors will cut in and cut out depending on their accumulative operating time. This sequencing control feature will ensure no single compressor is overload in operation as well as to ensure longer reliability of compressors.

    CAPACITY STEP CONTROLUA(E/P)080 ~ 150 C/CR has been designed with two separate refrigerant circuits, i.e. it has two compressors. By doing so, the unit has part loading capabilities, i.e. 0-50-100% of rated capacity. This will improve the reliability and energy efficiency of the unit, especially during low loading operations.

    ANTI CORROSION GOLD ALUMINUM FINGold Aluminum fin is offered as the standard material of the condenser heat exchanger of this series of chiller.

    EFFICIENCY AND PERFORMANCE :

    Air-Cooled Mini Chiller

    This innovative air cooled chiller by Daikin was designed with one purpose in mind, which is to offer cost and energy saving for users.

    Model: UAQ 030/040/050/055 CR

    BETTER PERFORMANCE

    • Usage of higher efficient R-410A rotary compressors in tandem configuration• Tight tolerances between moving parts resulting in high compressor volumetric efficiency• Minimize mechanical losses• Minimize gas flow losses and turbulence• Optimize compressor oil return

    CAPACITY STEP CONTROL

    3 steps compressor loading (0%-40%-60%-100%) for UAQ 040 CR & UAQ 050 CR 2 steps compressor loading (0%-50%-100%) for UAQ 030 CR & UAQ 055 CR

    ELIMINATION OF WATER TANKCombining the Tandem Compressors technology with the algorithm of the microprocessor control, water tank can be eliminated in most instances.

    CHOICES OF SINGLE PHASE AND 3 PHASE POWER SUPPLY CONNECTION• Usage of single phase power supply compressors and circulating water pump.• Offers flexibility to field installation.

    water

    Ref.1 Ref.2 Ref.1 Ref.1Ref.2

    waterwater water

    Chiller Panel Comes AsThe Standard Controller

    Compatible With Smart Manager

    PARALLEL INSTALLATIONA network up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.

    TRUE DUAL CIRCUITS BPHEApply sophisticated technology of true dual circuit

    BPHE.

    The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. These advantages have made the product the natural choice for flexible chillers, climate control applications and high-precision systems food cooling cabinets in supermarkets.

    FLEXIBILITY :

    7 8

  • R22 COOLING MODEL

    MODEL

    NOMINAL COOLING CAPACITY

    NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hWWA

    W/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSORTYPESTAGE OF CAPACITY CONTROL

    PIPINGTYPECONNECTIONHEAD COOLING

    mmkPa

    TANKCAPACITY / VOLUME MATERIAL

    L

    UAE020C UAE025C UAE030C UAE040C UAE050C UAE060C

    INDO

    OR

    UN

    IT

    20,000 24,200 30,000 39,500 48,500 54,0005,860 7,090 8,790 11,580 14,210 15,8302,650 2,680 3,580 4,490 5,080 5,77012.25 12.17 16.41 9.67 9.75 12.012.21 2.65 2.48 2.58 2.80 2.74

    1.25 1.80 1.88 2.80 3.15 3.30220-240/1/50 380-415/3/50

    CAPILLARY TUBE

    R2257 57 58 59 59 59

    790 x 1,160 x 460920 x 1,270 x 570

    1,140 x 1,160 x 4601,551 x 1,270 x 570

    116 123 126 182 189 1960.29 / 1.03 0.33 / 1.20 0.42 / 1.51 0.53 / 1.90 0.67 / 2.40 0.76 / 2.73

    ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%

    THREAED25.4

    79 92 86 114 90 9222 40

    MILD STEEL WITH ZINC

    R22 AIR COOLED MINI CHILLER SPECIFICATIONR22 HEATPUMP MODEL

    MODEL

    NOMINAL COOLING CAPACITY

    EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hW

    W

    W/WW/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT

    NOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSOR TYPESTAGE OF CAPACITY CONTROL

    PIPING

    TYPECONNECTION

    HEAD COOLINGmmkPa

    TANK CAPACITY / VOLUME MATERIAL

    L

    UAE020CR UAE025CR UAE030CR UAE040CR UAE050CR UAE060CR

    INDO

    OR

    UN

    IT

    19,000 23,000 27,500 38,000 44,000 50,0005,570 6,740 8,060 11,140 12,900 14,650

    22,000 27,000 35,000 43,000 50,000 55,000

    2,600 2,790 3,440 4,390 5,100 5,320

    2.20 2.52 3.44 2.63 2.48 2.63

    1.43 1.75 1.83 3.50 4.10 4.00220-240/1/50 380-415/3/50

    CAPILLARY TUBE

    R2257 57 58 59 59 60

    790 x 1,160 x 460920 x 1,270 x 570

    1,140 x 1,160 x 4601,551 x 1,270 x 570

    116 123 128 189 197 2030.26 / 0.93 0.31 / 1.12 0.39 / 1.39 0.56 / 2.00 0.62 / 2.20 0.64 / 2.50

    ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%

    THREAED25.4

    79 94 92 118 104 110

    22 40MILD STEEL WITH ZINC

    AA

    W

    NOMINAL HEATPUMP CAPACITY Btu/hW 6,450 7,910 10,260 12,600 14,650 16,120

    2,530 2,670 3,440 4,230 5,190 5,580

    11.7811.62

    12.1712.70

    17.2717.25

    9.059.14

    9.779.72

    12.6011.50

    2.48 2.84 3.43 2.87 2.87 3.03

    I/s/m3/hrHEATPUMP 0.31 / 1.12 0.38 / 1.38 0.49 / 1.75 0.56 / 2.00 0.62 / 2.20 0.76 / 0.72

    HEATPUMP 79 86 73 103 85 87kPa

    MODEL

    NOMINAL COOLING CAPACITY

    EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hW

    W

    W/WW/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT

    NOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSORSTAGE OF CAPACITY CONTROL

    PIPING

    TYPECONNECTION

    HEAD COOLINGmmkPa

    INDO

    OR

    UN

    IT

    NORMAL RUNNING CURRENT AA

    W

    NOMINAL HEATPUMP CAPACITY Btu/hW

    I/s/m3/hrHEATPUMP

    HEATPUMP kPa

    UAE080CR80,000

    23,45095,000

    8,750

    2.76

    5.00 x 2

    63

    1,245 x 1,500 x 900

    1,452 x 1,732 x 1,032328

    27,8408,490

    18.4018.90

    3.18CAPILLARY TUBE

    380-415/3/50R22

    95,000

    27,840105,000

    10,310

    2.51

    30,77011,100

    18.9017.10

    2.98

    UAE100CR

    5.40 + 5.30

    63

    340

    UAE120CR113,000

    33,120120,000

    12,370

    2.74

    35,17012,070

    26.6026.80

    2.86

    7.60 x 2

    67

    480

    UAE150CR138,000

    40,450132,000

    15,020

    2.82

    38,69014,320

    31.4032.20

    2.58

    6.50 x 2

    67

    560

    1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282

    1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20

    1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20SCROLL

    0 - 100% 0 - 100% 0 - 100% 0 - 100%THREAED

    31.75

    254 173 188 157229 144 188 157

    ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

    EVAPORATOR

    CONDENSOR

    TEMPERATURE

    ENTERING

    LEAVING

    AMBIENT

    COOLING

    12°C

    HEATING

    40°C

    7°C 45°C

    35°C 7°C / 6°C

    MODEL

    NOMINAL COOLING CAPACITY

    NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hWWA

    W/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSORTYPESTAGE OF CAPACITY CONTROL

    PIPINGTYPECONNECTIONHEAD COOLING

    mmkPa

    INDO

    OR

    UN

    IT

    UAE080C65,00024,9108,87017.00 8.87

    3.90 x 2380-415/3/50

    TXV

    R22631,245 x 1,500 x 900

    1,452 x 1,732 x 1,032328

    0.29 / 1.03SCROLL

    0 - 100%THREAED31.75

    229

    UAE100C95,00027,84010,59018.502.63

    4.60 x 2

    63

    3400.33 / 1.20

    0 - 100%

    229

    UAE120C116,00034,00011,37025.832.99

    6.00 x 2380-415/3/50

    67

    4800.42 / 1.51

    0 - 100%

    188

    1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282

    UAE150C138,00040,45014,22031.802.84

    7.10 x 2

    67

    5600.53 / 1.90

    0 - 100%

    157

    ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

    EVAPORATOR

    CONDENSOR

    TEMPERATURE

    ENTERING

    LEAVING

    AMBIENT

    COOLING

    12°C

    HEATING

    40°C

    7°C 45°C

    35°C 7°C / 6°C

    9 10

    HEATPUMPCOOLINGNORMAL TOTAL INPUT POWER

    HEATPUMPCOOLING

    NORMAL RUNNING CURRENT

    HEATPUMPCOOLING

    NORMAL TOTAL INPUT POWER

    HEATPUMPCOOLING

  • R407C COOLING MODEL

    MODEL

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKING

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmmmm

    COMPRESSOR

    PIPINGTYPE

    TANKCAPACITY / VOLUME MATERIAL

    L

    UAP025C UAP030C UAP040C UAP050C UAP060C

    INDO

    OR

    UN

    IT

    Btu/h 23,000 26,900 38,500 47,000 50,000NOMINAL COOLING CAPACITYW 6,740 7,880 11,280 13,920 14,650

    NORMAL TOTAL INPUT POWER (COOLING) W 2,950 3,770 4,680 5,430 6,040NORMAL RUNNING CURRENT (COOLING) A 13.30 17.41 9.62 10.20 11.28EER W/W 2.29 2.09 2.41 2.56 2.43

    REFRIGERANT CHARGE kg 1.72 1.63 3.00 3.30 3.20POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50

    REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE

    REFRIGERANT TYPE R407C57 58 59 59 60

    790 x 1,160 x 460920 x 1,270 x 570

    1,140 x 1,160 x 4601,551 x 1,270 x 570

    UNIT WEIGHT kg 123 126 188 189 196NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.31 / 1.11 0.38 / 1.36 0.53 / 1.90 0.64 / 2.30 0.69 / 2.50

    TYPE SCROLLSTAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%

    THREAEDCONNECTION mm 25.4HEAD COOLING kPa 94 93 117 93 110

    22 40MULTISTAGE END SUCTION

    R407C AIR COOLED MINI CHILLER SPECIFICATION

    ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

    EVAPORATOR

    CONDENSOR

    TEMPERATURE

    ENTERING

    LEAVING

    AMBIENT

    COOLING

    12°C

    HEATING

    40°C

    7°C 45°C

    35°C 7°C / 6°C

    MODEL

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKING

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmmmm

    COMPRESSOR

    PIPINGTYPEIN

    DOO

    R U

    NIT

    Btu/hNOMINAL COOLING CAPACITY

    WNORMAL TOTAL INPUT POWER (COOLING) WNORMAL RUNNING CURRENT (COOLING) AEER W/W

    REFRIGERANT CHARGE kgPOWER SOURCE (OUTDOOR) V/Ph/Hz

    REFRIGERANT CONTROL (EXPENSION DEVICE)

    REFRIGERANT TYPE

    UNIT WEIGHT kgNOMINAL WATER FLOW RATE COOLING I/s/m3/hr

    TYPESTAGE OF CAPACITY CONTROL

    CONNECTION mmHEAD COOLING kPa

    UAP080C

    80,00023,4509,43018.002.49

    3.90 x 2380-415/3/50

    TXV

    R407C63

    1,245 x 1,500 x 9001,452 x 1,732 x 1,032

    3401.14 / 4.10

    SCROLL0 - 50 - 100%

    THREAED31.75

    229

    UAP100C

    90,00026,38011,21019.222.35

    3.80 x 2

    63

    3401.25 / 4.50

    229

    0 - 50 - 100%

    UAP120C

    115,00033,73012,17026.502.77

    5.60 x 2

    67

    4801.67 / 6.00

    188

    0 - 50 - 100%

    1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282

    UAP150C

    137,00040,15014,97033.002.68

    6.00 x 2

    67

    5602.00 / 7.20

    157

    0 - 50 - 100%

    R407C HEATPUMP MODEL

    MODEL

    NOMINAL COOLING CAPACITY

    (COOLING)

    (HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hW

    W

    W/WW/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT

    NOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSOR TYPESTAGE OF CAPACITY CONTROL

    PIPING

    TYPECONNECTION

    HEADCOOLING

    mmkPa

    UAP060CR UAP080CR UAP100CR UAP120CR UAP150CR

    INDO

    OR

    UN

    IT

    50,000 74,000 87,500 110,000 130,00014,650 21,690 32,240 38,10055,000 90,000 96,000 118,000 144,000

    5,570 9,350 12,750 16,100

    2.33 2.41 2.55 2.40

    4.00 3.70 X 2 4.80 + 4.70 5.80 x 2 6.40 x 2380-415/3/50 380-415/3/50

    CAPILLARY TUBE

    R407C60 63 63 67 67

    1,140 x 1,160 x 4601,551 x 1,270 x 570

    1,245 x 1,500 x 900 1,245 x 1,800 x 1,150

    203 340 340 480 5600.64 / 2.30 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80

    0 - 100% 0 - 50 -100%THREAED

    25.4110 263 193 188 172

    (COOLING) (HEATPUMP)

    AA

    W

    NOMINAL HEATPUMP CAPACITY Btu/hW 16,120 26,380 28,140 34,500 42,2006,280 8,990 12,630 15,900

    11.6011.50

    18.9019.00

    27.1026.10

    34.4034.80

    2.89 2.83 2.71 2.62

    I/s/m3/hrHEATPUMP 0.78 / 2.80 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80

    HEATPUMP 87 170 170 188 172

    SCROLL

    kPa

    25,640

    11,11011,100

    19.0019.102.312.53

    1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282

    0 - 50 -100% 0 - 50 -100% 0 - 50 -100%

    31.75

    ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

    EVAPORATOR

    CONDENSOR

    TEMPERATURE

    ENTERING

    LEAVING

    AMBIENT

    COOLING

    12°C

    HEATING

    40°C

    7°C 45°C

    35°C 7°C / 6°C

    R410A HEATPUMP MODEL

    MODEL

    NOMINAL COOLING CAPACITY

    (COOLING)

    (HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE

    Btu/hW

    W

    W/WW/W

    kgV/Ph/Hz

    SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT

    NOMINAL WATER FLOW RATE

    HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH

    dBAmm

    COOLING

    mmkg

    I/s/m3/hr

    COMPRESSORTYPESTAGE OF CAPACITY CONTROL

    PIPING

    TYPECONNECTION

    HEAD COOLINGmmkPa

    TANK CAPACITY / VOLUME MATERIALL

    UAQ020CR UAQ025CR UAQ030CR UAQ040CR UAQ050CR UAQ055CR

    INDO

    OR

    UN

    IT

    15,700 21,000 24,800 34,000 41,600 45,0004,600 6,150 7,270 10,000 12,200 13,200

    21,500 25,000 32,500 43,000 48,000 55,000

    2,590 2,790 3,630 4,650 5,150 5,440

    1.76 2.23 1.90 2.00 2.30 2.40

    1.20 1.725 2.20 4.30 4.20 4.30220-240/1/50 380-415/3/50

    CAPILLARY TUBE

    R410A58 59 57 59 59 61

    790 x 1,160 x 460920 x 1,270 x 570

    1,140 x 1,160 x 4601,551 x 1,270 x 570

    128 128 128 195 195 1950.24 / 0.86 0.28 / 1.00 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70

    ROTARY TANDEM ROTARY0-100%

    THREADED25.4

    90 98 93 90 74 70

    22 40MILD STEEL WITH ZINC

    (COOLING) (HEATPUMP)

    AA

    W

    NOMINAL HEATPUMP CAPACITY Btu/hW 6,300 7,330 9,530 12,600 14,070 16,1202,620 2,760 3,830 5,000 5,310 5,490

    11.7611.93

    12.7012.90

    16.8816.32

    7.447.20

    7.907.83

    8.188.38

    2.43 2.63 2.62 2.71 2.73 2.96

    I/s/m3/hrHEATPUMP 0.32 / 1.16 0.35 / 1.25 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70

    HEATPUMP 73 90 80 71 64 53

    0-100% 0-50-100% 0-40-60-100% 0-50-100%0-40-60-100%

    kPa

    ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

    EVAPORATOR

    CONDENSOR

    TEMPERATURE

    ENTERING

    LEAVING

    AMBIENT

    COOLING

    12°C

    HEATING

    40°C

    7°C 45°C

    35°C 7°C / 6°C

    R410A AIR COOLED MINI CHILLER SPECIFICATION

    11 12

    NORMAL TOTAL INPUT POWER

    NORMAL RUNNING CURRENT

    NORMAL TOTAL INPUT POWER

    NORMAL RUNNING CURRENT

  • SMART MANAGER CONTROLLER

    Chiller Network BUSFan Coil Network BUS

    By adopting the Daikin chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restaurant, hotel and shopping complex can be controlled and managed from just one point, that is through the Smart Manager.

    The Smart Manager is acting as a central command to manage the operation of both the chilled water fan coil units and the chillers.

    Besides allowing the user to have customized control for each connected unit, the Smart Manager is also able to manage the overall system operating mode of all units based on the air conditioning system load demand of the building.

    SUPPORTED UP TO 50 CHILLERS & 120 FAN COIL UNITSThrough the versatile Smart Manager controller, the operation of each equipments in the Daikin chilled water system connected through the chiller Bus and Daikin own proprietary NIM BUS can be managedand controlled.

    NIM

    CHILLER CHILLER CHILLER

    Up to50 unitsof Chiller

    Up to120 unitsof FCUs

    AB

    AB

    CHILLER BUS

    NIM BUS

    Smart Manager Controller

    NIM NIM

    FCU FCU FCU WIREDCONTROLLER

    CHILLERPANEL

    CHILLERPANEL

    CHILLERPANEL

    Alarm 1(Ch 0)

    Comp 1 overload

    01/01/00 12.00am

    DISPLAY UP TO 46 TYPES OF CHILLER FAULT /ALARM AND 6 TYPES OF FCU FAULT / ALARM

    Whenever a fault occurred in either the chiller or fan coil unit, a signal will be sent to Smart Manager and an alarm message willappear on the LCD, showing type of alarm, alarm occured time,date and unit.

    This will greatly ease the troubleshooting process and thus reduce the valuable time of service technicians.

    As soon as the fault is solved, the alarm will automaticallydissolve from the LCD.

    8.00am

    9.00am

    10.00am

    11.00am

    12.00am

    1.00pm

    2.00pm

    3.00pm

    4.00pm

    5.00pm

    6.00pm

    7.00pm

    8.00am

    9.00am

    10.00am

    11.00am

    12.00am

    1.00pm

    2.00pm

    3.00pm

    4.00pm

    5.00pm

    6.00pm

    7.00pm

    Time

    FWC

    FWK

    FWE 2

    FWE 1

    FWW

    Uni

    t

    The operation of the chiller and each fan coil unit can be preset to operate and tostop at different time schedule and at different day of a week. Taking considerationof the fact that certain rooms in a buildingwill be empty at certain period of the day,setting timer to On and to Off the operationof units in those areas will greatly reducethe energy cost of the building.

    At the same time, Smart Manager allowssetting of up to five sets of 7 days programmable operation schedules (2 On/Off timer per day) for each fan coil unit

    ENERGY SAVING PROGRAMMABLE TIMER

    13 14

  • If the priority setting is being preset to fan coil unit, the

    operating mode of the complete Daikin chilled water system can be synchronized to operate under one same mode. This is achievable through the unique feature called “Threshold Value Setting”

    Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet.

    Example,In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode of all chillers to HEAT mode. Requirement of users will be met.

    FWW

    FWE 2FWK

    FWC

    FWE 1

    THRESHOLD VALUE SETTING

    • Heat Treshold •

    Chiller to operate atHeat Mode

    Chiller to operate atCool Mode

    0 1 2 3 4 5 6 7 8 9 10

    • Cool Treshold •

    Depending on the application requirement, Smart Manager controller offers the flexibility to allow user to set the priority on the operation of fan coil unit and Chiller in a complete Daikin chilled water product system.

    If priority is set to fan coil unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being set, all fan coil units will be OFF if chillers are OFF.

    PRIORITY SETTING

    When there is power failure occurs during operation, Smart Manager Controller will load the last state memory from EEPROM after power On reset.

    Besides, extra memory space inside the Smart Manager controller will allow user to view the previous alarm records even though its have been dissolved. This useful information will benefit the service technician to view the history of maintenance record done to the unit.

    MEMORY BACKUP (EEPROM),ALARM MEMORY FOR CHILLER AND FCU KEY PARAMETER DISPLAY

    For easy serviceability and maintenance, Smart Manager Controller's is able to display the key parameter such as defrost and compressor discharge sensor temperature, water in/out temperature, status of compressor On/Off, Cool/Heat mode water in temperature, etc. Thus, it reduces the cumbersome of requiring the service technicians to physically go to site of chiller installation to do the troubleshooting process.

    A Daikin chilled water product system with key parameters that were set by personnel to optimize operating conditions will need to be protected against any unauthorized disturbance or changes. The built in “Password Settings” feature will prevent the losing of key parameter settings in the Smart Manager controller as well as the chiller panel

    PASSWORD PROTECTION FOR ADVANCED PARAMETER SETTINGS (CHILLER)

    HOLIDAY SETTINGSHoliday 1Holiday 2Holiday 3Holiday 4Holiday 5

    Set Holiday 1Month : 1Day : 1Duration : Disable

    While designing the Smart Manager, the practical aspects of equipment application were always the key points to be considered. Thus resulting in the creation of “Holiday Setting” feature.

    In this feature, users are allowed to set up to 10 holiday timers with each timer can last for duration of 99 days.

    During the duration of Holiday Timer set earlier, all fan coil units and chiller will automatically be turned Off.

    15 16

    HOLIDAY SETTING

  • Smart Manager controller will turn into low power mode during electricity power breakdown. It will operate based on the built in backup battery and only one timer and interrupt is active. CPU operation is Off and no display on LCD as well for energy saving purpose.

    LOW POWER MODE (CHILLER + FCU)

    User can also check the compressor run time of chiller in Smart Manager Controller. It will provide a guideline as well as posting a reminder for requirement of routine system service.

    RTC will always appear at the summary pages and the user is able to set the time and date.

    ACCUMULATIVE COMPRESSOR RUN TIME

    REAL TIME CLOCK (RTC)

    17 18

    To complement the new innovative Smart Manager range of air cooled chillers, Daikin is offering an extensive range of chilled water fan coil units that will meet most of indoor application requirements covering residential, light commercial and commercial.

    The aesthetically attractive decorative fan coil units such as Wall Mounted models, Ceiling Cassette and Ceiling Convertible are compact and ergonomic, the ranges can blend in easily to any interior designs whether it is residential houses, office, restaurant or shops.

    In addition, the Daikin chilled water fan coil units are designed with easy installation and easy servicing in mind. The fan coil units also include the microprocessor controller that has built in algorithm to control the operation of the fan coil unit as well as to provide protection to the unit.

  • Wall Mounted TypeAL

    › Stylish Front Panel › Comfortable Air Flow & Lower Sound Level› Indoor Quiet Mode› Turbo Mode› Uniform Air Distribution› Easy Maintenance› Wide Capacity Range› 5 Selectable Fan Speed

    › NIM-Able › Sleep Funtion For Cool & Heat Mode › Auto Restart With Last-State-Memory› Vlave & Vlaveless Control Options › Self Diagnosis Features› Compact & Easy To Use Wireless Remote Controller› Microprocessor Control› Automatic Air Swing

    Specification for Wall Mounted Type

    Btu/h 8300 9200 11300 15500 18000

    W 2430 2700 3310 4540 5280

    Btu/h 6300 6900 9000 11700 14000

    W 1850 2020 2640 3430 4100

    Btu/h 11000 12000 15000 20500 25000

    W 3220 3520 4400 6010 7330

    W 31 32 42 57 72

    A 0.20 0.20 0.21 0.30 0.34

    V/Ph/Hz

    CFM 260 280 370 510 620

    CFM 230 250 320 450 520

    CFM

    CFM

    200

    180

    220

    190

    260

    240

    390

    360

    460

    440

    USGPM 1.85 2.03 2.51 3.43 4.01

    litres/min 7.00 7.68 9.50 13.00 15.18

    kPa 34.0 24.0 31.0 30.0 36.0

    kPa 29.0 20.0 25.0 27.0 33.0

    kPa

    m/s 0.68 0.74 0.97 0.83 1.01

    dBA 34 / 29 / 25 / 24 35 / 30 / 25 / 24 42 / 39 / 32 / 29 42 / 38 / 34 / 32 46 / 42 / 39 / 37

    H X W X D mm

    H X W X D mm

    kg

    mm

    mm

    310 X 1065 X 224

    14

    1608

    288 X 800 X 206

    344 x 874 x 274

    9

    386 X 1136 X 314PACKING DIMENSION

    UNIT WEIGHT

    CONDENSATE DRAIN SIZE 19.05

    PIPE CONNECTION

    MEDIUM

    LOW

    QUIET

    NOMINAL WATER FLOW RATE

    12.70

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50˚C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L/Q)

    UNIT DIMENSION

    220-240 / 1 / 50

    REFRIGERANT TYPE N/A

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)

    OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    NOMINAL RUNNING CURRENT

    POWER SOURCE

    AIR FLOW

    HIGH

    FWW02L FWW03L FWW04L FWW05L FWW06LMODEL

    FWW-LWireless Remote Controller

    BRC52A Wired Remote Controller

    BRC51A (Option)

    ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    AL*

    Ceiling Cassette Compact Type (600x600)

    Specification for Ceiling Cassette Compact Type

    Btu/h 8500 14000 15500

    W 2490 4100 4540

    Btu/h 6500 10000 11500

    W 1910 2930 3370

    Btu/h 12000 16000 18000

    W 3520 4690 5280

    W 63 64 79

    A 0.28 0.28 0.35

    V/Ph/Hz

    CFM 380 400 440

    CFM 290 310 330

    CFM 230 220 280

    USGPM 2.03 3.43 3.57

    litres/min 7.68 12.98 13.51

    kPa 19.3 26.9 28.8

    kPa 16.8 23.9 26.5

    kPa

    m/s 0.75 0.76 0.83

    dBA 42 / 35 / 29 45 / 38 / 30 48 / 40 / 36

    H X W X D mm

    H X W X D mm

    kg 15 + 3 17 + 3 17 + 3

    mm

    mm 19.05

    19.05

    250 X 570 X 570 (295 X 640 X 640)

    220-240 / 1 / 50

    LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

    4 WAY AUTOMATIC LOUVER (UP & DOWN)

    N/A

    316 X 630 X 630 (126 X 700 X 726)

    1608

    CONDENSATE DRAIN SIZE

    PIPE CONNECTION

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50°C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L)

    UNIT DIMENSION - ( ) WITH PANEL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    AIR FLOW

    HIGH

    MEDIUM

    LOW

    POWER SOURCE

    NOMINAL RUNNING CURRENT

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE

    OPERATION

    NOMINAL WATER FLOW RATE

    REFRIGERANT TYPE

    PACKING DIMENSION - ( ) PANEL

    UNIT WEIGHT (UNIT + PANEL)

    › Compact Design › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › 4 Way Air Discharge & Air Swing› Valve Or Valveless Control Options› 3 Selectable Fan Speed› Microprocessor Control

    › Branch Duct Connection › Sleep Function For Cool & Heat Mode › Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Automatic Air Swing

    FWF02C FWF04C FWF05CMODEL

    FWF-C Wireless Remote Controller BRC52A

    Wired Remote ControllerBRC51A (Option)

    ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    19 20

  • Ceiling Cassette Type (900x900) With Brushless DC MotorAL

    *

    Specification for Ceiling Cassette Type

    QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH

    Btu/h 8200 11900 15900 20100 15200 19800 24700 30000 21000 26800 33100 40100

    W 2400 3500 4650 5900 4550 5800 7250 8800 6150 7850 9700 11750

    Btu/h 5800 8700 11700 15400 11000 14500 18500 21900 14600 18900 23800 28600

    W 1710 2540 3440 4510 3220 4260 5410 6430 4270 5540 6970 8370

    Btu/h 11300 15200 19800 24200 18400 23900 30400 38200 24100 31600 39100 46700

    W 3300 4450 5800 7100 5400 7000 8900 11200 7050 9250 11450 13700

    W 7 12 19 37 17 26 50 90 23 39 83 120

    A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95

    V/Ph/Hz

    CFM 220 350 470 620 420 560 720 890 510 680 870 1060

    Pa

    USGPM 1.84 2.68 3.56 4.52 3.41 4.44 5.55 6.74 4.71 6.01 7.43 9.00

    Litres/min 6.96 10.15 13.48 17.10 12.90 16.81 21.02 25.51 17.83 22.76 28.12 34.06

    kPa 5 10 15 24 7 9 14 20 15 22 30 41

    kPa 4 8 13 21 5 8 12 18 12 20 26 37

    kPa

    m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83

    dBA 16 23 31 37 31 37 42 47 34 41 46 51

    H X W X D mm

    H X W X D mm

    kg

    mm

    mm

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50˚C)

    FAN INPUT POWER

    NOMINAL RUNNING CURRENT

    POWER SOURCE

    REFRIGERANT TYPE

    CONTROLAIR DISCHARGE

    OPERATION

    AIR FLOW

    EXTERNAL STATIC PRESSURE (H/M/L)

    NOMINAL WATER FLOW RATE

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50˚C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL

    UNIT DIMENSION - ( ) WITH PANEL

    PACKING DIMENSION - ( ) PANEL

    UNIT WEIGHT

    CONDENSATE DRAIN SIZE

    PIPE CONNECTION

    220-240 / 1 / 50

    N/A

    4 WAY AUTOMATIC LOUVER (UP & DOWN)

    LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

    1608

    N/A

    265 X 820 X 820 (340 X 990 X 990)

    341 X 916 X 916 (125 X 1020 X 1020)

    300 X 820 X 820 (375 X 990 X 990)

    376 X 916 X 916 (125 X 1020 X 1020)

    26 + 4 28 + 4 32 + 4

    19.05

    19.05

    INDO

    OR

    UN

    IT

    FWKE05E FWKE08EMODEL

    FWKE11E

    FWKE-E Wireless Remote Controller BRC52A

    Wired Remote ControllerBRC51A (Option)

    Ceiling Cassette Type (900x900)AL

    *

    Specification for Ceiling Cassette Type

    Btu/h 21000 25000 30000 38000 43000

    W 6150 7330 8790 11140 12600

    Btu/h 16700 19200 22300 27400 31000

    W 4890 5630 6540 8030 9090

    Btu/h 28000 33600 38300 45500 52000

    W 8210 9850 11230 13340 15240

    W 95 126 167 186 227

    A 0.44 0.55 0.74 0.85 1.03

    V/Ph/Hz

    CFM 750 860 890 1000 1140

    CFM 620 700 720 840 1000

    CFM 480 540 570 680 840

    CFM 320 380 420 540 700

    USGPM 4.71 5.59 6.69 8.45 9.60

    litres/min 17.83 21.17 25.29 31.94 36.29

    kPa 20 37 22 44 53

    kPa 19 33 19 38 47

    kPa

    m/s 0.91 1.04 1.14 1.03 1.17

    dBA 42/38/32/23 46/42/35/27 48/43/38/30 50/47/43/33 52/49/45/39

    H X W X D mm

    H X W X D mm

    kg 26 + 4 26 + 4 28 + 4 32 + 4 32 + 4

    mm

    mm

    1600

    UNIT DIMENSION - ( ) WITH PANEL

    PACKING DIMENSION - ( ) PANEL

    19.05

    UNIT WEIGHT (UNIT + PANEL)

    CONDENSATE DRAIN SIZE

    19.05PIPE CONNECTION

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50°C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L/Q)

    LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

    AIR FLOW

    HIGH

    MEDIUM

    QUIET

    OPERATION

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    NOMINAL RUNNING CURRENT

    265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)

    341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)

    NOMINAL WATER FLOW RATE

    POWER SOURCE

    LOW

    220-240 / 1 / 50

    REFRIGERANT TYPE N/A

    › Modern & Elegant Panel› Optimum Air Discharge › Automatic Air Swing › 4 Way Air Discharge & Air Swing› Multi Comfort - 3 Air Swing Pattern Control › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › Valve Or Valveless Control Options› 4 Selectable Fan Speed

    › Branch Duct Connection› Low Height Design› Superior Sound Level › Sleep Function For Cool & Heat Mode › Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Self Diagnosis Features › Microprocessor Control

    FWK06E FWK08E FWK09E FWK11E FWK13EMODEL

    FWK-E Wireless Remote Controller BRC52A

    Wired Remote ControllerBRC51A (Option)

    NOTE :A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW :FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT FWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    21 22

    › Comfortable› Energy Saving› Low Noise› Low Maintenance & No Brush Sparking› Modulating Fan Speed Control› Modern & Elegant Panel› Optimum Air Discharge › Automatic Air Swing › 4 Way Air Discharge & Air Swing

    › Auto Restart With Last-State-Memory› NIM-Able › Choice Of Wired Or Withless Remote Controller› Self Diagnosis Features › Microprocessor Control› 4 Pipe System Model : FWKE-EH

    › Multi Comfort - 3 Air Swing Pattern Control › Fresh Air Intake › Built In High Head Drain Oump & Water Flow Switch › Valve Or Valveless Control Options› 4 Selectable Fan Speed› Branch Duct Connection› Low Height Design› Superior Stound Level › Sleep Function For Cool & Heat Mode

  • Specification for Ceiling Cassette Type (4 Pipe System)

    QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH

    Btu/h 6800 9600 12300 15000 13300 17100 20800 24600 17700 22200 26400 30700

    W 2000 2800 3600 4400 3900 5000 6100 7200 5200 6500 7750 9000

    Btu/h 5300 7600 10200 13100 9900 13000 16600 19600 13300 16700 20700 24500

    W 1560 2240 2990 3850 2910 3810 4850 5750 3890 4900 6060 7170

    Btu/h 12800 17200 21700 26100 21800 27300 32800 38200 31900 39100 46200 53400

    W 3750 5050 6350 7650 6400 8000 9600 11200 9350 11450 13550 15650

    W 7 12 19 37 17 26 50 90 23 39 83 120

    A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95

    V/Ph/Hz

    CFM 220 350 470 620 420 560 720 890 510 680 870 1060

    Pa

    USGPM 1.53 2.14 2.76 3.37 2.99 3.83 4.67 5.51 3.98 4.98 5.93 6.89

    Litres/min 5.80 8.12 10.44 12.75 11.31 14.49 17.68 20.87 15.07 18.84 22.47 26.09

    USGPM 1.44 1.93 2.43 2.93 2.45 3.06 3.68 4.29 3.58 4.38 5.19 5.99

    Litres/min 5.44 9.20 9.20 11.09 9.28 13.91 13.91 16.23 13.55 16.60 19.64 22.68

    kPa 5 9 13 18 6 10 15 19 12 19 24 32

    kPa 7 10 17 22 13 18 25 32 21 30 39 52

    kPa

    m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83

    dBA 16 23 31 37 31 37 42 47 34 41 46 51

    H X W X D mm

    H X W X D mm

    kg

    mm

    mm

    NOMINAL WATER FLOW RATE (COOLING)

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL

    UNIT DIMENSION - ( ) WITH PANEL

    PACKING DIMENSION - ( ) PANEL

    CONDENSATE DRAIN SIZE

    PIPE CONNECTION

    MODELFWKE05EH FWKE08EH

    POWER SOURCE

    REFRIGERANT TYPE

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE

    UNIT WEIGHT

    OPERATION

    AIR FLOW

    EXTERNAL STATIC PRESSURE (H/M/L)

    NOMINAL WATER FLOW RATE (HEATING)

    FWKE11EH

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY

    (ENTERING WATER TEMP. = 70˚C)

    FAN INPUT POWER

    NOMINAL RUNNING CURRENT

    NOMINAL COOLING CAPACITY

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 70˚C

    MAX. WORKING PRESSURE

    220-240 / 1 / 50

    N/A

    4 WAY AUTOMATIC LOUVER (UP & DOWN)

    LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL

    N/A

    1608

    265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)

    341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)

    26 + 4 28 + 4 32 + 4

    19.05

    19.05

    NOTE :A) BASED ON EUROVENT CONDITIONSB) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMPC) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW :FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT FWKE08/11EH MODEH - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    23

    FWE-E

    Wireless Remote ControllerBRC52A

    Wired Remote ControllerBRC51A

    Ceiling Convertible Type

    › Compact Design› Far Air Throw› Auto Air Swing› Service & Maintenance At Ease› Ceiling & Floor Installing Option› Versatile Installation› Room Temperature Sensing› 3 Selectable Fan Speed

    › Saranet Filter› Sleep Function For Cool And Heat Mode› Auto Restart With Last-State-Memory› Valve Or Valveless Control Options› Self Diagnosis Features› NIM-Able› Choices Of Wired Or Wireless Remote Controller› Microprocessor Control

    Specification for Ceiling Convertible Type

    FWE05E FWE06E FWE07E FWE08E FWE10E FWE12E

    Btu/h 15500 20300 21000

    W 4540 5950 6150

    24800

    7270

    34500

    10110

    46300

    13570

    51600

    15120

    33700

    9880

    40000

    11720

    Btu/h 12700 15400 16150

    W 3720 4510 4730

    Btu/h 19500 25000 28000

    W 5720 7330 8210

    W 86 135 160

    A 0.38 0.67 0.79

    V/Ph/Hz

    CFM 520 580 640

    CFM 460 530 560

    CFM 406 490 460

    USGPM 3.43 4.49 4.67

    Litres/min 13 17 17.68

    kPa 27 48 57

    kPa 24 42 50

    kPa

    m/s 0.87 1.01 1.08

    dBA 45 / 38 / 36 46 / 43 / 39 49 / 46 / 41

    H X W X D mm

    H X W X D mm

    kg

    mm

    mm

    NOMINAL TOTAL INPUT POWER

    MODEL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50 ⁰C)

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)

    OPERATION LCD WIRELESS MICRO-COMPUTERREMOTE CONTROL

    AIR FLOW

    HIGH

    MEDIUM

    LOW

    UNIT WEIGHT 27

    NOMINAL WATER FLOW RATE

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50⁰C

    MAX. WORKING PRESSURE

    NOMINAL RUNNING CURRENT

    POWER SOURCE 220-240 / 1 / 50

    REFRIGERANT TYPE N/A

    1608

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L)

    UNIT DIMENSION 212 X 1090 X 630

    PACKING DIMENSION 297 X 1197 X 740

    CONDENSATE DRAIN SIZE 19.05

    PIPE CONNECTION 12.7

    COMI

    NG SO

    ON

    COMING SOON

    ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    AL

    *

    24

  • AL*

    Ceiling Concealed Type

    › Excellent Air Distribution› Compaot Design› High Capacity Range› High External Static Pressure Range› Double Protection Drainage › Easy To Service › Left/Right Piping Option› Wide Capacity Range

    › Choices Of With Or Without Wired Handset› 4 Useable Fan Speed› Self Diagnosis Features› NIM-Able› Auto Restart With Last-State-Memory› Valve Or Valveless Control Option› 4 Speed Fan Motor For Application Flexibility

    Specification for Ceiling Concealed Type

    FWC03C FWC04C FWC06C FWC07C

    Btu/h 9900 11600 18000 22500

    W 2900 3400 5280 6590

    Btu/h 7000 8120 12600 15750

    W 2050 2380 3690 4620

    Btu/h 11500 15000 23000 29000

    W 3370 4400 6740 8500

    W 89 140 168 182

    A 0.40 0.65 0.77 0.86

    V/Ph/Hz

    CFM 300 510 700 730

    CFM 285 490 675 660

    CFM 260 400 640 580

    Pa 49 / 44 / 36 49 / 42 / 28 49 / 45 / 41 49 / 43 / 30

    USGPM 2.20 2.60 4.05 5.06

    litres/min 8.33 9.84 15.33 19.15

    kPa 10.5 24.0 20.1 32.4

    kPa 8.8 20.3 17.0 27.6

    kPa

    m/s 1.29 1.72 1.83 1.72

    dBA 36 / 35 / 33 40 / 38 / 33 42 / 41 / 40 41 / 40 / 36

    H X W X D mm 267 x 702 x 351 267 x 842 x 351 267 x 1002 x 351 267 x 1137 x 351

    H X W X D mm 376 x 951 x 541 376 x 1091 x 541 376 x 1251 x 541 376 x 1386 x 541

    kg 18 22 24 26

    mm

    mmPIPE CONNECTION

    1608

    19.05

    PACKING DIMENSION

    UNIT WEIGHT

    CONDENSATE DRAIN SIZE 19.05

    HEAD LOSS (HEATING) : 50°C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L)

    UNIT DIMENSION

    HIGH

    MEDIUM

    LOW

    NOMINAL WATER FLOW RATE

    EXTERNAL STATIC PRESSURE

    HEAD LOSS (COOLING)

    REFRIGERANT TYPE N/A

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE DUCTED

    OPERATION WIRED MICRO-COMPUTER REMOTE CONTROL

    AIR FLOW

    POWER SOURCE 220-240 / 1 / 50

    MODEL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    NOMINAL RUNNING CURRENT

    Specification for Ceiling Concealed Type

    FWC09C FWC11C FWC12C FWC14C FWC16C

    Btu/h 24800 38000 37000 44700 51800

    W 7270 11140 10840 13100 15180

    Btu/h 19700 29800 29300 35100 40900

    W 5770 8730 8590 10290 11990

    Btu/h 32800 49200 48000 54900 65300

    W 9610 14420 14070 16090 19140

    W 345 504 442 427 531

    A 1.50 2.28 1.93 1.86 2.32

    V/Ph/Hz

    CFM 830 1250 1240 1340 1550

    CFM 760 1130 1100 1220 1400

    CFM 710 1040 1020 1190 1300

    Pa 167 / 128 / 88 118 / 108 / 88 128 / 88 / 39 157 / 137 / 108 157 / 137 / 98

    USGPM 5.55 8.59 8.28 10.04 11.62

    litres/min 21.01 32.51 31.34 38.00 43.98

    kPa 14.0 39.0 23.0 38.0 51.0

    kPa 11.0 37.0 19.0 33.0 48.0

    kPa

    m/s 1.40 1.74 1.83 1.54 1.52

    dBA 46 / 42 / 38 51 / 48 / 45 49 / 45 / 41 52 / 50 / 47 53 / 50 / 47

    H X W X D mm 384 x 917 x 462 316 x 1225 x 559 384 x 1003 x 462 384 x 1287 x 462 384 x 1487 x 462

    H X W X D mm 415 x 1126 x 631 355 x 1461 x 727 415 x 1245 x 631 415 x 1497 x 631 415 x 1701 x 631

    kg 42 47 44 50 56

    mm

    mm

    19.05

    1608

    19.05PIPE CONNECTION

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL (H/M/L)

    UNIT DIMENSION

    PACKING DIMENSION

    UNIT WEIGHT

    CONDENSATE DRAIN SIZE

    WIRED MICRO-COMPUTER REMOTE CONTROL

    HIGH

    MEDIUM

    LOW

    NOMINAL WATER FLOW RATE

    HEAD LOSS (COOLING)

    AIR FLOW

    220-240 / 1 / 50

    REFRIGERANT TYPE N/A

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE DUCTED

    OPERATION

    MODEL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY (ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    NOMINAL RUNNING CURRENT

    EXTERNAL STATIC PRESSURE

    POWER SOURCE

    HEAD LOSS (HEATING) : 50°C

    FWC-C Wired Remote ControllerBRC51A

    ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    25 26

  • AL

    * *

    Ducted Blower Type

    Specification for Ducted Blower Type

    FUD20B FUD25B FUD30B FUD40B

    Btu/h 75600 95000 125000 150000

    W 22160 27840 36640 43960

    Btu/h 53700 69400 90000 106500

    W 15740 20340 26380 31210

    Btu/h 78000 97500 138000 170000

    W 22860 28580 40450 49820

    W 760 1800 1620 1910

    A 3.49 7.84 3.33 4.03

    V/Ph/Hz

    CFM 2500 3200 4200 4600

    CFM 2100 3000 N/A N/A

    CFM 1750 2800 N/A N/A

    Pa 100 / 72 / 50 100 / 80 / 60 230 230

    USGPM 16.90 21.10 27.70 33.30

    litres/min 64.00 80.00 105.00 126.00

    kPa 34.5 42.0 48.8 53.3

    kPa 32.9 27.4 31.5 63.2

    kPa

    m/s 2.19 2.80 1.96 2.15

    dBA 50/46/42 54/52/50 58 58

    H X W X D mm

    H X W X D mm

    kg 92 102 176 189

    mm

    mm

    380-415 / 3 / 50220-240 / 1 / 50

    1608

    PIPE CONNECTION

    UNIT WEIGHT

    CONDENSATE DRAIN SIZE 19.05

    28.58

    762 x 1605 x 880

    885 x 1540 x 850

    1154 x 1787 x 1188

    HEAD LOSS (COOLING)

    HEAD LOSS (HEATING) : 50°C

    MAX. WORKING PRESSURE

    SURFACE AIR VELOCITY

    SOUND PRESSURE LEVEL

    UNIT DIMENSION

    PACKING DIMENSION

    HIGH

    MEDIUM

    LOW

    NOMINAL WATER FLOW RATE

    EXTERNAL STATIC PRESSURE

    572 x 1402 x 605

    N/A

    INDO

    OR

    UN

    IT

    CONTROLAIR DISCHARGE DUCTED

    OPERATION WITHOUT CONTROLLER

    AIR FLOW

    POWER SOURCE

    REFRIGERANT TYPE

    MODEL

    NOMINAL COOLING CAPACITY

    NOMINAL SENSIBLE COOLING CAPACITY

    NOMINAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

    NOMINAL TOTAL INPUT POWER

    NOMINAL RUNNING CURRENT

    FUD20/25B FUD40/50B

    › Excellent Air Distribution› 4 Useable Fan Speed› Easy To Service› Fire-Resistant Polysthylene Insulation› Left/Right Piping Option› Cabinet Construction› High External Static Pressure Range› ChangeableDrive Package

    › Convertible Air Throw Direction› High CFM Range› Wide Capacity Range› 4 Useable Fan Speed Is Applicable For FUD20/25B› Changeable Drive Package Is Applicable For FUD30/40B› Flexibility In Adjusting Air Flow And External Static For FUD30/40B› Convertible Air Throw Direction Is Applicable For FUD30/40B

    ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

    27°c DB / 19°c WB 20°c DB

    7°c50°c (2 PIPES SYSTEM)

    12°c

    70°c (4 PIPES SYSTEM)

    ENTERING AIR TEMPRATURE

    MODE COOLING HEATING

    60°c (4 PIPES SYSTEM)

    ENTERING WATER TEMPRATURE

    LEAVING WATER TEMPRATURE

    27

  • Features:• Cool/Heat/Fan/Dry/Auto mode• Auto/High/Med/Low fan speed• Temperature operate in ºC and ºF• Turbo and Quiet Function• Sleep function• Swing function• Real time clock and day display• 7-days programmable timer• Error indicator• Key lock and fan lock features• Batteries backup and retain setting during power failure• Last state memory (Memory backup setting from main board)• Delay Timer (1 or 2 hours)• Interaction with Wireless Handset (BRC52A61/BRC52A62)

    1. Vertical Automatic Air Swing2. Selectable Mode: Auto Mode, Cooling , Heating, Dry, Fan3. Turbo Function4. Quiet Function5. ON Timer Setting6. Real Time Clock7. Transmission Source8. “Glow in the dark” ON/OFF Button9. Fan Speed Selection: Low, Med, High, Auto10. Temperature Setting: Up & Down11. Sleep Mode Function12. OFF Timer Setting

    1

    7

    8

    9

    101112

    234

    5

    6

    BRC52A61 – Heatpump with auto modeBRC52A62 – Cooling onlyBRC52A63 - Heatpump

    BRC51A61 – Heatpump with auto modeBRC51A62 – Cooling only

    ControllerBRC52A

    BRC51A

    28

  • With Wireless Remote Controller

    With Wired Remote Controller

    CONTROLLER

    Power from Indoor

    Power from Outdoor

    POWER SUPPLY

    Selectable Fan Speed - Di�erent fan speed isavailable for comfort selection

    Belt Driven Evaporator Motor

    Automatic Vertical Swing - Automatic movementof air discharge louver for uniform air distribution

    Manual Horizontal Air Flow - Adjustable horizontaldischarge grille for desired air �ow direction

    AIR FLOW

    4 Way Air Discharge

    Standard FeaturesCOMFORT

    Dry Mode - Keeping the room dehumidi�ed,while maintaining room temperature

    Turbo Mode - Rapid cooling/heating withhighest fan speed for immediate comfort

    Quiet Mode - E�ective cooling withlower noise level

    Auto Mode - Auto switching between cooling andheating mode depending on room and set temperature

    Sleep Mode

    FIN TYPE

    Bare Aluminium FinAL

    Anti Corrosion Hydrophilic Gold FinGOLD

    Ionizer

    IAQWashable Saranet Filter - Removal of airborne dustparticles through saranet �lter ensures cleaner airsupply

    Titanium Apatite Photocatalytic Air-Purifying Filter

    Bio Antibody Filter

    Variable Pitch Pully Drive Package

    29

  • NIM

    Main Board Controllers And Display Control PanelNIM must be used in conjunction with:• Fan coil units • BRC51A or BRC52A

    Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits:

    Benefits• More convenience. No more individually controlling air conditioning units• Quicker and easier zone control from the master control unit• Better control of air conditioning systems operating conditionsNIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.

    Every master unit will have a group address so that every slave can only response to their respective master. Each slave unit must have a unique address so that it can be addressed independently of other nodes.

    The master unit will be operating in conjunction with a control panel. Any settings done via the control panel connected to the master will overwrite the settings of its slave units.

    Slave unit can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master.

    Basic Features• DIP switch setting for Group & Unit address.• Master or slave system configuration.• Automatic detection of control panel existence.• Error type and unit ID indication through display control panel.

    • Maximum point to point communication bus up to 1000m.• A single master unit can control up to 15 slave units in each group.• Each slave unit will sense their individual local temperature.• Unit address range from 0 to 15 (0000-1111).

    The NIM System Consists Of• Main Board controller • Display control panel • NIM controller • Communications bus

    Intelligent Control Series

    Network Control NIM

    (up to total of16 FCUs)

    Slave(s)Slave(s)SlaveMaster

    Connection

    ConnectionThe communication bus must be connected serially to the adjacent NIM. (Daisy chain connection). The same polarity has to be connected between the NIMs (A to A, B to B).

    Communication BusA 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.

    Supported Configuration

    BRC51A

    BRC52A

    Master Slave

    G-Way

    First NIM to the furthestconnected NIM 1000

    10

    10

    Connection

    NIM to Main Board

    NIM to Wired Controller

    Recommended Maximum Cable Length (m)

    G-Way

    To MainBoard

    To Wired Control Panel

    CN2

    CN1 RELAY 1

    RELAY 2

    DIP SwitchTerminal

    Blocks

    NO

    NO

    COM

    COM

    Dry ContactOutput 1

    Dry ContactInput

    Dry ContactSwitch

    Unit On/OffIndicator

    Unit ErrorIndicator

    BMSG-Way Controller

    Dry ContactOutput 2

    1000 m

    Types of Operation DSW2 Setting

    Control & Monitor (Ext. Switch Closed = ON A/C) 0000

    0010

    0001

    Control & Monitor (Ext. Switch Open = ON A/C)

    Monitoring only

    Function• Gateway between DX fan coil unit and basic Building Management System (BMS).

    Note: • Remote (On/Off) control of air conditioner via BMS.• Unit error indication via BMS and BRC51A controller.• Unit operation status monitoring via BMS.• Maximum point to point communication bus between air conditioner and BMS of up to 1000m.• DIP switch setting for control or monitoring function.

    DSW2 Setting

    30 31

  • • Laboratory• Railway Switching Center• Room with Critical Electronics Equipments

    • S-NIM controller• Communication Bus

    S-NIM

    Master Unit

    Slave Unit

    Typical connection structure for S-NIM

    Main Board Main Board

    Control Panel

    The S-NIM System Consists Of• Main Board controller• BRC51A

    Communication BusA 2-way twisted pair cable is used as the communication bus.Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameterof 0.5mm to 1.0mm.

    S-NIM Controller Application• Server Room• Telecommunication Tower• Livestock Breeding Farm• Warehouse

    S-NIM For Timer Switchover Control

    Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment.

    S-NIM works in a master & slave system, operating at alternate sequence of preset hours. Whenever the operating unit is at fault, the standby unit will automatically takes over.

    Features• Auto restart feature with last state settings.• 2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12 hours).• System controlled by a single BRC51A controller.• When the operating unit is at fault, the standby unit automatically takes over.• Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)• During system OFF mode, running timer will stop. It resumes when changing to ON mode.• Preset operation hours can be set via DIP Switch.* The air conditioning unit connected to the wired controller is always the master unit.

    S-NIMS-NIM

    32

    0. pgCover Chilled Water System1. Contentsp. 1 & 2 Applicationp. 3 & 4 Applicationp. 5 & 6 Features 1p. 7 & 8 Features 2p. 9 & 10 SPEC 1p. 11 & 12 SPEC 2p. 13 & 14 Solution 1p. 15 & 16 Solution 2p. 17 & 18 Solution 3p. 19 & 20 FCU spec 1p. 21 & 22 FCU spec 2p. 23 & 24 FCU specp. 25 & 26 FCU specp. 27 FCU specp. 28 controllerp. 29 Std featuresp. 30 & 31 NIMp. 32 NIM