ref601 iec tpres 1mdl07202-yn enc
Post on 08-Apr-2015
78 Views
Preview:
TRANSCRIPT
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
B
Feeder Protection REF601
Technical Presentation
ABB LtdDistribution Automation
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
IntroductionIntroduction
Feeder Protection REF601
Application examplesApplication examples
Hardware and optionsHardware and options
FunctionalityFunctionality
Mechanical designMechanical design
Front panel HMIFront panel HMI
ConclusionsConclusions
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Introduction
IntroductionINSERT PICTURE
HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Feeder Protection REF601
REF601 is a numerical feeder protection relay, designed for the protection and control of utility and industrial power systems, in primary and secondary distribution network
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Feeder Protection REF601
Designed for over-currentand earth-fault protection
Main application area: Cables, Lines or transformer feedersin solidly earthed, resistance earthed or isolated distribution networks
Brings the advantages of Rogowski coil current sensors to medium-voltage applications
The relay for integrated offering of VD4/ HD4 circuit breakers with protection and sensors
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Application
examples
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 in directly earthed network
Main protection: 3I>, I0>
Necessary curves for primary / secondary distribution
IEC NI, VI, EI, LI
Special RI
Dual mode of earth current measurement
Internal calculationExternal CBCT input
Protection blocking by second harmonic measurement for stability during magnetizing inrush of transformers
REF601 applied for a feeder in an solidly earthed distribution network
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 in isolated network
REF601 applied for a feeder in an resistance earthed or isolated distribution network
Main protection: 3I>, I0>
Necessary curves for primary / secondary distribution
IEC NI, VI, EI, LI
Special RI
Dual mode of earth current measurement
Internal calculation
External CBCT input
Protection blocking by second harmonic measurement for stability during magnetizing inrush of transformers
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Hardware
and options
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Hardware
Power supply Wide range 24 - 240 V DC / AC
Analogue inputs3 Sensor inputs for phase
1 CT input for E/F
Binary input / output4 binary inputs
6 binary outputs
Communication (optional)MODBUS RTU on RS485
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Analog InputThree phase sensor inputs with rated transformation ratio :
150mV/250A for 50Hz
180mV/250A for 60Hz
Note : These inputs are not compatible with conventional 1 A / 5 A CT’s.
Four selectable nominal primary current values- 40/80/250/1250A
Programmable sensor calibration factor for higher over-all accuracy
One earth current input (I0) suitable for conventional 1 A core balance CT
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Binary input
Four galvanically isolated binary input for
Remote trip
Remote reset
Remote close
Remote open
Wide operative voltage range (24 – 240 V AC/DC) for binary input
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Binary output Two trip outputs
Trip 1 : Normally closed output which opens for 200ms for tripping CB
Trip 2 / Breaker Open : Normally open output which closes for 200 ms for tripping CB
One Breaker close contact
Two signal outputsPhase over-current trip
Earth over-current trip
One Unit ready / IRF contact
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Power supply
Universal input power supply with 24 – 240V AC / DC range
-30% to +20% tolerance for DC
-15% to +10% tolerance for AC
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Functionality
Functionality
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Protection functions
503I>>>Non Directional Over-current, High set ( DMT or Inst. )
683I2f>3-phase Transformer Inrush detector50N/51NI0>>Non Directional Earth-fault, High-set ( DMT or Inst. )51NI0>Non Directional Earth-fault, Low-set, ( DMT or IDMT )
50/513I>>Non Directional Over-current, High set ( DMT or Inst. )
513I>Non Directional Over-current , Low set ( DMT or IDMT )ANSIIEC 60617Protection functions
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Breaker Control
Dedicated push - buttons for local breaker control
Dedicated binary Inputs for remote breaker control
Optimum duty outputs for breaker control
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 MeasurementsRMS value of fundamental component
Default displayMost loaded Phase - Amps
Earth current - % nominal
Selectable displayPhase currents - Amps
Earth current - % nominal
ORPhase currents - % nominal
Earth current - % nominal
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Recorded dataCurrent values for I1, I2, I3 and I0 are recorded for two trip events
Record length of 15 samples @ one sample/cycle
5 samples pre-trip and 10 samples post-trip
Trip counterPhase trip and Earth trip counters –cannot be reset
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 EventsLast five events
Events triggered by protection trip, Relay fault, 4xBI
Event log containsAnalog values of I1, I2, I3 and I04xBI status , 4xBO status, Unit Ready
status and fault code
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 SafetyContinuous monitoring of
Memory circuits (RAM, ROM, EEPROM)
Internal supply voltages
Hardware and software configuration
Indication by Ready LED
Protection blocking on critical internal relay failure to avoid unwanted trip
Non-volatile memory for setting values and fault recorded information
Operation indications and LED’s showing status at the fault
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Access Control and traceability
Role based access control
Three level accessOperator
Setting
Admin
Administrator programmable password
Version informationProduct type, Software version
Model name
Nominal primary current
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Test functions
Hardware testLCD test
Keyboard test
LED test
BI test
BO test
Serial EEPROM
Trip output test
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
CommunicationINSERT PICTURE
HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Communication option
Communication on MODBUS RTU protocol
RS 485 port for communication
Selectable data transfer rates 2400 … 38400 baud
RS 485 Serial Bus
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Mechanical
design
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Mechanical Dimensions
Compact dimensions for new and retrofit installations
Height : 160 mm
Width : 130 mm
Depth : 101 mm
Weight : 1,2 Kg
Ingress protectionIP 42 on front when panel mounted
IP 20 on Top, Side, Bottom, Rear
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Mechanical Dimensions
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Circuit Breaker Mounting
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Panel Mounting
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Front panel HMI
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Front panel HMI
Navigation buttons
ESC button
CB Control buttons
2 x 16 characterLCD Display
Phase fault and Earth Fault Indications
Three dedicated LEDs: Ready, Start,Trip
Enter button
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
ConclusionsINSERT PICTURE
HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Product summarySensor input for phase currentExternal CBCT input for earth currentInternal calculation of earth currentThree-stage overcurrent protectionTwo-stage earth-fault protectionMagnetizing inrush detectionControl of circuit breakerLocal and remote controlFive event logsTwo fault records of analogue valueNon-resettable trip counterOn-line measurementsComprehensive local HMIUniversal auxiliary supply ratingCircuit breaker or panel mountingOptional Modbus communicationNon-volatile memoryAccess controlSelf-supervisionBuilt-in test funcionality
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Selection and ordering data
FFeeder protection with control
Series identity3
2
1
Sr. No.
60_ series
Main applicationRE_ series relayBrand identity
RE
601
Description
R E F 6 0 1 B A A 4 6 A A 1 X A
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Selection and ordering data
644 BI + 6 BOBinary Input / Output
AA3 sensor and ground CT
6
5
4
Sr. No.
Analog Input / OutputIECStandard
B
Description
R E F 6 0 1 B A A 4 6 A A 1 X A
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Selection and ordering data
Serial communicationAWith RS 485
124 – 240V AC / DCPower supply
AModbus RTUNNone
9
8
7
Sr. No.
Communication protocolNone N
Description
R E F 6 0 1 B A A 4 6 A A 1 X A
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
REF601 Selection and ordering data
Vacant digitXVacant
AVersion 1.011
10
Sr. No.
Version
Description
R E F 6 0 1 B A A 4 6 A A 1 X A
©20
08 A
BB L
imite
d1M
DL0
7202
-YN
Rev
.a
Please visit ourwebsite for the latest product information
www.abb.com/substationautomation
INSERT PICTURE HERE !
SIZE: 8.5 X 19.05 CM
NOTE! THE GREEN
BACKGROUND COLOUR IS ONLY TO INDICATE THE SIZE
OF THE PICTURE
top related