surface water about us elemental analysis material
Post on 15-Jan-2022
0 Views
Preview:
TRANSCRIPT
UNIVERSITI PUTRA
MALAYSIA (UPM)
ABOUT US
Experienced, trained and very competent analyst.
MATERIAL CHARACTERIZATION
LABORATORY
Support all research activities for undergraduate and post graduate studies.
Accredited with MS ISO/IEC 17025:2015 (SAMM No. 711) for two analytical services under the cluster of chemical and physical.
We offer facilities for chemical and physical c h a r a c t e r i z a t i o n testing and services including imaging, s p e c t r o s c o p y , c h r o m a t o g r a p h y , thermal and laser analysis.
SURFACE WATER ELEMENTAL
ANALYSIS
Accepted Sample Criteria:
Treated Clear Surface
Water Sample
Minimum volume 20mL
Standard is provided
Testing are based on
APHA 3111B
Accepted Sample
Criteria:
Amorphous region:
from 30 to 300°C
Sample weight:
5 to 20mg
Example of sample:
polymeric material and mixture plastic, fibers
and adhesive
Testing are based on
ASTM E 1356-98 &
ASTM E 967-03
We offer to you the Glass Transition (Tg)
determination testing for amorphous materials, partially crystalline materials using Differential Scanning Calorimetry (DSC)
Type Of Surface Water :
Reservoir
Wetland
River
Lake
The determination of elemental concentration by using Flame Atomic Absorption Spectrometry (AAS) at parts per million (ppm) level.
PRICE:
RM230/SAMPLE
FOR MORE INFORMATION, PLEASE CONTACT :
MATERIAL CHARACTERIZATION LABORATORY DEPARTMENT OF CHEMICAL AND ENVIRONMENTAL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITI PUTRA MALAYSIA, 43400 UPM SERDANG, SELANGOR, MALAYSIA.
TEL : +603-89471595
FAX: +603-86567120
EMAIL: kkamcl1595@gmail.com
MATERIAL
CHARACTERIZATION
LABORATORY
(MCL)
PRICE:
RM80/ELEMENT/
SAMPLE
GLASS TRANSITION (Tg) DETERMINATION
ANALYSIS
Elements Concentration range (ppm)
Nickel (Ni) 0.09 to 0.30
Zinc (Zn) 0.10 to 1.00
Copper (Cu) 0.10 to 1.00
SPECTROSCOPY ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Elemental analysis especially in surface water sample
Atomic Absorption
Spectrophotometer (AAS)
80/element/sample
An analytical technique (Detection of trace metals in environmental samples)
Inductively Coupled Plasma
(ICP-OES)
190 (fixed cost) and 7/
element/sample
Functional group determination
ATR technique
Fourier Transform Infra-red
Spectroscopy (FTIR )
130/sample
Analysis of compound
In a range of observed light & UV light
UV-Visible Spectrophotometer
(UV-Vis) 50/hour
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Glass transition (Tg)
Melting point
Crystallinity
Specific heat
Differential Scanning
Calorimetry (DSC) 230/sample
Compositional Analysis
Thermal Gravimetric
Analysis (TGA) 230/sample
Elemental analysis C, H, N, S
Liquid or solid sample
CHNS Analyzer
CHN: 260/sample
S: 250/sample
Mechanical and strength testing
Room temperature
to 600°C only
Dynamic
Mechanical
Analyzer (DMA)
170/sample
CHROMATOGRAPHY ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Compound separation in gas or liquid form.
Gas Chromatography (GC)- FID/ECD
130 (1st injection) and 30/injection for subsequent
injection
Gas Chromatography
(GC)- TCD
80 (1st injection) and 40/injection for subsequent
injection
Gas Chromatography
Mass Spectrometry
(GC-MS)
380/sample
High Performance Liquid
Chromatography (HPLC) UV
105 (fixed cost) & 45 for subsequent
Injection Separate and Identify liquid compound
High resolution chromatography technique
High Performance Liquid
Chromatography (HPLC) RI/ELSD
Detector
100 (fixed cost) & 35 for subsequent
Injection
ANALYSIS PRICE (RM)
Biological Oxygen Demand (BOD) 50/sample
Chemical Oxygen Demand (COD) 100/sample
Total Organic Content (TOC) 10/sample
Turbidity 30/sample
pH 5/ sample
Total Dissolved Solid (TDS) 10/sample
Total Suspended Solid (TSS) 30/sample
Bomb Calorimeter 30/sample
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
A Microscope uses electron to form an image
Scanning Electron
Microscope (SEM) 240/sample
Elemental analysis or chemical characterization of a sample
Scanning Electron
Microscope With Energy-dispersive X
-ray spectroscopy (SEM-EDX)
385/sample
WATER ANALYSIS
MICROSCOPY ANALYSIS
THERMAL ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Surface area and porosity characterization
Brunauer- Emmett-Teller (BET)
Analyzer 425/sample
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Measure the size of sample distribution using laser diffraction
Micrometer range (0.1-1000)
Particle Size Analyzer (Malvern)
55/sample
LASER ANALYSIS
PHYSICAL ANALYSIS
top related