residual studies

Post on 22-Feb-2016

36 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

RESIDUAL STUDIES. ANALISYS UNDER DIFFERENT SITUATIONS. Residual comparison between old ntupla (TOTdebug3.root, gauss v25r12) and new geometry new gauss (v30r4) just first pad selected (M2-M3 are rebinned 4 also in the next slides). OLD. NEW. - PowerPoint PPT Presentation

TRANSCRIPT

RESIDUAL STUDIES

ANALISYS UNDER DIFFERENT SITUATIONS

13/05/2008 1Simone Brusa, INFN-Ferrara

Residual comparison between old ntupla (TOTdebug3.root, gauss v25r12) and new geometry new gauss (v30r4) just first pad selected (M2-M3 are rebinned 4 also in the next slides)

13/05/2008 Simone Brusa, INFN-Ferrara 2

OLD

NEW

COMPARISON BETWEEN OLD NTUPLA GAUSS V25R12 & THE SAME NTUPLA REPROCESSED USING THE LAST VERSION OF

AllineaBrunel (not big pad)

29/04/2008 Simone Brusa, INFN sezione di Ferrara 3

OLD

REPR

OC

ESSED

What is it changed?Did we changed the selection Algorithm?

Brunel ntupla reprocessed with last version of root`s macro, no big pad.

Old digi reprocessed under new Brunel version (v32r1), same root`s macro

13/05/2008 Simone Brusa, INFN-Ferrara 4

Response: no!

Selected just the first pad for both.

13/05/2008 Simone Brusa, INFN-Ferrara 5

From the previous slides. we can see that the results obtained using the last version of AllineBrunelCTalk, are comparable.It`s even better than before, remember that we are using the right pad size (different from TDR) and a new binning.

Now the question is:why the residual distributions are so bad now?It depends on the geometry?No (see the plot)!

OLD GEOMETRY, NEW GAUSS V30R4

New geometry, old Gauss v25r12, just first pad selected

13/05/2008 Simone Brusa, INFN-Ferrara 6

BOTH NEW GEOMETRY & FIRST PAD SELETCTED GAUSS V25R12 GAUSS V30R4

13/05/2008 Simone Brusa, INFN-Ferrara 7

They are comparable!B is on for both! Is it the source of the problem?

RESUMING TABLEB field Geomet

ryGauss Boole Brunel Root `s

macroResults Slide #

On New New New New New Bad M4 2

On Old New New New New Bad M4 5

Off Old Old Old Old From Saint Nectaire

OK 2

Off Old Old Old Old New OK 3

Off Old Old Old New New OK 4

On New Old Old Old New Bad M4 6

Off New New New New New Ok Next slide

13/05/2008 Simone Brusa, INFN-Ferrara 8

New geometry, new Gauss, Boole & Brunel, just first pad selected & Boff (172k muon

tracks reconstructed)

13/05/2008 Simone Brusa, INFN-Ferrara 9

Conclusions & to do 1/2• Seems that the source of our problem is a bad

pattern recognition with the magnetic field on.• The selection used is just the first pad;• Respect to the last report, I found a my mistake

in the code and the Z correction doesn`t remove the jumps in the Xpad-XMChit distribution between adjacent rows & columns of chambers

• I would to check the results one more time in order to guarantee them.

13/05/2008 Simone Brusa, INFN-Ferrara 10

Conclusions & to do 2/2

• Next step will be run Brunel setting properly the flag B field to false (should not change the results);I already submit the jobs;

• Remove the cut on the mchits inside the pads;• Modify the pattern recognition algorithm to work

properly also with B on;• Do you have any suggestion?(example look at the

center of the B field instead on IP, …)

13/05/2008 Simone Brusa, INFN-Ferrara 11