“9000” - laser lightinglaserlighting.com.au/web/indoor/novalux/profile/9000.pdf · 2020. 4....

16
“9000” 82 The system 9000 performs an elegant solu- tion to different applica- tions. It is manufactured with a convenient and linear design allowing the flexibility and versatility of use. The ceiling or suspension fittings may be installed as modular system or as single point of illumination. The antiglare louvres are designed for the needs of Banks, Insurances and other offices, where the monitors are frequently used. The lamellar diffu- sers are developed for an efficient distribution of light where is requested an accurate and comforta- ble illumination as shops or showrooms. Materials Body in zinc coated steel White or grey. Base in white zinc coated steel. Ending parts ABS same colour of the body. Reflector in white zinc coated steel. Low luminance alumi- nium louvre (included) or modular opal lamellar screens (separately sup- plied). Included accessories: for continuous line mounting. Fluorescent lamps are not included. Wiring Starter wiring 230V-50Hz with power factor correc- tion, electrical compo- nents with ENEC approval. Rigid cable H05V2-U section 0,75 mm 2 (CEI 20-20). Socket terminal 2P+T (section max 2,5 mm 2 ) on both sides with phase and neutral line connected with coloured cables H05V2-U, section 1,5 mm 2 . Wiring on request with electronic or dimmable ballast and/or with emer- gency light. In accordance with stan- dard IEC 598, CEI EN 60598-1 CEI 34-21) Emergency wiring in accordance with standard CEI EN 60598-2-22 (CEI 34-22). “9000” system

Upload: others

Post on 13-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

82

The system 9000performs an elegant solu-tion to different applica-tions. It is manufacturedwith a convenient andlinear design allowing theflexibility and versatility ofuse. The ceiling orsuspension fittings maybe installed as modularsystem or as single pointof illumination.The antiglare louvres aredesigned for the needs ofBanks, Insurances andother offices, where themonitors are frequentlyused. The lamellar diffu-

sers are developed for anefficient distribution oflight where is requestedan accurate and comforta-ble illumination as shopsor showrooms.

MaterialsBody in zinc coated steelWhite or grey.Base in white zinc coatedsteel.Ending parts ABS samecolour of the body.Reflector in white zinccoated steel.Low luminance alumi-nium louvre (included)

or modular opal lamellarscreens (separately sup-plied).Included accessories: forcontinuous line mounting.Fluorescent lamps are notincluded.

WiringStarter wiring 230V-50Hzwith power factor correc-tion, electrical compo-nents with ENEC approval.Rigid cable H05V2-U section0,75 mm2 (CEI 20-20).Socket terminal 2P+T(section max 2,5 mm2)on both sides with

phase and neutral lineconnected with colouredcables H05V2-U, section1,5 mm2.Wiring on request withelectronic or dimmableballast and/or with emer-gency light.In accordance with stan-dard IEC 598, CEI EN60598-1 CEI 34-21)Emergency wiring inaccordance with standardCEI EN 60598-2-22(CEI 34-22).

“9000” system

Page 2: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

83

Page 3: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

84

A9011BI

A9011 BI•GR 1x58 1595 n. 5 A9008A9013 BI•GR 1x36 1295 n. 4 A9008A9015 BI•GR 1x18 685 n. 2 A9008

A9111 BI•GR 2x58 1595 n. 5 A9008A9113 BI•GR 2x36 1295 n. 4 A9008A9115 BI•GR 2x18 685 n. 2 A9008

BI

GR

L

90

185

pag. 338CL I IP20 FD

G13

Code Lamps L Completion screenWatt mm

Code Lamps L Completion screenWatt mm

Single lamp light fittings direct light forT8 lamps for lamellar screens.

Modular screens (separately supplied)in opal lamellar.

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Without diffuser

Page 4: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

85

A9311GR

A9311 BI•GR 3x58 1595 n. 5 A9108A9313 BI•GR 3x36 1295 n. 4 A9108A9315 BI•GR 3x18 685 n. 2 A9108

BI

GR

L

90

300

pag. 339CL I IP20 FD

G13

Without diffuser

Code Lamps L Completion screenWatt mm

Doule lamp light fittings direct light forT8 lamps for lamellar screens.

Modular screens (separately supplied)in opal lamellar.

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Page 5: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

86

309

135

309

250

“9000” Screens

Code Indications

Opal Lamellar Screen.Modular opal lamellar screen to be snappedonto the base.

Code Indications

Opal Lamellar Screen.Modular opal lamellar screen to be snappedonto the base.

A9008 for 9000 system single or double

A9108 for 9000 system with 3 lamps

Page 6: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

87

A9591BI

A9591 BI•GR 1x58 1595A9593 BI•GR 1x36 1295A9595 BI•GR 1x18 685

A9511 BI•GR 1x58 1595A9513 BI•GR 1x36 1295A9515 BI•GR 1x18 685

BI

GR90

185 L

pag. 339-340CL I IP20 FD

G13

Code Lamps L high gloss lowWatt mm luminance louvre

Code Lamps LWatt mm matt low luminance louvre

Single lamp light fitting direct light forT8 lamps, gloss or matt dark light lou-vre.

Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Page 7: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

88

A9491GR

A9491 BI•GR 1x58 1595A9493 BI•GR 1x36 1295A9495 BI•GR 1x18 685

A9411 BI•GR 1x58 1595A9413 BI•GR 1x36 1295A9415 BI•GR 1x18 685

BI

GR90

185 L

pag. 339CL I IP20 FD

G13

Code Lamps L high gloss lowWatt mm luminance louvre

Code Lamps LWatt mm matt low luminance louvre

Single lamp light fitting direct/indirectlight for T8 lamps, gloss or matt lowluminance louvre.

Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

luce diretta/indiretta

Page 8: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

89

A9691BI

A9691 BI•GR 2x58 1595A9693 BI•GR 2x36 1295A9695 BI•GR 2x18 685

A9611 BI•GR 2x58 1595A9613 BI•GR 2x36 1295A9615 BI•GR 2x18 685

BI

GR

90

300 L

pag. 340CL I IP20 FD

G13

Code Lamps L high gloss lowWatt mm luminance louvre

Code Lamps LWatt mm matt low luminance louvre

Double lamp light fitting direct lightfor T8 lamps, gloss or matt low lumi-nance louvre.

Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Page 9: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

90

Page 10: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

91

Page 11: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

92

A9791GR

A9791 BI•GR 2x58 1595A9793 BI•GR 2x36 1295A9795 BI•GR 2x18 685

A9711 BI•GR 2x58 1595A9713 BI•GR 2x36 1295A9715 BI•GR 2x18 685

BI

GR

90

300 L

pag. 340-341CL I IP20 FD

G13

luce diretta/indiretta

Code Lamps L high gloss lowWatt mm luminance louvre

Code Lamps LWatt mm matt low luminance louvre

Double lamp light fittingdirect/indirect light for T8 lamps, glossor matt low luminance louvre.

Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Page 12: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

93

A9021BI

A9021 BI•GR 1595A9023 BI•GR 1295A9025 BI•GR 685

A9321GR

185

L90

300L

90

BI

GR

BI

GR

A9321 BI•GR 1595A9323 BI•GR 1295A9325 BI•GR 685

“9000” Accessories

Code Lmm

Colours

Colours

Empty module.Spacing unit, white or grey.

Code Lmm

Empty module.Spacing unit, white or grey.

Page 13: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

94

A9000 1200A9000/M3 3000

LL

76 185

193 300

A9001 1200 3x1,5A9001 2A 1200 4x1,5A9001/M3 3000 3x1,5A9001/M3 2A 3000 4x1,5

A9002

A9003

“9000” Accessories

Code Lmm

Suspension.2 steel cables.

Code L Wire of alim.mm

Cable suspension. 2 steel cables; 1 supply cable.

Code

Accessory for ceiling fixing.Accessories for ceiling fixing (mm. 185) twopieces in one box.

Code

Accessory for ceiling fixing.Accessories for ceiling fixing (mm. 300) twopieces in one box.

Page 14: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

95

L 127

A9401 1535 for art. A9411..A9403 1235 for art. A9413..A9405 625 for art. A9415..

242L

BI

GR

BI

GR

A9701 1535 for art. A9711..A9703 1235 for art. A9713..A9705 625 for art. A9715..

A9005 BI•GR

A9006 BI•GR

“9000” Accessories

Code L Indicationsmm

Colours

Colours

Dust protection for dark light fittingsdirect/indirect light versions.Transparent plastic, dust protection.

Code L Indicationsmm

Dust protection for dark light fittingsdirect/indirect light versions.Transparent plastic, dust protection.

Code

Joint.Angular joint.

Code

Joint.Circular angular joint.

Page 15: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

“9000”

96

A9653GR

A9653 BI•GR 3x36

BI

GR

90

484

484

pag. 341CL I IP20 FSD

2G11

Code LampsWatt matt low luminance louvre

Three lamps light fitting direct light forPhilips compact fluorescent lamps,matt low luninance louvre.

Louvre low luminance matt paraboliclouver in aluminium 99,9% anodizedwith transverse parabolic blades comple-tely closed in the upper part. Very highperformance, antiridescent, luminance < 200 cd/m2 for angles > 65° transver-sal and longitudinal (EN 12464-1).

Wiring on request

A ____ /E one lamp emergency continuous light with magnetic ballast

EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous

light with electronic ballastED______ 220-240V 50-60Hz electronic

dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous

light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)

Colours

Page 16: “9000” - Laser Lightinglaserlighting.com.au/Web/indoor/Novalux/Profile/9000.pdf · 2020. 4. 22. · pag. 339-340 CL I IP20 FD G13 Code Lamps L high gloss low Watt mm luminance

97

“9000”

For the side shown installation use jointA9005.. 90° angle.

For the side shown installation find thejoints inside the fixture.