POLYESTER ENCLOSURES
Presentation 3/2
Selection guide 3/4
SYSTEM 27 Insulating modular boxes 3/14
POLYMEL PLM Monobloc polyester enclosures 3/38
PLAPolyester enclosures 3/68
PLDPolyester enclosures and plinths 3/118
03_000_001_EN.ndd 303_000_001_EN.ndd 3 2/4/08 12:38:532/4/08 12:38:53
3/2
Fibreglass-reinforced polyester enclosures
PLM enclosure installed inside or outside in harsh environments: petrochemical, cement plants, paper plants, iron and steel producers, etc.
PLA enclosures resistant to corrosive chemical and atmospheric agents.
PLD enclosure with incorporated ZD plinth, electrical distribution application.
Inst
alla
tio
n s
yste
ms
Enc
losu
re
feat
ures
WALL MOUNTING
POLYMELSystem 27
Page 3/14 3/38
Degree of protection IP65/IK09 IP66/IK10
No. of sizes/models 14/35 8/26
Dimensions (mm) from 180 270 180 310 215 160
up to 540 720 230 1056 852 350
Mounting plates
Metal
Insulating
Universal
Distribution Chassis
18 mm modules up to 48 up to 240
Internal doors
Canopies
Plinths Acc
es-
sorie
s
03_002_013_EN.indd 203_002_013_EN.indd 2 2/4/08 12:40:282/4/08 12:40:28
3/3
c Insulating modular boxes system 27: composed of the base, with high and low cover variations, transparent and opaque, made of polycarbonate or polyester.
c POLYMEL polyester enclosures:monobloc construction, one single piece highly resistant body, with possible enclosure coupling.
c PLA polyester enclosures and plinths:4 construction systems: – fully closed enclosures, – enclosures with self-ventilated top with canopy and closed bottom, – enclosures with closed top and open plinth-type bottom, – enclosures with self-ventilated top with canopy and open plinth-type bottom.Enclosures with front door, and enclosures with front door and back door. 3 versions of doors: plain, transparent or ribbed.
c PLD-ZD polyester enclosures and plinths:prepared to directly incorporate the fuse holder plinths for electrical distribution.
FLOOR STANDING
3/68 3/118
PLA PLD-ZD
IP65/54/IK10 IP43/54/IK10
40/960 5/5
500 500 320 850 465 320
1500 1250 420 850 1115 320
up to 364
03_002_013_EN.indd 303_002_013_EN.indd 3 2/4/08 12:40:322/4/08 12:40:32
3/4
Hot-press moulded polyester enclosures Selection guide
180 270 180 PLS 1827 - PLSO 1827 - PLSP 1827 FPLS 1827 N TPLS 1827 -
270 270 180 PLS 2727 - PLSO 2727 - PLSP 2727 FPLS 2727 N TPLS 2727 -
270 270 230 - PLS 2727 A - PLSO 2727A - FPLS 2727 N - TPLS 2727 A
270 360 180 PLS 2736 - PLSO 2736 - PLSP 2736 FPLS 2736 N TPLS 2736 -
270 360 230 - PLS 2736 A - PLSO 2736 A - FPLS 2736 N - TPLS 2736 A 270 540 180 PLS 2754 - PLSO 2754 - PLSP 2754 FPLS 2754 N TPLS 2754 -
270 540 230 - PLS 2754 A - PLSO 2754 A - FPLS 2754 N - TPLS 2754 A
360 360 180 PLS 3636 - PLSO 3636 - PLSP 3636 FPLS 3636 N TPLS 3636 -
360 540 180 PLS 3654 - PLSO 3654 - PLSP 3654 FPLS 3654 N TPLS 3654 -
360 540 230 - PLS 3654 A - PLSO 3654 A - FPLS 3654 N - TPLS 3654 A
540 540 180 PLS 5454 - PLSO 5454 - PLSP 5454 FPLS 5454 N TPLS 5454 -
540 540 230 - PLS 5454 A - PLSO 5454 A - FPLS 5454 N - TPLS 5454 A
360 720 230 - PLS 3672 A - PLSO 3672 A - FPLS 3672 N - TPLS 3672 A
540 720 230 - PLS 5472 A - PLSO 5472 A - FPLS 5472 N - TPLS 5472 A
Low cover ref.Height Width Depth
Page 3/17 3/17 3/17 3/17 3/17 3/17 3/17 3/17
High cover ref. Low cover ref.High cover ref. Low cover ref.High cover ref.
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Transparent cover boxes Opaque cover boxes Polyester box cover Bases Transparent covers
System 27
Box dimensions (mm)
310 215 160 PLM-32 - PLM-32/KT - MB-32 MP-32 MM-32 MF-32 MR-32 -
308 255 160 PLM-3025 - PLM-3025/KT - MB-3025 MP-3025 MM-3025 MF-3025 MR-3025 -
430 330 200 PLM-43 PLM-43/CME PLM-43/KT PLM-43 KT/CME MB-43 MP-43 MM-43 MF-43 MR-43 DPLM-200
530 430 200 PLM-54 PLM-54/CME PLM-54/KT PLM-54 KT/CME MB-54 MP-54 MM-54 MF-54 MR-54 DPLM-200
647 436 250 PLM-64 PLM-64/CME PLM-64/KT PLM-64 KT/CME MB-64 MP-64 MM-64 MF-64 MR-64 DPLM-250
747 536 300 PLM-75 PLM-75/CME PLM-75/KT PLM-75 KT/CME MB-75 MP-75 MM-75 MF-75 MR-75 DPLM-300N
847 636 300 PLM-86 PLM-86/CME PLM-86/KT PLM-86 KT/CME MB-86 MP-86 MM-86 MF-86 MR-86 DPLM-300N
1000 800 350 PLM-108 - PLM-108/KT - MB-108 MP-108 MM-108 MF-108 MR-108 DPLM-350
Enclosure dimensions (mm)
Height Width Depth
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Plain Three-point Plain Three-point MetalMicroper-
foratedUniversalperforated
Enclosures with plain doors
Enclosures with transparent doors
Mounting platesAdjustable
plate support
Page 3/41 3/41 3/41 3/41 3/48 3/48 3/48 3/48 3/48 3/49
Lock Lock
Bakelite
Polymel
Polyester
Insulating
03_002_013_EN.indd 403_002_013_EN.indd 4 2/4/08 12:40:332/4/08 12:40:33
3/5
TPLSO 1827 - TPLSP 1827 PMM 1827 PMA 1827 PMA/B 1827 12 1 S27 DL/12 DL 27/12
TPLSO 2727 - TPLSP 2727 PMM 2727 PMA 2727 PMA/B 2727 24 2 S27 DL24 DL 27/24
- TPLSO 2727 A - PMM 2727 PMA 2727 PMA/B 2727 - - - DL 27/24
TPLSO 2736 - TPLSP 2736 PMM 2736 PMA 2736 PMA/B 2736 24 2 S27 DL/24-2 DL 27/24-2
S27 DL/36 DL 27/36
- TPLSO 2736 A - PMM 2736 PMA 2736 PMA/B 2736 - - - DL 27/24-2
DL 27/36
TPLSO 2754 - TPLSP 2754 PMM 2754 PMA 2754 PMA/B 2754 48 4 S27 DL748 DL 27/48
- TPLSO 2754 A - PMM 2754 PMA 2754 PMA/B 2754 - - - DL 27/48
TPLSO 3636 - TPLSP 3636 PMM 3636 PMA 3636 PMA/B 3636 - - - -
TPLSO 3654 - TPLSP 3654 PMM 3654 PMA 3654 PMA/B 3654 - - - -
- TPLSO 3654 A - PMM 3654 PMA 3654 PMA/B 3654 - - - -
TPLSO 5454 - TPLSP 5454 PMM 5454 PMA 5454 PMA/B 5454 - - - -
- TPLSO 5454 A - PMM 5454 PMA 5454 PMA/B 5454 - - - -
- TPLSO 3672 A - PMM 3672 PMA 3672 PMA/B 3672 - - - -
- TPLSO 5472 A - PMM 5472 PMA 5472 PMA/B 5472 - - - -
3/17 3/17 3/17 3/17 3/17 3/17 3/35 3/17
Steel Polyester Bakelite No. of rows ReferenceLow cover ref. High cover ref.No. of modules
18 mm
Opaque covers Polyester covers Boxes with DINMEL modular chassis DINMEL chassis Mounting plates
- - - - - - - -
DL/PLM18 2 2 18 - PI-3025/PLM - -
DLA-24 2 2 24 - PIP-43 SFP-300 -
DLA-48 3 3 48 - PIP-54 SFP-400 SFS/PLM
DLA-48P 3 3 48 - PIP-64 SFP-400 SFS/PLM
DLA-66 4 3 66 1
PIP-75 SFP-500 - 4 4 88 -
DLA-84 4 3 84 1 PIP-86 SFP-600 -
DLA112 4 4 112 -
DLA-240 6 6 234 - PIP-108 - -
Reference No. of rows Quantity
Automatic rail
No. of modules 18 mm
No. of plates
DINIMEL chassis Internal door set Post fixing set Floor-mounting pillar
3/63 3/45 3/45 3/43
03_002_013_EN.indd 503_002_013_EN.indd 5 2/4/08 12:40:412/4/08 12:40:41
3/6
Hot-press moulded polyester enclosures Selection guide
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Height Width DepthNo. of doors
Nominal dimensions (mm)
IP65
120°
Flat
PlainDoor
Lock
Door opening
Degree of protection
Ribbed Transparent
Completely closedPLA enclosures with rear panel
500 500 320 1 PLA 553 PLA 553 R PLA 553 KT PLA 553 T PLA 553 TR PLA 553 TKT
420 1 PLA 554 PLA 554 R PLA 554 KT PLA 554 T PLA 554 TR PLA 554 TKT
750 320 1 PLA 573 PLA 573 R PLA 573 KT PLA 573 T PLA 573 TR PLA 573 TKT
420 1 PLA 574 PLA 574 R PLA 574 KT PLA 574 T PLA 574 TR PLA 574 TKT
1000 320 2 PLA 5103 PLA 5103 R PLA 5103 KT PLA 5103 T PLA 5103 TR PLA 5103 TKT
420 2 PLA 5104 PLA 5104 R PLA 5104 KT PLA 5104 T PLA 5104 TR PLA 5104 TKT
1250 320 2 PLA 5123 PLA 5123 R PLA 5123 KT PLA 5123 T PLA 5123 TR PLA 5123 TKT
420 2 PLA 5124 PLA 5124 R PLA 5124 KT PLA 5124 T PLA 5124 TR PLA 5124 TKT
750 500 320 1 PLA 753 PLA 753 R PLA 753 KT PLA 753 T PLA 753 TR PLA 753 TKT
420 1 PLA 754 PLA 754 R PLA 754 KT PLA 754 T PLA 754 TR PLA 754 TKT
750 320 1 PLA 773 PLA 773 R PLA 773 KT PLA 773 T PLA 773 TR PLA 773 TKT
420 1 PLA 774 PLA 774 R PLA 774 KT PLA 774 T PLA 774 TR PLA 774 TKT
1000 320 2 PLA 7103 PLA 7103 R PLA 7103 KT PLA 7103 T PLA 7103 TR PLA 7103 TKT
420 2 PLA 7104 PLA 7104 R PLA 7104 KT PLA 7104 T PLA 7104 TR PLA 7104 TKT
1250 320 2 PLA 7123 PLA 7123 R PLA 7123 KT PLA 7123 T PLA 7123 TR PLA 7123 TKT
420 2 PLA 7124 PLA 7124 R PLA 7124 KT PLA 7124 T PLA 7124 TR PLA 7124 TKT
1000 500 320 1 PLA 1053 PLA 1053 R PLA 1053 KT PLA 1053 T PLA 1053 TR PLA 1053 TKT
420 1 PLA 1054 PLA 1054 R PLA 1054 KT PLA 1054 T PLA 1054 TR PLA 1054 TKT
750 320 1 PLA 1073 PLA 1073 R PLA 1073 KT PLA 1073 T PLA 1073 TR PLA 1073 TKT
420 1 PLA 1074 PLA 1074 R PLA 1074 KT PLA 1074 T PLA 1074 TR PLA 1074 TKT
1000 320 2 PLA 10103 PLA 10103 R PLA 10103 KT PLA 10103 T PLA 10103 TR PLA 10103 TKT
420 2 PLA 10104 PLA 10104 R PLA 10104 KT PLA 10104 T PLA 10104 TR PLA 10104 TKT
1250 320 2 PLA 10123 PLA 10123 R PLA 10123 KT PLA 10123 T PLA 10123 TR PLA 10123 TKT
420 2 PLA 10124 PLA 10124 R PLA 10124 KT PLA 10124 T PLA 10124 TR PLA 10124 TKT
1250 500 320 1 PLA 1253 PLA 1253 R PLA 1253 KT PLA 1253 T PLA 1253 TR PLA 1253 TKT
420 1 PLA 1254 PLA 1254 R PLA 1254 KT PLA 1254 T PLA 1254 TR PLA 1254 TKT
750 320 1 PLA 1273 PLA 1273 R PLA 1273 KT PLA 1273 T PLA 1273 TR PLA 1273 TKT
420 1 PLA 1274 PLA 1274 R PLA 1274 KT PLA 1274 T PLA 1274 TR PLA 1274 TKT
1000 320 2 PLA 12103 PLA 12103 R PLA 12103 KT PLA 12103 T PLA 12103 TR PLA 12103 TKT
420 2 PLA 12104 PLA 12104 R PLA 12104 KT PLA 12104 T PLA 12104 TR PLA 12104 TKT
1250 320 2 PLA 12123 PLA 12123 R PLA 12123 KT PLA 12123 T PLA 12123 TR PLA 12123 TKT
420 2 PLA 12124 PLA 12124 R PLA 12124 KT PLA 12124 T PLA 12124 TR PLA 12124 TKT
1500 500 320 1 PLA 1553 PLA 1553 R PLA 1553 KT PLA 1553 T PLA 1553 TR PLA 1553 TKT
420 1 PLA 1554 PLA 1554 R PLA 1554 KT PLA 1554 T PLA 1554 TR PLA 1554 TKT
750 320 1 PLA 1573 PLA 1573 R PLA 1573 KT PLA 1573 T PLA 1573 TR PLA 1573 TKT
420 1 PLA 1574 PLA 1574 R PLA 1574 KT PLA 1574 T PLA 1574 TR PLA 1574 TKT
1000 320 2 PLA 15103 PLA 15103 R PLA 15103 KT PLA 15103 T PLA 15103 TR PLA 15103 TKT
420 2 PLA 15104 PLA 15104 R PLA 15104 KT PLA 15104 T PLA 15104 TR PLA 15104 TKT
1250 320 2 PLA 15123 PLA 15123 R PLA 15123 KT PLA 15123 T PLA 15123 TR PLA 15123 TKT
420 2 PLA 15124 PLA 15124 R PLA 15124 KT PLA 15124 T PLA 15124 TR PLA 15124 TKT
IP54
120°
Handle
Plain Ribbed Transparent
Self-ventilated top with canopy
Page 3/73 3/73 3/73 3/75 3/75 3/75
PLA
03_002_013_EN.indd 603_002_013_EN.indd 6 2/4/08 12:40:432/4/08 12:40:43
3/7
PLAZ 553 PLAZ 553 R PLAZ 553 KT PLAZ 553 T PLAZ 553 TR PLAZ 553 TKT
PLAZ 554 PLAZ 554 R PLAZ 554 KT PLAZ 554 T PLAZ 554 TR PLAZ 554 TKT
PLAZ 573 PLAZ 573 R PLAZ 573 KT PLAZ 573 T PLAZ 573 TR PLAZ 573 TKT
PLAZ 574 PLAZ 574 R PLAZ 574 KT PLAZ 574 T PLAZ 574 TR PLAZ 574 TKT
PLAZ 5103 PLAZ 5103 R PLAZ 5103 KT PLAZ 5103 T PLAZ 5103 TR PLAZ 5103 TKT
PLAZ 5104 PLAZ 5104 R PLAZ 5104 KT PLAZ 5104 T PLAZ 5104 TR PLAZ 5104 TKT
PLAZ 5123 PLAZ 5123 R PLAZ 5123 KT PLAZ 5123 T PLAZ 5123 TR PLAZ 5123 TKT
PLAZ 5124 PLAZ 5124 R PLAZ 5124 KT PLAZ 5124 T PLAZ 5124 TR PLAZ 5124 TKT
PLAZ 753 PLAZ 753 R PLAZ 753 KT PLAZ 753 T PLAZ 753 TR PLAZ 753 TKT
PLAZ 754 PLAZ 754 R PLAZ 754 KT PLAZ 754 T PLAZ 754 TR PLAZ 754 TKT
PLAZ 773 PLAZ 773 R PLAZ 773 KT PLAZ 773 T PLAZ 773 TR PLAZ 773 TKT
PLAZ 774 PLAZ 774 R PLAZ 774 KT PLAZ 774 T PLAZ 774 TR PLAZ 774 TKT
PLAZ 7103 PLAZ 7103 R PLAZ 7103 KT PLAZ 7103 T PLAZ 7103 TR PLAZ 7103 TKT
PLAZ 7104 PLAZ 7104 R PLAZ 7104 KT PLAZ 7104 T PLAZ 7104 TR PLAZ 7104 TKT
PLAZ 7123 PLAZ 7123 R PLAZ 7123 KT PLAZ 7123 T PLAZ 7123 TR PLAZ 7123 TKT
PLAZ 7124 PLAZ 7124 R PLAZ 7124 KT PLAZ 7124 T PLAZ 7124 TR PLAZ 7124 TKT
PLAZ 1053 PLAZ 1053 R PLAZ 1053 KT PLAZ 1053 T PLAZ 1053 TR PLAZ 1053 TKT
PLAZ 1054 PLAZ 1054 R PLAZ 1054 KT PLAZ 1054 T PLAZ 1054 TR PLAZ 1054 TKT
PLAZ 1073 PLAZ 1073 R PLAZ 1073 KT PLAZ 1073 T PLAZ 1073 TR PLAZ 1073 TKT
PLAZ 1074 PLAZ 1074 R PLAZ 1074 KT PLAZ 1074 T PLAZ 1074 TR PLAZ 1074 TKT
PLAZ 10103 PLAZ 10103 R PLAZ 10103 KT PLAZ 10103 T PLAZ 10103 TR PLAZ 10103 TKT
PLAZ 10104 PLAZ 10104 R PLAZ 10104 KT PLAZ 10104 T PLAZ 10104 TR PLAZ 10104 TKT
PLAZ 10123 PLAZ 10123 R PLAZ 10123 KT PLAZ 10123 T PLAZ 10123 TR PLAZ 10123 TKT
PLAZ 10124 PLAZ 10124 R PLAZ 10124 KT PLAZ 10124 T PLAZ 10124 TR PLAZ 10124 TKT
PLAZ 1253 PLAZ 1253 R PLAZ 1253 KT PLAZ 1253 T PLAZ 1253 TR PLAZ 1253 TKT
PLAZ 1254 PLAZ 1254 R PLAZ 1254 KT PLAZ 1254 T PLAZ 1254 TR PLAZ 1254 TKT
PLAZ 1273 PLAZ 1273 R PLAZ 1273 KT PLAZ 1273 T PLAZ 1273 TR PLAZ 1273 TKT
PLAZ 1274 PLAZ 1274 R PLAZ 1274 KT PLAZ 1274 T PLAZ 1274 TR PLAZ 1274 TKT
PLAZ 12103 PLAZ 12103 R PLAZ 12103 KT PLAZ 12103 T PLAZ 12103 TR PLAZ 12103 TKT
PLAZ 12104 PLAZ 12104 R PLAZ 12104 KT PLAZ 12104 T PLAZ 12104 TR PLAZ 12104 TKT
PLAZ 12123 PLAZ 12123 R PLAZ 12123 KT PLAZ 12123 T PLAZ 12123 TR PLAZ 12123 TKT
PLAZ 12124 PLAZ 12124 R PLAZ 12124 KT PLAZ 12124 T PLAZ 12124 TR PLAZ 12124 TKT
PLAZ 1553 PLAZ 1553 R PLAZ 1553 KT PLAZ 1553 T PLAZ 1553 TR PLAZ 1553 TKT
PLAZ 1554 PLAZ 1554 R PLAZ 1554 KT PLAZ 1554 T PLAZ 1554 TR PLAZ 1554 TKT
PLAZ 1573 PLAZ 1573 R PLAZ 1573 KT PLAZ 1573 T PLAZ 1573 TR PLAZ 1573 TKT
PLAZ 1574 PLAZ 1574 R PLAZ 1574 KT PLAZ 1574 T PLAZ 1574 TR PLAZ 1574 TKT
PLAZ 15103 PLAZ 15103 R PLAZ 15103 KT PLAZ 15103 T PLAZ 15103 TR PLAZ 15103 TKT
PLAZ 15104 PLAZ 15104 R PLAZ 15104 KT PLAZ 15104 T PLAZ 15104 TR PLAZ 15104 TKT
PLAZ 15123 PLAZ 15123 R PLAZ 15123 KT PLAZ 15123 T PLAZ 15123 TR PLAZ 15123 TKT
PLAZ 15124 PLAZ 15124 R PLAZ 15124 KT PLAZ 15124 T PLAZ 15124 TR PLAZ 15124 TKT
IP54
120°
Handle
Plain Ribbed Transparent
Open plinth-type base
IP54
180°
Handle
Plain Ribbed Transparent
Self-ventilating top with canopy and open plinth-type base
3/77 3/77 3/77 3/79 3/79 3/79
03_002_013_EN.indd 703_002_013_EN.indd 7 2/4/08 12:40:442/4/08 12:40:44
3/8
Page 3/73 3/73 3/73 3/75 3/75 3/75
Hot-press moulded polyester enclosures Selection guide
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Height Width DepthNo. of doors
Nominal dimensions (mm)
IP65
120°
Flat
PlainDoor
Lock
Door opening
Degree of protection
Ribbed Transparent
Completely closedPLA enclosures with rear door
500 500 320 1 PLA 553 P PLA 553 PR PLA 553 PKT PLA 553 TP PLA 553 TPR PLA 553 TPKT
420 1 PLA 554 P PLA 554 PR PLA 554 PKT PLA 554 TP PLA 554 TPR PLA 554 TPKT
750 320 1 PLA 573 P PLA 573 PR PLA 573 PKT PLA 573 TP PLA 573 TPR PLA 573 TPKT
420 1 PLA 574 P PLA 574 PR PLA 574 PKT PLA 574 TP PLA 574 TPR PLA 574 TPKT
1000 320 2 PLA 5103 P PLA 5103 PR PLA 5103 PKT PLA 5103 TP PLA 5103 TPR PLA 5103 TPKT
420 2 PLA 5104 P PLA 5104 PR PLA 5104 PKT PLA 5104 TP PLA 5104 TPR PLA 5104 TPKT
1250 320 2 PLA 5123 P PLA 5123 PR PLA 5123 PKT PLA 5123 TP PLA 5123 TPR PLA 5123 TPKT
420 2 PLA 5124 P PLA 5124 PR PLA 5124 PKT PLA 5124 TP PLA 5124 TPR PLA 5124 TPKT
750 500 320 1 PLA 753 P PLA 753 PR PLA 753 PKT PLA 753 TP PLA 753 TPR PLA 753 TPKT
420 1 PLA 754 P PLA 754 PR PLA 754 PKT PLA 754 TP PLA 754 TPR PLA 754 TPKT
750 320 1 PLA 773 P PLA 773 PR PLA 773 PKT PLA 773 TP PLA 773 TPR PLA 773 TPKT
420 1 PLA 774 P PLA 774 PR PLA 774 PKT PLA 774 TP PLA 774 TPR PLA 774 TPKT
1000 320 2 PLA 7103 P PLA 7103 PR PLA 7103 PKT PLA 7103 TP PLA 7103 TPR PLA 7103 TPKT
420 2 PLA 7104 P PLA 7104 PR PLA 7104 PKT PLA 7104 TP PLA 7104 TPR PLA 7104 TPKT
1250 320 2 PLA 7123 P PLA 7123 PR PLA 7123 PKT PLA 7123 TP PLA 7123 TPR PLA 7123 TPKT
420 2 PLA 7124 P PLA 7124 PR PLA 7124 PKT PLA 7124 TP PLA 7124 TPR PLA 7124 TPKT
1000 500 320 1 PLA 1053 P PLA 1053 PR PLA 1053 PKT PLA 1053 TP PLA 1053 TPR PLA 1053 TPKT
420 1 PLA 1054 P PLA 1054 PR PLA 1054 PKT PLA 1054 TP PLA 1054 TPR PLA 1054 TPKT
750 320 1 PLA 1073 P PLA 1073 PR PLA 1073 PKT PLA 1073 TP PLA 1073 TPR PLA 1073 TPKT
420 1 PLA 1074 P PLA 1074 PR PLA 1074 PKT PLA 1074 TP PLA 1074 TPR PLA 1074 TPKT
1000 320 2 PLA 10103 P PLA 10103 PR PLA 10103 PKT PLA 10103 TP PLA 10103 TPR PLA 10103 TPKT
420 2 PLA 10104 P PLA 10104 PR PLA 10104 PKT PLA 10104 TP PLA 10104 TPR PLA 10104 TPKT
1250 320 2 PLA 10123 P PLA 10123 PR PLA 10123 PKT PLA 10123 TP PLA 10123 TPR PLA 10123 TPKT
420 2 PLA 10124 P PLA 10124 PR PLA 10124 PKT PLA 10124 TP PLA 10124 TPR PLA 10124 TPKT
1250 500 320 1 PLA 1253 P PLA 1253 PR PLA 1253 PKT PLA 1253 TP PLA 1253 TPR PLA 1253 TPKT
420 1 PLA 1254 P PLA 1254 PR PLA 1254 PKT PLA 1254 TP PLA 1254 TPR PLA 1254 TPKT
750 320 1 PLA 1273 P PLA 1273 PR PLA 1273 PKT PLA 1273 TP PLA 1273 TPR PLA 1273 TPKT
420 1 PLA 1274 P PLA 1274 PR PLA 1274 PKT PLA 1274 TP PLA 1274 TPR PLA 1274 TPKT
1000 320 2 PLA 12103 P PLA 12103 PR PLA 12103 PKT PLA 12103 TP PLA 12103 TPR PLA 12103 TPKT
420 2 PLA 12104 P PLA 12104 PR PLA 12104 PKT PLA 12104 TP PLA 12104 TPR PLA 12104 TPKT
1250 320 2 PLA 12123 P PLA 12123 PR PLA 12123 PKT PLA 12123 TP PLA 12123 TPR PLA 12123 TPKT
420 2 PLA 12124 P PLA 12124 PR PLA 12124 PKT PLA 12124 TP PLA 12124 TPR PLA 12124 TPKT
1500 500 320 1 PLA 1553 P PLA 1553 PR PLA 1553 PKT PLA 1553 TP PLA 1553 TPR PLA 1553 TPKT
420 1 PLA 1554 P PLA 1554 PR PLA 1554 PKT PLA 1554 TP PLA 1554 TPR PLA 1554 TPKT
750 320 1 PLA 1573 P PLA 1573 PR PLA 1573 PKT PLA 1573 TP PLA 1573 TPR PLA 1573 TPKT
420 1 PLA 1574 P PLA 1574 PR PLA 1574 PKT PLA 1574 TP PLA 1574 TPR PLA 1574 TPKT
1000 320 2 PLA 15103 P PLA 15103 PR PLA 15103 PKT PLA 15103 TP PLA 15103 TPR PLA 15103 TPKT
420 2 PLA 15104 P PLA 15104 PR PLA 15104 PKT PLA 15104 TP PLA 15104 TPR PLA 15104 TPKT
1250 320 2 PLA 15123 P PLA 15123 PR PLA 15123 PKT PLA 15123 TP PLA 15123 TPR PLA 15123 TPKT
420 2 PLA 15124 P PLA 15124 PR PLA 15124 PKT PLA 15124 TP PLA 15124 TPR PLA 15124 TPKT
IP54
120°
Handle
Plain Ribbed Transparent
Self-ventilated top with canopy
PLA
03_002_013_EN.indd 803_002_013_EN.indd 8 2/4/08 12:40:452/4/08 12:40:45
3/9
3/77 3/77 3/77 3/79 3/79 3/79
PLAZ 553 P PLAZ 553 PR PLAZ 553 PKT PLAZ 553 TP PLAZ 553 TPR PLAZ 553 TPKT
PLAZ 554 P PLAZ 554 PR PLAZ 554 PKT PLAZ 554 TP PLAZ 554 TPR PLAZ 554 TPKT
PLAZ 573 P PLAZ 573 PR PLAZ 573 PKT PLAZ 573 TP PLAZ 573 TPR PLAZ 573 TPKT
PLAZ 574 P PLAZ 574 PR PLAZ 574 PKT PLAZ 574 TP PLAZ 574 TPR PLAZ 574 TPKT
PLAZ 5103 P PLAZ 5103 PR PLAZ 5103 PKT PLAZ 5103 TP PLAZ 5103 TPR PLAZ 5103 TPKT
PLAZ 5104 P PLAZ 5104 PR PLAZ 5104 PKT PLAZ 5104 TP PLAZ 5104 TPR PLAZ 5104 TPKT
PLAZ 5123 P PLAZ 5123 PR PLAZ 5123 PKT PLAZ 5123 TP PLAZ 5123 TPR PLAZ 5123 TPKT
PLAZ 5124 P PLAZ 5124 PR PLAZ 5124 PKT PLAZ 5124 TP PLAZ 5124 TPR PLAZ 5124 TPKT
PLAZ 753 P PLAZ 753 PR PLAZ 753 PKT PLAZ 753 TP PLAZ 753 TPR PLAZ 753 TPKT
PLAZ 754 P PLAZ 754 PR PLAZ 754 PKT PLAZ 754 TP PLAZ 754 TPR PLAZ 754 TPKT
PLAZ 773 P PLAZ 773 PR PLAZ 773 PKT PLAZ 773 TP PLAZ 773 TPR PLAZ 773 TPKT
PLAZ 774 P PLAZ 774 PR PLAZ 774 PKT PLAZ 774 TP PLAZ 774 TPR PLAZ 774 TPKT
PLAZ 7103 P PLAZ 7103 PR PLAZ 7103 PKT PLAZ 7103 TP PLAZ 7103 TPR PLAZ 7103 TPKT
PLAZ 7104 P PLAZ 7104 PR PLAZ 7104 PKT PLAZ 7104 TP PLAZ 7104 TPR PLAZ 7104 TPKT
PLAZ 7123 P PLAZ 7123 PR PLAZ 7123 PKT PLAZ 7123 TP PLAZ 7123 TPR PLAZ 7123 TPKT
PLAZ 7124 P PLAZ 7124 PR PLAZ 7124 PKT PLAZ 7124 TP PLAZ 7124 TPR PLAZ 7124 TPKT
PLAZ 1053 P PLAZ 1053 PR PLAZ 1053 PKT PLAZ 1053 TP PLAZ 1053 TPR PLAZ 1053 TPKT
PLAZ 1054 P PLAZ 1054 PR PLAZ 1054 PKT PLAZ 1054 TP PLAZ 1054 TPR PLAZ 1054 TPKT
PLAZ 1073 P PLAZ 1073 PR PLAZ 1073 PKT PLAZ 1073 TP PLAZ 1073 TPR PLAZ 1073 TPKT
PLAZ 1074 P PLAZ 1074 PR PLAZ 1074 PKT PLAZ 1074 TP PLAZ 1074 TPR PLAZ 1074 TPKT
PLAZ 10103 P PLAZ 10103 PR PLAZ 10103 PKT PLAZ 10103 TP PLAZ 10103 TPR PLAZ 10103 TPKT
PLAZ 10104 P PLAZ 10104 PR PLAZ 10104 PKT PLAZ 10104 TP PLAZ 10104 TPR PLAZ 10104 TPKT
PLAZ 10123 P PLAZ 10123 PR PLAZ 10123 PKT PLAZ 10123 TP PLAZ 10123 TPR PLAZ 10123 TPKT
PLAZ 10124 P PLAZ 10124 PR PLAZ 10124 PKT PLAZ 10124 TP PLAZ 10124 TPR PLAZ 10124 TPKT
PLAZ 1253 P PLAZ 1253 PR PLAZ 1253 PKT PLAZ 1253 TP PLAZ 1253 TPR PLAZ 1253 TPKT
PLAZ 1254 P PLAZ 1254 PR PLAZ 1254 PKT PLAZ 1254 TP PLAZ 1254 TPR PLAZ 1254 TPKT
PLAZ 1273 P PLAZ 1273 PR PLAZ 1273 PKT PLAZ 1273 TP PLAZ 1273 TPR PLAZ 1273 TPKT
PLAZ 1274 P PLAZ 1274 PR PLAZ 1274 PKT PLAZ 1274 TP PLAZ 1274 TPR PLAZ 1274 TPKT
PLAZ 12103 P PLAZ 12103 PR PLAZ 12103 PKT PLAZ 12103 TP PLAZ 12103 TPR PLAZ 12103 TPKT
PLAZ 12104 P PLAZ 12104 PR PLAZ 12104 PKT PLAZ 12104 TP PLAZ 12104 TPR PLAZ 12104 TPKT
PLAZ 12123 P PLAZ 12123 PR PLAZ 12123 PKT PLAZ 12123 TP PLAZ 12123 TPR PLAZ 12123 TPKT
PLAZ 12124 P PLAZ 12124 PR PLAZ 12124 PKT PLAZ 12124 TP PLAZ 12124 TPR PLAZ 12124 TPKT
PLAZ 1553 P PLAZ 1553 PR PLAZ 1553 PKT PLAZ 1553 TP PLAZ 1553 TPR PLAZ 1553 TPKT
PLAZ 1554 P PLAZ 1554 PR PLAZ 1554 PKT PLAZ 1554 TP PLAZ 1554 TPR PLAZ 1554 TPKT
PLAZ 1573 P PLAZ 1573 PR PLAZ 1573 PKT PLAZ 1573 TP PLAZ 1573 TPR PLAZ 1573 TPKT
PLAZ 1574 P PLAZ 1574 PR PLAZ 1574 PKT PLAZ 1574 TP PLAZ 1574 TPR PLAZ 1574 TPKT
PLAZ 15103 P PLAZ 15103 PR PLAZ 15103 PKT PLAZ 15103 TP PLAZ 15103 TPR PLAZ 15103 TPKT
PLAZ 15104 P PLAZ 15104 PR PLAZ 15104 PKT PLAZ 15104 TP PLAZ 15104 TPR PLAZ 15104 TPKT
PLAZ 15123 P PLAZ 15123 PR PLAZ 15123 PKT PLAZ 15123 TP PLAZ 15123 TPR PLAZ 15123 TPKT
PLAZ 15124 P PLAZ 15124 PR PLAZ 15124 PKT PLAZ 15124 TP PLAZ 15124 TPR PLAZ 15124 TPKT
IP54
120°
Handle
Plain Ribbed Transparent
Open plinth-type base
IP54
180°
Handle
Plain Ribbed Transparent
Self-ventilating top with canopy and open plinth-type base
03_002_013_EN.indd 903_002_013_EN.indd 9 2/4/08 12:40:452/4/08 12:40:45
3/10
Nominal dimensions (mm)
Height Width DepthNo. of doors
TABLE OF MODELS, DIMENSIONS AND REFERENCES
500 500 320 1 PMM 55 PMB 55 PMA 55 PMR 55 - - -
420 1 PMM 55 PMB 55 PMA 55 PMR 55 - - -
750 320 1 PMM 75 PMB 75 PMA 75 PMR 57 - - -
420 1 PMM 75 PMB 75 PMA 75 PMR 57 - - -
1000 320 2 PMM 510 PMB 510 PMA 510 PMR 55 + PMR 55 - - -
420 2 PMM 510 PMB 510 PMA 510 PMR 55 + PMR 55 - - -
1250 320 2 PMM 55 + PMM 75 PMB 55 + PMB 75 PMA 55 + PMA 75 PMR 55 + PMR 57 - - -
420 2 PMM 55 + PMM 75 PMB 55 + PMB 75 PMA 55 + PMA 75 PMR 55 + PMR 57 - - -
750 500 320 1 PMM 75 PMB 75 PMA 75 PMR 75 MOL 75 DLP 57/76 57/76
420 1 PMM 75 PMB 75 PMA 75 PMR 75 MOL 75 DLP 57/76 57/76
750 320 1 PMM 77 PMB 77 PMA 77 PMR 77 MOL 75 DLP 99/132 99/132
420 1 PMM 77 PMB 77 PMA 77 PMR 77 MOL 75 DLP 99/132 99/132
1000 320 2 PMM 710 PMB 710 PMA 710 PMR 75 + PMR 75 MOL 75 DLP 57/76 + DLP 57/76 114/152
420 2 PMM 710 PMB 710 PMA 710 PMR 75 + PMR 75 MOL 75 DLP 57/76 + DLP 57/76 114/152
1250 320 2 PMM 712 PMB 712 PMA 712 PMR 75 + PMR 77 MOL 75 DLP 57/76 + DLP 99/132 156/208
420 2 PMM 712 PMB 712 PMA 712 PMR 75 + PMR 77 MOL 75 DLP 57/76 + DLP 99/132 156/208
1000 500 320 1 PMM 105 PMB 105 PMA 105 PMR 105 MOL 100 DLP 95/114 95/114
420 1 PMM 105 PMB 105 PMA 105 PMR 105 MOL 100 DLP 95/114 95/114
750 320 1 PMM 107 PMB 107 PMA 107 PMR 107 MOL 100 DLP 165/198 165/198
420 1 PMM 107 PMB 107 PMA 107 PMR 107 MOL 100 DLP 165/198 165/198
1000 320 2 PMM 1010 PMB 1010 PMA 1010 PMR 105 + PMR 105 MOL 100 DLP 95/114 + DLP 95/114 190/228
420 2 PMM 1010 PMB 1010 PMA 1010 PMR 105 + PMR 105 MOL 100 DLP 95/114 + DLP 95/114 190/228
1250 320 2 PMM 1012 PMB 1012 PMA 1012 PMR 105 + PMR 107 MOL 100 DLP 95/114 + DLP 165/198 260/312
420 2 PMM 1012 PMB 1012 PMA 1012 PMR 105 + PMR 107 MOL 100 DLP 95/114 + DLP 165/198 260/312
1250 500 320 1 PMM 125 PMB 125 PMA 125 PMR 125 MOL 125 DLP 114 P/133 114/133
420 1 PMM 125 PMB 125 PMA 125 PMR 125 MOL 125 DLP 114 P/133 114/133
750 320 1 PMM 127 PMB 127 PMA 127 PMR 127 MOL 125 DLP 198 P/231 198/231
420 1 PMM 127 PMB 127 PMA 127 PMR 127 MOL 125 DLP 198P/231 198/231
1000 320 2 PMM 1210 PMB 1210 PMA 1210 PMR 125 + PMR 125 MOL 125 DLP 114P/133 + DLP 114P/133 228/266
420 2 PMM 1210 PMB 1210 PMA 1210 PMR 125 + PMR 125 MOL 125 DLP 114P/133 + DLP 114P/133 228/266
1250 320 2 PMM 1212 PMB 1212 PMA 1212 PMR 125 + PMR 127 MOL 125 DLP 114P/133 + DLP 198P/231 312/364
420 2 PMM 1212 PMB 1212 PMA 1212 PMR 125 + PMR 127 MOL 125 DLP 114P/133 + DLP 198P/231 312/364
1500 500 320 1 PMM 155 PMB 155 - PMR 155 MOL 150 - -
420 1 PMM 155 PMB 155 - PMR 155 MOL 150 - -
750 320 1 PMM 157 PMB 157 - PMR 157 MOL 150 - -
420 1 PMM 157 PMB 157 - PMR 157 MOL 150 - -
1000 320 2 PMM 1510 PMB 1510 - PMR 155 + PMR 155 MOL 150 - -
420 2 PMM 1510 PMB 1510 - PMR 155 + PMR 155 MOL 150 - -
1250 320 2 PMM 1512 PMB 1512 - PMR 155 + PMR 157 MOL 150 - -
420 2 PMM 1512 PMB 1512 - PMR 155 + PMR 157 MOL 150 - -
Metal mounting plate
Insulating mounting plate Universal perforated mounting plate
Set of 2 profiles for universal chassis
Modular distribution chassis
Hot-press moulded polyester enclosures Selection guide
No. of modules 18 mm
Reference
Page 3/93 3/94 3/94 3/95 3/97 3/112
(1) Only for enclosures with closed base reference PLA…(2) Only for enclosures with open plinth-type base reference PLAZ…
PLA
Bakelite Polyester
03_002_013_EN.indd 1003_002_013_EN.indd 10 2/4/08 12:40:462/4/08 12:40:46
3/11
PIPLA 55 ZNPLA 53 ZHPLA 53 TJPLA 53
PIPLA 55 ZNPLA 54 ZHPLA 54 TJPLA 54
BRF 8 PLA 8 - - PIPLA 57 ZNPLA 73 ZHPLA 73 TJPLA 73
BRF 8 PLA 8 BRP 7 PLA 7 PIPLA 57 ZNPLA 74 ZHPLA 74 TJPLA 74
PIPLA 55 + PIPLA 55 ZNPLA 103 ZHPLA 103 TJPLA 103
PIPLA 55 + PIPLA 55 ZNPLA 104 ZHPLA 104 TJPLA 104
PIPLA 55 + PIPLA 57 ZNPLA 123 ZHPLA 123 TJPLA 123
PIPLA 55 + PIPLA 57 ZNPLA 124 ZHPLA 124 TJPLA 124
PIPLA 75 ZNPLA 53 ZHPLA 53 TJPLA 53
PIPLA 75 ZNPLA 54 ZHPLA 54 TJPLA 54
BRF 12 PLA 12 - - PIPLA 77 ZNPLA 73 ZHPLA 73 TJPLA 73
BRF 12 PLA 12 BRP 11 PLA 11 PIPLA 77 ZNPLA 74 ZHPLA 74 TJPLA 74
PIPLA 75 + PIPLA 75 ZNPLA 103 ZHPLA 103 TJPLA 103
PIPLA 75 + PIPLA 75 ZNPLA 104 ZHPLA 104 TJPLA 104
PIPLA 75 + PIPLA 77 ZNPLA 123 ZHPLA 123 TJPLA 123
PIPLA 75 + PIPLA 77 ZNPLA 124 ZHPLA 124 TJPLA 124
PIPLA 105 ZNPLA 53 ZHPLA 53 TJPLA 53
PIPLA 105 ZNPLA 54 ZHPLA 54 TJPLA 54
BRF 17 PLA 17 - - PIPLA 107 ZNPLA 73 ZHPLA 73 TJPLA 73
BRF 17 PLA 17 BRP 16 PLA 16 PIPLA 107 ZNPLA 74 ZHPLA 74 TJPLA 74
PIPLA 105 + PIPLA 105 ZNPLA 103 ZHPLA 103 TJPLA 103
PIPLA 105 + PIPLA 105 ZNPLA 104 ZHPLA 104 TJPLA 104
PIPLA 105 + PIPLA 107 ZNPLA 123 ZHPLA 123 TJPLA 123
PIPLA 105 + PIPLA 107 ZNPLA 124 ZHPLA 124 TJPLA 124
PIPLA 125 ZNPLA 53 ZHPLA 53 TJPLA 53
PIPLA 125 ZNPLA 54 ZHPLA 54 TJPLA 54
BRF 21 PLA 21 - - PIPLA 127 ZNPLA 73 ZHPLA 73 TJPLA 73
BRF 21 PLA 21 BRP 20 PLA 20 PIPLA 127 ZNPLA 74 ZHPLA 74 TJPLA 74
PIPLA 125 + PIPLA 125 ZNPLA 103 ZHPLA 103 TJPLA 103
PIPLA 125 + PIPLA 125 ZNPLA 104 ZHPLA 104 TJPLA 104
PIPLA 125 + PIPLA 127 ZNPLA 123 ZHPLA 123 TJPLA 123
PIPLA 125 + PIPLA 127 ZNPLA 124 ZHPLA 124 TJPLA 124
PIPLA 155 ZNPLA 53 ZHPLA 53 TJPLA 53
PIPLA 155 ZNPLA 54 ZHPLA 54 TJPLA 54
BRF 26 PLA 26 - - PIPLA 157 ZNPLA 73 ZHPLA 73 TJPLA 73
BRF 26 PLA 26 BRP 25 PLA 25 PIPLA 157 ZNPLA 74 ZHPLA 74 TJPLA 74
PIPLA 155 + PIPLA 155 ZNPLA 103 ZHPLA 103 TJPLA 103
PIPLA 155 + PIPLA 155 ZNPLA 104 ZHPLA 104 TJPLA 104
PIPLA 155 + PIPLA 157 ZNPLA 123 ZHPLA 123 TJPLA 123
PIPLA 155 + PIPLA 157 ZNPLA 124 ZHPLA 124 TJPLA 124
19” fixed rack
19” pivoting rack
Internal doors Bases (1) Plinths (2) Canopies
No. of units1 = 44.45 mm
3/118 3/118 3/89 3/85 3/86 3/86
No. of units1 = 44.45 mm
03_002_013_EN.indd 1103_002_013_EN.indd 11 2/4/08 12:40:542/4/08 12:40:54
3/12
Hot-press moulded polyester enclosures Selection guide
Height Width Depth Reference Reference Reference ReferenceNo. of doors
No. of locks
No. of plates per enclosure
850 465 320 PLD-85/00 1 1 APLD-85 1 ZD-53/00 BPLD
850 590 320 PLD-86/0 1 1 APLD-86 1 ZD-63/0 BPLD
850 785 320 PLD-88/1 1 1 APLD-88 1 ZD-83/1 BPLD
850 1115 320 PLD-812/2 2 1 APLD-812 2 ZD-123/2 BPLD
850 1115 320 PLD-812/2C 2 2 APLD-812 2 ZD-123/2 BPLD
TABLE OF MODELS, DIMENSIONS AND REFERENCES
PLD-ZD
Page 3/121 3/121 3/123 3/125
Enclosure dimensions (mm)
Enclosures Mounting plates Plinth Rack
03_002_013_EN.indd 1203_002_013_EN.indd 12 2/4/08 12:40:562/4/08 12:40:56
3/13
03_002_013_EN.indd 1303_002_013_EN.indd 13 2/4/08 12:41:002/4/08 12:41:00
6 5
321
8 7
4
3/14
Insulating modular boxes resistant against outdoor conditions System 27
03_014_015_EN.indd 1403_014_015_EN.indd 14 2/4/08 12:42:162/4/08 12:42:16
3/15
5 Internal view without protective panel with detail of the neutral-earth terminal block of the modular chassis.
1 Possibility of using the interior part of the TPLSP cover (in PLSP polyester boxes) to fix the plates using an M5 insert.
2 Side lock (optional), may be available with key lock.
4 Rear view of box with PF-27 wall-fixing piece in place.
8 M6 inserts for fixing the mounting plate or various equipment.
7 Sealable cover-base lock, screwdriver operated (standard supply).
6 Box completely mounted with detail of hinge, protective panel and removable blanking plate fixing.
3 Insulating polyester mounting plate fixed to the back. Option of metallic or bakelite plate.
03_014_015_EN.indd 1503_014_015_EN.indd 15 2/4/08 12:42:172/4/08 12:42:17
3/16
SYSTEM 27 Insulating modular boxesIP55 (EN 60529)
PLS 3654
Insulating modular boxes comprised of BASES made of fibreglass-reinforced polyester and COVERS made of polycarbonate or fibreglass-reinforced polyester, depending on the model.PLS and PLSO boxes with polycarbonate covers on the transparent and opaque versions.PLSP boxes with fibreglass-reinforced polyester covers.Opaque bases and covers in greyRAL-7032.
c Modular dimensions that, in addition to its individual use, permit coupling
of boxes.
c Self-extinguishing, double insulation.
c Sealing gasket between base and cover.
c Dielectric rigidity > 5 kV, insulation resistance > Ω.
c Operating temperature from –30 °C to 120 °C for PLS and PLSO models
and 150 °C for PLSP models.
c Easily machined with conventional tools.
c Locking screw, screwdriver operated (standard supply).
c IK09.
03_016_024_EN.indd 1603_016_024_EN.indd 16 2/4/08 12:46:032/4/08 12:46:03
3/17
Insulating modular boxesIP55 (EN 60529)SYSTEM 27
180 270 180 PLS 1827 PLSO 1827 PLSP 1827 - -
270 270 180 PLS 2727 PLSO 2727 PLSP 2727 - -
270 270 230 - - - PLS 2727 A PLSO 2727 A
270 360 180 PLS 2736 PLSO 2736 PLSP 2736 - -
270 360 230 - - - PLS 2736 A PLSO 2736 A
270 540 180 PLS 2754 PLSO 2754 PLSP 2754 - -
270 540 230 - - - PLS 2754 A PLSO 2754 A
360 360 180 PLS 3636 PLSO 3636 PLSP 3636 - -
360 540 180 PLS 3654 PLSO 3654 PLSP 3654 - -
360 540 230 - - - PLS 3654 A PLSO 3654 A
360 720 230 - - - PLS 3672 A PLSO 3672 A
540 540 180 PLS 5454 PLSO 5454 PLSP 5454 - -
540 540 230 - - - PLS 5454 A PLSO 5454 A
540 720 230 - - - PLS 5472 A PLSO 5472 A
Height(mm)
Width(mm)
Depth(mm)
Transparent Opaque Polyester Transparent
High cover boxes
Opaque
Low cover boxes
TABLE OF MODELS, DIMENSIONS AND REFERENCES, MODULAR BOXES
Height(mm)
Width(mm)
Depth(mm)
180 270 180 FPLS 1827 N TPLS 1827 TPLSO 1827 TPLSP 1827 - -
270 270 180 FPLS 2727 N TPLS 2727 TPLSO 2727 TPLSP 2727 - -
270 270 230 FPLS 2727 N - - - TPLS 2727 A TPLSO 2727 A
270 360 180 FPLS 2736 N TPLS 2736 TPLSO 2736 TPLSP 2736 - -
270 360 230 FPLS 2736 N - - - TPLS 2736 A TPLSO 2736 A
270 540 180 FPLS 2754 N TPLS 2754 TPLSO 2754 TPLSP 2754 - -
270 540 230 FPLS 2754 N - - - TPLS 2754 A TPLSO 2754 A
360 360 180 FPLS 3636 N TPLS 3636 TPLSO 3636 TPLSP 3636 - -
360 540 180 FPLS 3654 N TPLS 3654 TPLSO 3654 TPLSP 3654 - -
360 540 230 FPLS 3654 N - - - TPLS 3654 A TPLSO 3654 A
360 720 230 FPLS 3672 N - - - TPLS 3672 A TPLSO 3672 A
540 540 180 FPLS 5454 N TPLS 5454 TPLSO 5454 TPLSP 5454 - -
540 540 230 FPLS 5454 N - - - TPLS 5454 A TPLSO 5454 A
540 720 230 FPLS 5472 N - - - TPLS 5472 A TPLSO 5472 A
Base 135 mm
Opaque 45 mm Polyester 45 mm Transparent 95 mm
High cover
Opaque 95 mm
Low cover
TABLE OF MODELS, DIMENSIONS AND REFERENCES, BASES AND COVERS
Transparent45 mm
Mounting plates Modular chassis
To be coupled to boxes(dimensions)
Metal Polyester Bakelite
To be coupled to boxes(dimensions)
Height (mm) Width (mm) Height (mm) Width (mm) Reference No. of modules
180 270 PMM 1827 PMA 1827 PMA/B 1827 180 270 DL 27/12 12
270 270 PMM 2727 PMA 2727 PMA/B 2727 270 270 DL 27/24 24
270 360 PMM 2736 PMA 2736 PMA/B 2736 360 270DL 27/24-2DL 27/36
2436
270 540 PMM 2754 PMA 2754 PMA/B 2754 540 270 DL 27/48 48
360 540 PMM 3636 PMA 3636 PMA/B 3636
360 540 PMM 3654 PMA 3654 PMA/B 3654
360 720 PMM 3672 PMA 3672 PMA/B 3672
540 540 PMM 5454 PMA 5454 PMA/B 5454
540 720 PMM 5472 PMA 5472 PMA/B 5472
TABLE OF MODELS, DIMENSIONS AND REFERENCES, PLATES AND CHASSIS
03_016_024_EN.indd 1703_016_024_EN.indd 17 2/4/08 12:46:052/4/08 12:46:05
3/18
SYSTEM 27 Insulating modular boxesIP55 (EN 60529)
45
2
270200
2494 2
1
3
249
24924
9
270
200
122.2122.3
138 95
23*
45
2
180110
1591 3
2
4
159
24924
9
270
200
122.2122.3
138
45
2
360290
3394 2
1
3
339
24924
9
270
200
122.2122.3
138 95
23*
45
3
360290
339
4 2
1
3
339
339
339
360
290
122.212
2.7
138
54070200 200
5196 3
1 2
5 4
260 260
249
249
270
200
45
2.5122.2122.7
138 95
2.53*
72070290 290
6997 4
8 3
1 2
6 5
350 350
260
260
519
540
7020
020
0
122.212
2.7
138 95
4
72070290 290
699
6 3
1 2
5 4
350 350
339
339
360
290
122.212
2.7
138 95
3.5
54070200 200
5197 4
8 3
1 2
6 5
260 26026
026
0
519
540
7020
020
0
122.212
2.7
138 45 95
3 3
54070200 200
519
6 3
1 2
5 4
260 260
339
339
360
290
122.212
2.7
138 45 95
3 3
1827…
2727…
2736…
3636…
2754…
* The thickness of 3 mm corresponds to the polyester cover.
5472…
3672…
5454…
3654…
Dimensions (mm)
A Coupling to the back with low cover.B Coupling to the back with high cover..C D Interior view of back corner, detail of the bosses with M6 inserts.E F Interior view of the corner of the polyester cover with housing for the expandable nut.Ref.: TE-25 for M5 screws.
A C E
B D F
03_016_024_EN.indd 1803_016_024_EN.indd 18 2/4/08 12:46:062/4/08 12:46:06
3/19
Example of couplingSuite of general, busbar, meter and distribution boxes.
All boxes may be coupled on any of their sides. The coupling may be done using UM modular joints and PS fastening pieces.
Insulating modular boxesIP65 (EN 60529)SYSTEM 27
PS 2C-27 UM-27/270
S27-DL/48
Cover TL-27/270 with cable glands
TL-27/270UM-27/270EGB-27TL-27/270
03_016_024_EN.indd 1903_016_024_EN.indd 19 2/4/08 12:46:082/4/08 12:46:08
3/20
SYSTEM 27 Composition accessories
Manufactured with fibreglass-reinforced polycarbonate. Pieces prepared for coupling the boxes on any of their lateral sides.
c Sealing gasket on both sides.
c Supplied with all the hardware necessary for fixing and the openings template.
Modular couplings
ReferenceTo couple to openings (mm)
110 (nominal 180) UM 27/180
200 (nominal 270) UM 27/270
290 (nominal 360) UM 27/360
Side cut-out press, Ref.: PUC-27.
To order boxes with lateral openings, you must add the numbers of the sides that you wish to have cut to the reference of the basic box.These numbers are indicated on the dimensions panel as well as raised on the bases themselves. Example: a 270 × 540 mm box with low transparent cover and openings on sides 1, 3 and 5 would be: PLS-2754/1-3-5.
Openings
03_016_024_EN.indd 2003_016_024_EN.indd 20 2/4/08 12:46:102/4/08 12:46:10
3/21
Composition accessoriesSYSTEM 27
For coupling 2, 3, or 4 boxes with the possibility of wall fixing.
Box coupling pieces
ReferenceTo couple
2 boxes PS2C-27
3 or 4 boxes PS4C-27
M6×18 cylinder head screws.
Manufactured with fibreglass-reinforced polyester. Easily machined with conventional tools for cable entry.
c With a sealing gasket.
c Supplied with all the hardware necessary for fixing and the openings template.
Side covers
ReferenceTo couple to openings (mm) )
200 (nominal 270) TL 27/270
290 (nominal 360) TL 27/360
Wall-fixing parts
ReferenceMaterial
Passivated zinc-coated steel PF-27
Stainless steel PF-27/ I
03_016_024_EN.indd 2103_016_024_EN.indd 21 2/4/08 12:46:112/4/08 12:46:11
3/22
Transport handle
ReferenceMaterial
Polyamide ATM-27
Rail-fixing pieces
Stud∅ 8
Rail fixing Direct wall-fixing
RailCNT-20
M6×30cylinder head screw
50 mm long ribbedhead screw
NutBN-206
SYSTEM 27 Composition accessories
Has incorporated all the elements necessary for fixing and adjusting to a post.
Post fixing
ReferenceTo couple to module width (mm)
270 FSP-27/270
360 FSP-27/360
540 FSP-27/540
03_016_024_EN.indd 2203_016_024_EN.indd 22 2/4/08 12:46:132/4/08 12:46:13
Fig. 1
Fig. 2
Fig. 2Fig. 1
PPA-27
CL-27
CLL-27
TCD-27/4 N TCM-27/4 N
TCT-27/4 N
LT-27
3/23
Composition accessoriesSYSTEM 27
Locks for insulated modular boxes
Specifications ReferenceTypes of operation with
Set of 4 locks Screwdriver TCD-27/4 N
Set of 6 locks Standard supply in boxes (PLS) Screwdriver TCD-27/6 N
Set of 8 locks Screwdriver TCD-27/8 N
Set of 4 locks Manual TCM-27/4 N
Set of 6 locks Standard in boxes (S27DL) Manual TCM-27/6 N
Set of 8 locks Manual TCM-27/8 N
Set of 4 triangle locks LT-27 TCT-27/4 N
Set of 6 triangle locks LT-27 TCT-27/6 N
Set of 8 triangle locks LT-27 TCT-27/8 N
Double bar side lock, possibility DBP CL-27 of fixing the wing key to the lock
Side lock with key operation CLL-27
Metal sealing sheet PPA-27 (included in standard supply)
Insulated seal PPS-27
Triangle key LT-27
* In rows of 12 modules mounted vertically.** In rows of 17 modules mounted horizontally.
Allow access to the interior of the enclosure, maintaining the IP65 degree of protection.Made of transparent polycarbonate.
Windows for automatic switches
Fig. No.Low cover
Reference
High cover A B Low cover High coverNo. of
modules
C
VA 27/2M VA 27/2MA 2 1 78 60 15 25
VA 27/4M VA 27/4MA 4 1 78 95 15 25
VA 27/6M VA 27/6MA 6 1 78 130 15 25
VA 27/8M VA 27/8MA 8 1 78 165 15 25
VA 27/10M VA 27/10MA 10 1 78 200 15 25
VA 27/12M VA 27/12MA 12 1 78 235 15 25
VA 27/16M - 16 2 195 165 13 -
VA 27/24M - 24* 2 196 235 13 -
VA 27/36M - 36* 2 248 235 13 -
VA 27/51M - 51** 2 248 325 13 -
03_016_024_EN.indd 2303_016_024_EN.indd 23 2/4/08 12:46:142/4/08 12:46:14
3/24
SYSTEM 27 Mounting accessories
Mounting plates for fixing single-phase or three-phase meters made of polyester with fibre-glass, in RAL-7032.
Plates for meters
Single-phase Three-phaseTo couple to boxes
Height Width No. of meters Reference No. of meters Reference
270 270 1M P1M-27 - -
1M (displaced) P1M-P27 - -
270 360 1M P1M-2736 1T P1T-27
2M P2M-27 - -
270 540 2M P2M-27E 1T P1T-27E(1)
2M (vertical) P2M-27V - -
3M P3M-27 - -
360 540 4M P4M-27V 2T P2T-27
- - 3T P3T-27
540 540 6M P6M-27V 2T P2T-27E
- - 3T P3T-27E
360 720 5M P5M-27 3T P3T-27H
6M P6M-27V 4T P4T-27
540 720 8M P8M-27 3T P3T-27G
9M P9M-27 6T P6T-27
10M P10M-27 - -
(1) 1 vertical three-phase.
Metal insert nuts for fixing equipment on polyester and bakelite insulated mounting plates.
Fixing nuts
Thread MReference
TE-3 3
TE-4 4
TE-5 5
TE-6 6
TE-8 9
TE-10 10
TE-12 12
03_016_024_EN.indd 2403_016_024_EN.indd 24 2/4/08 12:46:172/4/08 12:46:17
3/25
Current distribution accessories
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Adjustable ties
White BlackL ∅
minimum∅
maximum
M
Reference Use
LZ25100 LN25100 100 2.5 1.6 22
LZ25200 LN25200 200 2.5 1.6 49
LZ35150 LN35150 150 3.5 1.6 35
LZ35200 LN35200 200 3.5 1.6 49
LZ35300 LN35300 300 3.5 1.6 75
LZ46150 LN46150 150 4.6 1.6 36
LZ46200 LN46200 200 4.6 1.6 49
LZ48270 LN48270 270 4.8 1.6 73
LZ46390 LN46390 390 4.6 1.6 109
LZ76390 LN76390 390 7.6 4.7 108
To tighten and cut the adjustable ties to size. They facilitate wiring and save time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the tool. Can be used on the following models of ties: LZ25100 up to LZ46390. Ref.: MARK20, 21.
Tightening tools
Reference
MARK3 2.5 ÷ 4.8
Admissible width ties
Reference
MARK20 2.5 ÷ 4.8
MARK21 4.6 ÷ 7.6
Admissible width ties
SYSTEM 27
03_025_037_EN.indd 2503_025_037_EN.indd 25 2/4/08 12:47:452/4/08 12:47:45
3/26
Current distribution accessories
To use with soft materials: 7 mm Ø hole, or hard materials: 8 mm Ø hole. Ties up to 9 mm in width can be coupled. Material: black 6.6 nylon.
Ref.: LOK01.
Stud
To attach one or two ties, mounted with a single screw. Material: 6.6 nylon. Allows for attaching ties from the entire range.
Tie fixing support
Reference A B Fixing screwAdmissible width
tiesC
KR6 12 18 9 M4 2.5 ÷ 4.8
KR8 14.5 25 12 M6 2.5 ÷ 7.6
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to 3.2 mm thick. Material: 6.6 nylon.
Locking clips
Reference
SFC1 6 3.2 1
SFC2 6 1 2
FigureMax. panel
thickness mm∅ perforation
mm
SFC2 SFC1
Fig. 1 Fig. 2
SYSTEM 27
03_025_037_EN.indd 2603_025_037_EN.indd 26 2/4/08 12:47:462/4/08 12:47:46
adhesive support
3/27
Current distribution accessories
Permits insertion of 1 tie from 4 points at a 90º angle. Attaches ties from the series LZ25100 up to LZ46390. Material: 6.6 nylon.
Self-adhesive support base
Reference A B C EAdmissible width
tiesD
MB3A 19.1 19.1 4.8 3.2 13.2 2.5 ÷ 3.5
MB4A 28.5 28.5 5.5 4 20.2 2.5 ÷ 4.8
To attach ties from any series. Material: 6.6 nylon.
Tie fixing support
Reference
LKC 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
To transform normal ties into ties with fixing heads, introduce a tie into this head before closing it on the cable bundle. Material: 6.6 nylon.
Support heads
Reference A B Fixing screwAdmissible width
tiesC
FH18 7.1 13.3 4 M4 2.5
FH30 9.5 17.9 4.7 M5 3.5
FH50 11.3 22.2 6.2 M6 4.7
SYSTEM 27
03_025_037_EN.indd 2703_025_037_EN.indd 27 2/4/08 12:47:482/4/08 12:47:48
3/28
Current distribution accessories
2 versions, fixed and adjustable, ∅ from 5 to 25.4 mm. Material: black 6.6 nylon.
Fixing loop for tubes, hoses, etc.
NX 1-3-5 NX 8-11-14
Reference∅ A
min. - max.B D EC
NX1 5 3.5 1 6.2 13.7
NX3 8 3.9 1 9.4 20.5
NX5 12 3.9 1 9.4 24
NX8* 14.3 ÷ 15.8 4 1.3 12.6 32
NX11 17.4 ÷ 20 4 1.3 12.6 37
NX14 22.2 ÷ 25.4 4.3 1.5 16 45
*The NX8 model only has 3 adjustment holes.
For tube or cable entry. Models EGB-27 made of neoprene.
Membrane gland
Covers the head of the tie in its end, thus obtaining neater cabling.
Material: 6.6 nylon.
Lateral tie fixing support
Reference
LKM/HE 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
SYSTEM 27
03_025_037_EN.indd 2803_025_037_EN.indd 28 2/4/08 12:47:492/4/08 12:47:49
Ø A
Ø B
3/29
Current distribution accessories
Insulating membrane glands made of PVC with entry that can be adjusted for cables or tubes (see page 3/30).
Adjustable membrane glands
Reference Fig. Ø A Ø B* Ø C Ø D E FØ cable Tube
Capacity
ECPC-3 1 25 21.5 18 5 3.2 13 5 to 18 Pg 9 to 11
ECPC-5 1 33 29.5 26 5 3.2 20 5 to 26 Pg 9 to 16
ECPC-6 1 43 38.5 36 5 3.2 22 5 to 36 Pg 9 to 21
ECPC-9 2 70 63 60 28 3 20 28 to 60 Pg 21 to 48
ECPC-15 2 98 90 87 28 3 23 28 to 87 Pg 21 to 48
* Mounting perforation.
SYSTEM 27
Fig. 1 Fig. 2
Small protective sleeves for cables coming out of tubes, as indicated in the instructions for MI BT 019. Made of flexible and durable PVC, in light grey colour.
Protective sleeves
Reference A Ø B Tube
PC-1 15.2 12.7 Pg 9
PC-2 18.6 16 Pg 11
PC-3 20.4 17.8 Pg 13.5
PC-4 22.5 19.8 Pg 16
PC-5 28.3 25.3 Pg 21
PC-6 37 33.6 Pg 29
PC-7 47 43 Pg 36
03_025_037_EN.indd 2903_025_037_EN.indd 29 2/4/08 12:47:502/4/08 12:47:50
3/30
Current distribution accessoriesSYSTEM 27
ASE 27/360
AE-25
AI-25
No. of platesTo couple to the side of
box (mm)ReferencePlate width (mm)
360 4 15/20 ASE 27/360
270 4 15/20 AE 25
- 1 15/20/30 AI 25
Insulators
To form busbars. Made of fibreglass-reinforced polycarbonate.
Useful information about Pg tubes and HIMEL accessories to be coupled
Desig-nation
Øexterior
SteelFlexible
steelPVC Insert Thread
Protective sleeves
Adjustable membrane
glandsPlain plugs
Adjustablemembrane glands
Flexible steel with
PVC
Cables inserted*Ø interior To the perforationsTo the tube
4 EC-1 to EC-7
Pg 9 15.2 12.7 12.4 12 11.1 6 2.5 - - 16 14 ECPC-3 to ECPC-6 PC-1 - -
ECN-5 to ECN-10
10 4 2.5 EC-2 to EC-7 EC-1
Pg 11 18.6 16 15.5 14.5 14.2 16 6 4 2.5 19 17.5 ECPC-5; ECPC-6 PC-2 EC-2 TC-1
25 ECN-5 to ECN-10 ECN-1
EC-3 to EC-7 EC-3
Pg 13.5 20.4 17.8 17.5 16.3 16 35 10 6 4 21 19.5 ECPC-5; ECPC-6 PC-3 ECPC-3 TC-2
ECN-5 to ECN-10
EC-4 to EC-7
Pg 16 22.5 19.8 18.7 18.5 17.6 50 16 10 6 23 21.5 ECPC-5; ECPC-6 PC-4 EC-4 TC-3
ECN-5 to ECN-10
EC-5 to EC-7 EC-5
Pg 21 28.3 25.3 24.7 23 23 70 25 16 10 29 27 ECPC-6 to ECPC-15 PC-5 ECPC-5 TC-4
ECN-6 to ECN-10 ECN-5
95 35 25 16 EC-6; EC-7 EC-6 TC-5
Pg 29 37 33.6 33.5 31 31 120 50 35 25 38 35.5 ECPC-9; ECPC-15 PC-6 ECPC-6 TCP-5
150 ECN-7; ECN-10 ECN-6
185 35 EC-7 EC-7
Pg 36 47 43 41.5 41 40.3 240 70 50 50 48 45.5 ECPC-9; ECPC-15 PC-7 ECN-7 TC-6
300 ECN-10
95 70 ECPC-9; ECPC-15
Pg 42 54 50 48 48 47 - 120 95 70 55 52.5 ECN-10 - - -
120 95 ECPC-9; ECPC-15
Pg 48 60 56 54.2 52.5 51.4 - 150 150 120 61 58 ECN-10 - - -
* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).
1 2 3 4
MODELS, DIMENSIONS AND REFERENCES
No. of conductors
Tubes HIMEL accessories to be coupled
Ø perforations to
03_025_037_EN.indd 3003_025_037_EN.indd 30 2/4/08 12:47:512/4/08 12:47:51
3/31
Current distribution accessoriesSYSTEM 27
Split bridges
ReferenceCable section mm2
95 TS-25/95
150 TS-25/150
240 TS-25/240
Base of safety terminals made of black matte self-extinguishing polyamide-6; terminal of brass MS-58
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that spreads the pressure out throughout the entire contact surface, avoiding the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the pressure exerted by the conductors cannot open the terminal and loosen the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap, avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of strips of any length. Service voltage: 500 V.
Sigma safety terminals
Reference
S.04 1 × 4 30 20 13 21 4
S.06 1 × 6 33 25 16 24 7
S.10 1 × 10 38 28 16 28 6
S.16 1 × 16 42 32 19 32 9
S.25/35 1 × 35 46 38 23 34 11
S.50 1 × 50 52 45 27 40 15
S.70 1 × 70 55 50 30 40 15
S.95/100 1 × 100 58 54 33 40 20
NOTE: each terminal accepts up to 2 conductors of the section indicated.
Section m/m2 A B C D E
03_025_037_EN.indd 3103_025_037_EN.indd 31 2/4/08 12:47:522/4/08 12:47:52
3/32
ReferenceCable bypass section (mm2)
Plate thickness (mm) Figure
Current distribution accessoriesSYSTEM 27
Terminals especially designed for branching cables on plates; their main application is busbar connection.
BBH terminals are made of a tinned, hot cast copper alloy and are suitable for connecting to a conductor of copper or aluminium indistinctly (bimetal).
Bimetal BBH terminals
Reference
BBH-29 6-50 -
BBH-29C* 6-50 -
BBH-30 10-95 -
BBH-31 16-150 -
BBH-32 50-240 -
BBH-29D 6-50 6-50
BBH-29DC* 6-50 6-50
BBH-30D 10-95 10-95
BBH-31D 25-150 16-150
BBH-32D 95-240 5-240
Main section(mm2)
Bypass section(mm2)
Reference
BBH-29P 6-50 -
BBH-29PC* 6-50 -
BBH-29DP 6-50 6-50
BBH-29DPC* 6-50 6-50
* Include terminal cover CBBH-29.
Main section (mm2)
Bypass section(mm2)
BBH-29 BBH-29D
BBH-29P BBH-29DP
Plate entry and bypass by cable.
Plate/cable terminals
1
* Included in standard supply.
Number of terminals × section in (mm2)
Earth and neutral bypass terminal blocks with insulated plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Bypass terminal blocks
RBLZ/21656* 2 × 16 mm2 + 5 × 6 mm2
RBLZ/21686 2 × 16 mm2 + 8 × 6 mm2
RBLZ/216146 2 × 16 mm2 + 14 × 6 mm2
RBLZ/216296 2 × 16 mm2 + 29 × 6 mm2
Reference
2
BPCH 516 1.5 to 16 5 2
BPCH 550 1.5 to 50 5 2
BPCH 5120 16 to 120 5 2
BPCH 1016 1.5 to 16 10 1
BPCH 1050 1.5 to 50 10 1
BPCH 10120 16 to 120 10 1
03_025_037_EN.indd 3203_025_037_EN.indd 32 2/4/08 12:47:532/4/08 12:47:53
3/33
Natural ventilation accessoriesComplementary accessories
Ventilation devices
To connect the inside of the enclosure with the exterior atmosphere and prevent condensation.
Specifications Reference
∅ 19 VM-25
∅ 29 VM-27
SYSTEM 27
VM-25 VM-27
03_025_037_EN.indd 3303_025_037_EN.indd 33 2/4/08 12:47:582/4/08 12:47:58
3/34
SYSTEM 27 Applications
c Opening for cable entry with TL cover.
c Double-insulation mounting.
c Excellent resistance to corrosive environments.
c Exterior hinges, allowing a door opening of approximately 180°.
c Removable blanking plate with a width of 36 mm (2 modules), standard
supply one per row.
c A lateral double bar lock CL-27 or key CLL-27 can be incorporated.
S27 DL/48
Modular PLS boxes composed of base and transparent low cover, with hinges and manually-operated and screwdriver-operated locks.DL incorporated chassis composed of automatic DIN-35 rails, insulated panel protector and neutral-earth terminal blocks of 2 × 16 + 5 × 6 mm2.
Insulating modular boxes with distribution chassis
03_025_037_EN.indd 3403_025_037_EN.indd 34 2/4/08 12:47:582/4/08 12:47:58
S27 DL/12
S27 DL/24
S27 DL/24-2
S27 DL/48
S27 DL/36
3/35
External dimensions (mm)
ReferenceTotal capacity in 18 mm
modulesNo. of rows Approx. weight (kg)
Height (A)
Width (B)
Depth (C)
180 270 180 S27 DL/12 12 1 1.7
270 270 180 S27 DL/24 24 2 2.5
360 270 180 S27 DL/24-2 24 2 2.7
360 270 180 S27 DL/36 36 3 2.8
540 270 180 S27 DL/48 48 4 3.8
ApplicationsSYSTEM 27
Dimensions (mm)
TABLE OF MODELS, DIMENSIONS AND REFERENCES
03_025_037_EN.indd 3503_025_037_EN.indd 35 2/4/08 12:47:592/4/08 12:47:59
3/36
SYSTEM 27 Applications
Blanking plate in self-extinguishing insulating material for total or partial coverage of the window for automatic switches.
c Easily cut to the desired size.
For the distribution in a single row of automatic switches with a total of 12 modules.
1 2
3 4
Blanking plate
No. of modules Reference Length (mm)
6 ATP6/DTM 108
24 ATP24/DTM 432
Cut to size ATP/UND 1100
Distribution bars
No. of barsNo. of poles
per barReference Figure No.
1 12 BDS 1/12 1
2 6 BDS 2/6 2
3 4 BDS 3/4 3
4 3 BDS 4/3 4
03_025_037_EN.indd 3603_025_037_EN.indd 36 2/4/08 12:48:022/4/08 12:48:02
3/37
03_025_037_EN.indd 3703_025_037_EN.indd 37 2/4/08 12:48:042/4/08 12:48:04
1 2 3 4 65
1112 10 9 8 7
3/38
POLYMEL polyester monobloc enclosures
5 Enclosure with a tempered glass transparent door, maintaining the IP66 and IK08 (5J) degrees of protection.
1 The built-in canopy protects the door and the sealing gasket.
9 Depth adjustable mounting plate supports with positions every 12.5 mm.
03_038_039.indd 3803_038_039.indd 38 21/2/08 10:23:1021/2/08 10:23:10
3/39
2 Wall fixing from the outside with stainless steel or polyester wall brackets.
3 The fixing strips, notched every 25 mm, located at the back of the enclosure allow direct attachment of mounting rails or other devices, thus reducing assembly time.
6 The lock system is located outside the sealed area to maintain the IP66 degree of protection.
4 Four moulded bosses on the inside of the door help to assemble accessories. For maximum usable space, the door has a grid pattern for centring components. Door opening more than 180°.
12 Self-ventilation windows at the rear of the enclosure.
10 Direct wall fixing with a plug to maintain the double insulation and watertightness.4 inserts at the back for fixing the mounting plate.
11 Reversible polyester internal door with grid pattern for industrial control.
7 Interior hinges fixed into the door. The built-inpolyurethane sealing gasket guarantees IP66.
8 Ventilation louvers provide natural ventilation of the interior of enclosure, thus preventing condensation.
03_038_039.indd 3903_038_039.indd 39 21/2/08 10:23:1221/2/08 10:23:12
3/40
POLYMEL Polyester enclosuresIP66 (EN 60529)
PLM-75 PLM-75/CME
Hot-press moulded fibreglass-reinforced polyester enclosure, in grey RAL-7032.
Construction specifications
c Body of one single piece: monobloc.
c Fully reversible.
c Intended for use in both indoor and outdoor environments.
c A wide range of accessories enabling use in distribution, control and
measurement panels for industrial and infrastructure facilities.
c Standard double bar lock or three-point lock with handle (without insert).
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and EN 62208.
c IP66 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 to +150 ºC.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.
03_040_050_EN.indd 4003_040_050_EN.indd 40 2/4/08 12:50:102/4/08 12:50:10
3/41
POLYMEL Polyester enclosuresIP66 (EN 60529)
* PLM-32 model in polycarbonate.
(1) Four-point locking system.
TABLE OF MODELS, DIMENSIONS AND REFERENCES
External dimensions (mm)
Plain Transparent door door
Plain door Mounting plates
Adjustable plate
support
Modular chassis
Internal door
No. of locks
Plain Transparent door door
Height(A)
Width(B)
Depth(C) Standard double bar lock
Three-point lock with handle (without insert)
Withinsulating mounting
plate MetalInsu-lating
Microper-forated Universal
310 215 160 PLM-32* PLM-32/KT* 1 - - PLM-32MB - - -
308 255 160 PLM-3025 PLM-3025/KT 2 - - PLM-3025MB -
430 330 200 PLM-43 PLM-43/KT 2 PLM-43/CME PLM-43 KT/CME PLM-43MB
530 430 200 PLM-54 PLM-54/KT 2 PLM-54/CME PLM-54 KT/CME PLM-54MB
647 436 250 PLM-64 PLM-64/KT 2 PLM-64/CME PLM-64 KT/CME PLM-64MB
747 536 300 PLM-75 PLM-75/KT 2 PLM-75/CME PLM-75 KT/CME PLM-75MB
847 636 300 PLM-86 PLM-86/KT 2 PLM-86/CME PLM-86 KT/CME PLM-86MB
1056 852 350 PLM-108 (1) PLM-108KT (1) 1 - - PLM-108MB
03_040_050_EN.indd 4103_040_050_EN.indd 41 2/4/08 12:50:132/4/08 12:50:13
3/42
PLM-32...108
PLM-3025
POLYMEL Polyester enclosuresIP66 (EN 60529)
Dimensions (mm)
5 C
N
HRJ
M8
M8
B
Ø 8
D
A E
G
I
F H
16
Q
ML
I
K
P
Ø 8
PLM-… ENCLOSURE DIMENSIONS (EXCEPT PLM-3025)
Reference PLM-...
32 43 54 64 75 86 108
A 310 430 530 647 747 847 1056
B 215 330 430 436 536 636 852
C 160 200 200 250 300 300 350
D 310 280 380 480 580 680 864
E 215 200 300 300 400 500 694
F 270 380 480 580 680 780 980
G 170 260 360 360 460 560 760
H 225 325 425 525 625 725 925
I 125 225 325 325 425 525 725
J 275 375 475 575 675 775 975
K 75 150 250 250 350 450 650
L 8 13 13 13 15 15 15
M 144 181 181 228 278 278 327
N 2.3 2.7 2.9 2.9 3 3 4
P 132 179 279 279 379 479 684
Q 129 168 168 212 261 261 304
R 186 247 347 388 487 587 776
03_040_050_EN.indd 4203_040_050_EN.indd 42 2/4/08 12:50:142/4/08 12:50:14
355 165
200405
800
130
200
160100
160100165
251
398/635148
185
3/43
For the protection of cabling of outdoor installations, distribution panels for campgrounds, leisure harbours, etc. at which it is necessary to maintain a distance between the installation and the floor. Manufactured with fibreglass-reinforced polyester.
c Steel frame for fixing to the floor.
c Easy installation.
c High impact resistance.
Floor fixing using a frame (1)
Fixing to the enclosure
Floor-mounting pillar
PLM-54 SFS/PLM
PLM-64
ReferenceFor attachment to enclosures
(1) Frame supplied
For the lateral or vertical coupling of two enclosures.
c Made of fibreglass-reinforced self-extinguishing polyester.
c Sealing gasket built in, which guarantees the IP66 degree of protection.
c Mounting with screws (included in the standard supply).
Enclosure fastening ties
PLM-75 y 86 lateral BU/PLM
PLM-108 lateral BU-108/PLM
ReferenceType of couplingFor attachment to enclosures
POLYMEL Composition accessories
03_040_050_EN.indd 4303_040_050_EN.indd 43 2/4/08 12:50:142/4/08 12:50:14
15H1
V2H2
V1
8*
* For PLM-32 modeland PFI/PLM
3/44
Plain polyester cable entry plates, with sealing gasket and fastening hardware.
Cable entry plate
PLM-75/86/108 TLA-4420
PLM-108 TLA-6420
ReferenceFor attachment to enclosures
Composition accessories
Wall fixing can be done directly by drilling the back of the enclosure or with the PF/PLM polyester brackets or PFI/PLM stainless steel brackets. The brackets are mounted from the exterior to the back of the enclosure, using inserts and M8 screws (included in the standard supply).
Model PLM-32 is mounted using self-tapping screws.
The fixing pieces can be positioned vertically or horizontally.
The set is not included in the standard supply of the enclosure.
PFI/PLM
PF/PLM PFI/PLM
Wall fixing
Insulated
For attachment to enclosures
Stainless steel
Reference Horizontal position Vertical position
Fixing centres (mm)
Height (H1) Width (H2) Height (V1) Width (V2)
PLM-32 PF/PLM-32 - 247 239 334 152
PLM-3025 PF/PLM - 275 355 410 220
PLM-43 PF/PLM PFI/PLM 355 360 490 225
PLM-54 PF/PLM PFI/PLM 455 460 590 325
PLM-64 PF/PLM PFI/PLM 555 465 690 330
PLM-75 PF/PLM PFI/PLM 655 565 790 430
PLM-86 PF/PLM PFI/PLM 755 665 890 530
PLM-108 PF/PLM PFI/PLM 955 885 1090 750
POLYMEL
03_040_050_EN.indd 4403_040_050_EN.indd 44 2/4/08 12:50:162/4/08 12:50:16
B
A
3/45
Composition accessories
Allows the enclosure to be fixed to concrete, wood or aluminium posts up to diameters of 675 mm.
c For exterior installations, provisional works or fairs, public lighting panels, etc.
c Galvanised steel fixing loop and profiles.
c Profiles attach to the back of the enclosure using M8 screws in the inserts (included in the standard supply).
c Recommended maximum weight of the installation: 100 kg.
Post fixing set
PLM-43 SFP-300
PLM-54 and PLM-64 SFP-400
PLM-75 SFP-500
PLM-86 SFP-600
PLM-108 SFP-800
ReferenceFor attachment to enclosures
Internal door set in fibre-glass reinforced polyester, except model PI-3025/PLM, made of sheet steel finished with polyester-epoxy RAL-7032 paint.
Insulating door specifications:
c Self-extinguishing.
c Grid pattern on the inside of the door for alignment of equipment.
c Quick locking through 1/4 turn sealable screws.
c Door opens in both directions.
C
D
* Plain internal door, dimensions A and B corresponding to the usable surface of the door.
Internal doors
PI-3025/PLM* 248 165 62 76
PIP-43 315 205 152 26
PIP-54 415 305 152 26
PIP-64 515 305 194 32
PIP-75 615 405 244 32
PIP-86 715 505 244 32
PIP-108 850 650 269 37
Reference A B C D
POLYMEL
03_040_050_EN.indd 4503_040_050_EN.indd 45 2/4/08 12:50:172/4/08 12:50:17
3/46
Doors to be changed or repositioned on PLM enclosures.
c Made of fibreglass-reinforced self-extinguishing polyester in grey RAL-7032.
c For maximum usable surface, the plain door has a grid pattern for centring components.
c Door opening to > 180°.
Spare doors
PLM-3025 PUPLM-3025 KTPLM-3025
PLM-43 PUPLM-43 KTPLM-43
PLM-54 PUPLM-54 KTPLM-54
PLM-64 PUPLM-64 KTPLM-64
PLM-75 PUPLM-75 KTPLM-75
PLM-86 PUPLM-86 KTPLM-86
PLM-108 PUPLM-108 KTPLM-108
TransparentPlain
For attachment to enclosuresType of door
Composition accessories
Locks up to PLM-86
Standard double bar lock, with zinc-alloy inserts, operation with LDB 5 or DBP wing key (conforming to DIN 43668).
Reference: CDB/PLM.
TRANSFORMING INSERT OF STANDARD LOCK INTO STANDARDISED VERSIONS
Specifications ReferenceType of key operation ref.
v 6 mm square lock LC-7 TC6/CRN
v 7 mm square lock LC-7 TC7/CRN
v 8 mm square lock LC-8 TC8/CRN
Triangle lock with ∆ 6.5 mm side LT-8 TT7/CRN
Triangle lock with ∆ 8 mm side LT-8 TT8/CRN
Handle lock with 405 key
TL/PLM
Handle lock with key 220
TL220/PM
Stainless steel padlocking
device (up to PLM 86) KPLM
Fixed wing lock CDB/PLM
Double bar wing
DBP
Locks for polyester enclosures
POLYMEL
03_040_050_EN.indd 4603_040_050_EN.indd 46 2/4/08 12:50:182/4/08 12:50:18
3/47
Composition accessories
Four-point locks for PLM-108
Standard double-bar lock for model PLM-108 in its plain door and KT transparent door versions. Operation with LDB 5 key or DBP wing key (conforming to DIN 43668).
TRANSFORMATION FROM FOUR-POINT LOCK TO DIFFERENT TYPES OF LOCKS OR FOR ENCLOSURES
Specifications ReferenceType of key operation ref.
v 6 mm square lock LC-7 TC 6/PL
v 7 mm square lock LC-7 TC 7/PL
v 8 mm square lock LC-8 TC 8/PL
Triangle lock with ∆ 7 mm side LT-8 TT 7/PL
Triangle lock with ∆ 8 mm side LT-8 TT 8/PL
Padlocking device BC/PL
STANDARD TRANSFORMATION FOR PLM-108 ENCLOSURE RETRACTABLE HANDLE LOCK WITH DIFFERENT TYPES
Specifications ReferenceType of key operation ref.
Double bar lock LDB 5 TEDB/PL
v 6 mm square lock LC-7 TEC 6/PL
v 7 mm square lock LC-7 TEC 7/PL
v 8 mm square lock LC-8 TEC 8/PL
Triangle lock with ∆ 7 mm side LT-8 TET 7/PL
Triangle lock with ∆ 8 mm side LT-8 TET 8/PL
Lock with key type 405 TEL/PL
Key-operated Lock
Reinforced type TER/PL
Lock with JIS key
TEL-JIS/PL
Lock with FAC key
TEL-FAC/PL
Manual lock TEM/PL
Handle without lock TE/PL
Padlocking device
BCME/PL
Handle for PLM-108 TEM/PL
LOCKS (INSERTS) FOR PLM...CME ENCLOSURES
Specifications ReferenceType of key operation ref.
Double bar lock LDB 5 TDB/PLD
Triangle lock with ∆ 8 mm side LT-8 TT7/PLD
Lock with key type 405 TCL/PLD
Key-operated Lock TLR/PLD
Reinforced type
Key-operated Lock
TJIS/PLD
Padlock lock
BCME/PL
Manual lock TEM/PLD
PLM... CME locks
POLYMEL
Standard handle locks without insert in models PLM… CME.
03_040_050_EN.indd 4703_040_050_EN.indd 47 2/4/08 12:50:212/4/08 12:50:21
3/48
For attachment to enclosures
Metal
Insulated
Perforated Universal
Bakelite Polyester
Height(A)
Width(B)
P S ReferenceThickness
(mm)Weight
(kg)Reference
Thickness(mm)
Weight(kg)
ReferenceThickness
(mm)Weight
(kg)Reference
Thickness(mm)
Weight(kg)
Reference D E
310 215 265 150 MM-32 2 0.6 MB-32 4 0.2 MP-32 4 0.3 MF-32 2 0.3 MR-32 255 154
308 255 265 200 MM-3025 2 0.6 MB-3025 4 0.3 MP-3025 4 0.4 MF-3025 2 0.5 MR-3025 253 228
430 330 365 250 MM-43 2 1.6 MB-43 4 0.5 MP-43 4 0.7 MF-43 2 1.5 MR-43 348 251
530 430 465 350 MM-54 2 2.5 MB-54 4 0.9 MP-54 4 1.2 MF-54 2 2.4 MR-54 450 351
647 435 565 350 MM-64 2 3.1 MB-64 4 1.1 MP-64 4 1.4 MF-64 2 3 MR-64 555 351
747 536 665 450 MM-75 2 4.6 MB-75 4 1.7 MP-75 4 2.1 MF-75 2 4.3 MR-75 645 451
847 636 765 550 MM-86 2.5 9.9 MB-86 4 2.3 MP-86 5 3.8 MF-86 2.5 9 MR-86 750 551
1056 812 965 750 MM-108 2.5 16.9 MB-108 5 5.7 MP-108 5 6.5 MF-108 2.5 16 MR-108 945 751
Mounting accessoriesPOLYMEL
A complete range of mounting plates comprised of 4 versions able to provide all the mountings required for this installation system.
c Metal plates of galvanised sheet steel.
c Microperforated plates made of galvanised sheet steel with 3.6 mm ∅ holes, 12.5 mm apart.
c Universal perforated plates for fast fixing of equipment, made of zinc steel.
c Insulating bakelite or polyester plates.
E
D
15
12,5
P
S
10,5 10,5
12,5 25 25
2525
20
B-75
A-7
5
ø6,5
ø8,5
P
S
12,5
P
S
B-75
A-7
5
12,5
12,5
12,5
12,5
ø3,6
P
S
Metal BakelitePerforated UniversalMetal
Bakelite
Microperforated
Universal perforated
Mounting plates
Polyester
Polyester
03_040_050_EN.indd 4803_040_050_EN.indd 48 2/4/08 12:50:262/4/08 12:50:26
B
A
1126 mm
30 30
1515
3/49
Mounting accessoriesPOLYMEL
Supports designed to fit 200, 250, 300 and 350 mm deep enclosures.
With positioning notches along its entire length for depth adjustment of the mounting plate every 12.5 mm.
c Made of galvanised sheet steel.
c Quick fixing to the enclosure.
Adjustable plate support
PLM-43 and 54 DPLM-200 156 94
PLM-64 DPLM-250 200 100
PLM-75 and 86 DPLM-300N 250 100
PLM-108 DPLM-350 306 106
For attachment to enclosures Reference A B
Fixing accessories for universal plates
Length(mm)
Fixing nut Fixing screw with washer
Thread typePackaging Packaging
M3 TFP 3 100 - - -
M4 TFP 4 100 TOR 10/4 A 10 100
TOR 16/4 A 16 100
M5 TFP 5 100
TOR 12/5 A 12 100
TOR 18/5 A 18 100
M6 TFP 6 100
TOR 12/6 A 12 100
TOR 18/6 A 18 100
03_040_050_EN.indd 4903_040_050_EN.indd 49 2/4/08 12:50:272/4/08 12:50:27
25
3/50
Mounting accessoriesPOLYMEL
c Insulating support and self-tapping screw for quick fixing of L brackets and 35 mm symmetrical rails (Ref. TCO/PLM).
c Insulating support and M6 inserted bolt for quick fixing of L brackets and 35 mm symmetrical rails (Ref. TCO-M6/PLM).
Rail fixing set
TCO/PLM Self-tapping
TCO-M6/PLM M6
Type of screwReference
35 mm symmetrical rails to support equipment, specially adapted to the width of the enclosures.
Fixing at the back of the enclosure using the TCO/PLM set.
35 mm symmetrical rail
PLM-32 CO-200/PLM 180
PLM-43 CO-300/PLM 280
PLM-54 and 64 CO-400/PLM 380
PLM-75 CO-500/PLM 480
PLM-86 CO-600/PLM 580
PLM-108 CO-800/PLM 795
For attachment to enclosures Reference Width
TCO/PLM
03_040_050_EN.indd 5003_040_050_EN.indd 50 2/4/08 12:50:292/4/08 12:50:29
3/51
Current distribution accessoriesPOLYMEL
Clip in fasteners to be installed directly on 19” racks and on slotted MR mounting plates.
Reference: GCR.
GCR ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Adjustable ties
White BlackL ∅
minimum∅
maximum
M
Reference Use
LZ25100 LN25100 100 2.5 1.6 22
LZ25200 LN25200 200 2.5 1.6 49
LZ35150 LN35150 150 3.5 1.6 35
LZ35200 LN35200 200 3.5 1.6 49
LZ35300 LN35300 300 3.5 1.6 75
LZ46150 LN46150 150 4.6 1.6 36
LZ46200 LN46200 200 4.6 1.6 49
LZ48270 LN48270 270 4.8 1.6 73
LZ46390 LN46390 390 4.6 1.6 109
LZ76390 LN76390 390 7.6 4.7 108
To tighten and cut to size the adjustable ties. They facilitate wiring and save time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the tool. Can be used on the following models of ties: LZ25100 up to LZ46390. Ref.: MARK20, 21.
Tightening tools
Reference
MARK3 2.5 ÷ 4.8
Admissible width ties
Reference
MARK20 2.5 ÷ 4.8
MARK21 4.6 ÷ 7.6
Admissible width ties
03_051_062_EN.indd 5103_051_062_EN.indd 51 2/4/08 12:51:542/4/08 12:51:54
3/52
Current distribution accessoriesPOLYMEL
To use with soft materials: 7 mm Ø hole, or hard materials: 8 mm Ø hole. Ties are attached up to 9 mm width. Material: black 6.6 nylon.
Ref.: LOK01.
Stud
To attach one or two ties, mounted with a single screw. Material: 6.6 nylon. Allows for attaching ties from the entire range.
Tie fixing support
Reference A B Fixing screwAdmissible width
tiesC
KR6 12 18 9 M4 2.5 ÷ 4.8
KR8 14.5 25 12 M6 2.5 ÷ 7.6
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to 3.2 mm thick. Material: 6.6 nylon.
Locking clips
Reference
SFC1 6 3.2 1
SFC2 6 1 2
FigureMax. panel
thickness mm∅ Perforation
mm
SFC2 SFC1
Fig. 1 Fig. 2
03_051_062_EN.indd 5203_051_062_EN.indd 52 2/4/08 12:51:552/4/08 12:51:55
adhesive support
3/53
Current distribution accessoriesPOLYMEL
To transform normal ties into ties with fixing heads, introduce a tie into this head before closing it on the cable bundle. Material: 6.6 nylon.
Support heads
Reference A B Fixing screwAdmissible width
tiesC
FH18 7.1 13.3 4 M4 2.5
FH30 9.5 17.9 4.7 M5 3.5
FH50 11.3 22.2 6.2 M6 4.7
Permits insertion of 1 tie from 4 points at a 90º angle. Attaches ties from the series LZ25100 up to LZ46390. Material: 6.6 nylon.
Self-adhesive support base
Reference A B C EAdmissible width
tiesD
MB3A 19.1 19.1 4.8 3.2 13.2 2.5 ÷ 3.5
MB4A 28.5 28.5 5.5 4 20.2 2.5 ÷ 4.8
To attach ties from any series. Material: 6.6 nylon.
Tie fixing support
Reference
LKC 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
03_051_062_EN.indd 5303_051_062_EN.indd 53 2/4/08 12:51:572/4/08 12:51:57
3/54
Current distribution accessoriesPOLYMEL
2 versions, fixed and graduated, ∅ from 5 to 25.4 mm. Material: black 6.6 nylon.
Fixing loop for tubes, hoses, etc.
Reference∅ A
min. - max.B D EC
NX1 5 3.5 1 6.2 13.7
NX3 8 3.9 1 9.4 20.5
NX5 12 3.9 1 9.4 24
NX8* 14.3 ÷ 15.8 4 1.3 12.6 32
NX11 17.4 ÷ 20 4 1.3 12.6 37
NX14 22.2 ÷ 25.4 4.3 1.5 16 45
*The NX8 model only has 3 adjustment holes.
NX 1-3-5 NX 8-11-14
Covers the head of the tie in its end, thus obtaining neater cabling. Material: 6.6 nylon.
Lateral tie fixing support
Reference
LKM/HE 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
03_051_062_EN.indd 5403_051_062_EN.indd 54 2/4/08 12:51:582/4/08 12:51:58
Ø A
Ø B
3/55
Current distribution accessoriesPOLYMEL
Insulating membrane glands made of PVC with entry that can be adjusted for cables.
Adjustable membrane glands
Reference Fig. Ø A Ø B* Ø C Ø D E FØ cable Tube
Capacity
ECPC-3 1 25 21.5 18 5 3.2 13 5 to 18 Pg 9 to 11
ECPC-5 1 33 29.5 26 5 3.2 20 5 to 26 Pg 9 to 16
ECPC-6 1 43 38.5 36 5 3.2 22 5 to 36 Pg 9 to 21
ECPC-9 2 70 63 60 28 3 20 28 to 60 Pg 21 to 48
ECPC-15 2 98 90 87 28 3 23 28 to 87 Pg 21 to 48
* Mounting perforation.
Fig. 1 Fig. 2
Small protective sleeves for cables coming out of tubes, as indicated in the instructions for MI BT 019. Made of flexible and durable PVC, in light grey colour.
Protective sleeves
Reference A Ø B Tube
PC-1 15.2 12.7 Pg 9
PC-2 18.6 16 Pg 11
PC-3 20.4 17.8 Pg 13.5
PC-4 22.5 19.8 Pg 16
PC-5 28.3 25.3 Pg 21
PC-6 37 33.6 Pg 29
PC-7 47 43 Pg 36
03_051_062_EN.indd 5503_051_062_EN.indd 55 2/4/08 12:51:592/4/08 12:51:59
3/56
Current distribution accessoriesPOLYMEL
Øexterior
SteelFlexible
steelPVC Insert Thread
Protective sleeves
Adjustable membrane
glandsPlain plugs
Adjustable membrane glands
Flexible steel with
PVC
Cables inserted*Ø interior To the perforationsTo the tubes
4 EC-1 to EC-7
Pg 9 15.2 12.7 12.4 12 11.1 6 2.5 - - 16 14 ECPC-3 to ECPC-6 PC-1 - -
ECN-5 to ECN-10
10 4 2.5 EC-2 to EC-7 EC-1
Pg 11 18.6 16 15.5 14.5 14.2 16 6 4 2.5 19 17.5 ECPC-5; ECPC-6 PC-2 EC-2 TC-1
25 ECN-5 to ECN-10 ECN-1
EC-3 to EC-7 EC-3
Pg 13.5 20.4 17.8 17.5 16.3 16 35 10 6 4 21 19.5 ECPC-5; ECPC-6 PC-3 ECPC-3 TC-2
ECN-5 to ECN-10
EC-4 to EC-7
Pg 16 22.5 19.8 18.7 18.5 17.6 50 16 10 6 23 21.5 ECPC-5; ECPC-6 PC-4 EC-4 TC-3
ECN-5 to ECN-10
EC-5 to EC-7 EC-5
Pg 21 28.3 25.3 24.7 23 23 70 25 16 10 29 27 ECPC-6 to ECPC-15 PC-5 ECPC-5 TC-4
ECN-6 to ECN-10 ECN-5
95 35 25 16 EC-6; EC-7 EC-6 TC-5
Pg 29 37 33.6 33.5 31 31 120 50 35 25 38 35.5 ECPC-9; ECPC-15 PC-6 ECPC-6 TCP-5
150 ECN-7; ECN-10 ECN-6
185 35 EC-7 EC-7
Pg 36 47 43 41.5 41 40.3 240 70 50 50 48 45.5 ECPC-9; ECPC-15 PC-7 ECN-7 TC-6
300 ECN-10
95 70 ECPC-9; ECPC-15
Pg 42 54 50 48 48 47 - 120 95 70 55 52.5 ECN-10 - - -
120 95 ECPC-9; ECPC-15
Pg 48 60 56 54.2 52.5 51.4 - 150 150 120 61 58 ECN-10 - - -
* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).
1 2 3 4
MODELS, DIMENSIONS AND REFERENCES
No. of conductors
Tubes HIMEL accessories to be coupled
Useful information about Pg tubes and HIMEL accessories to be coupled
Ø perforations to
Desig-nation
03_051_062_EN.indd 5603_051_062_EN.indd 56 2/4/08 12:52:002/4/08 12:52:00
3/57
Current distribution accessoriesPOLYMEL
Base of safety terminals made of black matte self-extinguishing polyamide-6; terminal of brass MS-58.
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that spreads the pressure out throughout the entire contact surface, avoiding the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the pressure exerted by the conductors cannot open the terminal and loosen the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap, avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of strips of any length. Service voltage: 500 V.
Sigma safety terminals
Reference
S.04 1 × 4 30 20 13 21 4
S.06 1 × 6 33 25 16 24 7
S.10 1 × 10 38 28 16 28 6
S.16 1 × 16 42 32 19 32 9
S.25/35 1 × 35 46 38 23 34 11
S.50 1 × 50 52 45 27 40 15
S.70 1 × 70 55 50 30 40 15
S.95/100 1 × 100 58 54 33 40 20
NOTE: each terminal accepts up to 2 conductors of the section indicated.
Section m/m2 A B C D E
* Included in standard supply.
Number of terminals section in mm2
Earth and neutral bypass terminal blocks with insulated plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Bypass terminal blocks
RBLZ/21656* 216 mm2 + 56 mm2
RBLZ/21686 216 mm2 + 86 mm2
RBLZ/216146 216 mm2 + 146 mm2
RBLZ/216296 216 mm2 + 296 mm2
Reference
03_051_062_EN.indd 5703_051_062_EN.indd 57 2/4/08 12:52:002/4/08 12:52:00
1 2
3/58
Current distribution accessoriesPOLYMEL
Terminals especially designed for branching cables on plates; their main application is busbar connection.
BBH terminals are made of a tinned, hot cast copper alloy and are suitable for connecting to a conductor of copper or aluminium indistinctly (bimetal).
Bimetal BBH terminals
Reference
BBH-29 6-50 -
BBH-29C* 6-50 -
BBH-30 10-95 -
BBH-31 16-150 -
BBH-32 50-240 -
BBH-29D 6-50 6-50
BBH-29DC* 6-50 6-50
BBH-30D 10-95 10-95
BBH-31D 25-150 16-150
BBH-32D 95-240 5-240
Main section mm2 Bypass section mm2
Reference
BBH-29P 6-50 -
BBH-29PC* 6-50 -
BBH-29DP 6-50 6-50
BBH-29DPC* 6-50 6-50
* Include terminal cover CBBH-29.
Main section mm2 Bypass section mm2
BBH-29 BBH-29D
BBH-29P BBH-29DP
Plate entry and bypass by cable.
Plate/cable terminals
ReferenceCable bypass section
(mm2)Plate thickness (mm) Figure
BPCH 516 1.5 to 16 5 2
BPCH 550 1.5 to 50 5 2
BPCH 5120 16 to 120 5 2
BPCH 1016 1.5 to 16 10 1
BPCH 1050 1.5 to 50 10 1
BPCH 10120 16 to 120 10 1
03_051_062_EN.indd 5803_051_062_EN.indd 58 2/4/08 12:52:042/4/08 12:52:04
35590
7066
3/59
Lighting accessoriesPOLYMEL
Compact lamp
Specifications TensionPlugReference
Lamp fixed with a magnet or
on 35 mm symmetric LAM-75 220 V/16 A 220 V/50 Hz
DIN rail.
Lamp fixed on a 35 mm
symmetric DIN rail. LAC-75 220 V/16 A 220 V/50 Hz
Lamp fixed with a magnet
or on 35 mm symmetric LAM-75/120 120 V/15 A 120 V/60 Hz
DIN rail.
Lamp fixed on a 35 mm
symmetric DIN rail. LAC-75/120 120 V/15 A 120 V/60 Hz
Compact fluorescent lamps, designed especially for use in electronic enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.
c 200 V/16 A socket with earthing.
c Maximum ambient temperature 60 °C.
c Lighting output = 75 W bulb.
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm.
c Lifespan: 10000 h.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Slimline lamp
Reference Plug Socket Approval
LAMS75 AC 230 V/16 A SCHUKO VDE
LAMX75 AC 230 V/- - VDE
LAMU75 AC 120 V/15 A USA UL
03_051_062_EN.indd 5903_051_062_EN.indd 59 2/4/08 12:52:062/4/08 12:52:06
396
67
100
500
3/60
Lighting accessoriesPOLYMEL
Dual lamp
1
2
3
4
Specifications Support fixing Figure Reference Tension
Motion-activated
Magnetic, using screws LAMDP 220 V/56 Hz
and/or (1) 35 DIN rail 1 LAMDP 120 120 V/60 Hz
On/off switch with the possibility Magnetic, using screws LAMIN 220 V/50 Hz
of connection of door switch and/or (1) 35 DIN rail 2 LAMIN 120 120 V/60 H
Mobile lamp, connection Adhesive or screws
LAMPO 220 V/50 Hz
via cable 3 LAMPO 120 120 V/60 Hz
Support for LAMDP, LAMIN, Adhesive or screws
LAMPO lamp 4 SOLAM
(1) DIN rail not provided.
Light fixtures designed especially for use in electronic enclosures with various possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or 120 V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model via cable.
c Degree of protection IP20.
c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
c Connection/disconnection switch.
c Terminal connection entry.
Incandescent lamp
Reference
LAI/OL 68
03_051_062_EN.indd 6003_051_062_EN.indd 60 2/4/08 12:52:072/4/08 12:52:07
3/61
Natural ventilation accessoriesPOLYMEL
To connect the inside of the enclosure with the exterior atmosphere and prevent condensation. Can be fixed onto the outside, Ref.: VM-25 and VM-27 or onto the internal sides connected with the rear self-ventilating windows of the POLYMEL enclosures, Ref.: VM-35.
VM-25 VM-27
VM-35
Ventilation devices
VM-25 For coupling to the outside of all polyester enclosures
VM-27
VM-35 For coupling to the interior of POLYMEL enclosures
SpecificationsReference
To remove condensation water.
Mounted on the ∅ 9 mm housing on the inside of the bottom of the enclosure. Degree of protection IP55.
Purging device
VEA-9 For attachment to all enclosures
SpecificationsReference
Rear blanking plates in insulating material to protect against unwanted elements entering into the self-ventilating window of the enclosure.
Not included in standard supply with the enclosure except for model 108 which has it built in.
Rear blanking plates
PLM-32 CE-PLM/A
PLM-43 and 54 CE-PLM/B
PLM-64, 75 and 86 CE-PLM/C
ReferenceFor attachment to enclosures
03_051_062_EN.indd 6103_051_062_EN.indd 61 2/4/08 12:52:092/4/08 12:52:09
174
188 22 278 40
234
3/62
Complementary accessoriesPOLYMEL
Dodge-type brass nuts designed to be incorporated into the bosses of PLM enclosures.
Expandable nuts
M5 PLM-43 and 54 TEX 5
M6 PLM-64 and 108 TEX 6
M8 For the back of the enclosure TEX 8
ReferenceSpecifications For attachment to enclosures
PP-A models made of thermo-plastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding A4 or A5-sized plans.
Document pocket
Ref.: PP-A5 Ref.: PP-A4
Plan size
A4 PP-A4
A5 PP-A5
Reference
Insulated
TEX 8 TEX 6 TEX 5
03_051_062_EN.indd 6203_051_062_EN.indd 62 2/4/08 12:52:102/4/08 12:52:10
3/63
c Rigid structure made of galvanised steel.
c Insulating cover and frame in self-extinguishing material in RAL-7035.
Quick mounting, without the need for screws.
c System for identifying circuits included in the standard supply.
c Earth and neutral bypass terminal blocks. Ref.: RBLZ/21656 (included in
standard supply).
PLM-64/KT + DLA-48P
POLYMEL Applications
Distribution chassis set for modular equipment, Ref.: DLA-... with a distance between the 35 mm symmetric profile and the cover, which is adjustable as needed by the customer from 40 to 85 mm.
Dinimel DLA distribution chassis
03_063_067_EN.indd 6303_063_067_EN.indd 63 2/4/08 12:52:592/4/08 12:52:59
3/64
* Models DLA-48P, 66, 88, 84 and 112.
POLYMEL Applications
Dimensions (mm)
DLA-24 DLA-48 DLA-48P DLA-66 DLA-88
DLA-84 DLA-112 DLA-240
* For PLM.../CME enclosures with three-point locks, factory assembly
To be coupled to enclosures*
Reference
Plain door Transparent door No. of rowsQuantity
No. of 18 mm modules
Distribution of rows
Automatic rail
No. of plates A B
Dimensions
C D min. E min.
PLM-3025 PLM-3025/KT DL/PLM18 2 2 18 - - - - - -
PLM-43 PLM-43/KT DLA-24 2 2 24 - 216 115 137 38 88
PLM-54 PLM-54/KT DLA-48 3 3 48 - 288 90 112 38 88
PLM-64 PLM-64/KT DLA-48P 3 3 48 - 288 140 170 80 130
PLM-75 PLM-75/KT DLA-66 4 3 66 1 395 115 145 129 179
PLM-75 PLM-75/KT DLA-88 4 4 88 - 395 115 145 129 179
PLM-86 PLM-86/KT DLA-84 4 3 84 1 504 165 195 129 179
PLM-86 PLM-86/KT DLA-112 4 4 112 - 504 165 195 129 179
PLM-108 PLM-108/KT DLA-240 6 6 234 - 704 115 146 170 220
03_063_067_EN.indd 6403_063_067_EN.indd 64 2/4/08 12:53:002/4/08 12:53:00
3/65
Insulating cover in self-extinguishing material in RAL-7035 to protect non-modular equipment. Height: 150 mm (1 row).
Plain Dinimel DLA cover
DLA-24 CTL300/DLA 256
DLA-48 and 48P CTL400/DLA 356
DLA-66 and 88 CTL500/DLA 456
DLA-84 and 112 CTL600/DLA 555
DLA-240 CTL800/DLA 755
ReferenceReferenceTo be coupled to chassis
POLYMEL Applications
Mounting plate in galvanised steel for fixing non-modular equipment. Height: 150 mm (1 row).
Dinimel DLA mounting plate
DLA-24 PMP300/DLA 215
DLA-48 and 48P PMP400/DLA 315
DLA-66 and 88 PMP500/DLA 415
DLA-84 and 112 PMP600/DLA 514
DLA-240 PMP800/DLA 714
WidthReferenceTo be coupled to chassis
Blanking plate of self-extinguishing insulating material for total or partial coverage of the windows for automatic switches. Easily cut to the desired size.
Blanking plate
ATP6/DTM 108 6
ATP24/DTM 432 24
ATP/UND 1100 Cut to size
No. of modulesLength (mm)Reference
03_063_067_EN.indd 6503_063_067_EN.indd 65 2/4/08 12:53:012/4/08 12:53:01
3/66
* Included in standard supply.
Number of terminals 3 section in mm2
Earth and neutral bypass terminal blocks with insulating plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Bypass terminal blocks
RBLZ/21656* 216 mm2 + 56 mm2
RBLZ/21686 216 mm2 + 86 mm2
RBLZ/216146 216 mm2 + 146 mm2
RBLZ/216296 216 mm2 + 296 mm2
Reference
POLYMEL Applications
For the distribution in a single row of automatic switches with a total of 12 modules.
1 2
3 4
Distribution bars
No. of bars No. of poles per bar Reference Figure No.
1 12 BDS 1/12 1
2 6 BDS 2/6 2
3 4 BDS 3/4 3
4 3 BDS 4/3 4
03_063_067_EN.indd 6603_063_067_EN.indd 66 2/4/08 12:53:012/4/08 12:53:01
3/67
POLYMEL Applications
Due to the quality of the plastic materials and their constructive characteristics, POLYMEL enclosures are suitable for panels in installations subjected to contact with chemical agents and harsh environments, usually, for example, in the petrochemical, cement making, etc. industries.
Their resistance to corrosion and UV rays permits POLYMEL enclosures to be adapted to panels in exterior installations subjected to long exposures to the sun: winter sport stations, installations close to the sea, etc.
POLYMEL enclosures in leisure facilities
Their high degree of protection (IP66) and their high resistance to impacts and temperature make POLYMEL enclosures particularly ideal for industrial installations subjected to processes with frequent water projection, such as the paper-making and agri-food industries or automobile washes.
POLYMEL enclosures in interior industrial installations
POLYMEL enclosures in exterior industrial installations
03_063_067_EN.indd 6703_063_067_EN.indd 67 2/4/08 12:53:052/4/08 12:53:05
1 2 3 4 5 6 7
10 814 13 12 11 9
3/68
5 Detail of fixing the glass to the inside of the door.
1 Wall fixing brackets.
PLA polyester modular enclosures
8 Detail of bosses on the doors, back and lower part of the enclosure for fixing of various materials.
12 Mounting plate fixing support, adjustable every 25 mm.
03_068_069.indd 6803_068_069.indd 68 22/2/08 18:35:3022/2/08 18:35:30
3/69
7 The locking system is outside the sealed area, which guarantees the IP over time. Handle lock with detail of the cover that hides the lock device.
6 Ribbed door to make fixing of posters difficult. Likewise, this uneven surface makes the door thicker and also improves the robustness of the enclosure.
4 Detail of 120º hinge with easily removable stainless steel safety pin. Seal that guarantees IP65 watertightness.
3 The enclosures with canopies allow self-ventilation of the enclosure, preventing condensation and maintaining the IP54.
2 2-point locking system (up to 750 mm height) or 4-point locking system (from 1,000 mm height).
11 Door retainer.
14 Metal, insulating or universal mounting plates to be fixed directly to the back of the enclosure or by using adjustable supports.
10 Door opening to 180º, which improves accessibility to the interior of the enclosure with plinth and canopy. The plinth-type base allows direct floor fixing.
9 Anti-vandalism reinforcement.
13 PLAZ... enclosures with open plinth-type bottom for easy cable entry.
03_068_069.indd 6903_068_069.indd 69 22/2/08 18:35:3222/2/08 18:35:32
3/70
CONSTRUCTION SYSTEMS
PLA 1054 PLA 1054 T PLAZ 1054 PLAZ 1054 T
PLA 1054 KT PLA 1054 TKT PLAZ 1054 KT PLAZ 1054 TKT
PLA 1054 R PLA 1054 TR PLAZ 1054 R PLAZ 1054 TR
PLA 1054 P PLA 1054 TP PLAZ 1054 P PLAZ 1054 TP
PLA 1054 PKT PLA 1054 TPKT PLAZ 1054 PKT PLAZ 1054 TPKT
PLA 1273 PR PLA 1273 TPR PLAZ 1273 PR PLAZ 1273 TPR
Plain doorPLA/PLAZ...
Transparent doorPLA/PLAZ...KT
Ribbed doorPLA/PLAZ...R
Plain front andback doorsPLA/PLAZ...P
Transparent front door andplain back doorPLA/PLAZ...PKT
Ribbed front and back doorsPLA/PLAZ...PR
Closed topSelf-ventilated top with
canopy
Enclosures with open plinth-type baseEnclosures with closed baseTable of formation references
General table with the construction systems on the horizontal axis and the various versions of doors on the vertical axis, offering apanoramic view of the formation of all the possibilities of references.
Closed topSelf-ventilated top with
canopy
PLA... PLA...T PLAZ... PLAZ...T
120° 120°
IP65
Door opening
Degree of protection IP54
120°
IP54
180°
IP54
EXAMPLES OF FORMING REFERENCES
Height: 1,000 Width: 500 Depth: 420
Top and bottom closed, with transparent door.
Ref.: PLA 1054 KT
Height: 1,200 Width: 750 Depth: 320
Self-ventilated top with canopy, open plinth-type bottom, ribbed front and back doors.
Ref.: PLA Z 1273 TPR
With base
Construction systems
Dimensions (mm)
Closed Open, plinth-type Height Width DepthExamples of enclosures
PLA -
- PLAZ XX XX X
PLA - 10 5 4
- PLAZ 12 7 3
03_070_083_EN.indd 7003_070_083_EN.indd 70 5/3/08 11:20:505/3/08 11:20:50
3/71
The table showing each of the dimensions (height, width and depth) determines the digits to use when forming the references.The tables in grey and blue have to do with to the examples of the reference formation table.
Height Width Depth
Nominal dimensions (mm)
5 00
5 00
7 50 3 20
7 50
10 00
10 00
12 50 4 20
12 50
15 00
Door versionWith top
ClosedSelf-ventilatedwith canopy Plain Transparent Ribbed Plain front cover and back Ribbed front cover and back
- T - KT R P PR
- - - KT - - -
- T - - - - PR
03_070_083_EN.indd 7103_070_083_EN.indd 71 5/3/08 11:20:525/3/08 11:20:52
3/72
Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120º, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to 750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow direct fixing of mounting plates and/or the desired installation system, accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and EN 62208.
c IP65 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and EN 62262).
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 to +150 ºC.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.
PLA 1253
PLA . . . Polyester enclosures completely closedIP65 (EN 60529)
PLA 12123
Hot-press moulded fibreglass-reinforced polyester enclosures, in grey RAL-7032 (able to withstand weather conditions).
03_070_083_EN.indd 7203_070_083_EN.indd 72 5/3/08 11:20:535/3/08 11:20:53
3/73
PLA. . . Completely closed polyester enclosuresIP65 (EN 60529)
Basic composition
c Enclosure with top and base completely closed.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to mechanical impacts IK08 (5J) conforming to EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with “anti-lever” hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm height.
c Standard double bar lock, operated by key LDB5.
c Two-door enclosures have a central profile.
SELECTION TABLE FOR CLOSED POLYESTER ENCLOSURES
Height Width Depth No. of doors
Nominal dimensions (mm)
500 500 320 1 PLA 553 PLA 553 R PLA 553 KT PLA 553 P PLA 553 PR PLA 553 PKT
420 1 PLA 554 PLA 554 R PLA 554 KT PLA 554 P PLA 554 PR PLA 554 PKT
750 320 1 PLA 573 PLA 573 R PLA 573 KT PLA 573 P PLA 573 PR PLA 573 PKT
420 1 PLA 574 PLA 574 R PLA 574 KT PLA 574 P PLA 574 PR PLA 574 PKT
1000 320 2 PLA 5103 PLA 5103 R PLA 5103 KT PLA 5103 P PLA 5103 PR PLA 5103 PKT
420 2 PLA 5104 PLA 5104 R PLA 5104 KT PLA 5104 P PLA 5104 PR PLA 5104 PKT
1250 320 2 PLA 5123 PLA 5123 R PLA 5123 KT PLA 5123 P PLA 5123 PR PLA 5123 PKT
420 2 PLA 5124 PLA 5124 R PLA 5124 KT PLA 5124 P PLA 5124 PR PLA 5124 PKT
750 500 320 1 PLA 753 PLA 753 R PLA 753 KT PLA 753 P PLA 753 PR PLA 753 PKT
420 1 PLA 754 PLA 754 R PLA 754 KT PLA 754 P PLA 754 PR PLA 754 PKT
750 320 1 PLA 773 PLA 773 R PLA 773 KT PLA 773 P PLA 773 PR PLA 773 PKT
420 1 PLA 774 PLA 774 R PLA 774 KT PLA 774 P PLA 774 PR PLA 774 PKT
1000 320 2 PLA 7103 PLA 7103 R PLA 7103 KT PLA 7103 P PLA 7103 PR PLA 7103 PKT
420 2 PLA 7104 PLA 7104 R PLA 7104 KT PLA 7104 P PLA 7104 PR PLA 7104 PKT
1250 320 2 PLA 7123 PLA 7123 R PLA 7123 KT PLA 7123 P PLA 7123 PR PLA 7123 PKT
420 2 PLA 7124 PLA 7124 R PLA 7124 KT PLA 7124 P PLA 7124 PR PLA 7124 PKT
1000 500 320 1 PLA 1053 PLA 1053 R PLA 1053 KT PLA 1053 P PLA 1053 PR PLA 1053 PKT
420 1 PLA 1054 PLA 1054 R PLA 1054 KT PLA 1054 P PLA 1054 PR PLA 1054 PKT
750 320 1 PLA 1073 PLA 1073 R PLA 1073 KT PLA 1073 P PLA 1073 PR PLA 1073 PKT
420 1 PLA 1074 PLA 1074 R PLA 1074 KT PLA 1074 P PLA 1074 PR PLA 1074 PKT
1000 320 2 PLA 10103 PLA 10103 R PLA 10103 KT PLA 10103 P PLA 10103 PR PLA 10103 PKT
420 2 PLA 10104 PLA 10104 R PLA 10104 KT PLA 10104 P PLA 10104 PR PLA 10104 PKT
1250 320 2 PLA 10123 PLA 10123 R PLA 10123 KT PLA 10123 P PLA 10123 PR PLA 10123 PKT
420 2 PLA 10124 PLA 10124 R PLA 10124 KT PLA 10124 P PLA 10124 PR PLA 10124 PKT
1250 500 320 1 PLA 1253 PLA 1253 R PLA 1253 KT PLA 1253 P PLA 1253 PR PLA 1253 PKT
420 1 PLA 1254 PLA 1254 R PLA 1254 KT PLA 1254 P PLA 1254 PR PLA 1254 PKT
750 320 1 PLA 1273 PLA 1273 R PLA 1273 KT PLA 1273 P PLA 1273 PR PLA 1273 PKT
420 1 PLA 1274 PLA 1274 R PLA 1274 KT PLA 1274 P PLA 1274 PR PLA 1274 PKT
1000 320 2 PLA 12103 PLA 12103 R PLA 12103 KT PLA 12103 P PLA 12103 PR PLA 12103 PKT
420 2 PLA 12104 PLA 12104 R PLA 12104 KT PLA 12104 P PLA 12104 PR PLA 12104 PKT
1250 320 2 PLA 12123 PLA 12123 R PLA 12123 KT PLA 12123 P PLA 12123 PR PLA 12123 PKT
420 2 PLA 12124 PLA 12124 R PLA 12124 KT PLA 12124 P PLA 12124 PR PLA 12124 PKT
1500 500 320 1 PLA 1553 PLA 1553 R PLA 1553 KT PLA 1553 P PLA 1553 PR PLA 1553 PKT
420 1 PLA 1554 PLA 1554 R PLA 1554 KT PLA 1554 P PLA 1554 PR PLA 1554 PKT
750 320 1 PLA 1573 PLA 1573 R PLA 1573 KT PLA 1573 P PLA 1573 PR PLA 1573 PKT
420 1 PLA 1574 PLA 1574 R PLA 1574 KT PLA 1574 P PLA 1574 PR PLA 1574 PKT
1000 320 2 PLA 15103 PLA 15103 R PLA 15103 KT PLA 15103 P PLA 15103 PR PLA 15103 PKT
420 2 PLA 15104 PLA 15104 R PLA 15104 KT PLA 15104 P PLA 15104 PR PLA 15104 PKT
1250 320 2 PLA 15123 PLA 15123 R PLA 15123 KT PLA 15123 P PLA 15123 PR PLA 15123 PKT
420 2 PLA 15124 PLA 15124 R PLA 15124 KT PLA 15124 P PLA 15124 PR PLA 15124 PKT
03_070_083_EN.indd 7303_070_083_EN.indd 73 5/3/08 11:20:555/3/08 11:20:55
3/74
Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120º, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to 750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow direct fixing of mounting plates and/or the desired installation system, accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 to +150 ºC.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.
PLA. . .TPolyester enclosures with self-ventilated top with canopy and closed baseIP54 (EN 60529)
Hot-press moulded, fibreglass-reinforced, self-ventilated polyester enclosures, in grey RAL-7032 (able to withstand weather conditions).
PLA 1253T
03_070_083_EN.indd 7403_070_083_EN.indd 74 5/3/08 11:20:565/3/08 11:20:56
3/75
PLA. . .TPolyester enclosures with self-ventilated top with canopy and closed baseIP54 (EN 60529)
SELECTION TABLE FOR CLOSED BASE, SELF-VENTILATED POLYESTER ENCLOSURES
Height Width Depth No. of doors
Nominal dimensions (mm)
500 500 320 1 PLA 553 T PLA 553 TR PLA 553 TKT PLA 553 TP PLA 553 TPR PLA 553 TPKT
420 1 PLA 554 T PLA 554 TR PLA 554 TKT PLA 554 TP PLA 554 TPR PLA 554 TPKT
750 320 1 PLA 573 T PLA 573 TR PLA 573 TKT PLA 573 TP PLA 573 TPR PLA 573 TPKT
420 1 PLA 574 T PLA 574 TR PLA 574 TKT PLA 574 TP PLA 574 TPR PLA 574 TPKT
1000 320 2 PLA 5103 T PLA 5103 TR PLA 5103 TKT PLA 5103 TP PLA 5103 TPR PLA 5103 TPKT
420 2 PLA 5104 T PLA 5104 TR PLA 5104 TKT PLA 5104 TP PLA 5104 TPR PLA 5104 TPKT
1250 320 2 PLA 5123 T PLA 5123 TR PLA 5123 TKT PLA 5123 TP PLA 5123 TPR PLA 5123 TPKT
420 2 PLA 5124 T PLA 5124 TR PLA 5124 TKT PLA 5124 TP PLA 5124 TPR PLA 5124 TPKT
750 500 320 1 PLA 753 T PLA 753 TR PLA 753 TKT PLA 753 TP PLA 753 TPR PLA 753 TPKT
420 1 PLA 754 T PLA 754 TR PLA 754 TKT PLA 754 TP PLA 754 TPR PLA 754 TPKT
750 320 1 PLA 773 T PLA 773 TR PLA 773 TKT PLA 773 TP PLA 773 TPR PLA 773 TPKT
420 1 PLA 774 T PLA 774 TR PLA 774 TKT PLA 774 TP PLA 774 TPR PLA 774 TPKT
1000 320 2 PLA 7103 T PLA 7103 TR PLA 7103 TKT PLA 7103 TP PLA 7103 TPR PLA 7103 TPKT
420 2 PLA 7104 T PLA 7104 TR PLA 7104 TKT PLA 7104 TP PLA 7104 TPR PLA 7104 TPKT
1250 320 2 PLA 7123 T PLA 7123 TR PLA 7123 TKT PLA 7123 TP PLA 7123 TPR PLA 7123 TPKT
420 2 PLA 7124 T PLA 7124 TR PLA 7124 TKT PLA 7124 TP PLA 7124 TPR PLA 7124 TPKT
1000 500 320 1 PLA 1053 T PLA 1053 TR PLA 1053 TKT PLA 1053 TP PLA 1053 TPR PLA 1053 TPKT
420 1 PLA 1054 T PLA 1054 TR PLA 1054 TKT PLA 1054 TP PLA 1054 TPR PLA 1054 TPKT
750 320 1 PLA 1073 T PLA 1073 TR PLA 1073 TKT PLA 1073 TP PLA 1073 TPR PLA 1073 TPKT
420 1 PLA 1074 T PLA 1074 TR PLA 1074 TKT PLA 1074 TP PLA 1074 TPR PLA 1074 TPKT
1000 320 2 PLA 10103 T PLA 10103 TR PLA 10103 TKT PLA 10103 TP PLA 10103 TPR PLA 10103 TPKT
420 2 PLA 10104 T PLA 10104 TR PLA 10104 TKT PLA 10104 TP PLA 10104 TPR PLA 10104 TPKT
1250 320 2 PLA 10123 T PLA 10123 TR PLA 10123 TKT PLA 10123 TP PLA 10123 TPR PLA 10123 TPKT
420 2 PLA 10124 T PLA 10124 TR PLA 10124 TKT PLA 10124 TP PLA 10124 TPR PLA 10124 TPKT
1250 500 320 1 PLA 1253 T PLA 1253 TR PLA 1253 TKT PLA 1253 TP PLA 1253 TPR PLA 1253 TPKT
420 1 PLA 1254 T PLA 1254 TR PLA 1254 TKT PLA 1254 TP PLA 1254 TPR PLA 1254 TPKT
750 320 1 PLA 1273 T PLA 1273 TR PLA 1273 TKT PLA 1273 TP PLA 1273 TPR PLA 1273 TPKT
420 1 PLA 1274 T PLA 1274 TR PLA 1274 TKT PLA 1274 TP PLA 1274 TPR PLA 1274 TPKT
1000 320 2 PLA 12103 T PLA 12103 TR PLA 12103 TKT PLA 12103 TP PLA 12103 TPR PLA 12103 TPKT
420 2 PLA 12104 T PLA 12104 TR PLA 12104 TKT PLA 12104 TP PLA 12104 TPR PLA 12104 TPKT
1250 320 2 PLA 12123 T PLA 12123 TR PLA 12123 TKT PLA 12123 TP PLA 12123 TPR PLA 12123 TPKT
420 2 PLA 12124 T PLA 12124 TR PLA 12124 TKT PLA 12124 TP PLA 12124 TPR PLA 12124 TPKT
1500 500 320 1 PLA 1553 T PLA 1553 TR PLA 1553 TKT PLA 1553 TP PLA 1553 TPR PLA 1553 TPKT
420 1 PLA 1554 T PLA 1554 TR PLA 1554 TKT PLA 1554 TP PLA 1554 TPR PLA 1554 TPKT
750 320 1 PLA 1573 T PLA 1573 TR PLA 1573 TKT PLA 1573 TP PLA 1573 TPR PLA 1573 TPKT
420 1 PLA 1574 T PLA 1574 TR PLA 1574 TKT PLA 1574 TP PLA 1574 TPR PLA 1574 TPKT
1000 320 2 PLA 15103 T PLA 15103 TR PLA 15103 TKT PLA 15103 TP PLA 15103 TPR PLA 15103 TPKT
420 2 PLA 15104 T PLA 15104 TR PLA 15104 TKT PLA 15104 TP PLA 15104 TPR PLA 15104 TPKT
1250 320 2 PLA 15123 T PLA 15123 TR PLA 15123 TKT PLA 15123 TP PLA 15123 TPR PLA 15123 TPKT
420 2 PLA 15124 T PLA 15124 TR PLA 15124 TKT PLA 15124 TP PLA 15124 TPR PLA 15124 TPKT
Basic composition
c Open top with canopy.
c Base completely closed.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to mechanical impacts IK08 (5J) conforming to IEC and EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with “anti-lever” hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.
03_070_083_EN.indd 7503_070_083_EN.indd 75 5/3/08 11:20:575/3/08 11:20:57
3/76
Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120º, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to 750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow direct fixing of mounting plates and/or the desired installation system, accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 to +150 ºC.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.
PLAZ. . .Polyester enclosures with closed top and open plinth-type baseIP54 (EN 60529)
PLAZ 1253
Hot-press moulded fibreglass-reinforced polyester enclosures, in grey RAL-7032 (able to withstand weather conditions).
03_070_083_EN.indd 7603_070_083_EN.indd 76 5/3/08 11:20:575/3/08 11:20:57
3/77
PLAZ. . .Polyester enclosures with closed top and open plinth-type baseIP54 (EN 60529)
Basic composition
c Closed top.
c Open plinth-type base.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to mechanical impacts IK08 (5J) conforming to IEC and EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with “anti-lever” hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.
SELECTION TABLE FOR POLYESTER ENCLOSURES WITH CLOSED TOP AND OPEN PLINTH-TYPE BASE
Height Width Depth No. of doors
Nominal dimensions (mm)
500 500 320 1 PLAZ 553 PLAZ 553 R PLAZ 553 KT PLAZ 553 P PLAZ 553 PR PLAZ 553 PKT
420 1 PLAZ 554 PLAZ 554 R PLAZ 554 KT PLAZ 554 P PLAZ 554 PR PLAZ 554 PKT
750 320 1 PLAZ 573 PLAZ 573 R PLAZ 573 KT PLAZ 573 P PLAZ 573 PR PLAZ 573 PKT
420 1 PLAZ 574 PLAZ 574 R PLAZ 574 KT PLAZ 574 P PLAZ 574 PR PLAZ 574 PKT
1000 320 2 PLAZ 5103 PLAZ 5103 R PLAZ 5103 KT PLAZ 5103 P PLAZ 5103 PR PLAZ 5103 PKT
420 2 PLAZ 5104 PLAZ 5104 R PLAZ 5104 KT PLAZ 5104 P PLAZ 5104 PR PLAZ 5104 PKT
1250 320 2 PLAZ 5123 PLAZ 5123 R PLAZ 5123 KT PLAZ 5123 P PLAZ 5123 PR PLAZ 5123 PKT
420 2 PLAZ 5124 PLAZ 5124 R PLAZ 5124 KT PLAZ 5124 P PLAZ 5124 PR PLAZ 5124 PKT
750 500 320 1 PLAZ 753 PLAZ 753 R PLAZ 753 KT PLAZ 753 P PLAZ 753 PR PLAZ 753 PKT
420 1 PLAZ 754 PLAZ 754 R PLAZ 754 KT PLAZ 754 P PLAZ 754 PR PLAZ 754 PKT
750 320 1 PLAZ 773 PLAZ 773 R PLAZ 773 KT PLAZ 773 P PLAZ 773 PR PLAZ 773 PKT
420 1 PLAZ 774 PLAZ 774 R PLAZ 774 KT PLAZ 774 P PLAZ 774 PR PLAZ 774 PKT
1000 320 2 PLAZ 7103 PLAZ 7103 R PLAZ 7103 KT PLAZ 7103 P PLAZ 7103 PR PLAZ 7103 PKT
420 2 PLAZ 7104 PLAZ 7104 R PLAZ 7104 KT PLAZ 7104 P PLAZ 7104 PR PLAZ 7104 PKT
1250 320 2 PLAZ 7123 PLAZ 7123 R PLAZ 7123 KT PLAZ 7123 P PLAZ 7123 PR PLAZ 7123 PKT
420 2 PLAZ 7124 PLAZ 7124 R PLAZ 7124 KT PLAZ 7124 P PLAZ 7124 PR PLAZ 7124 PKT
1000 500 320 1 PLAZ 1053 PLAZ 1053 R PLAZ 1053 KT PLAZ 1053 P PLAZ 1053 PR PLAZ 1053 PKT
420 1 PLAZ 1054 PLAZ 1054 R PLAZ 1054 KT PLAZ 1054 P PLAZ 1054 PR PLAZ 1054 PKT
750 320 1 PLAZ 1073 PLAZ 1073 R PLAZ 1073 KT PLAZ 1073 P PLAZ 1073 PR PLAZ 1073 PKT
420 1 PLAZ 1074 PLAZ 1074 R PLAZ 1074 KT PLAZ 1074 P PLAZ 1074 PR PLAZ 1074 PKT
1000 320 2 PLAZ 10103 PLAZ 10103 R PLAZ 10103 KT PLAZ 10103 P PLAZ 10103 PR PLAZ 10103 PKT
420 2 PLAZ 10104 PLAZ 10104 R PLAZ 10104 KT PLAZ 10104 P PLAZ 10104 PR PLAZ 10104 PKT
1250 320 2 PLAZ 10123 PLAZ 10123 R PLAZ 10123 KT PLAZ 10123 P PLAZ 10123 PR PLAZ 10123 PKT
420 2 PLAZ 10124 PLAZ 10124 R PLAZ 10124 KT PLAZ 10124 P PLAZ 10124 PR PLAZ 10124 PKT
1250 500 320 1 PLAZ 1253 PLAZ 1253 R PLAZ 1253 KT PLAZ 1253 P PLAZ 1253 PR PLAZ 1253 PKT
420 1 PLAZ 1254 PLAZ 1254 R PLAZ 1254 KT PLAZ 1254 P PLAZ 1254 PR PLAZ 1254 PKT
750 320 1 PLAZ 1273 PLAZ 1273 R PLAZ 1273 KT PLAZ 1273 P PLAZ 1273 PR PLAZ 1273 PKT
420 1 PLAZ 1274 PLAZ 1274 R PLAZ 1274 KT PLAZ 1274 P PLAZ 1274 PR PLAZ 1274 PKT
1000 320 2 PLAZ 12103 PLAZ 12103 R PLAZ 12103 KT PLAZ 12103 P PLAZ 12103 PR PLAZ 12103 PKT
420 2 PLAZ 12104 PLAZ 12104 R PLAZ 12104 KT PLAZ 12104 P PLAZ 12104 PR PLAZ 12104 PKT
1250 320 2 PLAZ 12123 PLAZ 12123 R PLAZ 12123 KT PLAZ 12123 P PLAZ 12123 PR PLAZ 12123 PKT
420 2 PLAZ 12124 PLAZ 12124 R PLAZ 12124 KT PLAZ 12124 P PLAZ 12124 PR PLAZ 12124 PKT
1500 500 320 1 PLAZ 1553 PLAZ 1553 R PLAZ 1553 KT PLAZ 1553 P PLAZ 1553 PR PLAZ 1553 PKT
420 1 PLAZ 1554 PLAZ 1554 R PLAZ 1554 KT PLAZ 1554 P PLAZ 1554 PR PLAZ 1554 PKT
750 320 1 PLAZ 1573 PLAZ 1573 R PLAZ 1573 KT PLAZ 1573 P PLAZ 1573 PR PLAZ 1573 PKT
420 1 PLAZ 1574 PLAZ 1574 R PLAZ 1574 KT PLAZ 1574 P PLAZ 1574 PR PLAZ 1574 PKT
1000 320 2 PLAZ 15103 PLAZ 15103 R PLAZ 15103 KT PLAZ 15103 P PLAZ 15103 PR PLAZ 15103 PKT
420 2 PLAZ 15104 PLAZ 15104 R PLAZ 15104 KT PLAZ 15104 P PLAZ 15104 PR PLAZ 15104 PKT
1250 320 2 PLAZ 15123 PLAZ 15123 R PLAZ 15123 KT PLAZ 15123 P PLAZ 15123 PR PLAZ 15123 PKT
420 2 PLAZ 15124 PLAZ 15124 R PLAZ 15124 KT PLAZ 15124 P PLAZ 15124 PR PLAZ 15124 PKT
03_070_083_EN.indd 7703_070_083_EN.indd 77 5/3/08 11:20:585/3/08 11:20:58
3/78
Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 180º, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to 750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow direct fixing of mounting plates and/or the desired installation system, accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 to +150 ºC.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.
PLAZ. . .TPolyester enclosures with self-ventilated top with canopy and open plinth-type baseIP54 (EN 60529)
PLAZ 7103T
Hot-press moulded, fibreglass-reinforced, self-ventilated polyester enclosures, in grey RAL-7032 (able to withstand weather conditions).
03_070_083_EN.indd 7803_070_083_EN.indd 78 5/3/08 11:20:595/3/08 11:20:59
3/79
Basic composition
c Open top with canopies.
c Open plinth-type base.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to mechanical impacts IK08 (5J) conforming to EN 50102.
c ..R model: ribbed door to make fixing of posters difficult and with “anti-lever” hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.
PLAZ. . .TPolyester enclosures with self-ventilated top with canopy and open plinth-type baseIP54 (EN 60529)
SELECTION TABLE FOR POLYESTER ENCLOSURES WITH SELF-VENTILATED TOP WITH CANOPY AND OPEN PLINTH-TYPE BASE
Height Width Depth No. of doors
Nominal dimensions (mm)
500 500 320 1 PLAZ 553 T PLAZ 553 TR PLAZ 553 TKT PLAZ 553 TP PLAZ 553 TPR PLAZ 553 TPKT
420 1 PLAZ 554 T PLAZ 554 TR PLAZ 554 TKT PLAZ 554 TP PLAZ 554 TPR PLAZ 554 TPKT
750 320 1 PLAZ 573 T PLAZ 573 TR PLAZ 573 TKT PLAZ 573 TP PLAZ 573 TPR PLAZ 573 TPKT
420 1 PLAZ 574 T PLAZ 574 TR PLAZ 574 TKT PLAZ 574 TP PLAZ 574 TPR PLAZ 574 TPKT
1000 320 2 PLAZ 5103 T PLAZ 5103 TR PLAZ 5103 TKT PLAZ 5103 TP PLAZ 5103 TPR PLAZ 5103 TPKT
420 2 PLAZ 5104 T PLAZ 5104 TR PLAZ 5104 TKT PLAZ 5104 TP PLAZ 5104 TPR PLAZ 5104 TPKT
1250 320 2 PLAZ 5123 T PLAZ 5123 TR PLAZ 5123 TKT PLAZ 5123 TP PLAZ 5123 TPR PLAZ 5123 TPKT
420 2 PLAZ 5124 T PLAZ 5124 TR PLAZ 5124 TKT PLAZ 5124 TP PLAZ 5124 TPR PLAZ 5124 TPKT
750 500 320 1 PLAZ 753 T PLAZ 753 TR PLAZ 753 TKT PLAZ 753 TP PLAZ 753 TPR PLAZ 753 TPKT
420 1 PLAZ 754 T PLAZ 754 TR PLAZ 754 TKT PLAZ 754 TP PLAZ 754 TPR PLAZ 754 TPKT
750 320 1 PLAZ 773 T PLAZ 773 TR PLAZ 773 TKT PLAZ 773 TP PLAZ 773 TPR PLAZ 773 TPKT
420 1 PLAZ 774 T PLAZ 774 TR PLAZ 774 TKT PLAZ 774 TP PLAZ 774 TPR PLAZ 774 TPKT
1000 320 2 PLAZ 7103 T PLAZ 7103 TR PLAZ 7103 TKT PLAZ 7103 TP PLAZ 7103 TPR PLAZ 7103 TPKT
420 2 PLAZ 7104 T PLAZ 7104 TR PLAZ 7104 TKT PLAZ 7104 TP PLAZ 7104 TPR PLAZ 7104 TPKT
1250 320 2 PLAZ 7123 T PLAZ 7123 TR PLAZ 7123 TKT PLAZ 7123 TP PLAZ 7123 TPR PLAZ 7123 TPKT
420 2 PLAZ 7124 T PLAZ 7124 TR PLAZ 7124 TKT PLAZ 7124 TP PLAZ 7124 TPR PLAZ 7124 TPKT
1000 500 320 1 PLAZ 1053 T PLAZ 1053 TR PLAZ 1053 TKT PLAZ 1053 TP PLAZ 1053 TPR PLAZ 1053 TPKT
420 1 PLAZ 1054 T PLAZ 1054 TR PLAZ 1054 TKT PLAZ 1054 TP PLAZ 1054 TPR PLAZ 1054 TPKT
750 320 1 PLAZ 1073 T PLAZ 1073 TR PLAZ 1073 TKT PLAZ 1073 TP PLAZ 1073 TPR PLAZ 1073 TPKT
420 1 PLAZ 1074 T PLAZ 1074 TR PLAZ 1074 TKT PLAZ 1074 TP PLAZ 1074 TPR PLAZ 1074 TPKT
1000 320 2 PLAZ 10103 T PLAZ 10103 TR PLAZ 10103 TKT PLAZ 10103 TP PLAZ 10103 TPR PLAZ 10103 TPKT
420 2 PLAZ 10104 T PLAZ 10104 TR PLAZ 10104 TKT PLAZ 10104 TP PLAZ 10104 TPR PLAZ 10104 TPKT
1250 320 2 PLAZ 10123 T PLAZ 10123 TR PLAZ 10123 TKT PLAZ 10123 TP PLAZ 10123 TPR PLAZ 10123 TPKT
420 2 PLAZ 10124 T PLAZ 10124 TR PLAZ 10124 TKT PLAZ 10124 TP PLAZ 10124 TPR PLAZ 10124 TPKT
1250 500 320 1 PLAZ 1253 T PLAZ 1253 TR PLAZ 1253 TKT PLAZ 1253 TP PLAZ 1253 TPR PLAZ 1253 TPKT
420 1 PLAZ 1254 T PLAZ 1254 TR PLAZ 1254 TKT PLAZ 1254 TP PLAZ 1254 TPR PLAZ 1254 TPKT
750 320 1 PLAZ 1273 T PLAZ 1273 TR PLAZ 1273 TKT PLAZ 1273 TP PLAZ 1273 TPR PLAZ 1273 TPKT
420 1 PLAZ 1274 T PLAZ 1274 TR PLAZ 1274 TKT PLAZ 1274 TP PLAZ 1274 TPR PLAZ 1274 TPKT
1000 320 2 PLAZ 12103 T PLAZ 12103 TR PLAZ 12103 TKT PLAZ 12103 TP PLAZ 12103 TPR PLAZ 12103 TPKT
420 2 PLAZ 12104 T PLAZ 12104 TR PLAZ 12104 TKT PLAZ 12104 TP PLAZ 12104 TPR PLAZ 12104 TPKT
1250 320 2 PLAZ 12123 T PLAZ 12123 TR PLAZ 12123 TKT PLAZ 12123 TP PLAZ 12123 TPR PLAZ 12123 TPKT
420 2 PLAZ 12124 T PLAZ 12124 TR PLAZ 12124 TKT PLAZ 12124 TP PLAZ 12124 TPR PLAZ 12124 TPKT
1500 500 320 1 PLAZ 1553 T PLAZ 1553 TR PLAZ 1553 TKT PLAZ 1553 TP PLAZ 1553 TPR PLAZ 1553 TPKT
420 1 PLAZ 1554 T PLAZ 1554 TR PLAZ 1554 TKT PLAZ 1554 TP PLAZ 1554 TPR PLAZ 1554 TPKT
750 320 1 PLAZ 1573 T PLAZ 1573 TR PLAZ 1573 TKT PLAZ 1573 TP PLAZ 1573 TPR PLAZ 1573 TPKT
420 1 PLAZ 1574 T PLAZ 1574 TR PLAZ 1574 TKT PLAZ 1574 TP PLAZ 1574 TPR PLAZ 1574 TPKT
1000 320 2 PLAZ 15103 T PLAZ 15103 TR PLAZ 15103 TKT PLAZ 15103 TP PLAZ 15103 TPR PLAZ 15103 TPKT
420 2 PLAZ 15104 T PLAZ 15104 TR PLAZ 15104 TKT PLAZ 15104 TP PLAZ 15104 TPR PLAZ 15104 TPKT
1250 320 2 PLAZ 15123 T PLAZ 15123 TR PLAZ 15123 TKT PLAZ 15123 TP PLAZ 15123 TPR PLAZ 15123 TPKT
420 2 PLAZ 15124 T PLAZ 15124 TR PLAZ 15124 TKT PLAZ 15124 TP PLAZ 15124 TPR PLAZ 15124 TPKT
03_070_083_EN.indd 7903_070_083_EN.indd 79 5/3/08 11:21:005/3/08 11:21:00
A-1
50
A-1
50
B-150B-150
37.5 75
C-8
25
28.5
C
A260
28.521
25
A-2
55
C-140
C-42
B-95
A-9
5
A-9
5
B-95
1
4
2
1 1
4
2
1
1
C-170
A-2
00
25
A-1
50
B-150
B-120
C-1
25
37.5
C-1
40
B-205
M8
C-13
25
28.5
C
A260
28.521
25
A-2
55
C-140
C-42
B = 500 / 750
17 / 28*
B-95
A-9
5
A-2
53
285/535
A-1
50
B-150
B-120
C-1
25
75
C-1
40
B-205
M840
B =1000/1250
500/750
405 405/655
500
37
A-9
5
B-95A-2
53
285 285/535
1
4
2
3
1
3
1
1
1
4
2
1
3
311
1 1
4 4
1
25
C-170
A-2
00
3/80
FIG. 1
PLA...
FIG. 2
PLA...KT
PLA. . . Polyester enclosures completely closedIP65 (EN 60529)
Dimensions (mm)
03_070_083_EN.indd 8003_070_083_EN.indd 80 5/3/08 11:21:015/3/08 11:21:01
A-1
50
A-1
50
B-150B-150
B-120
C-1
25
B-120C
-125
37.5
B = 500 / 750
C-1
40
B-205
M8
75
C-8
25
28.5
C
A+
38
C-1
40
B-205
M8
B =1000/1250
500 500/750
405 405/655
260
28.5
21
25
A-2
55
C-140
C-42
40
23 / 28* 37
38
B-95
A-9
5
A-9
5
B-954
2
1
4
2
1
1
1
3
4
2
4
3
1
3
3
1
1 1
C-170
A-2
00
25
3/81
FIG. 1
PLA...T
1 Bosses on the back of enclosures starting with 1000 mm wide allow the fixing of partial mounting plates (see plates section). Bosses at the top and bottom are used for fixing depth adjustable supports, internal doors, 19” racks, etc.
In general, all bosses- including those on the sides and on the interior of the door- are prepared for M8 inserts Ref.: TEX 8 for fixing various material.
2 Bosses with M8 inserts equipped with studs for fixing the mounting plates.
3 Centres for floor or plinth fixing.
4 Dimensions of the door opening.
NOTE: in 1250 mm width enclosures, the left door is 500 mm and the right is 750 mm.
PLA. . .TPolyester enclosures with closed top and open plinth-type baseIP54 (EN 60529)
* For mounting plates with reinforcement wing.
Dimensions (mm)
03_070_083_EN.indd 8103_070_083_EN.indd 81 5/3/08 11:21:015/3/08 11:21:01
B-150
A-1
50
A-1
50
37.5
A-1
50
B-150
75
C-42
C-8 260
25
A-2
55
C-140
A+
55
28.5
C
28.521
55
B-95
A-9
5
A-9
5
B-95
1
4
2
1
1
4
2
1
1
33
C-170
A-2
00
25
A-1
50A
-150
B-150
A-9
5
B-95
75
1
4
2
1
B-60
C-1
60
B =1000/1250
500 500/750
405 405/655
C-6
8
B-81
M840
37
6.5 6.5
3
44
3
25
C-42
C-8 260
25
A-2
55
C-140
A+
55
28.5
C
28.521
55
1
C-170
A-2
00
B-150
A-1
50
B-95
A-9
5
37.5
1
4
2
1
B-60
C-1
60
23 / 28*
M8
B = 500/750
C-6
8
B-81
6.5 6.5
3
3
3/82
FIG. 1
PLAZ...
FIG. 2
PLAZ...R
PLAZ. . .Polyester enclosures with self-ventilated top with canopy and closed baseIP54 (EN 60529)
Dimensions (mm)
03_070_083_EN.indd 8203_070_083_EN.indd 82 5/3/08 11:21:015/3/08 11:21:01
B-95
A-9
5
A-9
5
B-95
B-150
A-1
50
37.5
B-60
C-1
60
23 / 28*
M8
B = 500/750
C-6
8
B-81
6.5 6.5
B-60
C-1
60
B =1000/1250
500 500/750
405 405/655
C-6
8
B-81
M840
37
6.5 6.5
A-1
50A
-150
B-150
75
C-42
C-8 260
25
A-2
55
C-140
A+
93
28.5
C
28.521
3855
1
4
2
1
1
4
2
1
1
3
44
3
3
3
C-170
A-2
00
25
3/83
FIG. 1
PLAZ...T
1 Bosses on the back of enclosures starting with 1000 mm wide allow the fixing of partial mounting plates (see plates section). Bosses at the top and bottom are used for fixing depth adjustable supports, internal doors, 19“ racks, etc.
In general, all bosses- including those on the sides and on the interior of the door- are prepared for M8 inserts Ref.: TEX 8 for fixing various material.
2 Bosses with M8 inserts equipped with studs for fixing the mounting plates.
3 Centres for floor or plinth fixing.
4 Dimensions of the door opening.
* For mounting plates with reinforcement wing.
NOTE: in 1250 mm width enclosures, the left door is 500 mm and the right is 750 mm.
PLAZ. . .TPolyester enclosures with self-ventilated top with canopy and open plinth-type baseIP54 (EN 60529)
Dimensions (mm)
03_070_083_EN.indd 8303_070_083_EN.indd 83 5/3/08 11:21:025/3/08 11:21:02
3/84
PLA Composition accessories
PVC frame with sealing gasket that permits lateral coupling of enclosures PLA or PLA...T.
They complement the MUPLA coupling frame for lateral union of enclosures.2 versions: SUPLA for enclosures without canopy and SUPLAT for enclosures with canopy.
Horizontal coupling frame for PLA and PLA...T enclosures
Height (A)
Enclosure dimensions
Depth (C)
Reference
500 320 MUPLA 53
750 320 MUPLA 73
1000 320 MUPLA 103
1250 320 MUPLA 123
1500 320 MUPLA 153
500 420 MUPLA 54
750 420 MUPLA 74
1000 420 MUPLA 104
1250 420 MUPLA 124
1500 420 MUPLA 154
Supplements for coupling PLA and PLA...T enclosures
Depth (C)
Enclosure dimensionsPLA
320 SUPLA 3 SUPLA 3T
420 SUPLA 4 SUPLA 4T
PLA...T
MUPLA...SUPLA...
MUPLA...SUPLA...
03_084_100_EN.indd 8403_084_100_EN.indd 84 2/4/08 12:55:052/4/08 12:55:05
A +
38
C = 320/420
3/85
PLA Composition accessories
Coupling enclosures using an adhesive gasket that guarantees watertightness at the vertical joint of the enclosures PLA.
Ref.: UVPLA.
Application Reference
Adhesive gasket UVPLA
Vertical coupling of enclosures
Made of reinforced pressed polyester, for exterior installation of closed enclosures.
c Colour RAL-7032.
c Self-extinguishable; high resistance to impacts and temperature.
c Excellent resistance to outdoor conditions.
c The nominal height of the enclosure is increased 38 mm.
Canopies
Width (B) Depth (C) No. of doors
ReferenceFor attachment to enclosures
500 320 1 TJPLA 53
750 320 1 TJPLA 73
1000 320 2 TJPLA 103
1250 320 2 TJPLA 123
500 420 1 TJPLA 54
750 420 1 TJPLA 74
1000 420 2 TJPLA 104
1250 420 2 TJPLA 124
03_084_100_EN.indd 8503_084_100_EN.indd 85 2/4/08 12:55:062/4/08 12:55:06
3/86
PLA Composition accessories
B+35
200
B
C
305
C-10
395
To be coupled to enclosures with open bases, Ref.: PLAZ…
Made of fiberglass reinforced polyester.
c Colour RAL-7032.
c Self-extinguishable; high resistance to impacts and temperature.
c Double insulation; excellent resistance to weather conditions.
c 200 mm front cover accessible from the interior.
c 305 mm height fixed front panel, allowing the enclosure to be completely or partially flush built in.
c Fixing profile for cable entry.
c Sides with knock-out entry PG-36.
Plinths
Width (B) Depth (C) No. of doors
ReferenceFor attachment to enclosures
500 320 1 ZHPLA 53
750 320 1 ZHPLA 73
1000 320 2 ZHPLA 103
1250 320 2 ZHPLA 123
500 420 1 ZHPLA 54
750 420 1 ZHPLA 74
1000 420 2 ZHPLA 104
1250 420 2 ZHPLA 124
aaaaaaaaB+20
B
C
300/420
60
65To be coupled to enclosures with closed bases, Ref.: PLA…
Made of fiberglass reinforced polyester.
c Colour RAL-7032.
c Self-extinguishable; high resistance to impacts and temperature.
c Excellent resistance to outdoor conditions.
Bases
Width (B) Depth (C) No. of doors
ReferenceFor attachment to enclosures
500 320 1 ZNPLA 53
750 320 1 ZNPLA 73
1000 320 2 ZNPLA 103
1250 320 2 ZNPLA 123
500 420 1 ZNPLA 54
750 420 1 ZNPLA 74
1000 420 2 ZNPLA 104
1250 420 2 ZNPLA 124
03_084_100_EN.indd 8603_084_100_EN.indd 86 2/4/08 12:55:062/4/08 12:55:06
26
(1)
B+52A-3
7518
7,5
3/87
PLA Composition accessories
To be coupled to the models of enclosures with open plinth-type bases, Ref.: PLAZ…
Made of fiberglass reinforced polyester.
c Colour RAL-7032.
c Self-extinguishing; excellent resistance to outdoor conditions.
c Easily machined.
1-door enclosures 2-door enclosures
Cable entry plate
Width (B) Depth (C) No. of doors
ReferenceFor attachment to enclosures
500 320 1 ECPLAZ 53
750 320 1 ECPLAZ 73
1000 320 2 ECPLAZ 103
1250 320 2 ECPLAZ 123
500 420 1 ECPLAZ 54
750 420 1 ECPLAZ 74
1000 420 2 ECPLAZ 104
1250 420 2 ECPLAZ 124
100
C-7
8
C-2
04
25
63
1011
430
21 10 31
B-40
B-40
C-7
8
C-2
04
25
11
63
10
Set of 6 metal pieces in passivated zinc-coated steel.
c Fixing to the sides with 4 or 6 pieces in horizontal (1).
c In all cases, the maximum admissible load is that which corresponds to 150 kg/m2 of plate surface. See the enclosure lifting table, page 3/111.
Ref.: FMPLA.
Wall mounting kit
03_084_100_EN.indd 8703_084_100_EN.indd 87 2/4/08 12:55:082/4/08 12:55:08
C-160
B-60
3/88
PLA Composition accessories
Frame for fixing those enclosures with open plinth-type bases directly to the floor, Ref.: PLAZ…
Fixing enclosures with open bases to the floor, Ref.: PLA… is done directly, with the solution being a stud with a standard screw via the ZNPLA bottom.
Width (B) Depth (C) No. of doors
ReferenceFor attachment to enclosures
Ref.: FS/PLA2.
Floor-fixing frame
500 320 1 MFPLAZ 53
750 320 1 MFPLAZ 73
1000 320 2 MFPLAZ 103
1250 320 2 MFPLAZ 123
500 420 1 MFPLAZ 54
750 420 1 MFPLAZ 74
1000 420 2 MFPLAZ 104
1250 420 2 MFPLAZ 124
Set of 4 studs for floor fixing
Door retainers to be directly incorporated into the indicated enclosures.
c Opening of the retainer: 90º or 120º for all models. Ref. RET/PLAU.
c Opening of the retainer: 110º for models PLA, PLA...T and PLAZ.Ref. RET/PLA.
RET/PLAU
RET/PLA
Door retainer
03_084_100_EN.indd 8803_084_100_EN.indd 88 2/4/08 12:55:092/4/08 12:55:09
25
C
30*
C-40
E
D
3/89
PLA Composition accessories
Internal door manufactured in painted aluminium, grey RAL-7032.
Double bar locks, allowing change for triangle, square, etc. inserts of CRN enclosures (see general catalogue).
In enclosures with a closed bottom, Ref.: PLA, the internal PIPLA doors are coupled directly.
In models with open plinth-type base, Ref.: PLAZ..., the PTZ adapter plates must be ordered separately (see footnote).
Depth of the positioning of the internal door is adjustable 25 mm.* In enclosures with a transparent KT door, subtract 5 mm.
Internal doors
No. of doors Individual internal doors in 2-door enclosure reference*Width (B)Height (A)
Total lower door reference*D E
Weight (kg)
For attachment to enclosures Dimensions
* To be coupled to enclosures with open bottom, Ref.: PLAZ, adaptor plates must be ordered separately, Ref.: PTZ 320 or PTZ 420, for 320 or 420 mm depth one-door enclosures.
PTZ 320/2P or PTZ 420/2P must be ordered for two-door enclosures.
500 500 1 PIPLA 55 - 398 398 1.6
500 750 1 PIPLA 57 - 398 648 2.2
500 1000 2 - PIPLA 55 + PIPLA 55 - - -
500 1250 2 - PIPLA 55 + PIPLA 57 - - -
750 500 1 PIPLA 75 - 648 398 2.2
750 750 1 PIPLA 77 - 648 648 3.1
750 1000 2 - PIPLA 75 + PIPLA 75 - - -
750 1250 2 - PIPLA 75 + PIPLA 77 - - -
1000 500 1 PIPLA 105 - 898 398 2.8
1000 750 1 PIPLA 107 - 898 648 4.1
1000 1000 2 - PIPLA 105 + PIPLA 105 - - -
1000 1250 2 - PIPLA 105 + PIPLA 107 - - -
1250 500 1 PIPLA 125 - 1148 398 3.4
1250 750 1 PIPLA 127 - 1148 648 5
1250 1000 2 - PIPLA 125 + PIPLA 125 - - -
1250 1250 2 - PIPLA 125 + PIPLA 127 - - -
1500 500 1 PIPLA 155 - 1398 398 4
1500 750 1 PIPLA 157 - 1398 648 6
1500 1000 2 - PIPLA 155 + PIPLA 155 - - -
1500 1250 2 - PIPLA 155 + PIPLA 157 - - -
03_084_100_EN.indd 8903_084_100_EN.indd 89 2/4/08 12:55:102/4/08 12:55:10
3/90
PLA Composition accessories
Direct-action 5 mm double bar lock, operated with key LDB5. Included in standard supply.Accepts all the types of operation referenced in the following table by changing the inserts of the standard lock.
Embellishing kit for direct-action key-operated lock (without handle): Ref.: EB/PLA.
Standard lock for completely closed enclosures
CHANGING INSERTS OF THE STANDARD LOCK
Specifications ReferenceType of lock Type of operation
6.5 mm triangle
lock, operated TT6/CRN
with key LT6,5.
7 mm triangle
ock, operated TT7/CRN
with key LT8.
8 mm triangle
lock, operated TT8/CRN
with key LT8.
6 mm square
lock, operated TC6/CRN
with key LC7.
7 mm square
lock, operated TC7/CRN
with key LC7.
8 mm square
lock, operated TC8/CRN
with key LC8.
Double bar
lock, operated
with key LDB5. TDB/PLA
Included in
standard supply.
Padlock BC/PLA
* To obtain the complete lock, in addition to the EBM/PLA trim, the T…/OLN or T…/PLA types of locks, indi-cated on the following page, must be ordered separately.
CHANGING TO HANDLE LOCK
Specifications ReferenceType of operation
Embellishing kit
with handle lock.* EBM/PLA*
03_084_100_EN.indd 9003_084_100_EN.indd 90 2/4/08 12:55:112/4/08 12:55:11
3/91
PLA Composition accessories
Double bar handle lock, operated by key LDB5. Included in standard supply.Accepts all the types of operation referenced in the following table by changing the inserts.
Embellishing kit with handle Ref.: EBM/PLA.
* To obtain the complete lock, in addition to the CBCM/PLA trim, the T…/OLN type of lock, indicated on this page, must be ordered separately.** To obtain the complete lock, in addition to the EB/PLA trim, the T…/CRN or TDB/PLA types of locks, indi-cated on the previous page, must be ordered separately.
Standard lock for enclosures with open top or open base
CHANGING INSERTS OF THE STANDARD LOCK
7 mm triangle
lock, operated TT7/OLN
with key LT8.
8 mm triangle
lock, operated TT8/OLN
with key LT8.
6 mm square
lock, operated TC6/OLN
with key LC7.
7 mm square
lock, operated TC7/OLN
with key LC7.
8 mm square
lock, operated TC8/OLN
with key LC8.
Lock with key type 405. TL/OLN
Lock with key type JIS. TJIS/OLN
Lock with reinforced-type key TLR/OLN
Lock with key type FAC. TFAC/OLN
DIN insert
adapter. ABDIN/OLN
Pushbutton operated. TS/PLA
5 mm double
bar lock included TDBM/PLA
in standard supply.
Handle lock with CBCM/PLA*
padlocking device.*
Protective cover (optional). TPBM/PLA
CHANGING TO LOCK WITHOUT HANDLE
Specifications ReferenceType of lock Type of operation
Specifications ReferenceType of lock Type of operation
Embellishing kit without
handle lock.** EB/PLA**
03_084_100_EN.indd 9103_084_100_EN.indd 91 2/4/08 12:55:122/4/08 12:55:12
A - 158
A - 200
1
1
C -
116
C -
170
27
21 21
3/92
PLA Composition accessories
Support set made of the fixing supports and all the necessary hardware, for fixing the PPTR transparent protective screens to the corresponding PLA enclosures.
Made of 4 mm transparent polycarbonate. Supplied without the SPTR 77 support set, which must be purchased separately.
Transparent protective screens
Height Width
ReferenceEnclosure dimensions
500 500 PPTR 55
500 750 PPTR 57
750 500 PPTR 75
750 750 PPTR 77
Fixing supports for protective screens
Reference Application
SPTR 77 PPTR 55/57/75/77
03_084_100_EN.indd 9203_084_100_EN.indd 92 2/4/08 12:55:132/4/08 12:55:13
G
E
D F
350
437.5
H-87.5
H
E
e10.5
150
100
75
12.5
10.5 25 25
2525
25
25
25
25
Ø6.5
Ø8.5
Ø6.5
Ø8.5
150
100
75
10.5
2525
10.5
25 25
Ø 6.5
Ø 8.5
Ø 6.5Ø 8.5
3/93
PLA Mounting accessories
Made of galvanised steel sheet, with reinforcement fold on models starting with a height of 1000 mm.
Directly joined to the bottom of the enclosure itself or to the depth adjustable supports.
On two-door enclosures, a full plate or 2 partial plates may be fitted. See table.
Enclosures starting with a height of 1000 mm are equipped with intermediate fixing bosses so the PMM plates of a height less than the nominal height of the enclosure can be positioned (see note (1) below). In this case, inserts Ref.: TEX 8 must be ordered separately.
c Maximum load 150 kg/m2.
models from PMM 1010
FIG. 1 FIG. 2
Metal mounting plates
500 500 1 PMM 55 1 - - 390 375 350 350 - 2 2.5
500 750 1 PMM 75 1 - - 640 375 600 350 - 2 3.8
500 1000 2 PMM 510 2 PMM 55 + PMM 55 1 390 875 350 -0 437.5 2.5 6.3
500 1250 2 - - PMM 55 + PMM 75 1 -0 -0 -0 -0 - - -
750 500 1 PMM 75 1 - - 640 375 600 350 - 2 3.8
750 750 1 PMM 77 1 - - 640 625 600 600 - 2.5 7.8
750 1000 2 PMM 710 2 PMM 75 + PMM 75 1 640 875 600 -0 437.5 2.5 10.6
750 1250 2 PMM 712 2 PMM 75 + PMM 77 1 640 1125 600 -0 687.5 2.5 17.6
1000 500 1 PMM 105 1 - - 890 375 850 350 - 2.5 6.5
1000 750 1 PMM 107 1 - - 890 625 850 600 - 2.5 10.8
1000 1000 2 PMM 1010 2 PMM 105 + PMM 105 1 875 875 850 -0 437.5 2.5 15
1000 1250 2 PMM 1012 2 PMM 105 + PMM 107 1 875 1125 850 -0 687.5 2.5 19.3
1250 500 1 PMM 125 1 - - 1125 375 1100 350 - 2.5 8.6
1250 750 1 PMM 127 1 - - 1125 625 1100 600 - 2.5 14.2
1250 1000 2 PMM 1210 2 PMM 125 + PMM 125 1 1125 875 1100 -0 437.5 2.5 19.4
1250 1250 2 PMM 1212 2 PMM 125 + PMM 127 1 1125 1125 1100 -0 687.5 2.5 24.9
1500 500 1 PMM 155 1 - - 1375 375 1350 350 - 2.5 10.6
1500 750 1 PMM 157 1 - - 1375 625 1350 600 - 2.5 17.3
1500 1000 2 PMM 1510 2 PMM 155 + PMM 155 1 1375 875 1350 -0 437.5 2.5 23.8
1500 1250 2 PMM 1512 2 PMM 155 + PMM 157 1 1375 1125 1350 -0 687.5 2.5 30.5
(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PMM of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure
Height (A) Width (B)
No. of doors
Fig. No.Reference Fig. No. D E F G H e (kg)
To couple to enclosures with dimensions (1) Full plate Individual plates, two-door
enclosuresDimensions full plate
Reference
03_084_100_EN.indd 9303_084_100_EN.indd 93 2/4/08 12:55:152/4/08 12:55:15
G
E
D F
350
437.5
H-87.5
H
E
e10.510.5
150
100
75
150
100
75
10.5
10.5
3/94
PLA Mounting accessories
Made of bakelite in black RAL-9005 (Ref.: PMB..) or in polyester in grey RAL-7032 (Ref.: PMA..).
Directly joined to the bottom of the enclosure itself or to the depth adjustable supports.
On two-door enclosures, a full plate or 2 partial plates may be fitted. See table.
Enclosures starting with a height of 1000 mm are equipped with intermediate fixing bosses so the PMB plates of a height less than the nominal height of the enclosure can be positioned (see note (1) below). In this case, inserts Ref.: TEX 8 must be ordered separately.
c Maximum load 150 kg/m2.
FIG. 1 FIG. 2
Insulating mounting plates
(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PM.. of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure.
(2) PMA: polyester, PMB: bakelite.
500 500 1 PM.. 55 1 - - 390 375 350 350 - 4 0.9
500 750 1 PM.. 75 1 - - 640 375 600 350 - 4 1.3
500 1000 2 PM.. 510 2 PM.. 55 + PM.. 55 1 390 875 350 -0 437.5 5 2.4
500 1250 2 - - PM.. 55 + PM.. 75 1 -0 -0 -0 -0 - - -
750 500 1 PM.. 75 1 - - 640 375 600 350 - 4 1.3
750 750 1 PM.. 77 1 - - 640 625 600 600 - 5 2.8
750 1000 2 PM.. 710 2 PM.. 75 + PM.. 75 1 640 875 600 -0 437.5 5 3.9
750 1250 2 PM.. 712 2 PM.. 75 + PM.. 77 1 640 1125 600 -0 687.5 5 5
1000 500 1 PM.. 105 1 - - 890 375 850 350 - 5 2.3
1000 750 1 PM.. 107 1 - - 890 625 850 600 - 5 3.9
1000 1000 2 PM.. 1010 2 PM.. 105 + PM.. 105 1 890 875 850 -0 437.5 5 5.5
1000 1250 2 PM.. 1012 2 PM.. 105 + PM.. 107 1 890 1125 850 -0 687.5 5 7.1
1250 500 1 PM.. 125 1 - - 1140 375 1100 350 - 5 3
1250 750 1 PM.. 127 1 - - 1140 625 1100 600 - 5 5
1250 1000 2 PM.. 1210 2 PM.. 125 + PM.. 125 1 1140 875 1100 -0 437.5 5 7
1250 1250 2 PM.. 1212 2 PM.. 125 + PM.. 127 1 1140 1125 1100 -0 687.5 5 9
1500 500 1 PMB 155 1 - - 1390 375 1350 350 - 5 3.7
1500 750 1 PMB 157 1 - - 1390 625 1350 600 - 5 6.1
1500 1000 2 PMB 1510 2 PMB 155 + PMB 155 1 1390 875 1350 -0 437.5 5 8.6
1500 1250 2 PMB 1512 2 PMB 155 + PMB 157 1 1390 1125 1350 -0 687.5 5 11
Height (A) Width (B)
No. of doors
Fig. No.Reference (2) Fig. No. D E F G H e (kg)
To couple to enclosures with dimensions (1) Full plate Individual plates, two-door
enclosuresDimensions full plate
Reference (2)
Bakelite Polyester
03_084_100_EN.indd 9403_084_100_EN.indd 94 2/4/08 12:55:192/4/08 12:55:19
3/95
PLA Mounting accessories
Plates specially designed for quick mounting of equipment using the TFP locking nuts. Made of zinc-coated steel.
Directly joined to the bottom of the enclosure itself or to the depth adjustable supports.
Possibility of incorporating 2 individual plates on two-door enclosures. See table.
Enclosures starting with a height of 1000 mm are equipped with intermediate fixing bosses so the PMR plates of a height less than the nominal height of the enclosure can be positioned (see note (1) below). In this case, inserts Ref.: TEX 8 must be ordered separately.
c Maximum load 150 kg/m2.
Universal perforated mounting plates
(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PMM of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure.
Height (A) Width (B)
No. of doors
Reference Reference D E F GThickness
(mm))Weight (kg)
To join the enclosures (1) Full plate Individual plates, two-door enclosures
Dimensions full plate
500 500 1 PMR 55 - 370 376 350 350 2 1.1
500 750 1 PMR 57 - 370 626 350 600 2 1.7
500 1000 2 - PMR 55 + PMR 55 370 376/376 350 350/350 2 -
500 1250 2 - PMR 55 + PMR 57 370 376/626 350 350/600 2 -
750 500 1 PMR 75 - 620 376 600 350 2 1.7
750 750 1 PMR 77 - 620 626 600 600 2 2.7
750 1000 2 - PMR 75 + PMR 75 620 376/376 350 350/350 2 -
750 1250 2 - PMR 75 + PMR 77 620 376/626 350 350/600 2 -
1000 500 1 PMR 105 - 870 376 850 350 2 2.1
1000 750 1 PMR 107 - 870 626 850 600 2 4.1
1000 1000 2 - PMR 105 + PMR 105 870 376/376 850 350/350 2 -
1000 1250 2 - PMR 105 + PMR 107 870 376/626 850 350/600 2 -
1250 500 1 PMR 125 - 1120 376 1100 350 2 3.3
1250 750 1 PMR 127 - 1120 626 1100 600 2 4.8
1250 1000 2 - PMR 125 + PMR 125 1120 376/376 1100 350/350 2 -
1250 1250 2 - PMR 125 + PMR 127 1120 376/626 1100 350/600 2 -
1500 500 1 PMR 155 - 1370 376 1350 350 2 4.2
1500 750 1 PMR 157 - 1370 626 1350 600 2 6.3
1500 1000 2 - PMR 155 + PMR 155 1370 376/626 1350 350/350 2 -
1500 1250 2 - PMR 155 + PMR 157 1370 376/626 1350 350/600 2 -
F
D
GE
15
03_084_100_EN.indd 9503_084_100_EN.indd 95 2/4/08 12:55:212/4/08 12:55:21
3/96
PLA Mounting accessories
c Allow for depth adjustment of PMM, PMB and PMR mounting plates, on any model of enclosure.
c Set of 4 adjustable supports on the profile of the aluminium guide, able to be fixed at any point along its entire length and with reference positioning every 25 mm.
c Models with a closed base. Ref.: PLA...The DPLA adjustable supports can be coupled directly without the need for other accessories.
Detail of DPLA plate supports in enclosure with closed base.
62*
C
35
C-70
62*
C
35
C-70
* For enclosures with a transparent KT door, subtract 5 mm.
enclosure with open plinth-type base, reference PLAZ… , with two doors, with adjustable plate fixed with DPLA supports and PTZ adaptor plates.
Set of 4 adjustable fixing supports for fixing an additional plate.
Ref.: EDPLA.
Detail of the DPLA plate supports with an additional set of fixing supports, Ref.: EDPLA, allowing the placement of two plates (back to back), for example in enclosures with a rear door.
PTZ 420
PTZ 420/2P
Set of adjustable mounting plate supports
c Two-door modelsTwo sets of DPLA adjustable supports must be ordered, and for the models open bottom, add one PTZ.../2P set.
* In two-door enclosures, in order to mount a full plate or two individual plates, 2 DPLA plate fixing sets must
be ordered, as indicated in the table.
To be installed in enclosures To be installed in enclosures reference
Depth (C) No. of doors PLA... PLAZ...
320 1 DPLA 320 DPLA 320 + PTZ 320
420 1 DPLA 420 DPLA 420 + PTZ 420
320 2 (2) DPLA 320* (2) DPLA 320* + PTZ 320/2P
420 2 (2) DPLA 420* (2) DPLA 420* + PTZ 420/2P
c Models with open plinth-type base. Ref.: PLAZ... In addition to the DPLA adjustable supports, a set of PTZ adaptor plates must be ordered.
DPLA 420
Set of fixing supports for additional plate
03_084_100_EN.indd 9603_084_100_EN.indd 96 2/4/08 12:55:222/4/08 12:55:22
Detail of the MOL profile fixed to the back of the enclosure.
3/97
CDP double profile DIN rail for direct fixing of equipment. Detail of the TDC sliding nut.
Detail of the MOL profile and TDM nut.The notches in the profile permit adjustment every 2.5 mm.
Set of two vertical profiles for direct fixing to the back of the enclosure.The notches in the profile every 2.5 mm and the marks every 25 mm facilitate the positioning of plates, rails, etc.
To make depth adjustment of the chassis possible, the MOL profiles must be fixed on a set of DPLA or DPLA + PTZ adjustable mounting plate supports, as in the following table.
Detail of the MOL profile fixed to the set of DPLA adjustable plate support.
PLA Mounting accessories
Universal chassis system
Set of profiles for universal chassis
Depth (C) No. of doors PLA... PLAZ...
To be installed in enclosures To be installed in enclosures reference
320 1 DPLA 320 DPLA 320 + PTZ 320
420 1 DPLA 420 DPLA 420 + PTZ 420
320 2 (2) DPLA 320 (2) DPLA 320 + PTZ 320/2P
420 2 (2) DPLA 420 (2) DPLA 420 + PTZ 420/2P
To couple to enclosures with height (A) Reference
750 MOL 75
1000 MOL 100
1250 MOL 125
1500 MOL 150
Universal chassis made up of a set of 2 MOL profiles prepared for partial mounting plates and DIN rails, for fixing any type of equipment.
The chassis can be fixed directly to the back of the enclosure or on the set of adjustable mounting plate supports, in this case making depth adjustment possible.
In two-door enclosures with 1000 and 1250 mm width, two 500 mm chassis, or 1 of 500 + 1 of 750 mm width, respectively, can be mounted.
03_084_100_EN.indd 9703_084_100_EN.indd 97 2/4/08 12:55:242/4/08 12:55:24
B - 100
A - 100
45°
40
20
44,5
7
77
44,5
40
7
10
B-95
H
3/98
Insulating polyester mounting plates, to be installed on the side of PLA enclosures.
The TEX8 inserts must be ordered separately.
Lateral mounting plates
Height Depth
ReferenceEnclosure dimensions
500 320 PMLA 53
500 420 PMLA 54
750 320 PMLA 73
750 420 PMLA 74
1000 320 PMLA 103
1000 420 PMLA 104
1250 320 PMLA 123
1250 420 PMLA 124
Made of galvanised steel. They are placed on the MOL profiles using TDM 8 nuts and TOR 16/8A screws, which must be ordered separately.
To couple to enclosures with width (B)
Plate height (H)
Reference
500 247 PMP 2550
750 247 PMP 2575
1000* 247 PMP 25100
500 397 PMP 4050
750 397 PMP 4075
1000* 397 PMP 40100
* The 1000 mm width enclosures allow for mounting 2 chassis with PMP...50 plates.
PLA Mounting accessories
Partial mounting plates for universal chassis
03_084_100_EN.indd 9803_084_100_EN.indd 98 2/4/08 12:55:312/4/08 12:55:31
3/99
PLA Mounting accessories
Rails of galvanised steel. They are placed on the MOL profiles using TDM 6 nuts and TOR 12/6A screws, which must be ordered separately.
* The 1000 mm width enclosures allow for mounting 2 chassis with C...50 rails.
Metal rails and nuts
To couple to enclosures with width (B)
Double profile reference
Symmetric DIN reference35 7.5
Symmetric DIN reference35 15
Asymmetric DIN reference
500 - CSPLA 50 CAPLA 50 -
750 - CSPLA 75 CAPLA 75 -
1000 - CSPLA 100 CAPLA 100 -
In 2 metre strips CO 35 - CA 32 CDP 200
In 2 metre strips COT 35 - CAT 32 -
In 2 metre strips - CO 35/15 - -
In 2 metre strips - COT 35/15 - -
(1) For symmetrical rails, Ref.: CO, COT and CSPLA, and double profile CDP...
(2) For double profile rails CDP...
Thread typeUnits per package Units per package Length (mm) Units per package
Nuts for fixing equipment Nuts for MOL profiles Fixing screw with washer
Units per package
M4 TDE 4 100 - 100 - - TOR 10/4A 10 100
M4 - - - - - - TOR 16/4A 16 100
M5 TDE 5 100 - - - - TOR 12/5A 12 100
M5 - - TDC 56 100 - - TOR 18/5A 18 100
M6 TDE 6 100 TDC 56 100 TDM 6 10 TOR 12/6A 12 100
M6 - - - - - - TOR 18/6A 18 100
M8 - - - - TDM 8 10 TOR 16/8A 16 50
M8 - - - - - - TOR 20/8A 20 10
Sheet ∅ 4.8 mm TOR 16/5AT 16 100
MOUNTING ACCESSORIES
(2)(1)
03_084_100_EN.indd 9903_084_100_EN.indd 99 2/4/08 12:55:332/4/08 12:55:33
12
18
C-1
00
25
B-4227
12
250
200
200
200
200
11x13
3/100
PLA Mounting accessories
BANPLA tray to be placed horizontally to support various materials, or simply as a separator. Designed to be installed in one-door enclosures.
It is mounted directly on the bottom of the enclosure using the lateral bosses.
If you want to place the tray, or various trays, at differing heights, 2 sets of 2 SPLA vertical profiles (total of 4), must be ordered, as indicated in the table.
Maximum load:Depth 320: 60 kgDepth 420: 50 kg
* Are only necessary if you want to place the tray at differing heights.
(1) For the 1250 mm enclosures, these trays may be placed using the SBPLA profiles, on the 500 and
750 mm side.
Support tray
Height (A) Width (B) Depth (C)
ReferenceTo couple to enclosures (1)
500 500 320 BANPLA 53 -
500 750 320 BANPLA 73 -
750 500 320 BANPLA 53 2 SPLA 75
750 750 320 BANPLA 73 2 SPLA 75
1000 500 320 BANPLA 53 2 SPLA 100
1000 750 320 BANPLA 73 2 SPLA 100
1250 500 320 BANPLA 53 2 SPLA 125
1250 750 320 BANPLA 73 2 SPLA 125
1500 500 320 BANPLA 53 2 SPLA 150
1500 750 320 BANPLA 73 2 SPLA 150
500 500 420 BANPLA 54 -
500 750 420 BANPLA 74 -
750 500 420 BANPLA 54 2 SPLA 75
750 750 420 BANPLA 74 2 SPLA 75
1000 500 420 BANPLA 54 2 SPLA 100
1000 750 420 BANPLA 74 2 SPLA 100
1250 500 420 BANPLA 54 2 SPLA 125
1250 750 420 BANPLA 74 2 SPLA 125
1500 500 420 BANPLA 54 2 SPLA 150
1500 750 420 BANPLA 74 2 SPLA 150
Tray Supports*
For 19” RACK accessories, consult the VDI catalogue.
Ref.: SB/PLA.
19” rack support and trays for two-door enclosures
03_084_100_EN.indd 10003_084_100_EN.indd 100 2/4/08 12:55:382/4/08 12:55:38
3/101
PLA Current distribution accessories
Clip in fasteners to be installed directly on 19” racks and on slotted MR mounting plates.
Reference: GCR.
GCR ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Adjustable ties
White BlackL ∅
minimum∅
maximum
M
Reference Use
LZ25100 LN25100 100 2.5 1.6 22
LZ25200 LN25200 200 2.5 1.6 49
LZ35150 LN35150 150 3.5 1.6 35
LZ35200 LN35200 200 3.5 1.6 49
LZ35300 LN35300 300 3.5 1.6 75
LZ46150 LN46150 150 4.6 1.6 36
LZ46200 LN46200 200 4.6 1.6 49
LZ48270 LN48270 270 4.8 1.6 73
LZ46390 LN46390 390 4.6 1.6 109
LZ76390 LN76390 390 7.6 4.7 108
To tighten and cut to size the adjustable ties. They facilitate wiring and save time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the tool. Can be used on the following models of ties: LZ25100 up to LZ46390. Ref.: MARK20, 21.
Tightening tools
Reference
MARK3 2.5 ÷ 4.8
Admissible width ties
Reference
MARK20 2.5 ÷ 4.8
MARK21 4.6 ÷ 7.6
Admissible width ties
03_101_107_EN.indd 10103_101_107_EN.indd 101 2/4/08 12:57:002/4/08 12:57:00
3/102
PLA Current distribution accessories
To use with soft materials: 7 mm Ø hole, or hard materials: 8 mm Ø hole. Ties are attached up to 9 mm width. Material: 6.6 nylon
Ref.: LOK01.
Stud
To attach one or two ties, mounted with a single screw. Material: 6.6 nylon. Allows for attaching ties from the entire range.
Tie fixing support
Reference A B Fixing screwAdmissible width
tiesC
KR6 12 18 9 M4 2.5 ÷ 4.8
KR8 14.5 25 12 M6 2.5 ÷ 7.6
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to 3.2 mm thick. Material: 6.6 nylon.
Locking clips
Reference
SFC1 6 3.2 1
SFC2 6 1 2
FigureMaximum width
panel mm∅ perforation
mm
SFC2 SFC1
Fig. 1 Fig. 2
03_101_107_EN.indd 10203_101_107_EN.indd 102 2/4/08 12:57:012/4/08 12:57:01
3/103
PLA Current distribution accessories
To transform normal ties into ties with fixing heads, introduce a tie into this head before closing it on the cable bundle. Material: 6.6 nylon.
Support heads
Reference A B Fixing screwAdmissible width ties
C
FH18 7.1 13.3 4 M4 2.5
FH30 9.5 17.9 4.7 M5 3.5
FH50 11.3 22.2 6.2 M6 4.7
Permits insertion of 1 tie from 4 points at a 90º angle. Attaches ties from the series LZ25100 up to LZ46390. Material: 6.6 nylon.
Self-adhesive support base
Reference A B C EAdmissible width
tiesD
MB3A 19.1 19.1 4.8 3.2 13.2 2.5 ÷ 3.5
MB4A 28.5 28.5 5.5 4 20.2 2.5 ÷ 4.8
To attach ties from any series. Material: 6.6 nylon.
Tie fixing support
Reference
LKC 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
adhesive support
03_101_107_EN.indd 10303_101_107_EN.indd 103 2/4/08 12:57:032/4/08 12:57:03
3/104
PLA Current distribution accessories
2 versions, fixed and graduated, ∅ from 5 to 25.4 mm. Material: black 6.6 nylon.
Fixing loop for tubes, hoses, etc.
Reference∅ A
min. - max.B D EC
NX1 5 3.5 1 6.2 13.7
NX3 8 3.9 1 9.4 20.5
NX5 12 3.9 1 9.4 24
NX8* 14.3 ÷ 15.8 4 1.3 12.6 32
NX11 17.4 ÷ 20 4 1.3 12.6 37
NX14 22.2 ÷ 25.4 4.3 1.5 16 45
*The NX8 model only has 3 adjustment holes.
NX 1-3-5 NX 8-11-14
Covers the head of the tie in its end, thus obtaining neater cabling. Material: 6.6 nylon.
Lateral tie fixing support
Reference
LKM/HE 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
03_101_107_EN.indd 10403_101_107_EN.indd 104 2/4/08 12:57:042/4/08 12:57:04
3/105
PLA Current distribution accessories
Insulating membrane glands made of PVC with entry that can be adjusted for cables.
Adjustable membrane glands
Reference Fig. Ø A Ø B* Ø C Ø D E FØ cable Tube
Capacity
ECPC-3 1 25 21.5 18 5 3.2 13 5 to 18 Pg 9 to 11
ECPC-5 1 33 29.5 26 5 3.2 20 5 to 26 Pg 9 to 16
ECPC-6 1 43 38.5 36 5 3.2 22 5 to 36 Pg 9 to 21
ECPC-9 2 70 63 60 28 3 20 28 to 60 Pg 21 to 48
ECPC-15 2 98 90 87 28 3 23 28 to 87 Pg 21 to 48
* Mounting perforation.
Fig. 1 Fig. 2
Ø A
Ø B
Small protective sleeves for cables coming out of tubes, as indicated in the instructions for MI BT 019. Made of flexible and durable PVC, in light grey colour.
Protective sleeves
Reference A Ø B Tube
PC-1 15.2 12.7 Pg 9
PC-2 18.6 16 Pg 11
PC-3 20.4 17.8 Pg 13.5
PC-4 22.5 19.8 Pg 16
PC-5 28.3 25.3 Pg 21
PC-6 37 33.6 Pg 29
PC-7 47 43 Pg 36
03_101_107_EN.indd 10503_101_107_EN.indd 105 2/4/08 12:57:042/4/08 12:57:04
3/106
PLA Current distribution accessories
Øexterior
SteelFlexible
steelPVC Insert Thread
Protective sleeves
Adjustable membrane
glandsPlain plugs
Adjustable membrane glands
Flexible steel with
PVC
Cables inserted*Ø interior To the perforationsTo the tubes
4 EC-1 to EC-7
Pg 9 15.2 12.7 12.4 12 11.1 6 2.5 - - 16 14 ECPC-3 to ECPC-6 PC-1 - -
ECN-5 to ECN-10
10 4 2.5 EC-2 to EC-7 EC-1
Pg 11 18.6 16 15.5 14.5 14.2 16 6 4 2.5 19 17.5 ECPC-5; ECPC-6 PC-2 EC-2 TC-1
25 ECN-5 to ECN-10 ECN-1
EC-3 to EC-7 EC-3
Pg 13.5 20.4 17.8 17.5 16.3 16 35 10 6 4 21 19.5 ECPC-5; ECPC-6 PC-3 ECPC-3 TC-2
ECN-5 to ECN-10
EC-4 to EC-7
Pg 16 22.5 19.8 18.7 18.5 17.6 50 16 10 6 23 21.5 ECPC-5; ECPC-6 PC-4 EC-4 TC-3
ECN-5 to ECN-10
EC-5 to EC-7 EC-5
Pg 21 28.3 25.3 24.7 23 23 70 25 16 10 29 27 ECPC-6 to ECPC-15 PC-5 ECPC-5 TC-4
ECN-6 to ECN-10 ECN-5
95 35 25 16 EC-6; EC-7 EC-6 TC-5
Pg 29 37 33.6 33.5 31 31 120 50 35 25 38 35.5 ECPC-9; ECPC-15 PC-6 ECPC-6 TCP-5
150 ECN-7; ECN-10 ECN-6
185 35 EC-7 EC-7
Pg 36 47 43 41.5 41 40.3 240 70 50 50 48 45.5 ECPC-9; ECPC-15 PC-7 ECN-7 TC-6
300 ECN-10
95 70 ECPC-9; ECPC-15
Pg 42 54 50 48 48 47 - 120 95 70 55 52.5 ECN-10 - - -
120 95 ECPC-9; ECPC-15
Pg 48 60 56 54.2 52.5 51.4 - 150 150 120 61 58 ECN-10 - - -
* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).
1 2 3 4
MODELS, DIMENSIONS AND REFERENCES
No. of conductors
Tubes HIMEL accessories to be coupled
Useful information about Pg tubes and HIMEL accessories to be coupled
Ø perforations to
Terminals especially designed for branching cables on plates; their main application is busbar connection.
BBH terminals are made of a tinned, hot cast copper alloy and are suitable for connecting to a conductor of copper or aluminium indistinctly (bimetal).
Bimetal BBH terminals
Reference
BBH-29 6-50 -
BBH-29C* 6-50 -
BBH-30 10-95 -
BBH-31 16-150 -
BBH-32 50-240 -
BBH-29D 6-50 6-50
BBH-29DC* 6-50 6-50
BBH-30D 10-95 10-95
BBH-31D 25-150 16-150
BBH-32D 95-240 5-240
Main section (mm2)
Bypass section (mm2) Reference
BBH-29P 6-50 -
BBH-29PC* 6-50 -
BBH-29DP 6-50 6-50
BBH-29DPC* 6-50 6-50
* Include terminal cover CBBH-29.
Main section (mm2)
Bypass section (mm2)
BBH-29 BBH-29D
BBH-29P BBH-29DP
Desig-nation
03_101_107_EN.indd 10603_101_107_EN.indd 106 2/4/08 12:57:052/4/08 12:57:05
3/107
ReferenceCable bypass section
(mm2)Plate thickness (mm) Figure
BPCH 516 1.5 to 16 5 2
BPCH 550 1.5 to 50 5 2
BPCH 5120 16 to 120 5 2
BPCH 1016 1.5 to 16 10 1
BPCH 1050 1.5 to 50 10 1
BPCH 10120 16 to 120 10 1
PLA Current distribution accessories
Base of safety terminals made of black matte self-extinguishing polyamide-6; terminal of brass MS-58
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that spreads the pressure out throughout the entire contact surface, avoiding the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the pressure exerted by the conductors cannot open the terminal and loosen the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap, avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of strips of any length. Service voltage: 500 V.
Sigma safety terminals
Reference
S.04 1 × 4 30 20 13 21 4
S.06 1 × 6 33 25 16 24 7
S.10 1 × 10 38 28 16 28 6
S.16 1 × 16 42 32 19 32 9
S.25/35 1 × 35 46 38 23 34 11
S.50 1 × 50 52 45 27 40 15
S.70 1 × 70 55 50 30 40 15
S.95/100 1 × 100 58 54 33 40 20
NOTE: each terminal accepts up to 2 conductors of the section indicated.
Sectionm/m2 A B C D E
Plate entry and bypass by cable.
Plate/cable terminals
1 2
03_101_107_EN.indd 10703_101_107_EN.indd 107 2/4/08 12:57:072/4/08 12:57:07
35590
7066
3/108
PLA Lighting accessories
Compact lamp
Specifications TensionPlugReference
Lamp fixed with a magnet
or on 35 mm symmetric LAM-75 220 V/16 A 220 V/50 Hz
DIN rail
Lamp fixed on a 35 mm
symmetric DIN rail LAC-75 220 V/16 A 220 V/50 Hz
Lamp fixed with a magnet
or on 35 mm symmetric LAM-75/120 120 V/15 A 120 V/60 Hz
DIN rail
Lamp fixed on a 35 mm
symmetric DIN rail LAC-75/120 120 V/15 A 120 V/60 Hz
Compact fluorescent lamps, designed especially for use in electronic enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.
c 200 V/16 A socket with earthing.
c Maximum ambient temperature 60 °C.
c Lighting output = 75 W bulb.
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm
c Lifespan: 10000 h.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Slimline lamp
Reference Plug Socket Approval
LAMS75 AC 230 V/16 A SCHUKO VDE
LAMX75 AC 230 V/- - VDE
LAMU75 AC 120 V/15 A USA UL
03_108_109_EN.indd 10803_108_109_EN.indd 108 5/3/08 11:29:425/3/08 11:29:42
3/109
PLA Lighting accessories
396
67
100
Dual lamp
1
2
3
4
Specifications Support fixing Figure Reference Tension
Motion-activated
Magnetic, using screws LAMDP 220 V/56 Hz
and/or (1) 35 DIN rail 1 LAMDP 120 120 V/60 Hz
On/off switch with the possibility Magnetic, via connection LAMIN 220 V/50 Hz
of door switch, screws and/or 35 DIN rail (1) 2 LAMIN 120 120 V/60 H
Mobile lamp, connection Adhesive or screws
LAMPO 220 V/50 Hz
via cable 3 LAMPO 120 120 V/60 Hz
Support for LAMDP, Adhesive or screws
LAMIN, LAMPO lamp 4 SOLAM
(1) DIN rail not provided..
Light fixtures designed especially for use in electronic enclosures with various possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or 120 V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model via cable.
c Degree of protection IP20.
c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
c Connection/disconnection switch.
c Terminal connection entry.
Incandescent lamp
Reference
LAI/OL 68
500
03_108_109_EN.indd 10903_108_109_EN.indd 109 5/3/08 11:29:485/3/08 11:29:48
3/110
PLA Natural ventilation accessories
To connect the inside of the enclosure with the exterior atmosphere and prevent condensation. Can be fixed onto the outside.
VM-25 VM-27
Ventilation devices
VM-25 For coupling to the outside of all polyester enclosures
VM-27
SpecificationsReference
03_110_117_EN.indd 11003_110_117_EN.indd 110 2/4/08 12:58:142/4/08 12:58:14
174
188 22 278 40
234
3/111
Plan size
A4 PP-A4
A5 PP-A5
Reference
Insulated
PLA Complementary accessories
PP-A models made of thermoplastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding DIN A3-A4 or A5-sized plans.
Document pocket
Ref.: PP-A5 Ref.: PP-A4
Dodge-type brass nuts designed to be incorporated into the bosses of PLM enclosures.
Expandable nuts
M5 PLM-43 and 54 TEX 5
M6 PLM-64 and 108 TEX 6
M8 For the back of the enclosure TEX 8
ReferenceSpecifications For attachment to enclosures
There is a set of slings to cover the most common enclosure or suite lifting needs.
Ref: ELS 1520.
c Table of dimensions indicating the maximum weight in kg anticipated for each enclosure or suite. The fields highlighted indicate the dimensional range of use planned for the lifting equipment ELS 1520.
(A) and (B) correspond, respectively, to the nominal height and width in mm of the enclosures or suites.
Lifting the enclosures
500 750 1000 1250 1500 1750 2000
1500 113 169 225 281 338 394 450
1200 94 141 188 234 281 328 375
1000 75 113 150 188 225 263 300
750 56 84 113 141 169 197 225
500 38 56 75 94 113 131 150
Width (B)Height (A)
TEX 8 TEX 6 TEX 5
03_110_117_EN.indd 11103_110_117_EN.indd 111 2/4/08 12:58:142/4/08 12:58:14
3/112
DLP distribution chassis set for modular equipment, to be coupled to all models of PLA enclosures.
c Distance of 40 to 85 mm, adjustable as needed by the customer, between the symmetric profile for equipment fixing and the interior protective cover.
c Rigid structure made of galvanised steel.
c Cover and frame insulating in self-extinguishing material in RAL-7032. Quick mounting, without the need for screws.
c System for identifying circuits included in the standard supply.
c Earth and neutral bypass terminal block, Ref.: RBLZ/21656 (included in standard supply).
c Possibility of installing plain mounting plates and covers to mount various material.
In enclosures with a closed base, Ref.: PLA… the 1500 height DLP chassis are coupled directly.
In models with open plinth-type bottom, Ref.: PLAZ should be ordered separately from the PTZ adapter plates (see footnote).
PLA Applications
* To be coupled to enclosures with open bottom, Ref.: PLAZ adaptor plates must be ordered separately, Ref.: PTZ 320 or PTZ 420, for 320 or 420 mm depth one-door enclosures.
PTZ 320/2P or PTZ 420/2P must be ordered for two-door enclosures.
MODELS, DIMENSIONS AND REFERENCES
No. of doors Individual chassis on two-door enclosures reference*Width (B)Height (A)
Total chassis reference*No. of rows
Automatic switch rail
Quantity No. of 18 mm modulesNo. of plates
For attachment to enclosures Distribution of rows
750 500 1 DLP 76 - 4 4 76 -
750 500 1 DLP 57 - 4 3 57 1
750 750 1 DLP 132 - 4 4 132 -
750 750 1 DLP 99 - 4 3 99 1
750 1000 2 - DLP 76 + DLP 76 4 + 4 4 + 4 152 -
DLP 57 + DLP 57 4 + 4 3 + 3 114 1 + 1
750 1250 2 - DLP 76 + DLP 132 4 + 4 4 + 4 208 -
DLP 57 + DLP 99 4 + 4 3 + 3 156 1 + 1
1000 500 1 DLP 114 - 6 6 114 -
1000 500 1 DLP 95 - 6 5 95 1
000 750 1 DLP 198 - 6 6 198 -
1000 750 1 DLP 165 - 6 5 165 1
1000 1000 2 - DLP 114 + DLP 114 6 + 6 6 + 6 228 -
DLP 95 + DLP 95 6 + 6 5 + 5 190 1 + 1
1000 1250 2 - DLP 114 + DLP 198 6 + 6 6 + 6 312 -
DLP 95 + DLP 165 6 + 6 5 + 5 260 1 + 1
1250 500 1 DLP 133 - 7 7 133 -
1250 500 1 DLP 114P - 7 6 114 1
1250 750 1 DLP 231 - 7 7 231 -
1250 750 1 DLP 198P - 7 6 198 1
1250 1000 2 - DLP 133 + DLP 133 7 + 7 7 + 7 266 -
DLP 114P + DLP 114P 7 + 7 6 + 6 228 1 + 1
1250 1250 2 - DLP 133 + DLP 231 7 + 7 7 + 7 364 -
DLP 114P + DLP 198P 7 + 7 6 + 6 312 1 + 1
1500 500 1 DLP 171 - 9 9 171 -
1500 500 1 DLP 152 - 9 8 152 1
1500 750 1 DLP 297 - 9 9 297 -
1500 750 1 DLP 264 - 9 8 264 1
1500 1000 2 - DLP 171 + DLP 171 9 + 9 9 + 9 342 -
1500 1000 2 - DLP 152 + DLP 152 9 + 9 8 + 8 304 -
1500 1250 2 - DLP 171 + DLP 297 9 + 9 9 + 9 468 1 + 1
1500 1250 2 - DLP 152 + DLP 264 9 + 9 8 + 8 416 1 + 1
DLP distribution system chassis
03_110_117_EN.indd 11203_110_117_EN.indd 112 2/4/08 12:58:182/4/08 12:58:18
85
40
2546
150
85
440
8585
40
85
40
45C-178C-mín.
40
16
C
3/113
Detail of the depth-adjustable rail using a graduated support included in the standard supply.
Covers that are quick fixing by pressure and removable using screwdriver.
Label for identifying circuits included in the standard supply.
FIG. 1
FIG. 2
Positioning the adjustable chassis at a depth of 25 mm.
* For enclosures with a transparent KT door, subtract 5 mm.
PLA Applications
(500)(1500)
DLP 171
(500)(1250)
DLP 133
(500)(1000)
DLP 114
(500)(750)
DLP 76
(750)(1500)
DLP 297
(750)(1250)
DLP 231
(750)(1000)
DLP 198
(750)(750)
DLP 132
(500)(1500)
DLP 152
(500)(1250)
DLP 114P
(500)(1000)
DLP 95
(500)(750)
DLP 57
(750)(1000)
DLP 165DLP 99
(750)(750)
(750)(1500)
DLP 264
(750)(1250)
DLP 198P
03_110_117_EN.indd 11303_110_117_EN.indd 113 2/4/08 12:58:182/4/08 12:58:18
3/114
Self-extinguishing plain cover to protect non-modular material.
c Colour RAL-7032.
c Easily machined.
c Quick mounting.
c 150 mm nominal height for 1 row.
2 mm thick mounting plate for fixing non-modular equipment, made of galvanised steel.
c Direct fixing to the adjustable support, which permits a depth adjustment of between 40 and 85 mm with respect to the cover.
c 150 mm nominal height for 1 row.
149
D
10×45°
E
PLA Applications
Plain cover
Mounting plate
Plate heightEnclosure width
(B)Reference D E
150 500 PMP500/DLP 361 149
150 750 PMP750/DLP 611 149
150 500 PMP500/2DLP 361 298
300 750 PMP750/2DLP 611 298
25 25
146
2113
D
To be coupled to nominal-width enclosures (B)
Reference D
500 CTL500/DLP 402
750 CTL750/DLP 652
500 CTL500/2DLP 402
750 CTL750/2DLP 652
03_110_117_EN.indd 11403_110_117_EN.indd 114 2/4/08 12:58:202/4/08 12:58:20
3/115
Earth or neutral bypass terminal blocks with insulating plinth.
Fixed to the back of the enclosure using the metal profile.
For the distribution in a single row of automatic switches with a total of 12 modules.
1 2
3 4
PLA Applications
Blanking plate
Bypass terminal blocks
* Included in standard supply.
Reference Number of terminals 3 section in mm2
RBLZ/21656* 2 16 mm2 + 5 6 mm2
RBLZ/21686 2 16 mm2 + 8 6 mm2
RBLZ/216146 2 16 mm2 + 14 6 mm2
RBLZ/216296 2 16 mm2 + 29 6 mm2
Distribution bars
No. of bars No. of poles per bar Reference Figure No.
1 12 BDS 1/12 1
2 6 BDS 2/6 2
3 4 BDS 3/4 3
4 3 BDS 4/3 4
Blanking plate of self-extinguishing insulating material for total or partial coverage of the windows for automatic switches. Easily cut to the desired size.
ATP6/DTM 108 6
ATP24/DTM 432 24
ATP/UND 1100 Cut to size
No. of modulesLength (mm)Reference
03_110_117_EN.indd 11503_110_117_EN.indd 115 2/4/08 12:58:222/4/08 12:58:22
3/116
System of very robust 19” metal racks, to be coupled to all versions of PLA enclosures with dimensions indicated on the following page.
c Fixed and pivoting racks, permitting direct installation (using standardised perforations) of all types of 19” modular switchgear.
c Fixing the racks on the upper part and the sides of the corresponding enclosure, using SPLA vertical profiles, which must be ordered separately from 750 mm height enclosures. See tables on the next page.
c Both the fixed and the pivoting racks can be installed as partial racks in enclosures that are larger than the foreseen normal. See tables on the next page.
c Maximum load: 3 kg per unit, with a maximum of 40 kg for pivoting racks.
c Finish: polyester-epoxy RAL-7032 paint.
c Pivoting racks with opening to 120º, 5 mm key-operated double bar lock.
➀ Fixed rack BRF 17PLA fixed using the set of two vertical profiles SPLA 100.
➁ Pivoting rack BRP 16PLA fixed using the set of two vertical profiles SPLA 100.
➂ Pivoting rack BRP 7PLA installed as a partial rack in enclosure. PLA 1074KT fixed using the set of two vertical profiles SPLA 100.
➂
➁
➀
PLA Applications
System of 19” racks
For 19” accessories, consult the VDI catalogue.
Ref.: SB/PLA.
19” rack support and trays for two-door enclosures
03_110_117_EN.indd 11603_110_117_EN.indd 116 2/4/08 12:58:232/4/08 12:58:23
31.7
5
485
465
450
55
750
77
300
420
12.7
44.4
544
.45
8.5 x 8.5
750
31.7
512
.7
44.4
544
.45
420
465
450
8.5 x 8.5
325
44
3/117
BRF racks prepared to be coupled to all 750 mm width PLA enclosure models.From the 750 mm height enclosures, the set of two vertical profiles SPLA, indicated in the table, must be ordered.
BRF...
SPLA...
BRP racks prepared to be coupled to all 750 mm width and 420 mm depth PLA enclosure models.From the 750 mm height enclosures, the set of two vertical profiles SPLA, indicated in the table, must be ordered separately.
BRP...
SPLA...
PLA Applications
19” fixed rack
* Can be installed in taller enclosures as a partial rack, using the vertical profiles that correspond to the height of the enclosure. In all cases, the SPLA vertical profiles must be ordered separately.(1) It can also be installed in the 1250 mm enclosures, on the 750 mm side, using the SBPLA profiles.
Height (A)
For attachment to enclosures
Width (1) (B)No. of units Reference rack Set of two profiles
500* 750 8 BRF 8PLA* -
750* 750 12 BRF 12PLA* SPLA 75
1000* 750 17 BRF 17PLA* SPLA 100
1250* 750 21 BRF 21PLA* SPLA 125
1500* 750 26 BRF 26PLA SPLA 150
19” pivoting rack
* Can be installed in taller enclosures as a partial rack, using the vertical profiles that correspond to the height of the enclosure. In all cases, the SPLA vertical profiles must be ordered separately.
Height (A)
For attachment to enclosures
Width (B)No. of units Reference rack Set of two profiles
500* 750 7 BRP 7PLA* -
750* 750 11 BRP 11PLA* SPLA 75
1000* 750 16 BRP 16PLA* SPLA 100
1250* 750 20 BRP 20PLA* SPLA 125
1500* 750 25 BRP 25PLA SPLA 150
19” fixed rack 19” pivoting rack
03_110_117_EN.indd 11703_110_117_EN.indd 117 2/4/08 12:58:242/4/08 12:58:24
11
1 3 4
10 8a-8b
5
6712
2
9
3/118
PLD and ZD polyester enclosures and plinths for LV electrical distribution
Self-ventilating polyester enclosures, prepared to directly incorporate fuse blocks for electrical distribution, conforming to DIN standards.
03_118_119.indd 11803_118_119.indd 118 21/2/08 11:53:2021/2/08 11:53:20
3/119
8b Detail of the enclosure with central profile joined to the left door and one single lock.
8a Detail of the profile joined directly to the enclosure and locks on the left and right doors.
2 Back with system of bosses with inclusions for fixing various materials.
1 Insulating bakelite mounting plates in black RAL-9005. To be coupled directly to the back of the enclosure.
7 Lower side view once the cable entry opening has been accessed.
12 Detail of the opening of the blanking plate of the auxiliar outlet.
5 PLD enclosures are designed to be installed directly on the floor or on ZD plinths.
4 Self-ventilating IP43 profile in standard supply. Possibility of IP54 by applying the synthetic rubber seal.
3 Expandable metal nuts to be included in the prepared housings in the enclosures for fixing of equipment, rails, etc.
11 View of the front crossbar dismounted, thus facilitating access to the interior of the enclosure.
10 Set of two metal supports for fixing the enclosure directly to the floor.
9 Detail of the easily removable interior hinge and bosses located at the back and on the door for fixing various materials.
6 Folding upper front cover, easily accessible from the interior of the enclosure.
03_118_119.indd 11903_118_119.indd 119 21/2/08 11:53:2321/2/08 11:53:23
3/120
PLD-ZDPolyester enclosuresSelf-ventilated IP43IP54 watertight (EN 60529)
Applications
c Self-ventilated polyester enclosures, prepared to directly incorporate fuse
blocks for electrical distribution.
c Extremely versatile for any type of assembly.
c Self-extinguishing and easily machined material.
c High resistance to mechanical impacts, temperature and corrosive
environments.
Construction specifications
c Resistance to the main chemical agents and corrosive atmospheres.
c Stabilised against UV rays.
c Reversible door opening to more than 180º in every case.
c Internal hinges easily removed.
c Back of enclosure with a system of bosses equipped with M8 and M10
inclusions allowing direct fixing of the mounting plates, bar supports and/or
various materials that offers great versatility for carrying out any type of
assembly.
c Removable front crossbar that enables better access to the interior of the
enclosure.
c Canopy and body of the enclosure of equal perimeter enabling enclosures to
be coupled both laterally and posteriorly.
PLD-86/0
Hot-press moulded fibreglass-reinforced polyester enclosure in grey RAL-7032 (able to withstand weather conditions).
03_120_137_EN.indd 12003_120_137_EN.indd 120 2/4/08 12:59:322/4/08 12:59:32
3/121
PLD-ZDPolyester enclosuresSelf-ventilated IP43IP54 watertight (EN 60529)
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c Degree of protection IP43/IK10.
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960°).
c Extreme operating temperatures from –50 a 150 ºC.
c Suitable for double insulation mounting conforming to IEC 60439-1
(EN 60439-1).
Basic composition
c Open top with canopy.
c Completely closed base.
c Reversible door opening to more than 180º.
c Three-point lock, handle operated without catch.
c Front crossbar easily removable.
Optional accessories
c Designed to be directly fixed to the ground or on a plinth ZD.
c Possibility of installing APLD mounting plates and BPLDN racks.
c Equipped with a system of bosses in the interior for fixing light fixtures.
c Possibility of IP54 when using a JED gasket.
E: Screws that connect the entry to the connection.
External dimensions (mm) Enclosures
Mounting plates APLD
Plinth ZD
Maximum No. of fuse blocks
Height(A)
Width (B)
Depth(C)
Reference DIN sizeNo. of doors
No. of locks
D
850 465 320 PLD-85/00 00 1 1 360 APLD-85 ZD-53/00 3 + E
850 590 320 PLD-86/0 0 1 1 495 APLD-86 ZD-63/0 4 + E
850 785 320 PLD-88/1 1 1 1 690 APLD-88 ZD-83/1 6 + E
850 1115 320 PLD-812/2 2 2 1 - APLD-812 ZD-123/2 9 + E
850 1115 320 PLD-812/2C 2 2 2 - APLD-812 ZD-123/2 9 + E
03_120_137_EN.indd 12103_120_137_EN.indd 121 2/4/08 12:59:332/4/08 12:59:33
3/122
FIG. 1
PLD-85/00; 86/0; 88/1 PLD-812/2; 812/2C
D
PLD-ZDPolyester enclosuresSelf-ventilated IP43IP54 watertight (EN 60529)
Dimensions (mm)
1 M10 inserts for installing plates and fuse holder plinths or other material.
2 M6 inserts for fixing mounting plates, rails in general and other material.
3 Bosses prepared for M8 inserts for fixing adjustable plate supports, Ref.: TEX 8.
4 Housings for installing floor fixing supports, Ref.: SPLD. Permit the insertion of M8 nuts, Ref.: TE/PLD-M8 for fixing various material.
5 Lock on right and left door on model PLD-812/2C.
Interior canopy prepared for bosses for inserting nuts, Ref.: TEX 6 for fixing auxiliary material, lighting, etc.
03_120_137_EN.indd 12203_120_137_EN.indd 122 2/4/08 12:59:332/4/08 12:59:33
3/123
PLD-ZD Composition accessories
Hot-press moulded fibreglass-reinforced polyester plinths, in grey RAL-7032 (able to withstand extreme weather conditions).
c Self-extinguishing material; easily machined; high resistance to impacts, temperature and corrosive environments.
c Partially ground embedded plinths prepared for direct fixing to the PLD enclosure.
c Folding front cover, accessible from the interior.
c Bosses on the rear panel prepared for inserting nuts, Ref.: TEX 6 for M6 screws, allowing for fixing of the the neutral plate, rails and other material.
c The sides have an auxiliary outlet with a passing diameter of Pg 36 (48 mm), fitted with a plug.
c Adjustable metal interior profiles in U and L for cable fixing.
c Possibility to cut out the interior part of the side for cable passage.
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Height (A)
External dimensions (mm)
Width (B) Depth (C)Reference To couple to enclosures
900 465 310 ZD-53/00 00 360 PLD-85/00
900 590 310 ZD-63/0 0 495 PLD-86/0
900 785 310 ZD-83/1 1 690 PLD-88/1
900 1115 310 ZD-123/2 2 - PLD-812/2; PLD-812/2C
DDIN size
ZD Plinths
Dimensions (mm)
ZD-53/00; 63/0; 83/1 ZD-123/2
03_120_137_EN.indd 12303_120_137_EN.indd 123 2/4/08 12:59:352/4/08 12:59:35
3/124
PLD-ZD Composition accessories
To be coupled directly to the door and the back of the enclosure, obtaining IP54.
c Manufactured in black synthetic rubber.
Sealing gasket
To couple to enclosures Reference
PLD-85/00 JED-85/00
PLD-86/0 JED-86/0
PLD-88/1 JED-88/1
PLD-812/2 and 2C JED-812/2
Direct-action standard lock, operated by a retractable handle.
Locks
CATCHES FOR LOCKS
Specifications ReferenceType of key
operation, Ref.:
Double bar lock LDB 5 TDB/PLD
Side triangle lock ∆ 8 mm LT-8 TT7/PLD
Lock with key type 405 TCL/PLD
Lock with reinforced key type
TLR/PLD
Manual lock TEM/PLD
Padlock
BCME/PL
Set of two metal supports for fixing the enclosure directly to the floor.
Ref.: SPLD.
KL
max.Enclosure reference
number
PLD-85/00 360 320 224
PLD-86/0 495 455 224
PLD-88/1 690 650 224
PLD-812/2 and 2C 1020 980 224
Mmax.
Floor fixing supports
03_120_137_EN.indd 12403_120_137_EN.indd 124 2/4/08 12:59:392/4/08 12:59:39
3/125
PLD-ZD Mounting accessories
To be coupled directly to the back of PLD enclosures.
c Insulating bakelite plates in black RAL-9005.
Possibility of depth adjustment. See notes on use of bosses 3 on page 3/122.
Mounting plates
ReferenceNo. of plates per
enclosure
Plate reference
D EFor attachment to enclosures Thickness
(mm)
PLD-85/00 1 APLD-85 356 304 5
PLD-86/0 1 APLD-86 481 429 5
PLD-88/1 1 APLD-88 676 624 5
PLD-812/2 and 2C 2 APLD-812* 448 396 5
* The reference includes the 2 plates.
Insulating rail in hot-pressed fibreglass-reinforced polyester, in grey RAL-7032.
c Direct lateral fixing to PLD enclosures.
c Possibility of directly fixing busbars.
Ref.: BPLDN.
Rack for fixing equipment
03_120_137_EN.indd 12503_120_137_EN.indd 125 2/4/08 12:59:402/4/08 12:59:40
3/126
PLD-ZD Current distribution accessories
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Adjustable ties
White BlackL ∅
minimum∅
maximum
M
Reference Use
LZ25100 LN25100 100 2.5 1.6 22
LZ25200 LN25200 200 2.5 1.6 49
LZ35150 LN35150 150 3.5 1.6 35
LZ35200 LN35200 200 3.5 1.6 49
LZ35300 LN35300 300 3.5 1.6 75
LZ46150 LN46150 150 4.6 1.6 36
LZ46200 LN46200 200 4.6 1.6 49
LZ48270 LN48270 270 4.8 1.6 73
LZ46390 LN46390 390 4.6 1.6 109
LZ76390 LN76390 390 7.6 4.7 108
To tighten and cut the adjustable ties to size. They facilitate wiring and save time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the tool. Can be used on the following models of ties: LZ25100 up to LZ46390. Ref.: MARK20, 21.
Tightening tools
Reference
MARK3 2.5 ÷ 4.8
Admissible width ties
Reference
MARK20 2.5 ÷ 4.8
MARK21 4.6 ÷ 7.6
Admissible width ties
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to 3.2 mm thick. Material: 6.6 nylon.
Locking clips
Reference
SFC1 6 3.2 1
SFC2 6 1 2
FigureMax. panel
thickness mm∅ perforation
mm
SFC2 SFC1
Fig. 1 Fig. 2
03_120_137_EN.indd 12603_120_137_EN.indd 126 2/4/08 12:59:422/4/08 12:59:42
3/127
PLD-ZD Current distribution accessories
To use with soft materials: 7 mm Ø hole, or hard materials: 8 mm Ø hole. Ties up to 9 mm in width can be coupled. Material: black 6.6 nylon.
Ref.: LOK01.
Stud
To attach one or two ties, mounted with a single screw. Material: 6.6 nylon. Allows for attaching ties from the entire range.
Tie fixing support
Reference A B Fixing screwAdmissible width ties
C
KR6 12 18 9 M4 2.5 ÷ 4.8
KR8 14.5 25 12 M6 2.5 ÷ 7.6
To transform normal ties into ties with fixing heads, introduce a tie into this head before closing it on the cable bundle. Material: 6.6 nylon.
Support heads
Reference A B Fixing screwAdmissible width ties
C
FH18 7.1 13.3 4 M4 2.5
FH30 9.5 17.9 4.7 M5 3.5
FH50 11.3 22.2 6.2 M6 4.7
03_120_137_EN.indd 12703_120_137_EN.indd 127 2/4/08 12:59:442/4/08 12:59:44
adhesive support
3/128
PLD-ZD Current distribution accessories
Permits insertion of 1 tie from 4 points at a 90º angle. Attaches ties from the series LZ25100 up to LZ46390. Material: 6.6 nylon.
Self-adhesive support base
Reference A B C EAdmissible width
tiesD
MB3A 19.1 19.1 4.8 3.2 13.2 2.5 ÷ 3.5
MB4A 28.5 28.5 5.5 4 20.2 2.5 ÷ 4.8
To attach ties from any series. Material: 6.6 nylon.
Tie fixing support
Reference
LKC 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
Covers the head of the tie in its end, thus obtaining neater cabling. Material: 6.6 nylon.
Lateral tie fixing support
Reference
LKM/HE 2.5 7.6 M5
Fixing screwAdmissible width
ties mm
03_120_137_EN.indd 12803_120_137_EN.indd 128 2/4/08 12:59:452/4/08 12:59:45
3/129
PLD-ZD Current distribution accessories
2 versions, fixed and adjustable, ∅ from 5 to 25.4 mm. Material: black 6.6 nylon.
Fixing loop for tubes, hoses, etc.
Reference∅ A
min. - max.B D EC
NX1 5 3.5 1 6.2 13.7
NX3 8 3.9 1 9.4 20.5
NX5 12 3.9 1 9.4 24
NX8* 14.3 ÷ 15.8 4 1.3 12.6 32
NX11 17.4 ÷ 20 4 1.3 12.6 37
NX14 22.2 ÷ 25.4 4.3 1.5 16 45
* The NX8 model only has 3 adjustment holes.
NX 1-3-5 NX 8-11-14
Insulated membrane glands made of PVC with entry that can be adjusted for cables.
Adjustable membrane glands
Reference Fig. Ø A Ø B* Ø C Ø D E FØ cable Tube
Capacity
ECPC-3 1 25 21.5 18 5 3.2 13 5 a 18 Pg 9 a 11
ECPC-5 1 33 29.5 26 5 3.2 20 5 a 26 Pg 9 a 16
ECPC-6 1 43 38.5 36 5 3.2 22 5 a 36 Pg 9 a 21
ECPC-9 2 70 63 60 28 3 20 28 a 60 Pg 21 a 48
ECPC-15 2 98 90 87 28 3 23 28 a 87 Pg 21 a 48
* Mounting perforation.
Fig. 1 Fig. 2
03_120_137_EN.indd 12903_120_137_EN.indd 129 2/4/08 12:59:462/4/08 12:59:46
Ø A
Ø B
3/130
PLD-ZD Current distribution accessories
Small protective sleeves for cables coming out of tubes, as indicated in the instructions for MI BT 019. Made of flexible and durable PVC, in light grey colour.
Protective sleeves
Reference A Ø B Tube
PC-1 15.2 12.7 Pg 9
PC-2 18.6 16 Pg 11
PC-3 20.4 17.8 Pg 13.5
PC-4 22.5 19.8 Pg 16
PC-5 28.3 25.3 Pg 21
PC-6 37 33.6 Pg 29
PC-7 47 43 Pg 36
Desig-nation
Ø exterior
SteelFlexible
steelPVC Insert Thread
Protective sleeves
Adjus. mem-brane glands
Plain plugsAdjustable mem-
brane glands
Flexible steel with
PVC
Cables inserted*Ø interior To the perforationsTo the tubes
1 2 3 4
MODELS, DIMENSIONS AND REFERENCES
No. of conductors
Tubes HIMEL accessories to be coupled
Useful information about Pg tubes and HIMEL accessories to be coupled
Ø perforations to
4 EC-1 al EC-7
Pg 9 15.2 12.7 12.4 12 11.1 6 2.5 - - 16 14 ECPC-3 al ECPC-6 PC-1 - -
ECN-5 al ECN-10
10 4 2.5 EC-2 al EC-7 EC-1
Pg 11 18.6 16 15.5 14.5 14.2 16 6 4 2.5 19 17.5 ECPC-5; ECPC-6 PC-2 EC-2 TC-1
25 ECN-5 al ECN-10 ECN-1
EC-3 al EC-7 EC-3
Pg 13.5 20.4 17.8 17.5 16.3 16 35 10 6 4 21 19.5 ECPC-5; ECPC-6 PC-3 ECPC-3 TC-2
ECN-5 al ECN-10
EC-4 al EC-7
Pg 16 22.5 19.8 18.7 18.5 17.6 50 16 10 6 23 21.5 ECPC-5; ECPC-6 PC-4 EC-4 TC-3
ECN-5 al ECN-10
EC-5 al EC-7 EC-5
Pg 21 28.3 25.3 24.7 23 23 70 25 16 10 29 27 ECPC-6 al ECPC-15 PC-5 ECPC-5 TC-4
ECN-6 al ECN-10 ECN-5
95 35 25 16 EC-6; EC-7 EC-6 TC-5
Pg 29 37 33.6 33.5 31 31 120 50 35 25 38 35.5 ECPC-9; ECPC-15 PC-6 ECPC-6 TCP-5
150 ECN-7; ECN-10 ECN-6
185 35 EC-7 EC-7
Pg 36 47 43 41.5 41 40.3 240 70 50 50 48 45.5 ECPC-9; ECPC-15 PC-7 ECN-7 TC-6
300 ECN-10
95 70 ECPC-9; ECPC-15
Pg 42 54 50 48 48 47 - 120 95 70 55 52.5 ECN-10 - - -
120 95 ECPC-9; ECPC-15
Pg 48 60 56 54.2 52.5 51.4 - 150 150 120 61 58 ECN-10 - - -
* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information consult the rules
03_120_137_EN.indd 13003_120_137_EN.indd 130 2/4/08 12:59:472/4/08 12:59:47
3/131
PLD-ZD Current distribution accessories
Base of safety terminals made of black matte self-extinguishing polyamide-6; terminal of brass MS-58
DIN17660); ring of tempered steel zinc dichromate; cap made of orange self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that spreads the pressure out throughout the entire contact surface, avoiding the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the pressure exerted by the conductors cannot open the terminal and loosen the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap, avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of strips of any length. Service voltage: 500 V.
Sigma safety terminals
Reference
S.04 1 × 4 30 20 13 21 4
S.06 1 × 6 33 25 16 24 7
S.10 1 × 10 38 28 16 28 6
S.16 1 × 16 42 32 19 32 9
S.25/35 1 × 35 46 38 23 34 11
S.50 1 × 50 52 45 27 40 15
S.70 1 × 70 55 50 30 40 15
S.95/100 1 × 100 58 54 33 40 20
NOTE: each terminal accepts up to 2 conductors of the section indicated.
Sectionm/m2 A B C D E
03_120_137_EN.indd 13103_120_137_EN.indd 131 2/4/08 12:59:482/4/08 12:59:48
3/132
ReferenceSection Cable bypass (mm2)
Plate thickness (mm) Figure
BPCH 516 1.5 to 16 5 2
BPCH 550 1.5 to 50 5 2
BPCH 5120 16 to 120 5 2
BPCH 1016 1.5 to 16 10 1
BPCH 1050 1.5 to 50 10 1
BPCH 10120 16 to 120 10 1
PLD-ZD Current distribution accessories
Terminals especially designed for branching cables on plates; their main application is busbar connection.
The BBH terminals are made of a tinned, hot cast copper alloy and are suitable for connecting to a conductor of copper or aluminium indistinctly (bimetal).
Bimetal BBH terminals
Reference
BBH-29 6-50 -
BBH-29C* 6-50 -
BBH-30 10-95 -
BBH-31 16-150 -
BBH-32 50-240 -
BBH-29D 6-50 6-50
BBH-29DC* 6-50 6-50
BBH-30D 10-95 10-95
BBH-31D 25-150 16-150
BBH-32D 95-240 5-240
Main section mm2 Bypass section mm2
Reference
BBH-29P 6-50 -
BBH-29PC* 6-50 -
BBH-29DP 6-50 6-50
BBH-29DPC* 6-50 6-50
* Include terminal cover CBBH-29.
Main section mm2 Bypass section mm2
BBH-29 BBH-29D
BBH-29P BBH-29DP
Plate entry and bypass by cable.
Plate/cable terminals
1 2
03_120_137_EN.indd 13203_120_137_EN.indd 132 2/4/08 12:59:482/4/08 12:59:48
35590
7066
3/133
PLD-ZD Lighting accessories
Compact lamp
Specifications TensionPlugReference
Lamp fixed with a magnet or
on 35 mm symmetrical LAM-75 220 V/16 A 220 V/50 Hz
DIN rail.
Lamp fixed on a 35 mm
symmetrical DIN rail. LAC-75 220 V/16 A 220 V/50 Hz
L amp fixed with a magnet or
on 35 mm symmetrical LAM-75/120 120 V/15 A 120 V/60 Hz
DIN rail.
Lamp fixed on a 35 mm
symmetrical DIN rail. LAC-75/120 120 V/15 A 120 V/60 Hz
Compact fluorescent lamps, designed especially for use in electronic enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.
c 200 V/16 A socket with earthing.
c Maximum ambient temperature 60 °C.
c Lighting output = 75 W bulb.
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm
c Lifespan: 10000 h
c Carcasa de plástico UL94 V0.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Slimline lamp
Reference Plug Socket Approval
LAMS75 AC 230 V/16 A SCHUKO VDE
LAMX75 AC 230 V/- - VDE
LAMU75 AC 120 V/15 A USA UL
03_120_137_EN.indd 13303_120_137_EN.indd 133 2/4/08 12:59:502/4/08 12:59:50
396
67
100
500
3/134
PLD-ZD Lighting accessories
Dual lamp
1
2
3
4
Specifications Support fixing Figure Reference Tension
Motion-activated
Magnetic, using screws LAMDP 220 V/56 Hz
and/or (1) 35 DIN rail 1 LAMDP 120 120 V/60 Hz
On/off switch with the possibility Magnetic, using screws LAMIN 220 V/50 Hz
of connecting door switch and/or (1) 35 DIN rail 2 LAMIN 120 120 V/60 H
Mobile lamp, connection Adhesive or screws
LAMPO 220 V/50 Hz
via cable 3 LAMPO 120 120 V/60 Hz
Support for LAMDP, LAMIN, Adhesive or screws
LAMPO lamp 4 SOLAM
(1) DIN rail not provided.
Light fixtures designed especially for use in electronic enclosures with various possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or 120 V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model via cable.
c Degree of protection IP20.
c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
c Connection/disconnection switch.
c Terminal connection entry.
Incandescent lamp
Reference
LAI/OL 68
03_120_137_EN.indd 13403_120_137_EN.indd 134 2/4/08 12:59:512/4/08 12:59:51
3/135
To connect the inside of the enclosure with the exterior atmosphere and prevent condensation. Can be fixed onto the outside.
VM-25 VM-27
Ventilation devices
VM-25 For coupling to the outside of all polyester enclosures
VM-27
SpecificationsReference
PLD-ZD Natural ventilation accessories
03_120_137_EN.indd 13503_120_137_EN.indd 135 2/4/08 12:59:532/4/08 12:59:53
174
188 22 278 40
234
TEX 8 TEX 6 TEX 5
3/136
PLD-ZD Complementary accessories
PP-A models made of thermoplastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding DIN A3-A4 or A5-sized plans.
Document pocket
Ref.: PP-A5 Ref.: PP-A4
Plan size
A4 PP-A4
A5 PP-A5
Reference
Insulated
Expandable metal nuts to be included in the prepared housings in the enclosures for fixing of equipment, rails, etc.
Specifications Reference
M5 TEX 5
M6 TEX 6
M8 TEX 8
Expandable nuts
03_120_137_EN.indd 13603_120_137_EN.indd 136 2/4/08 12:59:532/4/08 12:59:53
3/137
One of the main applications is the LV distribution. For this reason, they are prepared for the incorporation of fuse blocks, insulators and busbars.
PLD enclosure equipped with:
c 3F + N 50 × 10 copper busbar.
c Floor fixing supports SPLD.
c Prepared for installing fuse block (not included).
c Triangle lock.
PLD enclosure equipped with:
c Plinth ZD.
c 3F + N 50 × 10 copper busbar.
c Prepared for installing fuse block (not included).
c Triangle lock.
(Bases not included)
Reference Dimensions (mm) Capacity, vertical s/c III*
PLZD-85/B 1720 × 465 × 320 3+E
PLZD-86/B 1720 × 590 × 320 4+E
PLZD-88/B 1720 × 785 × 320 6+E
PLZD-812/B 1720 × 1115 × 320 9+E
PLZD-812-C/B 1720 × 1115 × 320 9+E
E: screws that connect the entry to the connection.
Distribution enclosures in BT
PLD-B enclosures
PLZD-B enclosures
E: screws that connect the entry to the connection.
Reference Dimensions (mm) Capacity, vertical s/c III*
PLD-85/B 850 × 465 × 320 3+E
PLD-86/B 850 × 590 × 320 4+E
PLD-88/B 850 × 785 × 320 6+E
PLD-812/B 850 × 1115 × 320 9+E
PLD-812-C/B 850 × 1115 × 320 9+E
PLD-ZD Applications
SPECIAL ARTICLES ON REQUEST
03_120_137_EN.indd 13703_120_137_EN.indd 137 2/4/08 12:59:562/4/08 12:59:56