ATEX Certified Pt100 sensors

LEX15A Explosion Proof ResistanceThermometer EEx e for zone 1 and 2

II 2 G EEx e II T6 certified.According EN50014 and EN50019Designed to measure temperatures inexplosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Thermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head DAN-AKwith swing cover.Stainless steel connection headoptional.Cable entry M20x1.5mm.Replaceable 6mm springloadedinsert.Sensor Pt100 2, 3 or 4 wire system.Accuracy to IEC 751 class A, B orbetter.Single or duplex.Can be delivered with head mountedtransmitter.Insertion length as required.

Ordering code

Type LEX15A

LEX15B Explosion Proof ResistanceThermometer Eex e for zone 1 and 2

II 2 G EEx e II T6 certified.According EN50014 and EN50019Designed to measure temperatures inexplosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Thermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head model CEwith threaded cover.Stainless steel connection headoptional.Cable entry M20x1.5mm.Replaceable 6mm springloadedinsert.Sensor Pt100 2, 3 or 4 wire system.Accuracy to IEC 751 class A, B orbetter.Single or duplex.Can be delivered with head mountedtransmitter.Insertion length as required

Ordering code

Type LEX15B

LEX15C Explosion Proof ResistanceThermometer EEx e for zone 1 and 2

II 2 G EEx e II T6 certifiedAccording EN50014 and EN50019Designed to measure temperatures inindustrial explosive environments withgaseous or liquid.Temperature sensor range: -200°C to550°C.Sensor Pt100 2, 3 or 4 wire system.Single or duplex.Accuracy to IEC 751 class A, B orbetter.Direct connected PVC, PE or PTFEcable with screen and drainwire.Optional: armoured cable.Epoxy filled pot seal IP65 rated.Sensor diameter to be specified.Length as required.Process connection by an optionalcompression gland or feedthrough

Ordering code

Type LEX15C

LEX15 Pt100 Thermometer EEx e with Integrated 2-Wire Transmitter

II 2 G EEx e II T6 for zone 1 & 2.According EN50014 and EN50019Transmitter integrated, model andrange to be specified.Designed to measure temperatures inexplosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Replaceable springloaded 6mminsert.Accuracy to IEC 751 class BThermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head DAN-AKwith swing cover.Stainless steel connection headoptional. Cable entry M20x1.5mm.Insertion length as required.

Ordering code

Type LEX15

Weteringweg 102641 KM PijnackerThe Netherlands

Phone +31 (0)15 - 3621200Fax +31 (0)15 - 3694082

Email sales@thermo.nlInternet http://www.thermo-electra.com

ATEX Certified Pt100 sensors

LEX25A Explosion Proof ResistanceThermometer EExi for zone 0,1 and 2

II 1 G EEx ia IIC T4..T6 certified.According EN50014, EN50020 andEN50284Designed to measure temperatures inexplosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Thermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head DAN-AKwith swing cover. Stainless steelconnection head optional.Cable entry M20x1.5mm.Replaceable springloaded 6mmmeasuring insert.Sensor Pt100 2, 3 or 4 wire system.Accuracy to IEC 751 class A, B orbetter. Single or duplex.Can be delivered with head mountedintrinsically safe transmitter.Insertion length as required.

Ordering code

Type LEX25A

LEX25B Explosion Proof ResistanceThermometer Eexi for zone 0,1 and 2

II 1 G EEx ia IIC T4..T6 certified.According EN50014, EN50020 andEN50284Designed to measure temperatures inindustrial explosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Thermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head model CEwith threaded cover. Stainless steelconnection head optional.Cable entry M20x1.5mm.Replaceable springloaded 6mmmeasuring insert.Sensor Pt100 2, 3 or 4 wire system.Accuracy to IEC 751 class A, B orbetter. Single or duplex.Can be delivered with head mountedintrinsically safe transmitter.Insertion length as required

Ordering code

Type LEX25B

LEX25C Explosion Proof ResistanceThermometer EExi for zone 0,1 and 2

II 1 G EEx ia IIC T4..T6 certified.According EN50014, EN50020 andEN50284Designed to measure temperatures inindustrial explosive environments withgaseous or liquid.Temperature sensor range: -200°C to550°C. Sensor Pt100 2, 3 or 4 wiresystem. Single or duplex.Accuracy to IEC 751 class A, B orbetter.Insertion length and diameter asrequired.Process connection by an optionalcompression gland or feedthroughDirect connected PVC, PE or PTFEcable with screen and drainwire.Optional: armoured cable.Epoxy filled pot seal IP65 rated.

Ordering code

Type LEX25C

LEX25 Pt100 Thermometer EEx i with Integrated Transmitter

According EN50014, EN50020 andEN50284 for area 0,1 & 2.Intrisically safe transmitter integrated,model and range to be specified.Designed to measure temperatures inexplosive gaseous or liquidenvironments. Sensor Pt100 2, 3 or 4wire system. Single or duplex. Accuracy to IEC 751 class A, B orbetter.Temperature range: -200°C to 550°C.Thermowell connection by a 1/2"NPTnipple union nipple.Aluminium connection head DAN-AKwith swing cover.Stainless steel connection headoptional.Cable entry M20x1.5mm.Insertion length as required.

Ordering code

Type LEX25

Weteringweg 102641 KM PijnackerThe Netherlands

Phone +31 (0)15 - 3621200Fax +31 (0)15 - 3694082

Email sales@thermo.nlInternet http://www.thermo-electra.com

ATEX Certified Pt100 sensors

LEX30 Explosion Proof ResistanceThermometer EEx d for zone 1 and 2

II 2 G EEx d IIC T6 certified.According EN50014 and EN50018Designed to measure temperatures inindustrial explosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C. Sensor Pt100 2, 3 or 4 wiresystem.Accuracy to IEC 751 class A, B orbetter. Single or duplex.Thermowell connection by a 1/2"NPTFire Lock nipple union nipple.Aluminium connection head modelXD-AD or Stainless Steel EExdconnection head with threaded cover.Cable entry M20x1.5mm or 1/2"NPT.Replaceable springloaded 6mmmeasuring insert.Can be delivered with integral headmounted transmitter.Insertion length as required.

Ordering code

Type LEX30

LEX30 Pt100 Thermometer EEx dwith Integrated 2-Wire Transmitter

II 2 G EEx d IIC T6 certified.According EN50014 and EN50018Transmitter integrated, model andrange to be specified.Designed to measure temperatures inindustrial explosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C. Sensor Pt100 2, 3 or 4 wiresystem.Accuracy to IEC 751 class A, B orbetter. Single or duplex.Thermowell connection by a 1/2"NPTFire Lock nipple union nipple.Aluminium connection head modelXD-AD or Stainless Steel EExdconnection head with threaded cover.Cable entry M20x1.5mm or 1/2"NPT.Replaceable 6mm insert with 10mmspring action.Insertion length as required.

Ordering code

Type LEX30

LEX35A Explosion Proof ResistanceThermometer EEx d for zone 1 and 2

II 2 G EEx d IIC T6 certified.According EN50014 and EN50018Designed to measure temperatures inindustrial explosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Sensor Pt100 2, 3 or 4 wire system.Single or duplex. Accuracy to IEC 751class A, B or better.Insertion length as required.Process connection by an optionalcompression gland or feedthroughDirect connected PVC/PE cable withscreen and drainwire.Sensor diameter to be specified.Direct connected PVC/PE cable withscreen and drainwire.Screen electrical isolated from themetal sensor sheath.

Ordering code

Type LEX35A

LEX35B Explosion Proof ResistanceThermometer EEx d for zone 1 and 2

II 2 G EEx d IIC T6 certified.According EN50014 and EN50018Designed to measure temperatures inindustrial explosive gaseous or liquidenvironments.Temperature sensor range: -200°C to550°C.Sensor Pt100 2, 3 or 4 wire system.Single or duplex. Accuracy to IEC 751class A, B or better.Insertion length as required.Process connection by an optionalcompression gland or feedthroughDirect connected PVC/PE cable withscreen and drainwire.Sensor diameter to be specified.Direct connected PVC/PE cable withscreen and drainwire.Screen electrical connected to themetal sensor sheath

Ordering code

Type LEX35B