tcdi operation until ls2 liu-sps-to-lhc transfer line protection devices (tcdi) review 1 oliver...
Post on 03-Jan-2016
215 Views
Preview:
TRANSCRIPT
O. Aberle (EN-STI-TCD) 1
TCDI operation until LS2
LIU-SPS-to-LHC Transfer Line Protection Devices (TCDI) Review
Oliver Aberle26/03/2014
2
Outline
• Actual Design
• Flexibility / Sacrificial?
• From a single unit towards couples?
• Modifications / Options
• ConclusionO. Aberle (EN-STI-TCD)
3
Actual Design
O. Aberle (EN-STI-TCD)
• Flange to flange length 1.34 m• Graphite blocks R4550, 1.2 m long, 37 mm thick,
clamped• 2 independent motors per jaw• Flatness over 1.2 m: 0.1 mm
Parallelism over 1.2 m: 0.1 mm• Alignement by survey: 0.1 mm
4
Actual Design
O. Aberle (EN-STI-TCD)
• Phase one table• Flange DN 60!• No RF fingers/ferrites• No water cooling• No quick connection (electrical or for
vacuum) • No plug-in for positioning
5
Flexibility / Sacrificial?
O. Aberle (EN-STI-TCD)
• Keep design featureso from TCDI/ring collimators (e.g. quick plugin, integrated BPM) and profit fromo collimator development (e.g. new materials, manufacturing technologies)
• Stay within the actual length for a mono-block jawo Two TCDIs with the existing design (1.2 m), maybe different jaw
material?o Jaw clamping system allows assembly of different materials on the same beamo Overall positioning precision TCDIs ~250 µm.o Relative positioning between the two neighboring TCDIs ~50 µm.o Would have 4 motors per TCDI “jaw”o Very important: Best knowledge of beam position
• With bellows etc.: 3.5 m for full flexibilityo Flexibility = exchange only first one in case of beam impact
O. Aberle (EN-STI-TCD) 6
7
From single unit towards couples?
• LIU TCDIs = long TCDIs• 1.9 m long TCDIs (for densities of graphite, BN)• Longer/low density – preferable for thermo-mechanics
(adding a second TCDI -> 2.4 m length)• Higher density for better efficiency
(start with Graphite, go to higher density downstream)
• 2 main options:o Stand alone unitso coupled units
O. Aberle (EN-STI-TCD)
8
From single unit towards
couples?
• 2 main options:o Stand alone unitso coupled units
• Pumping module allows for fast separation, remote handling and to use spare surface
O. Aberle (EN-STI-TCD)
3200 mm
9O. Aberle (EN-STI-TCD)
MKT vacuum connection
Modifications / Options
10
Modifications / Options
O. Aberle (EN-STI-TCD)
• Integrated BPMo Significant higher complexity of design
• Water cooling / RF issues
• Remote handling to be studiedo Several features available o Reduced tunnel space and different slope!
• Normal operation – low dose• Accident case – high dose, but fast cool down
(see Helmut’s talk)
11
Conclusion
• Stay close to dimensions of proven designo TCDI design for simpler, cheaper manufacturing, more material flexibilityo TCTP design has more optionso Pick form both options – other input (e.g. TDI?)
• Two units can do the job
• More studies needed (see previous talks)
• Feasibility to have new system ready for LS2
• Rough number for the budget: 500 kCHF / unito Options have a cost (cable length!, remote handling)