4
PUSH BUTTON DC 12V~24V RED SL-100 READER ORANGE Please switch on the appliance again to validate any adjustment of DIP switch value 0 SEC. 2.5 SEC. 5 SEC. 9 SEC. Setting door lock delay timer : BROWN Page 1 APEB100A ( 5 PIN ) APEB100B ( 6 PIN ) Brown - GND Brown - GND Red +DC12V Red +DC12V Orange Push Button Orange Push Button Yellow Door Position Sensor(N.C.) Yellow Door Position Sensor(N.C.) Green Door Position Sensor(COM.) Green Door Position Sensor(COM.) Bule Door Position Sensor(N.O.) Power Supply 1A@DC12V Current Operation Current 900mA, Holding Current 360mA Operation Delay Time 0sec. 2.5sec. 5sec. 9sec. Signal Output Door Sensor(250mA) Face Plate 200 (L) X 32 (W) X 40 (H) mm Strike Plate 90 (L) X 26 (W) X 2.5 (H) mm Bolt 16mm (Throw) X 15.5mm (Diameter) Safety Measures (1)Fail-safe Type(Power to lock). (2)Built-in photo couplers door open push button input contact. Door will lock again automatically when door is not open within 5 seconds. Connections Model Color Model Color Wiring Diagram Specifications APEB100A Fail- safe Type Deadbolt Lock Installation Manual VER 15.02.03

Upload: hoangkiet

Post on 03-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

PUSH BUTTON

DC 12V~24V

RED

SL-100

READER

ORANGE

� Please switch on the appliance again to validate any adjustment of DIP switch value

0 SEC.

2.5 SEC.

5 SEC.

9 SEC.

Setting door lock delay timer :

BROWN

Page 1

APEB100A ( 5 PIN ) APEB100B ( 6 PIN )

Brown - GND Brown - GND

Red +DC12V Red +DC12V

Orange Push Button Orange Push Button

Yellow Door Position Sensor(N.C.) Yellow Door Position Sensor(N.C.)

Green Door Position Sensor(COM.) Green Door Position Sensor(COM.)

Bule Door Position Sensor(N.O.)

Power Supply 1A@DC12V

Current Operation Current 900mA, Holding Current 360mA

Operation Delay Time 0sec. 2.5sec. 5sec. 9sec.

Signal Output Door Sensor(250mA)

Face Plate 200 (L) X 32 (W) X 40 (H) mm

Strike Plate 90 (L) X 26 (W) X 2.5 (H) mm

Bolt 16mm (Throw) X 15.5mm (Diameter)

Safety Measures

(1)Fail-safe Type(Power to lock).(2)Built-in photo couplers door open push button input contact. Door will lock again automatically when door is not open within 5 seconds.

� Connections Model

Color Model

Color

� Wiring Diagram

� Specifications

APEB100A Fail - safe Type Deadbolt Lock Installation Manual

VER 15.02.03

※ Accessories:

X 1 Lock body X 1 Strike plate

X 2 Shims(small)

For strike plate X 2 Shims (Large) for

Lock body SCREWS:

5/6-PIN Connector

Lock body

templates

Faceplate

X 8 Small wood screws for strike

plate( 4 x 8 mm)

X 4 Large metal screws for lock

body and shims( 5 x 8 mm)

Strike plate template

X4 Small metal screws for strike plate

and shims( 4 x 15 mm)

X 2 Large wood screws for lock

body( 5 x 26 mm)

Door Lock

Delay Timer

Start

Stand-by Door Close

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

65 60 55

40

50 45

35 30 25

70

Current

(mA)

Time (sec.)

Time (min.)

Temperature

(℃)

Door close

※ Current and Temperature Chart: (Measurement:Power Supply DC-12V, Room temperature 25℃, Humidity 60% Rh)

Page 2

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

900 800 700

400

600 500

300 200 100

~

~

1000

VER 15.02.03

~

~

※ Installation:

For double doors For single doors For single doors

Important-For vertical

mounting, wires must come

out the top of the unit.

Instruction:

Diagram 1: Dimensions

Diagram 2: For double door mounting

Diagram 3: For single door mounting

Diagram 4: For vertical mounting

Diagram 1

Diagram 2 Diagram 3 Diagram 4

Page 3 VER 15.02.03

Strike plate

Faceplate

20mm

※ Installation:

Please make sure the correct

direction of the shims when mounted

For hollow metal doors: For wood doors:

45mm

Drill hole for deadbolt

(If wood door)

Drill hole for magnet

(if wood door)

Door

◆ The lock is hot?

The operating temperature of the lock is normally within 55℃.

◆ No operation after installation?

1.Please check power supply. 2.Please check if the direction of

the template is being installed correctlly 3.Please check the

connection points(N.O or N.C)

◆ Lock will open when force is applied on the reader (eg. Hitting

hard or vibrating the reader).?

1.Please check all the connections .

2.Reader's N.C points might strike immediately when force is

being applied on it this eventually causes the fail-safe type of lock

to open when sudden power cut occured. Please refer to page 1

for wiring to prevent such case happen.

Question & Answer

Page 4 VER 15.02.03