DESIGN FEATURES
STM pumps are peripheral turbine pumps designed for
low flow high head applications and directly replace
Caster MTA pumps..
Turbine Pumps
1
3
2
ANSI 300 RF connections.
Internal re-circulation to rear pump housing.
SiC shaft with SiC bearing as standard to give
improved chemical and mechanical resistance.
4
6
5
STM RangeMagnetically Driven Pumps
Peripheral turbine require a low NPSH and can
pump liquids with 20% entrained gases.
7
Powerful Samarium Colbalt magnets that allow
STM pumps to cope with high SGs and liquid otemperatures up to 315 C.
Optional long coupled.
Slot for PT 100 temperature probe on ATEX
versions.
The STM pumps are supplemented by the SVM rotary
vane pumps to API 676..
52
3
1 64 7 8
8
Hastelloy or single piece titanium rear housing.
SPECIFICATIONS
Maximum Temp 315 oC
Minimum Temp -150 oC
Max Flow 9 m3/hr
Max Head 95 m
Max Pressures 250 bar total system
ATEX Yes
DESIGN SUMMARY
Standards API 685 (deviations) - ISO 15783
Configuration Horizontal long or close coupled
Motors IEC, NEMA
Seal Type Magnetic Drive
MATERIALS
Standard Options
Rear Casing HC276 Ti Gr.5
Front Casing CF8M SS HC276, Ti Gr.5
Impeller CF8M SS HC276, Ti Gr.5
Shaft SiC 316 Hard,
Shaft Bearings SiC PTFE, Carbon
Thrust Bearings Carbon PTFE
O Ring: Viton EPDM, FEP
Magnets Samarium Colbalt
Optional carbon steel motor bracket to give
secondary containment..
9
9
-
STM - Performance Curves
2950 rpm
He
ad
me
tre
sTurbine Pumps
3m /hour
0
20
30
40
80
1.0 2.0 2.5 3.0 4.0 5.0 7.00
10
50
60
70
90
8.0 10.0
100
6.0
2x71.5x6
2.5x8 2.5x8.5
2.5x9
120
140
160
12.0
3x14
Page 1Page 2