147147 Self-Contained emergenCy lighting SyStem
Mains On
Charging
Battery Fault
Self-testing
Self-test Fault
AUTOMATICTEST UNIT
GREEN LED
YELLOW LED
RED LED
CC-ATS
NEUTRAL
I/P 220V 50Hz
Mains
Lamp
12V 50W12V 50W METAL HALITEWith Timer
LIVE
A
L
L
N
N
II I
NEUTRAL
Battery Kit Luminaire
CRYSTALITE
ELECTRONICBALLAST
Non-maintained Type後備式
NEUTRAL
CRYSTALITEINVERTER
Maintained Type 長明式
NEUTRAL
CRYSTALITEINVERTER
ELECTRONICBALLAST
CRYSTALITEINVERTER
BALLAST
NEUTRAL
Electronic Ballast Electromagnetic Ballast
Fig. 1) For Kitemark (200, 300, 500) series, T8 & T5 fluorescent tube, PL-4P & 2D 28W (008 Casing)
Fig. 4) For PL-2P
Fig. 6) For 12V 50W + Timer Fig. 7) 008 Fluorescent + CC-ATS
Fig. 5) One Electronic Ballast for two fluorescent tube
1
2
3
4
5
6
7
8
9
10
13
11
12
A
L
N
BATTERY
LIVE SWITCH
LIVE
NEUTRAL
LED
STARTER
CRYSTALITEINVERTER
Fig. 2) For Old type of T8 fluorescent tube (004 Casing)
A
A1
1
2
3
4
5
6
7
8
9
10
13
11
12
14
LN
A
L
N
BATTERY+
LIVE SWITCH
LIVE
NEUTRAL
4
21
3
15
16
LED
CRYSTALITEINVERTER
Fig. 3) For slim size of T8 & T5 fluorescent tube (009 Casing)
Appendix C: Connection Diagram
12
11
10
9
8
7
1
2
3
4
5
6
LEDBATTERY
LIVE SWITCH
LIVE
NEUTRAL
A
L
N
12
11
PL-C 2PTUBE
CRYSTALITEINVERTER
ELECTRONIC BALLAST
LIVE SWITCH
LIVE
NEUTRAL
LED BATTERY
7654321
LN
7654321
LN
8
7
D2
D1
9
10
11
12
13
14
5
6
4
3
2
1
A1
ATUBE
TUBE
LA
N
CRYSTALITEINVERTER
Remark:Some of the electronic Ballast do not contain terminal 4
148148SELF-CONTAINED EMERGENCY LIGHTING SYSTEM
Fig. 12) CC-M-LED DK Series (for high power LEDLuminaire which contain 1-10V Dimmer)
Fig. 14) LED Exit Sign with Sync. function
Fig. 13) CC-M-LED with remote LED Driverwhich contain Dimmer
Fig. 10) CC-M-LED & T-LED Series
Fig. 8) CC-LED & R24 Series
Fig. 11) CC-M-LED & T-LED + CC-ATS
Fig. 9) CC-LED & R24 Series + CC-ATS
Appendix C: Connection Diagram
NL
A
L
N
+
LIVE SWITCH
LIVE
NEUTRAL
-+
1
2
3
4
5
6
9
7
8
10
11
12
CRYSTALITECONVERTER
LEDDRIVER
LED LAMPPRI
220V INSECOUT
+
-
A
A1
Indicator
NEUTRAL
AUTOMATICTEST UNIT
GREEN LED
YELLOWLED
RED LED
CC-ATS
LEDDRIVER
LEDLamp
CRYSTALITECONVERTER
CRYSTALITEINVERTER
161514131211109
12345678
TRANSFORMER
TEST BUTTONINDICATOR
BATTERY
N
L
A
ORANGEORANGE
BLACK GREENYELLOW
NEUTRAL
220V 50HzLUMINAIRES
N/o
L/o
NEUTRAL
AUTOMATICTEST UNIT
GREEN LED
YELLOW LED
RED LED
CC-ATS
1413
1516
O
220V 50HzLUMINAIRES
N/o
L/o
TRANSFORMERORANGEORANGE
BLACK GREENYELLOW
CRYSTALITEINVERTER
TEST BUTTON
CRYSTALITEINVERTER
20191817161514131211109
12345678
TRANSFORMER
TEST BUTTONINDICATOR
BATTERY
DIMMER
N
L
A
ORANGEORANGE
BLACK GREENYELLOW
NEUTRAL
220V 50HzLUMINAIRESwith 1-10V
Dimmer
N/o
L/o
DIMMER
IN
OUT+_
+_
Dimmer InputD-
D+
Do-
Do+ DimmerOutput
L
N
CRYSTALITEINVERTER
161514131211109
12345678
TRANSFORMER
TEST BUTTONINDICATOR
BATTERY
N
L
A
ORANGEORANGE
BLACK GREENYELLOW
NEUTRAL
LUMINAIRES
D-
D+Dimmer Input
LED DRIVER+
_
+
_Dimmer
220V AC Relay
L
N
Sync. Signal Generator Exit Sign A
NEUTRAL
LIVEIndicator
12
11
10
9
8
7
1
2
3
4
5
6
L
–
+N
Fire Signal Input
NEUTRAL
LIVE
12
11
10
9
8
7
1
2
3
4
5
6
CRYSTALITE
L
–
+N
Option:
3) 220V A.C. Input Signal
1) Dry Contact (Short Circuit)2) 24V D.C. Input Signal
LED Bar
Battery
Indicator
Battery
Test Button
+) Pairs of Orange and Brown Cables
-) Pairs of Green and Blue Cables
Recommation: Use Category 5e UTP Cable
Max. Length = 500 metersMax. Numbers of Exit Sign for each signal generator = 100pcs
+–
For Exit Sign B to N–
+Sync. Signal Output
CONVERTER
CRYSTALITESYNC. SIGNALGENERATOR